Loading...
Plans BU P2010-00195 H & M 9524 SW WASHINGTON SQUARE RD H08 September 14, 2010 RE: TENANT IMPROVEMENT Project Information Building Permit: BUP2010-00195 Construction Type: 2-B Address: 9424 SW Washington Sq. Occupancy Type: M Area: 19503 Sq. Ft. Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2007 edition; 2007 Oregon Fire Code. Provide the following items prior to issuance of this permit. 1) All improvements made to the building shall be inspected prior to covering. 2) Make approved set of plans available for all inspections. 3) A total of 25% of the cost of the project shall go towards removing architectural barriers (accessibility). 4) Suspended ceiling to be installed as per ASCE 7 or Oregon State Interpretation. 5) All framing shall conform to accepted engineering standards. FIRE LIFE AND SAFETY/ GENERAL The main exterior door or doors are permitted to be equipped with key-operated locking devices from the egress side provided: 1. The locking device is readily distinguishable as locked, 2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background. (Sec. 1008.1.8.3) All exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (Sec. 1008.1.8) Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. (Sec. 1011.1) Exit signs shall be illuminated at all times and shall be provided with a second source of power that will provide 1 '/% hours of illumination in case of primary power loss. (Sec. 1006.3) FYI -Additional exit signs may be required by the city field inspector to clearly indicate the path of egress. The means of egress shall be provided with illumination of not less than 1 foot candle at the floor level anytime the building is occupied. The means of egress illumination, when two exits are required, shall be provided with a second source of power in case of primary power loss. (Sec. 1006.2) Portable fire extinguishers shall be installed in new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4, and S occupancies. (OFC Sec. 906) American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC, which may not include all of the requirements of the ADA. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. (106.3.1 OSSC) Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy (109.1 OSSC) Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Mark VanDomelen Building Official (503) 718-2448 markv @tigard-or.gov RmStructural Engineers Robinson Principals Meier Peter Robinson,S.E. Juilly & Associates Japan E.Haines,S.E. 711/& REcVED CITY OF Washin ton Square g 9585 S.W. Washington Square Portland, OR 97223 Structural Calculations for New Storefront Description Page Project Description 1 Seismic Design Category 2 Building Loads 3 Built-up Box Beams 4-7 r Lateral Design 8-10 Built-u p Box Columns 11-12 Diagonal Braces 13-14 Seismic Output File 15 \) 1$113461, Prepared for: Arc1i-:,ects N August 13, 2010 ' RM3 Jab#10164 Exp. 12/31/2010 103 Linden Avenue So.San Francisco,CA 94080 (650)871.2282 FAX(650)871.2459 www rmjse.com Sheet 1 Rmj H&M Washing Square, OR RMJ Job# 10164 Project Description: This project involves providing support for an interior mall storefront for the H&M store at the above referenced location. Built-up box beams and columns provide gravity support at the entry and displays. Diagonal braces provide lateral support against out-of-plane loads. Storefront walls provide lateral support against in- plane loads. Design is in accordance with the 2006 edition of the International Building Code. lii Sheet 1 Rm j H&M Washington Square, OR RMJ Job# 10164 Project Description: This project involves providing support for an interior mall storefronts for the H&M store at the above referenced location. Built-up box beams and columns provide gravity support at the entry and displays. Diagonal braces provide lateral support against out-of-plane loads. Storefront walls provide lateral support against in- plane loads. Design is in accordance with the 2006 edition of the International Building Code. RMJ #41 103 Linden Avenue Washington Square South San Francisco, CA 94080 9585 S.W. Washington Square (650) 871-2282 Job No.: 10164 Date: 6/1/10 Fax: 871-2459 By: mas Page: 1 Find the Seismic Design Category (SDC) Project Location: Portland, OR Latitude: 45.45 Longitude: -122.78 Soil Classification: D Table 1613.5.2 & Section 1613.5.2 Ocupancy Category: II Table 1604.5 Information from U.S. Geological Survey Website uaiLQ,u§oacaL ± pif research hazma s Ss= 3.943 g S1= 0.341 g Fa= 1.12 Table 1613.5.3(1) Fv= 172 Table 1613.5.3(2) SMS= 1.06 g (Equation 16-37) SM1= 0.59 g (Equation 16-38) Sips= 0.708 g (Equation 16-39) SDI= 0.391 g (Equation 16-40) Seismic Design Category (SDC): RMJ 103 Linden Avenue Washington Square South San Francisco, CA 94080 9585 S.W. Washington Square (650) 871-2282 Job No.: 10164 Date: 6/1/10 Fax: 871-2459 By: mas Page: Interior Storefront Soffit Loads Framing 5/8" Gypboard 2.7psf x 3.4' 9.18 plf Horiz. 362S162-33 DIAG. at 16" o.c. 4.42 plf Vert. 362S162-33 DIAG. at 16" o.c. 10.00 plf Diag. 362S162-33 DIAG. at 16" o.c. 1 .54 plf Built-Up Box Beam 5.22 plf Sign Box 10.00 plf Misc. 3.30 plf Total 43.7 plf Use 80.0 plf Live Loads Live Load 10 psf x 2'-0" 20.0 plf Total Load 100.0 pit pad load, 80.0 plf used in determining lateral loads. These loads are loads per foot for EACH built-up box beam at Interior storefront. RNAJ #114 103 Linden Avenue Washington Square South San Francisco, CA 94080 9585 S.W. Washington Square (650) 871-2282 Job No.: 10164 Date: 6/1/10 Fax: 871-2459 By: mas • Page: L\ Built-up Box Beam at Entry Maximum Length= 27.5 ft 330 in Maximum Moment=w x L2/8 = 9,453 ft-lb = 113,438 in-lb Built-Up Section 2 -1200S162-97 Studs & 2-362T150-33 Tracks Only 2-1200S162-97 used in design of box beam lx (net) = 53.93 in., Moment of Box Beam Ma= 266,887 in-lb (Prop86) Ma= 318,840 in-lb (SSMA Catalog) Mmax= 113,438 in-lb <Ma= 266,887 in-lb CHECK OK! Deflection A = 5wL4 = 0.82 in 384E1 L Aa= = 1.38 in 240 DEFLECTION OK! 1,7 Copyrigbt (C) - SURE-TIE, INC.. - 1802-98, All Rights Reserved. l2003162-97 � DIMENSIONS / PHYSICAL PROPERTIES / Web (A' ) = 12.000 in. Punchout = 1.500 in. KLX = 144.00 in. Fy = 50.000 ksi (abar) = 11.898 in. Spacing = 24.000 in. Fya-AXIAL = 50.000 ksi (a ) = 11.491 in. Type = CONFORMING Fya-BEND = 50.000 ksi Flanges (B' ) = 1.625, 1.625 in. Thickness = 0.1017 in. KLY = 48.00 in. Fu = 85.000 ksi (bbar) = 1.523, 1.523 in. h/t Web = 118.0 Fu/Fy = 1.300 (b ) = 1.116, 1.118 in. wit Flanges = 11.0, 11.0 Lip (C' ) = 0.500 in. Bearing Width = 1.500 in. KLT = 48.00 in. E = 29,500 ksi (cbar) = 0.049 in. (c ) = 0.205 in. Radius OR ) = 0.1530 in. KIB = 144.00 in. G = 11,300 ksi (r ) = 0.2039 in. (u ) = 0.3200 in. Net/Gross Section Used for Capacity = DET WALLBOARD PARAMETERS : Stud Spacing = 16.00 in. q-bar-o = 0.000 ksi Gamma = 0.000 in./in. Fastener Spacing = 12.00 in. DEFLECTION LIMIT / MOMENT COEFFICIENTS : Deflection = L/360 Cmx = 1.000 Cmy = 1.000 Ey = 0.000 in. Ex = 0.000 in. ____ GROSS / NET SECTION PROPERTIES BASED ON 1996 AISI SPECIFICATIONS (BOXED Configuration) ____ __ Area Gross = 3.15I io^2 Area Net = 2.846 iu^2 Ix Gross = 53.942 in^4 Bu Gross = 8.900 io^3 Rx Gross = 4.137 in. x-bar = 1.625 in. Ix Net = 53.885 io44 Sx Net = 8.981 iu^3 Rx Net = 4.351 in. Iy Gross = 8.009 iu^0 Sy Gross = 3.698 iu9 @y Gross = 1.381 in. y-bar = 6.000 in. Iy0ot = 5.302 iu^A Sy Net = 3.263 iu^3 Ry Net = 1.365 in. m = 0.000 in. J = 20.286648 ioq xo = 0.000 in. Cw = 9.8878 io^6 Bw = - 3.1648 io^5 Bf = 6.0760 io^5 BI = 4.1031 io45 j = 0.5837 in. ro = 4.362 in. Beta = 1.000 Ixx/Iyy Required = 0.000/ 0.000 io^A ALLOWABLE LOADS Lateral Loads (X/Y) = 0.00/ 0.00 psf Overall Nominal Failure Load = 65,168 lbs. Overall Allowable Axial Load = 36,204 lbs. Omega = 1.80 Nominal Y-Axis Moment Capacity = 99,442 in-lbs Allowable Y-Axis Moment Capacity = 50,546 in-lbs Omega = 1.67 Nominal Cap. (4(0) in Tension) = 99,442 in-lbs Allowable Cap. (Web in Tension) = 58,546 in-lbs Iyy Effective at Comp. Yield = 1.602 io^4 Min. Syy Effective at Comp. Yield = 1.989 in^3 Min. Nominal X-Axis Moment Capacity = 405,701 in-lbs &llowable X-Axis Moment Capacity = 266,887 in-lbs Omega = 1.67 Iox Effective at Comp. Yield = 53.902 io^A Buz Effective at Comp. Yield = 0.980 iu^3 Allow. Load Considering Lat. Load (Comp/Tension) = 36,204/ 85,212 lbs. Lat. Load Moments (X/Y) = 0/ 0 in-lbs Allowable Shear Load on Unreinforced Web = 13,480 ibm. > Actual Shear Load = 0 lbs. Allowable End One-Flange Loading Reaction = 3,909 Ibu. > Actual End Reaction = 0 lbs. Izx for Deflection Determination = 53.942 io^4 - at Current Stress Level in Section of 11,089 psi Iyy for Deflection Determination = 1.602 io^A - at Maximum Stress Level in Section of 50,000 psi PROP86, Varoioo 5.00 - BM/ & ASSOCIATES Printed On 06-0I-20I0 at 10:08:40 Page 1 of 1 RMJ 7I-AM 103 Linden Avenue Washington Square South San Francisco, CA 94080 9585 S.W. Washington Square (650) 871-2282 Job No.: 10164 Date: 6/1/10 Fax: 871-2459 By: mas Page: c. Built-up Box Beam at Display Maximum Length= 14.25 ft 171 in Maximum Moment=w x L2/8 = 2,538 ft-lb = 30,459 in-lb Built-Up Section 2 -800S162-54 Studs & 2-362T150-33 Tracks Only 2-800S162-54 used in design of box beam lx (net) = 11.472 in4 Moment of Box Beam Ma= 83,168 in-lb (Prop86) Ma= 83,680 in-lb (SSMA Catalog) Mmax= 30,459 in-lb <Ma= 83,168 in-lb CHECK OK! Deflection A = 5wL4 . 0.28 in 384E1 L da = = 0.71 in 240 DEFLECTION OK! Copyright (C) - SURE-TIE, INC. - 1992-98, All Rights Reserved. 000S162-54 --------- --------------- ____ DIMENSIONS / PHYSICAL PROPERTIES : Web (A' ) = 8.000 in. Punchout = 1.500 in. DIX = 144.00 in. Fy = 50.000 ksi (bar) = 7.943 in. Spacing = 24.000 in. Fya-AXIAL = 50.000 ksi (a ) = 7.717 in. Type = CONFORMING Fya-BEND = 50.000 ksi Flanges (B' ) = 1.825, 1.625 in. Thickness = 0.0566 in. KLY = 48.00 in. Fu = 65.000 ksi ()taz) = 1.568, 1.560 in. h/t Web = 136.3 Fu/Fy = 1.300 (b ) = 1.342, 1.842 in. w/t Flanges = 23.7, 23.7 Lip (C' ) = 0.300 in. Bearing Width = 1.500 in. DLT = 48.00 in. E = 20,500 ksi (obaz) = 0.472 in. (c ) = 0.359 in. Radius OR ) = 0.0809 in. KLB = 140.00 in. G = 11,300 ksi (r ) = 0.1122 in. (u ) = 0.1777 in. Net/Gross Section Used for Capacity = NET WALLBOARD PARAMETERS : Stud Spacing = 16.00 in. q-bar-o = 0.000 ksi Gamma = 0.000 in./in. Fastener Spacing = 16.00 in. DEFLECTION LIMIT / MOMENT COEFFICIENTS : Deflection = L/360 Cmx = 1.000 Cmy = 1.000 Ey = 0.000 in. Ex = 0.000 in. =_______ ___ GROSS / NET SECTION PROPERTIES BASED ON 1998 AISI SPECIFICATIONS (BOXED Configuration) Area Gross = 1.888 iu^2 Area Net = 1.169 io^2 Ix Gross = 11.474 io^4 8x Gross = 2.869 iu9 Rx Gross = 2.927 in. x-bar = 1.625 in. Ix Net = 11.443 inA4 Sx Net = 2.861 iu^8 Rx Net = 3.128 in. Iy Gross = 2.475 inA4 Sy Gross = 1.523 inA3 Ry Gross = 1.360 in. y-bar = 4.000 in. Iy Net = 2.060 inA4 Sy Net = 1.208 inA3 Ry Net = 1.327 in. m = 0.000 in. J = 6.802062 io^& mm = 0.000 in. Cw = 2.9258 inA6 8w = - 0.7713 io^5 Bf = 1.3681 iu^5 Bl = 1.0353 inA5 j = 0.8297 in. ro = 3.228 in. Beta = 1.000 __ Ixx/Iyy Required = 0.000/ 0.000 iuq ALLOWABLE LOADS Lateral Loads (X/Y) = 0.00/ 0.00 psf Overall Nominal Failure Load = 27,862 lbs. Overall AIlowuble Axial Load = 15,479 lbs. Omega = 1.80 Nominal Y-Axis Moment Capacity = 40,476 in-lbs Allowable Y-Axis Moment Capacity = 29,626 in-lbs Omega = 1.67 Nominal Cap. (Web in Tension) = 40,476 in-lbs Allowable Cap. (Web in Tension) = 29,626 in-lbs Iyy Effective at Comp. Yield = 1.058 inA4 Min. Syy Effective at Comp. Yield = 0.990 inA3 Min. Nominal X-Axis Moment Capacity = 138,891 in-lbs Allowable X-Axis Moment Capacity = 83,168 in-lbo Omega = 1.67 Ixx Effective at Comp. Yield = 11.290 inA4 Sxx Effective at Comp. Yield = 2.796 inA3 Allow. Load Considering Lat. Load (Comp/Tension) = 15,470/ 35,007 lbs. Lat. Load Moments (X/Y) = 0/ 0 in-lbs Allmmblm Shear Load on Unreinforced Web = 8,104 lbs. > Actual Shear Load = 0 lbs. Allowable End One-Flange Loading Reaction = 1,263 lbs. > Actual End Reaction = 0 lbs. Izu for Deflection Determination = 11.474 inA4 - at Current Stress Level in Section of 11,560 psi Iyy for Deflection Determination = 1.058 inA4 - at Maximum Stress Level in Section of 50,000 psi ___-------------------- 9DOB86, Version 5.00 - RMJ & ASSOCIATES Printed On 06-01-2010 at 10:08:08 Page 1 of 1 RMJ #41 103 Linden Avenue Washington Square South San Francisco, CA 94080 9585 S.W. Washington Square (650) 871-2282 Job No.: 10164 Date: 6/1/10 Fax: 871-2459 By: mas Pa 9e: Lateral Loads on Storefront Lateral loads on storefront shall be based on maximum of: 2006 IBC Section 1607.13, 5 psf In some cases, a conservative load, based on a higher seimic force may be used. Max storefront ht = 13.00 ft co=5 psf x .5 x 13 ft 32.5 plf OR (0= 18.4 plf (See following sheet for determination of seismic loads) Use w= 32.5 plf for loads perpendicular to storefront. Use co= 18.4 plf for loads parallel to storefront. RMJ 103 Linden Avenue Washington Square South San Francisco, CA 94080 9585 S.W. Washington Square (650) 871-2282 Job No.: 10164 Date: 6/1/10 Fax: 871-2459 By: mas Page: G\ Lateral Force on Elements (ASCE Code Section 9.6.1.3) ap- - 1.0 Rp= 2.5 Ip= 1.0 Sds= 0.5 Sms= 0.8 Ss = 0.6 Fa= 1.354 z= 1.0 h= 2.0 Fp= (0.4*ap*Sds)/(Rp*Ip)*(1+2*(z/h))*Wp= 0.161 W Fp shall not be less than 0.7CalpWp and need not be greater than 4CalpWp Fp= 0.3*Sds*I p*Wp= 0.15084 WP Fp= 1.6*Sds*Ip*Wp= 0.80446 W Fp= 0.161 Wp/1.4 Wp= 160 plf Fp= 18.4 plf IM 0 ;:t/ P4A Vi.04,44 I 1,g (1, 7,'`,,^■;V :.--- (4, RMJ Structural Engineers Robinson 103 Linden Avenue Job No. i t 1 4-( Date /0 1 (4.-,41 Meier . So.San Francisco,CA 94080 Juilly & Associates 65o871•2282 FAX 650 871.2459 Signed by fru/ it 1 (:: Sheet No. It of / 4) r s.1 e..). fLI iir-cv, ,,,,,!..- I f-,,,- 'lc es c L'7. 7 H e-.- •-;'--t 0 K. ,:_ 7: v';.,4-k-,'7- 1 ir-,7 F .:- L t) s (,4 V. ie "7;44. ot ', )) 2 5441 D6- Alf,i.a,el to r 3 0 i G pre:4- RMJ 103 Linden Avenue Washington Square South San Francisco, CA 94080 9585 S.W. Washington Square (650) 871-2282 Job No.: 10164 Date: 6/1/10 Fax: 871-2459 By: mas Page: 01, Full Height Built-up Box Columns (resists loads parallel to storefront) Maximum Height= 13 ft 156 in (strong axis) Height of Box Beam= 12 ft 144 in (weak axis) V Pmax= 80 plf x 27.5 ft/2 Pmax= 1,100 lbs Storefront Length = 27.5 ft Number of Full Height Columns = 2 Vmax= 18.4 plf x 27.5 ft/2 = 252.8 lbs Mmax= 252.8 lbsx 12 ftx 1 ft/ 13 ft = 2,801 in-lbs Use 2 full ht. columns w/2-362S162-54 Studs &2-362T150-33 Tracks Only 2-362S162-54 Properties used in design of box column. See following sheet for PROP 86 print-out. PMax= 1,100 lbs <Pa= 7,979 lbs OK Mmax= 2,801 in-lb <Ma: 36,786 in-lb OK 1. ALL STOREFRONT SIGNS REQUIRE SEPARATE PERMITS AND APPROVALS THIS IS A COMMERCIAL TENANT BUILD OUT OF A NEWLY DEMISED SPACE. THE TENANT SCOPE OF WORK IS ALL NEW 2. NO EXTERIOR VENDING OR DISPLAY SHALL BE ALLOWED. AND INCLUDES R E C E I V E D 3. ALL EXTERIOR MECHANICAL UTILITY, AND COMMUNICATION EQUIPMENT SHALL BE SCREENED TO THE HEIGHT OF -FLOORING, PARTITIONS, CEILINGS, FINISHES AND FURNISHINGS. THE TALLEST UNIT BY PARAPET OR SCREEN WALL THAT MATCHES THE ARCHITECTURAL COLOR AND -INTERIOR STOREFRONT AND ENTRANCE It/a/111 , c ,,,f ARCHITECTURAL FINISH OF BUILDING. GROUND MOUNTED MECHANICAL, UTILITY, AND COMMUNICATION EQUIPMENT -ELECTRICAL EQUIPMENT, LIGHTING AND POWER SHALL BE SCREENED BY A SCREEN WALL THAT MATCHES THE ARCHITECTURAL COLOR AND ARCHITECTURAL FINISH -PLUMBING AS REQ'D FOR LOUNGE AREA SINK, TOILETROOMS AND MOP SINK AREA OF THE BUILDING, WHICH IS A MIN OF 1'-0" HIGHER THAN THE HIGHEST POINT OF TALLEST UNIT. -VERTICAL TRANSPORTATION (ESCALATOR AND ELEVATOR) US220 V I N GTO N SQUARE � r �ry�_ 4. ALL EQUIPMENT, UTILITIES, OR OTHER APPURTENANCES ATTACHED TO THE BUILDING SHALL BE AN INTEGRAL PART OF THE BUILDING DESIGN IN TERMS OF FORM,APPURTENANCES AND TEXTURE. 9585 S.W. WASHINGTON SQUARE :? :: �DIVISION PORTLAND, OR 97223 CITY NOTES 12B SCOPE OF WORK 9 US220 1. STOREFRONT SIGNAGE I WASHINGTON SQUARE ARCHITECTURAL R�nsED STRUCTURAL REVISED NGS 2. AUTOMATIC FIRE SPRINKLER SYSTEM / FIRE ALARM - COORDINATION WITH LANDLORD SYSTEM CODE INFORMATION / EDITION S.W. WASHINGTON SQUARE 3. VERTICAL TRANSPORTATION - ESCALATOR, ELEVATOR ST ET # SHEET O R�'TImI SHEEP I SHEET DESORPTION UITE H08 BUILDING CODE: 2007 OREGON STRUCTURAL SPECIALTY CODE W/ 2006 IBC PORTLAND, OR 97223 DEFERRED SUBMITTALS 12A MECHANICAL CODE: 2007 OREGON MECHANICAL SPECIALTY CODE W/ 2006 IMO �� ; RED PLUMBING CODE. 2008 OREGON PLUMBING SPECIALTY CODE W/ 2006 UPC A0.0 COVER SHEET S1.0 GENERAL NOTES ELECTRICAL CODE: 2008 OREGON ELECTRICAL SPECIALTY CODE W/ 2008 NEC & NFPA 70 FIRE CODE: 20056 PORTLAND FIRE CODE W/ 2007 OREGON FIRE CODE AO.1 GENERAL NOTES AND PROJECT INFORMATION S2.0 INTERIOR STOREFRONT SECTION & DETAILS ACCESSIBILITY CODE: 2006 INTERNATIONAL BUILDING CODE CH.11 �� � , _ x__ AO.2 RESPONSIBILITIES AND FINISH SCHEDULES AMENDMENT; CITY OF PORTLAND AMENDMENTS Park AO.3 DOOR SCHEDULE AND DETAILS = `� a A0.4 SITE PLAN AND EGRESS PLAN svv Gar BUILDING DATA: '� �# , A2.Oa CONSTRUCTION PLAN - FIRST LEVEL BUILDING CONSTRUCTION TYPE: II B FULLY SPRINKLERED ZONING: PRC A2.Ob DIMENSION PLAN - F1RST LEVEL OCCUPANCY USE: M - MERCANTILE A2.Oc CONSTRUCTION PLAN - MEZZANINE LEVEL QUANTITY OF EXITS REQUIRED: 51411 (SEE AO.4) PROVIDED: 5 rPark A2.Od DIMENSION PLAN - MEZZANINE LEVEL MECHANICAL / PLUMBING I ELECTRICAL SEISMIC ZONE: D 1-5 -it D , 5 d , ti ...0( cles ter; � � 7!':-� - SPRINKLER SYSTEM/ FIRE ALARM CONNECTION: YES- UNDER SEPARATE PERMIT. � f A2.1a BACK OF HOUSE ENLARGED PLAN SECOND LEVEL E0.1 LIGHTING NOTES AND LIGHTING FIXTURE SCHEDULE SIGNAGE: YES- UNDER SEPARATE PERMIT, ! ,�:f . � .la A2.1 b FITTING ROOMS ENLARGED PLAN EO.2 PANEL SCHEDULES SQUARE FOOTAGE: 19,503 OCCUPANCY LOAD: 598 1 � A2.2a FINISH PLAN - FIRST LEVEL los �� x E0.3 POWER RISER AND LOAD SUMMARIES ELEVATOR: YES- UNDER SEPARATE PERMIT. • r _ ",` ° � �`� A2.2b FINISH PLAN - MEZZANINE LEVEL EO.4 ELECTRICAL DETAILS w '� A2.3a FIXTURE PLAN - FIRST LEVEL E2.1 a ELECTRICAL UGHT1NG PLAN - FIRST LEVEL MEDA. C1 A2.3b FIXTURE PLAN - MEZZANINE LEVEL E2.1 b ELECTRICAL LIGHTING PLAN - MEZZANINE LEVEL CODE SYNOPSIS 3 �, rrr Grove A3.Oa REFLECTED CEIUNG PLAN FIRST LEVEL E2.20 ELECTRICAL MONOPOINT LIGHTING PLAN - FIRST LEVEL OCCUPANT LOAD SQUARE WISER OF EXtiS � ' O' V r� : FIRST EEVEL AREA FACTOR FOOTAGE REQUIRED La : ' A3.Ob REFLECTED CEIUNG PLAN - MEZZANINE LEVEL E2.2b ELECTRICAL MONOPOINT LIGHTING PLAN - MEZZANINE LEVEL , t� r A4.0 BUILDING SECTIONS E2.3a ELECTRICAL COVE LIGHTING PLAN - FIRST LEVEL RETAIL 30 9,443 315 2 217 rk - A4.1 a INTERIOR ELEVATIONS - FIRST LEVEL E2.3b ELECTRICAL COVE LIGHTING PLAN - MEZZANINE LEVEL Heliport A4.1 b INTERIOR ELEVATIONS - FIRST LEVEL E3.1 a ELECTRICAL POWER PLAN i FIRST LEVEL O(;C(� p 9QlIARE pF EXITS r A4.1 c INTERIOR ELLIIATIONS - MEZZANINE LEVEL E3.1 b ELECTRICAL POWER PLAN MEZZANINE LEVEL MEZZANINE LEVEL AREA FACTOR FOOTAGE OCCUPANTS REQURED 4.- de A4.1 d INTERIOR ELEVATIONS - MEZZANINE LEVEL E3.2a AUDIO PLAN/SECURITY PLAN - FIRST LEVEL RETAIL 30 7700 257 2 A5.0 STOREFRONT ELEVATION / PLAN E3.2b AUDIO PLAN/SECURITY PLAN - MEZZANINE LEVEL OCCtA3ANT LOAD SQUAW TAKER OF DOTS .� °, A5.1 STOREFRONT SECTIONS E3.4 GENERAL NOTES AND CODED NOTES SECOND LEVEL AREA FACTOR FOOTAGE OOCUPANTS REQU�iED or rt n� A5.2 STOREFRONT & SIGNAGE DETAILS E4.1 ELECTRICAL DETAILS 1 858 II is,il STOCKROOM 300 7 � r A6.0 PARTITION DETAILS E4.2 ELECTRICAL DETAILS Dennis Heath, Architect OFFICES 100 269 3 A6.1 a CEILING DETAILS E4.3 ELECTRICAL DETAILS 2 4 0 II a r i n e r Square Lao p s A6.1 b CEILING DETAILS E4.4 LIGHTING CONTROL DETAILS STAFF AREA 15 233 16 Alameda, CA 94501 r 9 ��� 4�1��� � ������������� E4.5 LIGHTING CONTROL DETAILS '141./Lillairiut Si '74_.._ � �� __-- __-- - - ---- ---� _ A6.2 FLOOR AND BASE DETAILS TOTAL 2,360 26 j 1 A6.3 RESTROOM DETAILS AND ACCESSIBILITY COMPLIANCE E5.4 ELECTRICAL SPECIFICATIONS 598 5 H&M US220 WASHINGTON SQUARE TOTAL COMBINED 19,503 9585 S.W. WASHINGTON SQUARE N A6.5 MISCELLANEOUS DETAILS E5.1 ELECTRICAL SPECIFICATIONS .r11.113 a a d e r i t t e n o t e r i a l o e a r i n herein can e s t i t o t e e r i i e g I PP 9 9 SUITE H08 A7.1 FIXTURES AT SALES AREA E5.2 ELECTRICAL SPECIFICATIONS and unpublished nark of the Architect and net not be duplicated, PORTLAND, OR 97223 A8.0 MILLWORK DETAILS - ELEVATIONS AND SECTIONS M2.1 a MECHANICAL PLAN - FIRST LEVEL SQUARE FOOTAGE BREAKDOWN 2 used o r d i s c l o s Tel i r i t h o o t e r i t t e n consent o f t hie. e Architect A9.Oa ESCALATOR PLANS AND DETAILS M2.1 b MECHANICAL PLAN - MEZZANINE LEVEL D H ARCHITECTS-2 0 10 A9.Ob ESCALATOR SECTIONS AND DETAILS M2.1 c PARTIAL MECHANICAL PLAN LANDLORD: MECHANICAL ENt Q A Q C A9.1 ESCALATOR PLANS, SECTIONS AND DETAILS M2.1 d MECHANICAL NOTES THE MACERICH COMPANY HBK CONSULTANTS, LTD. 401 WILSHIRE BLVD.,SUTTE 700 171 CHARRING CROSS DRNE S. SUITE 1 B N o . Date I s s u e A9.2a STAIR DETAILS (SALES) M2.2 MECHANICAL CALCULATIONS do SCHEDULES SANTA MONICA, CA 90401 WESTERI�LLE OHIO 43081 VICINITY PLAN] 11 A9.2b STAIR DETAILS (BACK OF HOUSE) M2.3 MECHANICAL DETAILS TEL: 310.394.6000 TEL• 614.882.1199 FAX: 614.882.1857 05/28/10 100% SET CONTACT: WILLIAM BEST 05/28/10 VT PACKAGE SP,01 SPECIFICATIONS M3,1 a PLUMBING PLAN -- FIRST LEVEL WASHINGTON SQUARE EMAIL: WBESTAHBKCONSULTANTS.COM SP.02 SPECIFICATIONS M3.1 b PLUMBING PLAN MEZZANINE LEVEL 9585 S.W. WASHINGTON SgUARE ROAD 07/02/10 100 COMPLETE SET PORTLAND, OR 97223 07/28/10 LANDLORD SET SP.03 SPECIFICATIONS M3.1 c PARTIAL PLUMBING PLAN, NOTES, AND ISOMETRICS TEL 503.352.8884 FAX: 503.620.5612 08/13/10 PERMIT/BID SET M3.2 PLUMBING DETAILS AND SCHEDULES CONTACT: TOMOMI MARIAN - TENANT COORDINATOR FJLEOaTR[CAI. ENgI►E� M4.1 a SPRINKLER HEAD PLAN - FIRST LEVEL EMAIL: TOMOMI.MARZANOMACERICH.COM HBK CONSULTANTS, LTD. M4.1 b SPRINKLER HEAD PLAN - MEZZANINE LEVEL 171 CHARRING CROSS DRIVE S. SUITE 1 B E" UR M5.1 MECHANICAL SPECIFICATIONS WESTERVILLE, OHIO 43081 4� 0 TEL: 614.882.1199 FAX: 614.882,1857 M5.2 MECHANICAL SPECIFICATIONS H&M HENNES & MAURIIZ LP CONTACT: RALPH KEPPLER 8570 WEST SUNSET BLVD. SUITE 6.2 EMAIL• RKEPPLEROHBKCONSULTANTS.COM WEST HOLLYWOOD, CA 90069 � TEL 310.734,2553 FAX; 201.246.4825 a CONTACT: BIBI SUKEY - CONSTR. PROJECT MANAGER XPIINtirr EMAIL: BIBLSUKEYOHM.COM BULpNG QEFAR'11rIENT: CITY OF TIGARD DRAWING INDEX ;' 5 ARCHIIEICT: 13125 SW HALL BLVD O : MBH ARCHITECTS TIGARD, OR 97223 I 2470 MARINER SQUARE LOOP TEL: 503.718.2436 FAX: 503.624.3681 0 °' ._ S EXAMINER 5 Ez ALAMEDA, CA 94501 CONTACT: DAN NELSON - PLAN I s i 4 1. NOTHING IS PERMITTED TO BE ATTACHED TO, SUSPENDED FROM, OR PENETRATES THE ROOF DECK ABOVE. 10. ENGINEERED DRAWINGS OF NEW FIRE ALARM DEVICES, LOAD CALCULATION AND TIE-IN TO MALL FIRE ALARM TEL: 510.814.3441 FAX: 510.865.1611 EMAIL• DANN0TIGARD-OR.GOV �� w TENANTS ARE REQUIRED TO FRAME, BRACE AND/ OR SUSPEND, AS NEEDED, TO/ FROM THE TOP CHORD OF SYSTEM IS REQUIRED AT COST. CONTACT DAVE COLEITO WITH SIMPLEX/ GRINNELL AT 602.243.6700. CONTACT: MICHAEL THOMAS / ANA VINO os I z� JOIST OR STRUCTURAL STEEL WHICH EXIST ABOVE YOUR RESPECTIVE TENANT SPACE. UNISTRUCT SY;iTEM NEED 11. GENERAL CONTRACTOR SHALL BE HEW RESPONSIBLE TO PROTECT ALL MALL FLOOR TILES IN FRONT OF THEIR EMAIL: MICHAELTQMBHARCH.COM / 1- �..,.. i -- TO BE USED LEASED SPACE ANANBMBHARCH COM _ 2. FULL PERMITS ARE REQUIRED FOR SIGNAGE. SUBMIT THEM UNDER SEPARATE COYER. 12. ACCESS PANELS MUST BE PROVIDED FOR ALL LANDLORD SERVICEABLE EQUIPMENT WHICH IS ABOVE ANY HARD TUALATIN VALLEY FIRE AND RESCUE fw. ; O ,, E -, �� 3. NO SAW GUTTING WITHOUT PRIOR APPROVAL OF MALL STAFF AND TENANT COORDINATION. SAW CUT ON GRADE CEILING AREAS. SUPPLY VENTS AND RETURN VENTS ARE ALLOWED ASIA MEANS OF ACCESS. UNITS ABOVE HARD 1850 SW 170TH t � � 44122 ONLY. ALL OTHER AREAS TO BE CORE DRILLED. MAXIMUM CORE DRILL HOLE SIZE IS 8 INCHES. CEILINGS MUST HAVE A WORK PLATFORM CONSTRUCTED ABOVE THE CEIUNG FOR UNIT SERVICING. IF A WORK ENGP1EER: ALHA, OR 97007 Project N o ALL STOREFRONT CONSTRUCTION SHALL BE SEFL-SUPPORTING FROM THE FLOOR AND INDEPENDENT OF THE PLATFORM IS NOT CONSTRUCTED, A LETTER MUST BE SUBMITTED UPON JOB CLOSEOUT STATING THAT THE RMJ & ASSOCIATES TEL 503.649,8577 u � Y . 4. CONTACT. ROLAND PROFFlT BUILDING FASCIA AND BULKHEAD STRUCTURE. CEILING IS RATED TO WITHSTAND ALL ASSOCIATED WEIGHT WHILE SERVICING THE EQUIPMENT ABOVE. 103 LINDEN AVENUE S c a I e AS NOTED _: ; 0 _ 5. ALL SECURITY DEVISED SHOULD BE FULLY CONCEALED FROM PUBLIC VIEW. THEY MUST RECESS INTO THE SLAB SOUTH SAN FRANCISCO, CA 94080 r n x e � "3 NO MORE THAN 3'4 IF THEY REQUIRE DEEPER THAN " THEN TENANT MUST OBTAIN MALL STRUCTURAL TEL: 650.871.2282 FAX: 650.871.2459 sx„sc,4 J.5 FAY ROAD ,.s .j ENGINEER APPROVAL AT TENANTS EXPENSE. CONTACT: JAYSON HAINES D r a x n B y: DM/AN 6. RESTROOM FLOORS MUST HAVE A WATERPROOF MEMBRANE INSTALLED NO LESS THAN 6 INCHES UP EACH WALL. EMAIL JHAINESORMJS C _ T 7. TENANT SHALL BE HELD RESPONSIBLE TO MAINTAIN THE INTEGRITY OF THE EMS NETWORK CABLE WITHIN THEIR SPACE DURING ALL PHASES OF CONSTRUCT1ON, GENERAL CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY OF Firs `''; ;,1er A Are:'���,`.'f.`1 I. El - , i „,,i1,. . ,lprc31 "d...:.:.::::: :... wR 1,H&M US220 WASHINGTON SQUARE AY DAMAGE OR DISRUPT1ON TO THE EMS NETWORK " ' C:\Temp\AcPublish�332\US'120JO.dwg SUITE H08 8. GENERAL CONTRACTOR SHALL EXERCISE EXTREME CARE DURING ALL PHASES OF CONSTRUCTION SO AS NOT TO =y r� t rWlHil�►fA DAMAGE OR DISRUPT UTLTTIES WHICH MIGHT PASS THROUGH THIS SPACE TO SERVICE OTHER TENANTS. GENERAL Q'�' ` 'p a t�•d P�ri t . �t111���r Drawing No. - 0 CONTRACTOR BEAR SOLE EXPENSE FOR ANY SUCH DAMAGE OR DISRUPTIONS. 'i N Truss Engineering �"?., , ,,. -jtU ,. ! 9. GENERAL CONTRACTOR SHALL BE HELD RESPONSIBLE TO ENSURE THAT ALL EQUIPMENT AND DEVISES MEET ALL Shap Drawings _._.... L, ---- t,mn_- . COVER SHEET .. LANDLORD REQUIREMENTS AND CURRENT MAIL STANDARDS. Othec -�-Y-� Q 1 T O :7- _.__, KEY PLAN 10 LANDLORD NOTES 4 PROJECT DIRECTORY 1 -0.: AOIO EXISTING FULLY NEW/UPGRADE DETAILS ACOUS. ACOUSTICAL F.O,M• FACE OF MASONRY OPNG, OPENING _ ._ t 1. AT LEAST ONE ACCESSIBLE ENTRANCE. COMPLYING TO COMPLYING IN DRAWING VENDOR CATEGORY COMPANY CONK? ADJ. ADJUSTABLE F.R. FITTING ROOM OPP. OPPOSITE NOTE THIS SHOULD BE THE PRIMARY ENTRANCE. A.F.F. ABOVE FINISHED FLOOR F.R.T. FIRE RETARDANT TREATED P. LAM. PLASTIC LAMINATE 1. ALL WORK IS TO CONFORM TO ALL APPLICABLE CODES AND REGULATIONS. ADDITIONAL UPGRADE MAY BE REQ'0. IF IT'S NOT. ❑ III A2.0 ALUM. ALUMINUM GA. GAUGE PLYWD. PLYWOOD 2, THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS AND APPROVALS PRIOR TO THE GENERAL CONTRACTOR PR. PAIR ALT. ALTERNATE G.C. 2. AN ACCESSIBLE ROUTE TO THE AREA OF REMODEL I ❑ A0.1 LIGHTING SPECIALTY STORE LIGHTING CONTACT: MICHAEL RICIGLIANO APPROX, APPROXIMATE GYP. GYPSUM P.T. PRESSURE TREATED COMMENCEMENT OF WORK. 3. ONLY ONE TOILET ROOM UNLESS OTHERWISE REQUIRED ❑ I 4/A6.3 35 INDUSTRIAL PARK ROAD 110 TEL: 860.767.0110 x221 FAX: 860.767,5008 BD. BOARD H•C• HOLLOW CORE PTD. PAINTED 3. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED INSPECTIONS AND CERTIFICATES. CENTERBROOK, CT 06409 HDCP. HANDICAP R.C.P. REFLECTED CEILING PLAN 4. VISUAL/AURAL ALARM ❑ EMAIL MWROSSUGHTING.COt BLDG, BUILDING 4. THE CONTRACTOR WILL BECOME FAMILIAR WITH EXISTING CONDITIONS AND SHALL VERIFY EXISTING FIELD 719r4A4 BLKG. BLOCKING HDW. HARDWARE REC. RECESSED 5. ACCESSIBLE DRINKING FOUNTAIN ❑ 3/A6.3 SQU ' P -∎ 3 DER ELECTRIC CONTACT: JOHN KELLEY CONDITIONS IN THE FIELD PRIOR TO COMMENCEMENT OF WORK. AND SHALL REPORT ANY DISCREPANCIES x6 FAX: 859.372.1255 B O BOTTOM OF HT HEIGHT REV. REVISION BETWEEN THE DRAWINGS AND FIELD CONDITIONS TO THE ARCHITECT. LIGHTING CONTROL �L• B.O.H. BACK OF HOUSE HORIZ. HORIZONTAL REQ D. REQUIRED 6. ADA-COMPUANT SIGNAGE ❑ III 9/A6.3 3570 CONCORD ROAD 0' •..' ., CHNEIDER-ELECTRIC.COM CLG. CEILING HR. HOUR RM. ROOM 5. FOR GENERAL CONDITIONS REFER TO AIA DOCUMENT A201 1997. 7. OTHERS: DESCRIBE MEANS OF COMPLIANCE: I.E. N/A YOR, '• .+ CL CLOSET IN. INCH R•O. ROUGH OPENING 6. ALL WORK IS TO BE WARRANTED FOR A PERIOD OF NO LESS THAN ONE YEAR. --------- --------- -------- ---- ..... . ..----- . ......: S.C. SOLID CORE PARKING SPACES, ELEVATORS, STAIRS, ETC. LIGHT STAT CONTACT: BESTSY RENOUF CLR. CLEAR ISUL INSULATION 7. THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF LOCAL AUTHORITIES AND NOTE 22W WEST HILL ROAD, CELL 800,292.2444 x222 CO C. CONCRETE JAN. JANITOR SSIM. SCHEDULE BUILDING MANAGEMENT. BARKHAMSTED, CT 06063 EMAIL B.RENOUFOUGHTSTAT.COM 8. ALL ELECTRICIANS AND PLUMBERS INVOLVED IN THE WORK ARE TO BE LICENSED. CONT. CONTINUOUS JST, JOIST SPEC. SPECIFICATION 1. THIS PROJECT WILL COMPLY WITH ALL AMERICAN WITH DISABIUTIES ACT REGULATIONS AND ALL LOCAL STONE TILE LEA TILE NORTH AMERICA C. CTR, CENTER JT. JOINT SQ. FT. SQUARE FEET 9. ELECTRICAL WORK SHALL BE FILED SEPARATELY BY THE ELECTRICAL SUBCONTRACTOR. ACCESSIBILITY AND ENERGY CODE REQUIREMENTS. CONTACT. ELISA BELLUCI 800 CLANTON RD SUITE N TEL 201.865.2121 FAX: 201.865.2534 DBL.. DOUBLE LAM. LAMINATE • • STAINLESS STEEL 10. DEMOLITION IS TO BE PERFORMED IN AN ORDERLY MANNER, PER THE RESTRICTIONS, REGULATIONS AND HOURS US220 2. PROVIDE INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) AT 60" ABOVE FINISH FLOOR ON STRIKE SIDE WALL CHARLOTTE, NC 28217 DIA. DIAMETER LAV. LAVATORY SSD. SEE STRUCTURAL SET BY THE BUILDING MANAGEMENT. DEBRIS IS TO BE DISCARDED OFF SITE IN A PROPER MANNER AND NOT AT ACCESSIBLE FITTING ROOM DOOR(S). SYMBOL SHAPE AND CONTRASTING COLORS SHALL CONFORM WITH DIM. DIMENSION LIN. LINEAR DRAWINGS ALLOWED TO ACCUMULATE IN THE WORK AREA. WASHINGTON SQUARE ALL LOCAL, STATE AND FEDERAL ACCESSIBILITY AND ENERGY CODE REQUIREMENTS. ILLUMINATED SIGNS ID SIGN SYSTEMS CONTACT: RITA READ DN. DOWN LL LANDLORD STD, STANDARD 11, DIMENSIONS GIVEN ARE TO FINISH SURFACES UNLESS OTHERWISE NOTED. 467 EAST RIDGE ROAD EMAIL RRODOIDSIGNSY,STEMS.COM DWG. DRAWING LT, LIGHT STL STEEL 9585 S.W. WASHINGTON SQUARE 3. PROVIDE ACCESSIBILITY SIGNAGE ON RESTROOM DOORS TO CONFORM WITH ALL LOCAL, STATE AND FEDERAL ROCHESTER, NY 14621 CONTACT: PAUL DUDLEY (E) EXISTING MAX. MAXIMUM STRL STRUCTURAL 12. THE CONTRACTOR SHALL LAYOUT HIS OR HER OWN WORK, AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR ACCESSIBILITY AND ENERGY CODE REQUIREMENTS. EA. EACH MECH. MECHANICAL SUSP SUSPENDED OTHER TRADES (PLUMBING, ELECTRICAL, ETC) SUITE H08 4. PROVIDE CLOTHING HOOK AT 44" ABOVE FINISH FLOOR IN ACCESSIBLE FITTING ROOM(S). EMAIL PDUDLEYOIDSIGNSYSTEMS.COM EL ELEVATION MFR. MANUFACTURER TEMP. TEMPERED 13. ALL CONTRACTORS MUST BE APPROVED BY BUILDING MANAGEMENT AND ALL CONTRACTORS TO COMPLY WITH PORTLAND, OR 97223 TEL: FAX. 585,2fi6.5798 ELEC. ELECTRICAL MIN. MINIMUM THK. THICK 5. ALL CUSTOMER SERVICE CHECKSTANDS SHALL CONFORM TO ALL LOCAL, STATE AND FEDERAL ACCESSIBILITY _...- MANAGEMENT CONSTRUCTION STANDARDS AND BUILDING RULES. CONTRACTORS TO USE UNION LABOR WHERE AND ENERGY CODE REQUIREMENTS, SEE CASHWRAP SHEET FOR CLEAR DIMENSIONS AND COUNTER HEIGHTS. SAFE WILSON SAFE COMPANY CONTACT: ROBERT KASSOFF EQ. EQUAL MISC. MISCELLANEOUS T.O.C, TOP OF CONCRETE REQUIRED. CLASS: RED 3031 ISLAND AVE BOX-5310 TEL 215,495.0790 / 516.739.2557 EQUIP. EQUIPMENT MTD. MOUNTED TYP. TYPICAL. - FAX 51 fi.739.5455 EXTERIOR MTL. METAL- U.O.N. UNLESS OTHERWISE DOORS PHILADELPHIA, PA 1914 F.D• FLOAT DIMENSION (N) NEW NOTED NOT -OOVERI D BY WILDING t:OQ� EAMIL RKASSOFFOWILSONS_AFE.C_O M F.F. FINISH FLOOR N N/A NOT APPLICABLE VERT, VERTICAL A. LATCHES AND LOCKSETS: PROVIDE LEVER TYPE, PUSH- PULL OR PANIC TYPE HARDWARE 34 INCHES MANUFACTURED CASEWORK & MILLWORK B&N INDUSTRIES CONTACT, LYNN PETERS FIN. FINISH N.I.C. NOT IN CONTRACT V.I.F. VERIFY IN FIELD 1. PROPOSED WORK TO COMPLY WITH APPLICABLE REQUIREMENTS OF LOCAL BUILDING CODES FOR HANDICAPPED TO 48 INCHES ABOVE FLOOR. FLR. FLOOR NO. or # NUMBER W.C. WATER CLOSET FLOOR FIXTURES TEL. 650.533.4127 DIRECT. 650.393.2317 FLASH. FLASHING N.T.S• NOT TO SCALE WD, WOOD ACCESS, B. ADJUSTABLE CLOSURE PROVIDED WITH MAXIMUM PRESSURE FOR OPENING DOORS AS FOLLOWS: 1409 CHAPIN AVENUE 2ND FLOOR FAX: 650393.3112 INTERIOR DOORS - 5 POUNDS PRESSURE BURLINGAME, CA 94010 EMAIL LPETERSOBNIND.COM FLUOR. FLUORESCENT O,C• ON CENTER W WITH THOT 2. HANDICAPPED ACCESS. S TO COMPLY WITH THE APPLICABLE REQUIREMENTS OF LOCAL. BUILDING CODES FOR EXTERIOR DOORS - 8.5 POUNDS PRESSURE F.O.F. FACE OF FINISH O.F.I. OWNER FURNISHED ITEM / FIRE DOORS - 15 POUNDS PRESSURE JP METAL AMERICA CONTACT: JOHN MATEO 0. FIXTURES TO BE PROVIDED WITH REQUIRED CLEAR FLOOR SPACE AS PER THE REQUIREMENT OF LOCAL ADJUST CLOSURES AFTER INSTALLATION AND TEST DOOR COMPLIANCE. STORE FIXTURES (CASHPOINTS, TEL 514.648.4276 CELL 514.915.1266 ABBREVIATIONS 6 BUILDING CODES. NEW FIXTURE TO BE SUBJECT TO THE REQUIREMENTS OF LOCAL BUILDING CODES C. FLOOR LEVEL AT DOORS FTTTINGROOMS, PERIMETER) CONCERNING DIMENSIONS AND ADAPTABILITY, AS SHOWN IN ATTACHED DETAILS, � D SHOULD NOT REQUIRE THRESHOLDS: THE FLOOR OR LANDING SHALL NOT BE 7335 HENRI-BOURASSA E. II�!.� DETAIL REFERENCE PT-1 WALL FINISH 3, CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AN TIGHT GRASPING PINCHING OR TWISTING OF THE WRIST AS PER LOCAL BUILDING CODES MORE THAN 1/2 INCH LOWER THAN THE THRESHOLD OF H1E 3T5 MONTREAL, QUEBEC AX.X DRAWING NUMBER ' ' , r THE DOOR WAY. CHANGE IN LEVEL BETWEEN 1 4 INCH 111 ........... ._._... .,,,,_..r " 4, ACCESSIBLE ROUTES TO BE PROVIDED, PROVIDING A MINIMUM OF 32 INCHES OF WIDTH AT DOORWAYS, AS PER sr / ARRAY NEW YORK CONTACT: ROBERT THIRY X X CEILING HEIGHT 1 j AND 1/2 INCH SHALL BE BEVELED WITH A SLOPE NO I-'�❑ 1/2 MAX. LOCAL BUILDING CODES. -�, GREATER THAN 1:2. (SEE ADJACENT). ARDWARE TEL 212,750.3367 FAX 212.750.6068 X-X CEILING TYPE 5, EMERGENCY WARNING SYSTEMS SHALL INCLUDE BOTH AUDIBLE AND VISUAL ALARMS AS PER LOCAL BUILDING 611 1 { NT) THRESHOLDS 1/4 MAX.( A GRID BUBBLE � - ,{ E I"Ft 5 EAST 57TH STREET, 3RD FLOOR EMAIL RTHIRYOARRAYMARKLTING.COM CODE RESPECTIVELY. 10 LEVEL FLOOR OR LANDING: THERE SHALL BE A LEVEL AND CLEAR AREA ON EACH SIDE OF AN EXIT NEW YORK, NY 10022 REVISION TAG 6 PROPOSED STORAGE FACIUTIES SUCH AS CABINETS, SHELVES, CLOSETS, AND DRAWERS SHALL COMPLY WITH ~' - DOOR. THE LEVEL AREA SHALL BE AS SHOWN IN FIGURE 6A. THE SPACE BETWEEN TWO CONSECUTIVE AMERICAN AIDES VENTILATION CORP. CONTACT: JOHN HARRELL le, DOOR TAG APPLICABLE REQUIREMENTS OF LOCAL BUILDING CODES. ALAIVEDA, CA DOOR OPENING (VESTIBULE) SHALL PROVIDE 48 INCHES OF CLEAR SPACE FROM ANY DOOR OPENING RAC DIFFUSERS 4537 NORTHGATE COURT TEL: 941.351.3441 FAX: 941.351,3442 7. FOR NOTES ON ACCESSIBILITY CONFORMANCE. REFER TO 10/A0.1 INTO SUCH SPACE (SEE BELOW), SARASOTA, FL 34234-2124 EMAIL JOHAOALDES-US.COM XX ELEVATION, SECTION REF. X KEYNOTE ' D. DOOR WIDTH & HEIGHT: 3 FEET WIDE AND 6 FEET 8 INCHES HIGH. CLEAR WIDTH: 32 INCHES MINIMUM WITH I' DOOR OPEN 90 DEC. MEASURED FROM NE FACE OF THE DOOR TO THE OPPOSITE STOP. BARRI 11 r-, :- PRINT INTERNATIONAL CONTACT: ' '. ' ' s �A) X� DRAWING NUMBER TENANT PLAN E. THE BOTTOM 10 INCHES OF ALL o NS PLACE FR3 ••DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH • : 516.223,7177 / 516.528.6656 CT-1 FLOOR TAG DATUM POINT 1. GENERAL ALL WORK TO BE DONE IN ACCORDANCE WITH THE LOCAL BUILDING CODES AND REGULATIONS OF ALL UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOT- REST , • • 867.0722 OTHER AGENCIES HAVING JURISDICTION. WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. EMAIL RMAR'11N I • '- - ,- - » WB-1 2. STRUCTURAL PULL SIDE PULL SIDE X - 36* MIN IF ROWNG GRILLE METRO DOOR, COOKSON, OVERHEAD BASE TAG WALL TAG a. CONTRACTORS TO PROVIDE ADEQUATE TEMPORARY BRACING AND SHORING WHEREVER ANY STRUCTURAL WORK o ac Y = 60 OR WAYNE DALTON $gi < 24 MIN. X = 42' MIN IF STOREFRONT CANOPY SUMBRELLA 16809 US HWY 19 SUITE B SYMBOLS LEGEND 5 b. X ALL DEMOLITION OPERATION, REPAIR OPERATION, AND ALTERATION OPERATIONS TO BE DONE IN ACCORDANCE CLEARWATER, FL 33764 _ = 54" CELL: 727.524.1120 FAX: 888.722.2137 ARCHDE�T'URAL � �. �� WITH THE LOCAL BUILDING CODES. / D / REVIEWED BY: INSPECTION REQUIRED BY: 3. MEANS OF EGRESS: ALL EXISTING MEANS OF EGRESS FOR TENANTS OF THE BUILDING TO BE MAINTAINED CLEAR ' MOIMMEMMEMEM SECURITY AND LOSS H&M HENNES & MAURITZ CONTACT: GLENN STRABLE STRUCTURAL/STRICT MANAGER MEP ELEMENT AND FREE OF ALL OBSTRUCTIONS, SUCH AS BUILDING MATERIALS, TOOLS, ETC. Sw $w PREVENTION 8570 W. SUNSET BLVD CELL: 415.216.6668. FAX: 201.246.4798. 4. FIRE SAFETY: z g < . 8- g...7-, > » WEST I O LYWOOD,CA 9 STOREFRONT WINDOW SYSTEM ARCHITECT ARCHITECT NO ,m ,L U m ,��,, 10 MIN. BOTTOM � ---- ------- --..... ..._.... ------- .: .. ---... ... _-.---- -.. . -.----. --.-.... -.---.--- ---.-.- -...-. .....--- FOR ALL BUILDING MATERIALS STORED AT CONSTRUCTION AREA, AND/OR BY GENERAL CONTRACTOR. Dil T R I L O G Y L O G I C S ALARM LOCK „------. ... ... ...... ........ .. . .. _ - ._- _____- _-- ---- -------- - -_--.: ...... _ _. . . . .... .._._: .--_- , , , , RAIL OR PROVIDE C O N T A C T: D A V E B R A C E Y a. ALL MATERIALS T O BE STORED IN AN ORDERLY FASHION. D e n n i s Heath, A r c h i t e c t $41, ? I PUSH SIDE r W?' I PUSH SIDE I KICK PLATE - MODEL TRILOGY T2 TEL 631.793.4243 FAX: 631.789.3383 ELEVATOR ARCHITECT ARCHITECT NO b. ALL FLAMMABLE MATERIALS TO BE KEPT AWAY FROM HEAT. 2 410 Mariner Square l o 0 54" MIN NO SUBSTITUTIONS C. ALL FLAMMABLE MATERIALS TO BE USED AND STORED IN AN ADEQUATELY VENTILATED SPACE. p 3 4 5 B A Y VIEW AVENUE RE-INFORCED CONCRETE S A l a m e d a, CA 94501 LATCH APPROACH HINGE APPROACH AJrIfTMLE, NY 11701 LOAD BEARING CMU WALL STRUCTURAL ENGINEER ARCHITECT STRUCTURAL ENGINEER d. ALL ELECTRICAL POWER TO BE SHUTOFF WHERE THERE AREA EXPOSED CONDUITS. e. ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA TO BE SHUT OFF AFTER WORKING HOURS. BURGLAR ALARM / SYNERGY SECURITY SYSTEMS / CONTACTS: MICHAEL MADDEN SHORING, LAGGING, NEEDLING, SHORING CONTRACTOR ARCHITECT NO f. CONTRACTOR, AT ALL TIMES, TO MAKE SURE THERE ARE NO LEAKS OF NATURAL GAS IN BUILDING, OR ANY ELECTRONIC ARTICLE SURVEILLANCE NEDAP TEL 800686 8330 CELL 203 520 2218 ' PULL SIDE TEMPORARY BRACING FLAMMABLE GAS USED IN CONSTRUCTION. 48 MIN. 200 MAIN STREET SUITE IA -.-: EMAIL MMADDENO►SYNERGYSECURITY.COM CLEAR SPACE IS MONROE, CT 06468 STRUCTURAL STEEL 5. DUST CONTROL NECESSARY TO CONTACTS: MATT ERNEST STRUCTURAL ENGINEER ARCHITECT STRUCTURAL ENGINEER Drawings and written material appearing herein caastituke original V 18' MIN. a. DEBRIS, DIRT AND DUST TO BE KEPT TO A MINIMUM, AND BE CONFINED TO THE IMMEDIATE CONSTRUCTION ■ TEL 800.686.8330 and in published work of the Architect and may not be duplicated, ■ ALLOW BACKING AREA p 1 P 1B AND TURNING CELL 203.520.1046 H&M SIGNAGE ARCHITECT OWNER NO used or disclosed without wriltea consent of the Architect MIN. SPACE FORA EMAIL MATTOSYNERGYSECURITY,COM b. CONTRACTOR TO ISOLATE CONSTRUCTION AREA OCCUPIED BUILDING AREAS BY MEANS OF TEMPORARY D H ARCHITECTS- 2010 --, , WHEELCHAIR TO PARTIONS OR HEAVY WEIGHT DROP CLOTHS. A PROVIDE THIS ADDITIONAL = 1, 32" CLEAR THE IN- AUDIO/VISUAL EQUIPMENT BW SOLUTIONS CONTACTS: BEN NOURY GLASS GUARDRAIL AND STAIR ARCHITECT ARCHITECT NO c. DEBRIS, DIRT AND DUST TO BE CLEANED UP AND CLEARED FROM BUILDING PERIODICALLY TO AVOID ANY ,�' '( SWINGING DOOR. 2722 LOKER AVE WEST, SUITE D TEL 760.431.2833 FAX: 619.241.6743 Q A Q C SPACE IF DOOR IS CLEAR CARLSBAD, CA 92010 EXCESSIVE ACCUMULATION. • v EMAIL: BNOURYOBWSOLCOM � EQUIPPED WITH BOTH A 6. NOISE AFTER HOURS: VERIFY WITH LANDLORD ON-SITE REPRESENTATIVE L A T C H AND A CLOSER. �- BOH MILLWORK ARCHITECT ARCHITECT NO N o . D o t e I s s u e I PUSH SID VESTIBULE DMX MUSIC CONTACTS: LINDA TOLMAN a. CONSTRUCTION OPERATIONS WILL BE AUTHORIZED BY LANDLORD. �I --- --------- 05/28/10 100% SET 12" MIN. 300 W. MAIN STREET ... ... ..... b. CONTRACTOR TO OBTAIN THE WRITTEN CONSENT OF ALL PARTIES AFFECTED BY HIS WORKING DURING OTHER TEL. 508.439.5013 FAX: 508.393.5137 INTERIOR CUSTOM COLOR 05/28/10 VT PACKAGE FRONT APPROACH FIGURE 7A NORTHBOROUGH, MA 01532 EMAIL UNDA.TOLMANIDMX.COM PAINT ARCHITECT OWNER NO THAN REGULAR HOURS. 07/02/10 100% COMPLETE SET 8" r- ECI 04 ' • I#NS CONTACTS: BART RENO AS BUILT DRAWINGS GENERAL CONTRACTOR OWNER NO 2 0 PROTRUDING OBJECTS ' MIN•' / 3100 NW BOLA RA o " TEL 5. .•:• LL 561.703.6873 GENERAL NOTES 07/28/10 LANDLORD SET / SUITE 309 .. ... .... ,... . . .... ... ... .,.. ..... ... ..: . ........ .... . .. 08/13/10 / / DOCA RATON, FL - STAINLESS STEEL ARCHITECT ARCHITECT NO PERMIT BID SET A. PROJECTIONS FROM WALLS WITH ' \ / EMAIL reno0369AY '09. LEADING EDGE BETWEEN 27" AND SUB--CONTRACTOR COMPANY CONT�T 80' ABOVE FLOOR MAY PROJECT 4' / ELECTRICAL PANELS ELECTRICAL ENGINEER ELECTRICAL ENGINEER NO MAXIMUM. LEADING EDGE AT OR \ BELOW 27 MAY PROJECT ANY FIRE SPRINKLERS WYATT FIRE PROTECTION, INC GENE WYATT z AMOUNT. FREE STANDING I :::/ TRANSFORMERS ELECTRICAL ENGINEER ELECTRICAL ENGINEER NO TEL 503,684,2928 PROJECTIONS WITH LEADING EDGE ;.■ / BETWEEN 27» AND 80 a N ABOVE , \ / ELECTRICAL PROVIDED LIGHTS ELECTRICAL ENGINEER ELECTRICAL ENGINEER NO ARE ALARM SIEMENS BUILDING TECHNOLOGIES, INC JEFF NEELY FLOOR MAY PROJECT 12" MAX. z / MD LAMPS TEL 503.234.9995 PROJECTIONS MAY NOT REDUCE MANEUVERING SPACE, OR CLEAR 'v, / DEVICES ELECTRICAL ENGINEER ELECTRICAL ENGINEER NO WIDTH OF AN ACCESSIBLE ROUTE. ' / ,11' MIN. 6" MIN. ELECTRICIAN FRAHLER ELECTRIC COMPANY ADAM ETHERINGTON B. HEAD ROOM: 80 MINIMUM. 25■ MAX, SAFETY DISCONNECT SWITCHES ELECTRICAL ENGINEER ELECTRICAL ENGINEER NO (FOR FINAL TEL: 503.639.4627 CONNECTIONS) 0 KNEE AND TOE CLEARANCE MOTOR STARTERS ELECTRICAL ENGINEER ELECTRICAL ENGINEER NO ROOFING CONTRACTOR BOB CARLSON ROOFING, INC BOB CARLSON _----- _. ...:. ... . ........ ......... ........ ...... ........ ..... _ A. ELECTRICAL RECEPTACLES (15, 20 AND 30 AM TEL 503.640.3623 PS} SHALL BE AT LEAST 15 INCHES ABOVE THE FLOOR. DOOR BUZZER PUSHBUTTON NO B. SWITCHES AND CONTROLS FOR LIGHTS, APPLIANCES, COOLING, HEATING AND VENTILATING EQUIPMENT SYSTEM ELECTRICAL ENGINEER ELECTRICAL ENGINEER SHALL BE NOT LESS THAN 3 FEET NOR MORE THAN 4 FEET ABOVE THE FLOOR. DUMPSTER SERVICE IEM DIANA C. ARE ALARM INITIATING DEVICES SHALL BE 48 INCHES ABOVE THE FLOOR, GROUND OR SIDEWALK. ARE ALARM SHOP DRAWINGS ELECTRICAL ENGINEER ELECTRICAL ENGINEER NO (INTERNATIONAL ENVIRONMENTAL MANAGEMENT) TEL 800.290.8051 x354 0 TACTILE EXIT SIGNS HVAC UNITS MECHANICAL ENGINEER MECHANICAL ENGINEER PLAN EXPEDITOR WESTERN DESIGN GROUP DAVID HARDISTER x E 4612 NE MINNEHAHA ST. EACH GRADE LEVEL EXTERIOR EXIT DOOR SHALL BE IDENTIFIED BY A TACTILE EXIT EXHAUST FANS MECHANICAL ENGINEER MECHANICAL ENGINEER NO VANCOUVER, WA 98661 Project No. 44122 CORRESPONDING WITH THE WORD "EXIT. EACH EXIT DOOR THAT LEADS DIRECTLY TO A TYPE II BRAILLE 4 GRADE-LEVEL EXTERIOR EXIT BY MEANS OF A STAIRWAY OR RAMP SHALL BE _ AIR DEVICES MECHANICAL ENGINEER MECHANICAL ENGINEER NO ENERGY MANAGEMENT ENVIRONMENTAL CONTROLS, ANC DALE NOLAN BY A TACTILE EXIT SIGN WITH THE FOLLOWING WORDS � 7606 SW BRIDGEPORT RO S c a I e AS NOTED IDENTIFIED AS APPROPRWTE. ❑ Ex"�J 1, "EXIT STAIRS DOWN sg TUALATIN, OR 97224 DAMPERS NO ENGINEER MECHANICAL ENGINEER D r a w n B y: DM/AN 2. "EXIT RAMP DOWN" 1 "EXIT STAR UP" Exicr N 0 Vj 7 4. "EXIT RAMP UP" ° °,�e g TEMPERATURE CONTROLS (Li NO REQUIRED CONTROLS) MECHANICAL ENGINEER MECHANICAL ENGINEER 0 EAEACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS OF AN EXIT ENCLOSURE OR AN EXIT PASSAGEWAY SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS "EXIT ROUTE." PLUMBING FIXTURES AND TRIM MECHANICAL ENGINEER MECHANICAL ENGINEER NO R:\HM\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220_A01.0 EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR OR HALLWAY THAT IS REQUIRED N TO HAVE A VISUAL EXIT SIGN, SHALL BY IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS "EXIT ROUTE." NO FOR THE FULL UST OF THE LANDLORD (NOT REQUIRED) SUB-CONTRACTORS REFER TO WASHINGTON SQ MALL TENANT 0 ,fl EACH EXIT DOOR THROUGH A HORIZONTAL EXIT SHALL BE IDENTIFIED BY A SIGN WITH THE WORDS `TO EXIT.' SPRINKLER SHOP DRAWINGS MECHANICAL ENGINEER MECHANICAL ENGINEER DESIGN CRITERIA. Drawing N o. 60 INCHES FINISH E; MOUNTING HEIGHT SHALL BE ABOVE THE FLOOR TO THE CENTER LINE OF THE SIGN. MOUNTING GENERAL NOTES & " LOCATION SHALL BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3 INCHES OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF THE DOOR. PROJECT INFORMATION N d WHERE APPLICABLE: FIRE/LIFE SAFETY ENG. SUBMITTED TO OWNER FOR RECORD FILE. ACCESSIBILITY CONFORMANCE AND 10 10 TACTILE EXIT SIGNAGE 10 VENDOR LIST 8 SHOP DRAWINGS / PRODUCT SUBMITTAL 4 LL. REQUIRED SUB-CONTRACTORS 1 A 0•1 i i.... URNISHEL INSTALLED ABBREVIATIONS: FURNISHEDINSTALLED ABBREVIATIONS: TAG MANUFACTURER DP110N / � BY BY G.C. GENERAL CONTRACTOR BY BY G.C. : GENERAL CONTRACTOR TENANT TENANT T.V. TENANT VENDOR TENANT TENANT T.V. : TENANT VENDOR LL : LANDLORD LL, : LANDLORD �_1 PAINT BENJAMIN _ CEILINGS, LIGHT GAP CEILING, KID'S & BABY SALES CEIUNGS AND PORTALS TO KIDS AREA g H d g H ENJAMIN MOORE OC 65 CHANTILLY LACE I GLOSS: FLAT U.O.N. SEE RCP FOR LOCATION. PRE-CONSTRUCTION : .:. . AREA(CONTINUATION) : 8A1.�9 (v 1'IOlrq PT-2 PAINT BENJAMIN MOORE OC-65 'CHANTILLY LACE" I GLOSS; EGGSHELL U.O.N. SALES AREA WALLS, TYP,; ALL WALLS IN BACK OF HOUSE, TYP. _ • • • • • • SEE FINISH PLAN FOR LOCATION. TEMPORARY UTILITIES & FACILITIES = • ■ 1 AVAILABLE, FEE TO GC. COORDINATE W/ LL FITTING ROOM DOORS / FRAMES / HARDWARE • • 111 DOOR PROVIDED BY VENDOR PT-3 PAINT BENJAMIN MOORE 2134-30 "IRON MOUNTAIN" I GLOSS: FLAT FLOATING CEILING IN KID'S / BABY SALES AREA BARRICADE AT STOREFRONT • ■: REMOVAL BY G.C. SEE NOTE 111 FITTING ROOM ACCESSORIES • ■ SEE NOTE 5; BLOCKING BY GC SEE RCP FOR LOCATION. - BARRICADE GRAPHIC # ■ COORDINATE WITH PRINT INTERNATIONAL FITTING ROOM CORNER GUARDS • ■ REFER TO A2.1 b PT-4 _ ■ KIDS / BABY AREA SALES AREA WALLS AS INDICATED, TYP. PAINT BENJAMIN MOORE - E 2028 10 "IGUANA GREEN I GLOSS. EGGSHELL SEE FINISH PLAN FOR LOCATION. SAWCUTTING, CORING, CHANNELING OF (E) CONCRETE • ;; ■ X-RAY AS REQUIRED AREA RUGS _ # ■, MEN S / kI{�S-SALES-TEMPORARY POWER POWER & LIGHTING • • SEE NOTE 11 LCD / VIDEO SCREENS • ■ SEE NOTE 11 PT-5 PAINT BENJAMIN MOORE 2132-10 "BLACK" GLOSS: FLAT SALES AREA AND PORTAL CEILING. DUMPSTER • ■ MUSIC SYSTEM SPEAKERS •• <' SEE RCP FOR LOCATION. ■ " MENS SALES AREA WALLS, CASHWRAP WALL AND PORTALS. ASBESTOS ABATEMENT / CLEAN AIR CERTIFICATE ' • ■ SECURITY CAMERAS • ■ US220 PT-6 PAINT BENJAMIN MOORE 2132-10 "BLACK. GLOSS: EGGSHELL SEE FINISH PLAN FOR LOCATION. CCTV VIEW MONITOR • ■ :: :: C WASHINGTON SQUARE CTV BRACING & ANCHORING r ■ ■ KIDS.:::.:::..BA►811.::.SALES.::.AREA::.:FLAATING:::.CFI .........................._..............-. PT 7 PAINT BENJAMIN MOORS HC 167 GREY f GLOSS. FIAT / LING.............................................::::::::::::::::::::::::::::::::::::::::::::.:..:::.,..:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: • SEE RCP PLAN FOR LOCATION. CONCRETE FLOOR SLAB • ■ EXISTING BURGLAR ALARM • ■ S.W. WASHINGTON SQUARE r . EXISTING REAR SERVICE DOOR HARDWARE BY G.C. SUITE H08 _ __ _ _ �... .. : MEZZANINE SLAB • ■: • •< • ■ KIDS BABY:.:SAL.ES:.AREA::;ACCENT,W PT 8 PAINT BENJAMIN-MOQRE HC 1 fi7 -GREY -# fiLOSS.-�E€3GSHELL / � TYP• ........ ...... ........ ....::... .,...,. ....,,.., ,,;,,,,, ......... .,,,,.... .,...;, SEE FINISH PLAN FOR LOCATION. •.> ESCALTOR, ELEVATOR, U REAR SERVICE UGHTING : PORTLAND, OR 97223 .... ._... DUCTS AND STAIRS :: OPENING IN SLAB (INCLUDING PITS) PT-9 PAINT BENJAMIN MOORE 2134-40 "WHALE GREY" GLOSS: EGGSHELL BOH ACCENT COLOR. ELEVATOR • ■ GC TO COORDINATE INSTALLATION. SEE NOTE 111 DELIVERY BUZZER SYSTEM •' ■ AT REAR SERVICE CLASS: RED SEE FINISH PLAN FOR LOCATION. ESCALATOR • ■ GC TO COORDINATE INSTALLATION. SEE NOTE 113 PLASTIC CORNER GUARDS ' • ■ i FITTING ROOM AS INDICATED ON PLANS DISPLAY WINDOW PT-10 PAINT BENJAMIN MOORE 1-04 "DECORATORS WHITE" HIGH GLOSS STAIR FRAMING • ■ EXISTING. GC TO PROVIDE FINISHES. BASK OF HOUSE : SEE FINISH PLAN FOR LOCATIONS. TRILOGY CODED LOCKSETS STAIR FINISHES / ■ • - osomoomummommommomml - ■` � SEE NOTE 12 & #5 . PAINT BENJAMIN MOORE HC-105-28 ROCKPORT GREY-SABLE 'ASPESIEW EGGSHELL WOMEN'S SALES AREK"SEE F1NISHf PLAI<i I'OR:LOCATIONS. ::::. FLOOR SLAB PREPARATION • ■: INCLUDES LEVELING / PATCHING AS REVD COAT RACK • ■ IN BACK OF HOUSE, COORD. LOCATION W/H&M. RAM OMENS DEMISING WALL (CMU/METAL STUDS) • ■ EXISTING. SEE NOTE BULLETIN BOARDS • ■ IN BACK OF HOUSE, COORD. LOCATION W/H&M. DEMISING WALL GYP. BD. • ■!. SEE NOTE #4. TENANT SIDE ONLY AS REQ'D STANDARDS / SHELVES / BRACKETS •' ■ SEE NOTE f7 CPT-1 AREA RUG TBD KESHAN, PERSIAN WOOL 9386, 9404 MEN'S SALES AREA, SEE FINISH PLAN FOR LOCATION ARE SAFNG / ARE PROOFING • ,' ■ AS REQUIRED BOH FIXTURES • ■ SEE NOTE #7 CPT-2 STOREFRONT LOCKERS • ■ AREA RUG TBD ESTHER, GREEN 38-3008 KID'S / SALES AREA, SEE FINISH PLAN FOR LOCATION REFRIGERATOR / MICROWAVE / SINK • ■< IN LOUNGE ROOM • _ LEA CERAMICHE OR 24" X 24" X 3/8"-92331 "DARK GREY" W/ 1/8" GROUT JOINTS NEUTRAL PIERS • ■ EXISTING; NEW S.S. FINISH RESTROOM ACCESSORIES • ■ SEE NOTE #3 & #5 y,A,' t ` ' ! '. CST-1 STONE TILE GRANTT1 F1ANDRE 24" X 12" X 3/8"-92332 "DARK GREY" FOR STAIR TILE SALES AREA FLOOR - ,i ,'� f I REVEAL • ■' AT NEUTRAL PIERS ONLY FLOOR SAFE • • ■ AT ADMIN. ROOM. COLOD. W/ VENDOR • 4ill rs r r r ! j �,,.� 8 X 8 UNGLAZED PORCELAN DALTILE, GRIGIO GRANITE CD40 - y • �_1 MENS & WOMEN'S RESTROOM FLOOR & WALLS STOREFRONT & GLAZING • ■ MILLWORK, COUNTERS, CABINETS, PULLS & SHELVING • ■ AT LOUNGE, DECO, ADMIN ROOM ► ,H + ' CERAMIC TILE DALTILE (1-800-365-8453) (ABRASIVE AT FLOOR ONLY). BULLNOSE AT ALL EXPOSED EDGES _ ■ JANITOR'S CLOSET'S FLOOR :: : :: - . T.:: Y :- . .... -:.:: ,: ....:._... ...._. . ::: .: :..... -- . T..:: ...::. . , . cen STAINLESS STEEL CORNER GUARDS ON PLANS WITH 1 8 GROUT JOINTS. 8WX6H COVED BASE EXTERIOR 5'TOREFRONT-SYSTEM-. de GIAZtNG _ _ � - TO MATCH E -STOREFRONT-AT-EXTERIOR- • :. ■ BACK OF HOUSE AS INDICATED 0 � LLT-1 LANDLORD TILE MATCH LANDLORD TILE TBD G.C. TO COORDINATE SPECIFICATION, PATTERN AND PURCHASE WITH LANDLORD. GLAZING, GLAZING CLIPS & CHANNEL • ■ WAINSCOT • ■ (12:,,, Al A�El;y� • SEE FINISH PLAN FOR LOCATION. - VINYL TILE AND BASE ■ „ AT-EXTERIOR GLAZING t1N-INTERIOR SIDE- • ■ C� MDF MDF BOARD BID 3/4 MDF BOARD AT PLATFORM DISPLAY AREA PLATFORM & OP WIN STRUCTURAL STEEL • ■' AS NEEDED MUSIC CONTROL SYSTEM • ■ G.C. TO PROVIDE CONDUITS OXi. TO BE PAINTED PT-2 EN WINDOW PLATFORM LEASE LINE TO CLOSURE LINE FLOORING • : TOILET ROOM FLOORING & WAINSCOT & • 12" " ■ BOH FLOORS: DECO LOUNGE AR HARDWARE ROOM ■ REFER TO FINISH PLAN CERAMIC T11.E • ■" LOUNGE...BACKSPLASH VCT-1 - EA, , SECURITY, ADMIN ROOM, MANAGER'S/SECURITY CT 1 12 X 12 51 � 807 "SHADOW BLUE :: __ __ __ _ __ __ _ _ VINYL COMPOSITE TILE ARMSTRONG WALK-4 ---MAT ....._. ,. .... ,i....... ,,,, ..,#.., .......... .--.--REFER TQ fiNtSH:.�f�1aMF:FOR::,.SPEC..:. ........ ..:...... MOP SINK •' ■ ROOM, ELECTRICAL ROOM, LAN ROOM & PROCESSING AREA C■.Ii10 STOREFRONT SIGNAGE s # ■ < COORDINATE WITH SIGN VENDOR DRINKING FOUNTAI�1:. .....:. BLADE SIGN # ■ WATER FILTRATION S�FSTEM •..• :.� GC =T4:.,PRtMDE-::PLUMBING :.. ........- PRELUDE EXPOSED 15/16 T-GRID SYSTEM, DIRECT HUNG, WHITE _ ACT-1 ACOUSTICAL CEILING TILE ARMSTRONG BAKED ENAMEL FINISH; EDGE TRIM WITH VERTICAL LEG BACK OF HOUSE CEILING. REFER TO DETAIL A6.1 b. STAINLESS STEEL STOREFRONT PANELS • ■ PLAN TUBE HOLDER •' ■% SEE PLAN FOR LOCATION CONCEALED. DUNE 1772 2' X 2' PANELS STONE...TtLE....WAtt;,FINtS#•1 s GYP-1 'TYPE 3' GYP. BD. C - ' Dll GYP. BD. CEILING BID CEILING PAINTED WHITE PT 1 ... SEE fl00R SCHEDULE !"NCNT�:110�1., BABY SALES AREA CEILINGS ENTI�If DOORS & HARDWARE # ■ ROLLING GRILLE • ■ GRILLE SUPPORT-COLRD. W/ VENDOR _ GYP-2 GYP. BD. CEILING BID "TYPE 4" GYP. BD. CEILING PAINTED BLACK PT-5 MEN'S, WOMEN'S & DMDED SALES AREA CEILINGS ROLLING GRILLE ACCESS PANEL • ■ AT GYP. BD. CEILING. SEE RCP. SPRINKLER MAIN TO PREMISES • ■:. , , NEDAP SYSTEM - Heath, Architect • SPRINKLER BRANCHES DROPS AND HEADS • r ■ AT ENTRY COORD. WI VENDOR ■ SEE NOTE 6 GYP 3 GYP. BD. CEtLTNG BID "TYPE 5 GYP. BD. CEtLTNG PAtNTEf GREY f�T 7 KIDS/BABIES SALES AREA=FLOATTNG CEILING =- _ FIRE ALARM S Y S T E M • ■ SEE NOTE 110 2410 Mariner S q u a r e Loop ALL O a Y i _SMOKE DETECTORS • ■ A l a m e d a, C A 94501 '-1 WAINSCOT MARLITE P-100 PEBBLE FINISH WAINSCOT AT NON-SALES CORRDOR AREAS. REFER TO FINISH PLAN, INSTALL UP TO FIRE EXTINGUISHERS • ■ COORDINA LOCATION W/FIRE MARSHALL & H&M 4-0 AF.F. - REP.. aA1.66 Af■A ' SS-1 STAINLESS STEEL TBD 20 GAUGE PANELS STOREFRONT FASCIA & PILASTERS STONE TILE • ■ SALES, STAIR AND F.R. FOOT Ct�NIgTIPBJCflON r e herein constitute Droning:a aad Witco material fR_.. 1,A ..:SAC`(R.ES...tNt„Yh:... ALE ...AhLD....IxR,.......:..: r SEI f tEVEI fiVG Cf3NCREfE fLf30�R # ■ __ FITTING-ROOMS & STAIRS. : g e is appearing here' askitut original WT-1 3" X 6' - 0790 ARCTIC WHITE, RITTENHOUSE SQUARE WITH - aar unpublished sock of the Architect and nay not be duplicated, CERAMIC TILE ARMSTRONG 1/16" GROUT JOINTS LOUNGE AREA BACKSPLASH GROUTS •' ■ ANAL CLEAN UP • ■ A T CONSTRUCTION COMPLETION u s e d or d i s c l o s e d r i t h o u t w r i t t e n c o n s e n t of t h e A r c h i t e c t INTEGRATE VINYLY WALL BOH BASE: DECO, LOUNGE & ROOM, WOOD BASE • ■ CERTIFICATE OF OCCUPANCY • ■ 0 H ARCHITECTS- 2 0 10 VB-1 VINYL BASE ARMSTRONG '� BASE , SECURITY, ADMIN & MEETING ROOM, 92 CADET BLUE ELECTRICAL & LAN ROOM PROCESSING AR EA & JANITOR'S CLOSET PERMIT, FEES & INSURANCE • QA QC PAINTED AT BASE TO FOLOW WALL COLOR EXCEPT AT GREEN ACOUSTICAL & THERMAL INSULATION (AS REQUIRED) 1 •' ? 111' -1 MDF BASE TBD WALLS. VERIFY W/ H&M PM PRIOR T O APPLAY S A L E S AREA & FITTING ROOM BASE M E T A L STRAPPING, BLOCKING & LEDGERS „ •' 1 1 it 8T N o . D o t e I s s u e GROWS/swims GYP. BD. PARTITIONS (WITHIN LEASED SPACE) • ■ STUDS, FRT PLYWOOD, & GYP. BD. AS SHOWN 05/28/10 100% SET G-1 GROUT RAL DESIGN SYSTEM REFERENCE - 00300 OR NCS S 8000-N FOR USE WITH CT-1 WALL FINISHES • ■' INCLUDING PAINT, WALL COVERING, ETC, STRUCTURAL WORK-REFER TO STRUCTURAL DRAWINGS 05/28/10 VT PACKAGE G-2 GROUT MAPEI CORPORATION 02 - "PEWTER' FOR USE WITH CST-1 WALL STANDARDS, PANELS & HARDWARE • ■ SEE NOTE 5. RECESSED/SURFACE MOUNTED 07/02/10 100% COMPLETE SET POSTER GRAPHIC • ■ SEE FINISH PLAN FOR LOCATIONS 07/28/10 LANDLORD SET G-3 GROUT MAPEI CORPORATION 100- WHITE FOR USE WITH WT-1 PRE-FINISHED MDF • ■ DISPLAY PLATFORM 08/13/10 PERMIT/BID SET CLAN ACOUSTICAL TILE CEILING SYSTEM • ■ MECHANICAL WORK-REFER TO MECHANICAL DRAWINGS GL-2 STOREFRONT GLASS I BID 5/8" CLEAR TEMPERED GLASS AT STOREFRONT DISPLAY WINDOWS, (INTERIOR MALL LOCATION) GYP. BD. CEILING / SOFFITS / FRAMING • ■' ------ PANEL �CTEVt.�AL. FIBERGLASS ACCESS • • - HOLLOW METAL FRAMES & DOOR HARDWARE ■ GL�••4 STOREFRONT Gt.A'S''S Blfl 1 CLEAP TEMPERED GLASS EXTERIOR SFOREFRONFT CONDITION •' LIGHT FIXTURES & LAMPS •• ' ■ REFER TO E0.1 FOR RESPONSIBILITIES ELECTRICAL WORK-REFER TO ELECTRICAL DRAWINGS COVE LIGHTS • ■ CO-1 COUNTERTOP CORIAN 1/2" THICK - GLACIER WHITE COUNTERTOP IN LOUNGE ROOM CASHWRAP FIXTURE • ■ PLUMBING . CP-1 CABINET PULLS SUGATSUNE STAINLESS STEEL PULLS I SATIN FINISH CABINET PULLS FOR BOH CABINETS WARDROBE FIXTURE SYSTEM ;• ■ BLOCKING BY GC ILLUMINATED WALL PANEL SYSTEM • ■ PLUMBING WORK-REFER TO PLUMBING DRAWINGS EXTERIOR STOREFRONT GLAZING. APPLY TO Ti•fE IMTERIOR SIDE OF GLASS .:.:. _ :• BOXWALL FIXTURE • ■ R� TO '�ODNt64LL INSfRUL'110NS FOR OONiRAG1ORS" SG-1 SPECIAL GRAPHIC H&M PAINTED, VINYL, OR POSTER GRAPHIC PROVIDED BY OWNER, INSTALLED BY G.C. G.C. TO COORDINATED WITH H&M FREESTANDING FLOOR FIXTURES • ■ SEE NOTE 5; BLOCKING BY GC, TYP. PM AND ON SITE TEAM. FLOOR CABINET SYSTEM • ■ 949-58 WHITE COUNTERTOP FOR WORK SPACE, CABINETS & SHLEVES IN BOH OFFICES. FIXTURES AT COLUMN • PL-1 PLASTIC LAMINATE FORMICA I MATTE FINISH SEE ELEVATIONS ON A8.0 FOR MORE INFO. ■ BUILT IN FITTING ROOM I • ■ VW-1 WOOD VENEER OAK RIFT CUT WHITE OAK CABINETS, BASE CABINETS, BASE, FILLER & ACCESS PANELS IN LOUNGE - ROOM FLOOR UNITS AXED TO FLOOR :•; ■ EXECUTIVE STONE BASALT (LAVA STONE), HONED FINISH. BOOK SHELF • ■ ED SH ST � STONE TILE r r " r r STOREFRONT STT�IE TILE PANEL :.- .:: :.,.. ._ _ ::. ,., ...: . ...:_. 44122 A: 818-765-0900 12 X 24 X 1 2 & 16 X 24 X 1 2 CUT TO SIZE Project N o. / / SALES AREA MILLWORK • ■ BLOCKING BY GC MIRRORS • ■ 1 IN ATiiNG ROOM AND SALES AREA SEE NOTE #12 CARPET AND AREA RUG ■ IN FITTING ROOM AND SALES AREA AS INDICATED • Scale AS NOTED DrawnBy: DM/AN raven D M3R1 NOT POUte ON NB SCHEDULE 10 BE PROVIDED BY THE CEN3IAL CONTRACTOR E 7. ALL DIFFUSERS TO BE PAINTED WITH SEW-GLOSS FMNSH. ALL CEILING FIXTURES TO MATCH COM DOLOR. 8. INSTALLING BUT NOT LIMITED TO POS DATA, POWER AND PHONES 1. ALL PAINT TO BE BENJAMN MOORE - NO SUBSTTIUTIONS. 8. G.C. IS RESPONSIBLE FOR REPAIRING AM)/OR REPLACING MALI. TILE AS REQURED IN FRONT OF TIC LEASE UNE ALONG 1 ELECTRICAL. SERVICE AND CONNECTIONS BY G C R:\HM\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220�102.d 2 ALL WALLS NOT MARLED ON 11•E LAYOUT TO BE PAINTED PT-2. ENTIRE STOREFRONT G.C. TO COORDINATE PURCHASE ANA? DELIVER' OF TILE FROM LL 2. G.C. TO PURCHASE SCHEDULED FIXTURES FROM TENANT'S VENDOR. SEE VENDOR UST ON 8/A0.1 9. G.C. SHALL PUNCHDOWN TERMINATE EACH END OF CATS CABLES BOTH 66 BLOCKS IN L.L.'S CLOSET & TENANT'S ELEC. RM. N 3. BOH OPEN CEILING AREAS, EXPOSED COLUIuN'S, PIPES & EXPOSED ROOF DRAINS TO BE PAINTED, CONFIRM COLOR WITH H&M. 9. G.C. 1D PROVIDE CONTROL SAMPLES OF ALL FINISH MATERIALS FOR ARCHITECT'S REVIEW AND APPROVAL PRA TO INSTAU.ATDN. 3. SEE ACCESSORY SCHEDULE ON RESTROOM DETAILS 10. LL HAS INSTALLED A FIRE ALARM SYSTEM IN CONJUNCTION WITH ARE MARSHALL / BUILDING DEPT. REQUIREMENTS. 4. AT BATHROOMS AND JANITOR WERE WATER IS USED: TENANT MUST USE THIS SYSTEM & MUST USE LL CONTRACTOR FOR INSTALLATION & CONNECTIONS WITHIN SPACE. Drawing N o. ° -LL LATEX-RISER WATERPROOF TO BE USED BENEATH FLOOR FINISH (CT-1) AND TO EXTEND 10. G.C. TO PROVIDE AREAS (5 X5 MN.) OF ALL PAINT COLORS FOR CLIENT APPROVAL PRIOR TO COMMENCING 4. SEE DRAWINGS FOR ADDITIONAL REQUIREMENTS FOR EXISTING DEMISING PARTITION TO BE COMPLETED BY G.C.. INSTALLATION IS AT TENANT G.C. EXPENSE. COORDINATE WITH MALL OPERATION o " PAINTING, G.C. TO VERIFY IN FIELD BEFORE BID 11. LL TO INSTALL BARRICADE. G.C. TO COORDINATE WITH MALL OPERATIONS DIRECTOR FOR REMOVING CONSTRUCTION RESPONSIBILITY & MNNML•NuI 6 UP WALL 11. PRCMDE OWNER W/ 5 YARDS ATTIC STOCK OF EACH WALL FABRIC, CARPET, VCT, EACH STONE TYPE 5. INSTALLATION TO INCLUDE UNLOADING, UNPACKING, ASSEMBLY AS REQUIRED AND PLACEMENT AS DIRECTED BARRICADE WALL. ALL DAMAGE TO EXISTING STRUCTURE TO BE REPLACED BY L.L. CONTRACTOR AT G.C. EXPENSE. FINISH SCHEDULES -FLOOR � 12 G.C. 1�O PROVIDE 1 GAL IN OF EACH PAINT COLOR FOR OWI�R'S MAIMDVANCE. BY ON-SITE TEAM AND H&M PROJECT MANAGER. 12. GC TO PROVIDE AND INSTALL CORNER TO CORNER WALL MOUNTED MIRROR ON H/C FITTING ROOM 5. ALL EXPOSED PIPING AND CONIXAT TO BE PAINTED. G.C. TO MORO/ATE COLOR WITH H&M. 6. INCLUDING MODIFICATION OF ANY EXISTING HEAD LOCATIONS. 6� ALL EXPOSED DUCIWIQRK TO REMAIN UNPAINTED. 13. G.C. TO PROVIDE ALL REQURED PAINT TOUCH IRS AFTER FINAL MLLWORK AND FURNITURE DElNERY. 7, INSTALLATION TO INCLUDE RECEMNG, STORING AND UNPACKING, ASSEMBLE AND PLACE ALL BOH FURNITURE, 13. PROCUREMENT AND INSTALLATION BY TENANT. U. TO REIMBURSE TENANT PER LEASE AGREEMENT ONLY. >, 14. VINYL BASE COLOR TO MATCH WAIL PAINT COLOR. O AO.2 .2, FINISH SCHEDULE & NOTES 7 RESPONSIBILITY SCHEDULE _ 2.. _.._ . . 4" LOCAMON DOOR SIZE MATERIALS DETALS ARE HCAVR VARIES DOOR QTY. REMARKS / / TYPE WIDTH X NEWT X TIICKNESS DOOR HEAD JAMB WAD JAMB RATF1G SET 1,3 3/4" I if A N v STUDS PER WALL AS SCHEDULED WALL TYPE • 4110110 1 ROLLING GRILLE A 271-6" X 101-6" METAL METAL METAL 12/A5.2 - - 2/A5.2 - 1 \-- SE WALL TYPE MILLED HARDWOOD HEAD TRIM 2 DISPLAY WINDOW J 1"-10" X 31-6" X 1/2" GLASS - - - 118/A0.3 11A/A0.3 - 4 , I FOR # OF LAYERS 411110 14;IPI! :i/1141111:1!4/ 11/! !11/11! .d- ,r-O" A.F.F. K 3'-8' X 71-0" X 1 3/4" HM HM HM 9B/A0.3 9/A6.2 9A/A0.3 60 MIN. 5 --1--1----. \- EX)OR PLATE AT 51-6" A.F.F. ON DOOR, EXCEPT AT DOOR TO BOH. T.O. OPENING 1/2. /2" 411E110 3 (E) DOT/ SERVICE DOOR AND FRAME BY LL; G.C. TO MOUNT 3"X5" TENANT NAME CAULK JOINT (TYP.) C 31-0" X 71-0" X 1 3/4" HM HM HM 9B/A0.3 - 9A/A0.3 - 6 HARDWARE 5 FOR EMERGENCY EXIT DOOR 'TYPE K. a 4110111' 4 STAIR CID SEE FINISH PLAN FOR FINISH TRANSITION. wommon■woomoloolo■I FITTING ROOM - HALLWAY 4111 1 STORAGE ROOM F 1P-10" X 71-0" X 1 3/4" HM HM HM 8B/A0.3 - 8A/A0.3 3 14 2 C HM HM HM 12 \ 6 TOILET ROOM 31-0* X 71-0" X 1 3/4" 9B/A0.3 2B/A6.2 9A/A0.3 - 41110 1 JANITOR CLOSET C 3'-a" X 71-0" X 3/4" HM HM HM 913/N).3 2B/A6.2 9A/A0.3 - 13 US220 KNOCKDOWN PTD. )"."11.11.1 .1....- DOOR AS SCHEDULED MIL FRAME U.N.O. 8 1 SECURITY/ MEETING D 31-0" X 71-0" X 3/4" HM HM HM 9B/A0.3 3B/A6.2 9A/A0.3 - 8 GLASS WINDOW WITH PRIVACY SHADE WASHINGTON SQUARE 1 3/4" PM. H.M. DOOR > 9 1 ADMINISTRATION E 31-0" X 71-0" X 1 3/4" HM HM HM 9B/A0.3 3B/A6.2 9A/A0.3 - 9 VIEWER; ELECTRIC DOOR BOLT, SEE ELECTRICAL DRAWINGS. 9585 S.W. WASHINGTON SQUARE HEAD HEAD . H08 B B N 10 1 PROCESSING AREA C 3"--0" X r-on x 3/4" HM HM HM 9B/A0.3 3B/A6.2 9A/A0.3 - 10 PORTLAND, OR 9722'3 3/4" 4 1/2" WALL AS SCHEDULED CP 1 ELEC. ROOM C 31-0" X 71-0" X 1 3/4" HM HM HM 9B/A0.3 3B/A6.2 9A/A0.3 - 11 CLASS: RED t_ 21 ,Hi_ 1 LAN ROOM C 31-0* X 7ØN X 3/4" HM HM HM 9B/A0.3 3B/A6.2 9A/A0.3 11 401 FITTING ROOM I V I" ... \ it Cs1 ....... \..-- \ 1:0 9 RTTING ROOM G 21-2* X 51-3. X 3/4" WD WD WD 12B/A0.3 - 12A/A0.3 14 G.C.C TO FURNISH & INSTALL DOOR STOP. SEE A21 tit cir - omw■oomm■Noww■■0000mow . 12A/A0.3 G.C. TO FURNISH & INSTALL DOOR STOP. SE A21b -21- / • ts.. NI \___ <> C/3 1.4.1 41lEllo 16 2 1 HC FITTING ROOM MACHINE ROOM H C 31-0* X 51-3" X 1 3/4" 31-0" X 71-0" X 1 3/4" WD HM WD HM WD HM 12B/A0.3 9B/A0.3 - 1B/A6.2 -9A/A0.3 60 MIN. 14 11 G.C. TO INSTALL UNNERSAL ACCESSIBILITY SIGNAGE DOOR AS SCHEDULED 2X F.R.T. WOOD BLOCKING JAMB 1" X 6 3/4" MILLED (:"- :) JAMB HARDWOOD JAMB \ -04 A ...,. HEAD / JAMB AT FITTING ROOM DOOR I 1-1/21=T-0" .. I 12 HEAD / JAMB AT H.M. DOOR I T=T-01 ... I NOTES 1 h 111 1 r, , 4$ . t ' 1 1 k k 11 1111\ t! ,... 4. THE BOTTOM 10 INCHES OF ALL DOORS, EXCEPT AUTOMATIC AND SLIDING DOORS, SHALL HAVE A SMOOTH, UNINTERRUPTED ,'4,.1,7 qk, \,:a‘ 4 TH tori . voA BAUM GLASS DISMAY . VL-- 1. DIMENSIONS ON DOOR SCHEDULE SHOWS CLEAR OPENING REQUIRED. CONTRACTOR TO DETERMINE ROUGH OPENING SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS i ' < 5/8" GYP. BD. OVER AREA < WALL AS SCHEDULED DIMENSIONS. SEE SHOP DRAIWNG FROM MANUFACTURER CONDITION. - en .......3 METAL STUD FRAMING 1/2 TEMPERED GLASS 5/ 8* TH. WOOD FRAME 2. ALL LOCKS TO HAVE 'BEST' INTERCHANGEABLE CORES AND CYLINDERS WHEN APPLICABLE. 5. LANDLORD DOORS TO BE LEVER OR PUSH/PULL HARDWARE. • ON BO'TH SIDES AT PER GLASS 1 - 1/ • AND JAMB FLUSH TO 3. EXISTING DOORS TO REMAIN, NEW HARDWARE PER SCHEDULE, COORDINATE OUTSIDE FINISH AND SIGNAGE WITH ON-SITE 6. ALL DOORS TO BE OPERABLE WITH ONE OPERATION OF THE HAND, PER I.B.C. 1008.1.8.5. ALANIEDA, CA THIS LOCATION MANUFACTURER SPEC/ PTD. SOUD WOOD GYP BD TAPE AND LANDLORD TENANT COORDINATOR. vi°1).1,4 ROTS. PT-2 DOOR FRAME. MUD. SAND AND PAINT' 3 0 F °XI .rtiC...c:'''' _ -- PAINTED TO MATCH J-MOLD WI/ 1 SS SHOE WITH GROUT TO MATCH WALL. DOOR SCHEDULE _ DRY JOINT JOINT ADJACENTE FINISHES > UNE OF BASE ON SS SET NO. LOCATION CI1Y. DESCRE'TION MANWACTURES MODEL NO. FINISH NOTE I BELOW SHOE SIDE MDF OVER 1/2" STORAGE BALM 1 ENTRY 1 ROLLDOWN DOOR CONTROL COOKSON, OVERHEAD SEE DOOR SPEC PROVIDED BY CONCEALED BEHIND ACCESS DOOR. G.C. TO PROVIDE AND owwwoowwommoomowowool WOOD , !i PLYWOOD OVER 2 1/2' AND WAYNE DALTON MANUFACTURER WITH U-CHANGE INSTALL SIGNAGE ON STORE SIDE OF BOTTOM RAIL OF GRILLE • '1111'211 MIL STUDS LOCK CYUNER WITH THUMBTURN ON STATING "GRILLE TO REMAIN IN FULL OPEN POSITION BASE .m. 1,41,........„ BLIND DOOR (SALES STORE SIDE DURINGSTORE HOURS WHEN OCCUPIED BY THE GENERAL PUBLJC". *. HINGE,MS°EUNTEDOOD R SCHEDULE H -104111111 , SIDE) - REFER TO 2 2' la CYLINDER DEADBOLT BEST NDER DOOR SCHEDULE. LOCK ADAMS RITE 1850-A505 W/# 220 FACE PLATE THUMBTURN ON ■,11 1 r a. PAINTED TO MATCH 2EA - ' ; TOP, INTERMEDIATE, & BOTTOM: 1/2" CLEAR TEMPERED ADJACENTE FINISHES VISTAWALL 2EA DOOR HOLDERS FS452-5 .11 . STARPHIRE GLASS 0 WINDOW GLASS END CONDITION 2EA CONCEALED CLOSERS (OVERHEAD/DO :1 •' • . - = 1 G , KAWNEER OR i II !- '- - ,,,r,I.I DOOR, MOUNTED ON T.O. PLATFORM CONCEALED OVE*HEAD CLOSER W11. 10L---- ---mt!r• • OPEN HEAD 1EA SADDLE THRESHOLD (EXTERIOR) PEMKO OR EQ. A : 5' '; ' 'I OFFSET iirni THRE '1 ' ;- Dennis Heath, Architect B BLIND DOOR - REFER TO DOOR 1SET WEATHERSTRIPPING (EXTERIOR) •' •., - D INTO DOOR) AT DOOR BOTTOM AND MEETING STI 011 2470 Mariner Square Loop > FACE OF PLATFORM SALES DOOR DISPLAY SCHEDULE. PAINTED TO MATCH PE1v1K0 (SURFACE MID.) AT JAMBS AND HEAD. BELOW AREA ADJACENT FINISHES 4 I a 6 r• 'I N DORMA OGRO TG 9357 . • 4-0 LONG Alameda, CA 94501 SAES DOOR HANDLE 1 SIGN DECAL. SPECIALIZED BUILDERS HARDWARE 149: %HESE DOORS TO REMAIN... EI/W FINISH. . , SPECIALIZED BUILDERS HARDWARE 160. 44063X046i/H ACCESSIBLE DECAL; BLUE WITH CLEAR FIGURE SAMS DISPLAY , , 3 INC ' D HINGE SOSS 218 US26D ----ritR DOOR 1/2" CLEAR TEMPERED AUGN SOSS CONCEALED HINGES PM. SOLID WOOD JAMB 3 BLIND DOOR - .......... r,-; STARPHIRE GLASS DOOR, 1 MAGNETIC LATCH IVES 327 _ MOUNTED ON T.O. MOM 2 WALL MID. PIVOT HINGE GENEVA GENO 037; BRUSHED STAINLESS STEEL 4 DISPLAY ........_,, PLATFORM Ewsswso=IEIIIMIIIIIIIIIIIIIIIIIIIIMIIIIpll=IEISfiNIEIEI 1 GLASS DOOR LOCK BEST IC CORE BRUSHED STAINLESS STEEL 1 5 EXIT DOOR 3 HINGE (Eai _ _ BY LL Drawings and vritteo material appearing herein constitute original L and Inpublished vork DI the Architect and may not be duplicated, CORNER III II II Alla W/ PANIC E3AR ALARMED 1 CLOSER MDF OVER 1/2" 1 PANIC BAR ARROW AL SINGLETONE IF IT GOES TO BOH f DOUBLEIONE TO EXIT used or disclosed vithout vritten consent of the Architect BEAD ' G PLYWOOD OVER 2 1/2" 3 SILENCERS GLYNN-JOHNSON SR64 ODH ARCHITECTS- 2010 1111151 L STUDS ) AAII- WOOD BASE ow um M136ff.. 1 SET SEALS PEMKO (RATED) 305 CR AT FIRE RATED DOORS AT FIRE RATED DOORS < 1/2* CLEAR TEMPERED 1 5/ r TH. WOOD FRAME 1 SWEEP 1 THRESHOLD PEMKO PEMKO 305 CR ._ AL AT FIRE RATED DOORS QAQC Afillik GLAZING -I IN 5/8 PTD. GYP. BD AND JAAIB FLUSH TO GYP. BD. TAPE AND MUD. SAND 1 VIEWER 2 KICKPLATE BIVEURSN U700 B260 24 No . Dote Issue N..-..# GL-2 JAMB AND PAINT TO MATCH WALL. 6 STAIR 1 ANTI-VANDAL TRIM TRIMCO 1090 1091 3 HINGE STANLEY FBB179, FINISH US26D 05/28/10 100% SET MAGNETIC TOUCH LATCH 1 PANIC BAR ARROW 430 US26D BY GC 05/28/10 VT PACKAGE GLASS DOOR ENLARGE PLAN 0 DOOR GLASS END CONDMON 1 CLOSER LCN 4041 CUSH, ALUMINUM FINISH 1 SURFACE MOUNTED EXIT ALARM ALARM LOCK PG21 AT REAR MEZZANINE LEVEL STAIR DOOR ONLY 07/02/10 100% COMPLETE SET DOOR AT DISPLAY/ VOID AREA 1 1-1/211=1-0. - . 11 HEAD/JAMB AT CONCEALED DOOR -1/2"=1-0" .. .. 8 1 SILENCER GLYNN-JOHNSON DOOR STOP IVES SR64 FS13 US26D 07/28/10 08/13/10 LANDLORD SET PERMIT/BID SET jr VARIES 11/ PLACE STICKER ABOVE DOOR: "THIS DOOR TO REMAIN UNLOCKED ORIENTATION VARIES, SEE PLAN 7 MEETING ..3 1 1 HINGE STANLEY --r socxEr BEST DOOR STOP - "-"Ntr" FB8179 73KC-7-R-15D US26D 626 13 ill .1 - DURING BUSINESS HOURS" 2 KICK PLATE BURN 4 H ......usa2............................................,,.....„. .N.I 1 COP?, 4041H AL \ - \ _. 31-0" r SILENCERS GLYNN-JOHNSON SR64 r , / \ --.... ......-- .. . 1 •I / \ ,i, 31-0" .t.. 1 • 3TIACE - A I .. \ if' 2-0 il, VARIES ,, 8 SECURITY/ MEETING _ , 1 CODED LOCKSET TRILOGY DL2700IC-T2 US26D BY GC \ \ \ \ 1 DOOR STOP IVES FS13 US26D / PTD. HOLLOW ili VIEWER 2 KICK PLATE BURNS 24"Fl US32D L;1 / \ \ HOLLOW METAL DOOR . 1 CLOSER LCN 4041H Ai. - im / \ / / WHEN 3 SILENCERS GLYNN-JOHNSON SR64 12 v) uj 1.0 / - \ a c, METAL DOOR • / / i ..in SOLID •/RE / SPECIFIED GRILLE HOUSING .. (, \ ,,) I id. / a 4:::, GLASS OPENING a WOOD I rn 9 ADMINISTRATION 3 HINGE STANLEY FBB179 US26D LW < GRILLE GUIDE \ 1 DOOR 1 CODED LOCKSET TRILOGY DI-2700IC US26D BY GC , cy, , SEE HARDWARE _ \\ ____-).-• 7,,. SEE HARDWARE \ -I 2 KDDDICKR BIVEURSNS 2411i FS13 26DD -0 1 \. / \ 7, • \ GROUP GROUPS \ / co 4041H IJUALS.3S2 \ ..„ S.S. KICK PLATE S.S. KICK PLATE \ 1 CLOSER LCN 1 3 SILENCERS GLYNN-JOHNSON SR64 ADA DECAL \ / \ / r.„ PER DOOR PER DOOR 1 VIEWER IVES U700 B26D US26D \ / HARDWARE HARDWARE > \ 3 HINGE STANLEY FI3E1179 J _I_ \ \ , v - ' , CNI.,, ... • \ \ \ 10 PROCESSING AREA 1 PASSAGE TRILOGY DL2700IC-T2 BY GC TYPE "An TYPE "Cm TYPE n[ye TYPE PP PP IVES ow x 1 DOOR STOP FS13 2 KICK PLATE BURNS 24"H US26D US32D ROWNG GRILLE iN9ERQW3BLE1 1 CLOSER LCN 4041 CUSH AL 3 SILENCERS GLYNN-JOHNSON SR64 B26D FINISH F.O. WALL < 11 EEC. ROOM 1 DOOR HOLDER ttfRilLEY rittb US26D , LAN 1 LOCKSET BEST 73KC-7-D-15DS3 626 Project No. 44122 21-2" 31-0" 1 DOOR STOP NES FS13 US26D itiVARIES,, vr TEMPERED 31-8" ELEVATOR MACHINE RCOM •I' 1 CLOSER LCN 4041 CUSH AL MEI STARPHIRE CLEAR KICK PLATE BURNS US32D Scale AS NOTED EMS Iglimml 01111:BI Illgaim GLASS OPEN / \ 2 3 SILENCER GLyNN-JOHNSON s24Rff6H4 WALL MOUNTED / 1 LHOCINGKSE ET L-1 5 H-VIN 6U2S626D DrawnBy: DM/AN 3 HOLLOW 12 TOILET ROOM / HINGES , METAL DOOR > / Wof OCCUPANCY INDICATOR BSTETNLEY 4FB5BH1-709- PTD. \, itc, 1 1 '? IVES FS 1 3 4041 H US26D AL AT ELEVATOR MACHINE ROOM ONLY DOOR STO KICK PLATE LBcUNRNS 24"H US32D WOOD DOOR , Pe In T.O. PLATFORM / g' Iiirl 11 I 11 ".' c WITH PLANKS \ 7.„,... 3 GLYNN-JOHNSON SR64 \ cr, , PANIC HARDWARE-/ SILENCER 1 SMOKE SEAL PEMKO 588W AT ELEVATOR MACHINE ROOM ONLY 12 \ I R:VM\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220_A03.d , in DOOR LOCK, S.S. KICK PLATE 13 JANITOR 3 HINGE STANLEY FBB179 US26D US32 E._ i • r BEST I.C. CORE PER DOOR 1 LOCKSET BEST 73KC-7-D-15DS.3 N ROCKWOOD K1050 US32D 41 CD HARDWARE 2 KICK PLATE n raving Na. ■, 1 DOOR STOP NES FS13 US26D 42" " tS 3 SILENCER GLYNN-JOHNSON SR64 DOOR SCHEDULE N 1 CLOSER LCN 4041 CUSH AL N-,- TYPE sops TYPE "G" TYPE 'H" TYPE a ja TYPE "Km _ 1 DOOR HOLDER IVES FS446. B260 FINISH AND DETAILS 2 ESTIMATED AT 1-1/2" PAIR HINGES DESE6168E6 14 FITTING ROOM 1 LOCKSET WITH Ala: STRIKE US26D >, • 0 1 DOOR STOP NES WS402CCV US26D BY GC ,:, *it 1/4•=11-011 .. -c, DOOR TYPES 7 HARDWARE SCHEDULE I I 1 CU +-' tic2 va. ... AO.3 pSTLAOT EP 0 C 0 19 DD BB AA 0 0 :;111!'lliFill1111!!''dill/, 11/11! ileac of <8. itt -7 a il H US220 r " WASHINGTON SQUARE 44 WIDE CLEAR ., I EGRESS PATH TO TENANT A BE MAINTAINED 9 S.W. WASHINGTON SQUARE THROUGHOUT .`'. , i `` " " SUITE H08 ►.� ►�' - . iii EAT 02 ... ._. ::. . . .. .. : - .. .. ..- � PORTLAND, OR 97223 I CLASS: RED ,i ' ' iffffilli . -.. --- 1__. ' . , S Iliii.... 1 ****--w***--. : jtil.i.. .•17;°;;— , ,,,gyp, EXE. 9s. H&M US220 11116S1921 :-;: '/!. IbMIIIIIIIIIF _ 9585 S.W. WASHINGTON SQUARE Q OPEN f BELOW PORTLAND, OR 97223 rmillill ----. s ���.:... p�,_ - ..... .. 1 1 / i I ''''''-.-.--- ,i . ` 327sf T__E'`t AT 1g'-4 AFf. y *1 -i-. !I' - i ,-, .' ie 4\ 10 '■, 4 ,II 144, Ir CT'S ALAMEDA, r / 44:st ea) ea) elE) (.4:.?) -c/ .- 0. , ..:„. ./.'. ' 'V-'''oiai 41/:-::":::''''::: M --- r v, y- bi ' dal i.:,,, 3B :_+ ► I! lam_ _ _ ► - N —_ _ r° - r. K , w iat a [ , Osf 088Sf y U .al :.:::: *.f.' :iiii:, k r- ...... 1 I N cm ,-we• ' .! ' _ S' X04 i� . . INE1,16DEIE r 6391 5sf 1 30 TENANT N.I C EXIT f1 u ■� �v � l 1 T [ - _. 3 _ I 926sf 1 26sf 800sf r,, 800 [ EXITING REQUIREMENTS EXIT SUMMARY 1850r I C�► l I I► I I 1 1 OCCUPANCY GROUP: M I 'IF �t��gi® I n� ta � � — _ i 'i$ a is. L_ ' r.1-'1 x'a [ aea yr - .-rssyr -'a SECOND LEVEL. MEZZANINE; I�F77ANINE= SECOND LEVEL: �I ,► s02sf„ } •1�■�- I -I SALES AREA: STOCK ROOM / PROCESSING AREA: STAFF AREA: EXIT # 1: EXIT 3: _ _ — _ -- ----- GROSS AREA: 7,700 SF GROSS AREA: 1,858 SF = — _.I v_ _ "� I I Jul�� � iii It_ --- WE� I 1 r ��{ - ; I GROSS AREA. 233 SF OCCUPANTS SERVED. 257 / 2 129 OCCUPANTS SERVED, 26 .r, OCCUPANT LOAD FACTOR: 30 OCCUPANT LOAD FACTOR: 300 OCCUPANT LOAD FACTOR: 15 D(IT WIDTH REQUIRED: 129 X 0.15 = 19.35” EXIT WIDTH REQUIRED: 26 X 0.15 = 3.9" :- -- - ' - -- c sF —. _ ' �, f __OCCUPANT LOAD: 257 OCCUPANT LOAD: 7 OCCUPANT LOAD: 16 EXIT WIDTH PROVIDED: 36" EXIT WIDTH PROVIDED: 44" I-: �1: "'", 1 2a �f _. _.-.__..,_ r t EXITS REQUIRED: 2 OFFICES: TOTAL (SECOND FLOOR): I EXIT 4: r._..A_ ..__. - ___ ? ' _ �T _ �.-EXITS PROVIDED: 2 GROSS AREA: 269 SF TOTAL OCCUPANT LOAD: 7 + 3 + 16 = 26 EXIT 2., = _ — .1. ,,III!__ OCCUPANTS SERVED, 257 / 2 = 129 OCCUPANTS SERVED: 26 + 129 = 155 __ _ �,� — .i;. E' '`l'iE�l l ® - OCCUPANT LOAD FACTOR: 100 EXITS REQUIRED: 1 " " I I ,,,,,, Itpllllllp111�� lCfiti'II111'+■ EXIT WIDTH REQUIRED: 129 X 0.15 = 19.35 EXIT WIDTH REQUIRED: 155 X 0.15 = 23.25 I I i i Ras • OCCUPANT LOAD: 3 EXITS PROVIDED: 1 44" ,,- � a � ' Dennis Heath, A r c h i t e c t D(fT WIDTH PROVIDED: 36 EXIT WIDTH PROVIDED: 44 >ti ' ' i �,1.�>� ?�►n ;! _ s _ - ''" sF 2410 Mariner Square Loop _� I i' ' K 0 HOUSE Ros ' i1_ Alameda, CA 94501 1116"=f-0" r�- ��� �,.��_.,,�� _� SECO 0 � 1270 s��s� EGRESS PLAN - MEZANINE & SECOND LEVEL 3 �:: T I [ �. _ - _ Pin, * �,.lr'�til 2 24sf 2,477sf 3,30 f 2 1 4sf 1201 1180 gi' in ►: Lug _ 4,51 SF -- I I MAXIMUM ALLOWABLE PATH OF TRAVEL = 250 FEET OP ' — - ,Wit*A , I ' .,,,,n—14117 Drawings and written material appearing herein constitute original I:' — — fi t- t _ I and unpublished work of the Architect and may not be duplicated,0 0(111) CD �' `��' �` '` — :452008f �- ' � ®IP used or disclosed without written consent of the Architect D 1--1- � _ c DH ARCHITECTS- 2010 D <BB.9 �'8�'f' O r " ,I � f�* .� �73sf Ss 8sf . .9sf :�r�1 1 798sf,4 I I I I 1 I I II I I I I I 4,010 SF I QAQC N./8 5,OQ8sf fi,947sf 1 I' No . Dote Issue ` a 1� 1V---- t �� 05/28/10 100% SET :!: 1-\` 44" WIDE CLEAR ' \ F If 1,572 sf r}-' 1 i I I l "�,�` _ — 05/28/10 VT PACKAGE EGRESS PATH TO TENANT IVl I,' f' l I I — 1 _ ._- _ I _ p _ u.>s ' f - ®IIIIIlIIII� EGRESS MAINTAINED — x " .._ .... ►�•�.■ ._...�wn.�■. s — /,A � �� �,•.r , -1 ! �., �r �. ��i-`- y — �. �� �': �'�� D SET I 07/02/10 100%00 COMPLETE THROUGHOUT - . _- 38.3 ' 1 -._ SALES ti 07/28/10 LANDLORD SET II 08/13/10 PERMIT BID SET iii- 38 1 NIE II _ _ — — ', ..��. i I—. t II I I 0/ !7 1115' r:.1 , I 2 '' X01 11 -l; l,", _ 43 SEpp'�'` NI ill � L L II i L R._. 41"....■a A a 1.1ii k Cl°0) 0' xi r 4BEA..-Jia , - 1 ■--- : lir 1, .. .... 3fi9; iiiI XI 4111 • .... .. .. .. II ---- ■ Ii - I ' 36 (I) TENANT NM Project No. 44122 S c a l e AS NOTED EXITING REQUIREMENTS EXIT SUMMARY D r a In B y: DM/AN OCCUPANCY GROUP: M t= e FIRST LEVEL: SALES AREA: EXIT I 1: EXIT 4 2: R:\HM\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220—A04.d GROSS AREA: 9,443 SF OCCUPANTS SERVED: 315 / 2 = 158 OCCUPANTS SERVED: 315 / 2 = 158 OCCUPANT LOAD FACTOR: 30 D(IT WIDTH REQUIRED: 158 X 0.15 = 23.7" EXIT WIDTH REQUIRED: 158 X 0.15 = 23.7" Drawing N o. _ tan OCCUPANT LOAD: 315 EXIT WIDTH PROVIDED: 27'-6" EXIT WIDTH PROVIDED: 44" ° EXITS REQUIRED: 2 o EXITS PROVIDED: 2 SITE PLAN & N N EGRESS PLAN O, Q T a ..-. 1116"=f-0" N.T.S. _. EGRESS PLAN - FIRST LEVEL 2 SITE PLAN 1- A 0.4 ._ TAG DESCRIPTION DOSING DEMISING WALL G.C. TO PROVIDE 1 LAYER 5/8" TYPE "X" GYPSUM BOARD OVER (E) METAL STUD AT TENANT SIDE WHERE GYP. BD IS MISSING, V.I.F. PROVIDE IDENTICAL MATERIALS AS REQUIRED TO MAINTAIN FIRE RATING AND ACCEPT NEW FINISHES. mum ...,::...2�1•IOIJR-�.RATED WALL 3-5/8" METAL STUDS W/ 2 LAYERS Of_.5/8" TYPE "X"`GYP. BD. ON BOTH SIDES OF STUD, TIGHT iiii DECK. 0.3: .RATED WALL 5/8" METAL STUDS W/'f LAYER O 5/8" TYPE "X"'GYP: BD. ON BOTH SIDES OF STUD, TIGHT TO DECK. _.7*... NEW FULL T PARTITION WALL (GYP,BD.ONLY) 3-5/8" METAL STUDS W/ 5/8" GYP. BD. ON EXPOSED SIDES OF STUD ONLY. G.C. TO USE 5/8" r WATER RESISTANT GYP. BD. AT WET AREAS. METAL BACKING TO BE USED FOR PROCESSING AREA & TOILET ROOM FIXTURE INSTALLATION, SEE 10/A6.0 U S 2 2 0 ��� NEW FULL HE GHT PARTITION WALL (GYPBD AND PLYWOOD) WASHINGTON SUARE 3-5/8" METAL STUDS W/ 5/8" FIRE RETARDANT TREATED (FRT) PLYWOOD AND 5/8" GYP. BD. ON BOTH SIDES OF STUD IF EXPOSED. 91585 S.W. WASHINGTON SQUARE SUITE H08 .m1 NEW FULL SIT PARTITION WALL(WARDROBES) PORTLAND, OR 97223 ill 3-5/8" METAL STUDS W/ 6" (5/8" THICK) FIRE RETARDANT TREATED (FRT) PLYWOOD STRIPS AS SHOWN ON WARDROBE FIXTURE DETAILS. G.C. TO INSTALL CLASS: RED 5/8" GYP. BD. ON OPPOSITE SIDE IF EXPOSED. SEE A7.1 • CO DD 4" BB.9 BB.1 BB AA.1 A A z.1 NEW FrrTlPlc3 ROOM PARTITION ii - PLYWOOD & 5/8" GYP. BD. ON 2 1 2 METAL STUDS W/ 5 8 FIRE RETARDANT TREATED P 5 BOTH SIDES OF STUDS. TOP OF PARTITION TO BE AT 8'-0" A,F.F. VI .A.- :. ..::..:NEW PLt,lltl WALL 6" METAL STUDS W/ 3/4"::FIRE :REt DENT TREATED::( T)"::PLYWOOD AND 5/8" WATER RESISTANT GYP. BD. ON :BOTH SIDES OF"STUD IF EXPOSED ii z PEW RED WALL WesS Mati.$ 5/8" GYP. BD. OVER 7/8" HAT CHANNEL SALES AREA SALES AREA ill Mit 1-2--- A5.0 1-HOUR ELEVATOR SHAFT j I °11114.4 Mail N1C. 19 A4.0 OVER C-H STUD (24" O.C.) AND WITH ONE LAYER OF �, - , ONE LAYER OF 5/8" TYPE "X GYP. BD. 1 , , ,�ti SALES AIWA �►"'- -' - - - """ 1" TYPE "X" GYP. BD. (INSIDE SHAFT) PER UL #469. e'"� EM MEN!. .._ 3 -v- - - ==:: - - ---- -- ■�■ ---- - I <3 NOTES: ALANIEI�A. • - - CA - L-I _ 1 - I ®®�� o - FOR WALL INFORMATION SEE A6,0 •• cs* - MAXIMUM HEIGHT PERMITTED FOR A STUD WALL WITHOUT USING DIAGONAL BRACING IS 14'-0" A.F.F. ' '%..C" 1 2 I , I I ^ sill,' I 1 _ z F D 33 / ` 1 TYP. OF 2 BAIT INSULATION USE: R 11 SOUND ATTENUATION BAIT INSULATION AT ALL OFFICE AND RESTROOM WALLS, U.O.N.0 E I (11 F ( )'© DISPL Y A� I �TYP. Fro). I I � _ ,_� a 1_:a���.. TYP,:� I • 1 ` .- -.. I DIY. BLACK 11 ..1 TYP. TYP. I I I WINDOW #1 .111 _ ..�, �- � .� ® � -- -- -- _ _ _- - III RYDAY II�i i�ll� �[,�I l _. (3*ii.{ ������■ ,_ -, �� PARTITION LEGEND _ 3 '�� _ 1 1--mi n ®TYP. I I rm. 1 ' 11 I I I BOTH SIDE �. 1 �I 10 6,5 I I '' m ® 1 LEASE UNE, V.I.F. 11 1 © LAD. DENIM BOTH Mk I �-.� -. 37.9 1 I -Lilik, 1 A /F)Tr. I I r III I I Q I I /j►M EXISTING DEMISING WALL 3:_= =- - - ."„ SIDES A41, �- �!'■� 2'ma ..,- .... .... - . D :1.1 6 ® r" -► 0 I , 12 6 EXISTING NEUTRAL PIER TO REMAIN. GC TO VERIFY ACTUAL CONDITION, PROVIDE S.S. FINISH AS INICATED. 1 111, ' I A4.1. 3 Mk Ali r ril � IdE..ROOM 1 E - E 4,1 A4.1,• 1 n EXISTING COLUMN TO REMAIN. TYP. ALL COLUMNS. GC TO VERIFY ANY (E) FOOTING FOR COL SIZE do LOCATION _ I T I Dennis Heath, Architect um milli -�'! I QL I I I I STOREFRONT WINDOW SYSTEM - 5/8" CLEAR TEMPERED STOREFRONT GLAZING, TYP.I i �"�:` A4.1. I I IT 2470 Mariner Square Loop I I16 -- STAINLESS STEEL PANELS I ,� 1 F 1 A5.0 6 Alameda, CA 94501 I �- 4.1 I I 16 AREA - NJ.C. 19 I - - II EXISTING STAIR FRAMING. G.C. TO INSTALL FINISHES AND COORDINATE HANDRAIL INSTALLATION 1 1 Q�1/. FAD _; ;AVE... I I 12 s,443ESO. A �. EVERYDAY I � 20 hIEIAf,::GLASS:::GUARIL,..SEE:::DETAIL2 ABOVE MID 11111 I nP. AM-- 1 I-- - 1- Drawings and Britten material appearing herein constitute original A4.0 I I I TYP. - - -j A4.o pi...:G:C .TO.:::DEMO::.DEMISIING:::WALL.::FOR::(M):::.EXIT::. ?R:::::: N.....-...../ I I °_ I SIDES �✓ and unpublished work of the Architect and nag not be duplicated, 1 1 11111 ' LL I 011I.8LACK i_ J_. I 11 ENTRY SLIDING won / UNE OF ROWNG GRILLE used or disclosed without written consent of the Architect I 111 I�� 2 <�TYP.e _ - - - - r, - G.C. TO WRAP COLUMN TIGHT AS POSSIBLE, TYP. ON COLUMNS, U.O.N. '�J 11 I-i-i °1!�i ll �' -��E E i _ :::_ _ ��` 4 Uti Q A Q C TYP, ALIGN WALL SURFACE AS REQUIRED__1 BOTH 12 I 6 12 19 l �� 33 E I SIDES �, No . Date Issue `,��I F El Eg - 36.9 13 BUILT UP PODIUM:::/ DISPLAY PLATFORM, SEE DETAIL 4/A5,2 19 11 El 12 I 05/28/10 100% SET �a 36 790 SQ. FT. I 1114i i An a nr�aa ---� --�--- SOFFIT BULKHEAD ABOVE. REFER TO RCP FOR HEIGHT• 1 �� F 1 I, 'I I 1 I 14 / 05/28/10 VT PACKAGE Ark j A4.1, I FLOOR MOUNTED DUPLEX RECEPTACLE, MAX. 16-0 0,C. AT PLATFORM DISPLAY AREAS. SEE 4/A5.2 07/02/10 100% COMPLETE SET 1 I, �►11 1-.Tq I -- D ,I - - -' 6 ( I,�u VII � 1 I ___! ,��•d�.� � -. 1. �I �1-�__ 07/28/10 LANDLORD SET 32 -� Q TYP. I F NP, WINDOW #2 [Ti NEDAP PEDESTAL EAS SYSTEM FLOOR MAX SYSTEM, TYP. FOR (3). 4.1� A4.1 ( � I 08/13/10 PERMIT/BID SET �Il III, DIY.ACC,+ ..-,. IA, t I I 1 I I El I UND.:::.DOOR....FOR.:::WAI. .BOX.,ACCESS.::.:::: 36 �k I ri!I UNIDERW I I F E I I 1 I ::.17::.::::.. . - .I� ,I 35 34 E I I I I I TYP,1 I D 41 I I, I I *EI _ _ _ L - - Fil::::.fLflOR:::MAT:::SEE:::A2:2cr:::FOR QVERIi::::.{31MENStONS.Il . 24 �_ - I il m EXISTING X-BRACE TO REMAIN ni - y�I A F . LQ� I I, F a , ' IN H&M SIGN. SEE STOREFRONT ELEVATIONS A5.0 FOR TYPE. SEE SHEET A52 FOR MORE DETAILS.bp MAUL=tom 36 p 1 , 361 20 g El TYP, I I► TYP, r El 'TYR OF (2) 21. EXISTING OPENING FOR DUCT::. 1 e - --- - - - _ __ _( IC --I i -_ _ 1 -- iiii EXISTING ELEVATOR OPENING C.C. TO COORDINATE EQUIPMENT INSTALLATION. SHEET A9.1 e ee - ti\--- E--- ...... I 36 23 EXISTING ESCALATOR OPENING ABOVE. G.C. TO COORDINATE EQUIPMENT INSTALLATION. SEE SHEET A9.Oa $IAA Amman pill WARDROBE FIXTURE SYSTEM. SEE SHEET A7.1 rg. TENANT-Pao Ali 1 25.. .I L L U M I N A T E D:P O P-O U T:.W :P A N E L...F I X T U R E A N D D E T A I L ..LIGHTING. A..9...39, A4.0 WALL FRAME FIXTURE SYSTEM. SEE SHEET.A7.-1. 27 FREE-STANDING:::WALL::FIXTURE:::SYSTEM,:::TYP :SEE:::INTERIOR:::INSTRUCTIONS. 28,,.,,,,FLOC:CABINET:FIXTURE::SYSTEM _...29.. WALK=IN==CLOSET=FIXTURE==ASSEMBLY Project No. 44122 FIO ....FLOOR UNIT FIXTURE REFER TO FIXTURE PLAN FOR LOCATIONS -SEE DETAIL-5/A71 :.:31.... wog„.SELF„FIXTURE REFER TO FIXTURE:PLAN FOR:::-LOCATION::::. Scale AS NOTE D 1-3T1 REAR SERVICE DOOR BUZZER MOUNTED 3'-6" A.F.F. SEE POWER PLAN. MIRROR, SEE FIXTURE PLAN FOR TYPE D r a w n B y: DM/AN 3 I E- 1 CASHWRAP / BCKWRAP. G.C. TO PROVIDE F.R.P. PLYWOOD BEHIND BACKWRAP AS REQUIRED. SEE DETAIL 9/A6.5. O Elb 35 ACCESSIBLE CASH DESK R:\HM\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220_ 20a.d 36 PORTABLE FIRE EXTINGUISHER. MAXIMUM TRAVEL DISTANCE FROM ANY PART OF THE STORE TO THE FE. CAN'T EXCEED 75. FINAL LOCATION TO BE APPROVED BY FIRE MARSHALL Drawing N o. o N NOTES: CONSTRUCTION PLAN - REFER TO A2.Ob FOR CONSTRUCTION PLAN NOTES FIRST LEVEL N a, v 9. a .9 CONSTRUCTION PLAN - FIRST LEVEL �$�°� 4 CONSTRUCTION KEYNOTES - i Ana ..., ,T_ 1. G.C. TO V.I.F. ALL (E) DIMENSIONS AND REPORT ANY DISCREPANCIES TO ARCHITECT AND OWNER BEFORE COMMENCING CONSTRUCTION. 2. ALL DIMENSIONS TO BE COORDINATED IN THE FIELD WITH H&M AND ARE SUBJECT TO (E) CONDITIONS. DIMENSIONS 7/11/14/1/ MARKED AS EQUAL (EQ) APPLY ONLY WITHIN A GIVEN STRING OF DIMENSIONS UNLESS OTHERWISE MARKED. 3. ALL H&M SUPPLIED FIXTURE LOCATIONS AND DIMENSIONS TO BE VERIFIED WITH H&M PRIOR TO CONSTRUCTION AND INSTALLATION. 4. G.C. TO VERIFY ALL DIMENSIONS OF MILLWORK, FIXTURES, AND FITTING ROOMS WITH H&M PRIOR TO LAYOUT. 5. DIMENSIONS ARE TO FACE OF GYP. BD. UNLESS OTHERWISE NOTED. DO NOT SCALE THESE DRAWINGS. USE WRITTEN DIMENSIONS ONLY. SUBMIT TO ARCHITECT ANY DISCREPANCIES FOR CLARIFICATION. 6. ALL PLYWOOD BACKING/BLOCKING IS F.R.T. G.C. IS RESPONSIBLE FOR SUPPLYING ALL BACKING AND BLOCKING AT ALL WALL AND CEILING HUNG FIXTURES AS REQUIRED BY CODE AND STRUCTURAL NECESSITY. G.C. TO COORDINATE WITH H&M. 7. G.C. TO VERIFY WITH LL THE MAXIMUM DEPTH OF ANY PENETRATIONS OR ANCHORS INTO THE SLAB BEFORE THEY WILL REQUIRE LL APPROVAL 8. G.C. TO PATCH AND PAINT ALL GYP. BD. AND EXPOSED AREAS AT (E) WALL & COLUMNS AND MAINTAIN (E) US220 FIRE RATINGS. WASHINGTON SQUARE 9. ALL FLOOR ELECTRICAL BOXES TO BE INSTALLED FLUSH WITH NEW FLOORINGS AT CASHWRAP AND AT FIXTURES WITH POWER. SHOWN ON ELECTRICAL SHEETS. 915$5 S.W. WASHINGTON SQUARE 10. ALL RECEPTACLES TO BE CENTERED AT ALL LOCATIONS. SUITE H08 11. IT SHALL BE THE SOLE RESPONSIBILITY OF THE G.C. TO TEST MOISTURE CONTENT OF SUB FLOOR PRIOR TO INSTALLATION OF ALL FINISH FLOORING MATERIALS AND TO MAINTAIN PROPER TEMPERATURE AND PORTLAND, OR 97223 HUMIDITY LEVELS PER MANUFACTURER'S SPECIFICATIONS. CLASS: RED 0 (ID 1. FIRE LANES TO BE ESTABUSHED AND/OR MAINTAINED. D D BB 9 BB.1 B B AA.1 .' Q Z.1 2. ESTABLISH & MAINTAIN 20' OF ACCESS TO ALL STRUCTURES FROM THE PUBUC ROADWAY DURING CONSTRUCTION. 3. PROVIDE A NEW KNOX BOX IF ONE DOES NOT EXIST ON BUILDING. MOUNT BY MAIN ENTRANCE 4' - 6' 1'- 1 4' 14'-8" 20'-0" 20'-0' 20'-0" 20'-0" 20'-0" 20'-0" 4'-3 3/4' A.F.F. PROVIDE A DOOR KEY FROM TENANT AND PLACE IN KNOX BOX. 4. INTERIOR TENANT NOTIFICATION SHALL BE PROVIDED WHEN MONITORING OF THE FIRE SPRINKLER SYSTEM IS PROVIDED. TENANT IMPROVEMENTS: INSTALL 1 HORN-STROBE ABOVE THE MAIN DOOR OR WITHIN 3 FT. OF THE 56'-2 1/4" '-3 3/4' MAIN DOOR FOR INDMDUAL TENANTS. WHEN A COMMON AREA IS PROVIDED SERVING MULTIPLE TENANTS, INSTALL LEASE LINE TO LEASE UNE r LEASE NE TO LEASE UNE r STA POINT 1 HORN—STROBE IN THE COMMON AREA ABOVE THE MAIN DOOR OR WITHIN 3 FT. OF THE MAIN DOOR. (THESE FOR YOUT REQUIREMENTS SHALL ALSO APPLY TO SPACES COMMONLY REFERRED TO AS 'VANILLA" OR `WHITE' SHELL TENANT 11'-6" 39'-9 1/4" 4'-0• 34'-11 1/4' 4*- • 35'-7 1/2" -9 3/4"2'-6" SPACES AT TIME OF SHELL FINAL). MULTI-STORY BUILDINGS SHALL REQUIRE A MINIMUM OF 1 HORN-STROBE / F ,k r , / r rr / r PER LEVEL THIS REQUIREMENT APPLIES ONLY IF THIS IS THE 1ST T.I. IN THIS BLDG. OR IF OTHER SUITES IN I i'fri, it 1'-7" THIS BLDG. HAVE INTERIOR NOTIFICATION. (SUBMITTAL & APPROVAL OF SHOP DRAWINGS REQUIRED) NOTE: THIS EQ. 14'-10 1/4" 2'-11 1/2' 14'-10 1/4' EQ ,D 14'-10 1/4" 3'-4 1/ " 14'-10 1/4' .1" REQUIREMENT MAY BE INCREASED BASED ON OCCUPANCY TYPE OR AT THE DISCRETION OF THE FIRE CHIEF. THIS y r r y •f r r IS NOT INTENDED TO BE AN ADA COMPLIANT SYSTEM. (REFERENCE: SCTDL REVISED CODES, SEC. 903.4.2) Meta V'�'�I� ENS AI SALES AREA I SALES AREA— s A5.0 e' 1 ill idi et:- ` ! MAGEE :r.,,,... to 1 'I ,�r ,--) TENANT-N.LC. - — — — — — — — — — e . •� — r — —— — — — _ --------- -- --—I® I— 38.3 ' � . _if. EN:sue _ ———- -- - -- ----------- ---- — a. —-- _ AL.AI EDA. CA 1 . ( I: i;: set t=s e-n s o I? I .1 I I 1 1 ..1.-: 47:8 �.' BLACK — OF P Dl im EVERYDAY .D.. a,z.t1.,. 1• DISPLAY . ill ■•• a ;4 1 WINDOW #1 c 1 111 I41�dI �Eirdl - 38 � . iI iii L� �. I I II • I 1 , 1 1 LACE DENIM , �� •�" \ — �- =rte 1 . W! ` n M Q' M cH E . r-.... _ Dennis Heath, Architect �. — — II II I 1 0 -� I - - - I I 7410 Mariner Square Loop M II Alameda, CA 94501 I I o 0, I AREA- IV1C, 1 I I I I- I I—— — — -- — - — N W DN. RED • = I ABOVE —— — -- I LAD. EVE11'DAY OPEN ABOVE I = I I I 18`-21/2' I In W I I 16'-10 3/4' •iiinni I I - 7, _ II' — — — ' °I o Iraaiwgs and written material appearing herein constitute arigiaal 0 1 �� II II 2' 9 ^ = and unpublished work of the Architect end coy not be duplicated, I ' _ I ON. BL CK I O,N, used or disclosed without written consent of the Architect " I I �_ __ __ — ___—_ I — L. — __I Ca—. — — — �� — ODH ARCHITECTS- 2010 inlill .c.? --EL ---115• — — ->_ IN 1 Wilil i .. — t • CD 4178111 __1 1 QAQC � - f3/�4 19-0 1/2 —5 3/c11 1 No Dote Issue ' ''' 22`-11' ca 36.9 • 1 " c - I "' �� _ , ' 05/28/10 100% SET Lituagia, r)...I 11 ( I ill , ^ 1# (1 05/28/10 VT PACKAGE I ........ I I. 1 (1 07/02/10 100% COMPLETE SET I ____10_\_ = l III ��11/. ACS + �. cL= , �. :.! .A.• !z; 1 �_'�_ 1 v-, ' f2 07/28/10 LANDLORD SET CO aill 1 i °? 4 1/4' 12'-8 1/4' 2'-11 1 2'II 12'-8 1/4' 41-8 1/4 08/13/10 PERMIT/BID SET 1 N I I I► o •, � it r I I r 1 `� a ■I ICI 1 I _„,,,, 1 ,.. '`, Z'i 1 1 -4 °° l� i en t I Igli , 1 1 1 i = 1 MIN. �I � _ :66.1 MALL — "' _ I CORRIDOR _ I I I► N , . I ..'' I ININ I L aill III I I — —— ——— — ICI— —— —— —— CI �� —4...—� _-7_ ' .ta _......—......—...........±............- .....-13pt---..4"""e"=jl a� _,. SALES AREA Mina 1110811E SIAM SALES AREA (� l-.... -r ... A2.1 b �-'2" 1' F.D. 2,'—Oh—EQ. 16'-9 1/2" 2' 11 1/2" 17'-0' EQ. , —EQ. 6'-6" —5' 16'-4 3/4' 5")/ 8'-6• EQ;�, Project No. 44122 ■ Scale AS NOTED DrawnBy: DM/AN E a C g, a R:\HM\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220J120b.d a N Drawing No. 0 ED N DIMENSION PLAN FIRST LEVEL 0, T o a, DIMENSION PLAN - FIRST LEVEL V8T 4 CONSTRUCTION NOTES - 1 ..- g _ , A2 .0b TAG DESCRIPTION EXISTING DOMING WALL :111!:11111F1F11111111/11! G.C. TO PROVIDE 1 LAYER 5/8" TYPE "X" GYPSUM BOARD OVER (E) METAL STUD Al TENANT SIDE WHERE GYP. BD IS MISSING, V.I.F. PROVIDE IDENTICAL MATERIALS AS REQUIRED TO MAINTAIN FIRE RATING AND ACCEPT NEW FINISHES. Imumill 2410uR RATED WALL IS 3-5/8" METAL STUI:)S W/ TO DECK. D. ON BOTH SIDES OF STUD, TIGHT 1-HOUR RATED WALL ill BD ON 3-5/8" METAL STUDS W/1 -LAYER-OF 5Am,ME-"X" CV. . BOTH SIDE... OF STUD, TIGHT TO DECK Iiimmi■No■■■■■=1 ALV.A VIEW FILL MEW PAFITMON WALL (GYM.ONLY) ii 3-5/8" METAL STUDS W/ 5/8" GYP. BD. ON EXPOSED SIDES OF STUD ONLY. C.C. TO USE 5/8" WATER RESISTANT GYP. BD. AT WET AREAS. METAL BACKING TO BE USED FOR PROCESSING AREA & TOILET ROOM FIXTURE INSTALLATION, SEE 1 0/A6.0 US220 ...h. NEW FULL HEIGHT PARTITION WALL (GYPBD AND PLYWOOD) WASHINGTON SQUARE ii 3N3-5w55:88°R)MIALLET:ALHEIGHTS;UDDSspART=NW: 256/..tA8("5YE/FIRS8WR.EALLT°HRFIETC0N5KI:SAF0FroBE8Dn.AF.:IYPEET TRRETEANAR-IIEDANT)DGYP(F.RT:RBEAPTLEYWD PLYWOOD AND 5/8" GYP. BD. ON BOTH SIDES OF STUD IF EXPOSED. 9585 S.W. WASHINGTON SQUARE SUITE H08 -.S.. PORTLAND, OR 97223 IIPLYWOOD STRIPS AS SHOWN ON WARDROBE FIXTURE DETAILS. C.C. TO INSTALL CLASS: RED - I 5/8" GYP. BD. ON OPPOSITE SIDE IF EXPOSED. SEE A7.1 _____ 0 0 DD 110 BB A A 0 0 lew FITTNG ROOM PARTITION - ill 2-1/2" METAL STUDS W/ 5/8" FIRE RETARDANT TREATED (FRT) PLYWOOD & 5/8" GYP. BD. ON BOTH SIDES OF STUDS. TOP OF PARTITION TO BE AT 8'-0" A.F.F. VAV A NEW PLUMBING WALL I 6" METAL STUDS Wf 3/4* FIRE RETAK0T TREATED (FRT) PLYWOOD AND 5/8" WATER RESISTANT mi I GYP. BD. ON BOTH SIDES OF STUD IF EXPOSED . . - MI !KM Ma 5/8" GYP BD OVER 7/8" HAT CHANNEL I SALES AFEA SALES AREA II Ask :11111111'111 1 ' I ALMAGOE I IN 1-HOUR ELEVATOR SHAFT t 11 A A . KIDS /BABY nattiLlia 1E11 A4.0 ONE LAYER OF 5/8" ME se GYP. BD. OVER C-H STUD (24" 0.C.) AND WITH ONE LAYER OF ' -'1!k ' , i Ar. T:11 ....,...44, • (--, SALES AREA Si A 1 TYPE "X GYP. BD. (INSIDE SHAFT) PER UL #469. t:14 .......3 ELEVATOR _____ I . .- - ... - alma _raw_ ---11111111■111111111111111111111111•11111 I NOTES: ALAMEDA,CA I, 1111111111111111111911 bo■ii....-Wmp...-„mii/Wirr j..40 rossime Imam. ms...Immo ramon.g r.-4- I I ....fi............, ,...-.-......iii,_[__, 1 - FOR WALL INFORMATION SEE A6.0 - MAXIMUM HEIGHT PERMITTED FOR A STUD WALL WITHOUT USING DIAGONAL BRACING IS 14'-OR A.F.F. '*(40F A.9.1 \ I - BATT INSULATION USE: R-11 SOUND ATTENUATION BATT INSULATION AT ALL OFFICE AND RESTROOM WALLS, U.O.N. N.........." 22 E E 1 1- Eil V, ii .....4,0 Ark n 6 1 imi 24 CI LI u ii, OMR MI MI 1111111111 M/11. ir• . t1115 - TYP. - - , ...._ _____ ...._ _ - - El 111 IN. or _,,,_______ _ - _ - - ,.. . ,- - , ill 41 . 10 1 1 _ TYP. PARTITION LEGEND I I - . ..... 1 .. ..m.....m.a--.....z.3:. _ __ _ . ..,,,, ,,,,,,,,. 40, .40.,. iii Nora Wririmm.....1 0-i■-iimiirmiiiii II iii ! A7.1 IIII III i MENS LO.G.G. • - / 1 MEM IHILM • t mmil.. „.■ 1---- LEASE LINE, V.I.F. 1 I Mil II I iil ,... in _ A-. 8 2 EXISTING DEMISING WALL 3 - EXISTING NEUTRAL PIER TO REMAIN. GC TO VERIFY-ACTUAL coNornot4,, PROVIDE S.S. FINISH AS INICATED. • ... ... ii m E3 U 101 8 28 Ark 6 AEI .1 on :_-__ EN INN N. -. '41 tt:.15 A41 -.1 e) I r.... Lk ..... 4111k Alilk ..- `4110 36 Ei ki....9 'EMMEN MN 111■111M IN ME 1111 IS MI 111 NUN EN , Me 11E1 ...■■■••• iwoir.... 7-e7;/.' A‘?.....1) - EXISTING COLUMN TO REMAIN. M. ALL COLUMNS. GC TO VERIFY ANY (E) FOOTING FOR COL SIZE & LOCATION 4 DII Dennis Heath, Architect MM AlElli Da - , E STOREFRONT WINDOW SYSTEM - 5/8" CLEAR TEMPERED STOREFRONT GLAZING, TYR r 2470 Mariner Square Loop .. kt: ,.+D.s c- 01 1 w ...1 = STOREFRONT STAINLESS STEEL PANELS Alameda, CA 94501 (2 Y4 E SiNLES_ABA. 4/;44101 D MAUI 'V ,,,, A9.2b rIA e 7,700 SQ. FT. 11111111111111f v. IMEN=1= n DOSING STAIR FRAMING. G.C. TO INSTALL FINISHES AND COORDINATE HANDRAIL INSTALLATION 7 ■-....., OPEN TO 1 1111 . I, ,BELOW Iiiiiiiin , , , ® p. mat III .4 ppEN TO I rahl caLlatiLKEIA. ---- I• 12 rm. p. , BELOW Fl NEW GLASS GUARD, SEE DETAIL /112\ 1711 Ma :•in I •II Li I S .s./.1 11111111111111111■111111■1111111111111111111110■111■1 A4.0 -I I 'A 74 Allik 1"1 f V III i = A4.0 I 9 G.c. To Dm DEmiswa wAu. FOR (N) arr pooR Drawings wad written material appearing herein constitute originul 19 aca 4. and unpublished auk of the Architect and may not be duplicated, ,-": -IFTITLIIri FIT used or disclosed without written consent of the Architect "....-..." 'V lil Or I C-47) 8 A4.1 I 1 rinipinuomie 1E:24 km..7..5.0.millomito 8 II III , A C.C. TO WRAP COLUMN TIGHT AS POSSIBLE, TYP. ON COLUMNS, U.O.N. C)0H ARCHITECTS- 20 10 111 0 BIM w■ li "-------aA..............----........... ; • . P 1 1 _... ___ 107";11 101"■11 We-4 l■-- 1 111;■11 1107.7411 Ila:;41 PE rill 110- 1 1103:211 10.-Mill 110-71"1 qzrLLLLjj Eg a 1:11,LILm 4%.ili■ QAQC Ell 8 ?All ITT A• LIGN WALL SURFACE AS REQUIRED 1 ral I il A athilatunt. Y1 Fag Ill 411 ±AGGL 1 1 2 ill BABY A\ EiTyp. { ...... pET l . ,,,,,, Ei 9 , . ,,,,,, IN 8 Nil 1 I 1 -3-1 BUILT UP PODIUM / DISPLAY PLATFORM, SEE MAIL 41A5:2 - 14 SOFFIT / BULKHEAD ABOVE. REFER TO RCP FOR HEIGHT Fi- Ft.00R MOUNTED DUPLEX RECEPTACLE, MAX. 16-0' 0.e. AT PLATFORM-DISPIN AREAS. SEE 4/A.5.2 No . Dote 05/28/10 05/28/10 07/02/10 Issue 100% SET VT PACKAGE 100% COMPLETE SET III ki.:9 In 1 111Pa F i- NEDAP PEDESTAL LAS SYSTEM FLOOR MAX SYSTEM, PIP. FOR (3). 07/28/10 LANDLORD SET CI III! MEM MENS III IIII Mit 08/13/10 PERMIT/BID SET III ill III El 8 .4.1. 6 A4.1. i, UNDERW I;7 1 I ifi I i i 1 ±Ign ...:.• ;Le/k IV UNDEBW. A 1 OLUBACC N-7-1 BLIND DOOR FOR WALLBOX ACCESS. 'LAM Ilii 1 of 1 Ill ilElli 4 T, _ 11 lil Ell ily , I TYP. 18- FLOOR MAT. SEE A2.2a FOR OVERALL DIMENSIONS. 111.44) ' r ID ri l' I I I 36 I I g 11 I -1111.. -1 mimaTh-i I 0 I ON. (MaL. • H N-1 EXISTING X-BRACE TO REMAIN A I I, 11111111111111 i i________ rIA Yi El El E El is:e. 1 pill P01 %SW- SIGN. SE STOREFRONT ELEVATIONS A&D FOR ME. SEE SHEET A5.2 FOR MORE DETAILS. 111 r IA T(P. rl A 1 1 V 111 I ■ TYP, LIT --.....- pl k 4 Al 91 9: mniiiiiiiiPiiiii II 1 F271 EXISTING OPENING FOR DUCT .....m.. ..m. ........ ,ii, 1 INIMIAMIIIIII Pill.I-SIM I MI I I-F"'.""'' ...dial!IT!.....r.%"'"Niill I Iiiiiii F EXISTING ELEVATOR OPENING G.C. TO COORDINATE EQUIPMENT INSTALLATION. SEE SHEET A9 1 ______ ____________ 36 Km I BABY Apiarair MEM Ell 1--23 D• OTING ESCALATOR OPENING ABOVE. G.C. TO COORDINATE EQUIPMENT INSTALLATION. SEE SHEET A.9.0a SALES AREA MAMA= SALES AREA 1011 IIII SIAM F-2-4-i WARDROBE FIXTURE SYSTEM. SEE SHEET A7.1 411111k A.9.213 Allik rgl ILLUMINATED POP-OUT WALL PANEL FIXTURE SYSTEM. SEE DETAIL 6/A7.1 AND MEP DRAWINGS FOR PANEL LIGHTING. •,........./ A4.0 ITC WALL FRAME RXTURE SYSTEM. SEE SHEET A7.1- liT1 FREE-STANDING WALL FIXTURE SYSTEM, TYP. SEE INTERIOR INSTRUCTIONS. F2T-11 FLOOR CABINET FIXTURE SYSTEM 29 WALK IN CLOSE]. fl)(1Jf.E SASS EMBkY. Project No. 44 1 2 2 30 ROOR UNIT FIXTURE REFER TO FIXTURE PLAN FOR LOCATION. SEE DETAIL 5/A7:1 171-1 Boot< sus RXTURE REFER TO RXTURE NAN FOR LOCATION Scale AS NOTED E REAR SERVICE DOOR BUZZER MOUNTED 3'-6" A.F.F. SEE POWER PLAN. F M• IRROR, SEE FIXTURE PLAN FOR TYPE Draw n By: DM/AN E Fsz CASHWRAP / BACKWRAP. G.C. TO PROVIDE F.R.P. PLYWOOD BEHIND BACKWRAP AS REQUIRED. SEE DETAIL 9/A6.5. 0 cr. 35 ACCESSIBLE CASH DESK 73 RAM\Projects\2010_Projects\44122 Washington Sq\Drawings\CIAUS22CLA20c.O N 12.6.] PORTABLE FIRE EXTINGUISHER. MAXIMUM TRAVEL DISTANCE FROM ANY PART OF THE STORE TO THE FE. CAN'T Lo EXCEED 75'. FINAL LOCATION TO BE APPROVED BY FIRE MARSHALL Drawing No. .. `c 3 OD NOTES: - REFER TO A2.0b FOR CONSTRUCTION PLAN NOTES , CONSTRUCTION PLAN _ - MEZZANINE LEVEL 1 .0, >, 0 -0 .,-_- , 1/81=1-011 _ -0 CONSTRUCTION PLAN - MEZZANINE LEVEL I 4 CONSTRUCTION KEYNOTES [ _ A2.0c 2 i g _ 1. G.C. TO V.I.F. ALL (E) DIMENSIONS AND REPORT ANY DISCREPANCIES TO ARCHITECT AND OWNER BEFORE COMMENCING CONSTRUCTION. 2. ALL DIMENSIONS TO BE COORDINATED IN THE FIELD WITH H&M AND ARE SUBJECT TO (E) CONDITIONS. DIMENSIONS MARKED AS EQUAL (EQ) APPLY ONLY WITHIN A GIVEN STRING OF DIMENSIONS UNLESS OTHERWISE MARKED. lit&M 3. ALL H&M SUPPLIED FIXTURE LOCATIONS AND DIMENSIONS TO BE VERIFIED WITH H&M PRIOR TO CONSTRUCTION AND INSTALLATION. 4. G.C. TO VERIFY NI DIMENSIONS OF MILLWORK, FIXTURES, AND FITTING ROOMS WITH H&M PRIOR TO LAYOUT. 5. DIMENSIONS ARE TO FACE OF GYP. BD. UNLESS OTHERWISE NOTED. DO NOT SCALE THESE DRAWINGS. USE WRITTEN DIMENSIONS ONLY. SUBMIT TO ARCHITECT ANY DISCREPANCIES FOR CLARIFICATION. G 6. ALL PLYWOOD BACKING/BLOCKING IS F.R.T. G.C. IS RESPONSIBLE FOR SUPPLYING ALL BACKING AND BLOCKING AT ALL WALL AND CEILING HUNG FIXTURES AS REQUIRED BY CODE AND STRUCTURAL NECESSITY. G.C. TO COORDINATE WITH H&M. 7. G.C. TO VERIFY WITH LL THE MAXIMUM DEPTH OF ANY PENETRATIONS OR ANCHORS INTO THE SLAB BEFORE H—_ .� ACC ACC THEY WILL REQUIRE LL APPROVAL. US220 8. G.C. TO PATCH AND PAINT ALL GYP. BD. AND EXPOSED AREAS AT (E) WALL & COLUMNS AND MAINTAIN (E) FIRE RATINGS. WASHINGTON SQUARE I 9. ALL FLOOR ELECTRICAL BOXES TO BE INSTALLED FLUSH WITH NEW FLOORINGS AT CASHWRAP AND AT FIXTURES WITH POWER. SHOWN ON ELECTRICAL SHEETS. p ,-f- I 9585 S.W. WASHINGTON SQUARE 10. ALL RECEPTACLES TO BE CENTERED AT ALL LOCATIONS. 11. IT SHALL BE THE SOLE RESPONSIBILITY OF THE G.C. TO TEST MOISTURE CONTENT OF SUB FLOOR PRIOR ef SUITE H08 TO INSTALLATION OF ALL FINISH FLOORING MATERIALS AND TO MAINTAIN PROPER TEMPERATURE AND PORTLAND, OR 97223 HUMIDITY LEVELS PER MANUFACTURER'S SPECIFICATIONS. p W CLASS: RED FIRE NOTES I) a) DD ID 1. FIRE LANES TO BE ESTABLISHED AND/OR MAINTAINED. BB 0 4111 AA 2. ESTABLISH & MAINTAIN 20' OF ACCESS TO ALL STRUCTURES FROM THE PUBLIC ROADWAY DURING CONSTRUCTION. 011 3. PROVIDE A NEW KNOX BOX IF ONE DOES NOT EXIST ON BUILDING. MOUNT BY MAIN ENTRANCE 4' — 6' A.F.F. PROVIDE A DOOR KEY FROM TENANT AND PLACE IN KNOX BOX., '-- ■2' 14'-8" 20'-0" 20'-0" 20'-0" 20'-0" 20'-0' —0' 4. INTERIOR TENANT NOTIFICATION SHALL BE PROVIDED WHEN MONITORING OF THE FIRE SPRINKLER SYSTEM IS PROVIDED. TENANT IMPROVEMENTS: INSTALL 1 HORN—STROBE ABOVE THE MAIN DOOR OR WITHIN 3 FT. OF THE 56'-2' &2f_p• MAIN DOOR FOR INDMDUAL TENANTS. WHEN A COMMON AREA IS PROVIDED SERVING MULTIPLE TENANTS, INSTALL LEASE UNE TO LEASE UNE LEASE UNE TO LEASE UNE 1HORN—STROBE IN THE COMMON AREA ABOVE THE MAIN DOOR OR WITHIN 3 FT. OF THE MAIN DOOR. (THESE ' START POINT ,, REQUIREMENTS SHALL ALSO APPLY TO SPACES COMMONLY REFERRED TO AS "VANILLA' OR "WHITE' SHELL TENANT ■ 32'_9" 3'-7• 23'-3 1/2" I• 1'I al SPACES AT TIME OF SHELL FINAL). MULT1—STORY BUILDINGS SHALL REQUIRE A MINIMUM OF 1 HORN—STROBE I PER LEVEL. THIS REQUIREMENT APPLIES ONLY IF THIS IS THE 1ST T.I. IN THIS BLDG. OR IF OTHER SUITES IN THIS BLDG. HAVE INTERIOR NOTIFICATION. (SUBMITTAL & APPROVAL OF SHOP DRAWINGS REQUIRED) NOTE: THIS I REQUIREMENT MAY BE INCREASED BASED ON OCCUPANCY TYPE OR AT THE DISCRETION OF THE FIRE CHIEF. THIS i 1 i A Y,. EQ. 12—8 1/2 3—3 1/r 12 8 1/2' EQ, 21 —1 1/2 Q 15-8 IS NOT INTENDED TO BE AN ADA COMPLIANT SYSTEM. (REFERENCE: SCTDL REVISED CODES, SEC. 903.4.2) '� Al 'w1 I I WALL ALIGNED WITH 11 �'I /r WARDROBES BELOW �� + , I II :, A AREA— SCALES AREA __ ''""' -r AtAMED&C:A TENANT-N1a ► �► mow•- J i � M1111111•11111�i , j� ilk I�� I ELEVATOR KIDS / BABY I I I �•, MIENS LO.Ct.II ,i_._L I III 1 ii Zi..,t- II i ii �� _ �- . _•ih1 r _ _ I II — E — h! L!■I_m :: - _ '� — — •M� ' 4 �►■4 . 1 s�■suess1r■s�■ns�ss : ►�4►M�►�4►_4►�4►�4►��- - . 1 # _ I -- ---- I I 1 I I 1 11 36'-11 1 1 2 — . —� —1; .r' i� —i s. i.. _- '� s. 40'-1 1 2" 3-6• I I. . I I ..... .. ..... .s�. .NI ._. A 1 I - 5'_p I • z ,� 1 ` ° Ira• � = Deasis Heoth, Architect d I � � �Y / I `� :1 _ it •I .� I 24]0 Yarioer Squore loop I1 1 I V '.- I r f Alameda, CA 94501 � ���I � CHILD UNDERW. I !i.IIIHHr I � � z I I 1 OPE TO ���I • &_ 1 , I ? 29'-6 1/2" BEL�OV1l • i' o I f' OPEN TO I I � ��=, I °r° i �� I � BELOW ��v" € 12'-1' S'-8' 12'-0' 1. j AREA- N�'C' °� I �Iu "' "' I , Drillings and vritten material appearing herein constitute original 8'-2 1/2" 2' 10 1 2" 10'-1" — I i 9 p P 9 ��� Y I O� = and unpublished work of the Architect and Noy nut be duplicated, i I used ardisclosed rithout rritten cooseni of the Architect NO T T T ��'" �' T T T T r / i ►.`4►�4►��I►I. ►�1*Mil �•►1.4►�4 •J aciAta. _iv__ ________Ap_ �% I ®DH ARCHITECTS- 2010 kM11 1.,►:.4►M.•Ki4 I•=.►��4►.,,.4►,114►.4QAQC laill*M4 PIIIISIEIIIIIMI'— 2' .o. .. .u. ''-0 6'-0" D. V N - � ► _ No . Date Issue �'` CHILD I�VVDER1Ai. '1-10, 6'-0' . . .�, �' 4 • 05/28/10 100% SET 1 i !4 • � OPEN! �— o ivil :cca ± 05/28/10 VT PACKAGE 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET ..* Ili ,� •— �� r—, .. 111 = .�• ill �I I N � _III ll r 51 : ( • I �G. I 08/13/10 PERMIT/BID SET co I ill.111 0o c,, > A III! SN�Ot m . I.�II + as '��I I � � �LLJE+ACC, II1 , ,1 I.I. • , 0 Iii III 'N A I i 1 11 17 1..._:.,......•., at: ..._ A k A ,_ 1�'' 'Hill ir � ®s+,1'-9 1/4 ∎ ° _.1� Y _r �, I ao I _ li 1 1 • ri ;) Sat. tva, 11 I I I I ( :Cj: Q : ►:4►�4►�4►�4►M4►24►�4I►�4►:4 :=::L-1:1: — ►„,o► 4► ■■ 4► 4► 4►.4►�4►1i '1,11 ill r�i.®'� '!�Ml [IT le- _ __ _ - _ --. — \ 36 '' ”" ADJ�A+L'ENT A. 2'_6" 49'-2 1/2' TI:NeNIT-111I[: 1 2' ! fiThilM. 53'-3 1/2" Q 8'-6' 111111EZEM 8'-6" EQ AI A9,2a \ - Project No. 44122 Scale AS NOTED DrawnBy: DM/AN E 0 C O C, R:\HM\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220_A20d.d N Drawing No. 0 (E) DIMENSION PLAN N MEZZANINE LEVEL 3,Q - MEZZANINE LEVEL v8 =t a' 4 CONSTRUCTION NOTES - 1 DIMENSION PLAN _ - A2 .Od Fil G• .C. TO INSTALL 10 GA STAINLESS STEEL CORNER GUARDS, TYP. AT PROCESSING AND BOH HALLWAY, SEE 10/A6.2 13 AUDIO RACK. SEE ELECTRICAL DRAWINGS FT G.C. TO INSTALL FRP WAINSCOT PANELS AT HALLWAY TO 4'-O A.F.F. SEE 7/A6.2 AND FINISH PLAN FOR LOCATION 14 ELECTRICAL EQUIPMENT. SEE 'E" SHEETS Fr HI / LOW DRINKING FOUNTAIN. SEE 3/A6.3 AND PLUMBING SHEETS H AS-BUILT PLAN TUBE HOLDER, SURFACE MOUNTED. SEE 1/A7.1. COORDINATE ANAL LOCATION WITH H&M. FT M• OP SINK. SEE 6/A8.0 AND PLUMBING SHEETS 1761 A• NCHOR STUDS TO WALL; DO NOT ANCHOR BOTTOM RUNNER TO FLOOR Fr SURFACE MOUNTED STANDARDS WITH SHELVES AT 2'-O O.C. COORDINATE WITH H&M IN FIELD. REFER TO WALL F17 BULLETIN BOARD. G.C. TO COORDINATE FINAL LOCATION WITH H&M P.M. illi&M TYPES FOR ADDMONAL INFORMATION. Fil SAFE. VERIFY EXACT LOCATION WITH H&M [7,] COAT RACK. G.C. TO COORDINATE FINAL LOCATION WITH H&M P.M. IT EMPLOYEE LOCKERS, SEE 3/A8.0, 12 TRIPLE TIER LOCKERS, U.O.N. Fi-- E• MPLOYEE TABLE AND CHAIRS IT REFRIGERATOR. GENERAL ELECTRIC MODEL f GSH25JSXSS Iiii S• INK AT LOUNGE AREA. SEE MEP DRAWINGS g MICROWAVE. GENERAL ELECTRIC MODEL f PEB2060SMSS FiTi INSTALL WATER RESISTANT GYP. BD. AT TOILET ROOM WALLS, TYP. INSTALL WATERPROOF MEMBRANE UP TO 6 A.F.F. ON TOILET ROOM WALL PRIOR TO FINISH INSTALLATION. I- 1 REAR SERVICE DOOR BUZZER MOUNTED 3'-6" A.F.F. SEE POWER PLAN. iiii (E) K-BRACE TO REMAIN EXPOSED US220 Fri] a RACK. SEE ELECTRICAL DRAWINGS. F (E) SHAFT TO BE FURRED OUT WASHINGTON SQUARE F24:1 PORTABLE FIRE EXTINGUISHER. MAXIMUM TRAVEL DISTANCE FROM ANY PART OF THE STORE TO THE FE. CAN'T 9585 S.W. WASHINGTON SQUARE 171 T B• LIND DOOR. SEE 10/A7.1 EXCEED 75'. ANAL LOCATION TO BE APPROVED BY ARE MARSHALL SUrTE H08 CONSTRUCTION KEYNOTES 1/411:111-011 9 NOT USED - _ I 3 PORTLAND, OR 97223 "- I CLASS: RED 2'-1 1/21 24!-0" 9'-2 1/2" NOTE: 7/ /- /-- FOR PARTITION LEGEND NOTE: REFER TO A2.00 FOR CEILING LEGEND REFER TO A3.00 moulamommom■mon H ---14 HANG HANGIIIHANG HANG A C C A C C A C C ACC ACC 1 . (E) DUCT ----AD (E) DUCT a I tl ii 23 III 1 Lu I \ : < TYP. < PROCESSING AREA :__ _. • 1 11.10 7:7 = : 1 ,100 SQ.FT. I _ _ Ale Z1 1 _ I I I I I co co 1 1 ' i I rn (fl = ,___ PROCESSING AREA 111 I 0 1 VB-1 • 1111 '1 Al I I PT-2 I t 1.0.N. 431 - _ ----- 9.-6" 1 /111111111:111 10 ,ra..,1 • ' 14' EAT,H,,.;-, Ilf * ir•-.), <I- > > 11. ACT-1 .... ..) Lu io 1 1 c., 1 , (---, * A LAM FDA CA >o< (P."' in Ell■ rwi DECO AREA _1 .._ 1 41 _ _ _,_ - - /1111111kb■- :::::<:::::: ■A11111 1 1741 .-,-, - 1 0 1 Q.FT. , 1 › › 03 EU (:::0 CT, 1 I C OF O ',:'-' VCT-1 I rn In rn rn ,_ ,_ F-61 DECO AREA • 7-EQ. EQ V8-1 _ I 9'-6 A/ // i PT-2 U.0.N. I I r w C-)r w 1 4/ Fr > , , > ,__, , ACT-1 I 1 1 >< 1 = bF.PF- 1 1 I 1 EQ. a p EQ. LI _ 1 HARDWARE 1 ' • 8'-4" 1 5'-0* 11'-3 1/2! 11$-11 1/2* ---/ La /--- 1 12 SQ.FT. / I • PROCESSING AREA HARDWARE • Dennis Heath, Architect IT VCT-1 r 1.11111111111111 I 011 . , 1 I 81-0" 2410 Mariner Square hoop VE1-1 I MENIMMEINIMINONINUMMI 8'-11 1/2* i ACT-1 Alameda, CA 94501 .4- 111111111111._ PT-2 U.0.N. 1 _ I Ill liCT2--) :II ilialo III III lanste ACT-1 "1 I .1 11- IN 1 i a oh 1 I ac., la 2 co tr) I LAN ROOM • 1 LAN ROOM En 1 1 . in '6.1b 41 S Q.Ff. 1 7 _ 9'-0" 1- Mr TYP. 1 ••■.I........•■■•.•m•■•= 1 lo am§ R A C<AM I' Itit.ill _ . , , 1 .r.,,.„ and !HUH material appearing herein constitute original ausidedunoPrudhiliscshlaellsevi"alipthi VCT-1 ACT-1 at uh te Avrrcihtittee:tconsent ond my of t bt:ed u:rl ie ch ai It ee de it VB-1 c? . 9 ir cir 1 a ------ ---- @OH ARCHITECTS- 2010 PT-2 U.O.N. afoul ) 1 H Lai Lai I I WEI .131131 I 111111 pp_9 ] I ELECTRICAL ROOM 150 SQ.Fr. \ }- - ii '. \ EQ. EQ. /- _,./ EQ. _ , , - ,-- I 1 QAQC JANITOR'S CLOSET 1 1 a.* 11111 VCT-1 JANITOR'S CLOSET IVA • 1 No Dote Issue 28 SQ.FT. • or i 1 ELECTRICAL ROOM 05/28/10 100% SET Lai Iiii VB-1 II u. gir',„Ei u qP 7.-9 1721* 10*-0* 05/28/10 VT PACKAGE tii- 1 GYP-1 1 : . 1 (1 A8.0 F1-2 U.O.N. 1 I I , 07/02/10 100% COMPLETE SET ADMIN ROOM . / I 11 MOM Ali yr \ MN -41111111111■ LANDLORD SET / 141 SQ.FT. ME\\ EI / - isms masa, - ■ 1 07/28/10 , ADMIN ROOM • , 08/13/10 PERMIT/BID SET I , ( El A, Alak I VCT-1 , E 9 6 II I 7 1 i I B'-6 GYP-1 • 410 410 ; N. EQ. EQ. / EQ. / V8-1 I 1... L.J 1-1 / EQ• PT-2 U.0.N. . _. t_ i_ i 1 1 Luck 1 IIIIIII 8 -..4 \ 1 El \ \ - \ • I I MEN'S TOILET ROOM EQ. 6'-O EQ. ><I1 • l■ . 1 SECURITY ROOM 1 7/ N I (-3-8 71 SQ.FT. , Ak I / \ \ 1 Ell 1 Cat I 1 , Lai MEN'S TOILET ROOM 121 SQ.FT. , \ b.._ \ MEETING/ _ vcr-1 < if PT-9 '1 aca TYP. \ \ D / el CT-1 I SECURITY ROOM • V/ a , L.1 19P-On - m \N 1 lir VE1-1 1 \ \ 9 -0" \ 1 PT-2 U.O.N. \ \ // , - 4-- _- GYP-1 IALI 1 I \ I V / NN dr 1 IGYP-1 1 < 1 F1' II / ,..... .0 WOMEN'S TOILET ROOM LLI 1 i ! / D lwil EQ. EQ. 10 .. CII 71 SQ.FT. 1 . I ( \ 1 I . . -N. ci / [ • II cv 41 1S-4 1/2* 1-.; ..t3 5'-0* \ zi_,-, El iw18" . 1 I . i CT-1 w9a_moesrs TOILET ROOM dr\ 1 10 III 41 -c. . V PT-2 \ LOUNGE AREA -1 • I II f 7 ( ) 1 fin GYP-1 1 - * LOUNGE AREA Lu) 162 SQ.FT. [11 AI 28 1 6 , A„. I 19 LI I I I 'I I 11 r= 38 i A8.0 111 111 0 dr A6.2 1 1 9'-0" VCT-1 w 1 I I Ei Iii I ---I 20 -r--i IT 9 ill 11 V ._ )(F-I" VB-1 111[1 k !I ACT 1 II Project No. 44122 I Iki 1. 1 --1-1.--'- 1 FC 1 \ PT-2 U.0.N. I lli 1-91 a iT- d - II III Ei II E I ri I PT-9 1 [PArl, A i 1 illi Li., .. , , i , , E6. DrawnBy: AS NOTED 1 8 , i pi_,9 .., y19 7 1 1.1. ■ ii 1 ., • DM/AN PP , MI , . - , • . cir 1 Lu 1 1 --- ONO ONIN,1•1111■111■4•1110 41111■111.■ORM MEN 1 . Fl 1=11 11E1111 1111'2 il• 430 ) 3'-11 se V.I.F I -- -- I H ME .-, R:\FRAProjects\2010_Projects\44122 Washington Sq\Drawings\CD\US220_A21a.d . 18. MIN. SALES AREA 37'-3* L MALL SALES AA ‘p. 10 CORRIDOR Drawing No. 0 BACK OF HOUSE I EINIWAY. MALL CORRIDOR I (I) HALLWAY HALLWAY ENLARGED PLAN ,... 261 SQ.FT. 1\/ (1) _ . '-o" 8'-0" 1. A SECOND LEVEL ACT-1 ACT-1 _. .-0,7 '=1' ,„_ - 1 I 1/401 1/4•14-0.CONSTRUCTION PLAN - BACK OF HOUSE (SECOND LEVEL) 7 REFLECTED CEILING PLAN - BACK OF HOUSE (SECOND LEVEL) 1 _.., A 2.1 a FOR PARTITION NOTES: LEGEND SEE A21a GC TO USE 6" 5/8" THICK FRT PLYWOOD STRIPS AS REQUIRED TO SECURE FIXTURES 9'-10" 9'-10"AL _--- B.O. GYP. B.O. GYP. IIF BD, CLNG BD. CLNG - '----, T.O. FITTING WALL MOUNTED T.O. FITTING T.O. FITTING �. - � ROOM WALL MIRROR TO COVER \ ROOM WALL ROOM WALL CLOTHING WIDTH OF FITTING , "< PAINTED GYP. BD. RACK W/ ROOM FROM T.O. / ADJACENT TENANT RODS 1'-1 12" 4'-10 1/2" BASE TO 81-0" A.F.F. US220 N.LC, __�' GRAB BAR / • PAINTED GYP, BD. BACK MIRROR, II _ ° / < DOOR AS PROVIDE BLOCKING • • DOOR STOP WASHINGTON SQUARE PAINTED • a I \ PAINTED GYP. BD. \ SCHEDULED GYP. BD. o 9585 S.W. WASHINGTON SQUARE/ _ ^ BENCH ---11±F---- _ 38 \� WB-1 LI SUITE H08 �, � � � � �; � WOOD BASE I i®ill AEI I InI I I®I 11®1 11®i 11 - -n n n n n � � i * „ � WOOD BASE o zs • — _ N „r \ ` N WOOD BASE I _r N �, / o' o" \ � _ 0'_oN ::=<: f 0 o ,�—■ 0 0 PORTLAND, OR 97223 I - —" ISHED FLOOR" FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR CLASS: RED . ELEVATION 0 ELEVATION 0 ELEVATION 0 ELEVATION (N) ELEVATOR 1 '` . 1 n L JJ�L • - \ `l 11� irrI':Im hil m11111,1u�1i 1'""Jlo I 1 IINNI 1 mu i 9'-10" 9'-10" �--i = B.O. GYP.\ S.S. J-MOLD TOP 1 3 6. AND BOTTOM T.O. FITTING — \ / c ,A BD. CLNG 8,-0" ROOM WALL • N a c 8'-1" / 8-6 'h�L7 \ \ T.O. FITTING 8'-O" / EQ. EQ. B.O. GYP.$ I , t `�' MACHINE / \ / ROOM WALL BD. CLNG „'`, ,;µ 1 1 N PAINTED GYP. BD, EQ. EQ. , 1 ; Raal1 �' �' 111, ��''. WALL MOUNTED MIRROR PAINTED GYP. BD, �; \ ./:.t.4, // ..----a TO COVER WIDTH OF \ �• �' ET GRAB c I ' WALL MOUNTED / = r FITTING ROOM FROM T.O. CLOTHING RACK ,. .. ��� BENCH TO BE FLOOR oo BASE TO 8'-0' A.F.F. • W/ RODS " , 16 MIRROR LIGHT BOX �L ��Y r---Z7 /_ _ _ SUPPORTED AND ∎ t , c, FASTENED TO WALL BENCH BENCH --;:sQ:Li /A €, i O 1 1 �-- AO N / " WOOD BASE N WOOD BASE 0-0 \ -- 0 -0 ti 0-0 �__I 01-0 = FINISHED FLOOR FINISHED FLOOR �� FINISHED FLOOR FINISHED FLOOR IN MEM 4:- .. n _ _ N ELEVATION 0 ELEVATION ELEVATION 0 ELEVATION N ■ 7(14) M v • OD / a... REFER TO © . L. WALL DETAILS /CP ri.� _ _ C N „, r CP / , d- � I - Dennis Heath, Architect iii =NI i1 ” " - 2410 Mariner Square loop Alameda, CA 94501 % ; l- -3 - HANDICAP FITTING ROOM ELEVATIONS 4 STANDARD FITTING ROOM ELEVATIONS 2 r 1 3s_8" I / / NOTES '4 N....> CO Nemo r _ -ALL FITTING ROOMS TO HAVE INSTALLED AN IVES PWS40.CVX (OR EQUAL) WALL-MOUNTED DOOR STOP TO BE PLACED AT ALL FITTING ROOM FORS, Drawings e e d written n o t e r i a l appearing herein constitute e r i g i n a l '�' �} �'T —i'i -ALL FITTING ROOM DOOR HARDWARE BY H&M SCHEDULE F-10 626 ELA PASSAGE LATCH and repurlishnd cork ni the architect end net eat be duplicated, - G.C. TO PROVIDE CORNER GUARDS. PROVIDE A MINIMUM OF 25 OF EACH COLOR; 4118 NH "SNOWFLAKE' 11015. GC TO USE PLASTIC CLEAR U sed a r d i s c I o s e d r i t Ti atoll t r r i I t e n c onsent o f the A r c h i t e c t c DH ARCHITECTS - 2010 i - w CORNER GUARDS WHERE WALL IS BLACK AND WHITE, TYP. O a I hUING / I PURCHASE FROM: AIMEE WALFORD- WALLPROTEX, 3750 OHIO AVE, ST. CHARLES, IL 60174 ..:1:. I Roo awn► I I PHONE: 630.333.9522 OR 630.443.4446 EX. 522 QAQC .\ 0 No . Date Issue CV I WALL MOUNTED I 1 W\ BO* _ DOOR STOP 05/28/10 100% SET , TM. 05/28/10 VT PACKAGE ,y� � ■ g41-3" 7'-8 1/2" BLIND DOOR FOR 07/02/10 100% COMPLETE SET / // `� ACCESS TO WALL BOX CLOTHING RACK - ROTATING BACK EE WITH RODS B MIRROR INSTALLED 07/28/10 LANDLORD SET = CC PER GUIDELINES 0 1 SERVICE 1 6 08/13/10 PERMIT/BID SET ° –I AREA SALES AREA = C A CORNER GUARDS, TYP. AT ALL BENCH • � WALL MOUNTED I CORNERS rli$ MIRROR LIGHT BOX J I ,; .4- / / d IG -.. ,4-1 . r 1 ! . 1 . ..3 . pn 14 ADA SIGN o FITTING 0j 4'-3" �� ' ROOM i '�- ts N N ,,,,=. — ......r...7•. ...p SALES AREA �• OPEN BELOW s C UNIVERSAL ,I STANDARD FITTING ROOM PLAN ACCESSIBILITY -� �� ! SIGN. SEE 7/A0.3 i r____, .� j —CLOTHING RACK I — \ e e ,o j WITH RODS N HIITTINGj \ `'=/ I I 11 1 \ ROM r 1 I I I i �' —C— BOXWALL \ r , -- 6'-0" '7 r—', 0 . 1 \ I i I FITTING I I ROOM 11 WALL MOUNTED MIRROR /i \ fALL OOR STOP�D ,--- !! ROTATING BACK MIRROR CORNER TO CORNER, iii-i-l! to ∎ d INSTALLED PER ( FURNISHED / INSTALL — „— - - -- �� c �� GUIDELINES BY G.C. .�Qj X 48 CLEAR "in 0 / I \ A / Project No. 44122 1 01 j CURTAIN N 7BENCH, REQUIRED TO Y ( 1 � (1--B. 2 ! i BE SECURED II I I 0!1 in �' Scale AS NOTED 12'-8 1/4" `�-/ -!� — \ o�,\ B i C WALL MOUNTED MIRROR ADJACENT TENANT 1 C3 ? CORNER T O CORNER D r a w n B y: DM/AN N.LC. N N E f[ , R:\HM\Projects\2010_Projects\44122 Washington Sq\Drowings\CD\US220_A21 b.c E I - N — . -- - _______________ .* L. ,. 4'_0" No., / Droning No EB U.O.N 12'-8 1/4" GRAB BAR FITTING ROOMS ENLARGED PLANS ''-`'' HANDICAP FITTING ROOM PLAN A KEYPLAN t,„,.., FITTING ROOM PLAN - FIRST LEVEL 1/4•=fo� FITTING - 1/ �=for 1 ' f-o� 1 _ 5 ROOM PLAN MEZZANINE LEVEL _ 3 FITTING ROOM ENLARGED CABIN PLANS, TYP. _ Aalb 1. G.C. TO PROVIDE CONTROL SAMPLES OF ALL FINISH MATERIALS FOR ARCHITECTS REVIEW AND APPROVAL PRIOR TO INSTALLATION. 2. G.C. TO PROVIDE SAMPLE AREAS (5'X5' MIN.) OF ALL SELECTED PAINT COLORS FOR CLIENT APPROVAL PRIOR TO COMMENCING PAINTING. 3. PROVIDE OWNER W/ 5 YARDS ATTIC STOCK OF EACH WALL FABRIC, CARPET, VCT, EACH STONE TYPE. 4. G.C. TO PROVIDE 1 GALLON OF EACH PAINT COLOR FOR OWNER'S MAINTENANCE. 5. G.C. TO PROVIDE ALL REQUIRED PAINT TOUCH UPS AFTER ANAL MILLWORK AND FURNITURE DELIVERY. 6. ALL EXISTING FLOOR TO BE PATCHED AND CLEAN, TYP, PARTICULAR CARE SHOULD BE TAKEN WHERE WALLS AND CASHPOINTS HAVE BEEN REMOVED. 7. THIS PLAN IS FOR INFORMATION ONLY. ALL FIXTURES WILL BE SUPPLIED BY H&M AND INSTALLED BY G.C. 8. G.C. IS RESPONSIBLE FOR COORDINATING, RECEIVING AND UNLOADING ALL H&M SUPPLIED FIXTURES. 9. G.C. IS RESPONSIBLE FOR DISPOSAL OF ALL ASSOCIATED CRATING AND REFUSE FROM H&M FIXTURES. 10. ALL FIXTURE LAYOUTS TO ALLOW FOR 3'-0" CLEARANCES BETWEEN FIXTURES. U S 2 2 0 11. G.C. TO INSTALL WARDROBE FIXTURES PRIOR TO WALL GYP. BD. INSTALLATION. WASHINGTON S Q LIAR E 12. G.C. TO REFER TO H&M INTERIOR CATALOGUE AND INTERIOR INSTRUCTIONS FOR FIXTURE INSTALLATION. 13. REFER TO FINISH SCHEDULE A0.3 FOR MANUFACTURER INFORMATION. 9585 S.W. WASHINGTON SQUARE 14. COLUMNS TO MATCH WALL COLOR IN ROOM. SUITE H08 15. ALL WALLS NOT MARKED ON LAYOUT TO BE PAINTED PT-2 PORTLAND, OR 97223 FINISH PLAN NOTES - CLASS: RED CD41) D D 40.1 BB.9 BB.1 B B AA.1 GI 11111 TAAMBt�l. 066CF�'710N PT-1 PAINT - "CHANTILLY LACE" I GLOSS: FLAT PT-2 PAINT - "CHANTILLY LACE" I GLOSS: EGGSHELL PT-3 PAINT - "IRON MOUNTAIN" I GLOSS: FLAT I I I I I I Madan MEM PT-4 PAINT - "IGUANA GREEN" I GLOSS: EGGSHELL SN ES AREA ray FS aaIe FLOOR: CST-1 FLOOR: _1 PT-5 PAINT - "BLACK" I GLOSS: FLAT \.1 1 . ' `.if WB-1 I I BASE. :.i 1 - " ". WALL• PT-6 PAINT - BLACK I GLOSS: EGGSHELL tei LAREA PT-2 WALL 2 en ELEVATOR FLOOR: CST_1 FLOOR: CST-1 BASE: - -� - - --- - - -I ®I- ± - -- -- 1 : 38.3 PT-7 PAINT - "AMHERST GRAY" GLOSS: EGGSHELL • ALAIVIEDA►.CA WB-1 � i � I � � �� BASE: ,,,,c.§.. SST WALL: PT_2 PT-8 PAINT - "WHALE GREY" I GLOSS: EGGSHELL NI SST WALL w I II I - I DIY. BLACK LAD. �Y LAD. - • :Y I WNDOW #1 PT-9 _ " PAINT "WHALE GREY I GLOSS. EGGSHELL I ' ; � FLOOR: MDF .. .111 - _ - II 1- t`' I I I I WALL PT-10 PT-10 PAINT - "DECORATIVE WHITE" GLOSS: HIGH GLOSS• ....1_::)3 11 B D LAD: DENIM o ( I I ! 37.9 PT 11 PAINT - ROCKPORT GREY - SABLE GASPESIEN" I GLOSS: EGGSHELL El ter' �� a 4 °-. • -- PANT d °> all'o .4 5 p 1 CON-1 CONCRETE - MATCH EXISTING MACHINE ROOM I I 41.63 TYP. -- :� °I[c-` I �T-1 Dennis Heath, Architect FLOORVCT 1 _ I °` �" I I CST-1 (E) FINISHES CPT-1 2410 Mariner Square Loop BASE: Illik, I- - ( } AREA RUG - PERSIAN WOOL VB 1 Al ameda CA 94h41 I 11A .- WALL: 1 B I6.111 PT 2 I LAD. Y COAAI�AC�y, CPT 2 AREA RUG - GREEN 6.2 DIV. RED I •. I I I OPEN ABOVE AREA- N1D` „11111 I I CT-1 CERAMIC TILE - GRAY e..r C - �- I ......... ......... ......... .......:. .... .---. --..:::-: ..-..-:- .-------- . .:.:.._ ...::..: . ...:.:... _. ......... . ....._ _.._. __.. _._.... Drillings and written notarial appearing herein constitute original . p . 11 II CST-1 and unpublished cork of the Architect and may not be duplicated, . A6.2 CERAMIC STONE TILE used or disclosed without written consent of the Architect . I iI LL 1111 _ ----OR--J �wr: -- -- a, �DH ARCHITECTS 2010 r . _ . A . • 'A - - -------iii) 0 al LLT-1 TILE - COORDINATE WITH LANDLORD OPERATIONS SUPERVISOR m 4, . 4 ., : 10- a ,,A(,,„ . I 4 . MDF . .° ° e d, 4- .� ...Q..: MDF BOARD - PAINTED PT-2 No . D a t e I s s u e EIMELEMOKAL al. , . . <: SS 1 0 /2 /10 ° ° - _ I _..:.,x.. I S 8 100% SET FLOOR: CST-1 ' - �. I LAD. LQQ� VCT-1 VINYL COMPOSITE TILE - SHADOW BLUE I I I I � 05/28/10 VT PACKAGE BASE. WB_1 r 4. I I I �� 07/02/10 100 COMPLETE SET WALL .. - I I �! 0 1 I ,I Wes-• PT-2 -� I 1111: I LAD. M CLASS. I C / / LANDLORD SET WINDOW #2 WP-1 WAINSCOT o7 28 1 a I I FLOOR: -- 08/1 /10 FERMI /BID SET � DN./� + LiVVDER1At. CASHPOINTS LAD.ACC. MDF PERMIT /BID I I VII 1B I I I WALL MDF BASE - PAINTED WHITE FOR ALL WALL COLORS EXCEPT PT-6 ....i I I PT-10 WB-1 ON BLACK WALL TO BE PAINTED BLACK. SEE 5 A6.2 / � � wr 1 _---r______________ 1 6. 4 , I I LAD. I 1111, 8 S 8I I8 , CERAMIC TILE ARCTIC WHITE I Piiiirmiti ________ ___ 1 WALL COVERING I UNDERW. LAD. L.O.t� I Iill ' 111 IN NM ININE■MO , - hAl. T r ®, r ( 36.1 VB-1 VINYL BASE CADET BLUE. SEE 7/A6.2 ee ii, - -- -- -- - m! - -- -- -- - .', ,,I - - i i- -�-I - 3 6 SG-1 SPECIAL GRAPHICS WOMEN$ WOMENS S!��ES AREA SALES ARE STORQAE STAIB$ SPEcIAI.MOH= FLOOR: CST-1 .TENT FLOOR: CST_1 FLOOR: VCT FLOOR: CST-1 BASE: BASE: FINISH LEGEND - 2 WB-1 WB-1 BASE: SS-1 WALL: PT-2 WALL: PT-2 WALL: PT-2 Project No. 44122 Scale AS NOTED DrawnBy: DM/AN E a a NR:\HM\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220_422a.d T Q (1) NI- Lo .. Drawing No. 0 0 FINISH PLAN N FIRST LEVEL a 8"-� - 4 NO T USED i H PLAN - FIRST LEVEL _ _ A22a 1. G.C. TO PROVIDE CONTROL SAMPLES OF ALL FINISH MATERIALS FOR ARCHITECTS REVIEW AND APPROVAL PRIOR TO INSTALLATION. 2. G.C. TO PROVIDE SAMPLE AREAS (5'X5' MIN.) OF ALL SELECTED PAINT COLORS FOR CUENT APPROVAL PRIOR TO COMMENCING PAINTING. 3. PROVIDE OWNER W/ 5 YARDS ATTIC STOCK OF EACH WALL FABRIC, CARPET, VCT, EACH STONE TYPE. 4. G.C. TO PROVIDE 1 GALLON OF EACH PAINT COLOR FOR OWNER'S MAINTENANCE. 5. G.C. TO PROVIDE ALL REQUIRED PAINT TOUCH UPS AFTER FINAL MILLWORK AND FURNITURE DELIVERY. 6. ALL EXISTING FLOOR TO BE PATCHED AND CLEAN, TYP. PARTICULAR CARE SHOULD BE TAKEN WHERE WALLS AND CASHPOINTS HAVE BEEN REMOVED. 7. THIS PLAN IS FOR INFORMATION ONLY. ALL FIXTURES WILL BE SUPPLIED BY H&M AND INSTALLED BY G.C. 8. G.C. IS RESPONSIBLE FOR COORDINATING, RECEIVING AND UNLOADING ALL H&M SUPPLIED FIXTURES. 9. G.C. IS RESPONSIBLE FOR DISPOSAL OF ALL ASSOCIATED CRATING AND REFUSE FROM H&M FIXTURES. 10. ALL FIXTURE LAYOUTS TO ALLOW FOR 3'-0' CLEARANCES BETWEEN FIXTURES. U S 2 2 0 11. G.C. TO INSTALL WARDROBE FIXTURES PRIOR TO WALL GYP. BD. INSTALLATION. WASHINGTON SQUARE 12. G.C. TO REFER TO H&M INTERIOR CATALOGUE AND INTERIOR INSTRUCTIONS FOR FIXTURE INSTALLATION. 13. REFER TO FINISH SCHEDULE A0.3 FOR MANUFACTURER INFORMATION. 9585 S.W. WASHINGTON SQUARE 14. COLUMNS TO MATCH WALL COLOR IN ROOM. SUITE H08 15. ALL WALLS NOT MARKED ON LAYOUT TO BE PAINTED PT-2 PORTLAND, OR 97223 I I - CLASS: RED - 0 FINISH PLAN NOTES _ ID0 0 E E DD B B A A '" 1 SYMBOL DESCRIPTION -1 PAINT - 'CHANTILLY LACE' I GLOSS: FLAT 3 PT-2 PAINT - 'CHANTILLY LACE' I GLOSS: EGGSHELL PT-3 PAINT - 'IRON MOUNTAIN' I GLOSS: FLAT IT1 _ DENS PT-4 PAINT - 'IGUANA GREEN" I GLOSS: EGGSHELL SALES AREA SALES AREA — I FLOOR: �_1 FLOOR: �_1 PT-5 PAINT - 'BLACK' I GLOSS: FLAT }`� , r' I 1 I BASE: ;:.i 1 I I BASE: WB-1 I IKIDS /EALBLASEIA WAL : 2 WALL: pT_2 PT-6 PAINT - BLACK GLOSS; EGGSHELL 01 S FLOOR: H ELEVATE CST-1 — — — — — — — — — — — — — — ►--3 _ I ::PT.7 . ........................................_.................................................:aPAIN'f:::- AMHERST::GRAAY':a:::GLOSS EGGSHELL AU4MEDA, FLOOR: Cam_1 BASE: WB-1 ►�� ►�� ► BASE: SST WALL• - - PT-2 8.... PAINT - 'WHALE GREY'...I GLOSS EGGSHELL I WALL: 4.:S 1U SST , , -2 PT-9 PAINT - 'WHALE GREY GLOSS: EGGSHELL EMI NM = ME ME II= I'.... 38 0 6 ... I 0/1111 ►`�r_�► ►�ii►� —��''�''�E �� i► ► �► :► i►,i►�•r :r.° PT-10 - 'DECORATNE WHITE" ( GLOSS: HIGH GLOSS ,'am NE ss� MENS LAA,Gt I s 1 OD e d e e' 1 " MENS I H&M I •• I•* •e ' '�'".._ . BEYOND PT-11 - ' - EGGSHELL I 'r u, 11B •i �' 4 PAINT ROCKPORT GREY SABLE GASPESIEN GLOSS. E• 6.2 • SG-1 �Y d. `p ..ra iiiE —.7 IIIII =I � \ e'}! e •° - + PAINT FUMES � 4 �.� � � I I � CON-1 CONCRETE - MATCH DUSTING Dli 0 f ,, , s Dennis Heath, Architect STAIRS WY 2410 Mariner Square loop CPT-1 CST--1 ► • c c AREA RUG - PERSIAN WOOL :::: Alam 94501 11A — � Alameda, CA a BASE. I SS-11 As.2 _ A,..� a hUMI. CPT-2 AREA RUG GREEN OMER TO WALL I ' PT-2 I I � t MEN3 _ I jia iiiiiiim CHILD U�VIRW. BET. � _ ± @4Y I CT-1 _ QEdl�. `: MAX N CERAMIC TILE GRAY Orawin s and written material appearing herein constitute original t> 9 PP 9 ri.. on @QY — ; and unpublished work of the Architect and may not be duplicated, l �l •e • • 44 .. I �0 CST-1 CERAMIC STONE TILE use or disclosed without written consent of the Architect 4 A�i —1 ®DH ARCHITECTS- 2010 _ _ _ _ — LLT-1 TILE - COORDINATE WITH LANDLORD OPERATIONS SUPERVISOR - � 4 _ — — • . • = ./: BASE; -1 QAQC • , • , .11.....m.1: .. .—. BUJE+AGC WALL �_2•1 iii MDF MDF BOARD — PAINTED PT-2 d • No . Dote Issue d A e e. d a CHILD t�VDERW. a e,: _- .. ..,,.,.. 05/28/10 1007 SET VCT-1 VINYL COMPOSITE TILE - SHADOW BLUE 05 28 10 VT PACKAGE 111 ---- R.R�OR COVERING 07/02/10 100% COMPLETE SET II' ` 07/28/10 LANDLORD SET . i ( WP-1 WAINSCOT 111 � � I, I I' �. 08/13/10 PERMIT/BID SET 111 `i c 10 ., UNDERW _:.1;r•.kit: � C !N pLUE+ADC MDF BASE - PAINTED WHITE FOR ALL WALL COLORS EXCEPT I ±B�. I ± I► WB_1 ON BLACK WALL TO BE PAINTED BLACK. SEE 5/A6.2 II 4 7::::).------ I �, , - 'I 1PT6 WI-1 CERAMIC TILE - ARCTIC WHITE / / ll E _ _ I _ _ 1 _ _ l , _ I _ H- , -• 8 $I [ 1$ SG-1 1-. I VB-1 1 VINYL BASE CADET BLUE, SEE 7/A6.2 1 ` --- I WALL COVERING ►��I►��►��►��1►��►��II►=1►��►�� �' �' ssss�ssi ►��1►��►��1►�4► '�►��►��►��►�� ����E' '!� r�Mil 0 . ._ _--__-__ ....�_ _ _ 401-------_, .- - --------4,----_--__ — 36 SG-1 SPECIAL GRAPHICS KIDS / BABY MENS SALES AREA SALES AREA STIR SPECIAL FINISHES .� FLOOR. FLOOR: _1 TENANT-N -1 FLOOR: 1 1 - BASE: �: E; FINISH LEGEND 2 WB-1 WB-1 SS-1 WALL PT-2 WALL: PT-2 WALL PT-2 Project No. 44122 Scale AS NOTED DrawnBy: DM/AN E 0 0 d e N R J1 :\HM\Projects\2010_Projects\44122 Washington Sq\drawings\CD\US22022b.d E ED Lil �■ Drawing No. O 0 FINISH PLAN N y MEZZANINE LEVEL p, FINISH PLAN - MEZZANINE LEVEL �a'-�-O' NOT USED - 1_ 4 - A2 .2b ._ WEST IPS: "LAYOUT' DATED: 05/12/2010 111!i/11111F11111// 11/11! nUGHTING" DATED: 05/07/2010 "DISPLAY" DATED: 04/23/2010 US220 WASHINGTON SQUARE 9585 S.W. WASHINGTON SQUARE SUITE H08 PORTLAND, OR 97223 CLASS: RED * (1..A-@) BB.9 BB.1 BB AA.1 A A Z.1 0 1 1 Magi MEM SALES AREA SALES AREA r N *. I ' •Vkl‘'il 11 A \ a, , • - H ',- ALAMEDA. CAcs7, ADAKENI I I I *If MIMS_ Mitialia. _ :.....). SALES AREA • ELEVATOR a_ 1 __ __ , __ __ .. __ 38.3 IIIIIIIIII 011111111111 11120: I NM I-1—[ • .77 C1A1OUG C1121 C11209UG C11209UG C1121000 C11209UG C11211C1120SUG 2 1 20qaC 1 ! C11 'UG 2, C11209Ja C11209UG C11210UCI C11209U0, 2 C11209UC1 Li,AtIt. 1 4 . In UG UG - I .N, 8 cs 2' _ 14 1 E . 1 , _ ' 1 1 L-7);dit. rt,„...a,- ---- . ' (- ri— +_ 1 .1 -TIV Iii ,-,, , , 1yp.1 C11126XZ I JVAlill I C11126XZ I ,-,MMM =‘ , •-■........■ DISPLAY ; 1263 0 R Lc--,' Q112.3 L.6211.6iimami7,11----1 , _ A . 4.4:iiiik. WINDOW 01 c5 0 _, n I 4!11 -...... _ _ .:r _ ___ __—__—_ ___ _ 1 = — — „-1,- rn-11 Lcr,,'_ -:1 EF,_ -R:. E■I 111 I .L,_ 38- ... -, ,...0 •lan BM = I 1 1111 _________ .._.____ _____ _1 Ili - (j; c, iii ,--. ,i3 1 1- .■.......... A.Amm■ ....... C '---l_D ■■■... mmilimm X) ....■•• . C1121OUG C11209UG C11209UG C11209UG 1124„RCC1121DUG C11209UG C1120%1G C11209UG — 1.=... no OM :1) 11E7= ,-, ,-, 6TO ZELL 1 I - - - .-, I , - _.7,. ,73---- ,--<,-s- +4- . 0 1 1/J 3 E 1 1 .k, /1.4 k_I k/ N., = 8 <=, x ,.. x 0, I .g -- . ,u cp = 0, x x x x 37.9 II - -71,-4 , - , _- ;7_ - - - . . = N, 1,,, t(-L' N , • m i - 7,- I L_, m . I — ii.... ri;;Alftra x 2679 2679 1,1 x =Emma= I 11 1 - i_._. Al 0 SL ill °It 17 K1 * BW BW if, c-,, - .............. - - 08 C 11 IRC —...1I '- 14 14 MISMEILBQQM 1 • — 0E91,1 i r'n"s 1 WP. D2 e4 n7 no i:aHrei an tehr,sArchitect p E., 7X9Z41,7 I 7 - — ,;',11203 XT 1 Tc, IC 11.11 441‘ i.._,A y1A2*-1----- I LD I ZX9ZH,LD 1 I Z 9Z1,1,1,D I .■--------1' ..-----____ a3r---) - --:.-; 7 MALL I — ,,,, ,,,I,- - x _ ,,- 1 ?63Q N MAE& Alameda, CA 94501 I I L--) ___—_,----.0 ... ,0 N 11111111111 E hi ,,,,. A, _ ABE6.2_wg. Nits.s"6"' i . .., ., , I . l_D I.......■ t _ MUM - 2__----t-.. , 2 I i. _]:=1., r .rs .- ,,air ,, ,, 411..' --7 ' , ,,,,, \,, <„ iii, , - 1 ZX9Z41,9 a I Z9Z1,14] .14 .". ..,,. Mr 1.811. e , (...., .....•■■•■•■■ Ii I................_k I . _ L., DI)SELL1 DC160Z1,0 Dr6,0L1,1 D 01,Z4D 11202 Q3' ,i4111101tt Q It FIF 1:81(11211625‘I1uIlIII ..., 1-,-. 7-i-,; -- T A 11291Q ,\_, 4 „.. ,,\11)'\ 'l..N ". .A i kit -. II 4, ,---- 77 0_9 .5',.-> Q„) 44441*9 2 9 N .—-------—E 111 I B Y. Orilli193 o i il vritten material appearing herein constitute originol and unpublished wort of the Architect and may not be duplicated, used or disclosed without written consent of the Architect D IMI I I - ■ I _ ___. o-, ®DH ARCHITECTS-2010 — GI r., ... i r:i ; Q11263 11263Q Eli 203 XT (--1- ha i UM IR i i -NE I 11 C1121OUG C11209UG C11211C1120SUG C11209UG UG 1120it`C Ess.)± Go,,, '2',; 111 . 1 263Q m El _ 14 112910 ....... QAQC No . Date Issue anN11112216. NV 711111IIM I 1 I I.._.- rTh IALINDIaa 6ED ZOM I-_-:: 111 2r)-4— , -1 DHIV1.1, aiiiimmw • D27180 1.1, (9 ,-, N.,- ' 36.9 IDE9ZIL iv 0 05/28/10 100% SET 74 ,,,,,..,..7,,, I 2 I Ic-n237:1 r'111111111.11ri ..1::1: 1120 XT ++0, I h1111127AZ -1- 05/28/10 VT PACKAGE .91,--1- ',--,' >s<, X m h., X 1,1 II IP ! 5 i 1 (s, ,-1 I . _ 1 12630. it) RMEN FLOOR - 'cCI c5 -- -_-_..--- co," 0,' 07/02/10 100% COMPLETE SET ..x ,s-L-- 1 ,_72:4,_ ?_-‘, i■E--- E i 1 — , IL, ,7_,• • R A C K I "" co --il E57 — ____ ,-., --..----— - - „., 7.= ,-------c,.. --, --- 1 --- -0 A,ke OA _ill • ...:1-. 1YRF;- DISPLAY 07/28/10 LANDLORD SET ...- ri,,1 i I.040 r A Issj 1 1 9 Itr7rAz C11123XZ -......, ,:) iitiagila c) I,. 1,, 'g 08/13/10 PERMIT/BID SET c-, -:, 1;00.4 At: Inhallacts. cD L. x I 1?,-):Al& x ,f) 1 - .v4ir _ ii 7Ua k ____‘■ ...........u_. ,,,, _ _ ...... SD , gi ,---..-...,' Ng , , _ 2 w9 ,R9 BEI L7 wasuisi 14 I — i =7 i --:-) 1.1 , TYP. -IIII I. ---- x''' ,, — _ ---- ,-.., X ,,,, c., <-- ■■■■ -s mows r--1 1:7..i...: 1 : i ,-, C11123XZ c) I k E ,••••1 'aim • --( x PA -< Me x KR Iti2.71Z i---,1 - . : 10111111111111 .4m...... ,'....., D'21-71-- lik' c:-, _ L'1, DC160M3 Drboao DnoLm3me• _____ Dn6ami Dn6OZLO DnoLz43 ...... `. .-r-: ,, :8 ':--;'),At. c' I I L7a GO mai L.11119 7-- vAr , 1 T a MI , mica 1 MI 1 , 1 , ic-3 I ' _ 36.1 4 ' 1 41 MALL UNDERW. 14 Ligligna. i •V-- 111, All■ ,-, . C11171A29 - lYP. 1 MM. 6180Z ■,7)on Ir'son9Lur_. onamp 01-191,ZZ 1 . -i_ Dn6ono 116OULD Dr160Z1.1,1 DnoLz OD 91160Z1.0 D1160Z1,0 91160Z1,0 Dnot.no I I h... _____ rz.. .E.--■ 1_,..--............lir--„...— • 111 7 — Ill 1 , 1 36 __ _ _____ _ MM.- •111••••0-. 'MI.., 41.100 ...Mb 41■11----4111.- ----41■110 ■-.=./........... - 4111■-■■■■■■■■■■■■• I WOMBS Malan. SALES AREA SALES AREA BIOME STAIRS ADJACENT mai:a= NOT USED I _ _ 2 FT! WARDROBE FIXTURE SYSTEM. SEE SHEET A7.1 rfl ILLUMINATED POP—OUT WALL PANEL FIXTIJRE SYS1EM. SEE DETAIL 6/A7.1 AND MEP-DRAWINGS FOR PANEL UGHTING. Fri B• OX WALL — ACCESS FROM BACK pl. FREE—STANDING WALL-ROME SYSTEM, 1YP. SEE INTERIM INSTRUCTIONS. - P r o j e c t No. 44122 Ell FLOOR CABINET FixruRE SYSTEM. F61 W• ALK IN CLOSET FIXTURE ASSEMBLY. Scale AS NOTED 12_ FLOOR UNIT FIXTURE. REFER TO FIXTURE PLAN FOR LWATION. DrawnBy: DM/AN 1--, B• OOK SHELF FIXTURE. REFER TO FIXTURE PLAN fOR LOCATION. F-9-1 BAR SYSTEM Npi.., PILLAR COMBINATION SYSTEM R:\FIPAProjects\2010_Projects\44122 Washington Sq\Drawings\CD\US220_A23a.d g.. ii ED -FRONT ARMS & HAT DISPIAY SYSTEM ,,- in •• Drawing No. ..._ 0 12 BOW WALL SYSTEM E; FIXTURE PLAN N NI- Fsi WAU. BREAK SYSTEM FIRST LEVEL a, H MIRROR. AT PORTAL SEE DETAIL 5/A6.5; AT WALLBREAK 6/A6.5, AT COLUMN SEE 4/A6.5 , a LE 1/84-0" .. t, FIXTURE PLAN - FIRST LEVEL 4 FIXTURE PLAN KEYNOTES 1 . ..,-, _ . A23a ,__ LATEST IP "LAYOUT" "DISPLAY" DATED: 05/07/2010 0= I- ACC ACC --6303 US220 ), - a CE303E51 W WASHINGTON SQUARE _ _ 47 9 L L L D I 9585 S.W. WASHINGTON SQUARE \70E91 - 59660 SUITE H08 591.10 PORTLAND, OR 97223 \'70E9J m 5911.0 CLASS: RED 110 DD (ill) BB AA :10 0 , CI8 s 6303 I 6303 947E9 _ I ►A , — 1 / 1 W 1 ' SALES AREA SALES AREA f A o I rt1 t*IA ' m rs 6069 � � V I j I �qDB / BABY, AD�IACENT 0, 4 IS HEATH rc's'i 6069 TE WEE NL ATI ei- j SALES AREA - AtAM1FC) . �A AL IOWA - "- �• C- . - 1 C- ,.,, -Q 1 C11227UQ C11227UQ�11122?UQ : 2069 I I I c I -4/4 --- P o E9z � I I Q.� 0� E I C1 ■ 8UQ C11227�JQ C11227UQ 112 :PE C11228UQ 011227]6 C11227UQ ;_ N 1 • • cs N ::, TYP. 1 2 6 3 Q m � �; c� I C11214XZ I iic CJ n_I 7 MI -1;'1-1frilli MI liiii il 1T��!1. 1 C fV N L-------- 38 -�• r�' rn��„7:177 Q ' u ♦•+ �-� + 212 5 Q o 0 0 0 0 0 o W D : 3 D D D BOY 3 D D A D D D D MENS Hd�M 11 E �, 1 I a v v BOT , -)7i -a -a -.� -� 2 DE9Z � �, i 3000 _♦ ,;£k 1—c- _ 9386 — --------------. 21171' .. I 2117ZA 14 2125 Cl lirj-Cl I C11214XZ 11 1:R C �,� TYP I �SSST IN_N to ha IN�� .. I C11214XZ I t�S 2117 Z A I t riai r� :ar, ri:�:� 212 5 Q SS _ ,1 14 �, • I Dennis Heath, Architect 63201 • . C3183A17 �i 26„ �� + + -} .}. N `� _ + N : ®dg 2470 Mariner Square loop p�y� MALL C3180A17 116ZA �J 51'76 116ZA 98E6 Q ROOM 3 a A a m e a, A 94501 `r. bE0513, 081. �` e •- m 2010 39 A — �� C11214XZ, `- C3180A17 + + .®� 00*► + ' ry - +o Y ,TO N r 3 - ■�. C3180A17 h �W + 11 m .. _�� r � � OPEN TO N1C.MEfili'�,, I 1 I 9384 F25 3000x2500 BELOW C3180A17 116ZA -I- -I- 1111.11:A. 1 6ZA + .®.. ` , CH,/I�„( _ I + I N Drawings oad erittee material appearing herein constitute original J 318017 a - Q a a c a y 9 PP 4 9 •,. ♦ w c°o a°o 2117ZA I- + + + - `ji rn m r:, r . �� r and unpublished tort of tie Architect and may t be duplicated, 3180KYI7 _� ♦ @QY Ai��M used or disclosed tithout written consent of the Architect v :° ,:i �' a • .I* I 2117ZA I N ►_. c�,_.a►_-;sr�.,:1 ►_.����,,.a►_.r_ar.�� ' .: ARCHITECTS- 2010 — — 2125 Q — (DOH .. ili — D111111111111111110 N, Peri:4W::410�.4rcvs� •► - �MSVA� tee■ •• - � s „ �� 4''>y � Q�� ►rrs��,rte :ar, w:rr'��' �� �1___ 1 �"� i ,`C 31�illh UNDEI*6 2 2 8 5 Q 9 LAa o w o o w _ + C11214XZ Issue A D D D D D D D D D al # Ate. I, › , p- _ trf: + + + LA LT LL C3180A17 m 26h + 5 m 05/28/10 100% SET 05/28/10 VT PACKAGE grA �` C3180A17 26,`` N N N 11147XZ 11147xz Eder L� t + � a 07/02/10 100% COMPLETE SET asamman __ j I -- 1 -F + 4- + 212 5 Q El ' I 2117ZA ILLd08LE) I �' l I 2000x3000 07/28/10 LANDLORD SET �05�%00' N �,' �I �" N 9386 NI t, LLd08LE) - N_ 08/13/10 PERMIT/BID SET '� 11147XZ ' I,I I n E9Z L — r' .�_-�i•L A J[ 11147XZ 2� I C11214XZ 4 LLd08LEJ . (�!� �� 7- 1.1 I I - + + o r1 Ii..Es, M -,t. BMA ... N 'I ,Ip� I�►�l 1 263Q — N + + N LLV08LEJ -. I ‘-r3 MI N ID MI �L�DEM I o �. E+Al t C3183A17 x , -< <me ' 1 ��, ' + x x INN= ±- W oncz: onczz��] nnczz�LD onczz��� on8zz,L �A� � � t + °m Q ` U�i±SH3XR ��� I -- �. , I I'I .- �i� 2 116ZA + Q 6 k7600+ N 2125 Q I o 80A 5 3, TYPJL:i p , r- r-- , r- r- r r r- 'I m •. I a c a a a a - a a a + o f 1�- a�c a a < a a a LLb4BLE3 2 N_ C 18042/ 0220 2 °m 0220 0o ao 2 2 ( ( - 2 2 2 2 2 2 2 °w 2 /1 rii I ' , ,m m m m m n m m m m m m m m m m m m u u u u u u u u u - u u_ :. u v u u u , ��I� `�.j aiEOZZ 2ilE0z �..: I nn6EUL3 lrOVI.1) — — -- Dn6CZl1,3 • r*7Z113 1 i∎ I►�1 i_2►;s*M4,1�1le::1 W Iiii ► II► 4111►�4►.oI►--z►��►��Ir�:1►141 i ®mu �®�.. �. -_ - - .. - - - --- - - -- — .,_ - - 36 KIDS I BABY ADJAME MEM SALIELABEA. TENANT-NJ SALES AREA ST NOTUSED _ 2 I-il WARDROBE FIXTURE SYSTEM. SEE SHEET A7.1 [i-i ILLUMINATED POP-OUT WALL PANEL FIXTURE SYSTEM. SEE DETAIL 6/A7.1 AND MEP DRAWINGS FOR PANEL LIGHTING. 3 BOX WALL - ACCESS FROM BACK r :i FREE-STANDING WALL FIXTURE SYSTEM, TYP. SEE INTERIOR INSTRUCTIONS. ■- Project No. 44122 111 FLOOR CABINET FIXTURE SYSTEM. 17----WALKAN-CLOSET-FIXTUREASSEMBLY;------ S c a l e AS NOTED u.....FLOOR....JJNII....fLR .I..---REFER-,.TO...,FIXTURE..PI AN-FOR.,LOCATION, DrawnBy: DM/AN FI-BOOK-SHELFTIXTURE"TREFER-TO-FIXTUREPLAWFORAOCATION:- ::COCATION::::. BAR SYSTEM E.' N - (' ....PILLAR,..COMBINATION" R:\HM\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220J123b.d T Q . . ::.fRONT::.:ARMS=:.:&:::HAT:::DISP[AY":,-SYSIEM 11 Orating No. SOW-WALL-SYSTEtu---- 12 FIXTURE PLAN CV f13fWAaBRE4(.SYSTEM MEZZANINE LEVEL 1 Fi MIRROR. AT PORTAL SEE DETAIL 5/A6.5; AT WALLBREAK 6/A6.5, AT COLUMN SEE 4/A6.5 ut FIXTURE PLAN - MEZZANINE LEVEL US"-r-� 4 FIXTURE PLAN KEYNOTES i A2 .3 b . . , TM SYMBOL. DESCRIPTION LOCATION A O 8" RECESSED METAL HALIDE DOWNUGHT WITH BLACK TRIM SALES AREA PIA B El SQUARE SINGLE LAMP RECESSED METAL HALIDE DOWNUGHT WITH ENTRY / PORTAL / 7/4/11 BLACK TRIM ....... ...:...: ....... �` ......... . .. --FI111NG ROOCNS-_./ ALCOVE C 0 8" RECESSED METAL HALIDE DOWNUGHT ENTRY C WHITE TRIM FINISH E E BLACK METAL HALIDE TRACK HEAD SAS AREA MD MEDIUM SPREAD F ® BLACK METAL HALIDE TRACK HEAD SALES AREA F SPOT SPREAD G WHITE METAL HAUDE TRACK HEAD SALES AREA G SPOT SPREAD H 1111D BLACK METAL HALIDE TRACK HEAD SALES AREA H MEDIUM. SPREAD US220 J CO BLACK METAL HALIDE TRACK HEAD UNDERWEAR AREA J SPOT SPREAD WASHINGTON SQUARE K ® WHITE METAL HALIDE TRACK HEAD UNDERWEAR AREA 9585 S.W. WASHINGTON SQUARE K MEDIUM SPREAD L1 ILLUM. WALL PANEL SUITE H08 2 0 FLUORESCENT STRIP SEE E2.3o PORTLAND, OR 97223 L2 �? 3'-0" FLUORESCENT STRIP ILLUM. WALL PANEL CLASS: RED SEE E2.3a 4'-0" FLUORESCENT STRIP EE PANEL 1111) CID SEE DD BB.9 : BB.1 BB AA.1 A . Z.1 e 1111:0 . , ammemeamel M1 <`a! 2' X 4' RECESSED FLUORESCENT IN ACT BACK OF HOUSE N2 2' X 2' RECESSED FLUORESCENT IN ACT BACK OF HOUSE 1 1 1 I 1 1 M3 L:::: zj 2' X 4' RECESSED FLUORESCENT IN GYP. BD. BACK OF HOUSE Matta Ct OF ROOM & CASHWRAP W Ct OF ROOM S ,,_ 10'-2" 1O'- N4 2' X 2' RECESSED FLUORESCENT IN GYP. BD. BACK OF HOUSE ' ' I '' �; GYP-1 GYP- '+ ,�'' , r " " / �� EMERGENCY RECESSED FLUORESCENT WFFH BATTERY BACK OF HOUSE ,J MIMI 2-11 EQ. EQ. EQ. EQ. 11 1 - 7-2 6-10 1 -6 ( ® ,'it. TENANT-N1�G. I ATI-I AREJ� -05 2 LAMP RECESSED METAL HALIDE DOWNUGHT KIDS / BABY SALES '� ELEVATOR 10'-2" Q - - - _....:..=-...,...... ......:.:. G CEILING GYP-1 ® - -. _ =1 .AA«EDA,CA 0111.111MMODE 1111 li �� I _�I L 0 38.3 SELF CONTAINED EMERGENCY FIXTURE SALES AREA �li ��E E L ��,� PAINTED TO MATCH CEILING BACK OF HOUSE 1 -I EQ. EQ. EQ. r-e'��...a,rm.�. 1..�a� EQ. 3'-2" i�E: �m _ i / . • ct., .n "' j •t�� � � EX1 LE.D. EDGE-LIT EXIT SIGN WITH STENCIL FACE, RED LETTERS, SALES AREA Q 12-6 CLEAR FACE, BRUSHED ALUM. HOUSING AND BATTERY PACK • 44 s �s g 9 � ' G LAQ �`- i.... GYP-1 LE.D. EXIT SIGN WITH STENCIL FACE, RED LETTERS, WHITE BACK OF HOUSE BLACK ©► LAD: EV�Y / D(2 POLYCARBONATE FACE, HOUSING AND BATTERY PACK� • W _ ��! of i— :: [mdi { �� / -e,i 38 t-1•E 9� / .,, a ER i 3 G /� ©I. li ; FIXED CAMERA` R I .....� 37.9 FC BACK OF HOUSE _ ( -0"g- 4�-g".-r �_- �- ...;;, 4�_S" J TYP. W W \, D Q�� ����,'__ • ;,f • • • -Gam— I " �g 1111.,t- __ - . 1 -..:s _ ® PAN TILT ZOOM CAMERA SALES �ii ,I \� it �� •_ �,— _. ___.-___ ---_ \ / I.1 ,11 EQ• EQ �E� ��� c .— ws5 W35 35 s n N 1111111154* .°c) G \ , _ f , '� �� 11,1 EXHAUST FAN TOILET ROOMS/ \ Dil I 11111111W' EA :..:...:...::.:.: 1 \ / 11'-0" Dennis Heath, Architect Q 1 > GYP-1 SS-1 ' G c E \ / E -1 SUPPLY AIR DIFFUSER 414 g C� �, 10 _ SALES AREA 2410 Mariner Square loop• a I ash / W 1 IIILJ!7 —•—" -il—j::-- SIM. SI� Alameda CA 94h01 i 41,-- ,r .: \ / SUPPLY AIR DIFFUSER BACK OF HOUSE III 11� G 1 �a f OPEN TO ;. : G G II DIV..RED :' C LAD, Y �� RETURN AIR GRILLE SALES AREA aw m °; l ' 1 PTZ 1 �I . TO --� -•- - - / \ - --- OF ENTRY & v W ,�: :EQ " `) 1TYP ' " s"_,- ' f / \ SIGNE � BOTTOM OF I \ SALES AREA• _ ♦ _ / 8 ; u CEILING ACCESS PANEL Drawings and Wild material appearing herein constitute original r-2- A.F.F I �G I ESCALATOR G 1 `�G I - 9 P P 9 9 / \ „ lii= SALES and unpublished cork of the architect and may not be duplicated SLOT SUPPLY AIR DIFFUSER VIE . ` 5`� IIi1i -1 j \ 11 -_( �i W - "� �� i T.... .�,. _ d I - c®DH ARCHITECTS- 2010 iminummie 69 aaaw�- L=°1 { A8�1 ;^ j SLOT RETURN AIR GRILLE SALES AREA irij 1--- CD i s r Am "[VP. - W I .. _ •, '. , - �. s / \ `i SJ SPEAKER JACK SALES AREA a fr 0 A olt" Q v, ® .; ..n.h 6 No . Date Issue :•:!: 0 ROOM o N •. M L 1� G \ " ���' �.�. �� ♦ -1 ' Q il�� • "1 — or / SALES AREA 05/28/10 100% SET — W \ DJ JACK 10-2 .. Mas� s p � �- �.� / o LAD. r 05/28/10 VT PACKAGE GYP-1 I G . < < � G / \ 1 �I 1 I o I } '� .. e, \ © EXPOSED DUCT - SEE MECHANICAL DRAWINGS SALES AREA 07/02/10 100% COMPLETE SET _;:, G LAD. CLASS. " ;:� _ �, - =— , \ � ,: - _ SALES AREA 07/28/10 LANDLORD SET N ° .1 �� 1 .. .il . HIDDEN DUCT SEE MECHANICAL DRAWINGS FC 4119 .ACS + ♦ .n 1 •, .i 1 . i 08/13/10 PERMIT/BID SET 1 , I aka W � CA6 QUIVI�IERVli. =L W'TS LAD, I 12 6 '4< 6- 4W _ - - " _1 SALES AREA t 0 1C11317, Q ` �C� " "1 CATWALKS `.lr K'-10" 4'-1" G 1 4-9 4-9-,4' u_ '__j 4 1 \ 1 111 LADS o F c N lo UNIDERW g a ; c G M was was was was •G L- ' ACT_1 ACOUSTICAL CEILING TILE. SEE DETAIL 5/A6.1 b BALI( OF HOUSE W �'' was was O was was was Lc C Ca'',, C7 $.0_, a. C.. �• E C� •K9 J 1 i C 7 C.� <� ENTRY DISPLAY AREA / `I w 1 /r 2 OEM-TO SI'81H 36.1 GYP-1 "TYPE 3" GYP. B0. CEILING PAINTED WHITE PT-1. 7/6.1 b / — �� . AND SALES AREA i _—CORRIDOR i _ 10'-2" 1 '� f 1 III " I E E 1! �r,I E o I e ,,.-. 0 GYP-1 ei S GYP-2 "TYPE 4" LING PAINTED BLACK _ _------ SALES AREA GYP. BD. CEILING PT 5. 7/6.1b — - ....______ - 36 MUM_ 7'-10 1P" . ; . .a 40.;_,c GYP-3 "TYPE 5" GYP. BD. CEILING PAINTED DARK GRAY PT-3. 7/6.1b KIDS / BABY SALES AREA FLOATING CEILING A.F.F 0'-2" 9'_O" GYP-1 GYP_1 NOTE: •EQ 5'-1" EQ '-0 6'-4" 6'-4' 6'-4" EQ. 6'-7" EQ. - ALL CEILING FIXTURE TRIMS TO MATCH CEILING COLOR. REFER TO REFLECTED CEIUNG PLAN FOR INFO. � ,� '1 '- 4'-fi" / / 1 - REFER TO SHEET A6.1 a & A6.1 b FOR CEILING DETAILS M. - ALL SPEAKERS. FIRE ALARM DEVICES. SPRINKLERS. LIGHTING. HVAC AND ACCESS PANELS TO BE ALIGNED AND CENTERED IN ALL DIRECTIONS.. - REFER TO A0.1 FOR REFLECTED CEILING PLAN NOTES CEILING LEGEND - 2 111 ENTRY SOFFIT Project N o. 44122 ril fLOATING GYP....BD:....COUNG...ABOVE Scale AS NOTED ri-i CEILING MOUNTED DUPLEX RECEPTACLES 16' O.C. AT DISPLAY AREAS. SEE POWER PLANS. .:.... ;"„: 'B L O C K I N G FOR"F R I G"STANDING-FIXTURE. G.C. TO I N S T A L L"PLYWOOD SHEET':::ABOVE:::GYP.-BD:':,C EE NG'::::: D r a w n B y: DM/AN G.C. TO COORDINATE.WFTH H&M.FOR LOCATION..PRIOR TEL BID. Iii H&M SIGN. SEE ELEVATIONS FOR TYPE. c P. N I—.i—I NOT USED R:\NM\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220J∎30a.d T ED IT A• CCESS PANEL, REFER TO ELECTRICAL DRAWINGS. SEE DETAL 8/A6.1 b o Drawing No. F13- L• OCATION FOR TRAFFIC COUNTER REFLECTED CEILING PLAN [i1 N• OT USED FIRST LEVEL 1 cb Q 10 NOT USED 0 it I REFLECTED CEILING PLAN - FIRST LEVEL v8 t ' 4 REFLECTED CEILING PLAN KEYNOTES V8'=1' i A3.0a TAG SYMBOL DESCRIPTION LOCATION A 0 8 " RECESSED METAL HNJDE DOWNUGHT WITH BLACK TRIM SALES AREA Val _, - B 0 SQUARE SINGLE LAMP RECESSED METAL HALIDE DOWNUGHT WITH ENTRY / PORTAL / lii! !j: /1111111iF11111/11! - BLACK TRIM FITTING ROOMS / ALCOVE C 0_ 8. RECESSED METAL HALIDE DOWNUGHT ENTRY L, WHITE TRIM FINISH E E BLACK METAL HALIDE TRACK HEAD SALES AREA ED MEDIUM SPREAD F CO BLACK METAL HALIDE TRACK HEAD SALES AREA F SPOT SPREAD NINNm■mw■NNI■1■I■1 G ED WHITE METAL HALIDE TRACK HEAD SALES AREA G SPOT SPREAD H Eart BLACK METAL HALIDE TRACK HEAD SALES AREA H MEDIUM SPREAD US220 J MI BLACK METAL HALIDE TRACK HEAD UNDERWEAR AREA J SPOT SPREAD WASHINGTON SQUARE K gl WHITE METAL HAIJDE TRACK HEAD UNDERWEAR AREA 9585 S.W. WASHINGTON SQUARE K MEDIUM SPREAD SUITE H08 ILLUM. WALL PANEL IT L1 .=L== =, 2'-0. FLUORESCENT STRIP SEE E2.3a PORTLAND, OR 97223 L2 L1 S-011 FLUORESCENT STRIP ILLUM. WALL PANEL CLASS: RED SE E2.3a Oil:Ell , (IEI...!) 0.1.....)D (9.......9) ....3...1„.01 4... .... --**\ @,....) (10 L3 _ =====.,==== (-0. FLUORESCENT STRIP ILLUM. WALL PANEL. SE E2.3a Imilm■mmou iiim op M1 >< 2' X 4' RECESSED FLUORESCENT IN ACT BACK OF HOUSE II •milwill111101....„A II ii I iii N2 2' X 2' RECESSED FLUORESCENT IN ACT BACK OF HOUSE -.lam ii.....7.1m4 min MEM 113 r><-1 2' X 4' RECESSED FLUORESCENT IN GYP. BD. BACK OF HOUSE rilaill7.11111111 II•II•• IMJEUEIA. 2 11'. ., ..„ EQ.4 a I -- ,( i 44141 III M, II 10'-21' GYP-2 EQ. 7'-10" I-10" 31-3" N4 I 2' X 2' RECESSED FLUORESCENT IN GYP. BD. BACK OF HOUSE id (11 ,..., ruin i , 1 NIAGFIEL I I I m/N 10M4 Sex. EMERGENCY RECESSED FLUORESCENT WITH BATTERY BACK OF HOUSE ISIOS/13thi Emma= el USEAFIA II III KAI El 2 LAMP RECESSED METAL HALIDE DOWNLIGHT , KIDS / BABY SALES • 111111■41110111 ELINA121 10-2" Q I AREA FLOATING CEILING • ALAIVIEDA,CA INNEN GYP-1 -_.=_._-ffonomommir.-2 ..-----mm•-• - JIMI Ell EM SELF CONTAINED EMERGENCY FIXTURE PAINTED TO MATCH CEILING SALES AREA BACK OF HOUSE veljd e* (SO EEE, I NI. I 1 _.........■ _ milimimmmummmimmimmommimmil 1111MMMEMEMMINMUMUMMIMMEMMMIIIMMM • to -.1'7?OF 00 1111 III,1)1111111111, III 1 r-2' A.F.F U Iii - ..----;, _ _-- I I 4 ..:116 Iv . 11111.1EMEMEI .CD a ,,- ---40 I .1..) EX1 >‹1 LED. EDGE-UT DOT SIGN WITH STENCIL FACE, RED LETTERS, SALES AREA CLEAR FACE, BRUSHED ALUM. HOUSING AND BATTERY PACK II!! EX2 CR: V.I.F. I , g , 4 ..,.... to'r i' * _ t 0 - I . IIIIIIIIMIIIIEIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIMMIMIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII .4 4.6,,, 1 1 i 1 Inimm i , poLELDycAR. ExBorTNAsTEGN FwAcrrHE, STEHouNsCIINLGFACANE,D BAREDTTELETTERy pAcRSK, WHITE BACK OF HOUSE ____ IMILIg...........- -- mmilimmille==.- - _ . •-_ , - .. - 38 40 ____ MEM - MI Ell Mir WAILIJOAIEL ., li- I 0 <> CEILING SPEAKER SALES AREA - - ...NM amdm me s EN mom so - - 1 ■ e Ill 1111111111111Ti■MI i fig ,t7, g :T.iii, iii Tu iiiii iii ii Wail ii OD f I i II a 111 I dFNILIAM. -0 z., . a ...., -0 ' al il 1 ma LEM 11111111 0 bl, & e< a - - a 6 a<- _0<-- 41P I 1 stl.;)-< WINK SALES AREA In , , 0< _4.-,_ L .:‘ INEErAk Ent 111 , 1 L_ L ,„, . ALIGN WITH 0 FIXED CAMERA BACK OF HOUSE -- ct „I ,,.. si ,-, . O9 0,- MEZZNINE CLG. 8 MI I I , IIIIIIIIIIL. _ a. . , s• I 4'-Osi GO 1,_ ii' B Bi On 4TE ill'i.) Wu-- CV F" G GYP-1 0 ,...... _. wirsimimmimmilmmommi.j, UD ------- 1YR i - 1 PAN 'TILT ZOOM CAMERA SALES AREA 1 CO I . _ I :.. I Il N EXHAUST FAN TOILET ROOMS 0< al< , 4( N° a< a la IN IN i IN Nei La _ .i. - SIP MI MEM MI NUN NI MEM In -- -' 11111111191111, v,' 1.-3 51-1- 0. 1 14,4 ,Ir I ____ 2 -..--I --r.%AL.' ---,--,, Dennis Heath, Architect ...- a In 0 III , A r G y G%- At ‘7° I 1 .„9 7.0 UJ SUPPLY AIR DIFFUSER SALES AREA 1), lorLj 0 hit 1 , !Pt ,..... .,, ___. p IIIII'D‹ '. , I C c i 1 2410 Mariner Square Loop r ...e. 0 . ■4 ■L. . I 1 lain 4110 maDa .441. a 111F4 f -0, I ir X *I L° F -F 1 d SUPPLY AIR DIFFUSER BACK OF HOUSE Alameda, CA 94501 A e 4 4:44(,_ 0.< _0, -,L. - 0 1 G bal. , , , im 6. I, 'in G' .1..... • 11 -A = * , a.... 11 %MICK \ RETURN MR GRILLE SALES AREA 1 I I 0 ill-- , 1 al 11 .4 ,40:01,:::F.t.tica.: ,„ k z...00,:••,,,,,:.: 130Nrsii.... ::,::,..=... ,:i iz... p..146.:...:1, oei1, ) g - La ,Typt, OAP ... ilpgi ir.:5,,, irl 4P' 6 , .!.5,.., aci40 W350 W35 , I P I A CEILING ACCESS PANEL SALES AREA = iic) V 450 1 q , ,.,,_, i 1 0 MEi. inir.I ral t. D 1__. 4!)- i !" i ‘ C- .. ier).1 C1j - A iii 4 0 :. prithg3 I i d trittei material appearing herein constitute original ..0 t12.)- :Jo ' 71-6 aa-, • J.: it° -1.■ +Y ., 1 . r i p 0410.- =SAO' and unpublished tort of tie Architect and mag Nat be duplicated, tprt ======m SLOT SUPPLY AIR DIFFUSER SALES AREA UJ I 4111bg 411Dg F igtiin 1 01-2" used or disclosed without vritten consent of the Architect I PI dr 3e<-. a I OP F F 7 *II I Ell VP-1 7,) 4if I l'‘1. - _4 I AM. 4-T-1 0 1/2. A.F.F V.I.F. In ir 4 (, GYP-2 fit ' ®DH ARCHITECTS- 2 0 10 _ -.- - ..1=111= -..'"-- - ? ___ . 7.-2* ow :---_-=. - - _ C , 11 m======= SLOT RETURN AIR GRILLE SALES AREA A.F.F mili _________ _ 1................._ _ I EID __- • IT F o cirR GI I _i•a As ;Ai 4. .It. . EUYIK Nip V.I.F. 1 I I I In ullir ---- -1: ' QAQC Ø g II. ''' Ell SPEAKER JACK SALES AREA 0< ---T •<- i< I < 1 e No . Dote Issue cce -LI tip 15 CD ‘O 450 io iv . , r-., -° SALES AREA , .. F 4 , .11114 UJ DJ DJ JACK 05/28/10 100% SET r 1 . 4 LLI I I 1 ) @ I o< 4-7 0 '4P ci 1 sw -. ?Amw_410 05/28/10 VT PACKAGE i I 1 ■r---')) 0, SALES AREA lYP. - " 1 45 ---O- 16.1,il ,8,:45 il<4--F...2. 'Its-- ,,e . 4 - - . -45----- -----0 [.:_- L 1 EXPOSED DUCT - SEE MECHANICAL DRAWINGS eolks. AF ?$--,- _ 1114 I 0211* 07/02/10 100% COMPLETE SET iii 4 0 0‹ -----0 mum. 414 6 e4, ci - - - G1 UJ HIDDEN DUCT - SEE MECHANICAL DRAWINGS a !III G I r 0,1*, - - - 08/13/10 PERMIT/BID SET :A .0. A61. t 1 ilk 1. I. 4 a 1 1 UJ II ---ri 111' ® SALES AREA 07/28/10 LANDLORD SET wi '1 TYP. 0 G• (V -----411 9 „ a CATWALKS SALES AREA 1 r••• -V. , ___ 1 ____??< ______,t t , 1 13CIP < 1 all III ll 111 i 1 e e _ G____ -0±______ 1 Ni1P1 Li.-1 -10.431-101BilLS.-1• BiiLLY-10. lel) D: :::-----1- als , 1 a c? um ll a 7 I '5';'' J 0 s ;, r.----- 6-0 I 9 1///NNIMMI.IINIMMINN■A•111=111•11 I IMP, - a 1 Mill 11 o- 0.1 - t ...mi ACT-1 ACOUSTICAL CEIUNG TILE SEE DETAIL 5/A6 lb BACK OF HOUSE -,----,,,, W35 5 a 0 450 wo35. 0 0 4. 1 ENTRY / DISPLAY AREA / a CD I TYPo<I • VI _ A6.1. GYP-1 °TYPE 3. GYP. BD. CEILING PAINTED WHITE PT-1. 7/6.1b AND SALES AREA I _ • .... ., •< i ly I I 1 1 TYP. , =MI ..ti 1 I NI -I 1 1 1111 . 1. 11:00...:Me. 1111 Vill al Ell MM.NM SALES AREA .EMI MN IEEE ON - 1 1 I 1 III I b GYP-2 fr - iii L i - L - - - 36 - _ L,3 _______--___ L„ L e L 1 , "TYPE 4. GYP. BD. CEILING PAINTED BLACK PT-5. 7/6.1b GYP-3 • 'TYPE 5. GYP. BD. CEILING PAINTED DARK GRAY PT-3. 7/6.1b KIDS / BABY SALES KIDS I BABY 111 AREA FLOATING CEILING .111...._A l a fiiMABEA 1:,..,,i k _ mai 101-2" - ALL CEIUNG FIXTURE TRIMS TO MATCH CEIUNG COLOR. REFER TO REFLECTED CEIUNG PLAN FOR INFO. GYP-1 - REFER TO SHEET A6.1a & A6.1b FOR CEILING DETAILS S-0" EQ. EQ. EQ. EQ. EQ. EQ. EQ. 3'-0" 3'-0" EQ. EQ. EQ. EQ. 2-11" EQ. 7'4- EQ. - ALL SPEAKERS. FIRE ALARM DEVICES. SPRINKLERS. LIGHTING. HVAC AND ACCESS PAN 3 S TO BE ALIGNED AND 1 / , / CENTERED IN ALL DIRECTIONS, - REFER TO A0.1 FOR REFLECTED CEILING PLAN NOTES CEILING LEGEND I ... _ 2 Fil....ENTRY...SOFFIT Project No. 441 22 1:11°i ii. :Ea ik G.:1 1 1-i- F• LOATING GYP. BM CEILING ABOVE Scale AS NOTED 10 CEIUNG MOUNTED DUPLEX RECEPTACLES 161 0.C. AT DISPLAY AREAS. SEE POWER FUNS. IT BLOCKING FOR FREE STANDING FIXTURE. G.C. TO INSTALL PLYWOOD SHEET ABOVE GYP. BD. CEIUNG. DrawnBy: DM/AN G.C. TO COORDINATE WITH H&M FOR LOCATION PRIOR TO BID. O 1-51 H• &M Sat SEE EtEVATIONS FOR TYPE. 0 m E.' 6 NOT USED >.. N RAHM\Projects\2010.2rojects\44122 Washington Sq\Drawings\CD\US220.,..A30b.O ..0 L 7 ACCESS PANEL REFER TO ELECTRICAL DRAWINGS. SEE DETAL 8/A6.1b Drawing No. Fl LOCATION FOR TRAMC'COUNTER. ' Es ED CV REFLECTED CEILING PLAN " IT N• OT USED MEZZANINE LEVEL I,' .., Fol N• OT USED .. >, . 7, _ 1/814-0" _.1 F1/84-0" 4 REFLECTED CEILING PLAN KEYNOTES 1 1 REFLECTED CEILING PLAN .... MEZZANINE LEVEL A3 .0b .... 36 38 36 38 :;111!'llillP1111/ 11/11! I PT-2 2- I PT I PT-2 I PT-2 I I PT-2 I PT-2 _p #11226 #11243 #11227 #11225 • #11243 • / #11226 #11243 • #11225/ \ B.O. CEILING 11225 #11243 • #11225 • \ • 10-2 A.F.F. \ � " # #1122fi #11227 #11243 #11225 B.O. CEILING - - 9-fi A.F.F. \ / \ / / \ \ / - 9'-'6" A.F.F. \ T.O. WARDROBES _ _ \ / _ 0) ammommis■■= 1 \ / / \ / T.O. WARDROBES EN� �' ` EQ. \ \ / OP4S141/i0 0430 x0 ADJAC ROOM a , ENT T\ / T. / \ \ / \ WASHINGTON SQUARE / \ / / \ 9585 S.W. WASHINGTON SQUARE - - - - - - - - - \ / \ - - - - _ ,_ " / \ SUITE Hob ,__: �� \ _ _ _ �. o a A.F.F. / - PORTLAND, OR 97223 11228812 11228812 11229812 11228812 11 —1 \�'�i - 0 0 A.F.F. # # WARDROBE FIXTURES # 228812 WARDROBE FIXTURES FINISH FLOOR CLASS: RED/ COLUMN BEYOND / / WARDROBE FIXTURES WARDROBE FIXTURES FINISH FLOOR p WITH CUPBOARD AND DRAWERS WB_1 rn,� WITH CUPBOARD / / COLUMN BEYOND / / I I WITH CUPBOARD WB-1 ,. WITH CUPBOARD .................................... INTERIOR ELEVATION vent-o"' 1/44=r-o�' 8 INTERIOR ELEVATION 4 AA BB AA I PT-2 P1-6 PT-2 1.....- PT-2 IPT-2 COLUMN IN I • FOREGROUND " SHOWN DASHED " I\'�,► 1 f / 10'-2" A.F.F. _ 10 2 A.F.F. �,�;ill ,,.'1_#11226 • #11243 • #11225 #11243 B.O. CEILING ' L. #11226 #11243 #11 5 I 111226 #11243 • r l' 5 L._ #11225 B.O. CEILING ,,iii ve: • -----N-----\ 9'-6" A.F.F. • - _ ( - 9'-6" A.F.F. IS HEATH Cri T.O. WARDROBES V - - - - T.O. WARDROBES V ,...� < I PT-6 I > EQ. -/-/- EQ. ,%:/ / � a 4oF 0W I I I I \ ' ] < / / ' ENNINI■momm■■■■■ < \ - I- - \ \ , /� , ®-t - - - 0'-a" A.F.F. — - ' :t`. _ / 0'-0" A.F.F.di #11228B12 #11228B12 � #11228812 #11228812 FINISH FLOOR FINISH FLOOR WARDROBE FIXTURES WARDROBE FIXTURES I WB-1 ENTRY WARDROBE FIXTURES WARDROBE FIXTURES / / / / / / / / WITH CUPBOARD AND DRAWERS WITH CUPBOARD AND DRAWERS WITH CUPBOARD WITH CUPWJARD I WB-1 TYP. Heath, Architect INTERIOR ELEVATION v4":rte 17 INTERIOR ELEVATION 1/44=r- 3 Dennis Dennis Mariner S u a r e loop 0 q p Alameda, CA 94501 38 36 38 36 IDrawings and written material appearing herein constitute original —2 I —2 I PT 2 I I —2 I PT-2 I —2 cad un p ublished work of the Architect and me! not be duplicated, used or disclosed without written consent of the Architect 9 10'-2" A.F.F. � " c(�DN ARCHITECTS-2010 #11226 #11243 • #11225 • 11226 • #11243 #11227 11225 11243 ,, I I - • • 10-2 A.F.F. ,,,___P \ 7 • \ # # # # # B.O. CEILING #11226 #11243 #11227 #11225 / #11226 #11227 #11243 #11225 B.O. CEILING V Q A Q C \ ---- -\9'-6" A.F.F. - / - 9'-6" A.F.F.N \ / _ _ _ _ _ _ _ _ \ _ - - _ No . Date Issue T.O. WARDROBES / T.Q. WARDROBES \ / \ \ � V 05/28/10 100% SET )9; YQ. / / 05/28/10 UT PACKAGE 4> / 010 TO �� :; AID,IAC ROOM OPEN 07/02/10 100% COMPLETE SET L\ 07/28/10 LANDLORD SET / / \ N 08/13/10 PERMIT/BID SET / / \ N 7. . . _ / \s - \-- -____, 01_0. A.F.F. i \-- O'-O" A.F.F. I #112 8612 #11228612 #11229B12 #11228812 #11228B12 FlNISH FLOOR FlNISH FLOOR / WARDROBE FIXTURES / COLUMN BEYOND / WARDROBE FIXTURES / / WARDROBE FIXTURES �, COLUMN BEYOND / WARDROBE FIXTURES WITH CUPBOARD I we-i ''r,, WITH CUPBOARD AND DRAWERS WITH CUPBOARD WITH CUPBOARD I 1_1 , TYP. DRAWER NUMBER, TYP. INTERIOR ELEVATION v4•°r-o" 1/4 t-o'- 6 INTERIOR ELEVATION 2 e BB AA AA 0 0 A _ 1 PT-2 CUPBOARD NUMBER, TYP. I PT-2 I • COLUMN IN COLUMN IN FOREGROUND FOREGROUND SHOWN DASHED SHOWN DASHED 1O'-2" A.F.F. 10'-2" A.F.F. #11226 #11227 #11243 111225 I #11226 #11243 • #11227 #11225 B.O. CEILING #11226 #11227 #11243 #11225 • cip #11226 #11243 #11227 #11225 B.O. CEILING - 1 - \ 9`-6" A.F.F. _ _ " Project No. 44122 ` 1 9'-6- A.F.F. - - - - - - - - T.O. WARDROBES V T.O. WARDROBES Q., tl .;: ��EQ. Scale AS NOTED // // I DrawnRy: DM/AN 1 fi, I R:\Hld\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220_/441a.d E co I. V-0" A.F.F. — -- -- --- _: ,------ — __� 0`—a" A.F.F. Drawing N o. o FINISH FLOOR FINISH FLOOR / WARDROBE FIXTURES WARDROBE FIXTURES WARDROBE FIXTURES WARDROBE FIXTURES INTERIOR ELEVATIONS N FIRST LEVEL N WITH CUPBOARD / WITH CUPBOARD / WITH CUPBOARD / WITH CUPBOARD f-WB-1 TOP. I we-i TYP. I V4 1-o� 4•° -o�I ELEVATION 5 INTERIOR ELEVATION i A4.la 38 36 y PT-2 I PT-2 I PT-2 //////74114! i 10'-2" A.F.F.dk ___J-- • #11226 \ / • \ 7 #11225 • #11243 #11227 #11226 #11243 B.Q. CEILING — \ / 9'-6" A.F.F. T.O. WARDROBES— — — W ROBES \ i \ / OF_I■ TO ADJAC ROOM US220 WASHINGTON SQUARE / / \ \ 9585 S.W. WASHINGTON SQUARE / / \ SUITE HO8 ,,_____ . _ :-/ \- 0'-0" A.F.F. PORTLAND, OR 97223 1 FINISH FLOOR CLASS: RED 4yARDROBE FIXTUR COLUMN BEYOND / WARDROBE FIXTURES WITH CUPBOARD WITH CUPBOARD I WB-1 TYP. ...................................... INTERIOR ELEVATION 1/4"=t- 8 INTERIOR ELEVATION 114114-0" 4 0 DD 38 I P7-2 I I PT-2 I PT-2 10'-2" A.F.F. 10'-2" A.F.F. \' ,'#11225 #11243 #11226 #11243 #11225 #11243 • #11226 #11243 B.O. CEILING #11226 #11243 __p #11225 #11243 • B.O. CEILING � ----\ ----\91-6" A.F.F. — 91-6" A.F.F.dil — — — — — T.O. WARDROBES — — — T.O. WARDROBES // // ALAMED , CA 4?Op o .-_ :; 0'-0" A.F.F. Oi_0» �...� A.F.F.chi �' �i FINISH FLOOR SERVICE n FINISH FLOOR / WARDROBE FIXTURES / / WARDROBE FIXTURES / / WARDROBE FIXTURES / BEYOND ELEVATOR WITH CUPBOARD WITH CUPBOARD I WB-1 I TYP. WITH CUPBOARD -1 ' 1/4"=1'-0' 11464-47 DII Dennis Heath, Architect INTERIOR ELEVATION 7 INTERIOR ELEVATION 2470 Mariner Square loop Alameda, CA 94501 36 DD Dreriag3 and written material appearing herein constitute origiaal —2 I -2 I and unpublished wort of the Architect and may duplicoted, not be P used or disclosed without written consent of the Architect ®DH ARCHITECTS-2010 10'-2" A.F.F. j 10'-2" A.F.F.di #11225 #11243 • #11226 #11243 B.O. CEILING Q A Q C #1122fi #11243 • #11225 #11243 B.O. COUNG -----\ — 9'-6" A.F.F. — 9'-6" A.F.F. \ — — T.Q. WARDROBES V T.O. WARDROBES No . Dote Issue \ / 05/28/10 _ 100% SET \ / 05/28/10 VT PACKAGE \ / 07/02/10 100% COMPLETE SET •.1 TO <> 07/28/10 LANDLORD SET ° Fl ' ROOM 08/13/10 PERMIT/BID SET / ARE / \ , -_-- 1 \ \ — -�. 0'-0" A.F.F.d k ___ 0'-0" A.F.F.chi FINISH FLOOR FINISH FLOOR / WARDROBE FIXTURES / / WARDROBE FIXTURES / WARDROBE FIXTURES ir WITH CUPBOARD WITH CUPBOARD yyB_1 TYP, WITH CUPBOARD I WB-1 TYP. 1/011-0" 14=10INTERIOR ELEVATION 6 INTERIOR ELEVATION _ 2 0 DD ID DD ID I PT-2 I CUPBOARD NUMBER, TYP.–, I PT-2---)10'-2" A.F.F. 1O'-2" A.F.F.,,,,,, ..._p #11225 #11243 #11227 • #11226 #11243 B.O. CEILING #11226 #11243 #11225 #11243 #11226 #11243 • #11225 #11243 B.O. CEILING-------\— 9'-6" A.F.F. - - 9'-6" A.F.F. Project N o. 44122 — — — T.O. WARDROBES — — — — — — T.O. WARDROBES EQ,.;:;;` 1EC. EQ.:'>>`" E Q► S c a l e AS NOTED DrownBy: DM/AN f' E 0 v IT I R:\HM\Projects\2010_Projects\44122 Washington Sq\Drowings\CD\US22OJ141 b.d E a co O' 0" A.F.F. _ _ 01-0" A.FF. Drawing No ° I FINISH FLOOR FINISH FLOOR INTERIOR ELEVATIONS " I, WARDROBE FIXTURES / / WARDROBE FIXTURES / / WARDROBE FIXTURES FIRST LEVEL WrrH CUPBOARD WB-1 WITH CUPBOARD WITH CUPBOARD S H I I WB-1 TYP. Q V4"=1-0' 1/4114-Or" _. INTERIOR ELEVATION 5 INTERIOR ELEVATION i A4.1b 36 38 AA PT-2 PT-2 IPT-21 ) 10—2 AF.F. 1 N 10'-2" AF.F.di • • B.O. CEIUNG , B.O. CEIUNG \ / \ --- \ / 9'—o" A.F.F. 9'-0" A.F.F. \ T.O. WARDROBES \ / / T.O. WARDROBES \ / \ OPVV,�TTO 0' i US220 ADJACENI\ROOM 1 / \ WASHINGTON SQUARE / \ / \ / 9585 S.W. WASHINGTON SQUARE \ SUITE H08 / \ / PORTLAND OR 97223\— 0'-0" A.F.F. —�.� O'-0" A.F.F. II FINISH FLOOR FINISH FLOOR CLASS: RED I COLUMN BEYOND WARDROBE FIXTURES ._1 WARDROBE FIXTURES WARDROBE FIXTURES WB-1 ' / PT-2 / / / ............................ V4'=?-Q' 1!4' 1-Or' INTERIOR ELEVATION 8 INTERIOR ELEVATION 4 BB 0 0 I PT-2 JF) .6 I I PT-2 PT-2 BEYOND Ili • 1.--) L--- 10—2 A.F.F. T 1 1 IT 10—2 A.F.F.dik B.O. CEIUNG '' , ■ • • B.O. CEILING • • so ,! t . Arj C) 9'-0" A.F.F. 9'-0" A.F.F. • T.O. WARDROBES T.O. WARDROBES • ALAMEDA. CA • < H61 > *) ' 4'OFO II--_---------- I GLASS RAIL - . — — , .._ — , .. =�T-- 0'-0" A.F.F. �, CAOHWRAP FINISH FLOOR I I I 1 FINISH FLOOR / WARDROBE FIXTURES / / WARDROBE FIXTURES -1 '• IV WARDROBE FIXTURES / / Dennis Heath, Architect INTERIOR ELEVATION _ 7 INTERIOR ELEVATION 3 2410 Mariner Square Lapp Alameda, CA 94501 38 36 38 Drawings and Willi Material appearing herein constitute original cad unpublished cork of the Architect and may not be duplicated, I PT-2 1 I PT-2 I PT-2 I used or disclosed vithout 'Hite' consent of the Architect c®DH ARCHITECTS-2010 T `, 10'-2" A.F.F. 'J L 1r 10'-2" A.F.F. • \ / \ / • B.O. CEIUNG V \ / • B.O. CEIUNG IV Q A Q C \ / \ / — N / \ -----\9'—O" A.F.F.A.F.F. -0" A.F.F. No . Date Issue \ / \ / \ T.O. WARDROBES \ \ / T.O. WARDROBES IV \ / ` \ 05/28/10 VT PACKAGE \ / \ \ / OPEN 0 0'1, TO TO 0 0 0 EN 07/02/10 100% ADJAC a0 ROOM ROOM ROOM ADJAC 3 COMPLETE SET <><> \ RI+M 07/28/10 LANDLORD SET / \ / \ \ / \ \ / \ / / \ 08/13/10 PERMIT/BID SET / \ / \ \ / \ / — a o A.F.F. / \ / �, " _ .�® / �® - - ran _ - a _ —� -/ — _ _ _r—�._,� A.F.F.aih 0 0 1 FINISH FLOOR Iti 1 1 FINISH FLOOR COLUMN BEYOND I WB-1 TYP. I WB_1 rn,. COLUMN BEYOND / WARDROBE FIXTURES / P1-2 / WARDROBE FIXTURES / / , WARDROBE FIXTURES / / WARDROBE FIXTURES / INTERIOR ELEVATION _ 6 INTERIOR ELEVATION 2 e BB AA 0 I PT-2 PT-2 T ç_w 10'-2" A.F.F.dh T I 1O'-2" A.F.F.clk • B.O. CEILING , B.O. CEIUNG 11 Project N o. 44122 —` 0— 9 -----\' A.F.F. 9'-0" A.F.F.dk 7 T.O. WARDROBES T.O. WARDROBES II Ea,;:<'�'�... :;-�Et� Scale AS NOTED ;` .r, DrawnBy: DM/AN i <> In E 0 i R:\HM\Projects\2010_Projects\44122 Washington Sq\Drowings\CD\US220J141 c.0 E �n 0'-0" A.F.F. �— - - - - - - . _ . _ _ _ N 0' 0" A.F.F. Drawing N o. FINISH FLOOR V FINISH FLOOR V INTERIOR ELEVATIONS Ni WB-1 TYR I we-1_ TYP. MEZZANINE LEVEL / WARDROBE FIXTURES / / WARDROBE FIXTURES / / WARDROBE FIXTURES / N O 1/4'=f-01' veer-of .3 INTERIOR ELEVATION 5 INTERIOR ELEVATION 1 A4.1c 36 G 7114/11/ MIRROR FOR WALL PANEL. GC. TO FIX MIRROR ON THE DETAIL RAIL OF THE WALL PANEL, 1W. PT-2 I PT-4I PT-2 / / SG-1 10'-2" A.F.F. B.O. CEILING cs 't'A US220 .. .. .. .. WASHINGTON SQUARE 9585 S.W. WASHINGTON SQUARE ek ` - 1 0 SUITE H08 W PORTLAND, OR 97223 121. L n p--t. «r—, 0'-0" A.F.F.ak _ FREE STANDING FRAME FINISH FLOOR V CLASS: RED I WB-1 I TYP. WALL PANELS WALL PANELS WB-1 TYP. INTERIOR ELEVATION 1/4"=?-0" 8 NOT USED _ 4 0 DD 38 I PT-2 I : Il:T PT-2 _ / / I PT 2 PT-2 /� 10'-2" A.F.F. 10'-2" A.F.F. I B.O. CEILING B.O. CEILING Ivii( . • r • f�., ,�� E. ,mss' cap °� v� •► P"� TT t � r� �- � ALAMg��,, (f*A) ''Cll' .. .. Al ., 8OFOØ \ / 1 TA ' r car °� / w n-� —r„ w .. " 0'-0" A.F.F. ``' ,t-r-- �--�-� _ 0'-0" A.F.F. FIDE STANDING FRAME FINISH FLOOR SERVICE FINISH FLOOR WB-1 TYP. _1 TYP. ELEVATOR / WALL PANELS / / WALL PANELS / / WALL PANELS / BEYOND I 1/4" 1-V• . Dennis Heath, Architect INTERIOR ELEVATION 7 INTERIOR ELEVATION 3 2 4 7 0 Mariner Square L o o 1/4 Alameda, CA 94501 36 DD (130 Draeiags and written material appearing herein constitute original and unpublished work of the Architect and may not be duplicated, PT-2 I PT-2 2'-10" A used or disclosed without written consent of the Architect ®DH ARCHITECTS- 2010 f 10'-2" A.F.F. 1 1O'-2" A.F.F.dik B.O. CEILING • B.O. CEILING Q A Q C a' w �� No . Date Issue \ / 05/28/10 100% SET I \ / 05/28/10 VT PACKAGE , , \ / « 07/02/10 100% COMPLETE SET N Z 0 TO 07/28/10 LANDLORD SET ADJACP ROOM `� x 08/13/10 PERMIT/BID ( co I SET 1 / \ W 0 I \ , it r�� „nT O'-0" A.F.F. ``' I -�-�,, „�/ \ \ 0'-0" A.F.F.cja FINISH FLOOR I FINISH FLOOR I WB-1 TYP. WB-1 M. " / WALL PANELS / WALL PANELS // fi-0 / / WALL PANELS / ROUGH OPENING INTERIOR ELEVATION 1/4•°r-°" 114•=r-0= _ 6 INTERIOR ELEVATION 2 iso DD Go DD ei) I P1-2 1 P1-2 PT-4 P1-2 / / I 1O'-2" A.F.F. SG-1 � " 10-2 A.F.F.cik B.O. CEIUNG B.O. CEIUNG Project N o. 44122 �, EQ. / / EQ. / • a sf \ / Scale AS NOTED \ / EQ. :.' EQ. / /./.' / / DrarrnBy: DM/AN \ / ��O/P 14 TO ROOM <> S c ADJ 1' ROOM 4 - R:\HM\Projects\2010_Projects\44122 Washington Sq\Drowrngs\CD\US220�141 d.0 / \ Qr Q .-�� \ ,.. W 0'-0" AF.F. ``' �� 0'-0" Al.F. Drawing No. ° I FINISH FLOOR FREE STANDING FRAME F FINISH FLOOR INTERIOR ELEVATIONS EvATIONS I vie-1 TYP. MEZZANINE LEVEL WAIL PANELS WALL PANELS i,wB_1 TYP. WALL PANELS / / / / / / WALL PANELS / T O _. INTERIOR ELEVATION V4Mf 5 INTERIOR ELEVATION 1/4W-0" i --ti. A4.1d 36 38 :1/4,11irlIllillir'14111/ 11/1! 1 2 A5.1 A5.1 STAINLESS STEEL VERTICAL SEAMS TO US220 ALIGN WITH GLASS BUTT JOINT 1:/5/38k5Sspc)F. ING TON SQ LIAR• (E) MALL (E) MALL 48"H WALL MOUNTED SIGN OF ENTRY, METAL SEAM do SIGN BULKHEAD BULKHEAD ° W. WASHINGTON SQUAR14-0 A.F.F. (V.LF.)B.O. BULKHEAD 97223 .>. .. . .. :.�>; STAINLESS .,, . . . : . ., . .; . ., , .-. __- __ _-_ __. ._, . . . :.,;: . _ . ...�. :. E MALL STEEL CLADDING TYP. . ::.::. : :; . :.:.:. .. . ..::.. . .. :_. _;:: . . . .. .,:: . .. . ::'. . ..::. . :..:.... . :_. — A.F.F. 34R - : 12 6 REVEAL ON SS 1 -- - . . . . ; . . : . . . , _ CLASS: RED T.O. DISPLAY WINDOW NEUTRAL PIER, TYP. r-S. :, � 11 0 A.F.F. ' f T.O. ENTRY { A5, ;i'ry,p. r C •— 5/8" CLEAR TEMPERED GLAZING, TYP. T GL-1 II LEASE UNE `� — • 1,4_ < LEASE LINE �PEN_TO- ° I ,-BEYOND---- CLADDING, STAINLESS STEEL CLAD 3" "HdcM" VINYL OVER (E) NEUTRAL PIER, LOGO DECAL, TYP. 4 TYP. BOTH SIDES 4" STAINLESS STEEL BASE REVERSE READING A5 2 is W �_1 OF WINDOW SHOE APPLIED DIRECTLY - , dr TYP. _ ,f ,.,. I, TO INTERIOR GLASS •.M i11M III # - « N s '! 11, 4 _ 0 0 Jill'1Y A 1 FINISH FLOOR •; , r• 1 1/2" X 1 1/2" COLUMN BEYOND t"" STAINLESS STEEL ROLLING GRILLE REFER TO DOOR STAINLESS STEEL SEAM AT BASE- 5/8" CLEAR TEMPERED GLAZING, TYP, C OF OV''' TO ALIGN WITH GLASS BUTT JOINT " ALAMEDA, CA • CLADDING CUPS SCHEDULE, 3/i�.3 GL-1 � 4" STAINLESS STEEL BASE .r'2' �`° ' OF WINDOW SHOE ''it STAINLESS STEEL CLADDING SS-1 moo wows ADJANCENT DISPLAY WINDOW / 2?'-6" / DISPLAY WINDOW / / ADJANCENT _ TENANT 5 EQ. PANELS ENTRY 3 EQ. PANELS TENANT SIDE ELEVATION FRONT ELEVATION B A 1/4"=1`-07' Dennis Heath, Architect INTERIORSTOREFRONTELEVATION _ 2 2470 Mariner Square loop Alameda, CA 94501 36 38 Droninga and trifle. material appearing herein constitute original and unpublished rork of the Architect and moy not be duplicated, used or disclosed fithout orilten consent of the Architect c®DH ARCHITECTS- 201D QAQC No . Date Issue LINE OF SOFFIT/BULKHEAD 05/28/10 100% SET ABOVE SHOWN DASHED 05/28/10 VT PACKAGE FLOOR MAX SYSTEM, TYP OF (4) 07/02/10 100% COMPLETE SET LINE OF ROLLING GRILLE. c. OF SIGN AND ENTRY FLOOR & CEILING 07/28/10 LANDLORD SET SEE DOOR SCHEDULE OUTLET, 08/13/10 PERMIT/BID SET 1 2 ' A5.1 A5.1 II I , , \ ç% r. _q,%Y lI Y L Y Y Y N Y Y Y Y .. Y Y k _ 0 ill: 3Z;E rj:ll i) 0 1 I rTh3 , Io , .... ........,. 1: A5.2 7 f , 1 2 1 t_� i 1 1 ZB V LJJ ijj ® - - - - - _ - _- --- 2B Al DPP. N � N 5/8 CLEAR TEMPERED GLAZING, TYP. A5.2 5/8 CLEAR TEMPERED GLAZING, TYP. GL-1 48" WALL MOUNTED SIGN GL-1 G.C. TO VERIFY CONDITION OF NEUTRAL PIER AND NOTIFY OWNER OF ANY DISCREPANCY FROM DRAWINGS, TYP. ON Project N a. 44122 GYP BD. WALL BEYOND GYP BD. WALL BEYOND BOTH SIDES LEASEUNE -2 -2 Scale AS NOTED BUILD UP PODIUM /41[113h\ BUILD UP PODIUM MDF IPT-io MDF IPT-io Dra,rnBy: DM/AN 1'—O" 21'-7 3/4" 2'-O" 2?'-6" 2'-0" 14'-9 7/8" 1'-0" DISPLAY WINDOW ENTRY DISPLAY WINDOW 0,0 2 \\AL4\CadMate\HM\Projects\2010_Projects\44122 Washington Sq\Drowinga\CD\US22 70'-O" / ,r Drawing No. O N STOREFRONT STOREFRONT PLAN ELEVATION / PLAN A 0,. it 1/41=t-o" 1 y Q a a INTERIOR STOREFRONT PLAN A 5 .0 :0 — ALL STOREFRONT CONSTRUCTION — ALL STOREFRONT CONSTRUCTION :;/P1(111//lidilllir4111// 11/11! SHALL BE SELT SUPPORTING FROM SHALL BE SELT SUPPORTING FROM THE FLOOR THE FLOOR — FOR FRAMING SIZE, GAUGE AND — FOR FRAMING SIZE, GAUGE AND CONFIGURATION REFER TO CONFIGURATION REFER TO STRUCTURAL DRAWINGS STRUCTURAL DRAWINGS — ALL PLYWOOD AND BLOCKING TO — ALL PLYWOOD AND BLOCKING TO GIBE F.R.P. BE FR?. ...............- US220 WASHINGTON SQUARE 9585 S.W. WASHINGTON SQUARE SUITE H08 PORTLAND OR 97223 CLASS RED f.. % f!. ,r r'! ; %!% ; i. is ;: ;i f,. / / fJ: /,� i frf ; f j" / f� f / %l J: /r r frr i�. Q 0 l L i i i' i { fa..*- ii+v: !� ,i,� �i, t (E) MALL BULKHEAD j SHOWN ■ IS HEATH (E) MALL BULKHEAD A ED , • A SHOWN LAM (**1> ''' '' ;!J , - - „- . /- I; ■F 'e OF j ! f i. . ji' w A.F.F. N.I.F. f!; f,. , r* '5 1 4 r 8 r w .2 ' Bk. MALL BULKHEAD Iii 2s :::f:i /---.......si/ 2—s w w 1111111 14'-0" A.F.F. i 14'-0" A.F.F.dil . . . 03_ STOREFRONT T.O. STOREFRONT T.O. ST I ROWNG GRILLE WITH . FRONT LOADED MOTOR R t(E) COLUMN > BY ROWNG GRILLE MANUFACTURER ,f' / !i! — w IT P BU L U BOX . . . . . . . . . BEAM — REFER . . 1V-0" A.F.F. (V.I.F.) Dennis Heath, Architect • • • . . . . B.O. BULKHEAD— = STRUCTURAL JI<CONVENIENCE ... .. . .. ... — . > ' BUILT—UP BOX OUTLETS, SHOWN �`�FRAMING,T.O. DISPLAY WNDOW I SEE STRUCTURAL i , :. J_T:1 > . . �f • L SEE STRUCTURAL _ REFLECTING . . gill __ • 10'-0" A.F.F. DRAWINGS > CEILING PLAN — _�' n Drawings and written material appearing herein constitute original T.O. ENTRY and unpublished work of the Architect and mat not be duplicated, FINISHED GYP.. . 12 INTERNALLY ILLUMINATED used or disclosed rithout written consent of the Architect - . - j • - BD. CEILING, w c DH ARCHITECTS- 2010 48 WALL MOUNTED SIGN__� REFER TO RCP. SIGN, SEE DETAIL 8/A5.2`' QAQC.1 < LEASE LINE STAINLESS STEEL No . Date Issue PANEL SS-1 05 28 10 100 SET < 5/8" CLEAR / /'WARDROBE' TEMPERED GLASS 05/28/10 VT PACKAGE FlXTURES GL-1 07/02/10 100 COMPLETE SET �M > 5/8' CLEAR 07/28/10 LANDLORD SET TEMPERED GLASS EMP < LEASE UNE 08/13/10 PERMIT/BID SET I > UNE OF GYP. BD. UNE OF GYP. BD. WALL BEYOND WALL BEYOND > SAL EA AREA �/AI AAA t�AI FR AI�F/I► VAI�A__/h a EQ. EQ. ROWNG GRILLE EMERGENCY PULL PLANKS TO BE CUT AND DISPLAY GLASS BD. WALL LAY IN BY GC. PRODUCT I BEYOND PROVIDED BY H&M DOtX2 AND SIDE I LIGHT, SHOWN PT-10 MDF SURFACE OVER BEYOND. REFER TO ROWNG GRILLE DO(Xi TYPE AT PLYWOOD OVER METAL SHEET A0.3 KEY SWITCH • STUD FRAMING. PLANKS TO BE PROVIDED BY H&M. G.C. TO CUT & f EQ. EQ. INSTALL PER H&M c • < KEY SWITCH FINISH DIRECTION r y TO MATCH ss-1 MDF .- I WOOD BASE CONVENIENCE 4' , GLASS SHOE MUWON WB-1 0�, SHOWN � ' '/ ,Ir " o v DASHED SS-1 N l r Project No. 44122 CV \\I — —(E) MALL FINISH d.... .. .. .:. f::r _ _ _ —11:i S c a l e AS NOTED 1 II, iA— — - 01—O' A.F.F.A E 0l-0" A.F.F. FINISH FLOOR t FINISH FLOOR V DrawnBy: DM/AN EIN LLT-1 E ME ► < / > < / .2 i R:\HM\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220J151.d g_ qi Drawing No. O 0 N STOREFRONT Ni SECTIONS TA Q — 3/4"4-0' 3/414-0" _0., NOT USED 3 SECTION THRU DISPLAY WINDOW _ 2 SECTION THRU ENTRY _ 1 E A5 .1 ...........4._____ OF ROLLING GRILLE 5/8" CLEAR TEMPERED GLAZING 11 GL-1 1/2" 'L DISPLAY 2"X4" HIGH STAINLESS STEEL GLAZING SILL SECURED TO CONCRETE SUBFLOOR ...„„.,,,,, %.,„4„,,,,,,, ; r;.r.r: ,,:::::;:: :r: WITH CLEAR NON-YELLOWING SILICONE.„,,.,:. ___„.,..._ �:+r;:::. ,fff::yir:;:i::%iii' ::;ff:, .;f,,-. f ., fif :.f ..f..rrr :r .rfl:? fJ. NTS ::iii<�����~���� fr. i?fv::::::::ii::: ::r.':::-iiiii:r::::is iii:. ::::::::.......�.-.-..,..... iii,%!i! -AIM :11(i1 /1!!Ir11/11/1;11/11! f•�` F.is f'ii .f!: :i!? :.fib iii:%i::ii:..-. iii :•.f f': r.f{,'fiir f: +r'f�r �ri :f. f., ii%f: iF•:%?ii:isii;:;:jiy:}`:?:ii?iij:::i::• ::_ -___ •::i::f v::v:r TYP. BUTT JOINT a G IN IIIIIIEW .ii,ii:?.i:.i:. LAZ G ii if:%%:%iiii iii•;%%S:-i;+:is?•i:•ir; .r:fr..... J.•; 18 v.rr: %1:f•:•F4:. / iv. F i'i%? :S'f{:!iii%::� `::�:%%��%ii?:.i:.:{,r:. / .% i i.ii -iiiii : ii is%:%(;:<ii%ri?i:+:' :,.rf TYP. ::i'.i:.:<... 90 DEGREE ANGLE CONDITION r::.rrr :iii'%ii i:.';:i:�::i% F- rfvff. • i v %'%i iii .::f:-i'frr �:ifi -i%ii iiiiiii::::r; r.Ji....... ,•••••:;.%iii,•••r;: �J- J✓r iif:ii:Y•iiiiy{:}. -::v::•v.• is... 1 2 CLEAR TEMPERED NG / UNE OF BASE BELOW 'Fin:fF :::.::: 'r.-ii%='�. In \\\\ >ir'+fii: !%i"/fir ..Y:+::.`•i:Y,.i?;:is:i:�•::: ifv:f••v. �iif::.....f•:r iii,: :f.!-::::Li:•:::?%:::iiii•-:• ry'•i:+v.r :iil%%.�i::rff. -E- -::F..!::;;:-;:--i!- --::-iii:.;:= %:f. ..f:r. r..,.i:r._.r... s r::{...,,rDISPIAY GL-2 :-isjhi::::ih:?:,Y.:i::i.%.i.-.:-..:iiii?i:%%-+ I O f.r i!r. ?iii:%i:%i <i:;:•i.'.i�:%i:.:::c:::!;:..'!:i:::<<ii::i:._:?::::::::%=i :::::r::':ii::Y$;i::% is%ii%• FRAME AROUND r:::l•:l.•i:iiiii:•:?•iiiii::?:F:iii:iii:%:l!i:::%i:!::::' iii%i:%i:F i'• :. .. : .. i%%i i'�!%i!:%:?ii:•'::i:�Y.i:::i::i,+.;:?::i::ii:%::%%::ii%:ii:iii:% ..rf 4:-:?L:•iiii r. .i;.•ii..i- .:.................:... .....:..._........... US220 .:.:..:............:... RED ACRYLIC H&M • r% . 'i :<i. %i,F;iii:Ci:;i ;f%ii iiii i'.r.r... :.1::rr.r.:•-i::?•:. ........... .•.r...,........ !•i:�::.::::viY.i.:ii:?:-iiiiJ :i!!?-is?-ii: ../r.-.r x.:.r.r.r.. ..r:.. ::-, f:,.:.:.::r.::.,.,?.::<::r.;'.i'.:::ii:.i.::. 2"X4 HIGH STAINLESS ii%%i}'FiF G SS STEEL GLAZING .-.•rfrl:.-::!!•i':•i:?rir.'r.%??!vi:•i:%F.!.... ..:r. mango:'r:::::v::+ ::.�:.ter:: <:::>:> LETTERS TO BE � .,..:::...,:.ii:.i:.:i:.iir r:,.. :iiiiiii;:!.;i;:!.i�!!.i .f.. :.{r rf ..L 1.1.. ::{-',iii:��:::jrii:r: +' using b: »>i%%`-%;::<:: ::<<:: :>>::>::>:>:-:::.: <>> SILL SECURED TO CONCRETE SUBFLOOR .::::.:::'::..:':::: WASHINGTON SQUARE :.�:::.r::. ......... !::i'?!.ii: .:?.;.::::---`-'- ?:.,: .,: :::r.:,.i; ..f;rfr ...r. .....,..: ...:+ BRUSHED STAINLESS — :%%.'•;% -%.fn:->:F:ii:?.:.:-y: -.� ?.::: .:.�::. ...?:{!f•�ff� •%i:::ir::.,!y{rF;i�?.;F. ' — ":.,;: ,; .. ..: ,:; � �� / WITH CLEAR NON YELLOWING SILICONE .ii-::rr .,.:: .:' :<::<: �'-: .. ,. <,> STEEL � _ I� ri,. JOINTS FACE OF PLATFORM ,iii :::r:� .W. WASHINGTON SQUARE !.�.i:�:i::r.:. HINT N ----'- :::: 9585 S � G O SQU f 0, *' . ,:a:::-,.,i, i RED AC H 1 +F;rr:?;:%<Si:: BELOW f UTTERS SUITE H08 1 Aer r,.r f: rl Aillip .F r•:.. r:l .::� TYP. B 0 MAL.1. NT GLAZING " f.r. ii il.4ii-i .f. ?i.r�r. i;.G/.:.:jai%•r:::. �r����� PORTLAND OR 97 23 {,:f :i:,,f:i:: 2 :i ::::is :..::. ,..:,•. ••:.: f::< :;:;.:::>;:: GYP. BD. OVER 5 8 r,. 58 .• ..�.� : :::�:::i iii:?` ,... . %<< :�.<:<:>� ,.f ,::,,,.,if :,,,. :, :,iii: ? i.?,..„ ,,,: :::,,.:iri GLAS ► - ONDITIQN .,:,,,,,o::::.. 4,,,,,:.,:-i:;: •:,::: ••...,••,:::::.,„„,< : : %; PLYWOOD OVER 3 5 8 / r... {%.''Fri'!%<:<>. , .:::::.?rri:!. �y;�r �,,� � .iiii%ii ::?.:: CLASS. RED ;; :: i :i -<f ; : METAL STUD FRAMING r.:ii ``::;1::. ><%:;<:%i:%i TIGHT JOINT WITH NON-YELLOWING•`'"`' SILICONE DISPLAY AREA PT-2 `11 DISPLAY " 5/8 GYP. BD. OVER STAINLESS STEEL PANEL " 1" BRUSHED STAINLESS �, 2"X4 HIGH STAINLESS STEEL GLAZING » METAL STUD FRAMING WITH ADHESIVE OVER 5/8 SIDE 1/8" SILL SECURED TO CONCRETE SURF NOOER < 5/8 CLEAR TEMPERED FRT PLYWOOD OVER MIL. STEEL TUBE TO SUPPORT WITH CLEAR NON-YELLOWING SILICONE GLAZING STUD FRAMING AND CONCEAL POWER FEED JOINTS II' GL-1 SS-1 SIGNAGE TO BE SUBMITTED UNDER SEPERATE ' 'MIT Ail 5/8" CLEAR TEMPERED GLAZING i II GL-1 SIGNAGE PROVIDED BY H&M, G.C. TO REC 4 WRITTEN APPROVAL 7 Ar� ► LEASE UNE > G.C. TO PROVIDE POWER, SUPPORT FROM LANDLORD :EFORE PROCEDING ENTRY AND INSTALLATION OF SIGNAGE, ALL WMTH INSTALLATION ` SIGNAGE. NO GC TO ALIGN STAINLESS STEEL )e. EEY SIGNAGE SHALL BEAR A UL LABEL SIGNAGE SHAD. a 3 E MORE THAN GLASS END CONDITION MALL PANEL WITH CENTER UNE OF GLASS. CONCEALED FROM PUBLIC VIEW. 6" BEYOND LEASE UNE G.C. TO SIGN TO BE WIRED TO TIME-CLOCK. COORDINATE. , 4 A �' = 1-0" 3/4" = 1-Or' 3'=?-Q" 11/2'=�-0" ditltre I� ;��ROLLING GRILLE HEAD DETAIL 12 XT. ILLUM. WALL MTD. SIGN (80 CONNECTION GLASS DETAIL 6 GLAZING DETAIL 3 \, 1, ,- No..; \is NEArk en -4\r • < (E) MALL BULKHEAD. SHOWN HATCHED `-3 1 1 5/8" GYP. BD. OVER METAL AT.AIIEA ' STUD FRAMING 14'-0" A.F.F. (V.I.F.) i•A „„:;;St 6" MAX STEEL FASTENER FOR STRUCTURAL ATTACHMENT - 1/8 I T.O. STOREFRONT FACE OF PLATFORM ciip ll'h \\.--, \- :1, VERIFY NECESSARY LENGTH AND TYPE IN FIELD OF o . fr, i BELOW LENGTH TO ACCOMODATE 1-1 2" STANDOFF). %%f%:::i> ff..r.. �::v:•Fv !v::::: ??fi1,.i:�;iY?fr','/,'' fmow:::::::::::::::::::: :•:::i=is-ii'-is-i?i' { �r . 1 2 CLEAR TEMPERED fY: r F... .i!i iii• ...... ... if r::n:::•:iii:�iiii: :r,,rr:!,?i.?:<:: STARPHIRE DOOR, :,r,,,,.,.,.. STAR E GLASS INSTAL FRT W0. BLOCKING AS REQUIRED. :'.i:.i:<>i::!i.%<. i:.i;:-i:<:i<>:iii::i::::i N A .. :<i::..i: r. FRAME AROU D MOUNTED ON T.O. :j %%ii!'%i-ii %':i: -i`%%i.....,%%%ii'? iiw..:?•ii: <:f <:%;:....!,... RED ACRYLIC H&M ; ::f<%:i:i: PLATFORM, SEE DETAIL fi+ :ri%::i is<:::i::i:::' 'ifi{jii iii -friii '•. ii%fr. LETTERS TO � :....:: ?:. :. .iii. :l.f.. '. :::::•. ! ::::. :iii% {if<:: fir....,. 11 A FRAME AROUND RED ri.::! ;,,..:,. iiiiJ:...J;: r��:; RUSH /..fr:. is%i/. F+ B BRUSHED NESTED MIL STUD BEAM fi... - ,, ., ., .,'- is rrr n"• •:••:.. A CRYUC H&W S LETTER 4 r..J a.r...r STAINLESS STEEL G:f.f.f {r :ii i.:•:: FG:%'%:':{f{frr:•:::..r;� �� -i":3:�.. :rr.%i.... r..f ri,.:..:.::.:..r:, f �. .:. :,fii!.r. '<:<:>:<:<>;::>� SEE STRUCTURAL DRAWINGS : ...�.. .rrr TO BE BRUSHED ?%i�:::. :.�� :%:: i:•ii::i.:: :: ::is%>::>>;:<: :::/r:?ti!?4i'4i'r'-ii if-i iiii:!%ii'i`:4:.... .�.�:::. -- .. ............ RED ACRYI.0 H&M ..,..,. <:i•>:~��%:::•r:r•:fri-::::: s_:% :;>:ii :,.� >ri»:ii•>,::%»ii`:.r:•+:!%<:~• ::ter-rf:-:+r:•:• �:�f ,r:'t%.... ::Sru.....{/+fr ... ...:f'3'%:%%•i/r•..f.frr r `y''::yy<;'•,'-r; STAINLESS STEEL f. o .if.•'••� •rr. r.rf•.r? ENTRY DISPLAY AREA l i r{??l iii:%Si. fw- ?./fi..r +.•'2{ r:F.?:%r•i:+•r��if r i i'%F:811062e'��� r r. rf f LETTERS ri:•{{ r{.f/.l�/r:{:/.r f.. r.r r t:i;%»is%i:%i:%;:%i i r.O r:....,r:.::GF,: ..,y.:y- ,..„...,,,,•......„,i:;• .,i:+?+•F::ii ':•i%i'ir.. yf....;rrif:•/....`•:':?•:.r .. .r�.::x f.rr:r.... r.F...:. MO rfi:n..... :/./.. f.. ................ •;i:-;:-;:!•;:-i:-is-;:-i:• •:::.:. :�::�: :-:;:-;:-;:-is-;:-: GRIND & i!:- %,•,!iii!-iiz::` some:::-; /,c :!:• g -...'.•.• ,. ,• .. `ii::!.::..:>,:ri::'� WALL MOUNTED HINGE WftESN DS BRUSHED fl`r>F i ,,,%...f,:,i SEE OAR SCHEDULE STAINLESS STEEL PAN WITH EL S STEEL TUBE .; !.,?: <:;: ::,..,,<'��-is- << .<r..ff•' 'F•ii is?r}i:!:?4: fi%i:ir :..rf �r:r.. ,!: r - �HESNE OVER 5 8 FRT firlr.., :i r..!::.,::.: Dennis Heath Architect :r:i-r:..F .F..,r r.......rf:�r�`� <�< ;�>. r, ,;?•>,+r,.. PLYWOOD OVER MTL. STUD�' +.'••/::+ rr+:fi.!:�Fr�� .`.`�..-`::`%=i ir'%i%•I•r.,%: :y, :.f :•.r- "%'i:-ci :i:%-%"=" i it ff%% 1 •fff:: ..rfl.•`:AO ?.5,,, :---,--- li.-F.--%:`i- ±: ::.:; :rrffri%•ri:% .-' �r . .r,',i:i.. BLOCKING AS NEEDED Q P >.,> ,.i;%ii. 2470 Mariner S care Lao < LED STRIP .+r �i :• rte;:. ;i :. ,•i:.:. `ffJ. i"fi `%::; •F:•'ii:?ty f':i:f-i f ' Fi`if-!.i-:fi i::„%r.+ ir:i%f'':ir�� �_ . . 1 SS-1 Alameda, CA 94501 0— ...4-Y:-,:-,i; fffjr o -- ,�' 111111111•4121111111111111111111•11111111111111/401■11 �• A ROWNG GRILLE i!I IA ::::::_.:::„::::-.::::,,,:rii.:..:: < INTERNALLY ILLUMINTATED H&M SIGN, SEE SHOP 1" BRUSHED -- ---- ; 12-0 !II ti STAINLESS STEEL '' A.F.F. 1 1 11 1 I 1 fiA SUPPORT I DRAWINGS TUBE TO SUPPORT a T.O. STOREFRONT WINDOW -CENTERLINE OF GRILLE Iii itt AND CONCEAL POWER CURTAIN- SEE DOOR `? Drawings and Britten material appearing herein caastitute original FEED , , , SCHEDULE II a 11" and unpublished wort of the Architect and nag not be duplicated, 3/8" FLEXIBLE CONDUIT TO ELEC. PANEL AS REQUIRED " 1�� used or disclosed without written consent of the Architect ME Mii 0(PROVIDED BY ELEC. CONTRACTOR) � 1� .I, II (c D H ARCHITECTS- 2010 - 5/8" GYP. BD. OVER _ Iii ALUM. GLAZING CHANNEL SECURE - Ili- - : y � , _ 3/4" P L Y W O O D OVER , 1'"'�"� -- 1' GLAZING W/ BLACK STRUCTURAL A » a A Q C �, J-BOX (PROVIDED BY ELEC. CON-FACTOR) SIGNAGE TO BE SUBMITTED UNDER SEPERATE PERMIT METAL STUD FRAMING- - ►) SILICONE LEASE UNE 5/8 CLEAR TEMPERED PT-2 _ • _ GLAZING No Dote Issue SIGNAGE PROVIDED BY H&M. G.C. TO RECEIVE WRITTEN APPROVAL 10» STAINLESS STEEL PANEL GL-1 G.C. TO PROVIDE POWER, SUPPORT FROM LANDLORD BEFORE PROCEDING / f < 5/8 CLEAR TEMPERED GLAZING yy� ADHESIVE OVER 5/8" 05/28/10 100% SET AND INSTALLATION OF SIGNAGE, ALL WITH INSTALLATION OF SIGNAGE. NO GL-1 FRT PLYWOOD OVER MTL. 2"X4" HIGH STAINLESS STEEL 05/28/10 VT PACKAGE SIDE (E) STRUCTURE, VERIFY IN FIELD SIGNAGE SHALL BEAR A UL LABEL SIGNAGE SHALL. EXTEND MORE THAN DISPLAY GLAZING SILL SECURED TO CONCEALED FROM PUBUC VIEW. 6" BEYOND LEASE UNE - G.C. TO , C STUD FRAMING CONCRETE SUBFLOOR WITH 07/02/10 1 00% COMPLETE SET TRACK HEAD AS SCHEDULED. WITH CLEAR NON-YELLOWING SIGN TO BE WIRED TO TIME-CLOCK. COORDINATE. * REFER TO RCP SS-1 SILICONE JOINTS 07/28/10 LANDLORD SET WALL MOUNTED SIGN DETAIL I 1• m " 11 INT. ILLUM. WALL MTD. SIGN (48") 3/4" _ 10" 8 BULKHEAD I GLAZING HEAD DETAIL 3"=1-0" 5 PORTAL DETAIL I 1 1/2°: 1-O 2 08/13/10 PERMIT/BID SET +77-- " TEMPERED GLAZING 5 8 CLEAR 5 8" GYP. BD. OVER DISPLAY / „ ti r f _ 1" BRUSHED AINLESS WINDOW GL-1 5/8" PLYWOOD OVER ;f':,' `r,--'`,.```-.„ STEEL TU:- TO » » METAL STUD FRAMING ,II SUPPQ'1 AND CONCEAL < PLYWOOD OVERALSSTUD PT-2 > II 6" PO FEED FRAMING I .I / FRAME AROUND .ME AROUND 3/4" MDF OVER 1/e PLYWOOD ' 5/8" GYP, B0. OVER r .,II_ f{ ` ' RED ACRYLIC H&M RED ACRYLIC H&M OVER MTL. STUDS FRAMING LETTERS TO BE - LETTERS TO BE 5/8 PLYWOOD OVER BRUSHED STAINLESS BRUSHED STAINLESS FLOOR MOUNTED DISPLAY OUTLET. 7 8" HAT CHANNEL II r'``'` STEEL STEEL SEE ELECTRICAL DRAWINGS PT-2 I , � ++� �: if .,; > ; .'a GLASS SHOE MU WON .i .5 frf:; jr PLANKS TO BE CUT AND LAY IN BY I '` Ff' f FF ''�. _ . '�F f; r " " GC. PRODUCT PROVIDED BY H&M- 02- - -� " -41104P4, ,„ '{ .f �, 00 4” ALIGN A 7\ 1/4" ALUM. •UNTING PLATE , •l: "' '� V ADJACENT TENANT FINISH MNTD. TO OFFTT AND BLOCKING F, ;,` � j :: , �, CUSTOM .090 ALUM. WITH 1 ' QUATE HARDWARE. <: I 1--- RED ACRYLIC H&M •ANGLE WELDED TO WELD (TYP.) UETTERS i .'V , / �/ J� I EXISTING NEUTRAL PIER 1/4" ALUM, PLATE. SHOWN HATCHED...0( '_w --= - -• - COUNTERSUNK • �� IP _ �` i� // EXISTING 3/4" REVEAL [EI U 11 P i j i // // Project No. 44122 SCREW STAINLESS STEEL PANEL WITH ADHESIVE BRUSHED ALUMINUM 2'- BRUSHED ALUMINUM 1 OVER 5/8" FRT PLYWOOD PANEL / PANEL I I 1"X1"1/8" SQ. ALUM. 2 PIECE DECORATIVE ,J `'- D I S P L A Y A R E A I SS-1 S c a l e AS NOTED TUBE WELDED TO 1/4" .090 ALUM. COVER - _ ALUM. PLATE FROM : . :; . UNE BOTTOM AND TOP. E' _� 5/8" GYP. BD. O V E R 7/8" H A T CHANNEL D r o w n B y: DM/AN SIDE FRONT `. �'^ , OVER BUILT-UP BOX COLUMN 5/8" CLEAR TEMPERED GLAZING g 1111111 171-2 II n R:\HM\Projects\2010_Projects\44122 Washington Sq\Drawings\CA\US220J152.d '1 U I E Q SIGNAGE TO BE SUBMITTED UNDER SEPERATE • .'MIT - I - GL-1 SIGNAGE PROVIDED BY H&M, G.C. TO REC ■∎ WRITTEN APPROVAL LT-1 < 2"X4" HIGH STAINLESS STEEL GLAZING Drawing N o. Q G.C. TO PROVIDE POWER, SUPPORT FROM LANDLOR► :EFORE PROCEDING SILL SECURED TO CONCRETE SUBFLOOR STOREFRONT �; AND INSTALLATION OF SIGNAGE, ALL WITH INSTALLATION ` SIGNAGE. NO BLOCKING AS REQUIRED WITH WITH CLEAR NON-YELLOWING SIGNAGE SHALL BEAR A UL LABEL SIGNAGE SHALL EXTE'` MORE THAN 6C SILICONE JOINTS & SIGNAGE DETAILS MALI. CONCEALED FROM PUBUC VIEW. 6" BEYOND LEASE LINE G.C. TO AA5.2 SIGN TO BE WIRED TO TIME CLOCK. COORDINATE. T O 3"4_-Or 3/4'=1-0' 6"0-0" 4.,-2 V2 = 1-0• i LLUMINATED PENDANT SIGN DETAIL 1 ► NT. ILLUMINATED BLADE SIGN GLAZING SHOE / W/OUTLET 4 NEUTRAL PIER DETAIL__ A5.2 ti,-- REFER TO FOR STUD SIZE MATRIX'"1":"‘ 1\ UMITINO HEIGHTS FOR INTEL METAL STUD PAR1111ONS �` / 9A 9A 9A ... ?= '.-�lLiIL•1k= .111■ • ; AAllaif. I =1 :- 1 tit . 1 .•1.40 CONT 18 GA. DEEP LEG DEFLECTION .k•.i.-_.__�* ..alilltki:: .tile•. I =A..,�_ / ►■C . I ..1.a TRACK (2" MIN. DEEP LEGS) Q ALL SEISMIC DESIGN CATEGORIES, c CONNECT DEFLECTION TRACK TO (E) B.O. (E) JOIST \-- B.O. (E`) JOIST B.O. {E) JOIST STUD FLANGE STUD STUD MAXIMUM CONCRETE FILLED MTL DECK FLUTES ° » 16 GA TYP - D�ESIONA WIDTH G AUIX SPAC NG MONT W/ (1) P.A.F. . . çSLOTTED /� 16 OC 0118 4 3625162-33 3 5/8" 1 8" " ' " I R ACK UNDERSIDE OF {E) SLAB AT 24 O.C. MAX. CONTINUOUS FIRE RETARDANT (SLP-TRK OR EQ.) 4 J 362S126-43 3 5/8" 1 5/8" 18 16" 19'-0' FASTENER (P.A.F.) W/ 1" EMBEDMENT CONT. TRACK WITH (1) #10 AND 12 FROM EA. END SEALANT AT TOP AND BOTTOM SCREW IN EACH FLANGE OF OF PARTITION, BOTH SIDES 362S162-54 3 5/8" 1 5/8" 16 16" 20'-6" (2) LAYERS 5/8 TYPE X GYP. BD. AT 362S162-33 6' 1 5/8" 20 16" 26'-6" EACH STUD I < (E) 6 MTL " STUDS 1 fi BOTH SIDES OF 3-5/8" METAL STUD FRAMING > Milt < 600S162-43 6 1 5/8 18 16 28"-6" O.C. BY LANDLORD . US220 600S162-54 6" 1 5/8" 16 16" 30'-O" — SEE RCP = _ _ — _ — = SEE R.C.P. _ — = SEE RCP — — _ B NON RATED B.O. CEIUNG I < GYP. BD. BY B.O. CEIUNG WHERE OCCURS B.O. CEIUNG WASHINGTON SQUARE OTHERS CONT. METAL BRIDGING NOTES: 5/8" TYPE 'x" GYP. SYSTEM SEE 9585 S.W. WASHINGTON SQUARE BD. BY G.C. 1. DSIGN BASED ON ALLOWABLE DE ;;J ;. A6.0 (1) LAYERS 5 8" TYPE > > ELECTION OF L/200. (TENANT SIDE ONLY) > R-11 SOUND ATTENUATION INSULATION - �� O / SUITE H08 _ "X GYP. BD. AT BOTH PORTLAND, OR 97223 " . BATT INSULATION, WHEN OCCURS > " 2. DESIGN BASED ON Fy = 33 KSI FOR 3 5/8 & 6 STUDS LESS THAN 16 GAUGE. o �,t !M. IEdBdI SIDES OVER 3-5/8 Fy = 50 KSI FOR 3 5/8", 16 GAUGE & 6", 16 GAUGE STUDS. SEALANT W/ BACKER ROD 16 GAS TYP MTL TRACK. ANCHOR TO FLOOR SLAB METAL STUD FRAMING CLASS; RED 1ST LAYER TYPE "X GYP. BD. , ' LEASE UNE ill' AT 24 O.C. MAX AND 2 FROM EITHER END W/ 3. PROVIDE HORIZONTAL BRIDGING 0 4'-0" 0.C• MAX PER MANUFACTURER'S RECOMMENDATIONS. FOR 1 HR. RATED WALL �� HILTI DS SERIES POWDER ACTUATED PINS. r I � COMPLY W/ ICBO #1632 l 4. DESIGN BASED ON MINIMUM 5 PSF LATERAL LOAD, OR LATERAL 2ND LAYER TYPE "X' GYP. BD. ;,fib _ 7 TERAL SEISMIC LOAD, WHICHEVER CONTROLS. FOR 2 HR. RATED WALL FINISH FLOOR (E) MTh. TRACK l, BASE AND FINISH FLOOR 1 \ 1 SEALANT BASE AND FINISH FLOOR 5. TABLE IS VAUD FOR UP TO (3) LAYERS OF GYPSUM BOARD. 1" DEFLECTION SPACE (DO NOT CONNECT DEFLECTION TRACK (E) FLOOR SLAB 1 (E) FLOOR SLAB (E) FLOOR FASTEN RUNNER, STUDS, OR TO (E) CONCRETE FILLED " " I SLAB MIL DECK FLUTES W/ (1) +0.-0- +0.-0- +0.-0- GYP. BD. TO COMP. TRACK) ( — — — — PA.F. 16" O.C. STUD SIZE MATRIX FOR ALL SEISMIC DESIGN CATEGORIES S ( FINISH FLOOR - FINISH FLOOR - FINISH FLOOR - SALES PARTITION WITH OR WITHOUT SHELVING ATTACHED SAFlNG MATERIAL 0°118' 0 HILTI, X-DW - NON-SALES P WITHOUT BHELVIE� ATTACHED FASTEN WTI- STUD TO RUNNER I POWDER ACTWATEQ FASTENER RUNNER TRACK (P.A.F.) W/ 1" EMBEDMENT A i H R OR 2 RATE D = AS SHOWN ON PARTITION LEGEND B = AS SHOWN ON PARTITION LEGEND = AS SHOWN ON PARTITION LEGEND , ` �� # 1011 ASSEMBLY PER U.L NO U419 ASSEMBLY PER U.L NO U419 I ASSEMBLY PER U.L NO U419 �, I1 N.T.S. 3•=t-0" 1 1/2'=f-tx' - i� f �`'' �.>A STUD MATRIX _ 12 NON-RATED DEFLECTION TRACK 9 RATED WALL PARTITION DETAILS (WALL TYPE B AND J) 3 ) P1= r� rn ALAMEDA CA ; OF a ALL WALL CONS7RU O'I MUST BE U.S. OF STRUCTURE 'f i DOUBLE STUD 0 SIDES C. CMI UST � -- DO BI..E S GS SUPPORTED BY THE TOP CHORD OF METAL STUDS. FOR GA. AND SPACING, STRUCTURAL JOISTS. NOTHING � REFER TO 12/A6.0 FOR SHEATHING �,' TO BE ATTACHED TO THE ROOF DECK c • REFER TO CONSTRUCTION PLANS. > UNE OF CEIUNG, WHERE �, OCCURS V 3 5/8 20 GA STUD \/\ W/ 4 #8 TIES TO " " 1/2" <> UNDERSIDE OF SLAB. 1-1/2" X 3 X 16 GA. CHANNEL WIDTH, TYP. - ATTACH AT EVERY STUD E — I NIL (4) #8 TEK SCREWS WITH (4) 5/8" #5-12 SCREWS OR I 1 Pr BACKING PLATE 3/4" WELDS IN (3) PLACES. 14144ki$1.°11° \ç// / 3 5/8", 20 GA STUDS DIAGONAL < �< 6" x 16 GA MTL PLANT BRACING TO STRUCTURE AT 4'-0" 0 WELDED 0 4 STUD MIN. /�� 4 STUDS 3 4" 16 GA. COLD-ROLLED t A'B c� 16" O.C. O.C. ALTERNATE DIRECTION} / " 1111111111 Dennis Heath, Architect _.,i MIN. _ CHANNEL LOCATE AT 4 0/I (4) 18 TEK SCREWS 0.C. HORIZONTALLY, OR AS 2 410 Mariner Square Loop REQUIRED B Y L O C A L CODE. , Alameda, C A 94501 3 5/8" 20 GA. STD LEG TRACK 4%. 4 C) 4111111 411111L DOUBLE STUD 0 SIDES A45° MAX. OF OPENINGS 3/8" LONG `��,��,> Drnwings and written material appearing herein constitute original 1/16" TNG and unpublished work of the Architect and may not be duplicated, ALL FLANGES OF BACKING p 1 P PLATE TO 16 GA. STUD " used or disclosed without written consent of the Architect <-4-100> ®DH ARCHITECTS- 2010 44,.. 16 GA. SCREW STUDS < WALL FINISH VARIES D Q C WHERE BACKING PLATES (SHOWN DASHED) No . D a t e I s s u e OCCUR 4 BACKING PLATE 6" x 1 • > < SHEATHING AS DETAILED STORES IN SEISMIC ZONES 3 & 4 ONLY 05/28/10 100% SET 1/4- 16 GA. TRACK " SEE RCP \ PROVIDE CUP ANGLE(S) +-5'-0" A.F.F. AT 05/28/10 VT PACKAGE NOTCHED AROUND AND �� 1 LONG 1/16 GROOVE , /� LESS, " 07/02/10 100% COMPLETE SET B.O. CEIUNG v WALLS 10'-0' HIGH OR LESS AND EVERY WELDED TO STUDS WELD TYP. 0 WEB OF 4'-0" AT WALLS GREATER THAN 10-0 OR 07/28/10 LANDLORD SET BRACING PLATE TO STUD AS REQUIRED BY LOCAL CODES. BLOCKING PLATE TYPE 'B" NOT USED - 8 PARTITION BRACING DETAIL 3�r-01 5 METAL BRIDGING DETAIL 1�2':r-cr 08/13/10 PERMIT/BID SET 1 2 (-9-1-3 NOTE: REFER TO AM FOR STUD SIZE MATRIX TYP. 20 GA. MIN. SCREW DOUBLE STUD SIDES (çs\ 6 OMIT GYP. BD. ON NOT EXPOSED SIDE , OF OPENINGS STUDS c • ��%.1- (98") 98 ("9-E; (-9-B*. '�`° ► B.O. (E) JOIST ( J ( } A�j A6,0 Afi.O Afi.O MD Pill" 20 GA TYP 3 5/8" DEEP LEG 0 MTL TRACK ANCHOR TO ''"' —''"'` T""` "'' ''"� "'" ""` � � 0 UNDERSIDE OF (E) SLAB AT 24" 20 GA. , O.C. MAX. AND 12" FROM EA. `"� CONT. METAL BRIDGING END OR BRACE AS DETAILED / SYSTEM, TYP. SEE BACKING PLATE 6" x 18 o A6.0�SIM. .,,,_ �,._ •.-. .,,.... GA. ATTACHED TO STUDS o (3) #8 F.H.S.D.S. METAL BACKING AT PROCESSING W/ (3) #8 F.H.S.D.S. AREA & TOILETROOM. SEE A.,6;9' 0 10/A6.0 E.. ..: 1' LONG 1/16 GROOVE SEE R.C.P. ilI/i■ WELD TYP. O WEB OF BRACING PLATE TO STUD B.O. CEIUNG WHERE OCCURS 5/8" GYP. BD. FILLER 5/8" GYP. BD. FILLER rl.i . r. BLOCKING PLATE TYPE "A" i G.C. TO V.I.F. FOR .�,. ,... •� 8'-0" A.F.F. — - Project No. 44122 BLOCKING LOCATION PER T.O. WALL SHELVING WALL CHANNELS SI{AFT _—r`i— �--� . . - S c a l e AS NOTED UNE OF CEIUNG UNE OF CEIUNG © LINE OF CEIUNG UNE OF CEIUNG c UNE OF CEIUNG UNE OF CEIUNG ____„.._v\______ 1. TYPE "A" BACKING FOR MISC. ITEMS, IE. SURFACE MTD. MIRRORS, WASTE RECEPTACLES, TOWEL " ::.<; " " co 5/8" GYP. BD. OVER 5/8" m 5/8 GYP. BD. OVER MTL -\ 5 8 GYP. BD. OVER 5 8 FRT 5/8 GYP. BD. OVER 5/8 " " DISPENSERS, ETC. / / o FRT PLYWOOD OVER 2 1 2 0 5 8 GYP. BD. 5 8 TYPE 'X GYP. STUD FRAMING 5/8 W.R. GYP. PLYWOOD OVER MTL STUD r= FRT PLYWOOD STRIPS OVER / F- MAXIMUM " / D r a w n B y: DM/AN MAXIMUM WEIGHT - 50 LBS. _ MTL STUD FRAMING ON OVER 7/8 HAT BD. OVER C-H STUD " BD. 0 WET AREAS -- > FRAMING > °- MIL STUD FRAMING. G.C. TO a' AND 1" TYPE "X" GYP. 2. TYPE "B BACKING PLATES FOR UPPER WALL HUNG CABINETS (UP TO 2 SHELVES) BASE CABINETS, FULL r BOTH SIDES. OMIT 5/8 FRT • » = CHANNEL AT 16" O.C. E HEIGHT CABINETS, HANDRAILS, GUARDRAILS, GRAB BARS, WALL HUNG EQUIPMENT, ETC. R-11 SOUND ATTENUATION 20 GA STD. LEG MTL TRACK W/ VERIFY REQ'D LOCATION OF PLYWOOD AT WALLS WHERE 5/8 GYP. BD' OVER 5/8 OVER MTL STUD BD. PER UL #U469 > � STRIPS FOR FIXTURE FRT PLYWOOD OVER MTL � # MAXIMUM WEIGHT - 100 LBS./FT. INSULATION (REQ'D 0 TOILET ROOM HILTI X-DNI 32 P8S15 3'-O' 9 DOORS ARE LOCATED. SEE FRAMING c ,.. INSTALLATION > STUD FRAMING. ,_ >:: 3. SEE TYPICAL WALL FRAMING FOR GAUGE OF STUDS, VERIFY LENGTH, HEIGHT, LOCATION OF BACKING PLATE, WALLS & OFFICES, TYP• AU. WALL TYPES > O.C. MAX AND 12 FROM EITHER DETAIL 12/ AO 3 a R:\HM\Projects\2010_Projects\44122 Washington sq\Drawings\CD\US220JA60.d AND NUMBER. BASE & FLOORING AS SCHEDULED, • r END p -1 p p p in 4. REQ'D WITH ACCESSORY MANUFACTURERS. USE #12 SELF TAPPING SHEET METAL SCREWS WHEN NP• AU_ WALL TYPES t° > (E) FLOOR SLAB I I I I I I 1 I ATTACHING ITEMS TO BAKING PLATE. Drawing N o. +0-0 ° 5. WALL STUD FLANGES ARE CONTINUOUS AT BACKING PLATE. I c J — — — -� — — — L - — — — — - — I — I — — — 1- I I PARTITION DETAILS ° FINISH FLOOR H E F G V2"=1-a' 11/2"=1-0�" ..,.. METAL FRAMING BACKING DETAILS _ 10 WALL PARTITION DETAILS (WALL TYPE D - K) _ i A6 .O + -+. - I I 362S162-33 0 16" O.C. - 4` ATTACH TO STRUCTURE ABOVE I I I NOTE: 3625162-33 0 16" DIAGONAL I I I 3" GAP TO REMAIN GC. TO SPRAY ALL NOTE. I VISIBLE INSTALLATIONS BRACE 0 48" O.C. GC. TO SPRAY ALL VISIBLE - - - - I IN BLACK INSTALLATIONS IN BLACK A • MTL. STUD FRAMING, ' 3 5/8" GYP. BD. TYP. AT END '� / UGHT FIXTURE AS SCHEDULED. I OVER 2-1/2" MTL CONDTf�N To BE ATTACHED TO PROFILE . STAINLESS STEEL PANEL ' -`' W ADHESIVE OVER STUD FRAMING TO WITH CLIPS SUPPLIED BY EE RCP APLYWOOD OVER MTL. BE PAINTED :. LIGHTING MANUFACTURER � �.OGEIUNG� FRAMING > .'... ------_-_--__ -- - - - - - _ • MTL STUD FRAMING, GC TO GONER INSTALL PAINTED -5/8" GYP. BD. CEILING. 4 EXTEND WALL AS TYP. AT END • I -----7: 4i111041111111 GYP. BD. AT THIS LOCATION ONLY PAINT PER ,� • INDICATED. FINISHES TO CONDITION TYP. ommmmmmmmml US220 IF VISIBLE FROM AREAS ABOVE FINISH SCHEDULE FRT BLOCKING AS MATCH WALL BELOW >• 1'-4' REQUIRED • 6" 2" HOLD STUD WASHINGTON SQUARE • • � 111111. SEE RCP I _ ,- I - ., � ^: SEE RCP -" SEE RCP 7 B.O. DISPLAY CEILING -� B.O. CEILING• SW WASHINGTON I' Z e.o. SALES $ 9585 S AS GTON SQUARE _ �' , 6 1 f2= 6" CEILING SUITE H08 • `V 0O ALUM. GLAZING CHANNEL " / HOLD / HOLD ' / PORTLAND, OR 97223 ..r _r -MAINTAIN fi MIN. GAP FROM 5/8 GYP. BD. CEILING. G.C. i, s .- SECURE GLAZING Wf BLACK � � PERIMETER WALL TO DROP TO PAINT PER FINISH " •ily 44\ illP11111.■ Ailh' o STRUCTURAL SILICONE _ � AINTAIN 6 MIN. GAP FROM S� CLASS. RED •�- CEILING, TYP. U.O.N.UON SCHEDULE 5 8" GYP. BD. CEILING OVER � PERIMETER WALL TO DROP B.O. RUING/ 8. CEILING, TYP. U.O.N. • • 5/8" PLYWOOD OVER MTL. ROOM CEILING STUD FRAMING. REFER TO RCP HOLD \ 5/8 GYP. BD. OVER MTL SEE RCP 5/8" GYP, BD. OVER I REFER TO FINISH PLAN T.O. BULKHEAD MTL STUD REFER TO " • FOR FINISHES FINISH PLAN > hTOREFER TO RCP SEE RC STOREFRONT GLAZING BULK �► REFER T.O. HEADER TO ALIGN FOR PAINT TRANSITION. p PAINTED BU WITH T.O. OF SEE FINISH SCHEDULE B.!. S I PENDED CEIUNG4 TO FINISH PLAN . WARDROBES, TYP. 1'-8 1/4." MIN. < UNE OF WALL BELOW LIGHT FIXTURE FROM Fl ' RE 1W. 18" SUSPENDED GYP. D. MONOPOINT HEAD AS E RCP B.O.8 HEADER/ BULKHEAD BEYOND CEILING. G.C. TO PAINT SCHEDULE. SEE RCP AND DISPLAY AREA �` - SALES AREA UNE OF WALL BELOW > / Ai SUSPENDED CEILING TYPE C PER FINISH SCHEDULE H&M CD 2:8 ELECTRICAL DRAWINGS WHEN CEILING HEIGHT IS MORE THAN 9'-8" A.F.F. REFER TO PLAN SALES AREA Iiir }LEADED/ BULKHEAD FITTING ROOM AREA H&M CD 2:7 H&M CD 2:6 t , P":74% - LING DETAIL AT INTERIOR ENTRY CEILING DETAIL AT HEADER 3 �. y- I. • .I 11 — — tit � 1��, t IS ��AI<� SEE RCPAL 4. .,t NOTE: A C. TO SPRAY ALL VISIBLE B.O.80 CEILING �• AA-ATVlIEt�A -5/8" GYP. BD CEILING. G.C. '0 < MTL STUD FRAMING, INSTALLATIONS IN BLACK >I I MIL STUD D - ING, PAINT PER ASH SCHEDULE TYP. AT END - - - - STAINLESS STEEL PANEL � I N�DATa N D , RECESSED LIGHT TRACK 4 S -GC TO ! 3' INSTALL PAINTED WITH ADHESIVE OVER CONDITION I + , GYP. BD AT THIS LOCATION ONLY 3/4" PLYWOOD OVER MTL. I _J IF VLSI: 4 FROM AREAS ABOVE STUD FRAMING > 1'-4" o I FRT BLOCKING AS 5/8' GYP. BD. REQUIRED STUD FRAMING TO OVER 2-1/2"/2" MTL i iii a • • - - - - LIGHT FIXTURE AS SCHEDULED. BE PAINTED BLACK • • '�' "/ SEE RCP h TO BE ATTACHED TO PROFILE 1 ill&a., I KF B.O. DISPLAY CEILING WITH CUPS SUPPLIED BY GHTING MANUFACTURER 1 -8 1/4"" MI N. SEE RCP:,!, 1i- •3 ►to 3 UN UGHT Fl 4 RE FROM FIXTURE TYP. 5/8" SUSPENDED GYP. :D. ALUM. GLAZING CHANNEL SECURE GLAZING W/ BLACK ej /---- 0 I-I D e n n i s H e a t h A r c h i t e c t 1)BEYOND CEIUNG. G.C. TO PAINT STRUCTURAL SIUCONE - alk SUSPENDED CEILING ' 'E B PER FINISH SCHEDULE �_ 2 410 11 a r i n e r Square Loop • WHEN CEIUNG HEI IS 9'-O" T O 9'-8" A.F.F. H&M CD 2:13 5/8" GYP. BD. CEIUNG OVER 8' ____ _., .. �' Alameda, C A 94501 5/8 PLYWOOD OVER MTL. / / 1\JQ ' IN.� ® SEE RCP STUD FRAMING. REFER TO RCP HOLD A B.O. CEIUNG FOR FINISHES " 6' � 2 / cx HO / H!' a / 5 8" GYP. BD. - - - - - - - - - STOREFRONT GLAZING/ '� • • 0 J-MOLD CEIUNG. G.C. TO Drawiaga and writtee material appearing herein constitute original TRANSOM WHERE OCCURS o I ° I ° PAINT PER FINISH a 1 i unpublished work of the Architect and may not be duplicated,4C>/. a _= JL--- MONOPOINT HEAD AS `�-� A •? • = SCHEDULE used or disclosed without written consent of the Architect INF se' SCHEDULE. SEE RCP AND —MAINTAIN 6" MIN. GAP FROM PERIM I R (c D H ARCHITECTS- 2010 -- - ELECTRICAL DRAWINGS B.0 SEE CEIUNG WALL TO DROP CALLING, TYP. U.O.N. T.O. SEE PORTAL 1 RCP � REFER TO P 5/8" GYP G C 5/8' GYP. BD. O V E R MIL. STUD Q A Q C •,I, ' / PLAN / . BD. CEILING. . . 8 1 4" MIN. " 1.1 To PAINT PER FINISH FRAMING. EXTEND PAINT FINISHES TO 6" 5/8 SUSPENDED GYP. BD. SCHEDULE ,!,� 8 ABOVE GAP N0 . Date Issue FROM FIXTURE TYP. HOLD CEILING. G.C. TO PAINT DISPLAY AREA / ENTRY 5'°`!E ARE► k . ,. 05/28/10 100% SET PER FINISH SCHEDULE PAINTED PORTAL WITH UGHT FIXTURE. 0 SUSPENDED CEILING TYPE A 5/8" GYP. BD. OVER REFER TO FINISH PLAN 05/28/10 VT PACKAGE WHEN CEILING HEIGHT IS 8'-2" TO 9'-0" A.F.F. 2-1/2" MTL STUD FRAMING < LINE OF WALL BELOW 07/02/10 100% COMPLETE SET TO BE PAINTED BLACK. H&M CD 2:' H&M CD 2:11 H&` CD 2:3 07/28/10 LANDLORD SET ref-0" re-0" 08/13/10 PERMIT/BID SET SUSPENDED CEILING DETAILS 11 CEILING DETAIL AT EXTERIOR ENTRY _ — 5 FILING GAP DETAIL AT PORTAL _ ___4 — 3" GAP TO REMAIN +-t 3" GAP TO REMAIN - - - - > MTL STUD - ING, - - - > MIL STUD FRAMING, _ _ _ I-- - - - H TYP. AT � a f- - - - -I - - - - - > MTL STUD FRAMING, . TM. AT END -1 TYP. AT END (E) STRUCTURE BEAM/JOIST/TRUSS 4 COND I CONDrnON I CONDITION MECHANICALLY FASTENED I I NOTE: I NOTE: PER MFR RECOMMENDATION GC. TO SPRAY ALL ( GC. TO SPRAY ALL ANGLE BRACKET - - - - - - - - - - - INSTALLATIONS INSTALLATIONS IN BLACK " IN BLACK PT-5 1 - - - - 3" \ 3 MTL CHANNEL CUP OR " �' HANGER WIRE 5 8 GYP. BD. OVER 2-1 2 ( " _ _ _ " MTL. STUD FRAMING TO BE 5/8 GYP, BD. OVER 2-1/2 5j8 GYP. BD. OVER -1/2 MTL ; 8 GA HALER WIRE 0 48 MTL. STUD BLACK >1 GC. TO SPRAY THIS MTL STUD FRAMING TO BE STUD FRAMING TO BE PAINTED _ OC & WITHIN 6" OF END AREA AND ALL ALL PAINTED BLACK SAME COLOR AS THE WALL BELOW 4` OF CARRYING CHANNEL VISIBLE 1-1 2" CARRYING CHANNEL INSTALLATIONS IN UGHT FIXTURE AS LIGHT FIXTURE AS /, , _ I BLACK = SCHEDULED. TO BE ATTACHED SCHEDULED. TO BE ATTACHED 6" MAX 0 To PROFILE WITH CUPS = TO PROFILE WITH CUPS / OF WALLS •SPACE 24. O.C. - I - SUPPUED BY LIGHTING - SUPPLIED BY LIGHTING " FOR FIRE RATED MANUFACTURER MANUFACTURER 3 MIN. ''> CONSTRUCTION) - PROVIDE ilyzi_ 1 1" CLR 0 ABUTTING WALLS • 1/2" o o D I AND PARTITIONS idir -I,rill r ,,, , „, _i.4 err► ss� r■► r �� 11,, fl) — -- Project No 44122 1: Pr�.� III SEE RCP SEE RCP SEE RCP I SEE RCP ::.. . ....: II :.e. 'T '' ♦ B.O. CEIUNG 6” 6 1/2' A B.O. CEIUNG ' tZ B.O. GYP. BD. CEIUNG o r 6 • 6 1/2 MOLD J-MOLD 7/8" DRYWALL CHANNEL RIGHT S c a l e AS NOTE D HO a ! t 5 8" GYP. BD. CEIUNG. - " / �, HOLD J-gyp 5/8 GYP. BD. � 5/8 GYP. BD. CEIUNG. G.C. o ANGLE TO CARRY CHANNEL AND SPACED G.C. TO PAINT PER CEILING. G.C. TO • ° MAINTAIN 6" MIN. GAP FROM TO PAINT PER FINISH '- . 16" O.C. SPACE FURRING WITHIN 3" OF 101AINTAIN r MIN. GAP FINISH SCHEDULE PAINT PER FINISH cr PERIMETER W A L L T O DROP SCHEDULE W A L L S AND PROVIDE 1 CLR 0 D r a w n B y: DM/AN FROM PERIMETER WALL TO DROP U.O.N. GC TO REINFORCE CEILING SCHEDULE CEILING, TYP. U.O.N. ABUTTING WALLS AND PARTITIONS SEE RCP - E WITH FRP PLYWOOD �-\\ MAINTAIN 6" MIN. GAP FROM PERIMETER 5/8" GYP. BD. OVER MTL SEE RCP "' MTL 'L' ANGLE FASTEN TO WALL WITH P. BD. !- BLOCKING FOR �'� WALL TO DROP CEILING, TYP. U.Q.N. B.O. SOFFIT STUD REFER TO FINISH PLAN T.O. BULKHEAD CUP. FASTEN CARRY CHANNEL TO MTL, PLANS.! 'SHOWN 1 •�• FREESTANDING FRAME AS 5/8' GYP. BD. OVER MTL STUD 'L' ANGLE WITH #10-1 1/2" SHEET R:\MAProjects\2010_Projects\44122 Washington Sq\Drawings\CA\US220_161a.d SHOWN ON RCP MTL SCREWS Q a FRAMING. EXTEND PAINT FINISHES TO Lci ! !• 8" ABOVE GAP PAINTED BULKHEAD REFER < Drawing No A WARDROBE FIXTURE G.C. TO INSTALL FRY REGLET RE1/EAL ►L ES AREA TO FlNISH PLAN SAL ES AREA L FS ,a•MOLDING AROUND FIXTURE CEIUNG DETAILS N < UNE OF WALL BELOW 1 WALL FRAMES FIXTURE > < LINE OF WALL BEYOND, SHOWN DASHED cp CD 2:2 —1-4•— H&M CD 2:1 + H&M CD 2:4 H&M CD 2:4 •L -,-., EILING GAP AT FREESTANDING FIXT. lb CEILING GAP DETAIL AT WARDROBES - 7 CEILING GAP DETAIL AT BULKHEAD 3'=�-0' 4 TYP. GYP. BD. CEILING DETAIL AT END '' i A6 .la ag...' - . . / \ NOTE: LATERAL BRACING FOR SUSPENDED CEILING MUST BE PROVIDED PER ‘11111 El UBC REQUIREMENTS WHERE LOADS ARE LESS THAN 5% PER FOOT & SEE RCP NOT SUPPORTING INTERIOR PARTITIONS. gilry B.O. GYP. BD. CEILING GYP. BD. CEILING. G.C. TO • PAINT PER FINISH SCHEDULE 8-0 MAX / ,I�- 4-0 MAX FRT BLOCKING AS REQUIRED 4-0"MAX HANGER WIRE CRATED CLG 1 1/4" X 1 1/4" FULLY RECESSED LIGHT TRACK J ,,, 00 MAGI RUNNER 0 4'-0" r w O.C. 0 SEMI-RECESSED MOUNTED __- ._1111 _11.11- __.1111 X � X X 38E US220 ;INNEL 0 MAIN RUNNER 1.4). 0.c. WASHINGTON SQUARE - o X X X X Zx $585► S.W. WASHINGTON SQUARE IN • :.:,,:.: 12 GA. HANGER WIRE o SUITE HO$ • _ 4'-O" O.C. EACH WAY ' PORTLAND OR $7223 -Nk■ -B.O. GYP. BD. CO �. �►. CLASS: RED SEISMIC COMPRESSION .� GYP. BD. CEILING. G.C. TO STRUT A 12" O.C. EACH PAINT PER FINISH SCHEDULE ("4".� MAIN RUNNER WAY. SEE ' FRT BLOCKING AS REQUIRED A6.1 •,..,,� ATTACH FIXTURE HOUSING 0 EACH CORNER TO CEIUNG SYSTEM WITH SELF .i.e,, ii,• ""°°I'4 4•''4 i 1 4,II 4 4,,,,II. TAPPING MTL SCREWS AS SPECIFIED. SED SURFACE MOUNTED 3-CIRCUIT CROSS RUNNERS LIGHT TRACT WITH BLACK FINISH, SEE ELECTRICAL SHEET. 'ORDINATE RDINATE WITH LIGHT >...........::.:........... • RER FOR INSTALLATION 0 SURFACE MOU i P'; ACCESS' � AND REQUIREMENTS, �► 3 �� +.,l tri'.':111' ., NOT USED _ 12 . TRACK LIGHT DETAIL USPENDED TILE CEILING SYSTEM _ FLUORESCENT FIXTURE ACT _ 4IMPri\'‘Tiv ,�ATH C c-1 NOTE: FLUSH ACCESS NOTES: PANEL, SEE CEIUNG PLAN 1. AREA OF CEILING BRACED NOT TO EXCEED 144 S.F. • CA ` FOR SIZE AND LOCATION. 2. MAXIMUM BRACE SPACING NOT TO EXCEED 12'-0" IN EACH 'I DIRECTION. 11 *cbc,CP 3. FIRST BRACING POINT WITHIN 6'-0" OF EACH WALL %. O 4. BRACE POINT ON MAIN RUNNER NOT TO EXCEED 2" DISTANCE MTL 'L' ANGLE FASTEN PRIMARY 12 GA. HANGER WIRE 0 FROM CROSS RUNNER. ATTACHMENT HARDWARE PER CARRY CHANNEL TO CROSS CARRY 4'-0" O.C. EACH WAY 5. COMPLY WITH UBC STD. 25-2. MANUFACTURER'S SPECS CHANNEL, CONE AROUND OPENING. FASTEN WITH SHEET MTL. SCREWS EXPOSED MAIN GRID FRT 2X4 BLOCKING ON 4'-0"MAX 8'-O"MAX MEMBER 0 4'-0" 0.C. :>�.:� 2 X 6 FRT BLOCKING Rik ®RATED CLG FIXED SIDES _ / — ( —/4 1 _ ,‘ i ... :::i ::: : :: O � " N\ GRID M0 1___./.1 z . 1 1311rAke O.C. ' di SEE RCP ISIMIlrial .' 2470 Mariner Square loop B.O. CEILIN 1 �!1bi_a / (4) 10 GA. GALVANIZED Alameda,a m e d a, C A I , SEE RCP 1®ft�!R__J _� ..i I! . .. „ , " 94501 I ..e. LING o STEEL WIRES CEILING BRACKET BY HAT CHANNELS 3 �, p SEISIuIIC COMPRESSION < COMPRESSION STRUCT 0 OWNER'S VENDOR � � ----1111--1111 FRT PLYWOOD STRUT 0 12" O.C. EACH 12'-0" O.C. ATTACHED TO BLOCKING WAY. SEE ri*"' l MAIN RUNNERS \ AfiLpl Qrawiags and written o:ft erial or herein caastitute arigiaal FREESTANDING FIXTURE ACCESS PANEL FRAME oar rnpuhlisher cork the Architect and nay oat he duplicated, DROP-IN ACCESS PANEL, 1111111111111111111P11111111111111111 used or disclosed without irittea consent of the Architect ®DH INTER FORMS, INC. DH ARCHITECTS- 2010 I I A SELF-TAPPING SCREWS FREE SIDES PERIMETER ANGLE Q A Q C TAPE JOINT, TYP. ACOUSTICAL TILE CEILING AND M E T A L SUSPENSION GRID No . D a t e I s s u e 05/28/10 100% SET 05/28/10 VT PACKAGE 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET 3'a�'_°" 3■�j'�"' 'I/ '1�'�' '�'-a" 08/13/10 PERMIT/BID SET FREE STANDING FIXTURE CEILING DETA4 ii ACCESS PANEL DETAIL 8 SUSPENDED TILE CEILING SYSTEM _ 5 SEISMIC CEILING BRACING o ACT _ 2 A NOTES: NOTES: v. 1. MAINTAINS CLEAR FROM SPLAY ONES TO MECHANICAL DUCTWORK. 1. MAINTAINS CLEAR FROM SPLAY UNES TO MECHANICAL DUCTWORK. 2. STRUT DESIGN IS BASED ON UNISTRUT GENERAL ENGINEERING 2. STRUT DESIGN IS BASED ON UNISTRUT GENERAL ENGINEERING LIGHT SEE lab' 1/2" EMT - RUN TIGHT TO STRUCTURE ABOVE CATALOG No. 14 CATALOG No. 14 le-7 jr (4`-0" MAX. FOR 1/2" 0) SECURE SUPPORT 3. STRUTS SHALL BE BY UNISTRUT OR APPROVED EQUAL. 3. STRUTS SHALL BE BY UNISTRUT OR APPROVED EQUAL. DETAIL 4/A6.1 a, SIM HANGER WIRE WIRES TO EXISTING STRUCTURE OR STUD INFIL L 6' TOP CUP /4./ SPRING CUP • 8 GA. VERTICAL HANGER WIRE 0 48" O.C. / ``: ' ' ALONG FRAMING (E) STRUCTURE / DECK /` / ATTACHMENT r 1 O'-2" A.F.F. ' HOLES • 3/4" EMT - BUTT TIGHT TO 1 5/8" METAL 1/2" EMT - RUN TIGHT TO MIL STUD i B.O. GYP. BD. CEILING COMPRESSION PO , JOIST FRAMING FRAMING ABOVE (4-0 MAX. FOR 1/2" 0) MECHANICALLY FASTENED • i r « c DRILL 5/32' HOLE FOR 1/8" BOLT AND SECURE SUPPORT WIRES TO STUD INFILL PER MFR RECOMMENDATION :1.1•.a. .__111-. lit Z LOCKNUT AFTER CEIUNG SYSTEM IS LEVELED ANGLE BRACKET Z NOTE: STRUT & BRACING WIRE NO < VERTICAL - 12 GA. HANGER WIRE 0 8 GA HANGER WIRE 0 48" OC & MORE THAN 2 FROM CROSS TEE 4'-0" O.C. WITHIN 6" OF END OF CARRYING O. INTERSECTION. 12 GA. HANGER WIRE 3/4" EMT - NOTCH OVER MAIN RUNNER CHANNEL 1 1/2" - < PAINTED DRYWALL i NOT REQ'D INSIDE STRUT ,I -/ SEE FINISH PLAN 45 MAX DRILL 5/32" HOLE FOR 1/8" BOLT AND SUSPENDED T-BAR GRID PER '�/� ICBO #224 _z T LEVELED �� �� (MECHANICALLY NOT TO EXCEED 4-0 Project N o. 44122 1 NOTE " .�� I: FASTENED) STRUT STRUT & BRACING WIRE NO MORE THAN < 1/4 FLAT HEAD 45 MAX. '�+" 2 FROM CROSS TEE INTERSECTION. r► " F A S T E N E R S ■ 4 5 (, BULB CUP 4 5. _ S c a l e AS NOTED--4 1 �` 12 CTC �. (MECHANICALLY SPLAY BRACE WIRE SLNT AND BACKER ROD. .,/ -' 7....i. .— � FASTENED) TYP. �, < +N STAINLESS STEEL TRIM 1 5/8 x 16 GA. MTL /'J !IMPENDED CElla DrawnBy: DM/AN cv JOIST FRAMING A 48 O.C. �� 401 o IAA -E " \ CENTER OF 3/4"0 �"' 45 ``� " co ►Mil ao 4 -12 GA. SPLAY - (3) TURNS MIN. IN 1 1/2 (TYPICAL) ti) HOLE O LA WIRES SPLAYED 90' FROM EACH OTHER ,, �- G�PB1IN AND 45 (MAX.) FROM CEILING PLANE 12-0 O.C. EA. WAY & �s 45' MAX. SEE RCP /- „ WITHIN 4—O OF EA. WALL r -�- R:\HM\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220..A61 b.d 1/2 THK. TEMPERED ^ B.O. GYP. BD. CEILING L CLEAR GLASS. POUSH 7/8" X 20 GA. MIN. CHANNEL FURRING 0 16" O.C. SECURE TO 1 • ALL EXPOSED EDGES 5/8" METAL JOIST FRAMING WITH MINIMUM 8 G A. WIRE A MAIN RUNNER D r a w i n g N o. ° DRAFT STOP SMOKE BAFFLE WITH CLAD. SUSPENDED ACOUSTICAL CEILING SEE MANUFACTURER SHOP DRAWINGS FOR 8'-8" A.F.F. CROSS TEE (4)-12 GA. SPLAY WIRES SPLAYED 90' ASSEMBLY. TO BE INSTALLED SURROUNDING NOTE: L/R = RATIO NOT TO EXCEED 200 FROM EACH OTHER & 45 FROM CEIUNG TILE PER FINISH SCHEDULE CEILING DETAILS B.O. DRAFT CURTAIN PLANE 1 2" 0.C. EACH WAY & WITHIN GYP. BD. WALL G.C. TO THE UNENCLOSED OPENING OF STAIR. 4'-0" OF EACH WALL PAINT PER FINISH SCHEDULE > = REFER TO RCP FOR LOCATION s'=�-o� �M=�-ar s•=�-o� 31=�r-o" 1 DRAFT CURTAIN DETAIL _ 10 TYP. GYP. BD. SUSPENSION DETAIL _ 7 TYP. SEISMIC CEILING BRACING 0 ACT _ 4 TYP. ACT DETAIL AT END _ A6 .1b OF DOOR & THRESHOLD NOTE: , REVIEW SPECIFICATIONS DMSION IX "FINISHES" ADA COMPLIANT ALUMINUM FOR FLOOR FINISH INSTALLATION. r TRANSITION. SEAL, CAULK & HOLLOW METAL DOOR — INSTALL PER MANUFACTURERS SEE DOOR SCHEDULE > INSTRUCTIONS BM i / Bo;:, ill$114 I VCT-1 N SHEET FLOORING OVER < EXIT OR SERVICE DOOR, WHERE �' CONCRETE LEVELING COMPOUND OCCURS — REFER TO DOOR ...,. SCHEDULE. PROVIDE WEATHER STOP/ R SWEEP (EXTERIOR DOOR NOTE. LOCATIONS) REVIEW SPECIFICATIONS DMSION IX 'FINISHES" US220 FOR FLOOR FINISH INSTALLATION. SALES AREA LL EXIT COMDOR FULL WASHINGTON SQUARE NOTE: G.C. TO PROVIDE A.DA WALL AS SCHEDULED > ALUMINUM THRESHOLD _ 3B 2" / APPROVED EXTERIOR ALUMINUM S.W. WASHINGTON SQUARE /1 THRESHOLD (PEMKO #252A OR SUITE H08 CST-1 EQUAL) AT EXTERIOR DOOR - — PORTLAND OR 97223 , LOCATIONS. SEAL, CAULK, FLASH VINYL BASE DOOR FRAME -7% a ND �' SERVICE 00 DULE SEE AND INSTALL PER HALLWAY 80H CLASS: RED •• MANUFACTURERS INSTRUCTIONS. —1 r =-TOR 1_ N ADA APPROVED EXIT ALUMINU WEATHERSTRIPPING VCT-1 THRESHOLD. SEAL, CAULK, FLASH EXTERIOR DOOR & INSTALL PER MANUFACTURERS EXISTING CONCRETE INSTRUCTIONS L.L. EXIT SLAB 0'—O" A.F.F. v i� CORRIDOR/EXTERIOR FINISH FLOOR CST-1 VCT-1 .. EXISTING CONCRETE (E) CONCRETE SLAB 1 WHERE OCCURS. TAT . SLAB SEE FINISH PLAN NO 10 X 1-1/2" FHWS, g : PHILLIPS (FACTORY PROVIDED) NOTE: REVIEW SPECIFICATION ; SION IX "FINISHES" FOR FLOOR FINI - 'STALLATION. ` ! .' , FULL 8"=1-01" FULL \t' i1 NOT USED _ 12 TILE TO MALL FLOOR 9 VINYL BASE 6 - ERIOR THRESHOLD 0\1 -I - - . .�� , .. . ATF! •HOLLOW MT . DOOR — SEE p I' en AUGN TOP OF BOTH FLOORING A 4 DOOR SCHEDULE " ELEVATOR DOOR PANEL, 4'—on A.F.F. ALAMEDA, CA MATERIALS W/ TOP OF ZINC SILL AND ANGLE SILL BY — TOILET ROOD DMDER STRIP 1 2" SEALANT T.O. WAINSCOT BOH `" ' WITH BACKER ROD VENDOR, REFER TO SHOP _ .4 ': ALIGN TOP OF BOTH ADA COMPLIANT MARBLE ' C§S LC-1 - i_{. , J MOLD FLOORING MATERIALS WITH THRESHOLD. SEAL, CAULK, FLASH I AND JOINT FILLER— TOP OF ZINC DMDER STRIP WAINSCOT OVER 5/8" GYP. BD. & INSTALL PER MANUFACTURER OVER MIL. STUD FRAMING > 2 2 INSTRUCTION A ° %/ WP-1 — If. 4 1:/.....AX MAXI 1 1 A �. D .. , g II N V I le WATERPROOF MEMBRANE. • le EXTEND 8' UP WALL 3� O'-6" A.F.F. NOTE: IV T.O. BASE WALL AS SCHEDULED. > NOTE REVIEW SPECIFICATIONS DIVISION IX "FINISHES" REFER TO FINISH PLANS REVIEW SPECIFICATIONS DMSION IX 'FINISHES' FOR FLOOR FINISH INSTALLATION. FOR FLOOR FINISH INSTALLATION. FULL BASE FULL Dennis Heath, Architect ELEVATOR FLOOR TRANSITION DETAIL _ 11B : r , _1 MARBLE THRESHOLD _ 2B 24/0 Mariner Square Loop JANITOR CLOSET = Alameda, CA 94501 THIN SET COVE TILE BASE � � co � . RUBBER REDUCER STRIP — ALIGN TOP OF BOTH FLOORING OVER WATER PROOF MEMBRANE > 1 TO MATCH CARPET MATERIALS W/ TOP OF ZINC TILE SALES AREA DIVIDER STRIP ESCALATOR FLOOR CLOSURE CT-1 CST-1 �, GLUE DOWN CARPET OVER w ' IC —1 1/2" SEALANT ANGLE AND PLATE BY ESCALATOR TILE (USE MINIMAL G " Billings gad written material appearing herein constitute original WITH BACKER ROD VENDOR, REFER TO SHOP N C and uapuHished cork of the Architect and may not be duplicated, AN) JOINT FI_a' DRAWIN GROUT JOINT -: I CP— OR CP-2 used or disclosed without written consent of the Architect . "1". 0'-0" A.F.F. cODH ARCHITECTS- 2010 1 FINISH FLOOR �►- ,,�_..._., �,- ..•-•-�► •.,-. o ��1t�1e��_'1: !terns itstt�stl�it/1.ttelN�:�alt�ttraliel Allilll . . - 0-0 A.F.F. . . _ _ . . . . � b QAQC f FINISH FLOOR . . . . . . . .� ��I .®. 1' ; Issue 05/28/10 100% SET 05/28/10 VT PACKAGE NOTE: NOTE E ',CRETE SLAB REVIEW SPECIFICATIONS DMSION IX "FINISHES" REVIEW SPECIFICATION - ■SION IX FINISHES" ( ) 07/02/10 100% COMPLETE SET FOR FLOOR FINISH INSTALLATION. FOR FLOOR FlNI ALLAlION. 07/28/10 LANDLORD SET FULL 6'= —O' �"�T—(�' � � FULL -.Ng PERMIT/BID SET _ JANITOR'S _T _ _ 'lle ESCALATOR FLOOR TRANSITION DETAIL 11A WAINSCOT DETAIL o 8 WOOD BASE 5 - PET TO TILE ii.L., 0 4'-0" A.F. _ ALIGN TOP OF BOTH FLOORING T.O. WAINSCF.OT MATERIALS W/ TOP OF ZINC DMDER STRIP G.C. TO USE 2" BULLNOSE BOH GROUT JOINT SALES AREA TOP PIECE AT ALL EXPOSED . lt. EDGES VCT-1 i ( _1 5/8 GYP. BD. OVER 3/4" PLY. WD. OVER - \� MIL. STUD FRAMING > dbi THIN SET CERAMIC TILE IV 4'—O" A.F.F. OVER CEMENT BOARD .� T.O. WAINSCOT PANEL CT-1 i ;I r I\ • J—MOLD FEATHER FILLER TO EXISTING 1 II oj 0'-6" AF.F. — n i FLOOR SLAB — SLOPE TO BE `4' T.O. BASE NOTE 1/4. IN 1'-0" MAX. HALLWAY 1 REVIEW SPECIFICATIONS DMSION IX "FINISHES' / WAINSCOT OVER 5/8" GYP. BD. I FOR FLOOR FINISH INSTALLATION. ÷ .. ® OVER 3/4" PLY. WD. OVER MIL. -/ I FULL STUD FRAMING, SEE > . WATERPROOF MEMBRANE. TILE TO VCT _ lB EXTEND 8 UP WALL WP-1 Project No 44122 THIN SET COVE TILE BASE -- I 00 PROOF VINYL BASE OVER WATER S c a l e AS NOTED MEMBRANE MATERIAL TO MAINTAIN A OFLUSH VB-1 ;, CT-1 I GROUT JOINT TITTION x i DrownBy: DM/AN I VCT-1 GROUT JOINT I I CST-1 I MALL FLARING I I FRP WAINSCOT OVER 5/8" GYP. 0'-0" A.F.F. v ,i CT-1 I _ V v V V A BD. OVER 3/4" PLY. WD. OVER "V FINISH FLOOR 0'-0" A.F.F. R:\HM\Projects\2010_Projects\44122 Washington Sq\Drowings\CA\US220_462.d MTL STUD FRAMING, SEE � .....:: FINISH FLOOR Q WP-1 r-- -... :... .-- _ ....'„, — - —�. Drawing No. 0 FLOOR & BASE DETAILS N 3 X 3 X 26 GA. AT 48" Ni HIGH S.S. CORNER GUARD .: NOTE. (E) CONCRETE SLAB REVIEW SPECIFICATIONS DMSION IX 'FINISHES" FOR FLOOR FINISH INSTALLATION. L 6114-0" Ir=1-0" 6'=f-0" FULL _. CORNER GUARD AT BOH 10 WAINSCOT DETAIL o BOH 7 TILE AT TOILET ROOMS _ 4 TILE TO MALL FLOORING _ 1A A6. 2 ..,.. _ (-1,7 iii 3%' 1/4" THICK SIGNAGE NOTES: EQUILATERAL 1. PR► 4 DE DRINKING FOUNTAIN ONLY IF. REQUIRED, BY CODE IF THE DRINKING FOUNTAIN IS LOCATED IN THE PATH OF VEL, ' TRIANGLE ETAL STUDS AS OCCURS A TUTU', • AREA 1'-0" AROUND THE FOUNTAIN, CLEARLY IDENTIFIABLE BY THE BUND IS REQUIRED, BUBBLER IS • BE 1. WHEN SIGNS IDENTIFY A PERMANENT ROOM OR SPACE OF A BUILDING OR SITE, OR WHEN SIGNS DIRECT OR GIVE INFORMATION ABOUT A ACTIVATED ' A HANDICAP PUSH BAR ON THE FRONT FACE OF UNIT. PERMANENT ROOM OR SPACE OF A BUILDING OR SITE, CORRESPONDING TACTILE SIGNAGE SHALL BE INSTALLED. . \ SEE PLAN 2. WHEN SIGNS IDENTIFY, OR GIVE MORE INFORMATION ABOUT ACCESSIBLE ELEMENTS AND FEATURE OF A BUILDING OR SITE, THEY SHALL INCLUDE 2. ONLY PROVID '' LING IF DRINKING FOUNTAIN IS IN THE PATH OF TRAVEL. THE APPROPRIATE SYMBOL OF ACCESSIBILITY OR PICTOGRAM WITH THE EQUIVALENT VISUAL AND TACTILE DESCRIPTION PLACED DIRECTLY BELOW — cv c4 3. THE BUBBLER CAN ' ACTIVATED BY THE HAND OPERATED LEVER LOCATED WITHIN 6 INCHES OF ' FRONT OF THE ildi THE PICTOGRAM. THE OUTSIDE BORDER OF THE PICTOGRAM SHALL BE MINIMUM fi" IN HEIGHT. .- IllreNi -- -: FOUNTAIN OR BY A PUS :� ' ALONG THE FRONT OF THE FOUNTAIN. VISUAL CHARACTERS SHALL BE UPPERCASE, STANDARD SANS SERIF FONT. THE HEIGHT OF VISUAL CHARACTERS SHALL BE A MINIMUM 5/8" PLUS E MEN WOMEN 3. � :. 1/8" PER FOOT OF VIEWING DISTANCE OVER SIX FEET. CATER WIDTH SHALL BE 55% MINIMUM AND 110% MAXIMUM OF THE HEIGHT OF THE \.. 4. A SECOND DRINKING FOU SHALL BE PROVIDED WITH A BUBBLER HEIGHT OF ±46' F0► 'EOPLE WHO HAVE DIFFICULTY CHARACTER. CHARACTER STROKE WIDTH OF VISUAL ONLY CHARACTERS SHALL BE A MINIMUM OF 10% OF THE CHARACTER HEIGHT, AND A ..- BENDING OR STOOPING. MAXIMUM OF 30% TACTILE SIGNAGE DUPLICATING THE INFORMATION SHALL BE PROVIDED, EITHER AS PART OF THE VISUAL SIGN OR A SEPARATE 1/4" THICK CIRCLE NOTCH STUDS AS REQUIRED TACTILE SIGN PROVIDED. 5, THE BUBBLER SHALL PROVIDE A FLT OF WATER AT LEAST 4 INCHES HIGH, ON A 'e UNTAIN WITH A ROUND OR OVAL BOWL 4. TACTILE CHARACTERS SHALL BE UPPERCASE, STANDARD SANS SERIF FONT, RAISED 1/32" OFF THE BACKGROUND. THE HEIGHT OF TACTILE THE SPOUT MUST BE POSITIONED SO TH OW OF WATER IS WITHIN 3 INCHES OF E FRONT EDGE OF THE FOUNTAIN. CHARACTERS SHALL BE BETWEEN 5/8" AND 2" CHARACTER WIDTH SHALL BE 55% MINIMUM AND 110% MAXIMUM OF THE HEIGHT OF THE DOOR MOUNTED SIGNAGE \ .z MANUFACTURER'S STANDARD FLANGE, SURFACE CHARACTER. CHARACTER STROKE WIDTH SHALL BE A MINIMUM OF 10% OF THE CHARACTER HEIGHT, AND A MAXIMUM OF 15% CHARACTERS N.T.S. �� MOUNTED. WITH SET-SCREWS, OVER STANDARD SHALL BE ACCOMPANIED BY GRADE 2 BRAILLE. CONCEALED MOUNTING PLATE US220 5. GRADE 2 BRAILLE SHALL HAVE A DOMED OR ROUNDED DOTS RAISED 1/40" OFF THE BACKGROUND, WITH DOTS SPACED 1/10" WITHIN CELLS, - =�' CAULK AROUND AND 1/4" BETWEEN CELLS (OR SPACED PER ANSI TABLE 703.5). CENTERLINE OF _ `, _ SEE ENLARGED ELEVATION ALL (3) SIDES - ' 1 a. WASHINGTON SQUARE « " SYMBOL {TYP.) :=J FOR MOUNTING HEIGHT � TO MATCH WALL 6. TACTILE SIGNS SHOULD BE MOUNTED 48 MINIMUM TO THE BOTTOM OF THE SIGN, AND 60 MAXIMUM ABOVE THE FLOOR TO THE CENTERLINE FINISH. 4 95 5 S.W. WASHINGTON SQUARE OF THE SIGN. AN 18 X 18 CLEAR SPACE IS REQUIRED IN FRONT OF THE TACTILE SIGN, BEYOND THE ARC OF ANY DOOR SWING. WHERE DOOR & SYMBOL 1-1/2" O.D. GRAB BAR �ti SUITE H08 SIGNS ARE MOUNTED AT DOORS, THE SIGN SHALL BE ON THE LATCH SIDE OF THE DOOR. WHERE SIGNS ARE MOUNTED AT DOUBLE DOORS, OR ADD F.R.P. & �:1 PORTLAND, OR 97223 WHERE THERE IS NO WALL SPACE, THE SIGN SHALL BE MOUNTED ON THE NEAREST ADJACENT WALL, PREFERABLY THE RIGHT SIDE, " _ , ;M�� , ./ / 1 1 2 CLEAR J MOLD ON (3) `� 6, CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND. CHARACTERS, SYMBOLS AND BACKGROUNDS SHALL HAVE A NON-GLARE 6 - ►7` / / �i • [ � /1 �><y� SIDES FROM N.,„ CLASS. RED FINISH, �,.;�:, o o FINISHED FLOOR TO ~ / CEREMIC TILE OVER GYP. BOARD, SEE ELEVATION 48" A.F.F. 4 ri6.1C:k. i 6%' 11.1 & & 30" x 48" MINIMUM � � � 6"W X 16 GA. BACKING PLATE TACK L `�' � CLEAR FLOOR SPACE WELD TO METAL STUDS, MIN. OF 3-STUD CENTERED UNDER LOW SPACES OR LENGTH AS REQUIRED � DRINKING FOUNTAIN UNIT UNISEX MEN WOMEN RESTROOMS V‘71------- !l�L�EX MEIN WOMEN TACK EACH STUD FLANGE EACH EDGE TYP. ; - i'.'ti 0 WALL SIGNAGE TOILET ROOM DOOR SYMBOLS N.T.S. N.T.S. EMIL .i M,l�.i ..„lit N.T.S. 3” =J.°. �ACCESSIBLE TACTILE SIGNAGE 3 GRAB BAR MOUNTING DETAIL 6 I-.LO DRINKING FOUNTAIN .i , i, 1 B.O.H. ACCESSORY SCHEDULE tin * PROVIDE 1-1/2" CLEAR ABOVE TANK NO. DESCRIPTION QTY MANUFACTURER MODEL] ALAMEDA• CA RAISE BAR TO 36" MAX., IF TANK OBSTRUCTS 1 PLATE GLASS MIRROR 1 BOBRICK TILT MIRROR W/ S.S. FRAME 24" X 36" ',,,s1) B-293 SERIES 2436 '" P OF Ok(% q.31-4" A-18 GRAB BARS 1 BOBRICK 1 1/2" DIAMETER S.S. GRAB BAR CONCEALED MOUNTING / / © L B-36"L GRAB BARS 1 W/SNAP FLANGE B-6806 • PAINTED GYP. C-421 GRAB BARS 1 BD. • U PAPER TOWEL DISPENSER 1 SAN JAMAR 11 1/2"W X 11 1/4"D X 13 1/2"1-1, SURFACE MOUNTED. .. DASHED UNE PT-1 INTEGRA LEVEL ROLL TOWEL DISPENSER. MODEL T850TBK INDICATES TOP INSTALL BACKER 24" DASHED UNE OF WALL ROD AND CAULK / INDICATES TOP TOILET PAPER DISPENSER 1 SAN 12"H X 19"W X 5 1/4"D SURFACE MOUNTED. TWIN JUMBO 18" GRAB BAR CERAMIC TILE. TYP. (3) SIDES. OF WALL U ROLL BATH TISSUE DISPENSER. MODEL ER409OTBK Cl CT-1 (TOP, LEFT & \ CERAMIC TILE. 42" GRAB BAR RIGHT) > CT-1 r-7 5 TOILET SEAT COVER 1 JANIMART 1 6"W X 3 1/4"D X 11 1/2"H, SURFACE MID. WHITE PLASTIC. I DISPENSER G.C. TO ALIGN USE OF BULLNOSE / 1.-0" / OUTLET WITH PIECE AT ALL SOAP DISPENSER 1 SAN JAMAR 6"W X 3"0 X 9 1/8"11, SURFACE MID. MODEL BOB40 DR* 36" GRAB BAR 3 TOP OF BASE ;a EXPOSED EDGES, r U DISPENSER. (1) PER RESTROOM, MOUNT AT 40" A.F.F. MAX, C 1-1— F21< U AND TILE TYP. SEE 4/A6.2 < Dennis Heath, Architect , AIR FRESHENER 1 CLAIRE CLAIRE METERED AIR FRESHERNER �, (� \ � � V � \ 2410 Mariner Square loop ITI (1) PER RAM, COORDINATE LOCATION WITH PM ON SITE <> I I tom► COAT HOOKS 1 BOBRICK HEAVY DUTY SURFACE MOUNTED COAT HOOKS ON DOOR. Alameda, CA 94501 I m , 1r r..... V )\ ° V 1 al 8 B-2116. (1) PER RESTROOM, MOUNT AT 54" A.F.F.C s 1 �.t' UU 0 f ,e. €� i t I 9 WATER CLOSET 1 - REFER TO PLUMBING DRAWINGS r " / 10 LAVATORY 1 - REFER TO PLUMBING DRAWINGS Drariaga and arittea material appearing herein constitute originol M �i' \ `� " « \ - and unpublished rork of the Architect and eat not be duplicated, • / in 7 -9 M used or disclosed without arittea consent of the Architect z FLUSH HANDLE MUST c D H ARCHITECTS- 2010 QAQC BE ON "OPEN" SIDE I Ty7 0 OF WATER CLOSET 7 COVE TILE AT BASE. ("4-: l 10 ("4-'), ,NOTES: \ \ - \ \ G.C. T O ALIGN GROUT AA 6•2. ,• 6 A6.3 A�6•�iTYP, 5 4 1. PAPER TOWEL DISPENSER + TOILET P A P E R DISPENSER + S O A P DISPENSER + TOILET S E A T COVER DISPENSER + N o . D a t e I s s u e UNES FROM FLOOR AIR FRESHENER + TRASH CANS PROVIDED & INSTALLED BY G.C. 05/28/10 100% SET 0 ELEVATION TO WALL ELEVATION ELEVATION 2. VT PACKAGE 17"-19" TO TOP OF TOILET SEAT COVE TILE AT BASE : 2, URINALS: PROVIDE ALL WALL HUNG URINALS WITH ELONGATED RIM. FLUSH CONTROLS ARE TO BE HAND OPERATED AND ARE TO MEET THE SAME REQUIREMENTS AS THE FLUSH CONTROLS FOR THE WATER CLOSET AND ARE TO BE A 07/02/10 100% COMPLETE SET MAXIMUM OF 44 INCHES ABOVE THE FLOOR. RIM ELEVATION TO BE 17 INCHES A.F.F. 07/28/10 LANDLORD SET 3". = 114Y1 1/741/74-0° 3. PLUMBING FIXTURES FURNISHED AND INSTALLED BY G.C. AS SPECIFIED. 08/13/10 PERMIT/BID SET TOILET ROOM ENLARGED ELEVATION _ 11 RESTROOM ELEVATIONS 5 4. ALL OTHER ACCESSO R IES FURNISH ED AND INSTALLED BY G.C. ACCESSIBLE RESTROOM SIGN 0 GRAB BAR NOTES 60" A.F.F. ON LATCH SIDE tit__ — GRAB BARS SHALL NOT ROTATE AND THERE ARE TO BE NO SHARP, OR ABRASIVE ELEMENTS ON OR ADJACENT TO THEM. _ EDGES ARE TO HAVE A MINIMUM OF 1/8" RADIUS.MIRROR, SEE PLAN FOR TYPE / — — — _ - GRAB BAR BACKING AND ATTACHMENT SHALL BE CONSTRUCTED FOR A 250 POUND POINT LOAD.\ , N WALL HUNG LAVATORY, �ti SINK NOTES: SEE PLUMBING DRAWINGS �/ � / �''6 i�\1 </ F51 / / "JR SMITH X700 {M31)" / INSULATE HOT WATER AND DRAIN PIPES UNDER LAVATORIES TO CONFORM WITH ALL LOCAL STATE AND FEDERAL \ / MIN. FLOOR MOUNTED LAVATORY A6.3 I I 4 / 11 ACCESSIBILITY AND ENERGY CODE REQUIREMENTS. NO SHARP OR ABRASIVE SURFACES ALLOWED UNDER LAVATORIES. SUPPORTS WITH CONCEALED — — — — UU \ I- _ 1(� 30•x48 U r FAUCET CONTROLS AND OPERATING MECHANISMS MUST BE EASILY OPERATED BY ONE HAND AND MUST NOT REQUIRE ARMS - 1x3 STEEL UPRIGHT B i ! \ GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE NEEDED TO ACTIVATE CONTROLS SHALL NOT EXCEED 5 LBS. . \ ■& 4" SQ. STEEL BASE \ 60"x59' FOR LEVER OPERATED OR 15 LBS, FOR PUSH TYPE. / / 1.r..1 _A\ I \ F.: g / w t C \ = , < \ E , v, / s / I !---- ___,‘) ..t. n PROVIDE METAL STUDS AND ' _ / 10 3 > 1 1 " _ Project No. 44122 PROVIDE INSULATED WRAP 8 MIN' V INSULATION PER WALL TYPES. A / T ALL EXPOSED PIPING 1 CI• 1\ ir 9 C ' Scale AS NOTED � a o U = -' a" ? CONTINUE WALL FINISH L - - _e- — U `,J L — — _ ` . b m ca BELOW VAINITY « L = Lao\g i n z PROVIDE 4 LEAD EXPANSION ° ° ° , 1 U I ° ° ° D r a w n B DM AN 5 ANCHORS AT EACH BASE N PLATE PER MAUFACTURER'S N UNE OF MIN. / MAX. \ RECOMMENDATIONS ACCESSIBILITY CLEARANCES z • CONCRETE FLOOR R:\HM\Projects\2010_Projects\44122 Washington Sq\Drowings\CD\US220 .A63.d / 6 / FINISH FLOOR MAX, 18" 24" MIN. 18" / �- / /- 'T Lf1 �+ .� �/ Draping No. 0 FLOOR DRAIN - SEE EE PLA PLUMBING DRAWINGS RESTROOM DETAILS N N AND ACCESSIBILJTY FO WALL E COMPLIANCE a 0 r - �� ���—�� 4 ACCESSORY SCHEDULE N'T�' _. SECTION AT LAVATORY 10 TOILETROOM PLAN _ _ A 6 .3 ,. A.F.F. 4,11 h 4'-811 . NOS: CHROME BUGLE HEAD .0. WARDROBE REFER TO INTERIOR INSTRUCTIONS FOR CASH POINT SCREWS W/ WASHERS WARDROBE COMBINATIONS ICI TO SECURE PANEL, IYP. PAINTED COLUMN. \ I __ All- ALL (4) CORNERS /V._• REFER TO SHEET ,_ l l 15" X 18" X 5/8" A.02 FOR FINISHES > 2 3 1/2 EQ o< GARBAGE AND )), / �. ci MDF ACCESS PANEL— \ \— MIN. DISTANCE ON *7•4-I SHELFS s - �, PAINT ADJACENT MATCH FINISH < co EACH SIDE WHEN UNIT .,� o IS PLACED NEXT TO < AREA FOR T <> WALL FRAME OR HANGERS = - -- - a- °D WARDROBE. » ADJACENT PAINTED t° to 8 8" I / /MIN./ G o YP. BD. 0'-0" A.F.F. MIN' _ MIN. 0 0 ci FINISH FLOOR < w PROVIDE BLOCKING \ r- 5/8 GYP. BD. OVER 5/8 PLYWOOD = BEHIND BASE AS �- 11-3 1/4. R.O. BaCKWRAP FRONT ELEVATION OVER MTL STUD FRAMING / REQUIRED > 0 < FOFNEOTRr PLACE THE I ~ (: ` US220 EET -� 1r ,� � MIRROR ON THE 1 w X w w WARDROVES AT FINISHES 5 18 X 5/8 WASHINGTON SQUARE ELEVATION _ ECTI BACKWRAP BEYOND > 0, FIXED TO COLUMN A 1 2"=1'-0" MDF ACCESS PANEL— BACKWRAP ON 1 w=1�_Ow / PAINT TO MATCH 1-1/2"=1'-0" S.W. WASHINGTON SQUARE < WARDROVES AT a ADJACENT FINISH Aik 3'-2" A.F.F. I I BACKWRAP SUITE H08 COUNTERTOP PORTLAND, OR 97223 CASH DESK SHOULD CLASS: RED BE LEVELLED WITH 2X WOOD< \ MIN. DISTANCE ON ADJUSTABLE FEET BLOCKING EACH SIDE WHEN UNIT <> � , <> IS PLACED NEXT TO —RUBBER CARPET WALL FRAME OR PROVIDED BY TENANT ° I�J Immounall WARDROBE. 1 VENDOR A dk 0'-0" A.F.F. r v I FINISH FLOC l It L }{� '� �j'� LL ll l�,� ` 4'-1 " 1/8" 1'-3" PANEL 1/8. 1 / 12.-3" / 8 / / 2 0 / 3 8 / 2 5 / / / 1'-3 1/4- R.O. MIN. � / 0 MIN. TYP. FOR 3 CASH DESK COMBINATION MIN. HOLD FRONT ELEVATION 0 SIDE ELEVATION ADJACENT PAINTED CASHWRAP FRONT ELEVATION SIDE ELEVATION PLAN GYP. BD. 3"=1'-0" 1 I 1 , ; ti.,4 liI\Ili,i II I t A HWRAP AND B11 -0 =? 0' 1 1/2 � 0" �C S 9 MIRROR FOR WALLBREAK ACCESS 3 fi PANEL DETAIL _ Cul REFER TO PLANS FOR WHITE OR BLACK METAL FINISH • ALAMEDA, CA ---\/‘I-- — MTL STUDS FRAMING Q' •- 5/8" PAINTED TYPE 'X' GYP. BD. 0/ '4' C 5 8" F.R.T. PLYWOOD FROM TOP OF Of' C) — PAINTED COLUMN. SLAB TO 6" ABOVE STORE CLG, OR TIGHT TO MALL DECK ABOVE AS REFER TO SHEET REQUIRED PER LOCAL BUILDING _ — — — — 1 A.02 FOR FINISHES > AUTHORITIES /EQ./ 2'-3 1/2. /EQ./ SEE DIMENSION PLAN 0 \ WAIL o �� ' 1116011P 1 O'-2" A.F.F. .. s B.O. CEILING cl ..............„.............,,„.„..... : I ( \ 5/8 . EILING. G.C. TO GYP PAINT BD.PER I II I PLACE THE o I MIRROR ON THE Z Dennis Heath, Architect :: FINISH SCHEDULE ' \ _- - \ (I / \ Lapp 1; ; GYP, BD. OVER MTL. (� I » TO COL MN > FIXED TO COLUMN g FRAMING 2 X 2 STEEL • TUBE COLUMN, TYP. �, o A I a m e p, C A 9 4 5 01 ,,::: . „. 5/8 GYP. BD. OVER > ^a Pn : r MTL STUD FRAMING I o ,i RUBLE ACCESS DOOR N li w < BOXWALL BACK OF BOXWALL SHOWN DASHED Ororinga and Britten material appearing herein constitute original loo I _ ,n and unpublished cork of the Architect and iwer not be duplicated, " —�' written of the Architect =. or disclosed without rri en consent o e �rchi ec —0 A.F.F. used o ue J1 WALL BASE > (DOH ARCHITECTS- 2010 V H , 1, I —EXISTING COLUMN T O REMAIN. MAINTAIN EXISTING Q A Q C I FIREPROOFING AS APPLICABLE / 18'-0" / 3'-31/4" No . Date Issue MIRROR INSTALLED ON COLUMNS WHERE < UNE OF WALL BEYOND, MIN. 05/28/10 100% SET SHOWN DASHED FRONT ELEVATION al SIDE ELEVATION APPLICABLE. SEE DETAILS 4/A6.5 05/28/10 VT PACKAGE < 2" X 2" STEEL TUBE, SEE 07/02/10 100% COMPLETE SET STRUCTURAL DRAWINGS 07/28/10 LANDLORD SET BOXWALL BACK ELEVATION u.v=ir-tr 8 MIRROR FOR PORTAL 1/2"0-0" COLUMN DETAIL Furro-o. 08/13/10 PERMIT/BID SET a Ui a NOTES•> ` ' REFER TO PLANS FOR WHITE OR BLACK METAL FINISH / /2 / N ENTIRE ASSEMBLY IS CONSTRUCTED BY GENERAL CONTRACTOR. UPON COMPLETION OF PROJECT, GENERAL CONTRACTOR MUST RUN A NEW SET OF BLUEPRINTS OF THE COMPLETED STORE DRAWINGS (ARCHITECTURAL MECHANICAL, ELECTRICAL, / 1'-8" / ,t„ - - STRUCTURAL) AND PLACE INTO PLAN TUBE HOLDER CONSTRUCTED BY THE GENERAL CONTRACTOR. • In PAINTED COLUMN. FIX BARSWITH REFER TO SHEET SCREWS TYP. A.02 FOR FINISHES > _ „____ BOX 7.A, A, BOX 4 BOX 14 BOX 10" ,BOX 6/ BOX 2 BOX 4 ir < — ——EQ. EQ. r I LOOSE PVC 1/4 w DIAMETER THRU BOLT (E) BEAM / / / T CAP F , BOX 9 w 'TOGGLE o 2 T , Box 9 \ 48" A.F.F.• PAN HEAD SCREWS GYP. BD.— TO SECURE STRAP ■ BOX 4% BOX 4 NI BOX 4 Box 2 3/4X 2" POPLAR BOX 9 r?; " 1-----Nr------ ' i '( pii",17 , j sox 4 aax 1F ox4i PLACE THE MIRROR AL STRP/ /VBOX 9 BO .. �I T (TYOF r r — T T O COLUMN > \ ARE FIXED T O P r o j e c t No. 44122 BOX 4 BOX 7 ,... c, COLUMN I _s. r G.C. MUST PROVIDE :sox 6/ i /� _ 2 x 4 : Box 4 X BOX 4 _ = (WITH CLEAR TAPE) S c a l e AS NOTED I- — // o , • BOX 9 I > STATING: = « BOX frjYN 2 X 2 STEEL TUBE SEE � 8" DIAMETER D r a w n B y: DM/AN ' WOOD HOLDER THIS TUBE CONTAINS PVC TUBE STRUCTURAL DRAWINGS - STORE DRAWINGS AND IS E NOT TO BE REMOVED ° 0 ■ _ PVC BOTTOM CAP WITHOUT THE CONSENT OF _ THE STORE MANAGER. ° WALL BASE �+- �: 'tr, GLUED IN PLACE -° THANK YOU. R:\HM\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220_165.d �� 1 18'_0» > L---J / / � . 1 1 Drawing No. O 0 : .5/8" GYP. BD. CEILING. MIN, ELEVATION PLAN MISCELLANEOUS G.C. TO PAINT PER �- FRONT ELEVATION SIDE ELEVATION DETAILS FINISH SCHEDULE \� 5/8" GYP. BD. OVER MIL. ,, STUD FRAMING o A6.5 ... BOXWALL SECTION 1 1/214-0" ia BOXWALL FRONT ELEVATION V4 =r-O 7 MIRROR AT COLUMN 1/70-0" 4 TUBE H LDER -11 =t-O• i O - og_ +TE. • NOTE: 1. 'EFER TO A0.2 FOR FINISHES AND RESPONSIBULITY SCHEDULE Ala 1. REFER TO A0.2 FOR FINISHES AND RESPONSIBULITY SCHEDULE 2. W., FRAME FIXTURE DELIVERED AT 11'-7 3/4". G.C. TO CUT _ A6,1 2. WARDROBE FIXTURE DELIVERED AT 9'-3 1/2". G.C. TO CUT ON SITE ON SIT 0 ADJUST FOR LOWER CEILING HEIGHT, IF NEEDED r -1-17-0.1r- 6,1a TO ADJUST FOR LOWER CEIUNG HEIGHT, IF NEEDED 3. REFER 4 INTERIOR INSTRUCTIONS FOR MORE INFORMATION I HOLD 3. REFER TO INTERIOR INSTRUCTIONS FOR MORE INFORMATION l r L _ - _ IL , .. - SEE RCP :.f ...`` SEE RCP SEE RCP li,_ I\ c� I B.O. CEIUNG. B.O. CEILING. B.O. CEILING. G.C. TO INSTALL 1 4 V = I « « FRY REGLET REVEAL 772:::. «i Z 4 , 5/8 GYP. BD. OVER 5/8 1 ; PLYWOOD OVER MTL STUD MOLDING AROUND I I " , FRAME TO BE = cx z / 2�-0'� FIXTURE 9I-3 1 2 A.F.F. A liaM STENED INTO FLOOR & N gg MIN. FRAMING T.O. SOFFIT CEILING, TYP. REINFORCE J c.3 4.1! FLUORESCENT LIGHTS WITHIN ---- 1 _ - -, imilmommommammommmilmmimaymm CEILING TO ACCOMMODATE / FOR ATTACHMENT. SEE �� FIXTURE. GC. TO INSTAL AMC • I ,' PAINTED GYP. BD. METAL BACKING I LIGHT NEXT TO THE OTHER WALL BEYOND PLATE BEHIND RCP FOR LOCATION l ; `" FOR AN EVEN FLOW OF UGHT. I 1'-7" / GYP. BD. ALL THE WAY BEHIND PANELS. FRY REGLET REVEAL TYP. UNE OF PAINTED WALL MOUNTING BRACKET REFER TO RCP & MEP MOLDING AROUND :Ile BEYOND, SHOWN DASHED DRAWINGS /T/ U S 220 -I i� �i//�,/, FIXTURE. TO BE 1��L %//�����/i�ii���_ i��������������._�i����� / METAL BACKING PLATE OVER • PAINED GYP. 8D. WAIL PURCHASED BY G.C. WASHINGTON SQUARE � PURCHASED BY G.C. SEE PAINTED MDF END CAP. Now111141E1 ("-i 9585 S.W. WASHINGTON SQUARE e � 10/A6.0 lr c,s FURNISH AND INSTALLED BY/l co z G.C. FINISH TO MATCH 6" STRIP OF 5/8" ,-'' SUITE H08 ' ;�, ADJACENT WALL COLOR PLYWOOD OVER MIL. CO PORTLAND OR 97223 ai0© STUD FRAMING. TYP. 4 i ( AT (2) LOCATIONS. CLASS: RED WALL FRAME FIXTURE TYP. -r- WARDROBE FIXTURE, TYP. cv ......-*/ TO BE INSTALLED TO 1" WARDROBE MOUNTING ANGLES. TO BE • PAINTED GYP. BD. WALL WALL BASE FlXTUR TYP. PURCHASED BY G.C. BEYOND E, FOOT PLATE. GC TO USE fi STRIP OF 5/8 ALL BASE BEHIND WALL U-PROFILE TO CONNECT Wes- BASE. GC TO PLYWOOD OVER MIL a ES FIXTURE - ? PANELS TO KEEP THEM EXTEND BASE TO o STUD FRAMING. TYP. o .27 TOGHETHR, ATTACHED EDGE OF CABINET �, AT (2) LOCATIONS. *- FOOTPLATES TO WALL 11/ O'-0" A.F.F. n $■� \ 0'-0" A.F.F. 1 .h. u Al JI \ O'-0" A.F.F.AL " • FINISH FLOOR FI FLOOR� FINISH FLOOR� " 1 / 2-2 MIN. / 1'_9 5/8" / 1 -7UNTING WALL TO EDGE OF FRAME / FIXTURE ANGLE FOOT PLATE 1114 I NOT USED 12 ALL FRAME ELEVATION & SECTION WALL PANEL ELEVATION & SECTION WARDROBE ELEVATION & SECTION _ 3 >> \olr'' MTL STUD - - y - - DIAGONAL3RACE AT �� • • • *� iz?1 -7 TYP FRAMING, TYP. AT I ( 48" O.C. SEE 5/A6.0 • • 1 -0 1 TYP,-)e/ / AL.AMED . C END CONDITION I ( EDGE OF WALL T EDGE OF STUD - _ 5/8 GYP. BD. •, CENTER OF FIXTU E TO EDGE OF WALL TYP. 1�' UGHT FIXTURE AS r - -; . . �' OVER 2-1/2 MTL / � L.SCHEDULED. TO BE 1 STUD FRAMING TO V V 8 OF O'it: ATTACHED TO - I 3 r 1 PROFILE WITH CUPS) BE PTD. BLACK I SUPPUED BY I o 4S• - /4116h4\ I `�,, LIGHTING MFR. I _ SIN. • '--''SIN. - WARDROBE FIXTURE, TYP. SEE RCP WALL FRAMES FIXTURE > IV 8,0. CEIUNG 6 1/2" 6•� WARDROBE FIXTURE, TYP. / / HOLD / WALL BASE CONTINUOUS - TO BE INSTALLED TO 1" J-MOLD / STANDARDS INSTALL MOUNTING ANGLES. TO BE 5/8" GYP. BD. OVER MIL BELOW WALL FRAMES FLUSH WITH WALL PANEL PURCHASED BY G.C. STUD FRAMING. REFER TO '� h 3-5/8" MIL STUD FASTENED TO SHEET A.02 FOR FINISHES 1 TMP' " y 3-5 8" HORIZONTAL MEMBERS 1 -7 TYP. « / UNE OF SOFFIT ABOVE, G.C. TO INSTALL 1/4" FRY REGLET / / / 5/8 GYP. BD. OVER 5/8 " z SHOWN DASHED 1>1 REVEAL MOLDING AROUND FIXTURE EDGE OF STUD METAL BACKING PLATE - PLYWOOD SHEATHING OVER .- T O EDGE OF W A L L TYP. ., STUD FRAMING 5 8" GYP. 8D. OVER MIL Dennis Heath, Architect MIL. STUD FRAMING > / TO BE PURCHASED BY G.C. STUD FRAMING. REFER TO \ ., \/77I 24?0 Mariner Square loop 9'-3 1/2" A.F.F. ► r 4� ►, SHEET A.02 FOR FINISHES [(� � SEE 10/A6.0 i. ,��0) LINE OF BASE BELOW u... Alameda CA 94501 Y B.O. SOFFI ' 1 u Q I 8" 10" 2!_O 7/8" S PAINTED MDF CAP, BY G.C. / // / z LINE OF WALL BEYOND, I • MIN. MIN. TYP. m 3 z 5/8 GYP. BD. OVER MIL. a 5 SHOWN DASHED �I STUD FRAMING. REFER TO WALL PANS 6 Drawings and written material appearing herein constitute original W Co and unpublished work of tie Architect and may not be duplicated, WARDROBE FIXTURE TYP. > SH�Ef A.02 FOR FINISHES �W A LINE OF BASE BELOW > used or disclosed without written consent of the Architect f r cODH ARCHITECTS- 2010 WARDROBE FIXTURE, TYP. 1 FOOT PLATES FOR WALL PANELS TO BE INSTALLED TO 1" - I BELOW , " Q A Q C MOUNTING ANGLES. TO BE ' "V WALL END PANEL #3183 11-7" MIN. PURCHASED BY G.C. I EDGE OF W A L L T O 6" STRIP OF 5/8" P L Y W O O D N o . D a t e I s s u e I EDGE OF CABINET, TYP. OVER MIL STUD FRAMING. TYP. 05/28/10 100% SET NI fi" STRIP OF 5/8" PLYWOOD I (2) LOCATIONS.FRY REGLET OVER MIL. STUD FRAMING. I USE 8" MIN. 05/28/10 VT PACKAGE IMP. AT (2) LOCATIONS. I / AS ALTERNATIVE / AROUND FIXTURE.REVEAL 07/02/10 100% COMPLETE SET I N PURCHASED BY G.C. 07/28/10 LANDLORD SET 1 1/2"er-o' �'m'r-Q• �' -(r' 'I'=r-0" 08/13/10 PERMIT/BID SET I ill WARDROBE SOFFIT 11 ALL FRAME OUTER CORNER WALL PANEL OUTER CORNER _ 5 WARDROBE OUTER CORNER _ 2 Er N. NOTE: EDGE OF CABINET 1. REFER TO A0.2 FOR FINISHES AND RESPONSIBULITY SCHEDULE Li TO EDGE OF WALL TYP. y 2`-2" MIN. 2. GC TO CUT PANELS ON SITE ONLY WHEN CEILING HEIGHT IS LOWER THAN 7'-4". FOR THIS CONDITION DO NOT USE / 1'-7" TYR ) / WARDROBE o WALL WARDROBE I WALL FRAME WALL TO EDGE OF FRAME UGHT BEHIND PANELS 3. REFER TO INTERIOR INSTRUCTIONS FOR MORE INFORMATION EDGE OF STUD mom FIXTURE C PANEL FIXTURE T FIXTURE 3. REFER TO INTERIOR INRUCTIONS FOR FOOT PLATES SIZES. GC TO USE U-PROFILE TO CONNECT TO KEEP THEM TO EDGE OF WALL TYP. TOGHETER. ATTACHED FOOTPLATES TO WALL [ ,,...D , iw 3-5/8" MTL STUD FASTENED TO A 3-5/8' HORIZONTAL MEMBERS - - 1 - 1 - <:< - 5/8 GYP. BD. OVER CENTERLINE OF STANDARD 5/8" PLYWOOD OVER w PAINTED MDF CAP, BY G.C. . .. _ MIL. STUD FRAMING 2'-0" \ 5/8" GYP. BD. OVER 2'-O" z 6 � `> / / / / = E E E NO MIRROR AT THIS MTL STUD FRAMING NO MIRROR AT THIS I LOCATION LOCATION .' L L 0 WARDROBE TO WALL PANEL WARDROBE TO WALL FRAME ° >: Y�: .:..:::::.:::::::.:::..::...:::::::::::::::. :..:::..:::::. r :,:......:::::::... i ' J ` , - 2'_O" 2'-0 7/8" S. r c MIN. " 6" STRIP OF 5/8" PLYWOOD I OVER MIL STUD FRAMING, TYP. I I n �--� - - : • :D. OVER MT L N WALL END PANEL 1 u W A L L FRAME WALL A T (2) LOCATIONS. Project N o. 44122 FIXTURE PANEL WARDROBE C 3 WARDROBE STUD FRAMING. REFER TO 9 WALL BASE J 3 FIXTURE C 3 FIXTURE I SHEET A.02 FOR FINISHES _ FRY REGLET REVEAL MOLDING t: De. AROUND FIXTURE. TO BE Scale AS NOTED ',c_ WALL ", E CONTINUOUS PAINTED WALL REFER TO PURCHASED BY G.C. 3 BELOW ,U. FRAMES SHEET A.02 FOR FINISHES UNE OF BASE BELOW _-d U t 1 <-)6 5/8" GYP. BD. OVER MTL D r a w n B y: D M/AN 5/8. GYP. BD. OVER STANDARDS - INSTALL FLUSH STUD FRAMING. REFER TO /5/8" �: WALL FRAME ■ RE TYP. SHEET A.02 FOR FINISHES >, WffH WALL PANEL 5/8 PLYWOOD OVER g I ,. . ) NIL STUD FRAMING .: kt UNE OF SOFFIT ABOVE,A..:: �'. r.. y.,ill,.. < FOOT PLATES FOR WALL PANELS BELOW n SHOWN I SHED R:\HM\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220_A71.d 'O 1'-4" 5/8" GYP. BD. OVER MIRROR FIXTURE " METAL BACKING PLATE 0 .•' MTL / / MTL STUD FRAMING SEE 5/A6.5 -4 MIN. STUD FRAMING TO BE E / / WALL PANELS TYP. WARDROBE FIXTURE, TYP. - NO MIRROR AT THIS PURCHASED BY G.C. SEE TO BE INSTALLED TO 1 MOUNTING Drawing N o. LOCATION 5/8" GYP. BD. OVER 5/8" 10/A6.0 < 5/8" GYP. BD. OVER 5/8" ANGLES. TO BE PURCHASED BY G.C. N PLYWOOD OVER MTL. STUD PLYWOOD SHEATHING OVER FIXTURES AT SALES AREA FRAMING MTL STUD FRAMING . 0 WALL FRAME TO WALL PANEL CO WARDROBE TO WARDROBE A Q v` 0 „:,..,... BEAM TRANSITION _ io ALL FRAME INNER CORNER _ - WALL PANEL INNER CORNER _ 4 WARDROBE INNER CORNER _ 1 A7.1 WATER HEATER (APPROX. 75LBS.) SEE MECH. SPECIFICATIONS FOR ' EXACT MODEL AND MANUFACTURER I ■ ■ NOTE: WHERE REQUIRED BY LOCAL L .i� 11'-5' A.F.F. CODE, (2) 20 GA. STRAPS TO BE ry T,O, BRACKET MOUNTED 1/3 INCREMENTS B-LINE FIG. 63066 ANGLE MOP SANK FOR REFER ONLY. REFER TO A21 71(iliAl 1/2" WEATHER TREATED PLYWOOD BRACKET (TYP. 2) FOR QUANTITY AND LOCATION.. PLATFORM ABOVE MOP SINK i a - - _ .•----*---•..,,,`.• -T 9'-0" A.F.F.$j v .; " .O. CEILING Y ' 2-0 O.C.oC ', t FINISHED CEILING, TYP. • _ SECURE LOCKERS TO WALL NEAR • y PAINTED GYP. BD., TYP. • - - " n TOP AT END OF EACH ROW WITH - ___ - _ 71-6" A.F.F.�j - ( UNE OF i 1/4' TEK SCREWS 24 O.C. �= T.O, SHELF$ I C ADJUSTABLE CONT. ADJ, SHELVES, SURFACE / ' ''''''> / MTD. BRACKETS & HEAVY DUTY ( SHELVING US220 / " METAL STANDARDS MOUNTED ON 6-0 A.F.F. - 9 / �- METAL STUDS ,TYP. > _ - T,O, SHELF a - "-"'�"-"" WASHINGTON SQUARE gip / - o =j - CL OF5M P STRIP� A 9585 S.W. WASHINGTON SQUARE MOP STRIP MOUNT // ABOVE MOP SINK " SUITE H08 / 7-6 A.F.F. PORTLAND, OR 97223 / _______J T.O. SHELF - / - T CLASS: RED ti 4, 0" < - A.F.F. LOCKERS --• - 3'-0" HOSE MOP T.O. WAINSCOT \ < 0 ON I I I I a I I \ 1 X 6 FURRING STRIP AS NEEDED FOR LOCKER - � SINK SPIGOT • WAINSCOT, TYP, �► PORT, SHOWN DASHED \ SUP \ \ WP-1 - ." SEE 2/A21,,, /, , \ , �/ MOP SINK '� • CERAMIC TILE BASE, TYP. • ' . o-o A.F,F. CT-1 FINISH FLOOR Y 0 ELEVATION 0 ELEVATION 0 ELEVATION 4,40 FINISH FLOOR I V8-1 • I 1/2'=t-0' -_ 1I2'=r0•JANITOR ROOM ELEVATIONS JANITOR ROOM PLAN 6 EMPLOYEE LOCKER ELEVATION I_38 :t 3 Ipill■ i■.,., , 0.16 (..--:1 NOTES: _ .N , NOTES: NOTES: 1. G.C. TO PROVIDE BLOCKING AS NEEDED. SEE (1.--0- -2 1. PROVIDE GROMMET EVERY 4' OF DESK MIN. 2 . -2 �' 1. G.C. TO PROVIDE BLOCKING AS NEEDED. SEE (1-E") WOOD VENEER :::,:i.,:.. ::.:. ::.:.,:::.: '- 1. G.C. TO PROVIDE BLOCKING AS NEEDED, SEE 10 WOOD VENEER �"`A8 0 2. MIL. BLOCKING BEHIND GYP. BD. A�'i _ �,_ _ 2. 3 CEILING MOUNTED SECURITY CAMERAS IN ADMIN. ROOM 2. MM. BLOCKING BEHIND GYP. BD. CABINET DOORS 2. MTL. BLOCKING BEHIND GYP. BD. A� CABINET DOORS ■ ALAMEDA, CA • 3. FINISH COLOR OF COUNTERTOPS & CABINETRY TO BE �- 3. FINISH COLOR OF COUNTERTOPS & CABINETRY wv-1 (f.e ' : : ,,, rr,:. (COORDINATE W/ H&M). 3. FINISH COLOR OF COUNTERTOPS & WV-1 _ SELECTED BY TENANT. • • TO BE SELECTED BY TENANT. ::.::.:<:;<:;;:»: :,.:i:<>>,I:::.>::<:: TO BE SELECTED BY TENANT. ::.:,:%::,:::::<,::f,,,,,::::.:::::: '� cP 4. G.C. PROVIDED MILLWORK WILL REQUIRE SHOP DRAWINGS 3/4 BACK 3, 1/4" BACK PANEL LAMINATED TO MATCH, W. 5/8 MOUNTING 3/4 BACK k ......... - !............«........ RAILS. 4. G.C. PROVIDED MILLWORK WILL REQUIRE SHOP 4. G.C. PROVIDED MILLWORK WILL REQUIRE SHOP '. OF (:)‘‘ ''''' SUBMITTED TO TENANT AND ARCHITECT UPON AWARDING OF PANEL' PANEL. 4. 3/4" DMDER PANELS AS SUPPORT FINS LAMINATED TO DRAWINGS SUBMITTED TO TENANT AND ARCHITECT ADJUSTABLE = DRAWINGS SUBMITTED TO TENANT AND ARCHITECT ADJUSTABLE _ CONTRACT. _ MATCH ON EXPOSED SIDES. UPON AWARDING OF CONTRACT. SHELVING '� UPON AWARDING OF CONTRACT. f SHELVING `i ALL VISIBLE f - PL-1 >:<>iy::::-«::;::>:::;_;:u -'» :>„ PL-1 p ALL VISIBLE SURFACES • SURFACES tt It 1 MTL STANDARD > Mlt. STANDARD > PROVIDE GROMMET PL-1 PL-1 - • :<::::/fias�ii;;:%>rs>;>.,:;%::,:,::.�:::::i:.r.,:. �i:iii:-i� EVERY 4' OF DESK ii:.i ii:::<.:.iii:.:i:<.iiii,,::::<iii: TILE BACKSPLASH 2 ADJUSTABLE SHELVING, TYP. ''� ADJUSTABLE SHELVING, TYP. �._1 T TILE BACKSPLASH MIN. (2) MTL. STANDARD > '- WT-1 '� - HORIZONTALLY MOUNTED HORIZONTALLY MOUNTED DUPLEX t '" MTL. STANDARD i DUPLEX -__ __1�� `�, SCRIBE r '"' HORIZONTALLY ii;;.;.::.:i::i,. �L 4A :E ;::• s o 7 SINK 2'_1" DNT s Dennis PL 1 Mariner Square loop . 2-6 PL-1 2-6 t i,\I t _1 A, ■� Alameda CA 94561 '`- 2'-10" A.F.F. �,- - 2' 0• F.F, �. ' aik 2-9 A.F.F. - - -.. ... ...,: ........ ..... :.. :i:<,;>;:::>• ii:i::::<,i::i ;::i::.ii:•: _r9;cJERTOP T.O. COUNTERTOP :: :::-:. . ' : T.O. COUNTERTOP T.O. COUNTERTOP O N 4" 1'-0' - 4" 1`:... is 3/4i DRAWER - �' i� to PVC NOSE ii. Z-> I=--- \ PVC NOSE �■ ca 3/4 441 8. LOCKING CYLINDER Orstia s aid 'Hilton material a appearing herein constitute original CUTOUT IN EVERY SUPPORT I PL-1 4' / � �, 9 P P 9 9 : 3/4" PLYWD. ANGLE and unpublished cork of the Architect and may not be duplicated, PROVIDE 6" F.R.T. PLYWOOD CABINET DOORS INTERIOR used or disclosed without erittea consent of the Architect BLOCKING CENTERED AT 28• (TYP.) PL-1 >.::»::::::;: :::>-»> MTL. CUP WOOD VENEER CABINET DOORS > (DOH ARCHITECTS- 2010 N P-LAM OVER 1 1/2" , INTERIOR • z 4 THK PLYWOOD SUPPORT ::> :,u.; .. WV-1 = REMOVABLE PANEL W/ I E V E R Y 3'-O' • a, WOOD VENEER FINISH • ---- Q A Q C PL-1 ADJUSTABLE SHELVING I ADJUSTABLE SHELVING �" e N 1 WV-1 N o . D a t e I s s u e BASE WOOD VENEER BASE 3" wv-1 = PROVIDE 1 1 2 X 1 1 I 05/28/10 100% SET 2 ANGLEFASTENED TO SLAB ,.:::::::..........:......................._. .. . . ....................................:.... : 1 :...::::..::.,:,::..::::.,::::i::.iiiiiiii:::iiii;.:i:::::i:: WV_1 \.�' \ L • O'-0" A.F.F. .1 I 0'-0" A.F.F. "', !l I 1 O'-0" A.F.F. , A X.t I O•-0" A.F.F. " , 17 \ 1 I 05/28/10 VT PACKAGE • FINISH FLOOR SEE PLAN R Y FINISH FLOOR 3" FINISH FLOOR FINISH FLOOR t p ©R 07/02/10 100% COMPLETE SET SEE FLAN OR `f'' S'EE PLAN OR IN LL TAE W 11 TYE TYPE 07/28/10 LANDLORD T SET ROOM CABINET SECT. ro-°• 1 11 ADMINISTRATION ROOM CABINET SECT. I fermi I 8 LOUNGE ROOM CABINET SECTION 11'04' I 5 LOUNGE ROOM SINK SECTION las4-°'" 08/13/10 PERMIT/BID SET NOTES: 10 5. 3/4" DMDER PANELS AS SUPPORT FINS LAMINATED TO NOTES: ' NOTES: 1. G.C. TO PROVIDE BLOCKING AS NEEDED. SEE A6.0 MATCH ON EXPOSED SIDES. 1, PROVIDE MATCHING FILLER PANELS AT BASE UNITS TO 3. 1/4 BASK PANEL LAMINATED TO MATCH, W. 5/8 REFER TO ELECTRICAL n 1. G.C. TO PROVIDE BLOCKING AS NEEDED. SEE 10/A6.0 2. MTL BLOCKING BEHIND GYP. BD. �,• SCRIBE TO WALL. SECURE AS REQUIRED. MOUNTING RAILS SHEETS FOR RECEPTACLE n CO-1 2. MIL. BLOCKING BEHIND GYP. BD. 3. FINISH COLOR OF COUNTERTOPS & CABINETRY TO BE 6. G.C. PROVIDED MILLWORK WILL REQUIRE SHOP DRAWINGS 2. 3 CEILING MOUNTED SECURITY CAMERAS IN ADMIN. ROOM 4. 3/4" DMDER PANELS AS SUPPORT FINS LAMINATED TO LOCATIONS DUPLEX OUTLET > 3. FINISH COLOR OF COUNTERTOPS & CABINETRY TO BE SELECTED BY TENANT. SUBMITTED TO TENANT AND ARCHITECT UPON AWARDING (ORDINATE W/ H&M). " " OF CONTRACT. - MATCH ON«EXPOSED SIDES. N� SELECTED BY TENANT. 4. 1/4 BACK PANEL LAMINATED TO MATCH, W. 5/8 , CONTACT: GLENN STRABLE H&M L.P. AND SECURITY 5. PROVIDE 2 DIA. GROMMET EVERY 4' OF DESK, TWO (2) �, 4. G.C. PROVIDED MILLWORK WILL REQUIRE SHOP DRAWINGS MOUNTING RAILS 7, PROVIDE 2 DIA, GROMMET EVERY 4 OF DESK, TWO (2) MANAGER 415-341-3585 MIN. LOCATE UNDER ELEC. RECEPTACLE, TYP. SUBMITTED TO TENANT AND ARCHITECT UPON AWARDING OF MIN. LOCATE UNDER ELEC. RECEPTACLE, TYP. BACKSPLASH • �. CONTRACT, EQ. EQ. EQ. EQ. EQ, EQ. EQ. COUNTER TOP I • / / / / / / / / / CERAMIC TI BACKSPLASH CONT. ADJUSTABLE DUPLEX AT COUNTERTOP _ _ WT-1 WORK SURFACE SHELVES, SURFACE MTD. 0 -....._../ \,._,.� G-3 AND BACKSPLASH STANDARDS & BRACKETS ri-\) PL-1 _ PL-1 �� DUPLEX OUTLET WITH WHITE WOOD VENEER CABINETS N.....-.., METAL COVER PLATE-CENTER PAINTED GYP. BD. • ON COLUMN, TYP. V.I.F. i WV-1 • PAINTED GYP. BD. HEIGHT BY COLUMN MIRROR REFRIGERATOR 2 EQ. 2 EQ. 2 EQ. 2 Q. AND SPECIAL FIXTURE c c / 3'-3• �/.... ADJUSTABLE SHELVES \ PAINTED GYP. BD. ADJUSTABLE SHELVES : T V = PL-1 PL-1 i' io 0 4 3/4" PAINTED �\ N WOOD BASE • COU i P Project N o. 4412 2 I PAINTED d I e�� . CO-1 • - = GYP. BD. WORK SURFACE DUPLEX AT COLUMN © S c a I e AS NOTED PT-2�, AND BACKSPLASH _ _ ua = ,,. _ - • MICROWAVE ° ° PL-1 ° ° -, -7\ \ ,,- • • . . �a • • :. cv " Drarnt3y: DM/AN q•_=rt:. i T 21-10" A.F.F.�j REFER TO ELECTRICAL " " _ T.O. COUNTERTOP`f E • REFER TO SHEETS FOR RECEPTACLE \ 3 X 6 TILE • I ,.� ADA COMPLIANT cr ELECTRICAL SHEETS LOCATIONS ° ° j WT-1 c c \ \ \ f F .;., 2 '' FOR RECEPTACLE ° ° o y SINK AND FAUCET LOCATIONS • / DUPLEX OUTLET __--------- ' *�= • CABINET BY G.C. R:\NM\Projects\201D_Projeets\44122 Washington Sq\Drow,ngs\CD\US22O.A80.d - 1 WITH WHITE MTL. 6 N, PL-1 oc° • �- COVER PLATE / '1 • �_ \ " 'r Drawing N o. • CP-1 / 8I-1" / BASE CABINET BY G.C. COUNTER TOP • '� 30 MILLWORK - V.I,F. VB-1 MIN. CUR. BASE DETAILS 11 PL-1 CO-1 REMOVABLE PANEL ELEVATIONS WV-1 VB-1 I �,,_,,, CP-1 DUPLEX AT TILE BACKSPLASH WV-1 AND SECTIONS Q SIM. . PAINTED GYP. BD. O 'D 3/8"4-0* 3/8'=1-0" 11/2""=1-0" 3/8'4-0' T. MEETING/SECURITY ROOM ELEVATION _ 10 ADMINISTRATION ROOM ELEVATION 7 ELECTRICAL OUTLET MOUNTING DETAIL _ 4 LOUNGE ROOM ELEVATION _ i A 8 .0 ,- NOTE: 7-------HANDRAIL FINAL FRAMING AT ESCALATOR TO t9D- BB BE COORDINATED WITH VERTICAL STAINLESS STEEL DECKING TRANSPORTATION MANUFACTURER SHOP DRAWINGS I 1 A 711/4 ili ______________M••••••••■•1111.0---- --- Ellal ---7 \ 38 4.7 eir II r . . .0.,. fir' j BALUSTRADE SKIRT 1 -•a\ ESCALATOR STEP _., I I I \ 1.€11 1-2 3/11' y 25-7 1/4• y r-2 3 e.. is r U S 220 STRUCTURAL OPENING .. if--- { ESCALATOR TRUSS WASHINGTON SQUARE 7.-5• y 2S-2• y r-s• 9585 S.W. WASHINGTON SQUARE RASH TO 491 ate GYPSUMBOARD FINISH ON 1 BOTTOM OF GYPSUMBOARD METAL STUD FRAMING i SOFFIT WHERE OCCURS SUITE H08 /^2 5/8" BELOW ESCALATOR, EXTEND : - - PORTLAND, OR 97223 A GYPBOARD FINISH TO TOP OF BALUSTRADE Cam: RED I I 1-8 W 17, i Z ESCALATOR BALUSTRADE DETAIL 11/T=1-O J 4 __ __...._ _ _ w e• NOTE DRAFT STOP TO BE INSTALLED 7-8 3/b• 5 p y SURROUNDING THE UNENCLOSED OP G OF ii.A9.Ob ESCALATOR 2 (-4--. 1 STRUCTURAL � ESCALATOR. REFER TO RCP FOR TION �..� "UP • OPENING (--2.-`_ 1 ; fi" 20 GA MIL STUD '. - 16" 0.C. Z i. TYP �...�-IYp . 4 I Illil■ "Ill , .........., , ,, , ,, . , , \ _ ` '� CEILING AT S AREA , 1 . ri �i1 STRUCTURAL - - ��e A,\' ' z ESCALATOR 1 ,,, **5 3 • ' 1 , c t. = OPENING " J 1 ,t �,,,/1 i"DOWN ,� -ii , /111411\ ■ .. " _ Q' , ': 2 1/2" 20 GA MTL STUD FRAMING - �-3 .i r" 1 fi" O.C. ATTACH TO 6" MIL STUD W/ ALAMEDA, CA ' 11 2- 8 MINIMUM SCREWS ® 1 fi O.C. rfs , if ' 011114 4'OF 010?) 1\- - — — — — E — — — - -113 (// \ ESCALATOR BALUSTRADE 5/8" �'. BD. 1 q 0 A91O SIM . STRUCTURAL GLASS GUARDRAIL : -: r< B.O. DRAFT STOP • 1 I 3 1/2m Z 1/4" _ / ESCALATOR PLAN - LEVEL 2 I 1'4■0t 7 SMOKE DRAFT CURTAIN DETAIL s 3 Dennis Heath, Architect 2470 Mariner Square Loop Alameda, CA 94501 8" e ALL GAP AROUND FLOOR PLATE VERIFY B B AA WITH ELASTIC COMPOUND PER W/MFR MFR INSTRUCTIONS Drawings and written material appearing herein constitute arigiuI and unpublished work al the Architect and may not be duplicated, ESCALATOR FLOOR PLATE used or disclosed without written consent of the Architect __ — — — — : — — — :: \ 38 FINISH FLOOR ®DH ARCHITECTS- 2010 III – !';': • " QAQC Immo il ,.......... No Date Issue I S FINISH FLOOF iIt `llE c' .,►,.,•,,.•,�,,,.-1-::_ Zeal .• 05/28/10 100% SET ,' ■ ■mow= 05/28/10 VT PACKAGE r _,ffin ° 07/02/10 100% COMPLETE SET = SEISMIC RESTRAINTS AND '- 1 07/28/10 LANDLORD SET BOLTS BY ESCALATOR 08/13/10 PERMIT BID SET I c, MANUFACTURER PERMIT/ BID 8" ( 14'-3 1/4" MIN PIT SIZE 14'-3 1/4" MIN PIT SIZE ;" (�) �' _`__- N 7/ A- 1 STRUCTURAL ' STEEL BEAM, SEE VERIFY W/MFR VERIFY W/ MFR OPENING STRUCTURAL DRAWINGS I O 11 1/4" N ;. = z-. — : \ FACE FINISH OPENING ABOVE / i W j ____ i }„...„,..„:„....,:,:s-„,,,„:::::,:,-;.--1-1 \ / .�___,.,„. _ ,---- ESCALATOR TOP BEARING DETAIL 1 v 1 2 1 i I / I f W = Z I; re' ) Al AI •— ESCALATOR 2 .a M 3 I A9 O� ``' \ "UP" r I \ / :":1 �. a- - ESCALATOR FLOOR PLATE r ; °r ::— — _ — — — \ / k ;.... .r r . FILL GAP AROUND FLOOR PLATE -\ / \ �,�, WITH ELASTIC COMPOUND PER oo t ; f it / 1 .� I ( W MFR INSTRUCTIONS \. N3 i �, v—, ; �•.., i f ESCALATOR 1 \ I FINISH FLOOR /1,1\ ":4- -.1- mr t `j "DOWN" / \ 77 ESCALATOR PIT SHOWN DASHED, . I TYP►, REFER TO STRUCTURAL a" Protect N o. 44122 A9.Ob ., - P ,� \ - I DRAWINGS. ALL DIMENTIONS TO �r 0 ]- FINISH FLOOR xx ---Kx ..........: rE ,�, �:: / I \ 'a BE COORDINATED WITH ESCALATOR acs .-.3 , = 1,7T N\ I VENDOR g" L g :i m 1/ S c a l e AS NOTE D in `--�TYP ----11 1/4 .. / \, r•" �,. :.ii,E11 ESCALATOR SUBFRAMING co / LINE OF SLAB OPENING ABOVE ''''" r 1== - . . Et: - B 'I (� VIBRATION ISOLATION — ■:■ - - - - ■ - - ■ - - <.I [ SUPP T BY ESCALATOR cp all 0 18' HIGH SMOKE DRAFT CURTAIN R:\HM\Projects\2010_Projects\44122 Washington Sq\Drowings\CD\US220J�90a.d f. Q AROUND OPENING ABOVE, REFER TO RCP co FOR SOFFIT HEIGHT AND DETAIL 10/A6.Oa FACE OF PIT OPENING FOR DRAFT CURTAIN DETAIL BEARING PLATE EMBEDED IN Drawing N o. CONCRETE BY C.C., COORDINATE ESCALATOR PLANS 39'-01 5/8" W/ESCALATOR MFR 11 1/4" - Ni PIT OPENING SIZE > AND DETAILS _ (NTS) VERIFY W/MFR 7. veger-0o• 1 Inirdi-0" _. ESCALATOR PLAN - LEVEL 1 5 ESCALATOR BOTTOM BEARING DETAIL - i A9.0a a. . , NOTE: FINAL FRAMING AT ESCALATOR TO STRUCTURAL GLASS GUARDRAIL BE COORDINATED WITH VERTICAL . BEYOND, SEE DETAIL 2/- Y 3'OAL. . (il? B B A TRANSPORTATION MANUFACTURER 7111/&/I/ SHOP DRAWINGS ,.. -- NOTCH EDGE OF GLASS AROUND ,�..-� ' ESCALATOR BALUSTRADE Qqf ESCALATOR HANDRAIL AND 1.1.1i 10 -2" A.F.F. (MEZZANINE) BALUATRADE, SEE DETAIL 4/A9.0a B.O. CEILING ii 7'-5" 25'-2" 7'-5" r 3 7/8" MAX —1-,, J-- / / /- / / 1'-7 3/16" r-s- 1 STRUCTURAL GLASS r''/ / / TYP - GUARDRAIL - ►• J- rTh rik US220 /II— - 7 1/2"--- 6" ---- r SQUARE / /`: •;I,Zr ;- ESCALATOR STEP 9585 S.W. WASHINGTON SQUARE ♦ S� Arab, 1 ' 1 �j o'—o" SUITE H08 '� * r ' 1 ) Y FINISH FLOOR M .. .�> PO 223 _ / s FL o (ME/Z.) � --- .;iil= RTLAND, OR 97 14'-0" . ti — ��■ Ili.. / ;. CUSS. RED T T . \FINISH FLOOR (MEZZANINE) iiiP / / i TOP OF FLOOR BEYOND " , / TOR WELL 10'-0" A.F.F. �, — -- -w:`►. . '/ / !=- R ESCALATOR TRUSS B.O. CEILING �.� FACE OF ESCALATOR WELL BEYOND I - n - EDGE OF STRUCTURAL OPENING / /c M i. / c ESCALATOR 2 "UP" SMOKE DRAFT CURTAIN �, / o 7 1 2' / PIT FOR "UP" ESCALATOR / \'� 1/21=1-0" 4iI igiV , ,-- GUARDRAIL AT ESCALATOR _ 3 1:::::1 ,11 ��-- . / ►; A9.0 TH co./ / 4 gift .-3 0'0" / ®� • ALAMEDA,+CA •do>)\ --® .: .: _L; Ala . FINISH FLOOR (FIRST LEVEL 1. 3 •LEVEL) �. < 1 x 1 BRUSHED STAINLESS itht (.1 I ,n STEEL RAIL CAP C OF 00 / _1 / t CONTINUOUS MEMBRANE SS-1 \ ° WATERPROOFING AROUND PIT, TYP < 1/2" LAMINATED GLASS SALES PIT FOR 'DOWN" ESCALATOR 5/8" GYP. BD. OVER MTL BEHIND, SHOWN DASHED STUD FRAMING 14'-7 9/16" MIN (----5 3/4" / // ALIGN TOP OF TRIM ANGLE ESCALATOR 1 "DOWN" * VERIFY DIMENSION WITH MANUFACTURER VERIFY W/MFR W/TOP OF FLOOR FINISH BEHIND, SHOWN DASHED FINISH FLOOR CST-1 1" x 1" x .062" BRUSHED STAINLESS STEEL TRIM ANGLE SS-1 - I ESCALATOR SECTION 1/4•111-0"t-y' 5 $O'-O• FINISH ��R tM EZZ. x -K n x% � Dennis Heath, Architect 24/0 Mariner Square loo p� ' BASE SHOE, ATTACH TO SLAB EDGE P ., ANGLE PER RAILING MFR INSRUCTIONS A l a m e d a, CA 94501 .�J ,.: . STEEL ANGLE EDGE, SEE ...,70 STRUCTURAL DRAWINGS, IYP. 2 5/." ESCALATOR WELL CC BB AA ►� � Drawings and arittes material appearing herein constitute arigiaal ' and anpublished 'ark of the Architect and mug not be duplicated, al11111111111111 STEEL BEAM, SEE used or disclosed rithout vriltea consent of the Architect STRUCTURAL DRAWINGS cUDH ARCHITECTS- 2010 10'-2" A.F.F. (MEZZANINE) ()ADC B.O. CEILING No . Dote Issue 7-5 25�2 7-5 " ' " < 5/8" GYP. BD. OVER 05/28/10 100% SET -/ / )' A- MTL STUD FRAMING 2i: � 05/28/10 VT PACKAGE , STRUCTURAL GLASS (P-2-- 2 l l 1'-7 3/16"----,,GUARDRAIL - TYP * ` \ ! y 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET 6" �7 1/2" 11/2' 1-0' 08/13/10 PERMIT/BID SET / y DETAIL 2 GUARDRAIL T 1.3;, oils A9 C * 13‘e.., C 14'-0" , < STRUCTURAL GLASS ,I� v� ;. . : L_____ - _� GUARDRAIL, SEE FINISH FLOOR (MEZZANINE) :® �(71 j -- op 11- I DETAIL 2/- , FINISH FLOOR%," � ��" \ s: �, CST-1 10 -2 A.F.F. to �_ -:�i N � * mod,, �'�---i. - - -- - - - - - - - - - 14,_0" • B.O. CEILING r �� 00 FINISH FLOOR t ''� T` - .� FACE OF ESCALATOR WELL BEYOND 41. 25 s „,ESCALATOR 1 "LIMN" " \ \ < EDGE OF STRUCTURAL OPENING i ° \ • • 3-5/8" MIL. STUD PIT FOR "DOWN" 7 1/2" °' \ SMOKE DRAFT CURTAIN - FRAMING ESCALATOR \ • . 1 �. \ • / / - 0 II , A . <-5/8" GYP. BD. OVER Project No. 44122 , " T 0 0 \ t MIL STUD FRAMING PT-2 / ' ' Si I S c a l e AS NOTED FINISH FLOOR (FIRST LEVEL) %Ill— a 02 - r'► 0 .. CONTINUOUS MEMBRANE L? ;d. \ WATERPROOFING I DraninBy: DM/AN AROUND PIT, TYP • r IXHT COVE, SEE E 1 b - DETAIL 4/A6.1a, SIM 10'-2" A.F.F. . . , I Lit 1 5/8* GYP. BD. OVER -1\---- PIT FOR "UP" ESCALATOR BEYOND V B.O. CEILING R:\HM\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220J190b.d E. 14'-7 5/8" MIN MTL STUD FRAMING SHOWN DASHED 0 9'-10" A.F.F. 8.0. SOFFIT "� Drawing N o. 5 3/4' --�/ VERIFY W/MFR .I * VERIFY DIMENSION WITH MANUFACTURER ESCALATOR 2 "UP" BEYOND 1/2" THICK TEMPERED GLASS SMOKE _ ESCALATOR SECTIONS DRAFT CURTAIN SURROUNDING AND DETAILS T ESCALATOR WELL SEE DETAIL �,,..--� 10 A6.1 b 8'-8' A.F.F. / , -45 B_n_ DRAFT (URTAlN . 2 1I4'=�-0' f=1-Or ESCALATOR SECTION _ 4 DETAIL AT GUARDRAIL/SOFFIT - _ 1 A9.Ob . • 5/8" TYPE X GYPBOARD OVER C-H `t 7/11/&/11/ STUDS W/1" GYPBOARD LINER \ 1. GC TO PROVIDE ADEQUATE UGHTING TO MAINTAIN MIN 5 FOOT-CANDLES ILLUMINATION AT PIT FLOOR PANELS PER UL ft U469 I ACT-1 2. GC TO PROVIDE PIT ACCESS LADDER, LIGHT SWITCH, UGHT, AND GFCI-PROTECTED UTILITY OUTLET WALL BASE AS SCHEDULED (-9- 3. GC TO PROVIDE 8" X 8" BLOCKOUT FOR HYDRAULIC OIL LINE AND 8" X 8" BLOCKOUT FOR ELECTRICAL MEZZANINE N'N\,..... A9` SIM 4 CONDUIT FOR EACH ELEVATOR; VERIFY LOCATION WITH ELEVATOR CONTRACTOR FLOOR PROVIDWIUBRJsN:DPOCRRFURIDE E 1-HOUR N RATED. . 4. GC TO VERIFY PATH OF OIL LINE WITH ELEVATOR CONTRACTOR CAULK ELEVAT GYPBOARD SHAFT RAIL FASTENING AT 12'-0" MAX VERTICAL WALL, UL IU469, 4 7'-0" A.F.F. 5. GC TO COORDINATE LIGHT FIXTURES AND UTILITY OUTLETS LOCATION WITH ELEVATOR CONTRACTOR CST-1 SPACING THROUGH TOP OF HOISTWAY (BY NP, ..,_ .A...„„ 7.-6.. A.F.F. _ CAN, IF SPACING BETWEEN SUPS.974AXS T.O. OPENING 6. FINAL FRAMING AT ELEVATOR TO BE COORDINATED WITH VT MANUFACTURER SHOP DRAWINGS. CANNOT BE MAINTAINED AT 12 , B.O. CEILING PROVIDE INTERMEDIATE SUPPORT BEAMS 1/2" REVEAL IN 7. GC TO PROVIDE ELEVATOR GUIDES SUPPORT PER MANUFACTURER SHOP DRAWINGS. OR CONTINUOUS VERTICAL STRUCTURE BETWEEN PANELS > 1 BETWEEN FLOORS (BY GC}. REMOVE 1012'" A.F.F. s OVERHEAD HOIST BEAM AFTER ELEVATOR ...... di STAINLESS STEEL IS INSTALLED IF OVERHEAD CLEARANCE B.O. CEIUNG v US220 SIDE PANELS — 4 . .: : < STEEL CLOSURE CANNOT BE MET I - PLATE WASHINGTON SQUARE - I 9B,.,�, DRAIL ELEVATOR NOTES SS-1 - - Z 9585 S.W. WASHINGTON SQUARE HOUSE \ SUITE H08 CAB DOORS > I ---� PORTLAND, OR 97223 rn V 1. GC TO PROVIDE 8"x16" BLOCKOUT FOR HYDRAULIC OIL UNE AND ELECTRICAL CONDUIT FOR EACH CEIUNG 1 ("9".\ ELEVATOR; VERIFY LOCATION WITH ELEVATOR CONTRACTOR : 1 CLASS: RED AO 2. GC TO VERIFY PATH OF OIL UNE WITH ELEVATOR CONTRACTOR : °I N. 3, GC TO PROVIDE 110 VOLT, 20 AMP DISCONNECT SWITCH FOR EACH OIL COOLER MOTOR I'K7 AY 18'-4' A.F.F N °I 4. GC TO PROVIDE ADEQUATE UGHIING TO MAINTAIN MIN 10 FOOT- CANDLES ILLUMINATION AT MACHINE D FLOOR ca (E) BEAM, S.S.D.SROOM FLOOR > o ELEVATOR SALES 0'-O" A.F.F. \ \ k ("i" v CAB 5. GC TO COORDINATE UGHT FIXTURES AND UTILITY OUTLETS LOCATION WITH ELEVATOR CONTRACTOR .t- FlNISH FLOOR BUMPER RAILS SIMA- / ''' 4 SS-1 + I I I I øflTh , 141_OwA.F.F MEZZANINE tl S. � LE CAB INTERIOR ELEVATION _ 12 ELEVATOR MACHINE ROAM NOTES 9A DETAIL AT SHAFT WALL 3 ,�. 4:l if di ... 110 . (t"."; CAB LIGHTING _ < GUIDE RAIL DISCONNECT, BY GC EQ. 2'-0" EQ. `` • AZAMEDq RESCUVATOR / /- 2, 10-2" A.F.F �,a, OIL COOLER MAIN POWER SUPPLY _ _ 1. B.O. CEILING cop GO CSCSib. ELEVATOR CAB DISCONNECT, BY GC DISCONNECT SWITCH a z' `� � a , , POSITION ® FIRST w\ LEVEL o < FLOOR TILE. PROVIDE FLOOR —I 4-- ..A..k 8'-:0" A.F.F. DEPRESSION TO RECEIVE ,-- B.O. CAB CEIUNG lir N - TILE AS REQUIRED I T-0" A.F.F. \ CST-1 < TWIN TELESCOPIC V i� MALL ELEVATOR I HYDRAULIC JACKS T.O. OPENING r • // _k \ N R-- —m ' 1'-6" PIT LIGHT SWITCH, Dll MACHIE • 42" MIN CLR _\ III III MIN, �� BEHIND BY GC ROOM �' �' (,.) III III III III SALES Z �. \ -o m— a 1= _ - W� z 4. I I I � Dennis Heath, Architect LIGHT FIXTURE z cal CO = _ v, a * I EQ. EQ. EQ. CCTV CAMERA W POTECTIVE - / I I Mariner Square loop WW N L J •rn CAGE, BY GC, _ = I Alameda, CA 94501 / / / SEE MEP DWGS I I STAINLESS STEEL < CONTROL STATION PANEL Ej Z WALL MOUNTED TYPE DOOR & PANELS > ABC FIRE x ,III _ _ I EXTINGUISHER BY GC --\ —... ...J 0'_0. \ �- < STAINLESS STEEL SIDE _ 41:1 r7-- \ FIRST LEVEL = PANELS SS-1 GA OUTLET, BY GC a 0 0 0 f I I i SPRINKLER HEAD Drowings and written material appearing herein constitute original • L . re . = # BEHIND and unpublished cork of the Architect and may net be duplicated, UGHT SWITCH, BY GC a 3 `' `` 1 P STAINLESS STEEL BASE \ _ < �' S PANNEL SST POLISHED I — I HEAT SENSOR used or disclosed without written consent of the Architect SS-1 MIRROR #8 FINISH BEHIND BY GC 0 D H ARCHITECTS- 2010 V FIllr� or 0 0 0 I � _ I O'-O" A.F.F. ROOM 1-HOUR DOOR, SEE nESSED DOWNUGHTS, N — < PR ACCESS LADDER DOOR SCHEDULE \ . I I I BEHIND BY GC Q A Q C FINISH FLOOR -\-- .. rr NON-GA OUTLET 1 No . Date Issue 8'-11» a III 0 0 0 III BEHIND BY GC, / / III III SEE MEP DWGS 10P-9 1/4" 05/28/10 100% SET \ � I®' / VERIFY W IMFR. / 05/28/10 VT PACKAGE GFI OUTLET BEHIND BY GC, / 07/02/10 S 100% COMPLETE SET SEE MEP DRAWINGS 07/28/10 LANDLORD SET �/�'=T-� 3/$'='�-0' 3/$'=�'-(}�' 3/8'='�-0' 08/13/10 PERM IT/BID SET CAB INTERIOR ELEVATION _ ii ELEVATOR MACHINE ROOM _ - 8 CAB FLOOR PLAN & RCP 5 HOISTWAY SECTION _ 2 1 " 10-2 A.F.F. 10'-9 1/4" CLEAR HOISTWAY a) ID B.O. CEIUNG ; is R r r r - — 38 = - - -W— ; 38 I I I _ II 11�I��I1 d i,i®ii 1, 1®i iiiI I I I ,1 9i�i, !a,i1ili�iiiii i i ii�iii i®i iiiiil I iili i®iii I�!���I\ \ --i is ...„Q„ 1-- 1 '1/4 n— --7 \ 15— _Qr. ..A$ 7-OkFF. to I— 111 ....,,,, T.O. DOOR o - 2 ¢>_ N , ›.. 2 : ¢ HALL SRN >v ¢ r---1 rY cn i r \ •.r,• cr cn • �- --= \ GYP. BD. WALL > R o = ELEVATOR I ° = ELEVATOR m «3 _ _ PT-2 ^I t� p _J cr CAB F- s CAB 1 ce ELEVATOR BUFFER, TYP z _ C-4-J LIGHT W/ PROTECTIVE x BACK OF o ca 4- o-- U, SALE o c. _ .- SALES CAGE (NIEC) fi o HOUSE ..I R Al .,I ► p Project No. 44122 I cn mot- —= cc� o • 1 = C.' I 11 10 1 • 10 HALL. CALL BUTTON >: GFl OUTLET {NIEC) = r• -Na- _ =-- r• Scale AS NOTED I'I t_ \ � \ \ .a1- \n_ -0- I A EN m 41 KW.Mr \- ►� v i 0 n_ -JOL L- v-1 ft E ! iii v I ! Imo!! !� V I. I '!!!,iiiI!i!1!��!!! ii.! !i ll illii v D r a w n s y: DM/AN E WALL BASE L ,. O WB-1 ELEVATOR GUIDE, •YP I I R:\HM\Projects\2010_Projects\44122 Washington Sq\Drawings\CD\US220J1914 HYDRAULIC JACK AT BOTH SIDES o'-o" A.F.F. �' I 9'-5 3/4" PLATFORM 9'-5 3/4" PLATFORM — ELEVATOR PIT LADDER, BY GC FINISH FLOOR " / / Drawing No. 0 10 -9 1/4 CLEAR HOISTWAY 1'-7" 101-9 1/4" CLEAR HOISTWAY 1'-7" ELEVATOR PLANS, SECTIONS,r / / VIF / / VIF il AND DETAILS N Q O I 1/2"=?-0�' 3/$"=f-0" 3/8"=r-0" 3/8'=Y-0' ELEVATION AT ELEVATOR 10 HOISTWAY PLAN 7 ELEVATOR PLAN - LEVEL 2 4 ELEVATOR PLAN - FIRST FLOOR i A9.1 1 ' ....... .. - '- ' . .. ' '-- '''''''''''''' '7:.::"--;' ''''l'I'1:::77::,:7:,:::,':,:::'!::::::7,',—'77,-'''''',:':,,''''7::'''''-7—''''':'''''''' ''''':,:':'7'''''''''''''''''''''':'''''''''' 5/8' GYPBOARD OVER 10'-2" A.F.F. METAL STUD FRAMING > B.O. CEILING (MEZZANINE) PAINTED DRYWALL OVER PT-2 3-5/8" MIL STUD. SEE :, :: :;.;: ', ± E1L1tG FINISH PLAN 1 /" PT-�2 PT�-2 . . . . , BRUSHED STAINLESS STEEL CLADDING WITH CONCEALED FLAT-LOCK SEAMS. STEEL BEAM, SEE STRUCTURAL GC TO USE CAULK JOINT AT FINISH Cii: Illi&/11 SURFACE. DRAWINGS >;. SALES A9�?!2 SS-1 SILICONE RUBBER SPACER METAL PAN STAIRS WITH TILE FINISH STAIR TREADS SHALL BE OF SELF ,,....._.__4 ...__..........., !..7.... CST-1 LEVELING CONCRETE WITH SETTING BED 4- ON TOP OF STEEL PLATE CONSTRUCTION " STAINLESS STEEL RAILING ::::::::::::::::::::::,,,_„„„„„„„ ._:„:„ --, ,„''' .„ US220 �`_ 14-0 •/„/,�i1�,'/,'� FINISH FLOOR (MEZZANINE) - P h : s1EL BEAM, SS.D WASHINGTON SQUARE LC-1 1 ;: R Q 9585 S.W. WASHINGTON SQUARE °o°o o°o 0°0 000°0°0°0 0°0 0°0°0'0 0 0"0 ov 0 to o,:o„o„o„o„o„o„o„ „o,.,o„o„o„o„o„o,,o„o,.,o„o„o„o : ----------- SUITE H08 1 10'-2” A.F.F. _ 9 PORTLAND, OR 97223..A.Lk B.O. CEILING (LEVEL 1) CLASS: RED 1 J :L. r uj ;r: : . J 1-HOUR ENCLOSURE +101 R • coo R 12X STRINGER. SEE � �� STORAGE � o '”` '- ° STRUCTURAL DRAWINGS ”` s a r ' g DOOR To i r, W SALES re 5/8” GYPBOARD OVER (-1-5 METAL STUD STUD FRAMING PT-2 0'-0” A.F.F. �"'' I FINISH FLOOR (LEVEL 1) l 3'=?-0” 1' CHANNEL STRINGER DETAIL I_ 12 SOFFIT AT BEAM 9 SECTION AT STAIRS (BOH) _ 3 ItiadTt 111,1 '.4. '' ' , , STAINLESS STEEL CLADDING (5) 1/4” THK. SANDED ONES PERK OVER STEEL CHANNEL STRINGER TREAD FOR SUP RESISTANCE AND A1-�►MEDA. :Al. • SS-1 ADA COMPLIANCE STONE TILE OVER THINSET ��yjT OVER 1/2 CEMENT BOAR i OVER CONCRETE FILLED METAL PAN STAIRS 8 CST-1 /' - 8" 1 Q'-1' 4'-0' I I 11 TREADS AT 11" LANDING /- 0 ‘,/. ............................................ 0 0 0 0 0 0°0 0 0 0 0o a°a o 0 0 o a o"0°0"0;0;0;00°0;0;0;0"0"0"0;0 .L.3._1L.L•.3:i C1 (T\ SALES ' o` imw I oA HANDRAIL, TYP •o 0. o` 0 f--i_ . I'? -.2-r„ . - . .z.-...:. Lr-----.(t— _ o' � c 1 1 1 I 1 I I 1 1 1 I I 1 I l 1 I 1„ ' .!::::: ::i;::: .:: :::',..: ,;',..;, !:;!..,.:., ..,:.,,,,z: I ::::., „ :::: „..:-..,, ::.•.:: ::::. 7./... o • o• STAB OPENING a.:; 11 ; 0 �o � AX. SHOWN DASHED Dennis Heath, Architect DASHED : a BEAM SHOWN DAS o, r�- .. .. . .. .. :_ .. 24]OII Mariner �o ” a ner Square Lapp 5 8 GYP. B . R D OVER •o'o•o'o'o•o'o•o'o'o'o'o•o•o'o•o'o•o' o'o•o•o'o• AI ameda CA 94501 STAIRWAY MTL STUD FRAMING . ' DOWN: 0 ON L3X3X 1 4 EMBED i 0 BEAM R !1 .. In S :-!..1 :::::: ) ii: Iii ili: ,:i.::- if, 1:1 .1 1.1.1 I W 1 0 X 4 ANCHOR i 2 U CONCRETE FILLED 1 STUDS 0 APPROX. 3 FROM ,.„. ..:.:.:, re"*N‘ MIL. . ,,, ... ,,..:r.,...ir.../.i.,. ��4MS - PAN ST N AND 18 O.C. AIRS WITH "- ENDS AN STONE Tl STO LE FINISH a rawin 9 s and written material appearing herein constit u te original iaal(COORDINATE W/ ST AI R MFG) ad an abli h d volt a s e rk aI the Architect and ma nit be duplicated, a du is ed CST-1 >, P 1 P used or disclosed without thout written consent of the Architect ``< -STEEL BEAM S.S.D. G :< :llI ::1 >L 1 1 c®DH ARCHITECTS- 2010 w. CONC. FILLED STL o0:o:o:o: as P A N STEEL PLATE ` ;�`: ■ 1 R STAINLESS STEEL HANDRAIL, TYP BOTH SIDES Q A Q C TREAD & RISERS r� 12 _ SS-1 -- t`----. 12" STEEL CHANNEL STRINGER '---'0 STRINGER, TYP N o . Date I s s u e i::i — — E * 05/28/10 100% SET 05/28/10 VT PACKAGE 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET $•sral'—Q' 1/2"4-0' 08/13/10 PERMIT/BID SET STAIR LANDING (MEZZANINE) _ ii ENLARGED PLAN AT STAIR (SALES) — MEZZANINE 2 USE BULL-NOSED TILE AT STAIR TREADS AA fa 0 A STAINLESS STEEL CO CLADDING OVER STEEL CHANNEL STRINGER - - S 7 S-1 SALES 4'-10" 2'-0 1/8" co-7/ y o I CONC. FILLED STL PAN STEEL I I I C _..... PLATE TREAD & RISERS STONE TILE OVER THINSET OVER 1/2' 10'-1" 4'-0" 10'-1' 'u°°°°°°°V°U °�°U L' E x . CEMENT BOARD OVER CONCRETE FILLED a� METAL PAN STAIRS 11 TREADS ® 11" LANDING 8 11 TREADS AT 11" „... c:-.., )„,, - ' ,- .. .-7 P CST-1 n'i 11' 1" MAX. - - - - - - - i- - 7 - -I- - T — ..r, I I 1 I 1 1 1 I 9 t: (5) 1/4 THK. SANDED UNES PER TREAD FOR CONCRETE FILLED METAL: 10• SUP RESISTANCE AND ( I I r PAN STAIRS WITH STONE �� TILE FINISH STAIRWAY ADA COMPLIANCE 41ALL BELOW SHOWN DA HED . CST-1 Project N o. 44122::::::• .. :,o STAINLESS STEEL HANDRAIL S c a l e AS NOTED / 5 8" GYPBOARD OVER METAL � ' SS-1 / STUD FRAMING, TYP :;:::•••:: :::::: :::::::::' •ii..-:'.-: ':1 :::;:: ::::::": :::::::::: :::::.:: --:-,:', ••'::::* :11' PT-2 Drawn By: DM/AN E ::::::::......-:.:k:. - 1 R:\HM\Projecta\2010_Projects\44122 Washington Sq\Drawings\CD\US22OJ192a.d (N) COLUMN 12 (N) COLUMN E ^ ' o o'o 0 0 0 0 0 0b0 0 0 0"0 0 0 0"0 0 _ _ _ ----- !Z `_#0 STRINGER, TYP E ip II �' _ i Drawing No. L 3" X 3" X 1/4" X 3" LAG FASTENED (__l J _ _ N TO FLOOR W/ EXPANSION ANCHOR _ STAIR DETAILS (ORDINATE W/ STAIR MFG) y (E) COLUMN, TYP (E) DEMISING WALL {SALES Q T _. STAIR 1/20=T-on STAIR LANDING (LEVEL 1) EN LAR GED PLAN AT (S AL ES) — LEVEL 1 .,.., _ A9.2 a ., + ' 5/8" GYP. BD. OVER fa 7/8 HAT CHANNEL `..- VYNIL BASE I T-6" MIN us. (2ND FL00 < 1 HOUR MIN RATED CONCRETE OVER METAL GYPBOARD SHAFT WALL, UL ( R) DECK AT STAIR LANDING • #0469, TYP. A i—VCT FLOORING HANGER COVER > B.O. CEILING r' ' ' HEADER , VCT-1 GYP. CEIUNG -2 > ;r DOOR TO CORRIDOR PT-2 - _ OF A.F.F.mik, CAB LINE, SHOWN —LIU T.O. OPENING STAINLESS STEEL HOUSE / r. DASHED > ~ _ HANDRAIL / ,- - „- ,..- - .:, / A ---.:: i ..zr. 1 < STAINLESS STEEL BRACES SS-1 i . , , HEAD / JAMB B US�2O SS-1 ` FINISH FLOOR (2ND FLOOR)} �, •. WASHINGTON SQUARE , .„ , : „, ,' HOISTWAY r 10 <. DOOR FROM SALES BEHIND 9585 S.W. WASHINGTON SQUARE ce _•. SUITE H08 O-0 " o.—o. PORTLAND, OR 97223 SILL PLATE r�, `� r7 ,: ,;, , FINISH FLOOR FINISH FLOOR (MEZZANINE) E) CLASS. RED -"� _ , 5" X 5" ANGLE � �,', SILL SUPPORT •01 ,1 a FASCIA ( OE T GUARD) 10'-2" A.F.F. i '. �r � r W B.O. CEIUNG < L 4 X 4 X 1/4" CEIUNG PLENUM FITTING ELEVATOR < (E) CMU WALL 0 ROOMS MACHINE ROOM VOID FACE �' ' - 4' ' ' - Ak, 1 i 3"=t-0� 1 1/2"=f-01' 1/4"=�--t1�' ilt:�,44,4‘ DETAIL AT STAIR SLAB EDGE — SALES _ 12 ELEVATOR SILL DETAIL 9 SECTION AT STAIRS (BACK OF HOUSE) 3 ! k k �� J' C- - b.....] CONCRETE OVER METAL • A .AMEDA, DECK AT STAIR LANDING ,,; ,, VCT FLOORING 12" STEEL CHANNEL GYP. BD. OVER MTL. STUD f�F AT LANDING STRINGER +"----7— FRAMING VCT-1 1 1/2" 3 1 1/2"0 0.0. STAINLESS ,� • STEEL HANDRAIL `' SS-1 Li i \ i, f---- 11011 LI-1 METAL BRACKETS: 4'-O" O.C. MAX. W/ (3) 1/4"0 SELF - DR C' TAPPING SCREWS THRU 3/16 Dennis Heath, Architect z 0 .---- THICK BACK PLATE FOR GRAB 2410 Mariner Square loop BAR SUPPORT - TYP. Alameda, CA 94501 , 0 ''' ,-: ' ' ' ' , -71 0 , .„ . , w CO 0 i4W4r < MALL CORRIDOR STAIRWAY OMMNMMIMMMMMNMIIIIIIIIIIIMIMINIIIIIIIIIIIIIIIIIIIIIIIIIININIIIIIIIIMIII ROOF DRAIN PIPE Drawings and written material appearing herein constitute original ::2 .4,........_i__ _ ° I and unpublished cork of the Architect and may not be duplicated, I 7--) used or disclosed without written consent of the Architect N/ ®DH ARCHITECTS 2010 NOTES: 12" x 3/16" THK PLATE i 5'_0" i 1 . PROVIDE SMOOTH HANDRAILS W/ #10 SCREWS 3" O.C. QAQC CONC. FILLED METAL PAN W/NO SHARP CORNERS EA. STUD: PLATE CONT. N o . D a t e I s s u e TREADS WITH METAL RISERS ENTRE LENGTH OF SPAN. 2. ALL ENDS SHALL RETURN (i-"c 05/28/10 100% SET TO WALL — 05/28/10 VT PACKAGE 0 07/02/10 100% COMPLETE SET r 07/28/10 LANDLORD SET 3m4-°. I 7=T-0.T'-0' \ 08/13/10 PERMIT/BID SET STAIR LANDING (LEVEL 2 — REAR) _ ii HANDRAIL DETAIL _ 8 I STAINLESS STEEL HANDRAIL, TYP BOTH SIDES STEEL STRINGER : kV SS-1 In 12 STEEL CHANNEL STRINGER ^ m �' • CONCRETE FILLED mil. PAN STAIRS K r. F ,, f J 71i r /%rr .10--, r CONC. FILLED STL PAN STEEL %% r fr '�. r :0:-:.::.:11-:-::-..:-.:::::1-1� >r ,.. ....... .: .,.......'. . i .. ,..:.. �0-... ....: ...Al . ....... ..:... .....,3.. .....A PLATE TREAD & RISERS j\ .........i B. 1 1/2. = 1-0" TREAD O I e PTICAL WARNING STRIP 1 . r 2" \ _ . J 2 WIDE X 1/4" -THICK NON-SLIP ___ SET FLUSH IN TREAD TO COMPLY s 1 WITH A.D.A.A.G. Project No. 44122 J '---/TREAD-''TREAD 1-HOUR RATED WALL (uL U Ass) V TYPICAL BOTTOM TREAD OR TOP ... -. :1 LANDING S c a l e AS NOTED —VCT FLOORING V AT LANDING DrornBy: DM/AN VCT-1 1/4" ROUNDED NOSE Ls 5/1 6" MAX. El CD R:\HM\Projects\2010_Projects\44122 Washington Sq\Qrowings\CD\US220..A92b.d F2 L 3"X3"X1/4" X 3" LG FASTEN TO Drawing No. - RI — FLOOR W/ EXPANSION ANCHOR STAIR DETAILS N (COORDINATE W/ STAIR MFG) A 3' :t—Os (BACK OF HOUSE) 0 I ... STAIR LANDING (LEVEL 1 — REAR) " " 10 STAIR TREAD 3�-rte STAIR (BACK OF HOUSE) — 1/2 t-O 1 o _ _ 7 ENLARGED PLAN AT LEVEL 2 _ A9 . 2 CONTRACTING REQUIREMENTS LaMiCiiiirinela SECTION 01500 - TEMPORARY FACILITIES AND CONTROLS SECTION 01735- SELECTIVE DEMOLITION FOR REMODELING lialli A. TEMPORARY SERVICES: PROVIDE TEMPORARY ELECTRICITY, LIGHTING, HEAT AND VENTILATION, WATER, SANITARY A. GENERAL REMOVE FROM SITE EXISTING MATERIALS, CONSTRUCTION AND UTILITIES AS NEEDED TO COMPLETE SECTION 00700 GENERAL CONDITIONS FACILITIES ENCLOSURES AND BARRIERS AS REQUIRED BY AUTHORITIES AND AS REQUIRED TO COMPLETE PROJECT PROJECT. 00800 SUPPLEMENTARY CONDITIONS - � 1. REMOVE EXISTING ELEMENTS INDICATED AND ENCOUNTERED DURING CONSTRUCTION, AS NEEDED TO COMPLETE A. GENERAL CONDITIONS: THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, AIA DOCUMENT A201, 1997 1. COORDINATE AVAILABIUTY OF EXISTING SERVICES WITH OWNER; DO NOT USE SERVICES WITHOUT PRIOR OWNER WORK. DIVISION 1 MERAL RMEMEw s EDITION, IS A PART OF THIS CONTRACT, AND SHALL GOVERN WORK. WRITTEN APPROVAL. 2. REMOVE ONLY THOSE ELEMENTS NECESSARY FOR COMPLETION OF PROJECT, REPLACE OR REPAIR ELEMENTS 1. A COPY WILL BE MADE AVAILABLE BY ARCHITECT UPON REQUEST. B. CONSTRUCTION AIDS: MAINTAIN NOISE, DUST AND POLLUTION CONTROL, SECURITY, AND FIRE PROTECTION. UNNECESSARILY REMOVED OR DAMAGED DURING CONSTRUCTION. SECTION 01110 SUMMARY OF WORK C. ENCLOSURES: PROVIDE TEMPORARY WEATHER-TIGHT CLOSURES FOR EXTERIOR OPENINGS TO MAINTAIN ACCEPTABLE 3. CAREFULLY REMOVE AND STORE ITEMS INDICATED FOR REUSE IN PROJECT AND COORDINATE WITH OTHER TRADES 01300 ADMINISTRATIVE REQUIREMENTS WORKING CONDITIONS, FOR PROTECTION OF MATERIALS, TEMPORARY HEATING, AND TO PREVENT UNAUTHORIZED FOR MODIFICATIONS AND REINSTALLATION. 01310 PROJECT MANAGEMENT AND COORDINATION END OF SECTION ENTRY. 4. COORDINATE REMOVAL AND STORAGE OF MATERIALS AS INDICATED AND AS DIRECTED FOR OWNER'S MAINTENANCE 01400 QUALITY REQUIREMENTS D. BARRIERS: PROVIDE AS REQUIRED TO PREVENT UNAUTHORIZED ENTRY, TO PROTECT ADJACENT PROPERTIES, AND AS STOCK; DELIVER TO LOCATION ON SITE AS DIRECTED BY OWNER. 01500 TEMPORARY FACILITIES AND CONTROLS DOCUMENT 00800 - SUPPLEMENTARY CONDITIONS REQUIRED BY GOVERNING AUTHORITIES. B. PROTECTION: PREVENT MOVEMENT AND SETTLEMENT OF ADJACENT STRUCTURE; PROVIDE BRACING, SHORING, AND 01600 PRODUCT REQUIREMENTS UNDERPINNING AS NEEDED AND BE RESPONSIBLE FOR SAFETY AND SUPPORT OF STRUCTURES. 01630 PRODUCT SUBSTITUTION PROCEDURES A. CONDITIONS AND REQUIREMENTS: GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS AND DIVISION 1 - GENERAL E. CLEANING DURING CONSTRUCTION: PROVIDE PERIODIC CLEANING DURING PROGRESS OF WORK. 1. ASSUME LIABILITY FOR SUCH MOVEMENT AND SETTLEMENT. REQUIREMENTS CONTAIN INFORMATION NECESSARY FOR COMPLETION OF EVERY PART OF PROJECT. 01700 EXECUTION REQUIREMENTS F. PROJECT IDENTIFICATION: PROVIDE 32 SQUARE FOOT SIGN LISTING TITLE OF PROJECT, OWNER, ARCHITECT, C. UTILITIES: CONTACT APPLICABLE UTILITY COMPANIES PRIOR TO DISCONNECTING UTILITIES; DISCONTINUE WORK IF 01730 CUTTING AND PATCHING B. DIVISION 1: WHERE PROVISIONS OF GENERAL CONDITIONS RELATE TO PROJECT ADMINISTRATION OR WORK-RELATED PROFESSIONAL CONSULTANTS AND CONTRACTOR; EXTERIOR PLYWOOD CONSTRUCTION PAINTED BY PROFESSIONAL SIGN UNEXPECTED UTILITY LINES ARE ENCOUNTERED. 01735 SELECTIVE DEMOLITION FOR REMODELING REQUIREMENTS OF THE CONTRACT, THOSE PARAGRAPHS ARE EXPANDED IN DIVISION 1. PAINTER. 1. DETERMINE LINE SOURCE AND USE PRIOR TO REMOVAL 01770 CLOSEOUT PROCEDURES C. SUBCONTRACTORS: CONTRACTOR AGREES TO BIND SUBCONTRACTORS AND MATERIAL SUPPLIERS TO TERMS OF 1. OTHER SIGNS: SUBJECT TO OWNER AND ARCHITECT APPROVAL. 2. CAP AND IDENTIFY EXISTING UTILITY LINES REMOVED. US220 01780 WARRANTIES GENERAL AND SUPPLEMENTARY CONDITIONS, INCLUDING ARBITRATION. D. PROCEDURES: SELECTIVELY REMOVE EXISTING CONSTRUCTION IN AN ORDERLY, CAREFUL, AND SAFE MANNER, IN 01820 SYSTEMS DEMONSTRATION D. PAYMENTS: 90% OF AMOUNT DUE WILL BE PAID UNTIL PROJECT IS 50% COMPLETE; NO FURTHER AMOUNT WILL BE G FOR DCTELEPHO RETAINED IF WORK REMAINS SATISFACTORY AND SURETY COMPANY APPROES. 1. USE METHODS WHICH DO NOT DAMAGE MATERIALS INDICATED TO REMAIN. E. INSURANCE: AS APPROVED BY OWNER. 1. PROVIDE CELLULAR TELEPHONES FOR ON-SITE SUPERVISOR AND SUBMIT REGULARLY UPDATED SCHEDULE OF 2. TAKE PRECAUTIONS AS REQUIRED TO PREVENT UNNECESSARY DUST AND POLLUTION. S.W. WASHINGTON SQUARE ON-SITE SUPERVISORS WITH CELLULAR TELEPHONE NUMBERS. 3. REMOVE DEMOLISHED MATERIALS FROM SITE UNLESS OTHERWISE DIRECTED; DISPOSE OF IN ACCORDANCE WITH NOT USED. F. PERFORMANCE BOND AND LABOR AND MATERIAL PAYMENT BOND: 100% EACH. H. REMOVAL: REMOVE TEMPORARY CONSTRUCTION FACILITIES PRIOR TO SUBSTANTIAL COMPLETION. APPLICABLE CODES. SUITE H08 G. MISCELLANEOUS DEFINITIONS: 1. CLEAN AND REPAIR DAMAGE CAUSED BY CONSTRUCTION FACILITIES. PORTLAND, OR 97223 DMVASIQN 3 00E 1. APPROVED: REQUIRES WRI I I tN ACTION BY ARCHITECT AS DOES TERMS SUCH AS DIRECTED, SELECTED, REQUIRED, END OF SECTION ORDERED, I. SITE WASTE MANAGEMENT: COMPLY WITH APPLICABLE AUTHORITIES FOR SITE WASTE MANAGEMENT; MINIMUM 50% OF DESIGNATED, ACCEPTED, ACCEPTABLE, AND SATISFACTORY. TOTAL PROJECT WASTE TO BE DIVERTED FROM LANDFILL. EFFECT OPTIMUM CONTROL OF SOUD WASTES. PREVENT SECTION 017'70 - aAsEOur PROCEDURES CLASS: RED SECTION 03300 CAST-IN-PLACE CONCRETE 2. FURNISH: SUPPLY AND DEUVER TO PROJECT, UNLESS OTHERWISE STATED IN GREATER DETAIL. ENVIRONMENTAL POLLUTION AND DAMAGE. A. SUBSTANTIAL COMPLETION: PROVIDE DOCUMENTATION STATING WORK HAS BEEN SUBSTANTIALLY COMPLETED. WHERE 03540 CEMENTITIOUS UNDERLAYMENT 3. INSTALL OPERATIONS AT PROJECT, FROM INSPECTING AND UNLOADING, TO COMPLETION IN PLACE, READY FOR 1. WASTE: CONSTRUCTION WASTE INCLUDE SOLID WASTES SUCH AS BUILDING MATERIALS, PACKAGING, RUBBISH, OWNER REQUIRES USE OF SPACE PRIOR TO FINAL COMPLETION, PROVIDE LIST OF ITEMS TO BE COMPLETED. 03542 SELF-DRYING, SELF-LEVELING CEMENT TOPPING INTENDED USE. DEBRIS, AND RUBBLE RESULTING FROM CONSTRUCTION OPERATIONS. 1. ARCHITECT WILL REVIEW LIST OF ANY ITEMS TO BE COMPLETED AND SUPPLEMENT LIST WITH ITEMS CONSIDERED 4. PROVIDE: FURNISH AND INSTALL, COMPLETE AND READY FOR INTENDED USE, UNLESS OTHERWISE STATED IN 2. RECYCLING: IMPLEMENT RECYCLING PROGRAM THAT INCLUDES SEPARATE COLLECTION OF RECYCLABLE WASTE TO BE INCOMPLETE OR UNACCEPTABLE. GREATER DETAIL. MATERIALS BY BOTH CONTRACTOR AND SUBCONTRACTORS. B. FINAL COMPLETION: SUBMIT CERTIFICATION WORK IS IN COMPUANCE WITH CONTRACT DOCUMENTS, SYSTEMS HAVE DNISION 4 MASONRY BEEN TESTED AND ARE OPERATIONAL, AND WORK IS READY FOR FINAL INSPECTION. 3. REBATES, TAX CREDITS, AND OTHER SAVINGS OBTAINED FOR RECYCLED AND RE-USED MATERIALS SHALL ACCRUE C. RECORD DOCUMENTS: MAINTAIN COMPLETE AND UP-TO-DATE RECORD DOCUMENTS; KEEP SEPARATE FROM FIELD NOT USED. END OF SECTION TO CONTRACTOR. DOCUMENTS; OWNER WILL FURNISH SET FOR RECORD DRAWINGS. D. DATA: SUBMIT PROJECT RECORD DOCUMENTS, MATERIAL AND FINISH DATA, OPERATION AND INSTRUCTION MANUALS, END OF SECTION WARRANTIES AND BONDS AT COMPLETION; SUBMIT IN COMPUTERIZED COMPACT DISK (CD'S) WHERE AVAILABLE. DIVISION 5 METALS, 1. SUBMIT BOUND IN 8-1/2" BY 11" THREE RING BINDERS WITH DURABLE PLASTIC COVERS. ARRANGE IN FORMAT SECTION 01600 - PRODUCT RE EVENTS SIMILAR TO SPECIFICATIONS. ,� Atli 01110 - SUMMARY YMORIC N ; SECTION 05500 METAL FABRICATIONS B. PRODUCTS: MATERIALS AND EQUIPMENT SHALL BE NEW AND OF TYPE INTENDED FOR USAGE INDICATED. LIKE A. SCOPE: PROJECT CONSISTS OF CONTRUCTION OF H&M STORE AS INDICATED IN CONTRACT DOCUMENTS. END OF SECTION � i COMPONENTS SHALL BE BY ONE MANUFACTURER AND COMPONENT PARTS SHALL BE INTERCHANGEABLE. �'J ' �it' t 05722 STAINLESS STEEL AND GLASS RAILINGS » OA\ �'► ,,,1. ITEMS NOTED NIC (NOT IN CONTRACT) WILL BE FURNISHED AND INSTALLED BY OWNER OR UNDER SEPARATE 'k`y. res CONTRACT. C. SUBMITTALS: SUBMIT COMPLETE LIST OF PRODUCTS BEING PROPOSED FOR INSTALLATION TABULATED BY SECTION 01780 - DMSbN 6 WOW AND PILAS?1CS SPECIFICATION NUMBER AND TITLE. A. WARRANTIES: PROVIDE WARRANTIES AS INDICATED, SIGNED BY CONTRACTOR AND MANUFACTURER; FORM AS _ •--3 B. WORK SEQUENCE: COORDINATE CONSTRUCTION SCHEDULE, OPERATIONS AND USE OF PREMISES WITH ARCHITECT AND D. QUALITY ASSURANCE: COMPLY WITH INDUSTRY STANDARDS EXCEPT WHEN MORE STRINGENT TOLERANCES ARE APPROVED BY OWNER PRIOR TO EXECUTION. OWNER. REQUIRED. PERFORM WORK BY PERSONS QUALIFIED TO PRODUCE WORKMANSHIP OF SPECIFIED QUALITY. 1. WARRANTIES SHALL BE IN ADDITION TO AND NOT A LIMITATION OF OTHER RIGHTS OWNER MAY HAVE •AGAINST ' ALAMEDA.CA SECTION 06105 MISCELLANEOUS ROUGH CARPENTRY C. CONTRACTOR USE OF PREMISES: LIMIT TO AREAS INDICATED ON DRAWINGS AND AS SPECIFIED; LIMIT ACCESS AS 1. ANCHORS: SECURE PRODUCTS IN PLACE WITH POSITIVE ANCHORAGE DEVICES DESIGNED AND SIZED TO WITHSTAND CONTRACTOR UNDER CONTRACT DOCUMENTS AND AS PRESCRIBED BY LAW, REGARDLESS OF WORDING OF `)) C§S 06200 FINISH CARPENTRY DIRECTED BY OWNER. STRESSES, VIBRATION AND RACKING, INCLUDING SEISMIC LOADS. WARRANTY. 06400 ARCHITECTURAL WOODWORK D. BUILDING OCCUPANCY: OTHER AREAS MAY BE OCCUPIED DURING CONSTRUCTION; COOPERATE WITH OWNER TO E. DELIVERY, STORAGE AND HANDLING: TRANSPORT, HANDLE, STORE, PROTECT AND INSTALL MANUFACTURED ITEMS IN B. LIMITATIONS: WARRANTIES NEED NOT COVER FAILURES FROM UNUSUAL OR ABNORMAL PHENOMENA OF THE 14 OF CA.v. MINIMIZE CONFLICT AND TO FACILITATE BUILDING OPERATIONS. STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. ELEMENTS, OWNER'S MISUSE, MALTREATMENT OR IMPROPER MAINTENANCE WORK, VANDALISM AFTER SUBSTANTIAL E. UNES AND LEVELS: PROVIDE FIELD MEASUREMENTS; ESTABLISH LINES AND LEVELS BY USE OF RECOGNIZED COMPLETION, OR WAR. NA DMSION 7 THERMAL A MOISTURE PROTECTION 'S INSTRUCTIONS, CONSULT F. REGULATORY REQUIREMENTS: PROJECT HAS BEEN DESIGNED IN ACCORDANCE WITH APPLICABLE CODES. COMPLY WITH WITH ARCHITECT. END OF SECTION SECTION 07260 SLAB-ON-GRADE VAPOR RETARDER CODE REQUIREMENTS FOR CONSTRUCTION. INFORM ARCHITECT OF DISCREPANCIES OBSERVED OR NOTED BY OTHERS. 2. STORE AND PROTECT PRODUCTS AND FINISHES FROM DAMAGE FROM CONSTRUCTION OPERATIONS; COMPLY WITH 01820 - SYSTEMS DEMONSTRATIONS 07590 ROOF REPAIRS G. STANDARDS: COMPLY WITH STANDARDS REFERENCED EXCEPT WHERE MORE RIGID REQUIREMENTS ARE REQUIRED BY MANUFACTURER RECOMMENDATIONS. A. SUMMARY: PROJECT INCLUDES SPECIAL FACILITY START-UP PROCESS TO BRING FACILITY TO FULLY OPERATIONAL loomoomorl 07810 SPRAYED ON FIREPROOFING CODE. DATE OF STANDARD IS THAT IN EFFECT AS OF DATE DOCUMENTS ARE ISSUED, EXCEPT WHEN SPECIFIC DATE END OF SECTION STATE, FREE OF DEFICIENCIES, IN MOST EFFICIENT AND TIMELY MANNER ACHIEVABLE. 07840 FIRESTOPPING IS SPECIFIED. H. OWNER FURNISHED CONTRACTOR INSTALLED ITEMS: OWNER WILL ARRANGE FOR AND PAY FOR PRODUCT AS END OF SECTION 07900 JOINT SEALERS INDICATED ON DRAWINGS TO BE DELIVERED TO PROJECT SITE FOR CONTRACTOR INSTALLATION. 01630 - PROJECT SUS ORES 1. CONTRACTOR SHALL INSPECT, RECEIVE, UNLOAD, STORE, INSTALL AND FINISH. A. SUMMARY: PROVIDE PRODUCTS INDICATED OR APPROVED; REQUESTS FOR SUBSTITUTIONS OF OTHER PRODUCTS WILL dVln 2 SfIE OLMJCt1CK L fl 8 DOORS AND WINDOWS, BE CONSIDERED IF SUBMITTED IN WRITING. B. CONTRACTOR OPTIONS: PROVIDE PRODUCTS AND MANUFACTURERS NAMED IN SPECIFICATIONS, SUBMIT REQUEST FOR 2111111.121112111E END OF SECTION SUBSTITUTION FOR PRODUCTS AND MANUFACTURERS NOT SPECIFICALLY NAMED WHERE NAMES ARE LISTED. SECTION 08110 STEEL DOORS AND FRAMES SECTION 03300 - CAST-IN-PLACE COMMIE 08210 WOOD DOORS SECTION 01300 - ADMINISTRATIVE C. SUBSTITUTIONS: CONTRACTOR SHALL INVESTIGATE PROPOSED SUBSTITUTIONS AND DETERMINE IF EQUIVALENT TO A. GENERAL: PROVIDE FORMWORK, REINFORCING, AND CAST-IN-PLACE CONCRETE AS REQUIRED TO COMPLETE PROJECT PRODUCTS SPECIFIED. AS INDICATED, TO COMPLY WITH STRUCTURAL DRAWINGS, REQUIREMENTS OF ACI AND APPUCABLE CODES. 08310 ACCESS DOORS AND PANELS A. PROCEDURES: CONTRACTOR SHALL REVIEW AND APPROVE SUBMITTALS PRIOR TO SUBMITTING TO ARCHITECT. INFORM Dennis Heath, Architect 1. SUBMITTALS SHALL INCLUDE COST OR TIME BENEFITS FOR SUBSTITUTIONS; FAILURE TO INDICATE COST OR TIME 1. SLAB-ON-GRADE VAPOR RETARDER IS IN SECTION 07260. 08335 OVERHEAD COILING GRILLES ARCHITECT IN WRITING A T SUBMISSION OF PROPOSED DEVIATIONS FROM CONTRACT DOCUMENTS. BENEFIT IS JUSTIFICATION FOR REJECTION. B. STANDARDS: COMPLY WITH APPLICABLE BUILDING CODE, AMERICAN CONCRETE INSTITUTE (ACI) AND CONCRETE 2 4 7 0 M a r i n e r Square loop 08410 ALUMINUM FRAMED STOREFRONTS 1. SUBMITTAL REPRESENTS FIELD MEASUREMENTS, FIELD CONSTRUCTION CRITERIA, MATERIALS, CATALOG NUMBERS D. CONTRACTOR'S REPRESENTATION: REQUESTS CONSTITUTE THAT CONTRACTOR HAS INVESTIGATED PROPOSED PRODUCTS REINFORCING STEEL INSTITUTE (CRSI) STANDARDS AS APPLICABLE. Alameda, AND SIMILAR DATA HAVE BEEN DETERMINED AND VERIFIED BY CONTRACTOR. C A 94501 08450 ALL-GLASS ENTRANCES AND STOREFRONTS AND DETERMINES IT MEETS OR EXCEEDS SPECIFIED PRODUCTS AND WAIVES CLAIMS FOR ADDITIONAL COSTS THAT C. FORMWORK: ACI 347; PROVIDE NON-BONDING AND NON-STAINING FORM SEALERS. 2. REVIEW OF SUBMITTALS BY ARCHITECT SHALL BE FOR DESIGN CONCEPT ONLY AND SHALL NOT BE CONSTRUED SUBSEQUENTLY BECOME APPARENT. D. REINFORCING: COMPLY WITH ACI 315 AND 318, CRSI 59 AND 63, AND AWI D12.1; ASTM A615, DEFORMED 0846E AUTOMATIC ENTRANCE DOORS 2. APPROVING DEPARTURES FROM CONTRACT DOCUMENTS. REINFORCING BARS, GRADE 60 UNLESS OTHERWISE INDICATED, AND ASTM A185 WELDED WIRE FABRIC; GALVANIZED. 08480 BALANCED ENTRANCE DOORS B. CONSTRUCTION PROGRESS SCHEDULE: SUBMIT BOTH BAR CHARTS AND CONTRACTOR'S STANDARD COMPUTERIZED E. SUBSTITUTION DBAS D ON INSUFFICIENT INFORMATION; USE SE ONLY SUBSTITUTIONS APPRO ED IN WRITING.T PROPOSED E. CONCRETE: COMPLY WITH ACI 301 AND 318; NOT LESS THAN 3000 PSI AT 28 DAYS, MAXIMUM 1" AGGREGATE, 08700 HARDWARE SCHEDULES, UPDATED REGULARLY, NO LESS THAN MONTHLY. MAXIMUM 3" SLUMP, 4% TO 5% AIR ENTRAINMENT. UNLESS OTHERWISE INDICATED. 08725 LOW ENERGY DOOR OPERATORS C. SCHEDULE OF VALUES: AIA FORM G703 OR APPROVED FORMAT. END OF SECTION 1. PORTLAND CEMENT: ASTM C150, TYPE I OR I I STANDARD. D r a w i n g s a n d I r i t t e n m a t e r i a l a p p e a r i n g h e r e i n c o n s t i t u t e o r i g i n a l 08800 GLAZING 2. AGGREGATES: ASTM C33, NORMAL WEIGHT. and unpublished cork of the Architect and maT not be duplicated, D. SHOP DRAWINGS: SUBMIT ONE REPRODUCIBLE AND THREE PRINTS; PROVIDE FOR CUSTOM PRODUCTS AND PRODUCTS 3. ADMIXTURES: ASTM C494 AS NEEDED; NO CHLORIDES PERMITTED. used o r disclosed without r r i t t e a consent a f the A r c h i t e c t NOT FULLY IDENTIFIED BY PRODUCT DATA. SECTION 01700 - EXECUTION REQUIREMENTS F. FINISHES: COMPLY WITH ACI FOR STANDARD CONCRETE FINISHES. DIViON 9 FINISHES E. PRODUCT DATA SUBMIT NUMBER REQUIRED BY CONTRACTOR PLUS TWO FOR ARCHITECT; INDICATE ITEM TO BE USED A. INSTALLER QUALIFICATIONS: INSTALLERS TO HAVE MINIMUM FIVE YEARS SUCCESSFUL EXPERIENCE INSTALLING ITEMS 1. FLOOR SLABS: PROVIDE HARDENER/SEALER AT FLOORS INDICATED TO BE EXPOSED AND AS REQUIRED FOR THIN O D H ARCHITECTS-2 010 WHERE DATA FOR MORE THAN ONE PRODUCT OR OPTION IS INCLUDED; PROVIDE FOR EACH STOCK MANUFACTURED SIMILAR TO THOSE REQUIRED FOR PROJECT, EXCEPT FOR INDIVIDUALS IN TRAINING UNDER DIRECT SUPERVISION OF FLOOR FINISHES. SECTION 09260 GYPSUM BOARD ASSEMBLIES ITEM. EXPERIENCED INSTALLER. G. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, REFERENCED STANDARDS, AND APPUCABLE CODE Q A Q C 09300 TILE F. SAMPLES: SUBMIT SAMPLES FOR EACH TYPE OF EXPOSED FINISH, COLOR, AND TEXTURE; MINIMUM SIZE 6", MAXIMUM B. EXAMINATION: BEGINNING INSTALLATION OF A PRODUCT SIGNIFIES INSTALLER HAS EXAMINED SUBSTRATES, AREAS, AND REQUIREMENTS. No . Dote Issue 09510 ACOUSTICAL CEILINGS SIZE 12" UNLESS OTHERWISE SPECIFIED; SUBMIT ONE SAMPLE FOR ARCHITECT TO RETAIN, ONE SAMPLE FOR FIELD CONDITIONS FOR COMPUANCE WITH MANUFACTURER REQUIREMENTS FOR TOLERANCES AND OTHER CONDITIONS END OF SECTION OFFICE, AND NUMBER REQUIRED BY CONTRACTOR. AFFECTING PERFORMANCE. 05/28/10 100% SET 09650 RESILIENT TILE FLOORING G. MANUFACTURER'S CERTIFICATES: PROVIDE THREE. C. MANUFACTURER'S INSTRUCTIONS: WHEN WORK IS SPECIFIED TO COMPLY WITH MANUFACTURERS' RECOMMENDATIONS SECTION 03540 - CEMENTMOUS IMDERLAYMENT 05/28/10 VT PACKAGE 09657 RESILIENT BASE OR INSTRUCTIONS, DISTRIBUTE COPIES TO PERSONS INVOLVED, AND MAINTAIN ONE SET IN FIELD OFFICE. A. GENERAL PROVIDE POURED CEMENTITIOUS UNDERLAYMENT SYSTEM, NOT INTENDED AS FINISHED TRAFFIC SURFACE, 09680 CARPET END OF SECTION D. INSTALLATION: COMPLY WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS UNLESS INCLUDING ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. 07/02/10 1 00% COMPLETE SET 09900 PAINTS AND COATINGS MORE RESTRICTIVE REQUIREMENTS ARE SPECIFIED. B. INSTALLER: FIRM WITH MINIMUM FIVE YEARS SUCCESSFUL EXPERIENCE, REGULARLY ENGAGED IN INSTALLATION OF 07/28/10 LANDLORD SET E. FINAL CLEANING: CLEAN INTERIOR AND EXTERIOR SURFACES EXPOSED TO VIEW REMOVE TEMPORARY LABELS STAINS, SPECIFIED MATERIALS, PROPERLY EQUIPPED AND ACCEPTABLE TO MANUFACTURER. SECTION 01310 - PROJECT CEMENT AND cOORDI A ION C. TROWEL APPLIED SYSTEM: ARDEX, INC./FEATHER FINISH, CAPABLE OF RECEIVING FEATHER EDGE TO EXISTING FLOOR; 08/13/10 PERMIT/BID SET D 10 SPECIALI S, A. COORDINATION: COORDINATE WORK OF VARIOUS TRADES; VERIFY CHARACTERISTICS OF INTERRELATED OPERATING AND FOREIGN SUBSTANCES; POLISH TRANSPARENT AND GLOSSY SURFACES; VACUUM CARPETED AND SOFT SURFACES; 4000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. CLEAN DUCTS; CLEAN SITE. EQUIPMENT ARE COMPATIBLE. F. PROTECTION: COVER PRODUCTS SUBJECT TO DETERIORATION WITH IMPERVIOUS SHEET COVERING, PROVIDE D. SELF-LEVELING SYSTEM: ARDEX, INC./K-15 POURABLE CEMENTITIOUS, HIGH-STRENGTH, FAST-SETTING, NON-SHRINK, SECTION 10440 SIGNAGE 1. COORDINATE WORK HAVING INTERDEPENDENT RESPONSIBILITIES FOR INSTALLING, CONNECTION TO, AND PLACING IN VENTILATION TO AVOID CONDENSATION AND TRAPPING WATER. SELF-LEVELING UNDERLAYMENT; 4000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. 10500 LOCKERS SERVICE. E. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTION FOR EACH TYPE OF B. SUBMITTALS: PREPARE COORDINATION DRAWINGS FOR AREAS WHERE SPACE AVAILABILITY IS LIMITED AND UNDERLAYMENT, TROWEL APPLIED FOR FEATHER EDGE AND SELF-LEVELING. 10810 TOILET ACCESSORIES END OF SECTION NECESSITATES MAXIMUM UTILIZATION OF SPACE, AND WHERE SEPARATE ENTITIES, PRODUCTS, AND MATERIALS REQUIRE COORDINATION. END OF SECTION DIVISION 11 EQUIPMENT, C. SUPERVISORY PERSONNEL: PROVIDE SUPERVISORY PERSONNEL IN ADDITION TO PROJECT SUPERINTENDENT; SUBMIT SECTION 01730 CUTTING MD PATCH 03542 - SELF-DRYINlG, SELF-t1111E1.IN4 CEMENT TOPPING UST OF STAFF NAMES AND POST COPIES IN PROJECT MEETING ROOM. A. CUTTING AND PATCHING: CUT AND FIT COMPONENTS AS REQUIRED; PATCH DISTURBED AREAS TO MATCH ADJACENT A. , ERAL: CUSTOM-TINTED SELF-LEVELING, FAST DRYING, POURABLE OR PUMPABLE CEMENT-BASED CONCRP SECTION 11452 APPLIANCES D. PROJECT MEETINGS: SCHEDULE AND ADMINISTER MEETINGS, MAKE PHYSICAL ARRANGEMENT, PREPARE AGENDA, MATERIALS AND FINISHES. TOP• DESIGNED FOR RESURFACING AND LEVELING INTERIOR SUBSTRATES. PRESIDE AT MEETINGS AND RECORD MINUTES. 1. MAKE PARTS FIT TOGETHER PROPERLY. B. QUALITY SURANCE: DIVLSION 12 FLIINIGS 2. UNCOVER WORK TO PROVIDE FOR INSTALLATION OF ILL-TIMED WORK. A. INST' • ION SHALL BE BY AN EXPERIENCE APPLICATOR APPROVED BY THE MANUFACTURER. END OF SECTION 3. REMOVE AND REPLACE DEFECTIVE WORK. B. MANUFAC - R'S CERTIFICATIONS: I. PRODU ONTAINS A MINIMUM OF 10% CALCIUM ALUMINATE CEMENT. NOT USED. 4. REMOVE AND REPLACE WORK NOT CONFORMING TO CONTRACT DOCUMENTS. II. PRODUCT ' TAINS A MINIMUM OF 15% IRON ORE SLAG BY WEIGHT. SECTION 01400 - QUALITY REQUIRDENTS 5. REMOVE SAMPLES OF INSTALLED WORK AS REQUIRED FOR TESTING. III. FLOORING CO r'CTOR SHALL SUBMIT FOR APPROVAL PRIOR TO SITE INSTAL • • A 12" X 12" SAMPLE A. GENERAL: MAINTAIN QUALITY CONTROL OVER SUPPLIERS, MANUFACTURERS, PRODUCTS, SERVICES, SITE CONDITIONS 6. PROVIDE ROUTINE PENETRATIONS OF NON-STRUCTURAL SURFACES. PREPARED USING �UIPMENT, SUPPLIES AND METHODS OF FIELD INSTALLA • DIVISION 13 SPECIAL C. MANUFACTURER AND PRODUCTS: AND WORKMANSHIP. B. REFINISHING: REFINISH ENTIRE SURFACES AS NECESSARY TO PROVIDE EVEN FINISH TO MATCH ADJACENT FINISHES; A. DRYTEK FLOORING SOLUTION; •IRTSMOUTH, NH; TEL: 603.334.3440. B. MANUFACTURER'S FIELD SERVICES: PROVIDE MANUFACTURER OR SUPPLIER QUALIFIED PERSONNEL FOR ON-SITE FOR CONTINUOUS SURFACES REFINISH TO NEAREST INTERSECTION, FOR AN ASSEMBLY REFINISH ENTIRE UNIT. B. PRODUCTS: REFER TO MEP DRAWINGS OBSERVATIONS AS REQUIRED. I. DRYTEX 9400W-SPCL C. MOCK-UPS: CONSTRUCT FIELD SAMPLES AND MOCK-UPS ON SITE AS REQUIRED. END OF SECTION II. PRIMER: DRYTEK . MASON 14 CONVEYING SYSTE S D. TESTING LABORATORY SERVICES: WHERE REQUIRED BY APPLICABLE AUTHORITIES PROJECT TESTING SHALL BE BY AN III. WATER: CLEAN, POTABLE AND COOL IT WAR THAN 70 DEGREE F]. D. PREPARATION: APPROVED TESTING LABORATORY, AS REQUIRED BY SPECIFICATIONS AND BY APPLICABLE CODES. A. PREPARE SUBSTRATE IN ACCORDANCE OF MAN '' 'ER'S WRITTEN INSTRUCTIONS. SECTION 14130 ESCALATORS 1. TESTING REQUIRED FOR PROJECT WILL BE PAID FOR BY OWNER EXCEPT RETESTING WILL BE PAID FOR BY B. SUBSTRATE SHALL BE SOUND AND SOLID, " E FROM : T, DIRT, OIL, GREASE, PAINT OR ANY Project N o. 44122 CONTRACTOR WHERE REQUIRED BY FAILURE TO MEET ORIGINAL TESTS. CONTAMINANTS THAT MAY INHIBIT THE B• II TO THE SUR '. . 14240 HYDRAULIC ELEVATOR 2. CONTRACTOR SHALL FURNISH MATERIALS AND SAMPLES FOR TESTS AND SHALL ASSIST TESTING LABORATORY AS E. INSTALLATION: REQUESTED. A. APPLY MANUFACTURER'S RECOM, DED PRIMER BY MEANS OF R•. ING, SPRAYED OR BROOM APPLICATION IN S c a l e AS NOTED DIMSK21 15 IECHANICM ACCORDANCE OF MANUFACTU' `'S WRITTEN INSTRUCTIONS. END OF SECTION B. MIXING AND INSTALLATIO •F SELF-LEVELING CEMENT BASE TOPPING SH1. BE IN ACCORDANCE OF REFER TO MEP DRAWINGS MANUFACTURER'S WR ' N INSTRUCTIONS. D r a w n B y: DM/AN C. POUR TOPPING , ERIAL ONTO SUBSTRATE AT A THICKNESS OF BETWEEN 1/8" ` 1/2" FOR ALL SURFACES. E DMSION 16 EL RICAI_ TOPPING S ' REACH A COMPRESSIVE STRENGTH OF 5800 PSI AFTER 28 DAYS PE` M C109/MODIFIED [AIR-CU'- 0 NLY]. 2 D. AFT' LAPPING HAS CURED, APPLY A WATER BASED SEALER; LM SCOFIELD SELECTSEAL W I" APPROVED REFER TO MEP DRAWINGS Ew•'L. ONCE SEALER HAS DRIED, FOLLOWED WITH TWO (2) COATS OF INDUSTRIAL STRENGTH W'∎ C:\Temp\AcPubli sh_3148\US220_SPECS.dwg E ONTRACTOR SHALL CONSULT WITH TOPPING MANUFACTURER FOR SPECIFIC PROCEDURES. in M O END OF SECTION Drawing N o. N SPECIFICATIONS CO N O, Q a -a C 0 N _O SRO1 a_ D. CASEWORK: FRAMELESS TYPE AS INDICATED ON DRAWINGS; CUSTOM SINGLE COMPONENT UNITS BASED ON WALL DidMULAMBLISMOS SECTION 08480 - BALANCED ENTRANCE DOORS illa/14 4 [ f �� SPACE USING FIELD MEASUREMENTS. A. GENERAL: PROVIDE BALANCED TYPE ENTRY DOOR SYSTEM, INCLUDING DOORS, FRAMES, TRANSOMS, AND ADJACENT STAINED FINISHED: PREMIUM GRADE VENEER AS APPROVED BY CLIENT. SECTION 08110 - STEEL DOORS AND FRAMES FRAMED GLAZING, HARDWARE, ANCHORAGE, GLAZING, AND ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED 1. TRANSPARENT/ A. GENERAL: PROVIDE STEEL DOORS AND FRAMES, INCLUDING HOLLOW METAL (PRESSED STEEL) FRAMES, AND INSTALLATION. 2. PLASTIC LAMINATE FINISHED: WI/CUSTOM GRADE WITH NEMA LD-3 GENERAL PURPOSE TYPE HIGH PRESSURE ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. 1. ALUMINUM FRAMED STOREFRONT IS SPECIFIED IN SECTION 08410. LAMINATE; FORMICA, LAMINART, OR WILSONART. B. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PERSONS SECTION 05500 - SAL FABRICATIONS 1. COORDINATE WITH SECTION 08700 - HARDWARE. a. HORIZONTAL SURFACES: MINIMUM 0050". WITH DISABILITIES INCLUDING ACCEPTABLE LOCATIONS FOR HAND OPERATED HARDWARE. . A. GENERAL: PROVIDE MISCELLANEOUS METAL SHAPES AND FABRICATIONS AS REQUIRED AND NOT INCLUDED AS PART B. STANDARDS: COMPLY WITH STEEL DOOR INSTITUTE (SDI): SDI-100 (ANSI/SDI A250.8) - RECOMMENDED C. MANUFACTURERS: ELLISON BRONZE CO., INC. OF OTHER SECTIONS WITH ANCHORS AND ACCESSORIES FOR COMPLETE INSTALLATION. b. VERTICAL SURFACES: MINIMUM 0.030". SPECIFICATIONS - STANDARD STEEL DOORS AND FRAMES OR NAAMM HOLLOW METAL MANUFACTURERS ASSOCIATION D. BALANCED ENTRY SYSTEM: COMPLETE ALUMINUM AND GLASS ENTRANCE SYSTEM BASED ON SPECIAL "BALANCED' B. STEEL SHAPES: ASTM A36 STEEL. GLA C. BACK-UP SHEETS: MINIMUM D.D2D "HOLLOW METAL MANUAL." DOOR HARDWARE AND INCLUDING DOORS, FRAMES, SIDELIGHTS, TRANSOMS, ZING, HARDWARE AND ATTACHMENT C. GROUT: PROVIDE NON-SHRINK, NON-METALLIC, PRE-MIXED, FACTORY PACKAGED, NON-STAINING, NON-CORROSIVE, C. MANUFACTURERS: CECO, CURRIES, AMWELD, OR PIONEER. SYSTEM AS INDICATED. NON-GASEOUS GROUT; TYPE SPECIFICALLY RECOMMENDED BY MANUFACTURER FOR APPLICATIONS INDICATED. 3. PARTICLEBOARD: PROVIDE MEDITE CORP. (SIERRAPINE)MEDITE II OR RODMAN INDUSTRIES/RESINCORE I D. HOLLOW METAL DOORS: FLUSH HOLLOW METAL DOORS FULL FLUSH TYPE WITH FILLED EDGE; CLOSE TOP AT 1. DOOR: TYPE AS INDICATED ON DRAWINGS; NOT LESS THAN 10" BOTTOM RAIL. D. GENERAL FABRICATION: GRIND EXPOSED WELDS SMOOTH AND FLUSH WITH ADJACENT SURFACES; COUNTERSINK FORMALDEHYDE-FREE PARTICLEBOARD MADE FROM RECYCLED WOOD PRODUCTS. EXTERIOR DOORS. 2. FINISH: SEE DRAWINGS. FASTENERS; MAKE EXPOSED BUTT JOINTS HAIRLINE JOINTS WHERE MECHANICALLY FASTENED. FIT AND SHOP E. PLASTIC LAMINATE COUNTERTOPS: NEMA LD-3 GENERAL PURPOSE TYPE HIGH PRESSURE PLASTIC LAMINATE BY E. BALANCED DOOR HARDWARE: MANUFACTURER'S STANDARD HEAVY-DUTY HARDWARE CAPABLE OF OPERATING WITHOUT ASSEMBLE IN LARGEST PRACTICAL SECTIONS FOR DELIVERY. 1. CORE: PROVIDE STEEL STIFFENED CORE; INSULATED AT EXTERIOR DOORS. FAILURE OF ANY COMPONENT, FOR NOT LESS THAN 300,000 OPEN AND CLOSE CYCLES, WITH NORMAL FORMICA, LAMINART, OR WILSONART, MINIMUM 0.042" POSTFORMING TYPE WITH 0.020" BACK-UP SHEETS. 2. GAGE: PROVIDE MINIMUM 18 GAGE AT INTERIOR DOORS, MINIMUM 16 GAGE AT EXTERIOR DOORS. E. STEEL RAILINGS: WELDED TYPE WITH 1-1/2" OUTSIDE DIAMETER TUBE HANDRAILS; DESIGNED TO SUPPORT MINIMUM MAINTENANCE. LATERAL FORCE OF 50 LBS/LIN FT UNIFORM LOAD AND 200 LBS AT ANY POINT WITHOUT PERMANENT SET OR F. SOLID POLYMER COUNTERTOPS: COMPARABLE TO WI MOM/PREMIUM GRADE; MANUFACTURER'S STANDARD POLYMER E. PRESSED STEEL (HOLLOW METAL) FRAMES: MINIMUM 16 GAGE WELDED (PRE-ASSEMBLED) FRAMES EXTERIOR, 1. FINISH: BHMA 630 (US32D) SATIN STAINLESS S I LEL WHERE EXPOSED. DAMAGE. SYSTEM WITH COLOR THROUGHOUT THICKNESS; PROVIDE MANUFACTURER RECOMMENDED JOINT ADHESIVE; EXPOSED KNOCK-DOWN (FIELD-ASSEMBLED) FRAMES INTERIOR. F. GLASS: ASTM C1048, KIND FT, SELECT GLAZING QUALITY CLEAR FLOAT GLASS, FULLY TEMPERED SAFETY GLASS US220 1. STANDARDS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ACCESS FOR PERSONS WITH DISABILITIES SURFACES FINISHED TO MATCH TOP. F. FIRE RATED UNITS: CONFORM TO NFPA 80; PROVIDE UL OR WARNOCK HERSEY LABELED DOORS AND FRAMES AS DOOR; NOMINAL 1/4" THICK GLASS. AND WITH NAAMM "PIPE RAILING MANUAL." 1. MANUFACTURERS: DUPONT/CORIAN, AVONITE, FORMICA/SURELL, SWAN/SWANSTONE. REQUIRED. G. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPUCABLE REQUIREMENTS FOR ACCESS FOR WASHINGTON SQUARE F. PRE-ENGINEERED SUPPORT SYSTEMS: UNISTRUT OR GRINNELL/POWERSTRUT MANUFACTURED PRE-ENGINEERED 2. COLOR: MANUFACTURER'S STANDARD COLOR AS SELECTED BY ARCHITECT. G. ACCESSORIES: PROVIDE DOOR SILENCERS, ANCHORS, AND ACCESSORIES. PROVIDE SQUARE GLAZING STOPS AS PERSONS WITH DISABILITIES. SUPPORT SYSTEM CONSISTING OF MINIMUM 12 GAGE "C" CHANNEL SUPPORTS WITH ANCHORS, ATTACHMENTS, AND G. CASEWORK HARDWARE: CHROME OR BRUSHED ALUMINUM FINISH. APPROVED BY ARCHITECT FOR GLAZING IN METAL DOORS AND FRAMES. 9585 S.W. WASHINGTON SQUARE ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. H. FINISH: PRIME PAINT INTERIOR UNITS, GALVANIZE AND PRIME PAINT EXTERIOR UNITS; MINIMUM A60 GALVANIZING; END OF SECTION G. FINISH: PRIME PAINT MISCELLANEOUS METAL. CLEAN SURFACES OF RUST, SCALE, GREASE AND FOREIGN MATTER 1. SHELF SUPPORTS: KNAPE & VOGT 255 STANDARD, 256 SUPPORT; RECESSED. CLEAN, DEGREASE AND FACTORY PRIME PAINT. SUITE H08 PRIOR TO APPLYING GALVANIZED OR PAINTED FINISH. 2. HINGES: EUROPEAN STYLE CONCEALED HINGES. I. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, SDI OR NAAMM STANDARDS, AND APPLICABLE SECTION 08700 - HARDWARE PORTLAND, OR 97223 H. INSTALLATION: INSTALL SQUARE AND LEVEL, ACCURATELY FITTED AND FREE FROM DISTORTION AND DEFECTS. 3. SLIDES: FULL EXTENSION SLIDES, NOT LESS THAN 100 LB. CAPACITY. REQUIREMENTS FOR FIRE RATINGS. A. GENERAL: PROVIDE DOOR HARDWARE FOR HOLLOW METAL AND WOOD DOORS AND PROVIDE CYUNDERS FOR DOORS PROVIDED WITH HARDWARE, WITH ACCESSORIES AS REQUIRED FOR COMPLETE OPERATIONAL DOOR INSTALLATIONS. CLASS: RED END OF SECTION 4. CABINET PULLS: 3" WIRE PULLS. B. STANDARDS: COMPLY WITH BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA) ANSI/ BHMA 156 SERIES 5. LOCKS: REQUIRED AT ALL DOORS AND DRAWERS. END OF SECTION STANDARDS. SECTION 05722 - STAINLESS STEEL AND GLASS RAILINGS H. WOOD PANELING: PREMIUM GRADE PLYWOOD PANELING WITH WHITE BIRCH VENEER FOR OPAQUE PAINT FINISH; C. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PERSONS A. GENERAL: PROVIDE STAINLESS STEEL AND GLASS RAILINGS WITH STAINLESS STEEL POSTS, RAILS, AND COMPONENTS, TONGUE AND GROOVE EDGES. SECTION 08210 - WOOD DOORS WITH DISABILITES. ammooloommommoommul ATTACHMENTS AND ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. A. GENERAL PROVIDE WOOD DOORS AS REQUIRED FOR COMPLETE INSTALLATION; COORDINATE WITH FRAMES AND D. HINGES: FULL MORTISED BUTT HINGES; SIZE AND NUMBER AS RECOMMENDED BY MANUFACTURER; NONREMOVABLE B. QUALITY ASSURANCE: DESIGN TO SUPPORT MINIMUM LATERAL FORCE OF 50 LBS/LIN FT UNIFORM LOAD AND 200 I. TRANSPARENT/STAINED FINISHED WOODWORK: WI/PREMIUM GRADE VENEERS AS INDICATED ON DRAWINGS; VENEERING HARDWARE. PINS AT EXTERIOR OUTSWINGING DOORS, BALL-BEARING HINGES AT FIRE RATED DOORS AND DOORS WITH CLOSERS. LBS AT ANY POINT WITHOUT PERMANENT SET OR DAMAGE. AS DIRECTED BY ARCHITECT WHERE NOT OTHERWISE INDICATED. 1. MANUFACTURERS: HAGER, LAWRENCE, MCKINNEY, OR STANLEY. B. STANDARDS: COMPLY WITH WINDOW AND DOOR MANUFACTURER ASSOCIATION (WDMA) INDUSTRY STANDARDS FOR C. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PERSONS 1. SAND WORK SMOOTH; SEAL, STAIN AND VARNISH CONCEALED AND SEMI-CONCEALED SURFACES OF TRANSPARENT WOOD DOORS. E. LOCKSETS/ LATCHSETS: FULL MORTISE LOCKSETS TYPICAL; SOLID LEVER TYPE WITH ROSE; KEYING AS DIRECTED BY WITH DISABILITIES. FINISHED WOODWORK; BRUSH APPLY. C. MANUFACTURERS: ALGOMA EGGERS OR MARSHFIELD. OWNER; PROVIDE CYUNDERS FOR DOORS FURNISHED WITH LOCKS. D. STAINLESS STEEL COMPONENTS: ASTM A269, GRADE 304; NUMBER 4, BRUSHED FINISH AS DEFINED IN NAAMM'S 2. FINISH: WI/PREMIUM GRADE FINISH AS DIRECTED BY ARCHITECT. " 1. MNUFACTURERS: SCHLAGE, SARGENT, YALE, OR BEST. METAL FINISHES MANUAL. D. FLUSH SOLID CORE DOORS: FIVE PLY 1-3/4 THICK DOORS WITH PAINT GRADE WHITE BIRCH VENEERS AND LUMBER F. OVERHEAD CLOSERS: FULY ADJUSTABLE; MODERN TYPE WITH COVER. J. INSTALLATION: COMPLY WITH INSTITUTE STANDARDS AND MANUFACTURER RECOMMENDATIONS. STAVE CORE OR PARTICLEBOARD CORES; MINERAL CORE PERMITTED AT 45 MINUTE AND HIGHER FIRE RATED UNITS. E. GLASS: ASTM C1048, KIND FT, FULLY TEMPERED SELECT GLAZING QUALITY CLEAR FLOAT GLASS WITH NO EXPOSED 1. MANUFACTURERS: LCN/ 4000 SERIES, NORTON/ 7500, OR DORM'/ TS83U2. TONG OR STRESS MARKS; NOMINAL 1/2" THICK UNLESS OTHERWISE INDICATED; SAFETY GLASS PASSING ANSI Z97.1 E. FIRE RATED UNITS: CONFORM TO NFPA 80; PROVIDE UL OR WARNOCK HERSEY LABELED FRAMES AS REQUIRED. G. ACCESSORIES: PROVIDE DOOR STOPS, THRESHOLDS, WEATHERSTRIPPING, TRIM, COORDINATORS AND ACCESSORIES AS AND ACCEPTABLE TO AUTHORITIES FOR USE IN RAILINGS. END OF SECTION F. ACCESSORIES: PROVIDE TYPE II ADHESIVE FOR INTERIOR APPLICATIONS; PROVIDE MATCHING WOOD GLAZING STOPS AS REQUIRED FOR COMPLETE OPERATIONAL DOOR INSTALLATION. F. GROUT: PROVIDE NON-SHRINK, NON-METALLIC, PRE-MIXED, FACTORY PACKAGED, NON-STAINING, NON-CORROSIVE, APPROVED BY ARCHITECT FOR GLAZING IN WOOD DOORS, 1. GASKETING: PROVIDE COMPLETE ACCOUSTICAL GASKETING FOR DOORS AT MECHANICAL ROOMS, ELECTRICAL ,r NON-GASEOUS GROUT; TYPE SPECIFICALLY RECOMMENDED BY MANUFACTURER FOR APPLICATIONS INDICATED. G. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, WDMA, AND APPLICABLE REQUIREMENTS FOR FIRE ROOMS, AND ELEVATOR EQUIPMENT ROOMS, INCLUDING AUTOMATIC DOOR BOTTOMS. ' r aY1S�1 7 '11 I I tI�E P Idll 84,80 �G. FABRICATION: CONCEAL WELDS AND CONNECTIONS, PROVIDE HAIRLINE JOINTS. RATINGS. H. EXTERIOR HARDWARE FINISH: BHMA 630 (US32D), SATIN FINISHED STAINLESS STEEL. 1. H. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS. *`.,► I. INTERIOR HARDWARE FINISH: GHMA 626 (US26d), SATIN FINISHED CHROMIUM PLATED. ***.N, SECTION 07260 - VAPOR RETARDER END OF SECTION J. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, BHMA, AND APPLICABLE REQUIREMENTS FOR "" END OF SECTION A. GENERAL: PROVIDE SLAB-ON-GRADE VAPOR RETARDER. ACCESS AND FOR FIRE RATINGS. + 8m AID PLASt�S B. MANUFACTURER: FORTIFIBER CORP./MOISTOP ULTRA; STEGO INDUSTRIES, INC./STEGO WRAP (15 MIL); RAVEN END OF SECTION ALAMEDA, A • INDUSTRIES, INC./VAPOR BLOCK # VB 15 (15 MIL BLUE). SECTION 08310 - ACCESS DOORS AND PANELS � - ► SECT101 06105 - MECELLANEOUS ROUGH CARPENTRY C. VAPOR RETARDER: ASTM E1745, CLASS A WATER RESISTANT RETARDER CONSISTING OF 15 MIL POLYOLEFIN FILM. A. GENERAL PROVIDE ACCESS DOORS AS REQUIRED FOR ACCESS TO VALVES AND CONTROLS LOCATED BEHIND s©C1MN OB725 _ L ENERGY DOOR OPERATORS `�� ' A. GENERAL: PROVIDE MISCELLANEOUS BLOCKING AND PLYWOOD. FINISHED WALLS AND CEILINGS NOT OTHERWISE ACCESSIBLE, WITH ACCESSORIES FOR COMPLETE INSTALLATION. A. GENERAL: PROVIDE LOW ENERGY DOOR OPERATORS FOR SWINGING DOORS WITH ACCESSORIES AS REQUIRED FOR OF 011-$ B. STANDARDS: COMPLY WITH AMERICAN INSTITUTE OF TIMBER CONSTRUCTION ('ITC), AMERICAN PLYWOOD ASSOCIATION 1. PERMEANCE: MAXIMUM 0.025 PERMS, ASTM F1249 AND E154 TESTS. B. MANUFACTURERS: MILCOR, J.L INDUSTRIES, OR KARP. COMPLETE OPERATIONAL INSTALLATION; SYSTEM TO OPEN AND CLOSE DOOR UPON RECEIPT OF AN ACTUATING (APA), AND APPUCABLE CODE REQUIREMENTS. D. JOINT SEALER: PRESSURE SENSITIVE TAPE AS RECOMMENDED BY VAPOR RETARDER MANUFACTURER AND PROVIDING C. TYPE: FLUSH TYPE AT NON FIRE RATED CONSTRUCTION, STANDARD UL APPROVED FRAMED TYPE AT FIRE RATED SIGNAL C. BLOCKING: COMPLY WITH PS 20; GRADED BY AN AGENCY CERTIFIED BY FOREST PRODUCTS SOCIETY (FPS) AND OF COMPARABLE PERMEANCE TO VAPOR RETARDER. CONSTRUCTION; KEY OPERATED. 1. PROVIDE AT EXTERIOR ENTRANCE DOORS TO MEET CALIFORNIA REQUIREMENTS FOR ACCESS FOR PERSONS WITH TYPE RECOMMENDED FOR APPLICATION INVOLVED; DOUGLAS FIR OR SOUTHERN PINE; MINIMUM CONSTRUCTION GRADE E. SAND BED: CLEAN DRY NATURAL SAND; FREE FROM SILT, CLAY, LOAM, FRIABLE OR SOLUBLE MATERIALS, AND D. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE REQUIREMENTS FOR FIRE RATINGS. DISABILITIES. S-DRY. ORGANIC MATTER. B. STANDARDS: COMPLY WITH BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA) ANSI/BHMA 156.19. wommomonomommoni D. PLYWOOD: COMPLY WITH PS 1, AND APPLICABLE APA PERFORMANCE STANDARDS FOR TYPE OF PANEL AND F. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS; TAPE JOINTS AND TEARS IN VAPOR RETARDER. END OF SECTION C. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PERSONS APPLICATION INDICATED. WITH DISABILITIES. E. TREATED WOOD: PRESSURE TREAT WOOD IN CONTACT WITH CONCRETE AND AT ROOFING; FIRE TREAT WOOD SECTION 08335 - OVER/DD COIUNIG D. LOW ENERGY DOOR OPERATORS: COMPLETE OPERATOR SYSTEM INCLUDING DOOR OPERATOR, CONTROLS, AND END OF SECTION CONCEALED IN INTERIOR WHERE REQUIRED BY APPLICABLE AUTHORITIES. ATTACHMENT SYSTEM DESIGNED FOR TYPE OF DOORS INDICATED AND COMPLYING WITH REQUIREMENTS OF ANSI 1. PRESSURE TREATED: WATER-BORNE PRESERVATIVES FOR ABOVE GROUND USE CONFORMING TO AWPA C2 AND C9. A. GENERAL: PROVIDE OVERHEAD COILING GRILLES WITH ACCESSORIES AS REQUIRED FOR COMPLETE OPERATIONAL A156.19 FOR LOW ENERGY POWER OPERATED DOOR OPERATORS. 2. FIRE TREATED: CONFORM TO AWPA C20 AND C27, INTERIOR TYPE A AT INTERIOR APPLICATIONS; PASS ASTM SECTION 075®0 - ROW' RIMS INSTALLATION. 1. MANUFACTURERS: HORTON AUTOMATICS/SERIES 7000; LCN/4600 SERIES ELECTRICALLY POWERED D2898 RAIN TEST WHERE AT EXTERIOR WALLS AND ROOF; IDENTIFY WITH FRTW. 8. MANUFACTURERS: COOKSON, OVERHEAD, WAYNE DALTON/ NORTH AMERICAN, OR METRO DOOR. AUTO-EQUALIZER; DOR-O-MATIC, INC./SENIOR-SWING AUTOMATIC OPERATION. 3. KILN-DRY TREATED WOOD TO 19% MOISTURE CONTENT; DISCARD WARPED AND DAMAGED PIECES. A. GENERAL: REPAIR EXISTING ROOFING SYSTEM AS REQUIRED FOR NEW CONSTRUCTION WITH ACCESSORIES FOR C. TYPE: ALUMINUM, STRAIGHT LINK, ELECTRICALLY OPERATED TYPE WITH SAFETY RELEASE FOR EMERGENCY EXITING. E. ACCESSORIES: PROVIDE ACCESSORIES AS REQUIRED FOR COMPLETE OPERATIONAL INSTALLATION. F. FASTENERS: GALVANIZED AT EXTERIOR LOCATIONS AND PRESSURE TREATED WOOD; SIZE AND TYPE TO SUIT COMPLETE WEATHERTIGHT INSTALLATION. D. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS. F. FINISH: AS DIRECTED BY ARCHITECT BASED ON APPLICATION INVOLVED; PRIME PAINTED AT STEEL AND AT WOOD APPLICATION; PROVIDE WASHERS FOR NUTS AND BOLTS. B. STANDARDS: CONFORM TO NATIONAL ROOFING CONTRACTOR'S ASSOCIATION ROOFING AND WATERPROOFING MANUAL, DOORS, CLEAR ANODIZED ALUMINUM AT ALUMINUM AND GLASS DOORS. Dil G. INSTALLATION: COMPLY WITH REFERENCED STANDARDS AND APPLICABLE CODE REQUIREMENTS. 4TH OR 5TH EDITION. END OF SECTION G. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, BHMA, AND APPUCABLE REQUIREMENTS FOR D e n n i s Heath, A r c h i t e c t END OF SECTION C. WARRANTY: PROVIDE FOR CORRECTING FAILURE OF ROOF REPAIRS TO RESIST PENETRATION OF WATER AND DAMAGE ACCESS FOR PERSONS WITH DISABILITIES. 24/0 Mariner Square loop FROM WIND; WARRANTY PERIOD OF TWO YEARS. END OF SECTION Alameda, CA 94501 SEA 06200 - MEN CARPENTRY 1. WHERE EXISTING BUILDING HAS WARRANTY COMPLY WITH REQUIREMENTS OF EXISTING ROOF WARRANTY FOR ''+t a 08410 - ALUMINLBII FRAMED STOREFRONTS A. GENERAL: PROVIDE WOOD TRIM INCLUDING WOOD DOOR JAMBS, WOOD SHELVING, CLOSET POLES, COATED WIRE REPAIRS. A. GE • PROVIDE EXTRUDED ALUMINUM ENTRANCE SYSTEM WITH DOORS, FRAMES, HARDWARE, AND ' ORIES SECTION 08800 - GLAZING CLOSET POLES, MOP HOLDERS, AND ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. D. ROOFING SYSTEM: MATCH EXISTING ROOFING, NO SUBSTITUTIONS PERMITTED; PROVIDE MATERIALS CAPABLE OF AS REQUI' ; OR COMPLETE WEATHERTIGHT INSTALLATION. A. GENERAL: PROVIDE GLASS AND GLAZING ACCESSORIES NOT PROVIDED ELSEWHERE AND AS REQUIRED FOR COMPLETE B. STANDARDS: CONFORM TO WOODWORK INSTITUTE (WI) "MANUAL OF MILLWORK" STANDARDS OR ARCHITECTURAL MAINTAINING EXISTING WARRANTIES; CONFORM TO REQUIREMENTS OF NRCA ROOFING MANUAL AND APPUCABLE CODE B. STANDARDS: COMP I H ARCHITECTURAL ALUMINUM MANUFACTURERS ASSOCIATION (.• ALUMINUM STORE INSTALLATION. WOODWORK INSTITUTE (Awl) "QUALITY STANDARDS" AND APPLICABLE CODES. REQUIREMENTS. FRONT AND ENTRANCE MA'• ' " B. STANDARDS: COMPLY WITH FLAT GLASS MARKETING ASSOCIATION (FGMA) "GLAZING MANUAL" AND "GLAZING SEALING C. OPAQUE PAINTED WOOD TRIM: CUSTOM GRADE; POPLAR OR WHITE BIRCH (MDF NOT ACCEPTABLE). 1. SYSTEM: PROVIDE COMPLETE SYSTEM WITH ACCESSORIES AS REQUIRED FOR REPAIRS. C. CODES AND REGULATIONS: COMPL' I H S T A T E AND FEDERAL REQUIRE FOR ENSURING ACCESS FOR PERSONS SYSTEMS MANUAL." D r a w i n g s g a d w r i t t e n m a t e r i a l a p p e a r i n g h e r e i n c o n s t i t u t e a r i g i a a l D. WOOD SHELVING: WI/CUSTOM GRADE, 3/4" WOOD BOARD OR HARDWOOD-EDGED PLYWOOD. E. ROOF SYSTEM REPAIRS: COMPLY WITH MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS AND NRCA WITH DISABILITIES INCLUDING ACCEPTABL • ATIONS FOR HAND I' •TED HARDWARE. C. CODES: SAFETY GLAZING SHALL COMPLY WITH CONSUMER PRODUCT STANDARD 16 CFR 1201, AND SHALL HAVE a n d u n p u b l i s h e d y o l k of t h e A r c h i t e c t a n d m a y not be duplicated, 1. ADJUSTABLE SUPPORTS: HEAVY DUTY TYPE WITH SINGLE SLOTS 2" ON CENTER, 12" STANDARDS UNLESS RECOMMENDATIONS FOR ROOF TYPE SPECIFIED. PASSED ANSI Z97.1. u s e d a r d i s c l o s e d w i t h o u t w r i t t e a c o n s e n t of t h e A r c h i t e c t D. MANUFACTURERS: KAWNEER, VISTAWALL, OR AR OTHERWISE INDICATED; FINISH AS SELECTED BY ARCHITECT FROM STANDARD FINISHES. E. TYPE: MANUFACTURER'S STANDARD EXTRUDED ALU • ••NCE SYSTEM WITH PROFILES AS INDICATED ON D. MANUFACTURERS: PPG, PILKINGTON, OR NIPPON. c®D H ARCHITECTS- 2 010 E. JANITOR CLOSET MOP HOLDERS: SPRING LOADED ANTI-SLIP MOP HOLDERS WITH RUBBER CAM, WITH THREE MOP E. TEMPERED GLASS: ASTM C1048, KIND FT, FULLY TEMPERED, SELECT GLAZING QUALITY; SAFETY GLASS; NOMINAL HOLDERS ON STAINLESS STEEL. END OF SECTION DRAWINGS. 3/4" UNLESS OTHERWISE INDICATED. 1. MANUFACTURERS: BOBRICK WASHROOM EQUIPMENT, INC./MODEL B-223; BRADLEY CORP./MODEL 9953; AMERICAN 1. DOOR TYPE: AS INDICATED ON a GS; WITH NOT LESS THAN 10 ;14 OM RAIL F. CLEAR FIRE RATED GLASS: UL LISTED FOR FIRE RESISTANCE AND TESTED AND APPROVED FOR IMPACT RESISTANCE QM Q C SPECIALTIES INC./MODEL 0796A. SECnON 07810 - S P R A Y E D-O N FR:P'ROOFTNG 2. DOOR HARDWARE: AS AP•':f D B Y ARCHITECT. BASED ON ANSI Z97.1; NOMINAL 3/4" THICK. N o . D o t e I s s u e F. ACCESSORIES: PROVIDE AS INDICATED, AS RECOMMENDED BY WOODWORK INSTITUTE FOR APPLICATIONS INDICATED, 3. ENTRANCE SYSTE, ' SH: SEE DRAWINGS. G. FRAMELESS MIRRORS: ASTM C1036 MIRROR QUALITY Q2 CLEAR FLOAT GLASS; FULL SILVER COATING, COPPER AND AS REQUIRED FOR COMPLETE INSTALLATION AS INDICATED. A. GENERAL: CEMENTITIOUS OR MINERAL FIBER SPRAY-ON FIREPROOFING AS REQUIRED BY APPLICABLE CODES FOR F. INSTALLATIO • '. PLY WITH MANUFACTURER RECOMMENDATIONS AND 'AMA STANDARDS. COATING AND ORGANIC COATING; NOMINAL 1/4" THICK. 05/28/10 100% SET TYPE I FIRE RESISTIVE CONSTRUCTION; NO ASBESTOS PERMITTED. G. INSTALLATION: INSTALL WORK CONSISTENT WITH SPECIFIED WI MOM QUALITY GRADE, PLUMB, LEVEL, TRUE AND H. GLAZING SEALANT: DOW, GE, OR TREMCO; ONE COMPONENT SIUCONE GLAZING SEALANT; PROVIDE AS RECOMMENDED 05/28/10 VT PACKAGE STRAIGHT WITH NO DISTORTIONS; SHIM AS REQUIRED, USING CONCEALED SHIMS. B. MANUFACTURERS: W.R. GRACE/MONOKOTE OR ALBI MANUFACTURING DIVISION STANCHEM/DURASPRAY. END OF SECTION BY SEALANT MANUFACTURER FOR APPLICATIONS INDICATED.1. INSTALL TRIM IN SINGLE, UNJOINTED LENGTHS FOR OPENINGS AND FOR RUNS LESS THAN 10'-0"; FOR LONGER C. INSTALLATION: INSTALL IN ACCORDANCE MANUFACTURER RECOMMENDATIONS AND FIRE TEST RESULTS AS REQUIRED I. SETTING BLOCKS AND SPACERS: NEOPRENE OR EPDM, SILICONE COMPATIBLE WHERE IN CONTACT WITH SILICONE 07/02/10 100 COMPLETE SET RUNS USE ONLY ONE PIECE LESS THAN 10'-0"; PROVIDE SCARF JOINTS BETWEEN MEMBERS, STAGGER JOINTS IN TO PROVIDE REQUIRED FIRE RATINGS. 08450 - ALL-gaSS ENTRANCES AND STOIEFRONTS 28 10 SEALANT. ADJACENT MEMBERS; MITER CORNERS; NOT LESS THAN TWO FASTENERS EACH. J. INSTALLATION: COMPLY WITH GLASS MANUFACTURER RECOMMENDATIONS, FGMA, AND APPLICABLE CODES; METAL 07/ / LANDLORD SET A. GENERAL PROVIDE ALL-GLASS ENTRANCES INCLUDING DOORS, SIDELIGHTS, SIDELIGHT FRAMING, HARDWARE AND SHALL NOT TOUCH GLASS. H. PREPARATION FOR FIELD FINISHING: SAND WORK SMOOTH AND SET EXPOSED NAILS AND SCREWS; APPLY WOOD END OF SECTION ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION; COORDINATE WITH ADJACENT CONSTRUCTION. 08/13/10 PERMIT/BID SET FILLER IN EXPOSED NAIL AND SCREW INDENTATIONS AND LEAVE READY TO RECEIVE SITE-APPLIED FINISHES. 1. SEAL CONCEALED AND SEMI-CONCEALED SURFACES; BRUSH APPLY ONLY, USING PRIMER CONSISTENT WITH FINISH B. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PERSONS END OF SECTION COATS SPECIFIED UNDER SECTION 09900 - PAINTS AND COATINGS. SECTION 07840 - MEWL:WPM WITH DISABILITIES INCLUDING ACCEPTABLE LOCATIONS FOR HAND OPERATED HARDWARE. C. MANUFACTURERS: BLUMCRAFT, VIRGINIA GLASS, OR BRITE VUE. END OF SECTION A. GENERAL: PROVIDE PENETRATION-TYPE FIRESTOPPING FOR TIME-RATED FLOOR, WALL, AND PARTITION ASSEMBLIES D. TYPE: ASTM C1048, KIND FT, FULLY TEMPERED SAFETY GLASS DOOR AND SIDELIGHT SYSTEM WITH CONCEALED CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE AND HOT GASES. CLOSERS, PIVOTS, PUSH/PULLS, THRESHOLDS, AND ELECTROMAGNETIC LOCK HARDWARE; MINIMUM 1/2" THICK SECTION 06400 - ARCHITECTURAL WOODWORK B. CODES: CONFORM TO APPLICABLE CODE REQUIREMENTS FOR BOTH F AND T RATINGS. GLASS. A. GENERAL: PROVIDE WOOD CASEWORK AND COUNTERTOPS, WOOD PANELING, AND ACCESSORIES AS REQUIRED FOR C. STANDARDS: PASS ASTM E814 THROUGH-PENETRATION FIRE STOPS, ASTM E119 FIRE TESTS AND ASTM E84 FLAME 1. EXPOSED METAL FINISH: NO. 4 SATIN DIRECTIONAL POLISHED STAINLESS STEEL, NOT LESS THAN TYPE 304 FOR COMPLETE FINISHED INSTALLATION. SPREAD/SMOKE CONTRIBUTION MAXIMUM 25/25. INTERIOR LOCATIONS, TYPE 316 FOR EXTERIOR LOCATIONS. B. STANDARDS: CONFORM TO WOODWORK INSTITUTE (WI) "MANUAL OF MILLWORK" OR ARCHITECTURAL WOODWORK D. MANUFACTURERS: 3M/FIRE BARRIER, STI/SPECSEAL OR PENSIL, OR HILTI/FIRESTOP SYSTEMS. E. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE REQUIREMENTS FOR ACCESS FOR INSTITUTE (AWL) "QUALITY STANDARDS'; PREMIUM GRADE UNLESS OTHERWISE INDICATED. PERSONS WITH DISABILITIES. 1. CERTIFICATION: PROVIDE CERTIFICATION. E. INSTALLATION: INSTALL IN ACCORDANCE MANUFACTURER RECOMMENDATIONS AND FIRE TEST RESULTS AS REQUIRED C. MANUFACTURERS: MEMBERS OF WOODWORK INSTITUTE (WI) OR ARCHITECTURAL WOODWORK INSTITUTE (AWL) WITH TO PROVIDE REQUIRED FIRE RATINGS. END OF SECTION MINIMUM FIVE YEARS SUCCESSFUL EXPERIENCE FABRICATING ARCHITECTURAL WOODWORK SIMILAR TO THAT REQUIRED FOR PROJECT. END OF SECTION :641. ( 60 - AUTDMATD ENTRANCE DOORS A. GEN • PROVIDE AUTOMATIC ENTRANCE SYSTEMS INCLUDING DOORS, FRAMES, OEPRATORS, DETECTO: , . D SECTION 07900 - DINT SEALERS ACCESSOR REQUIRED FOR COMPLETE OPERATIONAL WEATHER TIGHT INSTALLATION. A. GENERAL: PROVIDE EXTERIOR AND INTERIOR JOINT SEALERS NOT PROVIDED ELSEWHERE; TYPE SUITABLE FOR B. STANDARDS: COMPL I H ANSI/ BHMA '156.10 POWER OPERATED PEDESTRIAN DOOR APPLICATION INDICATED WITH ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. C. MANUFACTURERS: ACCESS - -6,OLOGIES-STANLEY WORKS/ AUTO-SLIDE WITH , -SCAN DETECTOR, B. VERIFICATION: MANUFACTURER REPRESENTATIVE TO REVIEW PROJECT AND VERIFY IN WRITING JOINT SEALERS ARE DOR-O-MATIC/ ASTRO-SLIDE, OR ON/ ELECTRIC SLIDE. COMPATIBLE WITH SUBSTRATES AND WITH APPUCATIONS INDICATED. D. TYPE: EXTRUDED ALUMINUM AND GLASS A = IC (ELECTRO-t ''•NICAL) SLIDING DOOR SYSTEMS TO MATCH C. ELASTOMERIC SEALANTS: ALUMINUM ENTRANCES AND STOREFRONTS; OPE'• : • , • ION DETECTOR; WITH RELATED TRIM AND FLUSH GLAZING. 1. EXTERIOR NON-TRAFFIC JOINTS: GE/SILPRUF, DOW/790-795, OR PECORA/854, LOW MODULUS SILICONE SEALANT. 1. FINISH: MATCH ALUMINUM WINDOWS. 2. TRAFFIC BEARING JOINTS: MAMECO/VULKEM 245, OR PECORA/NR-200 UREXPAN, MULTI-COMPONENT 2. PANIC DEVICE: PROVIDE EMERG ■ ' :REAKAWAY SWING FEATURE WI - LF-CLOSING FEATURE, SAFETY RELEASE Project N o. 44122 POLYURETHANE, SELF-LEVELING JOINT SEALER. CLUTCH FOR OBSTRUCT w ' •SING, AND ELECTRICAL INTERLOCKS TO PR t OPERATION WHEN DOORS ARE ■- 3. MILDEW-RESISTANT SANITARY SEALANTS: GE/SANITARY SEALANT, DOW/BATHTUB CAULK, OR PECORA/863 #345 LOCKED. WHITE; PROVIDE A T INTERIOR AREAS WHERE SEALANT WILL BE EXPOSED TO WATER. E. INSTALLATION.. ■•LY WITH MANUFACTURER RECOMMENDATIONS AND ANSI/ BHMA. S c a l e AS NOTED D. NON-ELASTOMERIC SEALANTS: .- AC-20 OR SONNEBORN/SONOLAC, ACRYLIC OR LATEX EMULSION. END OF SECTION 1. GENERAL INTERIOR JOINT SEALER: PECORA/AC-20 / DrawnBy: DM/AN E. MISCELLANEOUS MATERIALS: PRIMERS, SEALERS, JOINT CLEANERS, BOND BREAKER TAPE, AND SEALANT BACKER RODS 0 AS RECOMMENDED BY SEALANT MANUFACTURER FOR APPLICATIONS INDICATED. 0 cp 1. OVERSIZE BACKER ROD MINIMUM 30% TO 50% OF JOINT OPENING. 0 F. PREPARATION: CLEAN JOINT SURFACES IMMEDIATELY BEFORE INSTALLATION OF JOINT SEALER, AND PRIME OR SEAL C:\Temp\AcPublish_3148\US220_SPECS.dwg JOINT SURFACES AS RECOMMENDED BY MANUFACTURER. G. INSTALLATION: COMPLY WITH MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS AND ASTM C1193. "' Drawing No. a 1. EMPLOY INSTALLATION TECHNIQUES WHICH WILL ENSURE JOINT SEALERS ARE DEPOSITED IN UNIFORM, CONTINUOUS N RIBBONS WITHOUT GAPS OR AIR POCKETS, WITH COMPLETE "WETTING" OF BOND SURFACES. SPECIFICATIONS N END OF SECTION 0 0 0 M t SRO2 ..V F SECTION 09900 - PAINTS AND COATINGS �ASEI 11 EOtJF T /1/43A/ A. GENERAL: PROVIDE PAINTING OF EXPOSED ITEMS AND SURFACES NOT PREFINISHED, AS REQUIRED FOR COMPLETE SECTION 09260 - GYPSUM BOARD ASSEMBLIES FINISHED INSTALLATION. 11452 - APPLIANCES A. GENERAL: PROVIDE GYPSUM BOARD SYSTEMS INCLUDING LIGHT GAGE (20 GAGE AND UGHTER) METAL FRAMING, 1. SURFACES NOT TO BE PAINTED: PREFINISHED ITEMS; CONCEALED AREAS, CODE-REQUIRED LABELS. GYPSUM BOARD, JOINT TREATMENT, ACOUSTICAL INSULATION, ACOUSTICAL SEALANT, AND ACCESSORIES AS REQUIRED B. SUBMITTALS: FURNISH PRODUCT DATA AND SAMPLES. DUPUCATE PAINTED FINISHES OF APPROVED SAMPLES ON A. GENERAL: PROVIDE APPLIANCES WITH ACCESSORIES AS REQUIRED FOR COMPLETE OPERATIONAL INSTALLATION. FOR COMPLETE INSTALLATION. ACTUAL WALL SURFACES AND COMPONENTS FOR APPROVAL PRIOR TO COMMENCING WORK. B. MANUFACTURERS: FRIGIDAIRE, GENERAL ELECTRIC, HOTPOINT, WHIRLPOOL, OR IN-SINK-ERATOR. B. STANDARDS: PERFORM GYPSUM BOARD SYSTEMS WORK IN ACCORDANCE WITH OF ASTM C754 AND ASTM C840 C. STANDARDS: PROVIDE MATERIALS APPROVED FOR USE BY APPLICABLE AIR QUALITY MANAGEMENT DISTRICT FOR C. APPLIANCES: PROVIDE APPLIANCES EACH AS COMPLETE UNIT WITH OPTIONS AND ACCESSORIES AS DIRECTED AND AS UNLESS OTHERWISE SPECIFIED. LIMITATIONS OF VOLATILE ORGANIC COMPOUNDS FOR ARCHITECTURAL COATINGS. REQUIRED FOR COMPLETE OPERATIONAL CODE COMPLIANT INSTALLATION. 1. FIRE-RATED ASSEMBLIES: LISTED BY UL, GYPSUM ASSOCIATION (GA) FILE NO'S IN GA-600 FIRE RESISTANCE D. MANUFACTURERS: BENJAMIN MOORE; CUSTOM COLORS AS DIRECTED BY ARCHITECT. DESIGN MANUAL, OR OTHER LISTING APPROVED BY APPLICABLE AUTHORITIES. E. MATERIAL QUALITY: PROVIDE TOP LINE QUALITY COMMERCIAL GRADE (PROFESSIONAL PAINTER) PAINTS; MATERIALS NOT 1. TYPES: REFER TO DRAWINGS FOR APPLIANCES. C. SYSTEMS RESPONSIBILITY: PROVIDE PRODUCTS MANUFACTURED BY OR RECOMMENDED BY MANUFACTURER OF GYPSUM BEARING MANUFACTURER'S IDENTIFICATION AS A BEST-GRADE PRODUCT NOT ACCEPTABLE. D. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS. BOARD TO MAINTAIN SINGLE-SOURCE RESPONSIBILITY FOR SYSTEM. 1. PRIMERS: PROVIDE PREMIUM GRADE PRIMERS RECOMMENDED BY PAINT MANUFACTURER FOR SUBSTRATES 1. OPENINGS: OBTAIN DIMENSIONS AND LOCATIONS FROM OTHER TRADES AND PROVIDE OPENINGS AND ENCLOSURES INDICATED AND FOR FINISH SYSTEMS SPECIFIED. END OF SECTION FOR ACCESSORIES, SPECIALTIES, EQUIPMENT, AND DUCTWORK. 2. UNDERCOATS AND BARRIER COATS: PROVIDE UNDERCOAT PAINTS PRODUCED BY SAME MANUFACTURER AS FINISH D. SUBMITTALS: SUBMIT PRODUCT DATA AND SAMPLES OF SPECIAL TEXTURE. COATS; USE ONLY THINNERS APPROVED BY PAINT MANUFACTURER, AND USE ONLY WITHIN RECOMMENDED LIMITS. E. MANUFACTURERS: USG, GEORGIA PACIFIC, OR NATIONAL GYPSUM. 3. COLORS AND FINISHES: PRIOR TO COMMENCEMENT OF PAINTING WORK, ARCHITECT WILL FURNISH COLOR CHIPS ingii-MBRMIGLeigUISM F. LIGHT GAGE METAL (STUD) FRAMING: CONFORM TO ASTM C754; COMPLETE 20 GAGE AND LIGHTER STEEL FRAMING FOR SURFACES TO BE PAINTED. AND SUSPENSION SYSTEM FOR GYPSUM BOARD SYSTEMS. F. PREPARATION: PERFORM PREPARATION AND CLEANING PROCEDURES IN ACCORDANCE WITH PAINT MANUFACTURER'S US220 1. RESILIENT CHANNELS: SCREW-TYPE RESILIENT CHANNELS WHERE INDICATED AND WHERE REQUIRED TO PROVIDE INSTRUCTIONS AND AS SPECIFIED FOR SUBSTRATE CONDITION. REMOVE ITEMS IN PLACE AND NOT TO BE PAINTED, ONSOLLUESZUMMIUGELOCUM REQUIRED SOUND TRANSMISSION AND IMPACT ISOLATION CLASSIFICATIONS. OR PROVIDE PROTECTION; AFTER PAINTING REINSTALL ITEMS. WASHINGTON SQUARE G. GYPSUM BOARD MATERIALS: PROVIDE MATERIALS IN ACCORDANCE WITH ASTM C840. G. APPUCATION: APPLY PAINT IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS; USE APPLICATORS AND TECHNIQUES ONSULainittairaMigi 1. GYPSUM BOARD: ASTM C36, TYPE X ARE RATED; COMPLY WITH ASTM C840; MAXIMUM PERMISSIBLE LENGTHS; BEST SUITED FOR SUBSTRATE AND TYPE OF MATERIAL BEING APPLIED. APPLY ADDITIONAL COATS WHEN STAINS OR 9585 S.W. WASHINGTON SQUARE ENDS SQUARE CUT, TAPERED EDGES ON BOARDS TO BE FINISHED. BLEMISHES SHOW THROUGH FINAL COAT, UNTIL PAINT IS UNIFORM APPEARANCE. ''2 + 14240 HYDRALAJC ELEVATOR SUITE H08 2. TILE SUBSTRATE: CEMENTITIOUS BACKER UNITS SPECIFIED IN SECTION 09300 - TILE. 1. FINISH DOORS ON TOPS, BOTTOMS AND SIDE EDGES SAME AS FACES. H. GYPSUM BOARD ACCESSORIES: COMPLY WITH ASTM C840. H. MINIMUM COATING THICKNESS: APPLY AT NOT LESS THAN MANUFACTURER'S RECOMMENDED SPREADING RATE, TO A. ERAL: PROVIDE HYDRAULIC ELEVATOR AND ACCESSORIES AS REQUIRED FOR COMPLETE OPERATIONAL FINI -ED PORTLAND, OR 97223 I. ACOUSTICAL ACCESSORIES: ASTM C665, TYPE I UNFACED ACOUSTICAL INSULATION, ASTM C919 ACOUSTICAL SEALANT; ESTABLISH DRY FILM THICKNESS AS RECOMMENDED BY COATING MANUFACTURER. IN 'TION. AND OUTLET, SWITCH, AND TELEPHONE BOX ACOUSTICAL PADS. I. PRIME COATS: APPLY TO ITEMS NOT PREVIOUSLY PRIMED; RECOAT PRIMED AND SEALED SURFACES WHERE THERE IS B. STAND'' : COMPLY WITH ANSI A17.1, SAFETY CODE FORE ELEVATORS, AND WITH NDPA 70, NATIO ELECTRICAL CLASS: RED J. GYPSUM BOARD INSTALLATION: INSTALL IN ACCORDANCE WITH ASTM C840 AND MANUFACTURER'S RECOMMENDATIONS; EVIDENCE OF SUCTION SPOTS OR UNSEALED AREAS IN FIRST COAT. CODE. USE SCREWS WHEN FASTENING GYPSUM BOARD; COMPLY WITH GYPSUM ASSOCIATION "LEVELS OF GYPSUM BOARD J. FINISH COATS: PROVIDE EVEN TEXTURE; LEAVE NO LAPS, IRREGULARITY IN TEXTURE, SKID MARKS, OR OTHER C. CODES AND R ► LATIONS: COMPLY WITH APPLICABLE CODES AND REGULATIONS FOR ELEVATO' INCLUDING FINISH"; PROVIDE FIRE RATED SYSTEMS WHERE INDICATED. SURFACE IMPERFECTIONS. REQUIREMENTS FO' •ROVIDING ACCESS FOR PERSONS WITH DISABILITES. 1. FINISH: GA LEVEL 4, THREE COAT FINISHING AND SANDING IS REQUIRED FOR SURFACES INDICATED TO BE K. PAINT SYSTEMS: PROVIDE MINIMUM TWO COAT PLUS PRIMER SYSTEMS. 1. AMBULANCE GURN CCESS: COMPLY WITH CALIFORNIA REQUIREMENTS FOR ACC 0 ONE ELEVATOR SERVING PAINTED; PROVIDE FLUSH, SMOOTH JOINTS AND SURFACES READY FOR PAINT FINISHES. 1. GYPSUM BOARD WALLS: EGGSHELL (SATIN) LATEX EMULSION. EACH FLOOR. K. ACOUSTICAL ACCESSORIES INSTALLATION. COMPLY WITH MANUFACTURER RECOMMENDATIONS AS REQUIRED TO ACHIEVE 2. GYPSUM BOARD CEILINGS: FLAT LATEX EMULSION. STC RATINGS INDICATED. 3. TOILET ROOM WALLS AND CEILINGS: SEMIGLOSS ACRYLIC ENAMEL. D. MANUFACTURERS: OTIS ELEVA .• CO., UNITED TECHNOLOGIES; SHINDLER ELEV' CORP.; OR THYSSEN KRUPP 4. PAINTED METAL: SEMIGLOSS 100% ACRYLIC. ELEVATORS. END OF SECTION 5. OPAQUE PAINTED WOOD: SEMIGLOSS 100% ACRYLIC. E. TYPE: COMPLETE OPERATIONAL SYST FOR PLUNGER TYPE HUDRAULIC ''PE ELEVATORS, INCLUDING GUIDE RAILS - , 6. TRANSPARENT FINISHED WOOD: SATIN ACRYLIC-URETHANE. AND BRACKETS, CYLINDER AND PLUNGE', HYDRAULIC FLUID RESERV0 PIT BUFFERS; AND REQUIRED HARDWARE SECTIN 09300 L. PREPARATION AND APPLICATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS FOR TYPES OF SUBSTRATES AND AND FITTINGS. A. GENERAL: PROVIDE CERAMIC AND STONE TILE SYSTEMS INCLUDING SETTING MATERIALS, GROUT, AND ACCESSORIES AS SPECIFIED PAINT SYSTEMS. 1. PROVIDE DRILLED HOLE AND CASING FOR C DER, INCL % G CONCRETE FILL AND CATHODIC PROTECTION FOR REQUIRED FOR COMPLETE FINISHED INSTALLATION. " METALLIC CYLINDERS IF USED. B. STANDARDS: COMPLY WITH TILE COUNCIL OF NORTH AMERICA "HANDBOOK OF CERAMIC TILE INSTALLATION INCLUDING END OF SECTION ) iI REFERENCED ASTM AND ANSI STANDARDS. F. ELEVATOR CHARACTERISTICS: COMPY WITH FOLLOWING , ' ESS OTHERWISE INDICATED. f fr C. TILE: TYPES AS INDICATED ON FINISH SCHEDULE. 1. WEIGHT CAPACITY: 2500 LBS. � L l 10 SPE�Mt.'� 1. OWNER FURNISHED TILE: COORDINATE DIRECTLY WITH OWNER. '' -%41,;dii-�� E I.v(' '2. MARBLE SADDLES: HONED FINISH, PREMIUM GRADE VERMONT OR GEORGIA WHITE MARBLE AS APPROVED BY SECTION 10440 - SIGNAT�E 2. SPEED. 125 TO 150 FPM. el ARCHITECT; FREE OF CRACKS, FLAWS, AND DEFECTS; COMPLY WITH APPLICABLE STATE AND FEDERAL A. GENERAL: PROVIDE GENERAL SIGNAGE INCLUDING ENTRY SIGNS, TOILET ROOM SIGNS, STAIR SIGNS, AND BRAILLE EXIT 3. CONTROL: MICRO PROCESSOR CONTRO D SELECTIVE COLLECTI • OPERATION WITH STARTER. p�,, REQUIREMENTS FOR ACCESS FOR CONNECTION OF ADJACENT FLOOR FINISHES. G. ELEVATOR FINISHES: • • SIGNS AS REQUIRED BY APPLICABLE CODES AND STANDARDS. ALAMEDA.CA 3. FLOOR TILE: PROVIDE NON-SLIP UNITS WITH MINIMUM WET AND DRY VALUE COEFFICIENT OF FRICTION OF NOT B. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PERSONS 1. HOISTWAY DOORS AND FRAME TAINLESS STEEL, NUMBER 4 FINISH. ‘1,' . .,(P LESS THAN 0.60, ASTM C1028. WITH DISABILITIES. D. LATEX THIN SET: THINSET BOND COAT, LATEX-CEMENTITIOUS MORTAR CONFORMING TO ANSI A118.4. C. MANUFACTURERS: ASI SIGN SYSTEMS, MOHAWK, VOMAR, OR CAMEO. 2. CAB DOOR/ FRONT PANE :. STAINLESS STEEL WITH INTEGRAL CONTROL PAN 14 Q E. GROUT: LATICRETE/LATAPDXY 700 SERIES SP-100 STAINLESS EPDXY GROUT, UNIFORM IN COLOR, RESISTANT TO D. ENTRY SIGNS: VINYL PRESSURE SENSITIVE SIGNS. 3. CAB SIDE AND BACK 'LS: PLASTIC LAMINATE. OF v SHRINKAGE; COLOR TO MATCH TILE UNLESS OTHERWISE INDICATED. E. TOILET ROOM DOOR SIGNS: PLASTIC; TWO SIGNS REQUIRED FOR EACH TOILET ROOM, ONE SIGN ON THE DOOR TO 4. CEILING: STAINLE - STEEL WITH DOWNUGHTS. F. WATERPROOF MEMBRANE: LATICRETE, BOSTIK, MER-KOTE, OR NOBEL; MANUFACTURER'S STANDARD SYSTEM DESIGNED COMPLY WITH CALIFORNIA REQUIREMENTS, ONE SIGN ADJACENT TO THE DOOR TO COMPLY WITH ADAAG; WITH FOR APPLICATION UNDER THIN SET TILE IN NON-IMMERSED APPLICATIONS. BRAILLE. 5. FLOORING: C,., ET PROVIDED UNDER SECTION 09680 - CARPETING. G. CEMENTITIOUS BACKER UNITS: ANSI A118.9, NOMINAL 1/2" THICKNESS UNLESS OTHERWISE INDICATED OR REQUIRED F. STAIR SIGNAGE: PLASTIC WITH APPLIED COPY, VINYL LETTERS OR SILKSCREENED, AND BRAILLE. 6. RAILINGS: ' AINLESS STEEL TUBULAR RAILS ON THREE SIDES. FOR FIRE RATINGS; USG/DUROCK, NATIONAL GYPSUM/PERMABASE, OR CUSTOM BUILDING PRODUCTS/WONDERBOARD. G. BRAILLE EXIT SIGNS: PLASTIC. 7. PADS- •ROVIDE COMPLETE SET OF PADS TO PROTECT ELEVATOR FINISHES. H. CLEANING AND SEALING MATERIALS: AS RECOMMENDED BY TILE AND GROUT MANUFACTURERS, SUCH AS BOSTIK H. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE CODES AND REGULATIONS. H. IN id 'TION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, REFERENCED STANDARDS, AND APPLICA:. CODES CONSTRUCTION PRODUCTS/HYDROMENT CERAMASEAL. ' 0 REGULATIONS. I. PREPARATION: DO NOT COMMENCE WORK UNTIL CONDITIONS ARE WITHIN TOLERANCES REQUIRED FOR INSTALLATION; END OF SECTION . MAINTENANCE: STARTING AT DATE OF SUBSTANTIAL COMPLETION, PROVIDE 12 MONTH MAINTENANCE PROGRAM. APPLY LATEX LEVELING MATERIAL WHERE NECESSARY TO MEET REQUIRED TOLERANCES. SECTION 10500 - � J. WATERPROOFING: INSTALL WATERPROOFING AT TILE AREAS LOCATED ABOVE GRADE IN ACCORDANCE WITH A. GENERAL: PROVIDE METAL LOCKERS WITH ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. END OF SECTION MANUFACTURER'S RECOMMENDATIONS; EXTEND MEMBRANE MINIMUM 6" UP WALLS. B. MANUFACTURERS: LYON. K. CEMENTITIOUS BACKER UNITS: INSTALL UNITS IN ACCORDANCE WITH ANSI A108.11, MANUFACTURER C. TYPE: STANDARD TRIPLE TIER LOCKERS WITH FLAT TOPS AND "Z" TYPE RECESSED METAL BASES; PROVIDE TAMPER , RECOMMENDATIONS, AND AS REQUIRED TO PROVIDE FIRE RATINGS INDICATED ON DRAWINGS. PROOF HANDLES WITH BUILT-IN PADLOCK ATTACHMENT; STANDARD COLORS AS SELECTED. RIIA�N 1S � LREFER � IMP R L. TILE INSTALLATION: INSTALL TILE IN ACCORDANCE WITH REFERENCED ANSI STANDARDS AND TCA RECOMMENDATIONS (3 TIER 3 UNIT WIDE 5283-3 MODEL FOR TYPE OF SUBSTRATE AND INDICATED SETTING METHOD; LATEX-CEMENT THIN SET AND BOND COATS REQUIRED. MOD ( WIDE) 16 (REFER 1� 1. THIN SET APPLICATIONS: LATEX BOND COAT. 5283 (3 TIER 1 UNIT WIDE) 2. PLACE TILE IN ACCORDANCE WITH PATTERNS INDICATED ON DRAWINGS OR AS DIRECTED B Y ARCHITECT; CAREFULLY COLOR: DOVE GRAY D e n n i s Heath, A r c h i t e c t PLAN TILE LAYOUTS, ENSURE PATTERN IS UNINTERRUPTED FROM ONE SURFACE TO THE NEXT AND THROUGH D. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS. 2 4 1 0 M a r i n e r Square Loop DOORWAYS. 3. CLEAN AND SEAL TILE AND GROUT SURFACES WHERE RECOMMENDED BY MANUFACTURER FOR MATERIALS AND END OF SECTION A l a m e d a, C A 94501 APPLICATIONS INVOLVED; COMPLY WITH MANUFACTURER'S RECOMMENDATIONS. END OF SECTION SECTION 10810 - TOOT AIOCE"SSORIES A. GENERAL: PROVIDE TOILET ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. SEC110N 09510 - SUSPENDED ACOUSTICAL tELNNGS B. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PERSONS A. GENERAL: PROVIDE ACOUSTICAL CEILINGS INCLUDING SUSPENSION SYSTEM, TRIM, AND ACCESSORIES AS REQUIRED WITH DISABILITIES. D r e s i s g s a i d s r i t t a o m a t e r i a l a p p e a r i n g h e r e i n c o n s t i t u t e a r i g i a a l FOR COMPLETE FINISHED INSTALLATION. C. MANUFACTURERS: BOBRICK, BRADLEY, OR AMERICAN SPECIALTIES. old unpublished Tort of the Architect and rely not be duplicated, B. STANDARDS: CONFORM TO ASTM C635 FOR METAL SUSPENSION SYSTEM AND ASTM C636 FOR INSTALLATION OF D. TYPES: FLUSH MOUNTED TYPICAL FOR WALL MOUNTED UNITS; GRAB BARS AS REQUIRED BY APPLICABLE CODES AND u s e d or d i s c l o s e d w i t h o u t r r i t t e a c o n s e n t of t h e A r c h i t e c t ACOUSTICAL CEILINGS. REGULATIONS. ®D H ARCHITECTS- 2 0 10 C. MANUFACTURERS: ARMSTRONG; NO SUBSTITUTIONS. E. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE CODES AND REGULATIONS. D. SUSPENSION SYSTEM: ARMSTRONG/PRELUDE EXPOSED 15/16" T GRID SYSTEM, DIRECT HUNG, WHITE BAKED ENAMEL FINISHED STEEL OR ALUMINUM TYPE; EDGE TRIM WITH VERTICAL LEG CONCEALED. END OF SECTION Q A Q C E. ACOUSTICAL UNITS: ARMSTRONG/DUNE #1772, 2' BY 2' BY 5/8" PANELS. N o . D a t e I s s u e 1. FIRE RATINGS: PROVIDE SYSTEMS WITH FLAME SPREAD AND SMOKE DENSITY RATINGS OF 25/450 UNLESS OTHERWISE INDICATED. 05/28/10 100% SET F. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, REFERENCED STANDARDS, AND APPLICABLE 05/28/10 VT PACKAGE REQUIREMENTS FOR FIRE RATINGS. END OF SECTION 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET SECTION 09650 RESILIENT TILE FLAORNNG 08/13/10 PERMIT/BID SET A. GENERAL: PROVIDE RESIUENT TILE FLOORING SYSTEM AND RESILIENT BASE, WITH ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B. VCT FLOORING: ASTM F1066, COMPOSITION 1 (NONASBESTOS), 1/8" THICK VINYL COMPOSITION TILE, 12" BY 12". 1. MANUFACTURERS: ARMSTRONG, AZROCK, OR TARKETT. C. EDGE STRIPS AND ACCESSORIES: RUBBER OR VINYL EDGE STRIPS MATCHING RESILIENT FLOORING; LATEX-MODIFIED PORTLAND CEMENT BASED UNDERLAYMENT AND PATCHING COMPOUND; NONTOXIC WATER RESISTANT TYPE ADHESIVES. D. FLAMMABILITY: 0.45 WATTS/CM2 OR HIGHER, ASTM E648. E. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS; PREPARE SUBSTRATES IN ACCORDANCE WITH ASTM F710. END OF SECTION SECION 09657 - RESILIENT BASE A. GENERAL: PROVIDE RESILIENT BASE WITH ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B. MANUFACTURERS: ARMSTRONG, AZROCK, OR TARKETT. C. BASE: PROVIDE VINYL BASE WITH PREMOLDED CORNERS AND ENDS; COVE TYPE, 4" HIGH. D. ACCESSORIES: NONTOXIC WATER RESISTANT TYPE ADHESIVES. E. FLAMMABILITY: 0.45 WATTS/CM2 OR HIGHER, ASTM E648. F. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS; PREPARE SUBSTRATES IN ACCORDANCE WITH ASTM F710. END OF SECTION SECTION 09680 - CARPET A. GENERAL: INSTALL OWNER FURNISHED CARPET; PROVIDE ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. PROVIDE AT FITTING ROOMS AND ELEVATOR FLOOR. B. STANDARDS: COMPLY WITH CARPET AND RUG INSTITUTE (CRT) STANDARDS. Project N o. 44 122 C. CARPET: OWNER FURNISHED. D. EDGE STRIPS: BEVELED RESILIENT EDGING STRIPS; COMPLY WITH APPLICABLE CODES AND REGULATIONS. E. ADHESIVE: NON-TOXIC ADHESIVE AS RECOMMENDED B Y CARPET MANUFACTURER. S c a l e AS NOTED F. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND REFERENCED STANDARDS. END OF SECTION DrownBy: DM/AN E 0 m eL .o C:\Temp\AcPublish_3148\US220_SPECS.dwg K. Drawing No. 0 SPECIFICATIONS N - N a Q a O C 0 SP•O3 _. ., _O a. GENERAL NOTES DESIGN Design conforms to 2006 International Building Code. 0 0 7114A4 Design Live Load Roof 20 psf Retail 100 psf Catwalk Platform 40 psf Seismic Design Category (SDC) D - - Site Soil Class D Spectral Response Acceleration Data...Ss=0.948; Fa=1.12 2-3625162-54 PARTIAL 1 I - HEIGHT BUILT-UP BOX Dimensions refer to rough concrete surfaces, face of studs, face of concrete block, top of A COLUMN, SEE Allik sheathing, or top of slab, unless otherwise indicated. cj I S2.0 Typical Details and notes on these sheets shall apply unless specifically shown or noted US220 otherwise. Construction details not fully shown or noted shall be similar to details for similar WASHINGTON SQUARE conditions. All work and construction shall comply with all applicable building codes, regulations, and safety requirements. • 9585 S.W. Washington Square IP 000S162-54 BUILT-UP 4 SUITE H08 Discrepancies: The Contractor shall inform the Architect in writing, during the bidding period, BOX BEAMS, SEE DETAIL of any discrepancies or omissions noted on the drawings or in the specifications, or of any '12005162-54 BUILT-UP 4 S2.0 PORTLAND, OR 97223 variations needed in order to conform to codes, rules, and regulations. Upon receipt of such BOX BEAM, SEE DETAIL S2.0 information, the Architect will send written instructions to all concerned. Any such CLASS: RED discrepancy, omission, or variation not reported shall be the responsibility of the Contractor, and work shall be performed in a manner as directed by the Architect. -I - - - 38 - - - -Di- - - - 38 Shoring: It shall be the Contractor's sole responsibility to design and provide adequate shoring, bracing, and formwork, etc., as required to hold the various elements in place until final support is securely anchored, and for the protection of life and property during the construction of this building. 2 S2.0 I Other Trades: See architectural, electrical, and mechanical drawings for size and location of pipe, vent, duct and other openings, and details not shown on these structural drawings. All dimensions are to be checked and verified with the architectural drawings. Welding shall be performed by welders certified for the welds to be made. © �1,J r 719----{ 0 •G� PR'.3 \ Shop Drawings shall be submitted to Architect for review, where noted. Engineer will review 1 �, �j� reproducible copy and 2 prints. ``.., ../ i ir EXISTING CONSTRUCTION ( 2-3625162-54 FULL 2-3625162-54 PARTIAL , ��, EDGE OF SLAB HEIGHT BUILT-UP BOX COLUMN, SEE BUILT-UP BOX -n 9� i q`' Existing construction shown on the drawings was obtained from field surveys by others. The VERIFY IN FIELD COLUMN, SEE 3 © '�C'y 14 �°' SO Contractor shall verify all existing conditions and shall notify the Architect of all exceptions '� 52.0 52.0 �"� ,t�� before proceeding with the work. I R© - Ex p. 12/31/2010 The removal, cutting, drilling, etc. of existing work shall be performed with great care and 12005162-97 BUILT-UP 4 12005162-97 BUILT-UP 4 P small tools in order not to jeopardize the structural integrity of the building. If structural BOX BEAM, SEE DETAIL S2.0 BOX BEAM, SEE DETAIL S2.0 members, not indicated for removal, interfere with the new work, the Structural Engineer shall "a be notified immediately and approval obtained before removal of the existing members. m The Contractor shall safely shore existing construction wherever existing supports are removed to allow installation of the new work. The existing construction shall be connected and/or C° •� Q embedded into the new construction as shown or specified. S2.0 ♦ - • LIGHT STEEL STRUCTURAL FRAMING I I HSS 2x2x1/4" SUPPORT FRAME Light gauge steel members shall be the types indicated on the drawings, as manufactured by TYP OF 4, SEE iik 1 BOX WALL a member of Steel Stud Manufacturer's Association, under ICC ER-4943P. Other suppliers BY OTHERS NOTE: S2.0 S2.0 having current ICC Research Reports, with properties of steel members equal to or greater 600 LBS MAX 1. FOR COLUMN CONN. TO (E) Structural Engineers than those in ICC ER-4943P, may be used with prior written approval from the Structural CONCRETE SLAB SEE . Engineer. Material for steel members, including special shapes, angles, etc. shall have S2.0 Robinson 103 Linden Avenue minimum Fy = 33,000 psi for 43 mils (18 gauge) and lighter and Fy = 50,000 psi for 54 Meier So.San Francisco,CA 94080 mils (16 gauge) and greater. Members may be galvanized (G60 coating) or shop painted. - 2. FOR BUILT-UP STUD AND 4 Juilly&Associates Tel: 650.871.2282 See TRACK SIZES PLEASE SEE DETAIL ® ' S2.0 • www.rmjse.com Fax: 650.871.2459 s1.0 RMJ Job No.: 10164 FASTENERS Sheet Metal Screws (S.M.S.) - See 0 s 1.0 #10 - Wafer Head. Use Hex Washer Head only where architectural finish will allow it. 6" MAX Drawings and fritters material appearing herein constitute original Low Velocity Drive Pins and unpublished fork of the Architect and may not be duplicated, Hilti X-DNI fasteners, types as indicated per ICC ESR-1663 or by manufacturer having u s e d or d i s c l o s e d f i t h o u t w r i t t e n c o n s e n t of t h e A r c h i t e c t current ICC Reserch Report with values (in shear and tension) equal or greater. I I @0 H ARCHITECTS - 2010 `" 2-3625162-54 FULL 2-3625162-54 PARTIAL Wedge Anchors HEIGHT BUILT-UP BOX HEIGHT BUILT-UP BOX Hilti Kwik Bolt TZ Concrete Anchor, types as indicated per ICC ESR-1917 or by I COLUMN, SEE Apik COLUMN, SEE AI QM Q C manufacturer having current ICC Research Report with values (in shear and tension) equal or , I I a S2.0 S2.0 N a • D a t e I s s u e greater. BOX WALL SUPPORT ED) 05/28/10 100% SET st3/4" MIN. 3/4" MIN.'r , 1/4"=1'-0" 2. © 05/28/10 VT PACKAGE ________1L gm`i ( �,�����V' HEIGHT BUILT-UP BOX 07/02/10 100% COMPLETE SET 2-3625162-54 PARTIAL COLUMN, SEE Ali 07/28/10 LANDLORD SET #10 S.M.S. HEX #10 S.M.S. I I S2.0 08/13/10 PERMIT/BID SET WASHER HEAD WAFER HEAD SHEET METAL I I S CREWS ( s . M . S . S20 1 NO SCALE S1.0 12005162-54 BUILT-UP 4 BOX BEAM, SEE DETAIL S2.0 I I 1. Refer to SSMA (Steel Stud Manufacturers Association) ("Production Technical Information" Catalogue, and ICC ER-4943P. www.ssma.com . ISSUE LOG 1000s162-54 BUILT-UP (www.ssma.com). C �" BOX BEAMS, SEE DETAIL 4 C \ 9 _ x 2. 3625200-54 Is A 3 5/8" Deep By 2" Flange C-STUD and the _ _ 52.0 Material Thickness is 54 MILS. = 3. S = Stud or Joist Sections, CEE Shape:C Lid T = Track Sections . C4 U = Channel Sections i Cb F = Furring Channel Sections 0 I-.. 2-3625162-54 PARTIAL 4. MIN. THICKNESS (MILS) GAUGE NO. No. SHEET NAME �� .;.s p HEIGHT COLUMN BUILT-UP SEE BOX 0 , �.. ,` / S2.0 18 25 Project No . 44122 27 22 GENERAL NOTES STOREFRONT FOUNDATION A -■ 30 20 - DRY WALL S1.0 PLAN AND SOFFIT FRAMING PLAN 1 33 20 - STRUCTURAL S2.0 STOREFRONT SECTIONS AND DETAILS - _ _ _ E - _ - -'0 - - - 36 S c a I e AS NOTED - - 36 43 18 - - 54 16 c-D o c) I DrownBy; DM/AN 68 14 ISSUE LOG KEY: w 97 12 `�"' ISSUED AS PART OF A SET Q t- N , "*" ISSUED AS PART OF A SET w/o i,j i j M:\2010jobs\10164 (H&M Washington Squore)\10164_S1.O.dwg Q CHANGES o 0 0 o Drawing No . N N STEEL STUD NOTES C-0 GENERAL NOTES s,a NO SCALE PARTIAL SOFFIT FRAMING PLAN 2 PARTIAL FOUNDATION PLAN 1 1/4"=1'-0" S2.0 1/4"=1'-0" S2.0 Sin . <,111.0>> :11(:11/111111/ 1111! 362S126-33 DIAG. BRACE at 4'-0" at TOP OF 6" VERT. . STUD FOR ATTACHMENT TO (E) 8 TWO CONT. STUDS ROOF STRUCTURE SEE DETAIL ° S2.0 w/ CONT. TRACK 0 --1 T&B, SEE PLAN ,40.0 -(E) MALL BULKHEAD. ° •/ SHOWN HATCHED 0 ° COLUMN,BUILTS-EUP aa , ---1 r--- 6005162-54 STUD- ---- _ / 1 S2.0 li at 16" o.c. / A 0 0 . 44101/1°11°H °. (E) STEEL OWSJ /- /. • 0 • . / -wL2/xii2ix020s.GmA.s. . _(2 #pi.oss..Em.sEAscHHowsE , .// BSTuOLPT_TuRpACcK0SLuOmFN 41111L- 16-#10 S.M.S. AT POINT OF I < Us220 7., LOAD(S) OR REACTION(S), 1----,\--- EA FLANGE SHORT OF BOTTOM -, D,r „i). EA STUD TRACK TYP. AT BUILT-UP BEAM (8 ...„...K,-- SCREWS ON THE TWO OPP. WASHINGTON SQUARE 362S126-33 DIAG. STUD at 4'-0" o.c ATTACH TO (E) ,-„-1. ------ ° * t 11 9585 S.W. Washington Square HSS TUBE FOR ATTACHMENT : : 0 --1 ' • • (0:11 il , SUITE H08 SEE DETAI(_ink i " dP kr 1 6. > il il ' 1161111111111111, PORTLAND, OR 97223 IIII 8-#10 S.M.S. at 12"o.c., TYP. CLASS: RED _.---/ Ard-tNN 0 0 cv 362T150-33 TRACK w/ H ; II , Ar AT BUILT-UP BEAM (4 SCREWS I (E) HSS__, USE 24;0 SIMPSON TITEN 3-HILTI 0.145" DIA. ON THE TWO OPP. FACES NOT ____JEL_____ Pri \N , 6x6x1/4, V.I.F. x \ HD CONCRETE SCREWS at FASTENERS TO CONC. SHOWN) NN4v, / :UILT-UP METAL STUD FULL HEIGHT COLUMNS IN COPE FLANGES EA. END. omommonowim■mmmi 0 . . rD : : •.\ CD • P -I : * BOX BEAM SEE PLAN LIEU OF POWDER DRIVEN WEB PROTRUDES 21/2 3/80 THRU \ PINS (EMBED 21/21) EA. END TYPICAL BUILT-UP BEAM BOLT EA 0 N - 1 ,. ..., , 1 \\ END, TYP. BUILT-UP METAL- N \ i I N , 0 ', ,i 0 T.O. DISPLAY WNDOW IV ISOMETRIC l ISOMETRIC 6 ISOMETRIC g Li_ ,All („) 0 L. -----------------4.L \ \ / STUD BOX I - -.. ' L _1 1-1/2" = 1'-o" S2.0 N.T.S. S2.0 N.T.S. S2.0 . \ 9....._ BEAM SEE PLAN - --:- .- 1-. - \ \---- , --;_--.---_ *rf-- ----im-:-. 0 t ) , .,• , . . - N CD I . 1 't P'/Piik 0 - _I- - -.IL- i__J L._1____' TRIM STUD TO FIT-----,c,- L kilit.itk,•... INTO 35/8 TRACK ___)e-- \\. 1 1 2x2x20 GA. OW) 1 S.M.S. EA FLANGE EA 1 /51 CONT. 362T150-33 ,LA STUD 1 R G II N BOTTOM TRACK w/ #10 FINISH 16GA.x4"x4"x0'-6" LONG 1._.41, S.A.D. BENT PLATE at 4'-0"o.c. -1-0/ 14 FLANGE w/4-0.145"0 P.D.P. TO e,P ANGLE AND 4-#10 S.M.S. TO DIAG. BRACE Exp. 12/31/2010 DIAG. BRACE 3/4”Ø BOLT IN L5x3x1/4 L.L.V PIECE OF 362T150-33 Emil 1 at 4'-0"o.c. VERT. SLOT HOLE EA. SIDE TRACK AT TOP OF PARTIAL FOR BUILT-UP A,,.. HEIGHT POST, TYP. w/ 2 I . • S COLUMN, SEE Ma -#10 S.M.S. EA SIDE. wwowsmmoou000mo■omomi S2.0 MI * • ' 1 1 I , I 7 BUILT-UP BEAM w/ 4"x4"x0'-35/8" LONG x16 45 2-362T150-33 ° •0 GA. ANGLE WITH 4-#10 .. TRACKS, SEE PLAN FOR ° ° S.M.S. TO BM. AND 4-#10 (E) HSS6x6x1/4 ----) FOR CONNECTION STUD SIZES S.M.S. TO COLUMN SECTION 1 STUDS FOR BUILT-UP '. * . 0 BELOW, SEE AI 'c lek TYP.> 3/ > ../ Structural Engineers Robinson 103 Linden Avenue 3/4"=1:-0" S2.0 BEAMS SHALL HAVE . 16GA.x4"x4"x0'-6" LONG S2.0 S2.0 /16 BENT PLATE at 41-0"o.c. Meier So.San Francisco,CA 94080 %" WIDE FLANGES, " "x 16 A PLATE WITH 1TYPICAL lik:..7):!",07 ------ 44410 S.M.S. TO BEAM w/4-0.145"0 P.D.P. TO OR Juilly&Associates Tel: 650.871.2282 CI 1 ° AND 4-#10 S.M.S. TO COLUMN, EACH SIDE , ANGLE AND 4-#1 0 S.M.S. TO DIAG. BRACE ,,,, NOTE: IL.' CONTRACTOR MAY , k , , www.rmjse.com Fax: 650.871.2459 , 0 al ° a I 0 0 1 (OPPOSITE SIDE NOT SHOWN FOR CLARITY) IIP'2" CHOOSE WELDED OR , , i , RMJ Job No.: 10164 PIN CONNECTION I N., ° DIAG. BRACE 1 'h ,,:-- / r-----11r3 at 4'-0"o.c. BOTH SHOWN. ,,,,,, 1% „,_ , 3625126-33 DIAG. BRACE at ..,. ":„...1%0 ..- woomommoommliw / 1,,,. " .....__________„------- 4"x4"x0'-35/8" LONG x16 I -"Ir-- --- HSS 2x2x1/4 4'-0" at TOP OF 6" VERT. D r a w i n g s and w r i t t e n m a t e r i a l a p p e a r i n g herein constitute original GA. ANGLE WITH 4-#10 L jillsibl 6i and unpublished work of the Architect and may not be duplicated, STUD FOR ATTACHMENT TO (E) a ° ° S.M.S. TO BM. AND ROOF STRUCTURE SEE DETAIL ° •0 0 used or disclosed without written consent of the Architect S2.0 (1.° 4-#10 S.M.S. TO COLUMN ) ®DH ARCHITECTS - 2010 I 6005162-54 STUD ' Is 4 at 16" o.c. 101 Pre // at 8"o.c. (E) HSS6x6x 1/4 -----Yi FOR CONNECTION BELOW, SEE QAQC EA. LEG EA. TRACK AI 84 A% No . Date Issue S2.0 S2.0 05/28/10 100% SET (E) MALL BU LK H EAD. ISOMETRIC 4 DETAIL 7 DETAIL EIO'\ 05/28/i 0 VT PACKAGE SHOWN HATCHED 1-1/2" . r-o" S4.0 1-1/2"=V-0" S2.(y o7/ovio 100% COMPLETE SET 07/28/10 LANDLORD SET L2x2x20 GA. w/#10 cip r.„.1.11s.m.s. EA FLANGE EA 08/1 3/10 PERMIT/BID SET STUD 3625126-33 DIAG. STUD at 4'-0" o.c. ATTACH TO (E) ■ 14'-0" A.F.F. (V.I.F.)61 HSS TUBE FOR ATTACHMENT SEE DETAIL alti • • . . T.O. STOREFRONT IV S2.0 COLUMN HEIGHT STUDS TRACKS T-T (E) HSS 6x6x1/4, V.I.F. 41 ,?-------- ----'""BUILT-UP METAL STUD 15' MAX. (PARTIAL) 2-362S162-33 2-362T150-33 IreP'< Ilk Luigi BOX BEAM SEE PLAN ,_ AL, \ rr \ 0 0 1 .-* .--**-----HSS 2x2x 1/4 #\\ 41 > 2-STUDS WITH TRACK - _,.... _ ____ • • • o • - T 7 \- -. . o c_=:) ' -#P 1.-- EACH SIDE, TYPICAL AT . . --: .*-, 0 0 6005162-54 STUD--,, :- - _ at 16" o.c. Ni- T a 0 BUILT-UP COLUMN, TT 111")4 12'-0" A.F.F. SEE TABLE.F. di BENT PL 16GA. P5501 UNI-STRUT, • .. . 0 K T.O. DISPLAY WN DOW IV w/ 4 -#12 TEKS SEE 9 4 -#12 TEKS SCREWS ,. . • . . SCREWS TO UM-STRUT TO UNI-STRUT (E) CONC. . FINISH S2.0 S.A.D. ,--i----., SLAB -----) ------L4x4x 5/1,x4" 3 • ,- .._ ._.., .._ J ......., > 7,--- 16-#10 S.M.S. AT POINT r-r-rir 1 4.44r-1 LONG w/3/4"0 IllirrilIW z - . . IP II. OF LOAD(S) OR I • F--' EXPANSION 0 REACTION(S), TYPICAL AT - BOLT EMBED 3 =_. . .._ - , , • il, J / 41111 ,. a , BUILT-UP COLUMN (8 / ....,-,,-. L2x2x20 GA: _.,-.}6' 11 0 -1 1 - rt '-' __. , % , % , -' , --- - , --- , --- 1 % 0 0 SCREWS ON THE TWO OPP. FACES NOT SHOWN) / DIAG. BRACE at (E) STEEL-- --_,.... 1/ V /4" Project No . 44122 w/#10 S.M.S. H I 0 llr'‘„' -' L --- -.. 1 4'-0"o.c. BEAM EA FLANGE H _LJ I Ni I 11 '1' ',J __i r: WALL BOX S c a l e AS NOTED EA STUD -,--- --- I I j,. .- ,-_, ,--- 7 ------- 8-#10 S.M.S. at 12"o.c., BRACE PARALLEL TO BRACE PERPENDICULAR \ 7"r,,,' -3------ --- 1 ___, DrawnBy: DM/AN ____,\,..7 If li ,il , --' TYPICAL AT BUILT-UP (E) BAR JOISTS TO (E) BAR JOISTS 1/ 7 II III /4I II III LV ,,, ° a 0 COLUMN (4 SCREWS ON I 0 ii___ ,.1f-. ,-- . THE TWO OPP. FACES NOT L3x3x1/4 ° if- IA ...zi,,-- " ,._, SHOWN) EA. SIDE E y II HSS 2x2x1A m:vot ojobsv 0164 (H&M Washington SguareA10164_S2.0.dwg OUTRIGGER POWDER DRIVEN ANCHORS at- POWDER DRIVEN ANCHORS at 16" o.c. (TYP.) 16" o.c. (TYP.) - Drawing No . - R, ,i SECTION THRU DISPLAY WINDOW TYPICAL BUILT-UP COLUMN STOREFRONT -4, SECTIONS SECTION C-0 ISOMETRIC 5 DETAIL (i) DETAIL Cif) & DETAILS . -0 E N.T.S. S2.0 .1-112"=V-0" S2.0 1-1/2"=V-0" S2.0 3/4"=1:-0" S2.0 -,E , . 15 S2 .0 + . ELECTRICAL GENERAL DOTES LIGHTING FIXTURE SCHEDULE NOTES ELECTRICAL SYMBOLS ALL SYMBOLS DO NOT NECESSARILY APPLY 1. FINAL CONNECTIONS TO ALL LAY-IN FIXTURES AND RECESSED 2010 LIGHTING FIXTURE SCHEDULE ULE (277V) 1. FOLLOWING LIGHT FIXTURES, INCLUDING LAMPS,ARE TO BE FURNISHED BY H 8 M AND INSTALLED BY ELECTRICAL CONTRACTOR: MOUNTING HGT. TO CENTERLINE INCANDESCENT FIXTURES IN LAY-IN CEILINGS ARE TO BE MADE WITH LOAD No.OF a.APPROXIMATE a °A" SYMBOL DESCRIPTION UNLESS OTHERWISE NOTED GREENFIELD FLEXIBLE CONDUIT. TYPE LAMP TYPE MANUFACTURER CATALOG NUMBER DESCRIPTION CATALOG FIXTURE (VA) LAMPS NUMBER COUNT b. 'D" 0 CEILING OUTLET c. "D3" 2. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION 8"RECESSED 35W METAL HALIDE d. "F" -0 WALL OUTLET SEE DRAWINGS OF LIGHT FIXTURE LAY-OUT. CONTRACTORS TO CORRELATE LOCATIONS OF APEX 35E: FLOOD DOWNLIGHT WITH ANODIZED e. "G" 0 SPECIAL OUTLET, AS REQUIRED SEE DRAWINGS LIGHTING,SPEAKERS,AIR DIFFUSERS,GRILLES,AND THE LIKE,WITH Q4 A 44 I CDM3ITEM #: 91206 TRIMLESS CYLINDRICAL TRIMLESS f :L1: REFLECTED CEILING LAY-OUTS AS REQUIRED AND DIRECTED BY THE 5/T6/N30 NORDIC LIGHT REFLECTOR AND CLEAR GLASS 91206 2Z4 0 WIRED JUNCTION BOX SEE DRAIMNGN ACCESSORIES: 1951 °LENS. I20-277VAC. SEE ARCHITECT. LIGHTING FIXTURE SCHEDULE h. L3" © BLANK OUTLET BOX SEE DRAWINGS NOTES I AND 4 i. °L4" DUPLEX RECEPTACLE, 3 WIRE GRD. TYPE 18" 3. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND/OR ROOM FINISH SQUARE SINGLE LAMP RECESSED �' SCHEDULE TO DETERMINE PROPER TYPE OF LIGHT FIXTURE REQUIRED FOR T k. "LIGHTING TRACK" d DUPLEX RECEPTACLE, FLOOR MOUNTED : THE CEILING CONSTRUCTION PRIOR TO ORDERING THE FIXTURES AND SHALL ITEM ITE I#:MEDIUM 77606M S PREAD 20W METAL HALIDE DOWNLIGHT BLACK "LI O4 B 26 ! CDM20/T6l830 NORDIC LIGHT WITH ANODIZED CYLINDRICAL �WP DUPLEX RECEPTACLE, WEATHERPROOF 18" PROVIDE FIXTURES THAT ARE COMPATIBLE WITH THE CEILING SYSTEM. US220 REFLECTOR, CLEAR GLASS LENS, 77606M 44 ACCESSORIES: 1951 AND BLACK TRIM. 120-277VAC. 2. VERIFY INSTALLATION LOCATION OF ALL MONOPOINT TRACK LIGHTING GFI GROUND FAULT PROTECTED DUPLEX RECEPTACLE 18" SEE LIGHTING FIXTURE FIXTURES WITH H& M CONSTRUCTION MANAGER IN FIELD. ELECTRICAL 4 ISOLATED GROUND DUPLEX RECEPTACLE 18" 4. ALL DEVICES, EQUIPMENT,FIXTURES,AND THE LIKE,MUST BE GROUNDED BY WASHINGTON SQUARE SCHEDULE NOTES I AND 4 CONTRACTOR IS TO INCLUDE IN BID THE COST TO INSTALL " USE OF A PROPERLY SIZED GROUNDING CONDUCTOR. QUADRAPLEX DUPLEX RECEPTACLE 18 APPROXIMATELY 375 MONOPOINT TRACK LIGHTING FIXTURES. M9HD-EflS-LOOM 9"RECESSED (2) 100W METAL MECHANICAL/ELECTRICAL BONDS OF THE METALLIC RACEWAY SYSTEM M952LC-8-PG HALIDE DOWNLIGHT WITH WHITE ISOLATED GROUND QUADRAPLEX DUPLEX RECEPTACLE 18* 9585 S.W. Washington Square SHALL ALSO BE MAINTAINED. D3 125 I MHCI00/C/UIM/3K/ALTO SPECIALTY LIGHTING ITEM #: 911045 BLACK REFLECTOR, CLEAR GLASS LENS, 911045 24 Q/ DOOR BUZZER AS REQUIRED SUITE H08 AND BLACK TRIM RING. 277VAC. 3. FOLLOWING LIGHT FIXTURES, INCLUDING LAMPS,ARE TO BE ACCESSORIES: 1951 NOTE I FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR TO LINE VOLTAGE THERMOSTAT 60" 5. REFER TO MECHANICAL PLANS FOR EXACT LOCATION OF MECHANICAL PORTLAND, OR 97223 TUBE MINI-35E: SPOT 35W BLACK METAL HALIDE TRACK (ACCEPTABLE EQUALS ARE LISTED): 44 TOGGLE SWITCH - KEY OPERATED 48" EQUIPMENT AND LOCATE DISCONNECT SWITCHES IN ACCORDANCE WITH OF 44 I CDM35/T6l830 NORDIC LIGHT HEAD. SEE LIGHTING FIXTURE 77592 102 a. "M"series: LITHONIA, METALUX P THE NEC. CLASS: RED ITEM #: 77592 BLACK SCHEDULE NOTES I & 2 b. "N" series: LITHONIA, METALUX 4'+ TOGGLE SWITCH - W/ PILOT LIGHT 48" TUBE MINI-35E: SPOT 35W WHITE METAL HALIDE TRACK C. "EX1":SURE-CITES, EMERGI-LITE 44 TOGGLE SWITCH - SINGLE. 3-WAY & 4-WAY 48" 6. REFER TO DIVAS SPECIFICATIONS, HVAC PLANS AND PLUMBING PLANS FOR O G 44 I CDM35/T6/830 NORDIC LIGHT HEAD. SEE LIGHTING FIXTURE 77597 238 d. “EX2": SURE-LiTES, EMERGI-CITE --4,- MANUAL MOTOR STARTING SWITCH W/ PILOT LIGHT 48" ADDITIONAL ELECTRICAL WORK AND REQUIREMENTS. ITEM#: 77597 WHITE SCHEDULE NOTES I & 2 e. "EM": SURE-CITES, EMERGI-CITE 23"FLUORESCENT STRIP LIGHT N DATA OUTLET 18" ,� COMPLETE WITH A NECESSARY 5 (D) COMMUNICATIONS OUTLET MOUNTED AT 18" U.N.O. PROVIDE 7. ALL RECEPTICLES SHOWN BACK-TO-BACK IN WALLS SHALL BE SEPARATED BY :: ' LI 16 1 FI4T5/830/ALTO HERA LIGHTING ES22 CONNECTING ACCESSORIES. SEE N/A 25 4. ALL SHADED LIGHT FIXTURES LABELED WITH "NL"ARE FIXTURES THAT CONDUIT SIZED PER SPECIFICATIONS' FILL REQUIREMENTS 8" MINIMUM. ��// LIGHTING FIXTURE SCHEDULE (3/4" MINIMUM) TO DATA RACK IN "LAN ROOM" WITH NOTE I ARE TO BE ON CONTINUOUSLY (24 HOURS,7-DAYS A WEEK). CABLING PER SPECIFICATIONS. "W ADJACENT TO SYMBOL INDICATES WALL MOUNTED AT 54" A.F.F.. REFER TO 8. WIRING IN PLENUMS SHALL BE PLENUM RATED OR INSTALLED IN CONDUIT. RESPONSIBILITY SCHEDULE IN SPECIFICATION SECTION 16740. 35"FLUORESCENT STRIP LIGHT D - DATA COMPLETE WITH A NECESSARY NUMBER ADJACENT TO SYMBOL DEFIES THE QUANTITY OF CABLES 9• BRANCH CIRCUIT WIRE SIZES (AND CONDUITS)SHALL BE INCREASED FROM 3 L2 24 I F2IT5/830/ALTO HERA LIGHTING ES34 CONNECTING ACCESSORIES. SEE N/A 19 THOSE INDICATED ON THE PLANS TO PREVENT EXCESSIVE VOLTAGE DROP. LIGHTING FIXTURE SCHEDULE BRANCH CIRCUITS SHALL BE INSTALLED WITH WIRES OF SUFFICIENT SIZE SO NOTE 1 • ELECTRIC PANEL 6'-0" TO TOP THAT VOLTAGE DROP BETWEEN THE PANEL AND THE LOADS DOES NOT • I !-1 SAFETY SWITCH AS REQUIRED EXCEED A LIMIT OF 3%. MAGNETIC MOTOR STARTER AS REQUIRED 7"." 47"FLUORESCENT STRIP LIGHT 10. WIRE SIZES SHALL BE BASED ON THE t,0°C.AMPACITIES FOR WIRE SIZES NO. r �{ , COMPLETE WITH A NECESSARY COMBINATION STARTER/SAFETY SWITCH AS REQUIRED �� --' , 3 L3 30 I F28T5/830/ALTO HERA LIGHTING ES46 CONNECTING ACCESSORIES. SEE N/A 207 �,(� 14-1 AWG,AND 752C.AMPACITIES FOR WIRE SIZES#1/0 AWG AND LARGER. F LIGHTING FIXTURE SCHEDULE 7 `-' CLOCK 96" iVtqe049 i NOTE I U PUSHBUTTON STATION 48" 11. CIRCUITS MAY BE MULTI-PLEXED IN CONDUIT PROVIDED WIRE IS PROPERLY `� ,I\ , i a START/STOP PUSHBUTTON STATION 48" DERATED AND CONDUIT SIZED PER CODE. UNDER NO CIRCUMSTANCES ":1 13"FLUORESCENT STRIP LIGHT MOTOR OUTLET - 1 PHASE AS REQUIRED SHALL MORE THAN NINE(9) CURRENT CARRYING CONDUCTORS BE RUN IN A �°' ,w ^i r,. ' 3 LUORESCE T STR LIG T � .� M,.�'"" COMPLETE WITH A NECESSARY SINGLE CONDUIT. - <- OL4 16 I F8T5/830/ALTO HERA LIGHTING ESI2 CONNECTING ACCESSORIES. SEE N/A I t MOTOR OUTLET - 3 PHASE AS REQUIRED LIGHTING FIXTURE SCHEDULE Q FIRE ALARM BREAK STATION 48" 12. ALL CONDUITS SHALL CONTAIN A GROUND WIRE SIZED PER NEC TABLE#250- NOTE I LOCATION OF NAMEPLATE FOR SURFACE F[] 1 FIRE ALARM AUDIOVISUAL SIGNAL DEVICE 96" 122. IN ADDITION,WHERE AN ISOLATED,INSULATED GROUND IS REQUIRED, 2`x4' LAY-IN RECESSED MOUNTED PANELS. LOCATE NAMEPLATE D WALL BOX - DIMMER 48" A SEPARATE GREEN GROUND SHALL BE RUN FROM THE PANEL. GROUND FLUORESCENT FIXTURE WITH BEH I ND DOOR ON RECESSED PANELS. BUS TO THE ISOLATED GROUND CONNECTION OF THE DEVICE. IN NO CASE .125"ACRYLIC PRISMATIC LENS, II ■'4 (PAGING/MUSIIC/SECUURITY) SHALL THE SYSTEM GROUND(WIRE AND ASSOCIATED OUTLET BOXES, MI 90 3 F32T8/830/ALTO DAY-BRITE 2TG8332-21-UNV-I/2-EBI01 FLAT STEEL DOOR AND N/A 26 ENGRAVED PHELNO 1 C PLATE WI TH WALL MOUNTED SPEAKER SEE DRAWINGS CONDUIT AND BUILDING STEEL)BE ALLOWED TO CONTACT THE ISOLATED ELECTRONIC BALLAST, 277 VAC. BLACK FACE AND WH I TE LETTERS. "" GROUND(GREEN WIRE AND DEVICE). WHERE CIRCUIT CONDUCTORS ARE SEE LIGHTING FIXTURE SCHEDULE NOTES 3 AND 4 ENGRAVED LETTERS ARE TO BE 5/32" •I• MICROPHONE OUTLET, FLOOR MOUNTED INCREASED IN SIZE FOR VOLTAGE DROP,THE GROUND WIRE SIZE SHALL BE H B K 2'x4' FLANGED RECESSED PANEL HIGH• FASTEN NAMEPLATE TO PANEL 9 MICROPHONE OUTLET, WALL MOUNTED SEE DRAWINGS INCREASED PROPORTIONALTELY(ACCORDING TO CIRCULAR MIL AREA) ""' '`� WITH ADHESIVE TYPE FASTENERS. FROM THE SIZE REQUIRED BY NEC TABLE#250-122. FLUORESCENT FIXTURE WITH ® ® VOLUME CONTROL - P.A. SYSTEM 48" .125"ACRYLIC PRISMATIC LENS, RI T.V. OUTLET 24" CONSiULTAN'TS LTD M3 90 3 F32T8/830/ALTO DAY-BRITE 2TG8332-21-UNV-I/2-EB101 FLAT STEEL DOOR AND N/A 6 3" ELECTRONIC BALLAST, 277 VAC. --.4 EMERGENCY CALL PULL STATION 24" Mechanical & Design Services SEE LIGHTING FIXTURE SCHEDULE NOTES 3 AND 4 EQU I PMENT DES I GNAT I ON W/REMOTE INDICATORS DETECTOR AS REQUIRED 2'x2'LAY-IN RECESSED 171 Charring Cross Drive S. FLUORESCENT FIXTURE WITH 0 FIRE ALARM WATER FLOW SWITCH AS REQUIRED Suite 1B .125"ACRYLIC PRISMATIC LENS, © Westerville, Ohio 43081 FIRE ALARM TAMPER SWITCH AS REQUIRED ,882.1199 N2 55 2 F32T8/U/830/ALTO DAY-BRITE 2TG8231U6R-21-UNV-I/2-EBIOI FLAT STEEL DOOR AND N/A 6 FAX 614 14 814,882,1857 1199 ELECTRONIC BALLAST, 277 VAC. 0 SYSTEM SMOKE DETECTOR CEILING MTD. SEE LIGHTING FIXTURE NOTE: -®H - SYSTEM PHOTO/HEAT DETECTOR CEILING MTD. SCHEDULE NOTES 3 AND 4 NAMEPLATES ARE REQUIRED ON ALL SWITCHBOARDS, DISTRIBUTION PANELS, �, LIGHTING GENERAL NOTES 2`x2' FLANGED RECESSED PANELBOARDS, DISCONNECT SWITCHES, RELAYS AND JUNCTION BOXES LARGER H SYSTEM HEAT DETECTOR (FIXED TEMP.) CEILING MTD. FLUORESCENT FIXTURE WITH THAN 4 11/16" SQUARE. ALSO PROVIDE NAMEPLATES ON BRANCH SWITCHES OF LJ" FIRE ALARM AUDIO/VISUAL UNIT 90" 125"ACRYLIC PRISMATIC LENS, SWITCHBOARDS AND DISTRIBUT ION PANELS. 1. REFER TO DRAWING E4.4 AND E4.5 FOR SCHEDULES AND Drarings and written material appearing herein constitute original N4 55 2 F32T8/U/830/ALTO DAY-BRITE 2TG8231U6R-2I-UNV-I/2-EB10I FLAT STEEL DOOR AND N/A I F[ - FIRE ALARM VISUAL UNIT 90" DETAILS OF THE LIGHTING CIRCUITS CONTROLLED BY THE a n d u n p u b l i s h e d r o r k of t h e A r c h i t e c t a n d may n o t be d u p l i c a t e d, ELECTRONIC BALLAST, 277 VAC. 0 ELECTRIC DOOR LOCK CONNECTED TO F.A. SYSTEM AS REQUIRED LIGHT-STAT LIGHTING CONTROL SYSTEM. u s e d or d i s c l o s e d w i t h o u t w r i t t e n c o n s e n t of t h e A r c h i t e c t SEE LIGHTING FIXTURE STANDARD COLORS: SCHEDULE NOTES 3 AND 4 MAGNETIC DOOR HOLDER CONTROLLED c h1 B H ARCHITECT - 2 0 1 0 4 1 . NORMAL POWER - BLACK BACKGROUND WITH WHITE LETTERS. VIA FIRE ALARM SYSTEM AS REQUIRED 2. ALL"A"TYPE NIGHT LIGHTS (NL)SHALL BE WIRED THRU THE 35W WHITE METAL HALIDE TRACK 2. EMERGENCY POWER - RED BACKGROUND WI TH WH I TE LETTERS. R 78 I CDM70/T6/830 NORDIC LIGHT TUBE MINI 70E: SPOT HEAD. SEE LIGHTING FIXTURE 77582FLAP 12 3. ALL MAIN SERVICE DISCONNECTS - RED BACKGROUND WITH WHITE LETTERS. m NIGHT WATCHMEN SYSTEM STATION 48» LIGHT-STAT LIGHTING CONTROL SYSTEM AND BE SCHEDULED ITEM#: 77582FLAP WHITE "� " ()A 0 C SCHEDULE NOTES 1 & 2 HALON PULL STATION 54" TO TURN«OFF FOR A DURATION OF HALF AN HOUR AND THAN L.E.D. EDGE-LIT EXIT SIGN WITH TURNED"ON"SO AS TO CYCLE OFF THE METAL HALIDE LAMPS. N a. D a t e I s s u e HALON IONIAZTION DETECTOR SUB FLOOR CYCLING OF LAMPS IS TO BE SCHEDULED AT 1:00 AM. STENCIL FACE, RED LETTERS, CLEAR FACE, BRUSHED ALUMINUM )X HALON PHOTOELECTRIC DETECTOR SUB FLOOR 05/28/10 100% SET HOUSING, UNIVERSAL MOUNTING NAMEPLATE DETAIL 3. SHADED SALES LIGHTING AND HALF-SHADED NON-SALES EXI 5 - WITH UNIT LITHONIA LIGHTING CRP-X-RC-X-120/277- AND EMERGENCY BATTERY PACK N/A 9 HALON IONIIZATION DETECTOR CEILING MTD. LIGHTING FIXTURES LABELED WITH"NL/EM"SHALL BE 05/28/10 VT PACKAGE EL N-X SINGLE OR DOUBLE FACE AND NTS .. 5}_ HALON PHOTOELECTRIC DETECTOR CEILING MTD. PROVIDED WITH AN INTEGRAL EMERGENCY BALLAST. ARROWS AS INDICATED ON PLANS. �`T' 07/02/10 100% COMPLETE SET SEE LIGHTING FIXTURE L_!" HALON HORN 96" SCHEDULE NOTE 3 07/28/10 LANDLORD SET HALON BELL 96" L.E.D. EXIT SIGN WITH STENCIL 08/13/10 PERMIT/BID SET 0 HALON ABORT/SNATCH 48" FACE, RED LETTERS, WHITE POLYCARBONATE FACE AND 12112 HALON CONTROL PANEL 6'-0" TO TOP EX2 5 - WITH UNIT LITHONIA LIGHTING LQMSW3R120/277 HOUSING, UNIVERSAL MOUNTING N/A 4 04 HALON HORN/STROBE 96" AND EMERGENCY BATTERY PACK SINGLE OR DOUBLE FACE AND G A HALON GRAPHIC ANNUNCIATOR 6'-0" TO TOP ARROWS AS INDICATED ON PLANS. NOTE 3. (D DOOR CONTACTS (SECURITY) CONCEALED AS REM). SELF CONTAINED 12 VOLT © WINDOW DETECTOR (SECURITY) SOUND & VIBRATION] CEILING MTD. EMERGENCY FIXTURE WITH(2) 35W LAMPS AND LEAD-CALCIUM 013 WINDOW CONTACTS (SECURITY) AS REQUIRED BATTERY LISTED FOR 90 MINUTES. FIXTURE SHALL BE VERIFY ON O REMOTE F.A. - ANNUNCIATOR PANEL AS REQUIRED EM 70 2 WITH UNIT LITHONIA LIGHTING VEL1270-H3512 PROVIDED AS SPECIFIED. NO N/A LIGHTING PLANS SUBSTITUTIONS PERMITTED. Gin FIRE ALARM PANEL AS REQUIRED • PAINT UNIT TO MATCH CEILING. 40MS OCCUPANCY MOTION SENSOR SWITCH 48" SEE LIGHTING FIXTURE ' SCHEDULE NOTE 3 NOTE: IN HANDICAPPED AREAS, THE RECEPTACLES AND TELEPHONE OUTLETS SHALL BE MOUNTED AT 24" A.F.F.; THE TOGGLE SWITCHES, THERMOSTATS AND MANUAL MOTOR STARTERS SHALL BE MOUNTED AT 42" A.F.F. OBLACK MONO-POINTS ARE TO BE USED WITH BLACK TRACK HEADS. OWHITE MONO-POINTS ARE TO BE USED WITH WHITE TRACK HEADS. .0, ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL CORD AND PLUG ON FIXTURES LOCATED IN POP-OUT WALLS FOR CONNECTION TO RECEPTACLES. O4 FIXTURES LABELED "NL" ARE TO BE PROVIDED WITH MANUFACTURER'S NIGHT LIGHT BALLAST. 111:::::::::::. 44122/10038 Scale AS NOTED ALL WIRING MUST BE IN CONDUIT „e,: REK EMT or RIGID FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK"AND AS THE FINAL 1G ,1oal�too, usszaEOl.a.o CONNECTION, FOUR FEET (4 -0 ) MAXIMUM LENGTH, MINIMUM ONE-HALF INCH (1/2") ELECTRICAL TRADE SIZE TO RECESSED FIXTURES, MOTORS AND ELECTRICAL EQUIPMENT THAT MAY GENERATE IIIIIIIIIIIIID:rt2°°° VIn9 No. VIBRATION THROUGH THE CONDUIT SYSTEM. LIGHTING NOTES N AND LIGHTING FIXTURE SCHEDULE I 1 LIGHTING GENERAL NOTES, LIGHTING CODED NOTES AND LIGHTING FIXTURE SCHEDULE NONE 1 Panel Wiring Schedule (3-Phase) ,, Panel Ming Schedule (3-Phase) Panel Vlliring Schedule (3-Phase) Panelboard HP Voltage 277/480 Phase 3 Wire 4 AIC Rating 14.000 Panelboard LP1 Voltage 120/208 Phase 3 Wire 4 AIC Rating 10.000 Panelboard LP2 Voltage 120/208 Phase 3 Wire 4 AIC Rating 10,000 It//1/ Panel Type NF Mains 700A-3P MCB Mains Rating 800 AMP, Panel Type NOOD Mains 100A-3P MCB Mains Rating 225 AMP Panel Type NQOD Mains 50A-3P MCB Mains Rating 125 AMP NEMA Type Enclosure 1 Mounting SURFACE Options Note NEMA Type Enclosure 1 Mounting SURFACE Options Note NEMA Type Enclosure 1 Mounting SURFACE Options Note Ckt. Brkr Brkr N.E.C. Actual Actual N.E.C. Brkr Brkr Ckt. Ckt. Brkr Brkr N.E.C. Actual Actual N.E.C. Brkr Brkr Ckt. Ckt. Brkr Brkr N.E.C. Actual Actual N.E.C, Brkr Brkr Zone Ckt. Zone Load Description Size Phase Size Load Description Zone Zone Load Description Size Phase Size Load Description Zone Zone Load Description Size Phase Size Load Description Zo No. Opts KW KW KW KW Opts No. No. Opts KW KW KW KW Opts A No. No. Opts KW KW KW KW Opts A No.• 7: 1 M 13.296 13.296 A 9.609 9.609 2 1 MONOPOINT-1ST LEVEL 1.144 1.144 A --- --- SPARE 2 1 SIGN LO 1.200 1.200 A 0.546 0.546, SW TRACK LTS 2 3 RTU-1 50/3 HACR 13.296 13.296 B 8.901 8.901 70J3 XFMR T-1 4 3 MONOPOINT-1ST LEVEL 1.320 1,320 B 0.477 0,477 COVE LTG-1ST LEVEL 4 3 SHOW WIND REC LO 0.720 0.720 B 0.390 0.390 SW TRACK LTS 4 5 13,296 13.296 C 9.170 9,170 6 5 �MONOPOINT-1ST LEVEh 1.144 1.144 C 0.564 0.564 COVE LTG-1ST LEVEL 6 5 SHOW WIND REC - 0.720 0,720 C 0.64 0,648 FR MIRROR LTS-1ST LEVEL 6 7 13,296 13.296 A 11007 11.007 8 7 MONOPOINT-1ST LEVEL 1.100 1.100 A 0.480 0.480 COVE LTG-1ST LEVEL 8 7 SPARE __- ___ A --- --- SPARE 8 I 9 RTU-2 50/3 HACR 13.296 13.296 B 10.666 10.666 50/3 XFMR T-2 10 9 MONOPOINT-1ST LEVEL, 1.100 1.100 B 0.486 0.486 COVE LTG-1ST LEVEL 10 9 SPARE _ B 0.144 0,144 FR MIRROR LTS-MEZZ 10 11 M 13.296 13.296 C 11,174 11.174 12 11 MONOPOINT-MEZZ 1.540 1.540 C 0.357 0.357 COVE LTG-1ST LEVEL 12 11 SPARE --- --- C --- --- SPARE 12 13 13.296 13.296 A 4.520 4.520 14 13 MONOPOINT-MEZZ 1.760 1.760 A 0.351 0.351 COVE LTG-1ST LEVEL 14 13 SPARE ___ ___ A _-- ___ SPARE 14 15 RTU-3 50/3 HACR 13.296 13.296 B 4.160 4.160 30/3 XFMR T-3 16 15 MONOPOINT-MEZZ 1.452 1.452 B 0.348 0.348 COVE LTG-1ST LEVEL 16 15 SPARE B SPARE 16 17 13.296 13.296 C 4.520 4.520 18 17 MONOPOINT-MEZZ 0.660 0.660 C 0.318 0.318 COVE LTG-1ST LEVEL 18 17 SPARE --- --- C -- -- SPARE 18 U5220 19 t 13.296 13.296 A 7.330 7.330 20 19 MONOPOINT-MEZZ 1.672 1.672 A 0.480 0.480 COVE LTG-1ST LEVEL 20 19 SPACE __ --- ___ A --- ___ _` SPACE 20 21 RTU-4 50/3 HACR 13.296 13.296 B 7.182 7.182 50/3 PANEL "LP3" 22 21 MONOPOINT-MEZZ 1.320 1,320 B 0.384 0.384 COVE LTG-MEZZ 22 21 SPACE B SPACE 22 WASHINGTON SQUARE 23 $ 13,296 13.296 C 6.997 6.997 24 23 MONOPOINT-MEZZ 0.704 0.704 C 0.546 0.546 COVE LTG-MEZZ 24 23 SPACE -- --- --- C --- ---- -- SPACE 24 25 18,476 18.476 A 11.040 11.040 26 25 SPARE --- --- A 0.396 0.396 COVE LTG-MEZZ 26 25 SPACE -- -- --- A --- --- -- SPACE 26 9585 S.W. Washington Square 27 RTU-5 1 70/3 HACR 18.476 18.476 B 11.040 11.040 60/3 iELEVATOR 28 27 SPARE --- --- B 0.285 0.285 COVE LTG-MEZZ 28 27 SPACE --- ___ ___ g ___ ___ -- SPACE 28 SUITE H08 29 18.476 18.476 C 11.040 11.040 30 29 SPARE --- --- C 0.420 0.420 COVE LTG-MEZZ ' 30 29 SPACE -- -- --- C --- --- -- SPACE 30 PORTLAND, OR 97223 31 18.476 18.476 A 6.072 6.072 32 31 SPARE --- --- A 0.480 0.480 COVE LTG-MEZZ 32 33 RTU-6 M 70/3 HACR 18.476 18.476 B 6.072 6.072 30/3 ESCALATOR 34 33 SPARE --- --- B 0.345 0.345 COVE LTG-MEZZ 34 Notes Breaker Options: CLASS: RED 35 18.476 18.476 C 6.072 6.072 36 35 SPARE --- --- C 1.053 1.053 POP-OUT WALL 36 •All circuit breakers to be 20-Amp, 1-Pole unless otherwise noted. AS - Powerlink AS Breaker 37 13.296 13.296 A --- --- SPACE 38 37 SPARE --- --- A -- --- SPARE 38 LO - Handle lock-off device 39 RTU-7 50/3 HACR 13.296 13.296 B --- --- SPACE 40 39 BOXWALL LTG '20/2 0.130 0.130 B --- --- SPARE 40 Actual Load Totals:0A 1,746 kw N.E.C. Connected Totals:0A 1.746 kw ST - Shunt Trip Type 41 13.296 13.296 C --- --- SPACE _ 42 41 0.130 0.130 C 0.366 0.366 _COVE LTG-1ST LEVEL 42 08 1.254 kw 0B 1.254 kw AUX - Auxiliary Contacts OC 1.368 kw OC 1.368 kw PA - Handle Padlock Attachment Notes Breaker Options: Notes Breaker Options: Total 4.368 kw Total 4,368 kw GFCI - Ground gFaul� Circuit Interrupter HACR - Heating, A C & Refrigeration •All circuit breakers to be 20-Amp, 1-Pole unless otherwise noted. AS - Powerlink AS Breaker •All circuit breakers to be 20-Amp, 1-Pole unless otherwise noted. AS - Powerlink AS Breaker LO - Handle lock-off device LO - Handle lock-off device (All Phases to be balanced to within 7% using Actual Load Totals.) NOTE Actual Load Totals:OA 153.564 kw N.E.C. Connected Totals:0A 154.668 kw ST - Shunt Trip Type Actual Load Totals:OA 7.863 kw N.E.C. Connected Totals:OA 7.863 kw ST - Shunt Trip Type OB 152.007 kw OB 152.667 kw AUX - Auxiliary Contacts OB 7.647 kw OB 7.647 kw AUX - Auxiliary Contacts PA - Handle Padlock Attachment PA - Handle Padlock Attachment SEE L I GHT INC CONTROL SCHEDULE ON SHEET �C 152,959 kw �C 152.959 kw 0C 7,802 kw �C 7,802 kw GFCI - Ground Fault Circuit Interrupter GFCI - Ground Fault Circuit Interrupter E4.4 FOR L I GHT I NG ZONE CR I TER I A. Tota1458,530 kw TotoI46O,294 kw HACR - Heating, A/C & Refrigeration Total 23,312 kw Total 23.312 kw HACR - Heating, A/C & Refrigeration (All Phases to be balanced to within 7% using Actual Load Totals.) (All Phases to be balanced to within 7% using Actual Load Totals.) 904' SEE LIGHTING CONTROL SCHEDULE ON SHEET E4,4 FOR LIGHTING ZONE CRITERIA, ': Panel Wiring Schedule (3-Phase) Panel W Schedule (3-Phase) Panel WIring Schedule (3-Phase)CRITERIA, ',.,, 7' , . Panelboard LP3 Voltage 277/480 Phase 3 Wire 4 AIC Rating 14,000 Panelboard A Voltage 120/208 Phase 3 Wire 4 AIC Rating 10.000 Panelboard B Voltage 120/208 Phase 3 Wire 4 AIC Rating 10.000 ; , �`' }` Panel Type NF Mains 125 AMP MLO Mains Rating 125 AMP Panel Type N*OD Mains 90A-3P MCB Mains Rating 225 AMP, Panel Type NQOD Mains 60A-3P MCB Mains Rating 225 AMP \ ,a\'" Q NEMA Type Enclosure 1 Mounting SURFACE Options Note NEMA Type Enclosure 1 Mounting SURFACE Options Note NEMA Type Enclosure 1 Mounting SURFACE Options Note `*.'4 a,'Ai , Y . , Ckt. Brkr Brkr N.E.C. Actual Actual N.E.C. Brkr Brkr Ckt. Ckt, Brkr Brkr N.E.C. Actual Actual N.E.C. Brkr Brkr Ckt. Ckt, Brkr Brkr N.E.C. Actual Actual N.E.C. Brkr Brkr Ckt. Zone Load Description Size Phase Size Load Description Zone Zone Load Description Size Phase Size Load Description Zone Zone Load Description Size Phase Size Load Description Zone No. Opts KW KW KW KW Opts A No. No. A Opts KW KW KW KW Opts A No. No. A Opts KW KW KW KW Opts A No. 1 SALES DNLTS-1ST LEVEL 0.920 0.920 A --- --- SPARE 2 1 DS-1/ACCU-1 LO 1.800 1.800 A 0.800 0.800 LO HVAC/LTG CTL PNLS 2 1 ROLLING GRILLE LO 1,127 1.127 A 0.720 0.720 SALES RECS-1ST LEVEL 2 3 SALES DNLTS-MEZZ 1.144 1.144 B 0.754 0.754 FR DNLTS-1ST LEVEL 4 3 SPARE ---- --- B 1.250 1.250 LO 20/2!WH-1 4 3 CW REC-1ST LEVEL 0.500 0.500 B 0.720 0.720 SALES RECS-1ST LEVEL 4 5 SALES DNLTS-MEZZ 0.732 0.732 C 1.760 1.760 NL'S-1ST LEVEL 6 5 IRONS '20/2 1.000 1.000 C 1.250 1.250 6 5 CW REC 1ST LEVEL 0.500 0.500 C 0.900 0.900 _SALES RECS-1ST LEVEL 6 7 SALES DNLTS-1ST LEVEL 1.056 1.056 A 1.696 1.696 NL'S-MEZZ 8 7 1.000 1.000 A --- --- SPARE 8 7 CW REC-1ST LEVEL 0.500 0.500 A 0.900 0.900 SALES RECS-MEZZ 8 9 SALES DNLTS-1ST LEVEL 1.320 1.320 B 2.688 2.688 NS LTS-NL/EM/EXITS 10 9 RTU LTS/RECS LO 1,120 1.120 B 0.720 0.720 PROCESSING REC 10 9 CW REC-1ST LEVEL 0.500 0.500 B . 0.540 0.540 SALES RECS-MEZZ 10 11 SALES DNLTS-MEZZ 1.302 1.302 C 1.565 1,565 EXIT/EM-1ST LEVEL 12 11 RTU LTS/RECS LO 0.840 0.840 C 1.500 1.500 MICROWAVE 12 11 ESCALATOR LTS LO 0.500 0.500 C 0.900 0.900 SALES RECS-MEZZ 12 H B K 13 SALES DNLTS-MEZZ 0.976 0.976 A 1.300 1.300 EXIT/EM-MEZZ 14 13 EF-1 LO 0.300 0.300 A 1.500 1.500 LO REFRIGERATOR 14 13 SPARE --- --- A 0.100 0.100 ELEVATOR PIT LT 14 1 5 SALES DNLTS-MEZZ 1.276 1.276 B --- --- SPARE 16 ° 15 EF-2 LO 1.127 1.127 B 0.360 0.360 LO EAS 16 15 ESCALATOR LTS LO 0.500, 0.500, B 0.180 0.180 ELEVATOR PIT REC 16 CONSULTANTS, LTS 17 STAIR LIGHTS 1.534 1.534 C 0.104 0.104 ENTRY LIGHTS 18 17 EF-3 LO 0.696 0.696 C --- --- SPARE 18 17 ESC PIT LTS-MEZZ LO 0.200 0.200 C 0.828 0.828 ELEVATOR PIT PUMP 18 Mechanics & Electrical Design services 19 NS LIGHTS 1.382 1.382 A --- --- SPARE 20 19 BUZZER LO 0.360 0.360 A 0.540 0.540 TOILET/HALL REC 20 19 ESC PIT REC-MEZZ LO 0.360 0.360 A 0.500 0.500 ELEV CAB LTG , 20 21 SPARE --- --- B --- --- SPARE 22 21 MTG/SEC RM REC 0.360 0.360 B 0.189 0.189 LO EF-4 22 21 ESC PIT LTS-1ST LEVEL LO 0.200 0.200 B 1.000 1.000 ELEV OIL COOLER 22 23 SPARE --- --- C --- --- SPARE 24 23 ADMIN/MTG/SEC REC 0.720 0.720 C 0.300 0.300' LO VVT'S 24 23 ESC PIT REC-1ST LEVEL , LO 0.360 0.360 C 0.180 0.180 ELEV MACHINE RM REC 24 171 Charring Cross Drive S. 25 SPACE -- --- --- A --- --- -- SPACE 26 25 SPARE --- --- A --- --- SPARE 26 25 CW REC-MEZZ 0.500 0.500 A --- --- SPARE 26 Suite 1B 27 SPACE -- --- --- 6 --- --- -- SPACE 28 27 LOUNGE COUNTER REC 0.360 0.360 B 0.540 0.540 HALL/PROC RECS 28 27 CW REC-MEZZ 0.500 0.500 B --- --- SPARE 28 Westerville, Ohio 43081 614,882,1199 29 SPACE -- --- --- C --- --- -- SPACE 30 29 SPARE --- --- C --- --- SPARE 30 29 CW REC-MEZZ 0.500 0.500 C --- --- SPARE 30 FAX 614,882,1857 31 SPACE -- --- --- A --- ---- -- SPACE 32 31 SPARE --- --- A --- --- SPARE 32 Notes Breaker Options: 33 SPACE _ i_` ®__ B __ =® SPACE 34 33 SPARE __ ___ B _+_ SPARE 34 AS - Powerlink AS Breaker 35 SPACE C SPACE 36 35 SPARE C SPARE 36 A AII circuit breakers to be 20-Amp, 1-Pole unless otherwise noted. - -- - - LO - Handle lock-off device ()ravings and vritten material appearing herein constitute original Actual Load Totals:0A 7.330 kw N.E.C. Connected Totals:0A 7.330 kw ST - Shunt Trip Type Notes Breaker Options: Notes Breaker Options: �B 7.182 kw �B 7.182 kw AUX - Auxiliary Contacts and unpublished cork of the Architect and may not be duplicated, All circuit breakers to be 20-Amp, unless otherwise noted. AS - Powerlink AS Breaker •All circuit breakers to be 20-Amp, 1-Pole unless otherwise noted. AS - Powerlink AS Breaker OC 6.997 kw OC 6.997 kw PA - Handle Padlock Attachment p• GFCI - Ground Fault Circuit Interrupter LO - Handle lock-off device LO - Handle lock-off device u s e d or d i s c l o s e d #i t h o a t w r i t t e n c o n s e n t of t h e A r c h i t e c t Total 21.509 kw Total 21.509 kw p Actual Load Totals:OA 6.300 kw N.E.C. Connected Totals:0A 6.300 kw ST - Shunt Trip Type Actual Load Totals:0A 4,707 kw N.E.C. Connected Totals:OA 4,707 kw ST Shunt Trip Type ®'# B H A R C H l T E C 1 - 2 0 i 0 HACR - Heating, A/C & Refrigeration AUX - Auxiliary Contacts 06 6.026 kw OB 6.026 kw AUX - Auxiliary Contacts 0B 4.640 kw OB 4,640 kw Y (All Phases to be balanced to within 7% using Actual Load Totals.) PA - Handle Padlock Attachment OC 4.868 kw OC 4,868 kw PA - Handle Padlock Attachment OC 6.306 kw �C 6.306 kw Q A Q C NOTE Total 18.632 kw Total 18.632 kw GFCI - Ground Fault Circuit Interrupter Total 14,215 kw Total 14,215 kw GFCI - Ground Fault Circuit Interrupter HACR - Heating, A/C & Refrigeration HACR - Heating, A/C & Refrigeration No. D a l e I s s u e SEE L I GHT I NG CONTROL SCHEDULE ON SHEET (All Phases to be balanced to within 7% using Actual Load Totals.) (All Phases to be balanced to within 7% using Actual Load Totals.) E4.4 FOR LIGHTING ZONE CRITERIA. 05/28/10 100% SET 05/28/10 VT PACKAGE 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET 08/13/10 PERMIT/BID SET Panel Wiring Schedule (3-Phase) Panelboard L1 GA Voltage 120/208 Phase 3 . Wire 4 , AIC Rating 10.000 EQUIPMENT W SCHEDULE Panel Type NQOD Mains 50A-3P MCB Mains Rating 125 AMP NEMA Type Enclosure 1 Mounting SURFACE Options Note SEE NOTES 1. 2. 3 BELOW - FEEDERS TYPE OF BRANCH DISC. BUSS SYM. ITEM VOLTAGE HP, KW. F.L.A. REMARKS Ckt. Zone Load Description B ze Brkr N.E.C. Actual Phase Actual N.E.C. Brkr Size Load Description Zone Ckt. WIRE COND. CONN. BREAKER SW. FUSES No. p A Opts KW KW KW KW Opts A p No. 1 SPARE --- --- A 0.720 0.720 LO DATA RACK 2 1 WATER 208V, 10 -- 2.5 -- 2#12 THHN 3/4" 'AVC�T TOGGLE 20A-2P --- --- 3 ADMIN RECEPTS 0.720 0.720 B 0.500 0.500 LO SECURITY 4 HEATER # 2 GRD SWITCH ALL WIRING MUST BE IN CONDUIT 5 CW REC-1ST LEVEL LO 0.500 0.500 C --- --- SPARE 6 2#12 THHN EMT or RIGID 7 CW REC-1ST LEVEL LO 0.500 0.500 A 0.360 0.360 LO DATA RACK 8 0 EF-1 & 4 120V, 10 FRAC --•- 1#12 1#12 GRD 3/4" DIRECT 20A-1P --- --- 9 CW REC-1ST LEVEL LO 0.500 0.500 B 0.360 0.360 DECO RECEPTS. 10 FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR 11 CW REC-1ST LEVEL LO 0.500 0.500 C 1.800 1.800 LO , SOUND RACK 12 2#12 THHN CONNECTIONS INSIDE CASEWORK AND AS THE FINAL 13 CW REC-1ST LEVEL LO 0.500 0.500 A 0.720 0.720 LO DOOR LOCK 14 EF-2 12OV, 10 1/2 ---- -- 1//12 GRD 3/4" DIRECT 20A-1P -- --- CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, 15 CW REC-MEZZ LO 0.500 0.500 B 0.720 0.720 LO , MTG/SEC RM RECS 16 MINIMUM ONE-HALF INCH (1/2") ELECTRICAL TRADE 17 CW REC-MEZZ LO 0.500 0.500 C 0.720 0.720 ADMIN RECEPTS 18 SIZE TO RECESSED FIXTURES, MOTORS AND 19 EMPLOYEE T,C. LO 0.500 0.500 A 0.720 0.720 ADMIN RECEPTS 20 EF-3 120V, 10 1/4 -- -- 2#12 THHN 1#12 GRD 3/4" DIRECT 20A-1P --- --- ELECTRICAL EQUIPMENT THAT MAY GENERATE 21 MTG/SEC RM RECS LO 0.360 0.360 B 0.500 0.500 ELECTRIC RM REC 22 VIBRATION THROUGH THE CONDUIT SYSTEM. 23 CW REC-MEZZ LO 0.500 0.500 C --- --- SPARE 24 25 CW REC-MEZZ LO 0.500 0.500 A --- --- SPARE 26 0 ELEVATOR 480V, 30 30 -- _ 3#4 THHN 1" DIRECT BOA-3P 2 MI 7 SPARE --- --- B --- ---- SPARE 28 1#10 GRD 29 SPARE --- --- C --- --- SPARE 30 3#10 THHN //4. 30/3 LPS-RK Project No. 44122/10038 Notes ESCALATOR(S) 480V, 30 7.5 -- - - 1#10 GRD DIRECT 30A-3P FDS 20 NM A All circuit breakers to be 20-Amp, 1-Pole unless otherwise noted. Breaker Options: , AS - Powerlink AS B r e a k e r 4 8 0 V, 30 3#6 THW " 50A-3P 60A-3P ___ S c a l e AS NOTED LO - Handle lock-off device 7 RTU-1,2,7 3W -- 39.888 -- 11/10 GRD 1 DIRECT HACR NFDS Actual Load Totals:OA 4.520 kw N.E.C. Connected Totals:OA, 4,520 kw ST - Shunt Trip Type , OB 4.160 kw 0B 4,160 kw AUX - Auxiliary Contacts 480V, 30 3#6 THW 50A-3P 60A-3P ___ D r o w a ll t: REK OC 4.520 kw OC 4,520 kw PA - Handle Padlock Attachment 0 RTU-3,4 3W -- 40,719 -- 1#10 GRD 1 DIRECT HACR NFDS Total 13.200 kw Total 13.200 kw GFCI - Ground Fault Circuit Interrupter SEE SHEET "E0.4" FOR ADDITIONAL HACR - Heating, A/C & Refrigeration 480V, 30 3#4 THW / 70A-3P 100A-3P NNW__ PANEL SCHEDULES AND EQUIPMENT (9 RTU-5,6 -- 55.42E -- 1 1 4 DIRECT SC DULES A D EQUIPME (AII Phases to be balanced to within 7% using Actual Load Totals.) 1, Provide with feed thru lugs for TVSS unit. `-' 3W, 1#8 GRD HACR NFDS 2. Provide with 200% neutral bus. WIRING SCHEDULE. J\2010 JCbs\1oo3\usz�O2.d.g 3. Provide insulated/isolated ground bar separate from regular ground bar. Drawing N o. PANEL SCHEDULES cf NONE i PANEL SCHEDULES AND EQUIPMENT WIRING SCHEDULE .. 1 L , , A _ ELECTRIC LOAD SUMMARY 277/480v » �� "1"2" 12o/208v "T3" 12o/208v "V4114 SYSTEM LIGHTING TRANSFORMER T1 LOAD SUMMARY 120/208V SYSTEM POWER TRANSFORMER LOAD SUMMARY SYSTEM I.G. TRANSFORMER LOAD SUMMARY SYSTEM ACTUAL ACTUAL N.E.C. N.E.C. N.E.C. ACTUAL ACTUAL N.E.C. N.E.C. N.E.C. ACTUAL POWER ACTUAL N.E.C. N.E.C. N.E.C. ACTUAL POWER ACTUAL N.E.C. N.E.C. N.E.C. POWER POWER DESCRIPTION CONNECTED DEMAND CONNECTED DEMAND DEMAND DESCRIPTION CONNECTED DEMAND CONNECTED DEMAND DEMAND DESCRIPTION CONNECTED DEMAND CONNECTED DEMAND DEMAND DESCRIPTION CONNECTED DEMAND CONNECTED DEMAND DEMAND FACTOR FACTOR FACTOR FACTOR KW/KVA KVA KW/KVA FACTOR KVA KW/KVA KVA KW/KVA _ FACTOR KVA KIN/KVA KVA KW KVA FACTOR KVA KW/KVA KVA KW/KVA FACTOR KVA LIGHTING 49.753 A 62.191 49.753 1.25 62.191 LIGHTING 27.680 1.0 34.600 29.444 1.25 36.805 LIGHTING 1.500 1.0 1.875 1.500 1.25 1.875 LIGHTING --- 1.0 --- --- 1.25 --- SHOW WINDOW * 10.500 RECEPTACLES ___ 1.0 1.0 < 10Kw ___ RECEPTACLES 22.508 1.0 16.254 22.508 1.0 < 10KW 16.254 RECEPTACLES 12.480 1.0 11.240 12.480 1.0 < 10KW 11.240 LIGHTING ALLOWANCE 0.936 A 1.170 8.400 1.25 --- --- 0.5 REMAINING KW 0.5 REMAINING KW 0.5 REMAINING KW 1,Q < 1QKW 10 I 1.0 1.0 RECEPTACLES 34,988 1,0 22.494 34,988 22.494 MOTORS ___ ___ ___ -- MOTORS 3,439 0►9 3.821 3.439 +25* LARGEST 3.621 MOTORS --- 0.9 --- --- +25% LARGEST _-- 0.9 REMAINING KW ��9 +25% LARGEST 1.0 FIXED ELECTRIC FIXED ELECTRIC FIXED ELECTRIC ___ MOTORS 54,775 0.9 60.861 54.775 60.861 * 1.0 * * 1.0 __- o * 1.0 * 1.0 --- o --- * 1.0 --- * --- '* 1.0 0 +25% LARGEST SPACE HEATING --_ `__ `__ SPACE HEATING -_-- ___ ___ SPACE HEATING FIXED ELECTRIC AIR CONDITIONING 1.0 ** AIR CONDITIONING +25�1L0 ** AIR CONDITIONING _-_ --- --_ 1. ** ___ SPACE HEATING --- * 1.0 ---* -`- * 1.0 ___* SYSTEM "` * 1.0 "_ * "` +25% LARGEST _ SYSTEM 1.800 1,0 1,800 1.800 1.800 1.0 +25% LARGEST AIR CONDITIONING 1.0 *** ELECTRIC WATER ELECTRIC WATER ELECTRIC WATER __ 313.758* 1.0 313.758* 313.758 * 313.758* 1.0 -- 1.0 --- 2.500 1.0 2.500 2.500 1.0 2.500 --- 1.0 --- 1.0 -- US220 SYSTEM (HT. PUMP) +259 LARGEST HEATER -_` -" HEATER HEATER _-_ ELECTRIC WATER HEATER `-` --- --- --_ ' WASHINGTON 2.500 1.0 2.500 2.500 1.0 2.500 MISCELLANEOUS 1,p 1 0 MISCELLANEOUS 1.100 1.0 1.100 1.100 1 0 1 100 MISCELLANEOUS 0.720 1.0 0.720 0.720 1.0 0.7 0 ■ SQUARE MISCELLANEOUS 1.820 1.0 1.820 1.820 '1.0 1.820 TOTAL 27.680 34.600 29.444 36.805 TOTAL 32.847 27.350 32.847 27.350 TOTAL 13.200 11.960 13.200 11.960 9585 S.W. Washington Square TOTAL 458.530 464.794 465.994 474.124 " SUITE H08 NOTES NOTES NOTES NOTES * USE GREATER VALUE OF THE TWO CATEGORIES * USE GREATER VALUE OF THE TWO CATEGORIES * USE GREATER VALUE OF THE TWO CATEGORIES PORTLAND, OR 97223 * USE GREATER VALUE OF THE TWO CATEGORIES CL RED ** 125% OF THE LARGEST MOTOR OF COMPRESSOR IN SYSTEM. APPLIED ONLY ON ONE UNIT. ** 125% OF THE LARGEST MOTOR OF COMPRESSOR IN SYSTEM. APPLIED ONLY ON ONE UNIT. ** 125% OF THE LARGEST MOTOR OF COMPRESSOR IN SYSTEM. APPLIED ONLY ON ONE UNIT. CLASS: ** N.E.C. ARTICLE 220-12 REQUIREMENT (200VA PER FOOT OF SHOW WINDOW) MINUS ACTUAL INSTALLED SHOW WINDOW LIGHTING VA. *** 125% OF THE LARGEST MOTOR OF COMPRESSOR IN SYSTEM. APPLIED ONLY ON ONE UNIT. USE 45 KVA TRANSFORMER USE 30 KVA TRANSFORMER USE 15 KVA TRANSFORMER A POWER FACTOR IS ALREADY INCLUDED IN LIGHTING LOAD. N.E.C. DEMAND KVA x 1000 = MINIMUM FEEDER AMPERAGE SYSTEM VOLTAGE x NOTE FEEDER KEY 474.124 x 1000 = 570.3 AMPS USE 700 AMP SERVICE 480 x 1.73 THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT INTO THE EXISTING STRUCTURE IN SIZE OF POWER SIZE OF THE GRD. /7-' '--/, - THE MANNER INTENDED AND SHOWN ON THE CONDUCTOR CONDUCTOR DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT \ f F , ARE CONTRARY TO THOSE ON THE DRAWINGS, THE A 9, e{ ` . _ ,,. POWER RISER DIAGRAM ELECTRICAL CONTRACTOR SHALL NOTIFY THE "H & 3 - 8 - 1 -'� 1 0 '-' 3/4, , M' i ��,�GENERAL NOTES M" CONSTRUCTION MANAGER PRIOR TO FABR I CATION -- I OF r a �-1 Zf1�°� ¢" OR PERFORMING ANY WORK IN THE AREA INVOLVING SIZE 0 Y , 1 HVAC CIRCUIT BREAKERS SHALL BE "HACR" TYPE WHERE REQUIRED DIFFERENCES. NOT I F I CAT I ONSHALL BE I N THE QUANTITY OF POWER QUANITY OF GRD. CONDUIT ', f'; BY EQUIPMENT NAMEPLATE PER N.E.C. FORM OF A DRAWING OR SKETCH INDICATING FIELD CONDUCTOR CONDUCTOR \''':ft ',/ MEASUREMENTS AND NOTES RELATED TO THE AREA• THUS: RUN 3 #8 THW AND 1 #10 GRD. IN 3/4" CONDUIT ' 2 ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXACT K.A.I.C. RATING OF LANDLORDS DISTRIBUTION EQUIPMENT, FURNISH AND SYMBOL FEEDER ITEM SEED INSTALL "H & M" SYSTEM TO MATCH. E"1 PARALLEL (2) SETS PANEL "HP" 3 ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ALL WIRING MUST BE IN CONDUIT .:/ 4-500-1-2/0-3" PER SET ELECTRICAL EQUIPMENT TO 7% (+) BETWEEN PHASES: A/B, B/C, A/C REGARDLESS OF CIRCUITING INDICATED. EMT or RIGID 3-10-1-10-3/4" XFMR "T3" 4 PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR Lr./ 3-6-1-10-3/4" XFMR "T2" EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE CONNECTIONS INSIDE CASEWORK AND AS THE FINAL AVAILABLE IN ELECTRICAL ROOM/AREA PRIOR TO INSTALLATION OF CONNECT ION, FOUR FEET (4'-0") MAXIMUM LENGTH, "„ „ H B K ELECTRICAL EQUIPMENT. MINI MUM ONE-HALF I NCH (1/2") ELECTRICAL TRADE ��./ 3-4-1-8-1 XFMR T1 5 ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL SIZE TO RECESSED U I P E I T THAT MOTORS RAD " " " CONSULTANTS, LTD FOR A COMPLETE ELECTRICAL Y T M ELECTRICAL EQU 1 PMENT THAT MAY GENERATE � 4-1-1-6-1 1/2" PANEL LP1 Mechanical & Electrical Design Services CONNECTIONS 0 CO LEE ELEC C LSSE . V I BRAT I ON THROUGH THE CONDU I T SYSTEM. 0 4-2-1-8-1 1/4" PANEL "A" 171 Charring Cross Drive S. 7 4-4-1-8-1 1/4" PANEL "6" Suite 1B Westerville, Ohio 43081 ELECTRICAL CONTRACTOR TO BALANCE TRANSFORMERS TO 614.882.1199 SUPPLY 120V±3% AFTER ALL CONNECTIONS ARE MADE AND NOTE 8® 4-6-1-8-1" PANEL "LP2" FAX 614,882,1857 RUNNING. PROVIDE BALANCE SHEET TO "H & M" CONSTRUCTION MANAGER AT PUNCHLIST. I T I S THE ELECTRICAL CONTRACTOR'S g #8 THHN GRD TO BLDG STEEL XFMR "T3" GROUND RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN PHASES REGARDLESS OF THE CIRCUIT SHOWN. 10 #6 THHN GRD TO BLDG STEEL XFMR "T2" GROUND Drawings and written materiel appearing herein constitute originol end unpublished work of the Architect and mow not be duplicated, 11 #6 THHN GRD TO BLDG STEEL XFMR "T1" GROUND used or disclosed without written consent of the Architect M ARCHITECT - 2010 ...... ..... 12 4-6-1-8-1" PANEL "LP3" QAOC 5-6-2-8-1" (3)PHASE CONDUCTORS, No. Dote Issue 13 (2)PARALLEL NEUTRAL PANEL "L1GA" • CONDUCTORS, (1 )GROUND 05/28/10 100 SET 4 CONDCUTOR AND (1)I SOLATED 05/28/10 VT PACKAGE GROUND CONDUCTOR LEASE LINE / / .- .. 07 02 10 100% COMPLETE SET 07/28/10 LANDLORD SET L®L. H & M SPACE 08/13/10 PERMIT/BID SET 15 KVA ISOLATION STEP-DOWN XFMR. UNISTRUT FRAME ANCHORED TO STACKED ON UNISTRUT FRAME, 480 FLOOR AND STRUCTURE ABOVE AS VOLT, 3-PHASE, 3-WIRE PRIMARY, 0 BY LANDLORD DIRECTED BY LANDLORD. _...._ 120/208 VOLT, 3-PHASE, 4-WIRE SECONDARY. r , "'"- ,,,.a.,1 ROOF r 'r 0 r 1 (2) 0 METERING FURNISHED AND INSTALLED 40 BY LANDLORD. 12 13 0 . , . , , 0 PNL "HP" PNL "LP3" PNL "L1GA" T3 PNL "LP1" PNL "LP2" PNL "A" PNL "B" METERING C/T'S FURNISHED AND I 277/480V 277/480V 120/208V �wa 120/208V 120/208V 120/208V 120/208V no INSTALLED IN SWITCHBOARD BY I �M� -i 30, 4W 30, 4W 30, 4W I-- - - --- L-I 30, 4W 30, 4W 30, 4W 30, 4W I 44122/10038 LANDLORD. Project N o. I I 700 AMP 225 AMP 50 AMP I s 100 AMP 50 AMP 90 AMP 60 AMP IMIN I M.C.B. M.L.O. M.C.B. I I I M.C.B. M.C.B. M.C.B. M.C.B. EXISTING LANDLORD SWITCHBOARD I -- --1 -i-2 S c a l e AS NOTED LOCATED IN LANDLORD'S ELECTRICAL I --700A-3P CIRCUIT BREAKER TRANSIENT VOLTAGE SURGE SUPPRESSOR ( �1 10 ROOM IN NEW EXPANSION PORTION OF FURNISHED AND INSTALLED TVSS FURNISHED AND INSTALLED BY r i MALL.. I ) 5 Dro•w8r: REK 0 BY LANDLORD. ELECTRICAL CONTRACTOR, SQUARED M ODEL "TVS2XGA24A-I-D-M-S" OR ( ( I I $u-a.Z.A APPROVED EQUAL. J s. I Ti I, 11 I FLOOR ,r:�soao Jobt\100.>8\tlS220E43.dp r I 1 iiiiiiiiiiii II, , 73 0 30 KVA STEP-DOWN XFMR, STACKED 45 KVA STEP-DOWN XFMR. MOUNTED D r a w i n g No. Iz ON UNISTRUT FRAME, 480 VOLT, ON FLOOR, 480 VOLT, 3-PHASE, POWER RISER 3-PHASE, 3-WIRE PRIMARY, 120/208 VOLT, - / VERIFY EXACT DISTANCE IN FIELD 3-WIRE PRIMARY, "i. ► 120/208 VOLT, 3-PHASE, 4-WIRE 3-PHASE, 4-WIRE SECONDARY. AND LOAD SUMMARIES SECONDARY. I r= POWER RISER AND LOAD SUMMARIES NONE ' 1 EO.3 It RATED WALL , �___ 1. COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS IN THE CALIFORNIA BUILDING CODE AND LOCAL BUILDING CODES, 1" FIBERGLASS INSULATION UNLESS REQUIREMENTS IN THIS SECTION ARE MORE • THRU WALL ONLY STRINGENT. #12 AWG CEILING HANGER 2. PROJECT SEISMIC ZONE AND ZONE FRACTOR AS DEFINED IN (E) OR (N) CONDUIT �'�— WIRE TO STRUCTURE UBC:ZONE 4,ZONE FACTOR 0.4 .... (TYP. ALL CO'. :S OCCUPANCY CATEGORY AS DEFINED IN UBC:IV 7ga 41 I SEISMIC IMPORTANCE FACTOR:1.5 1 WIND IMPORTANCE FACTOR:1.0 ACCELERATION FACTOR;gNT,45E FOR FtlGII�?EQUIPMENT 71 ACCELERATION FACTOR: 3. COORDINATE LAYOUT AND INSTALLATION OF SEISMIC 1 .� .i BRACING W}TH BUILD}NG STRUCTURAL SYSTEM AND I I i iii" `� ARCHITECTURAL FEATURES,ANO WITH MECHANICAL, FIRE- :.:., PROTECTION,ELECTRICAL,AND OTHER BUILDING FEATURES 3M BRAND FIRE BARRIER ti:. IN THE vICIMTY.• CP25WB+ CAULK OR EQUAL. ''°' COMPLETELY FILL ANNULAR 4. ACCEPTABLE MANUFACTURERS FOR SEISMIC BRACING US220 .-, SPACE BETWEEN CONDUIT & . ;• RECESSED LIGHT FIXTURE DEVICES: B-LINE ESYSTEMS,INC. WALL AND LEAVE A MIN. _. IN LAY—IN CEILING ERICO,INC. WASHINGTON SQUARE ,..- �- 5/8" BEAD AROUND BOTH '� (TYP), GS METALS CORP. OUTSIDE FACES OF WALL MASON R INC.THOMAS BETTS 9585 S.W.�+Washington Square UNISTRUT CORPORATION. SUITE H08 PORTLAND, OR 97223 UNINSULATED — UL SYSTEM WL 1001 INSULATED — UL SYSTEM WL 5039 CLASS: RED C2 RECESSED LIGHT SEISMIC DETAIL E0.4 NTS NOTE: INSTALLATION TO FOLLOW UL SYSTEM WL 1001 OR WL 5039 AND BE A UL TESTED ASSEMBLY. ECONDUIT THRU FIRE WALL PENETRATION DETAIL E0.4 NTS '� ' g'( ° aaQ \„, ' 0r-:,::(ini.1/41 / i H B K , CONSULTANTS, LTD Mechanical & Electrical Design Services 171 Charring Cross Drive S. Suite 1B Westerville, Ohio 43081 614.882,1199 FAX 614,882,1857 °ravings and rritlen material appearing herein constitute original and unpublished 'orb of the Architect and may not be duplicated, used or disclosed rithout at ritten consent of the Architect ®MBH ARCHITECT - 2010 OAOC No. Dale Issue 05/28/10 100% SET 05/28/10 VT PACKAGE 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET 08/13/10 PERMIT/BID SET mom • 4 Project No. 44122/10038 Stole AS NOTED I/ro■KBy: REK ALL WIRING MUST BE IN CONDUIT EMT or RIGID k FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR 'Mato dabs\10038\uS220E04.d.9 1 CONNECTIONS INSIDE CASEWORK AND AS THE FINAL Y CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, P.. MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE Droving No. r SIZE TO RECESSED FIXTURES, MOTORS AND ELECTRICAL ELECTRICAL EQUIPMENT THAT MAY GENERATE - i VIBRATION THROUGH THE CONDUIT SYSTEM. DETAILS AND SCHEDULES NONE I ELECTRICAL DETAILS AND SCHEDULES _ i E 0.4 ODD ' • BB • AA • 0 • 0 illaM 1 I I I I I 1 I I I I I I I I ADJACENT US220 I I I I I TENANT- .LC. I I I WASHINGTON SQUARE 9595 aw. Washinoton Square I I I J _ _ _1 _ _ _ _1 _ _ _ _I _ _ U _ 8ITE HOB _— ,- - _ I AL__ii 0 1. I I EVERYDAY nip ,. CL�A 'D I I I a - a I I a a M (IN� LL) / •ii 1 HMV I I I E?:M Iv' LP3-• EM,■ Oda EM■; EVERYDAY, i : % !!1 NO �� _ I�.r ■ .�, _ .1 Ill110 0: r-�� I — _ 38 _ 17::::::-- �I-` -- ��'Tii - - -_ ='���1._.;1i 1 . - Ilfl _ I� - f ,�_1l'A�� � — 1��I ' • ■I pENIM I I 1 NL , / I III NL NL NL III , WO ENS !iJ I. MACHINE r_ n ■■■.■. SALE§ AREA ��� I 1 \ / `- ROOM �.�m LP3-1 LP3 7 Q a a NL LP3 18 +. 1 •, ■—•1■% MP. m FITTING I i, 4EX "''':"'"7, :',10 ,/,,..:/, 3/4 CONN I T FROM ROOMS �.� I #ME L I GHTSTAT MOTION SENSOR' '7 EVERYDAY . ����� _-- EVERYDA 11311°!P�� . ���1..•, TO LIGHTSTAT #_I GHT t NC . 1 ao a d Q CONTROL PANEL 1 N �'�ELEC7RtO: ROOM ..N L ;; 4 � ! I NL NL NL 1111 , \ / I -n x ill l ; - _ . .- Ill Q MALL COMMON ,-767`r IP; Q Ot N -I 3--4 =----- ■m m /I ■. EM (I N :��VE E x 1 AREA NM. � ` r le i NL EM EM EM i I M Nit � - S �� Q Q � .. : .m m a 1 a /1"." • L / ` � :va>c e. i!O! _ EX1 i t LP.0 gnu-I I N■ WOMENS T T MO ON SENSOR 3/4" :CONDU I " •F.ROt . mor• LIGH S AT Ti R' --- ._ . _ rr. r� — �� ... ._ �.. _... ri --; 1''O L I GHTSTA� :L I GI-T l NG' — — - =r♦ r>:r la `� �! J CONTROL PANEL IN..... ROOMS 1 ! I��fl a < •Q < .°,,• N ELECTR!C ROOAi[; ... linLila,',EM ■■ Q •a um Q EM WOMENS ;, w-.,I • EM --r - _ ,m ■ail= SALES AREA LADMODERN I E3 KW' 1 V I a iIi ..r..• ... • DIV. ACC, + 011111111 / 1111 CONSULTANTS, LTD NL NL NL NL NL 1 1 I, I ■ LAD. MODERN EM ■' Mechanical & Electrical Design Services xi : m ��� �. Lo.G.G. I I ► ii ! � i CLASS \ I 11 I■ ' `� i Q a a 1 I�� • ♦a Q ♦Q Q N Y 1c6"11 L. • • "I I'1I 1 INL NL WL ` 6 ring Cross Drive S. �" Westerville, Ohio 43081 Al , Ili 614.882.1199 I!! r■b.. M EM _ _ .1......., aa.. NL I I �� ,�- ___ginIIIIIIIII FAX 614,882.1857-------....... I NL NL L • ' � • STAIRS • J .. '_ � 6111111■■-• '� i�'l '—I m m I I I ,1 M I ( L ��_ .� ___ ___ �,-1_ Ja I Drartings and mitten notarial appearing herein constitute original " �'� —_— -- - ` - - J - unpublished cork of the Architect end mor not be duplicated,36 I I I I 1 UP TO STAIR IN` ' _ EM ( used or disclosed without written consent of the Architect LIGHTS ON WALL) (e O MBH ARCHITECT - 2010 ,. _, JUNCTION BOX FOR MIRROR LIGHT. 3/4" CONDUIT FROM ADJACENT MEZZANINE. COORDINATE EXACT REQUIREMENTS L'GHTSTAT MOTION SENSOR TENIANT_N.LC. I WITH H&M CONSTRUCTION MANAGER TO LIGHTSTAT LIGHTING OM IN FIELD PRIOR TO ROUGH—IN CONTROL PANEL IN (TYP. OF 9). ELECTRIC ROOM. NOTE TE No. Dote Issue 05/28/10 100% SET SEE SHEET "E0. 1 " FOR LIGHTING CODED 05/28/10 VT PACKAGE NOTES AND LIGHTING GENERAL NOTES. 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET NOTE 08/13/10 PERMIT/BID SET IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN PHASES REGARDLESS OF THE CIRCUIT SHOWN. ALL WIRING MUST BE IN CONDUIT EMT or RIGID FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK AND AS THE FINAL CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE SIZE TO RECESSED FIXTURES, MOTORS AND ELECTRICAL EQUIPMENT THAT MAY GENERATE VIBRATION THROUGH THE CONDUIT SYSTEM. NOTE THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT INTO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT Project No. 44122/10038 ARE CONTRARY TO THOSE ON THE DRAWINGS, THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE "H & SCele AS NOTED M" CONSTRUCTION MANAGER PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATIONSHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD Drowsily: REK MEASUREMENTS AND NOTES RELATED TO THE AREA. 1 a N JA2010 Jobs\too,' US220E21o.d.g $ 111111111 fri (1) Drawing No. rt ELECTRICAL VERIFY ALL CONDITIONS IN FIELD PRIOR TO BIDS. LIGHTING PLAN FIRST LEVEL ELECTRICAL LIGHTING PLAN FIRST LEVEL 1/8104Y' 1 2 . E2.1a Alk iligirdisiormalVERIFY ALL CONDITIONS IN FIELD PRIOR TO BIDS. 14/4/1/ C IMF/M PAISI 1 _ _ EM tk■� �\//�i�i��■,�`''f__I 11,11111111111ZM!911111111111111VJMIME 110111111111111111111E21111110111111111111111113111111, iilmispraniumm:z/miI DD BB AA CJ 0 ■MA ,i.1/,iliw MME 1,,■■) EX2 nil x11 ligallffilla 11111 111 WA NGTON S E EM . , IMIERFA ■ ►li 1141.,rig.w, , I I 1 I 9 tW. sl rws ILIMBIllgE-----iinr—,,izArm imainrildfill st m Has • •MIN ■■ rim �,1�, 111111111111 PORTL ND, OR 9 R OM - -- ELECTRICAL A- IIIM- IIIIIIIIIIIMIERji ROOM r " CI11sst RED + 3/4 CONDUIT FROM — NT I HT TAT TI N SENSOR I M3 ♦ - '��1 MENS ADJACE L G s Mo 0�. n11aIN _ I I TENANT-N.I.C. I I I TO L I GHTSTAT LIGHTING L - - - _ 1 9I ' 1111171E11 TOILET RM .........ril"'.' 1■...............AIM 111■1•111■.........■■OM dlil CONTROL PANEL IN ELECTRIC ROOM. .111 jii ' � MENS H&M - ;iii III !III.,Em ler 141474 1 1 !.. :Aggh■- timh, la . 47'1 MI ot 1111111iii 1 II 1 11 � . . _.■� EM�- Q'I r [i 1111=111 LP '-5 k ,GO 1 FE��lil � 111 III A „ A...._,/2 , , ,‘ ,_ . 91/, Aim Mir drartirdmit 1 .� r • .• • ii �1.= , AREA illiPir . .r , \ , . , - .�,.r,E ;t� .1.. I I M - , , .-,..,- ,, ,, , , . _ . MENS SALES is �'�'�� ��,,-.,■�� M1.. I 't -zety , ■I�r�m�iailil :�11I11�11a1:�11�a�W! Vi ■i....�_t LP3-13 � ''1 / i :.�.�m��a ` ��_l r___________— WOMEN'S EM a •* 0 a L P2--1 0 Q f >� TOILET RM ■■■�. .. '„,..))1 41 EX1 .■ �' � NL BOY Ip!i I LP3-14 PL3- 8 ■■ = LP3-17 d il l 'Pi a d NL �111111111111111' _ �� �� � ♦ ♦ i Illi "1111. l�'' i ii 10 3/4” COND .4;1 �� ,� MENS I • m A-41 1 MALL COMMON if� ,,� I CHILD I L I GHTSTAT OT I ON SENSE'- DENIM ;• I OPE, TO l-! 1,' UNDERW. + TO L I GHTST T LIGHTING r E pill . .... .. 1 B •W I AREA N.LC.il' CONTROL PA EL IN ����am; (" d _./���... Q m 'I' STAIRS 4 ELECTRIC R OM.X EM NL NL • NL"EM 4,___________„„ __II E H B K 2 BOYS II 11__ _ _________________________ ._..�_, , �� CONSULTANTS, LTD ►�1►�1►��►��►��I►Z� X1 ►Z�►�I►Z�►��►�1►Z� '' a i r.; �� ,�_. d d Mechanical & Electrical Design Services �� BABIES ' ..—►,':�•, a--SI UNDERW. + ■ M •a a Q ( < .IEM NL L ' 1111,',�,' � EM ACC. I '`�... ; g. 171 Chdrrin Cross Drive S. In II Suite 1 B■ EX1 Westerville, Ohio 43081 1 614.882.1199 I �„ Q d d d •Q NL FAX 614,882,1857 NL NL NL NL .,__ ;____ gimbal!IM 111 ••EM 4- Y ♦hIII! !! h;:III:I'_ & ._IMuImI.umuum.imi_I II ��I i ~�`� d .■i d Gratings and irilten materiel appearing herein constitute original 11' `II111111:111 lJ • • E NLI 6 6 1 and unpublished 'ark of the Architect and may not be duplicated, III tz d • • t ` r ased or disclosed 'ithoot >rrilten consent of the Architect 0 11 I� - _ _ c�fdBN ARCHITECT 2010 1�� M ==. -- _, 1`I GIRLS •1 ANL— � �"■`' — --- DIV. B 0 A 0 C Id a a a - d WAI I �'� -ii EM • • • ■■ EM p ,1 I�' � � ' it I N . D 0 I!NL NL �'"1`� _ � _ I 05/28/10 100% SET T T T T T �► ��� ■�s '"- T T T T " .�'' T ��► .._,��..,, �� �� ►_.►`4►_.►�∎►_roz.►��►�.►►� �..� i w i.i■�■n ��►w�►_�1►.►�►.1rerA►El1►_eeiZ.,���i■II 11i. m l i 1� --MOOMMIXIMIN1===.111■MMMG-=11■11MMMW: •• '- - — -- 36 05/28/10 VT PACKAGE " '111111111 3/4" CONDUIT FROM -�__.,_,� tV DOWN TO STA I R 07/02/10 100% COMPLETE SET LIGHTSTAT MOTION SENOR N yNDER + LIGHTS ON 1ST TO L 1 GHTSTAT L I GHT I N �cgl. LEVEL. 07/28/10 LANDLORD SET • CONTROL PANEL I N ADJACENT 08/13/10 PERMIT/BID SET ELECTRIC ROOM. TENANT..-N,LC. NOTE SEE SHEET "E0. 1 " FOR LIGHTING CODED NOTES AND LIGHTING GENERAL NOTES, NOTE IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL n BRANCH CIRCUITS BETWEEN PHASES li T s REGARDLESS OF THE CIRCUIT SHOWN. a f O i j ALL WIRING MUST BE IN CONDUIT 4--- y -I- EMT or RIGID U k FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK AND AS THE FINAL CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, II _ MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE I; ;! SIZE TO RECESSED FIXTURES, MOTORS AND Project No. 44122/10038 11 !! ELECTRICAL EQUIPMENT THAT MAY GENERATE me II VIBRATION THROUGH THE CONDUIT SYSTEM. 1 Jill Scott AS NOTED , I' it �'' NOTE i I Dro•aBy: REK I i THE ELECTRICAL CONTRACTOR SHALL VERIFY , it �� EXISTING CONDITIONS TO INSURE THAT THE NEW 'I 1; Ii I WORK WILL FIT INTO THE EXISTING STRUCTURE IN I' I , i THE MANNER INTENDED AND SHOWN ON THE B. DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT N A2O1O Jobs\10038\US220E21bdug I ARE CONTRARY TO THOSE ON THE DRAWINGS, THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE "H &o n M" CONSTRUCTION MANAGER PRIOR TO FABRICATION Droving No. !Z OR PERFORMING ANY WORK IN THE AREA INVOLVING ri DIFFERENCES. NOTIFICATIONSHALL BE IN THE . i \''--T1=� ELECTRICAL FORM OF A DRAWING OR SKETCH INDICATING FIELD LIGHTING PLAN MEASUREMENTS AND NOTES RELATED TO THE AREA. MEZZANINE LEVEL 1/$"=114' ELECTRICAL LIGHTING PLAN - MEZZANINE LEVEL _ i Ealb ___. 0 • EE • DD • BB • AA • 0 0 0 7Vall4 1 l 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ADJACENT 1 I I TENANT-N.LC. 1 I I US220 I I I ,_I _ _ _1 _ _I _, I 1 I WASHINGTONSQUARE ____ _ ____ ___ ____ ____ _ _ - --I • 9685 S.W. Weilfton &Nero I I SATE HOB 1 1 I I I 1 o Po OR 917228 I I , I DISPLAY 0- 0- 0- 0- 0- 0- G7 A I I ,- .- .1 ;; LAD, r'''�! G c " ` EVERYDAY v WINDOW #1 CLAD RED I I I DIV. BLACK I LAD. 1 / , _ -= ■n — — �— — EVERYDAY:4 i — -- — — A — _ — 38 a =�==ii=:=_:__--__—_ �!!�1�—_- _ _ mill — -— 1 EVERYDAY_(!���lll — a — - -- "� G III- 1I LP1-9 0 / 1 I LAD. I I I I c t Pm RED DENIM , I a il 1 � I Iii ` /c� c� c� c� c W•ME S r. LP2-4 I. - G SALES . : G Pi ' MACHINE G I-' -� -� -� -� 1 t ROOM _. — --.:!I 11 : , I 1; .: \ / I I _- I ,I 0 e G I 1 LP1-5 , /I SA \ — —'- 0 9 LAD, i . - ., . . G EVERYDAY / t l._ 1 L P 1-1 i __ _ -' \ / _ + - G O N j MALL COMMON (;;:■, 4,: : ' '': ' I I DN. RED I /1\ - I AREA - N.LC. ,t , ' r r FITTING ca -0 - -c� -c� _t T '' VE ROOMS IU1I11L , 1r INM • / i I n `tttttntttt�`n I c �i 1 n\ J 1` I II o WOMENS LP1-7 �! D I 1 I SALES AREA ., ... n 0111 Ed 1 • I CI) ,. _. Milli — 1— si�J — .`�- T pillri, -/— \ ----J --R1 — 1 1 _ If_ LAD. LO.G.G. I I I G 1 1 I _ _ _ _ _ _ I ` 0 LP2-2 • G�_ D __ rill I G c� c� c� c1 c� c7 D '• • / 4. N ' I II I 1 1 s :s AREA D /'LP1-3 D D s 8 I 1► c i \ ' H B K J FITTING I G WOMENS I , , I I . I LAD. MODERN ( LAD. MODERN a' ROOMS SALES AREA •IS'. ACC. + II • / CLASS \ CONSULTANTS,TS LTD r - I := — -�J It LAD. LO.G.G. UNDERW. LAD. ACC. , ,_�, �, � a .g 0 ii 0 Mechanical & Electrical Design Services cc VI G DISPLAY II I �D• , r I. 2l WINDOW #2 171 Charring Cross Drive S. o I II UNDERW. r —'� site 1e I c� �� 0 c� c� • '► c� •uuiiuu•ca , iii )® a 43081 cc _ �I � WeervilleOn — I /[- �, �, 16 1 ----— a 614.882.1199 FAX 614,882,1857 Ilk Ailk , STAIRS • .. _____ 7 min ri..• id,..-.....4.... I . 1,,,i,,..... . _I_ _ _ _ _,., _ _ _ . --ip. _ _ .. _ :: _ _ 36 1 I I I I I I 1 Drawings and written material appearing herein conslilule original and unpublished work of the Architect and may not be duplicated, ADJACENT used or disclosed without written consent of the Architect TENANT-REC. c AIBH ARCHITECT - 2010 QAOC No. Date Issue NOTE 05/28/10 100% SET SEE SHEET "E0. 1 " FOR LIGHTING CODED 05/28/10 VT PACKAGE NOTES AND LIGHTING GENERAL NOTES. 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET NOTE 08/13/10 PERMIT/BID SET IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN PHASES REGARDLESS OF THE CIRCUIT SHOWN. ALL WIRING MUST BE IN CONDUIT EMT or RIGID FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK AND AS THE FINAL CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE SIZE TO RECESSED FIXTURES, MOTORS AND ELECTRICAL EQUIPMENT THAT MAY GENERATE VIBRATION THROUGH THE CONDUIT SYSTEM. NOTE . THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW IIIIIIII WORK WILL FIT INTO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE Project No. 44122/10038 DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT MI ARE CONTRARY TO THOSE ON THE DRAWINGS, THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE "H & Scott AS NOTED M" CONSTRUCTION MANAGER PRIOR TO FABRICATION MIN OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATIONSHALL BE IN THE Drowsily: REK FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. I I' N J:\2010 dolw1\100311\US220E22o.deq ii 9 Droning No. R V.1 (1) ELECTRICAL MONOPOINT VERITY ALL CONDITIONS IN FIELD PRIOR TO BIDS . LIGHTING PLAN FIRST LEVEL 1 4 1 ELECTRICAL MON OPOINT LIGHTING PLAN — FIRST LEVEL 1/8"4-O' 1 E2 • 2a 0 VERIFY ALL CONDITIONS IN FIELD • RIOR TO BIDS . "tilli PROCESSING AREA • • 69 0 DD BB AA 0 0 DECO II AREA _ _ US220 .., _ _ HARDWARE WASHINGTON SQUARE LAN ROOM ELECTRICAL S.W. W ashington Seism ROOM • I I I I I I I H SUITE HMI (../ X POFITLAND. OFt 97223 ADMIN JAN CLAM RED ROOM ADJACENT I I I I TENANT-N.I.C. I I I I L _ _ _ _ — III T MEN'S I I TOILET RM — — — — — — — — — — — — MTG/SEC ice i� ���ai i I ROOM al ������:� �— --- -- — 'L---ii_— �' I MENS AN&M I I� • G WOMEN'S F Ili! I. MENS LO.G.G. LP 1-21 I I ■ OILET RM — I �_ _ _ �_ _ _ III ' 1■11 �� — 1ii11 1■1/ L 4� — — ��iv at LP1 23 I II a 11 l'''' ua re I LOUNGE�1 BOYS I ..=� I� I 1.'... I ( .,^ . �!�!� MENS SALES �!� MENS SALES I ;4 a . gt(7,761,4,4 III HALLWAY Inumannumm I AREA mmmommomm 1:1■••••■•■••••••■•NENNEENNiii:11241111:121 G G - i IF im..........i-- - --- - LP1-11 , to N E1 it it IN teems i1 I I BOYS I E ..J�..1....�� _ ■ ► G G G G F �! D I STAIRS III I o IA G G c G ji tTTING �I Ir' iuiiiuir OP N O i :( I�I MENS. I Ii OOMS BE '►W il I'�� �� ( �' �' DENIM MAREA - N.I.C. !I II �I �. e G G • BOYS T t 11 III CHILD H B K 41111 UNDERW. + 0 I ►��►��►�� ACC. ►��►��►��►Z�►�r►�� ii ■ �: — — LP1-13 — — I — - -_ _ — — -� Ni Eli_., ♦ CONSULTANTS, LTD ►�4►Z�► ►T.►►:,�►►:� ►►`1►��►T�1∎MARTI►� J ` , Mechanical & Electricol Design Services I r CHILD ---I..., .w.. • 9 , , 1.11 UNDERW. + BABIES L P 1-19 ACC. - - _7) 171 Charring Cross Drive S. -ca -c, -c, -c) -c, -c, 0 _ - - - Suite 18 g 11] 4.- 11 Westerville, Ohio 43081 G I 614.882.1199 1 to 9)ill`I I G I I ix-WE--+ I I PG FAX 614,8$2,1$57 0 0 mi� � II , I DIY. BLUE.1111�� MENS MENS 11011 I I Bullrings and vrilten material appearing herein constitute original —` 1'i UNDERW. + 'R' UNDERW. + IIIjhllIl and un ublished cork of the Architect and may nat be duplicated, G I "I hill I ACC. I �. _ _�� I p M"" G I ill �- I used or disclosed without written consent of the Architect 1111 II • 111 �,I�I I��.�m���M��■ c(�MBH ARCHITECT - 2010 111 ill I I I GIRLS I I : 0cDot; Issue 7 Al III I��► III I ..�.� I Li : ii= _ _ i; ( /28jT T T ► T T �� T T. MA= 3 I I ►.•►_�►_•►_•►_�►_•►�..►_� ;, �. .�I.u.��■.1 36 05/28/10 VT PACKAGE 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET ADJACENT 08/13/10 PERMIT/BID SET TENANT-N.LC. NOTE SEE SHEET "E0. 1 " FOR LIGHTING CODED NOTES AND LIGHTING GENERAL NOTES. NOTE IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN PHASES n REGARDLESS OF THE CIRCUIT SHOWN. -r A. QCs ALL WIRING MUST BE IN CONDUIT. ) 1 �' EMT or RIGID 1 I- FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK AND AS THE FINAL _ CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE SIZE TO RECESSED FIXTURES, MOTORS AND I 1 ELECTRICAL EQUIPMENT THAT MAY GENERATE Project No. 44122/10038 f VIBRATION THROUGH THE CONDUIT SYSTEM. Score AS NOTED ■ "'o11 MI i � E ; , THE ELECTRICAL CONTRACTOR SHALL VERIFY Drowsily: REK l ; EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT INTO THE EXISTING STRUCTURE IN I ' I THE MANNER INTENDED AND SHOWN ON THE I . DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT N J:\2010,Iob,�\10038\USZZ0EY2bd■q E I ARE CONTRARY TO THOSE ON THE DRAWINGS, THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE "H & iii o M" CONSTRUCTION MANAGER PRIOR TO FABRICATION Droving No n OR PERFORMING ANY WORK IN THE AREA INVOLVING (ID 8 D I F F E R E N C E S. NOT I F I CAT I ONSHALL BE I N THE ELECTRICAL MONOPOINT H FORM OF A DRAWING OR SKETCH INDICATING FIELD LIGHTING PLAN MEASUREMENTS AND NOTES RELATED TO THE AREA. • MEZZANINE LEVEL 1 4 L g 1/13$0-Ox 1 v ELECTRICAL MONOPOINT LIGHTING PLAN - MEZZANINE LEVEL _ E 2 . 2 b 0 • eil • DD BB • AA • 0 • 0 1 I I 1 I I 1 1 1 I 1 ADJACENT I ( I I I TENANT-N.I.C. I I I tj,I I _ _ _ _I _ _ _ – _ _ _ _ _I _ I _ _ _ _ 1 WASHINGTON SQUARE ■ �.� �` ■ -0- ■ 01• 1, MI _ _ I NI fit 9686 W. „ , / SUITE Hob I li1 I LAD. I DISPLAY II I I EVERYDAY EVERYDAY , EVERYDAY / WINDOW1 PORTLAND, OR 97223 —�' i•■■�i- - - „ii- -- - - - i■�!�ili�n l - - multi - H i* �i - :■7��1i� -- �1' — — — 3 8 -- tjI ��=i _ —DN. BLACK c�� — � II - /IJ �_� ��___�_�_i ,, ._ 111 III \ / Y I ELEV LP1-4 DNr RED I LP1-12 I I LP1-20 LAD • 4 LP1-42 r—�iit1 1 • DENIM ■iiri WOMENS L P 1-14 =- I \ I • IllEJ • , / • MACHINE l3 L3 13 13 L3 L3 1;3 L - 6 ROOM I I I _�____.��..–_---_-._._- -ir-- —__._—. .___ I , / I :1F:11 8 � somomminagaromm■ ma WOMENS _ _ ;;7/7 q I MI IF i I I SALES AREA I ;, \ I :.: • o \\ /I i I I / ., L+9Q MALL COMMON if� , DIV. RED I — — /I`� — — "' �� ( AREA - NJ.C. EVERYDAY n J o i ' FITTING , , , ,, _ I ROOMS r • / DIV. = .CK \ WOMENS IF SALES AREA I I I \ rI � LP1-6 •— I I gle-.L.7 I el 1 ill Did� — — -- -- or: ■� J J I / \ r CD ', , I I I I I I I , ; I • r II I LAD. LO.G.G. , n 6 I iii W!, E `' 111 Ei I..1 I ,� I I I• ml i I I , FITTING DN. ACC. + LAD. � LAD. MODERN ROOMS S;. S ' UNDERW. LAD. ACC. MODERN / CLASS LAD. L.OG.G. 1 I III i 111 DISPLAY :_ III 11H1 i�i� Iii I I \ WINDOW #2 CONSULTANTS, LTD I I I Iui i ;; I Mechonicol & Electrical Design Services II Y o _ 'II UNDERW. I w I I '► LP1-8 S S f liI 'I___Ill Ilf\lig\ I 171 Charring Cross Drive S0 , m S- S ' I -- __– = '�" Westerville, Ohio 43081 alma 0 I I M_ t 1 I i kl 4'T Ili ,I st4.ss2.11SS simamomemilmax. r. � �—�" I FAX 814,$82,1857 IM trimmilisp alpgrii. II ... ..1-.711..---- 1-----1.--,TA-..;..---. . .---(-16===.1.2mok- -- I I I I I I _ Orarings and written material appearing herein constitute original LP1-10 ADJACENT end unpublished work of the Architect and may not be duplicated, TENANT-N.LC. used or disclosed without written consent of the Architect c@l BH ARCHITECT - 2010 OAOC NOTE No. Dote Issue SEE SHEET "E0. 1 " FOR L I GHT I NG CODED 05/28/10 100 SET NOTES AND L I GHT I NG GENERAL NOTES. 05/28/10 VT PACKAGE 07/02/10 100% COMPLETE SET NOTE 07/28/10 LANDLORD SET I T I S THE ELECTRICAL CONTRACTOR'S 08/13/10 PERMIT/BID SET RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN PHASES REGARDLESS OF THE CIRCUIT SHOWN, • ALL WIRING MUST BE IN CONDUIT EMT or RIGID FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK AND AS THE FINAL CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE SIZE TO RECESSED FIXTURES, MOTORS AND ELECTRICAL EQUIPMENT THAT MAY GENERATE VIBRATION THROUGH THE CONDUIT SYSTEM, NOTE THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT INTO THE EXISTING STRUCTURE IN NM THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT Project No. 44122/10038 ARE CONTRARY TO THOSE ON THE DRAWINGS, THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE "H & mil M" CONSTRUCTION MANAGER PRIOR TO FABRICATION Scale AS NOTED OR PERFORMING ANY WORK IN THE AREA INVOLVING MI DIFFERENCES. NOTIFICATIONSHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD OroinBy: REK MEASUREMENTS AND NOTES RELATED TO THE AREA. 1 N J:\2010 Jobs\10038\US220E23a.d.g 6 I 11 O Droving No. li N VII ELECTRICAL COVE — VERIFY ALL CONDITIONS IN FIELD PRIOR TO BIDS. LIGHTING PLAN FIRST LEVEL I 1 ELECTRICAL COVE/CABINET LIGHTING PLAN - FIRST LEVEL _ i E 2 i 3 a v ____ VERIFY ALL N CU ®ITI® ISIS IN FIELD PRIOR 1-(J BIDS . 7//111 PROCESSING AREA 0 DD BB AA Li CD DECO 0 AREA HARDWARE - 1 US220 LAN ELECTRICAL WASHINGTON SQUARE ROOM ROOM I I I I i I I H 96N SW. Square (A X 8UITE HOS poRruoix ADMIN JAN OR 91T ROOM I ADJACENT CLAD RED I I I TENANT-N.I.C. I I I I 0 I EN'S TOILET RM — — — — — — — —' — - — — 1�,���,�—a.._u__,_I MTG/SEC o, •-------- , ROOM . �i��©I M`���r,�—� I _— -►� I I � ��..r...��L L I �1-36 I t II di MENS H&M WOMEN'S III MAN I qi MENS LO.G.G,TOILET RM I !. I— — - . _ — — — " — — — El- — — — :: _ .v, �, iii;, Id LOUNGE I I l f---- iii ,, _ • • i �" it fill I I I . • I I =� I r�iisiii pm. I • HALLWAY BOYS MENS SALES L 2 L 1 L P 1-34 MENS SALES x ,LL Y III 1;1 II A AREA 'c ? ■■■■■■■■■■■■ �.rii� n . LP1-32 f I . LP1-22 _w_: 'MUM •_. I I BOYS, I �r M. ; PEI u.r r. I I how- al',... IFF 1 KIDS/BABY STAIRS �� SALES AREA I I I 1 _1 A iipiiiiiiiir 1 1� .�.' MENS I I OPE TO MALL COMMON j `� I c �► I DENIM - `I BE •W I AREA - N.LC. UNDERW. + �' BOYS I 1 LP1-39/41 MI ► FL...A . 1111,..7.:,-........-- --- -vim ' w.- .�.- I� ... .. ...; , Alimr_ JUNCTION BOX FOR BOXWALL LOW CONSULTANTS, LTD VOLTAGE TRANSFORMERS. COORD I NATE Mechanical & Electrical Design Services BABIES EXACT QUANTITIES OF TRANSFORMERS 1 �I + AND LOCATIONS WITH MILLWORK SHOP rd CHILD DRAWINGS, ARCHITECT AND H&M 171 Charring Cross Drive S. UNDERW, + A • I CONSTRUCTION MANAGER I N FIELD PRIOR Suite 1B Westerville, ACC, ( I I I I I TO STARTING WORK. ELECTRICAL Ohio 43081 L2 Li CONTRACTOR I S TO MAKE ALL FINAL 614.882.1199 ��� � � �= HIGH AND LOW VOLATGE CONNECTIONS. FAX 614,882,1857 III KIDS/BABY i III M I SALES AREA `,. MENS 111 + NS ,I DIV. BLUE + L P 1-30`� UNDERW. AR I:I CC.�II I I `� I� I MENS , ACC. i r I Drawings and written moleriol appearing herein constitute original II, . UNDERW. + i I and unpublished work of the Architect and may not be duplicated, j� `� I! �� used or disclosed without written consent of the Architect " GIRLS ♦ IP �i LP1-24 BF,i ,; ,i, ■r■u:i■■.�mar' CNBH ARCHITECT - 2014 il GIRLS `1 1.1 1� ( L P 1 28 Q A a C : 11 !!� rl . _iHHHIHi!!'r;i. lH I _ _ _ ilk---- ■' -- — __ 1 No. Dote Issue .� I I i i.a�a�ia�c� ,_,►�. ►� „ ,.,�►��I �4►�.�I — ►� 0 2 10 1009' SET 05/28/10 VT PACKAGE LP1-26 07/02/10 100% COMPLETE SET ADJACENT 07/28/10 LANDLORD SET ELECTRICAL CONTRACTOR I S TO TENANT-N.I.C. 08/13/10 PERMIT/BID SET FURNISH AND INSTALL A SINGLE RECEPTACLE I N WALL BEHIND POP—OUT NOTE WALL CABINETS AT EACH POWER CONNECTION END TO CONNECT CABINET " • LIGHTING POWER CORD INTO LOCATE SEE SHEET "E0. 1 FOR LIGHTING CODED RECEPTACLE AT 48" AFF (TYPICAL ALL NOTES AND LIGHTING GENERAL NOTES. CABINETS). NOTE IT IS THE ELECTRICAL CONTRACTOR'S —, RESPONSIBILITY TO PROPERLY BALANCE ALL n , BRANCH CIRCUITS BETWEEN PHASES REGARDLESS OF THE CIRCUIT SHOWN. s 0 ° ALL WIRING MUST BE IN CONDUIT f o 14 ,f .� EMT or RIGID FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK AND AS THE FINAL L CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, ( • MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE iiii, ; j 1 SIZE TO RECESSED FIXTURES, MOTORS AND . I 1 . ELECTRICAL EQUIPMENT THAT MAY GENERATE Project No. 44122/10038 1 ■ VIBRATION THROUGH THE CONDUIT SYSTEM. --.141 S c o I e AS NOTED _,F NOTE ' THE ELECTRICAL CONTRACTOR SHALL VERIFY Drowsily: REK 1 EXISTING CONDITIONS TO INSURE THAT THE NEW , � IL WORK WILL FIT INTO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ,' 1 — ARE CONTRARY TO THOSE ON THE DRAWINGS, THE N 4:\2010 Jobs\10035\uS220E23bdp ELECTRICAL CONTRACTOR SHALL NOTIFY THE "H & M" CONSTRUCTION MANAGER PRIOR TO FABRICATION 6 _ n OR PERFORMING ANY WORK IN THE AREA INVOLVING Droving No. E ri DIFFERENCES. NOTIFICATIONSHALL BE IN THE (1) c.i. FORM OF A DRAWING OR SKETCH INDICATING FIELD ELECTRICAL COVE MEASUREMENTS AND NOTES RELATED TO THE AREA, LIGHTING PLAN - c MEZZANINE LEVEL I r< ELECTRICAL COVE/CABINET LIGHTING PLAN MEZZANINE LEVEL 1i8*"1�-0* 1 . - E2.3b VERIFY ALL CONDITIONS IN FIELD PRIOR TO BIDS . FP DD BB • AA • 0 0 0 7/11/411/ I I i • I I I I I 4 I I I I 1 1 US220 I ADJACENT WASHINGTON SQUARE i I I I TENANT-NJ.C., I I LP2-3 9585 S.W. Washington Square 0 © © A © SUITE H08 I _ _ _ _ 1 PORTLAND, OR 97223 B-2 ELECTRICAL CONTRACTOR I S II' j=_=� _����—'_i-�L �� SF CLASS: RED TO FURNISH AND INSTALL �IIII j 0,4111111! IP I' �", 1i I 111 Airk I INTERCONNECT WIRING r M BETWEEN DS-1 AND ACCU-1 AS 18 RTU-2 rnIIpII€3o i i :: 1 DISPLAY REQUIRED BY EQUIPMENT O IIII I I I I WINDOW #1 E3.1 a LAD.AO, I LAD• I ELEVATOR • -- - --- III MI L:: I B EVERYDAY EVERYDAY, I ( \ EVERYDAY / I i _ I----_- -----._ - II— MINN -- ---'►T� _L _ ' -- u I I n■ i i� I F �,._, III! IIUI I� 111 ; I , -i c I� 1 I WOMENS I I I I i B-1 SFall 1 L D • IV. RED SALES AREA I �, 1 I ;. II 1 f . m=w__ I. `eta I DENIM ■�• ��� I 1 ` -_. - - 4 � MACHINE i � � ,'44 II 1 ROOM ESCAL. •R PIT " B-4 /A_16 i 4 Apdh========4111.m. \ / . .4 :ib ii I WOMENS s 1 v it .. ,......., . I SALES AREA I -\ 1- --:; ( ;; ztD) 3 "" V : 1 ! - - -T----) 1 .• i. r S mi DS .1 \\ // LP2-1 ,. -� - - / .i. LAD. MALL COMMON 1111/ I ,/,',N, T .. ... EVERYDAY 1 a N iD„ AREA - WC.iii DIV. RED ' IIIIIIII- c+�VE I o 1 / \ F PItTING � , 5 6 ROOMS L - - / _ , ___ 414 M111111111111110 ig) II 11 DIV.CI R • 1 141,,, 0 . r 0 . 1 GI .2 S_n _ — 1.— - �..�����1 ==�'1 _ — Mill ._ II!!l1i11 .._ - Iii. iil talk IN 1--- -- •� WOMENS O FIRE ALARM SYSTEM NOTE ' - SALES AREA / \ i I I I I KI I I 11 ELECTRICAL CONTRACTOR IS TO CONTACT LYNDE•LAD. LO.G.G. ! JOHNSON OF SIEMENS BUILDING TECHNOLOGIES, INC I AT (503) 234-9995 FOR A FIRE ALARM SYSTEM H B K I limill W�"M N I WITHIN TENANT SPACE IN FIELD PRIOR TO BID.I {� I SAL: A ' „ / S SIEMENS WILL BE RESPONSIBLE FOR NECESSARY FIRE LT FITTING ! I �It ALARM DESIGN DOCUMENTS WITH ENGINEERING SEAL CCJNSULTASJT'S,RooMS A Fi / \ —24 Mechanical do Electrical Design Services I ( i I ;; . MODERN PERMIT DOCUMENTS AND INSTALLATION AT THIS ®VVT-3 I WOM: • , I I LAD. MODERN I I p ALE ' . DIV. ACC. + CLASS ELECTRICAL CONTRACTOR'S EXPENSE. INCLUDE ALL / , COSTS IN BID. 54 AFT CLASS / 171 Charring Cross Drive S. © VVT LAD. LO.G.G. I ill UNDERW. Oak E4.3 ,111 I DISPLAY ,COSTS Suite 1B Westerville, Ohio 43081 I I•�� I' 1 ;; / \ o . — :� "I I tl '�� 614.882.1199 "-- --."..7 lb 1:1 I 1(D) w=—'M ® I I I I CASH WRAP 1 I I y WINDOW #2.. ... 11111011111111111111 NB NI FAX 614,882,1857 c) B-6 tc. I IILAD ACC II! - - 6 Oil I LAD. iili: 1i g — s — — — ---- J v , UNDERW. 110 i��T�T■■�� I �, 'iIh�i° �� sFrlr, . �.��!, © (TYP) and unpublished and written ; IeOrein costule aril I 6” » i� �11 a 6 LP2-5 11 11i � . and unpublished ark al Archilecl and may not be duplicated, �'r'[ 1 1 ".,�tll�._ it g1 _ _ . Ii �� , 1 (TYP) used or disclosed rilhout written consent of the Architect IN I I ,I, III 1111111111111111111111 � IN In �� e N ARCHITECT — 2010 I I© : RTU-1 wig Vii NOTE 0110C ADJACENT RTU-3 SEE SHEET "E3.4" FOR POWER CODED TENANT-N,LC. NOTES AND ELECTRICAL GENERAL No. Dote Issue NOTES. 05/28/10 100% SET 05/28/10 VT PACKAGE 07/02/10 100% COMPLETE SET NOTE 07/28/10 LANDLORD SET I T I S THE ELECTRICAL CONTRACTOR'S 08/13/10 PERMIT/BID SET RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN PHASES ELECTRICAL CONTRACTOR IS TO FURNISH ❑ ❑ REGARDLESS OF THE CIRCUIT SHOWN, AND INSTALL A BUSSMAN 60A-3P ELEVATOR I POWER MODULE FUSED SWITCH COMPLETE �- -J I WITH CONTROL TRANSFORMER, FIRE SAFETY I ill Kf , RI - INTERFACE RELAY, KEY TEST SWITCH, (l) III III III ELECTRICAL CONTRACTOR IS ALL WIRING MUST BE IN CONDUIT GREEN "ON" POWER LIGHT, NEUTRAL LUG, 2 All 4 TO FURNISH AND INSTALL A NO/NC AUXILIARY CONTACTORS AND FIRE ' SPERO "VWB30-41—G" EMT or RIGID VOLTAGE MONITORING RELAY FOR LOCATE RECEPTACLES B-18 I VAPOR—TIGHT LIGHT FIXTURE MONITORING SHUNT TRIP VOLTAGE IN A AND 30" ABOVE PIT B-16 � I WATT `LAMP,GUARD AND 100 FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR NEMA 1 ENCLOSURE. COORDINATE ALL FIRE FLOOR,- ALARM INTERFACES WITH FIRE ALARM , CONTRACTOR ALL R IN FIELD PRIOR TO ORDERING. %4% .B-14 CONNECTIONS INSIDE CASEWORK AND AS THE FINAL CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, ill I1It!.L.: `` C.l LOCATE LIGHT SWITCH AT MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE italltailli ■ �� WP, SIZE TO RECESSED FIXTURES, MOTORS AND � .., 48" ABOVE 1ST LEVEL ELECTRICAL CONTRACTOR IS ❑ - FLOOR. ELECTRICAL EQUIPMENT THAT MAY GENERATE TO FURNISH AND INSTALL A VIBRATION THROUGH THE CONDUIT SYSTEM. SPERO "VWB30-41—G" �!0 VAPOR—TIGHT LIGHT FIXTURE biE "�� WITH WIRE GUARD AND 100 WATT LAMP IN PIT. / 30A-1P LOCKABLE FUSED DISCONNECT COORDINATE EXACT LOCATION I B—20 SWITCH WITH LPN—RK 20 FUSE I N A NEMA NOTE WITH ESCALATOR INSTALLER ® i (1)D 1 ENCLOSURE FURNISHED AND INSTALLED IN FIELD. I GFI_ BY ELECTRICAL CONTRACTOR FOR ELEVATOR = CAB LIGHTING AND RECEPTACLE POWER. THE ELECTRICAL CONTRACTOR SHALL VERIFY B-22 EXISTING CONDITIONS TO INSURE THAT THE NEW ENV WORK WILL FIT INTO THE EXISTING STRUCTURE IN Project No. 44122/10038 I B-24 mom THE MANNER INTENDED AND SHOWN ON THE B—21 30A-1P LOCKABLE FUSED DISCONNECT DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT �• ' HP—26/28/30 SWITCH WITH LPN—RK 20 FUSE I N A NEMA ARE CONTRARY TO THOSE ON THE DRAWINGS, THE Scote AS NOTED �.� 1 ENCLOSURE FURNISHED AND INSTALLED GFI,:._ ELECTRICAL CONTRACTOR SHALL NOTIFY THE "H & All BY ELECTRICAL CONTRACTOR FOR M" CONSTRUCTION MANAGER PRIOR TO FABRICATION B_23 ELEVATOR OIL COOLER POWER. ELECTRICAL CONTRACTOR IS OR PERFORMING ANY WORK IN THE AREA INVOLVING DroinByr: REK TO FURNISH AND INSTALL DIFFERENCES. NOTIFICATIONSHALL BE IN THE GROUND FAULT DUPLEX ELEVATOR CONTROL PANEL BY OTHERS. FORM OF A DRAWING OR SKETCH INDICATING FIELD I RECEPTACLE IN PIT, ELECTRICAL CONTRACTOR IS TO PROVIDE MEASUREMENTS AND NOTES RELATED TO THE AREA. COORDINATE EXACT LOCATION POWER TO CONTROL PANEL AND TO ELEVATOR MOTOR AS DIRECTED BY J•�ZOtO �Ifl0t�2Z0E31a.d� k WITH ESCALATOR INSTALLER ELEVATOR INSTALLER IN FIELD. IN FIELD. I J$ 9 Drawing No. I 1 ESCALATOR ELECTRICAL PLANS ELEVATOR ELECTRICAL PLANS ELECTRICAL 3. 1/4"=1'-0" ITYP. OF 2) . 1/4"-1'-0" PLAN POWER FIRST LEVEL 1 ELECTRICAL POWER PLAN - FIRST LEVEL _ i E 3 1 i a . 111 II 40 VERIFY ALL CONDITIONS I . FIELD PRIOR TO BIDS . lilt/ PROCESSING AREA A-5/7 (SPLIT REC) L1GA-10 -- ► • DD BB AA 111 LAN Z DECO 0 0 0 ii ROOM z AREA A-28 FIRE ALARM SYSTEM NOTE "%, II► "' i ELECTRICAL A CONTRACTOR IS TO CONTACT LYNDE r.. ... JOHNSON OF SIEMENS BUILDING TECHNOLOGIES, INC 522. }A-1 0 11 11,p0 EF \/) Amk 1 I ( r E4.1 AT (503) 234-9995 FOR A FIRE ALARM SYSTEM WASHINGTON SQUARE HARDWARE • 36 AFF WITHIN TENANT SPACE I N FIELD PRIOR TO BID. A-17 ELECTRIC/LANI I I I I I I SIEMENS WILL BE RESPONSIBLE FOR NECESSARY FIRE 9585 S.W. Washington Square 0 �L tin WH-1 ELEC RM EF ALARM DESIGN DOCUMENTS WITH INSTALLATION ENGINEERING TH I THIS SEAL , g VVT _ _ PERMIT DOCUMENTS AND S LL , SUITE H08 411:> ADMIN �%! A-15 2 ELECTRICAL CONTRACTOR'S EXPENSE . INCLUDE ALL O I - ADJACENT COSTS IN BID. PORTLAND, OR 97223 1 ROOM E 4.1 TENANT N.I.C. iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii 1 p III �� CLASS: RED 1 @ VVT-2 ir ADMIN & MTGySECURTIY I I I I I I L _ _ — — A-4/6 ■ 10. A-8 HP-7/9/11 HP-13/15/17 A-13 �6__o wP \ ij� .'w _ 4'-�'' I MOUNT ABOVE / © Q 0' VVT-1 IF--- GFI CEILING - ■A -- -- — — — — — — �: I MEN'S © �������■�������,��■� DN. TO 1ST MTG/SEC 0 TOILET •' ', -- _-- — — — - ��►• '� FLR BUZZER ��,:,: I�.�u�I i�>:�a� .��1 r 1 ! ipAiiii, ROOM A— 4 HP-19/21/23 I I ! —.... .•�— -_,.. ' © (rn ROOM c�������� ` i'ji I v WO A 22. RTU 5 Ilr �I►■ _ MENS L O.G.G. ill111Fni • 1I! „ ,� 41111:110 I I! RTU—6 44 gil 4 I�11 1 0 I °ii:i1ii■ G �� '`' f I - - 1 I - -- - - — - 3� N E LOU G ,�► L J L 1 v I. '.----_-=_.-.----20-.------..--=.4.7-7...... H.H.LIPARH.1.4 '...a4.---=-.i-...:*......=4".. .-'7--;-ii111 ,w. CR'I� A-12 ��I �` ;�°� ... � -- 1 6" I I I I I I I it- IrC3 140" L _ _ •• ELEV �� B-8 �• RTU (RTU) -, - A-1 1 _1 M NS ALE MENS SALES l ;v A(1-eeid pa-1G HALLWAY 0 �� ,� B 0 •�. AR 3 �, � `� j■■■■■■■ - r ►�I Li 19 r t -mss' ` 7---411 air w- -- - PIIIIIIIkAll O .. E3.1b BOYS ._—�i1 i i�i�rii RTU 1 g RTU-4 4 rij: ' ESCALATOR PIT M N 4 0 , 0 KIDS/BABY ' ' E S 0 I.� `� III DENIM EF SALES AREA �� - �,:I1. ss� 1 4 � � _1 IIf ` _ ■ROOMS MM N il if ACLU I I CHILD I , - - ( HP-31/33/35 OPE TO I MALL AREA N.I.C. ILA 1 UNDERW, + �� HP-25/27/29 i BE *W 0 l� iii A 1 I `� BOYS 1T1 asiss.......! _ _ % I iii,.. H B K . 'J1111111110. — — v T '— f CONSULTANTS, LTD ► s'�►� ►�� I ii r i� im:N MMN if Mechanical do Electrical Design Services i" I I 400 ,.WINO Ilk E•NJ. MIN NC E3.1 b BABIES 1 0 i I RTU ESCALATOR PIT TU � I —.I DIV. =LUE + 6 suite 1e g wirirrall 1 '� 171 Charring Cross Drive S. I`I CHILD — RTU A' Westerville, Ohio 43081 614.882.1199 (" UNDERW. I I r' HP-1/3/5 I RTU I I I FAX 614.882.1857 W W sitiwiits ili 1 -A ACC. HP-37/39/41 SALES AREA A_g ►1 Ilfi ! L �© I) I DIV. BLUE. + „I 1�\ MENS — — — O E4,2 'III I ACC. Drawings and written material appearing herein constitute original I I GIRLv1� Iii UNDERW. + 110111 I I and unpublished rack of the Architect and may not be duplicated, �I I CASH WRAP �I/! or i los d without written consent of the Archilecl ! Al � . � . . �dilhallillip1!1,1 ! u s e d o d s c e A I n�� B-12 �►I. ' 1°11 c(JMBH ARCHITECT - 2010 ,1 X11►. ,I 1l►��Y•■rte �i■I■ 1111■Vii) I ,I � i MENS s" g I Q Q A 0 C 18 RTU-7 GIRLS ."� ' r 1 �, !! RS RI VI �: 1 UNDERW. + I N I s e 111, , ,/�I a. Dale s� I I j1)e ►��►,.....•�►�►70.7.—A►�. ►��.-::. : :—slam--— - ►..•1►• ►.•1►►_•1►mrl►.....►cii►m..R... X11- • —■.. .:aw; MEN EMI Ii P.=w■i 05/28/10 100% SET :: =.11••;,., 11=0“IMMI■1 MOM .. r. .....� .. .ti — `- 05/28/10 VT PACKAGE e Q 07/02/10 100% COMPLETE SET ADJACENT TENANT—N.I.C. NOTE N O T E 07/28/10 LANDLORD SET SEE SHEET "E3.4" FOR POWER CODED 08/13/10 PERMIT/BID SET NOTES AND ELECTRICAL GENERAL 30A-1P MANUAL MOTOR NOTES, STARTER, LESS OVERLOADS, FOR ESCALATOR LANDING LIGHTS. COORDINATE WIRING OF ESCALATOR LIGHTS WITH ESCALATOR NOTE INSTALLER IN FIELD. IT IS THE ELECTRICAL CONTRACTOR'S • ELECTRICAL CONTRACTOR IS RESPONSIBILITY TO PROPERLY BALANCE ALL 4 TO FURNISH AND INSTALL A BRANCH CIRCUITS BETWEEN PHASES 30A-3P FUSED DISCONNECT ELECTRICAL CONTRACTOR IS SPERO "VWB30-41—G" REGARDLESS OF THE CIRCUIT SHOWN. SWITCH WITH LPS—RK 20 FUSES TO FURNISH AND INSTALL VAPOR—TIGHT LIGHT FIXTURE FURNISHED AND INSTALLED BY GROUND FAULT DUPLEX WITH WIRE GUARD AND 100 ELECTRICAL CONTRACTOR FOR RECEPTACLE IN PIT. WATT LAMP IN PIT. ESCALATOR. COORDINATE COORDINATE EXACT LOCATION COORDINATE EXACT LOCATION WIRING WITH ESCALATOR WITH ESCALATOR INSTALLER WITH ESCALATOR INSTALLER ALL WIRING MUST BE IN CONDUIT INSTALLER IN FIELD. IN FIELD. IN FIELD.-------_... EMT or RIGID ESCALATOR FDS #2 — 1 B-11 FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR B-19 ' Pj B-17 CONNECTIONS INSIDE CASEWORK AND AS THE FINAL CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH,O . Gil ELECTRICAL CONTRACTOR IS GFI__ MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE 40.....--.07):] `� TO FURNISH AND INSTALL SIZE TO RECESSED FIXTURES, MOTORS AND B-17 GROUND FAULT DUPLEX I B-19 ELECTRICAL EQUIPMENT THAT MAY GENERATE —1 ---�-F—� I�� RECEPTACLE IN PIT. _ VIBRATION THROUGH THE CONDUIT SYSTEM SYSTEM. Project 44122/10038 B 5 — COORDINATE EXACT LOCATION ESCALATOR FDS #1 IIIIIIIII WITH ESCALATOR INSTALLER 30A-1P MANUAL MOTOR IN FIELD, STARTER, LESS OVERLOADS, ELECTRICAL CONTRACTOR IS TO 30A-3P FUSED DISCONNECT LANDING FURNISH AND INSTALL A SPERO SWITCH WITH LPS—RK 20 Seale AS NOTED FOR ESCALATOR L D G " FUSES FURNISHED AND LIGHTS. COORDINATE VW830-41—G VAPOR—TIGHT LIGHT INSTALLED BY ELECTRICAL NOTE WIRING OF ESCALATOR FIXTURE WITH WIRE GUARD AND 100 CONTRACTOR FOR ESCALATOR. Drowsily: REK LIGHTS WITH ESCALATOR WATT LAMP IN PIT. COORDINATE COORDINATE WIRING WITH THE ELECTRICAL CONTRACTOR SHALL VERIFY INSTALLER IN FIELD. EXACT LOCATION WITH ESCALATOR ESCALATOR INSTALLER IN EXISTING CONDITIONS TO INSURE THAT THE NEW INSTALLER IN FIELD. FIELD. WORK WILL FIT INTO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE IL : (' i \ ESCALATOR ELECTRICAL PLANS 2 ESCALATOR ELECTRICAL PLANS DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT .r.�o1O,lobs\t0038\t1S220E31bdrp ARE CONTRARY TO THOSE ON THE DRAWINGS, THE E3.1b 1/4":1'-0" 3.1b 1/4"=1'-O" ELECTRICAL CONTRACTOR SHALL NOTIFY THE "H & N M" CONSTRUCTION MANAGER PRIOR TO FABRICATION Droving No. i OR PERFORMING ANY WORK IN THE AREA INVOLVING N DIFFERENCES. NOT I F I CAT I ONSHALL BE I N THE ELECTRICAL FORM OF A DRAWING OR SKETCH INDICATING FIELD POWER PLAN MEASUREMENTS AND NOTES RELATED TO THE AREA. MEZZANINE LEVEL 1/8"=1'-0" i ELECTRICAL POWER PLAN - MEZZANINE LEVEL _ 1 E3 .1b • D® BB • AA -• 0 • SOUND SYSTEM INSTALLATION NOTES 1 . "M16-F" & "DS100-F" LOUDSPEAKERS TO BE MOUNTED AT LOCATIONS SHOWN. SPEAKER TO BE PITCHED AT 90' ANGLE DOWNWARD. ELECTRICAL CONTRACTOR TO PROVIDE ALL MOUNTING BOXES AND CONDUIT AS REQUIRED BY CODE. EXTEND 3/4" 2. "DS100-SE" LOUDSPEAKERS TO BE MOUNTED AT LOCATIONS SHOWN. CONDUIT UP TO SPEAKER TO BE INSTALL AT 9 FT. AND ANGLED DOWNWARD. SOUND RACK IN ( I I I ( C: fii: I ELECTRICAL CONTRACTOR TO PROVIDE ALL MOUNTING BOXES AND ELECTRICAL ROOM CONDUIT AS REQUIRED BY LOCAL CODE. (TYPICAL OF 4) . I I I I I I I I 3. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT AND SINGLE GANG US220 BOX AT DJ/SPEAKER JACK LOCATION. • ♦♦ ! ---____.._______ _________�__ ADJACENT 1" WASHINGTON SQUARE S- r_____ ...,,,,___�____i� EXTEND 1 CONDUIT 4. ELECTRICAL CONTRACTOR TO PROVIDE A QUADRAPLEX, 20 AMP I ••ri,_,________ TENANT-N�.C. OUTLET I N ELECTRIC ROOM FOR SOUND SYSTEM ELECTRONICS. •• �•�rI.__„............ ( I TO SECUR 1 TY I I • a``�.! •_____ I SYSTEM I N REFER TO ENLARGED ELECTRICAL ROOM PLAN ON SHEET E4. 1 . 9585 S.W. Washington Square $ `' ,,,, `-.+__u1_•_ '�•..,_�____ SECURITY ROOM. 5. ALL SPEAKER WIRE TO BE 16 AWG PLENUM RATED,. EXCEPT THE SUITE H08 �♦ �``•� I `�```••.�, I I `'`'�•�..,._� — -I — — — —� — — —� I — — — — 1 SPEAKER JACKS ARE TO BE 10 AWG PLENUM RATED. PORTLAND, OR 97223 •� •._ !I' �'�iii ��i �� �� � ' �� CLASS: RED ``� I ....1... I I �`�```�•..,, EVERYDAY Q�I ` 1 `. • `''• I �' ' \ / DISPLAY �. . I `..•, I I ( •`••.� I EVERYDAY Il ```•.,, o I I ` EVERYDAY / �- -vti ___ .....- �1-- —_ —�I�'Zii— — mil!--- —DIV. L11_'iil_ - — _j � — 1= 38 i— ♦ s., ■■rin" = it DIV BLACK . — . II ' '`•• '--J 1 1 • FC •.�` DN. RED`�� I I I `�►.�. I I I • 1 ` `� DENIM • ••.� SOUND SYSTEM SYMBOLS LEGEND \ E.EV ♦, I I •sir ��, .•,,�` �. r,,.. ^ .� . ❑ 0* v ' ' RACb WALL MOUNTED EQUIPMENT RACK — LOCATED IN ELECTRIC ROOM klft/- I I. rrr WOMENS fry' . '© 3a 49 \ lili ��, r r rr SALES AREA, ``.��� \ / ® DJ JACK (FOR USE WITH H&M DJ SYSTEM) • rr w I MACHINE i I EXTEND 1" CONDUIT `. I —_—.—.—_ _..___ —.�.— '`f.� I I ii : I ` � � � t �; SPEAKER JACK TO BE INSTALLED AT 12" AFF a' �J'- �� ROOM �, TO SECURITY ,, •% 1 \ / SYSTEM I N �� » `� LAD. � 1 M o '` EXTEND 1 CONDUIT . t ,� FLUSH MOUNTED M16 LOUDSPEAKER TAPPED AT 4 WATTS il I SECURITY ROOM. ♦ I •TO SECURITY �, ��.� ; AY ;; ft• -\ — sYSTEM IN I M I RfTY R , O DS100—F FLUSH MOUNTED LOUDSPEAKER TAPPED AT 100 WATTS SECU OOM. h'*'4r. _ .,.w ^h }4 - SALES AREA ' .. / ;, `.� à 1 MALL COMMON ® DS100—SE WALL MOUNTED LOUDSPEAKER TAPPED AT 100 WATTS I DN. RED — `� 0 N o AREA - N.LC. I i jr I /I\ I (a , •. I 18"II •'4. -` .1 120VAC, 20 AMP CIRCUIT, I .G. QUAD OUTLET, 18 AFF , i I � — ;�♦� .i i I- I ;;■ - I WOMENS i I I: `• / '' t I �''� DIV. : CK SALES AREA • S 1 ' S% rr. �1 n _ ,� --_— -- -------� _ _ - o .. rrr-rr Or A I ======Win■ I _-:�I _._ — I'%il I — — Ilia_ — _ 1.1111 — II:,'�'I - �.. _ NI -f-----1 0 ---f- I ICI ■ • � — EXTEND' 1° COI4DU I / ,��� ���� - - 4w I TO SECU R;I TY 1 I I I I � SYSTEM IN i �� • LAD. L.O.G.G. ; SECURITY ROOM. ••..._- . ) " i 0/. ` ❑ i I i ' viii �i� �� C' "".• � 1110 11-1 1 LAD. MODERN I ° �� '• I I fl Fla in er 0 RMS w I w ENS i cu CON�T�, LTD 2 t I 'AL S AREA Mechanicei & Electricol Design Services 4.)♦ I ..I r"' I I q •.•. C .+r.•• ( `"_._�,.r.' I I; LAD MODERN 0 rrr .,,+" r �♦ o�,,,,,r ..,,. .r LAD. ACC. / �:�. , . 9 t I 1 i� i DIV. ACC. + I DISPLAY t 71 Charring Cross Drive S. IS-O4t EXTEND 1 CONDUIT I I�� j I Westerville, ',� OMEN WINDOW #2 suite tB- TO SECURITY �I I'!I UNDERW. I'll • I ;; \ I 614.882.1199 ( - I LAD. Lo.G.G. I , t Ohio 43081 � 1 SYSTEM I N 3 Os MEAN I I, � ' I FAX 614,882,1857 Q `"`. SECURITY ROOM. M I g ```►``� =�- liA. ac I 1 I !► , p n I - I LAD. i I I U 6 l UNDERW.o , ,'� , I I STAIRS Ororrings and rrrilfen malarial appeoring herein cons(ilule originol Q MMIL 1I ,1 I and unpublished work of the Architect and may not he duplicated, — I — � ��1111111111—� l 1- ( _ 1 ,� (� , — _._ I — used or disclosed without Britten consent of the Architect .. — — — - _.._ 36 ©MBH ARCHITECT - 2010 I i I I I I I I 1111111111111111111111111.11111111111111111111111111 OAOC ADJACENT TENANT-N.LC. No. Dale Issue 05/28/10 100% SET 05/28/10 VT PACKAGE 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET 08/13/10 PERMIT/BID SET ALL WIRING MUST BE IN CONDUIT EMT or RIGID FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK AND AS THE FINAL CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE SIZE TO RECESSED FIXTURES, MOTORS AND ELECTRICAL EQUIPMENT THAT MAY GENERATE VIBRATION THROUGH THE CONDUIT SYSTEM. NOTE THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT INTO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE Project No. 44122/10038 ELECTRICAL CONTRACTOR SHALL NOTIFY THE "H & IIIIIIIII M" CONSTRUCTION MANAGER PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING Stole AS NOTED DIFFERENCES. NOTIFICATIONSHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. Drowsily: REK • I k NOTE N A2010 Jobs\10038\US220E32o.deg I. SEE SHEET E3.4 FOR SECURITY PLAN CODED ;; NOTES. Droving No. t47 (13) AUDIO PLAN/ VERIFY ALL CONDITIONS I FIELD ID S. SECURITY PLAN N FIRST LEVEL 1 1/8"4-0' i 1 AUDIO PLAN/SECURITY PLAN -• FIRST LEVEL . 2 a ■■ I I 11!iillrill4/1! VERIFY ALL CONDITIONS IN FIELD PRIOR TO BIDS . PR* G i On IIIIIIIIIIIIIrMMIIIIIIIIIIIIIIIIIIIIIII _ 411) SOUND SYSTEM INSTALLATION NOTES DD BB AA 1 . "M16—F" & "DS100—F" LOUDSPEAKERS TO BE MOUNTED AT LOCATIONS SHOWN. SPEAKER TO BE PITCHED AT 90' ANGLE DOWNWARD. ELECTRICAL CONTRACTOR TO PROVIDE ALL MOUNTING H -DWA'E O BOXES AND CONDUIT AS REQUIRED BY CODE . , US220 1Z° R,�� i � AUD f O RACK`:. SEE SHEEfi 2. "DS100—SE" LOUDSPEAKERS TO BE MOUNTED AT LOCATIONS SH WN.o ��� li �••• " 4 1" I SPEAKER TO BE INSTALL AT 9 FT . AND ANGLED DOWNWARD. AN WASHINGTON SQUARE© ��_—��, ��,- �,,, ■■ E FOR ADDI T ONAL ELECTRICAL CONTRACTOR TO PROVIDE ALL MOUNTING BOXES D , INFORMAT I OfV CONDUIT AS REQUIRED BY LOCAL CODE . 9585 SW. Washin on Square I I I I I I I a iiI _ _-RA�KI- • -- ------ 1------` 3. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT AND SINGLE GANG SUITE H08 H LECICL •...,��`�`�` BOX AT DJ/SPEAKER JACK LOCATION. PORTLAND, OR 97223 ADMIN __ ■■ ..,,� ROOM •�... 4. ELECTRICAL CONTRACTOR TO PROVIDE A QUADRAPLEX, 20 AMP — .'`.•.,.uI. OUTLET I N ELECTRIC ROOM FOR SOUND SYSTEM ELECTRONICS. CLASS: RED 'I .���- REFER TO ENLARGED ELECTRICAL ROOM PLAN ON SHEET E4 . 1 . eitami 1 •. ADJACENT mp MEN'S I 1' •. I TENANT-N.I.C, I I I I ,L_ - D/ I TOILET RM • 5. ALL SPEAKER WIRE TO BE 16 AWG PLENUM RATED, EXCEPT THE 11 —� SPEAKER JACKS ARE TO BE 10 AWG PLENUM RATED. W4-I, S. © . EXTEND 1 " CONDU 1 T `• — — — — — — — — — -- -- -- -- — TO SECURITY SYSTEM EXTEND 1 " CONDUIT �`•.� IN SECURITY ROOM. lallgr Ea ■ TO SECURITY SYSTEM �. —r— IN SECURITY E CUR I TY ROOM. `. �!■■■ � � ,. MROOMC 1.1 I 1 . I MENS LO.G.G. _I 011 —.41 I I I I WOMEN'S I gill , \ 2 ■•■■■■ A c I TOILET RM .. ryrrrrrrrrr�.■lip --------rr..rr / 4)'‘)r'- f�i�■�■■■■ I_E —� ::�_ 0 - `,�� LJ o. r'�rrr — u — ■ I — — _ — _.__— —_ r I • t 1�1 ■�l�I III ( •r • �'�1>`:� �� ■' � �� �■ �' ■ ■■'�,,■iii■ ©.� :.. ,,■m. L ilk■ ■■■■li■ a . 1 1 . 1 1 blt/7-?0(62 ���, BOYSn I f ■■�■■�=E■ rit1-1.71. '. I r I I ♦ MENS SALES I MENS SALES 11116111111.11111111111111111NMIMMEMIMMIIMINIA0 . , 40 0■1•"it 6 . e i Ilim r.,i.7—.2 0 EXTEND 1 CONDUIT 1 �•.� EXTEND 1" CONDUIT TO SECURITY SYSTEM �r �. ® R I TY Y T M •ter•. WW1 ■nor I N SECURITY ROOM. r Q . TO SECU S S E Imo' ---....____� *"*. I 1 N SECURITY ROOM. I BOYS I r -� I i STAIRS r , ir II l I KIDS/BABY r i r SALES AREA 1 : SITTING r TOM S I I i I J I r o OPE TO I MALL COMMON I r I BE , AREA - N.I.C. L MENS CHILD = I r DENIM UNDERW. + © BOYS ZEZEZ ZE;EZEZE i .A IIP1=.O 11771:7?:=_.1;E=1E=ZE 1, CC. ' 1 I I 1 1 ID ■ K H - � � _ _ _._. ...- - -- � - - CONSULTAN'IS, LTD Mechanical & Electrical Design Services I, ID w�•1 !�•J!� 1 EXTEND 1 CONDUIT ; EXTEND 1 " CONDUIT U BABIES TO SECURITY SYSTEM TO SECURITY SYSTEM I N SECURITY ROOM. �'•• 171 Charring Cross Drive S. I N SECURITY ROOM. I `"-r ' SOUND SYSTEM SYMBOLS LEGEND 5''''-r�,rrrr----r-rir----`.•� o i A' ♦ \`‘ 0 Suite vill @, Ohio 43081 Suite B CHILD r-i 614,882,1199 UNDERW. + I r I I I I I I tRAcla WALL MOUNTED EQUIPMENT RACK — LOCATED I N ELECTRIC ROOM FAX 614,882.1857 r _ _ L_J ACC. r ® ..rrrrrrrr r ....� -`-_'.�` , �.��s,,. •,.,,�i�� DJ JACK (FOR USE WITH H&M DJ SYSTEM) r KIDS/BABY ! , MENS boy M-E ' 'oV' SALES AREA `4 J UNDERW, + UNDERW, + ® SPEAKER JACK TO BE INSTALLED AT 12" AFF -- FA1 �L A £ Ate, , , DIV. BLUE. + Orovings one irilten moleriol appearing herein conslilute originol $- ,� },� FLUSH MOUNTED M16 LOUDSPEAKER TAPPED AT 4 WATTS and unpublished pork of the architect and mot not he duplicated, t I I �� I ��I / _ExTEND1" boNotiiT \ '� ( ACC. I I toten consent of the Architect �� TO SECURITY SYSTEM ,�� 111 O DS100—F FLUSH MOUNTED LOUDSPEAKER TAPPED AT 100 WATTS wriimumwrimmi � " c�hIBH ARCHITECT - 2010 lk • GIRLS MI (DI"' 1111: S E CUR I T" ROOM. i• ' l — DS100—SE WALL MOUNTED LOUDSPEAKER TAPPED AT 100 WATTS b n��.rr■ri■�:�■r��rl■����ll�. $ _g ���_ T — I 12OVAC, 20 AMP CIRCUIT, I .G, QUAD OUTLET , 18" AFF A �� 1 IG PI GIRLS, ' "I rn� Al , II a► STAIRS I No. Dole Issue I I I 1 I I ( 05/28/10 100% SET U .. — a. A ti — *J1 - 1 - - ., - - 36 05/28/10 VT PACKAGE 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET ADJACENT 08/13/10 PERMIT/BID SET TENANT-N.I.C. ALL WIRING MUST BE IN CONDUIT EMT or RIGID FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK AND AS THE FINAL CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, IIIIIIMMMMEMEMEMEM MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE SIZE TO RECESSED FIXTURES, MOTORS AND • ELECTRICAL EQUIPMENT THAT MAY GENERATE T VIBRATION THROUGH THE CONDUIT SYSTEM. ie I J. NOTE - Ili THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT INTO THE EXISTING STRUCTURE IN `� THE MANNER INTENDED AND SHOWN ON THE� DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT �H!�1 ARE CONTRARY TO THOSE ON THE DRAWINGS, THE Project No 44122/10038 ,_Fl_i ELECTRICAL CONTRACTOR SHALL NOTIFY THE "H & IIIIIIIII miH 1∎1 M" CONSTRUCTION MANAGER PRIOR TO FABRICATION mo! MIIIIIIIIIIIIIII'IMMUNE" OR PERFORMING ANY WORK IN THE AREA INVOLVING Scole AS NOTED MIIIMMMEI; ,_■' DIFFERENCES. NOTIFICATIONSHALL BE IN THE •111111111111111111!r="`• FORM OF A DRAWING OR SKETCH INDICATING FIELD �1i1���1' MEASUREMENTS AND NOTES RELATED TO THE AREA DrovoBy: REK ,�P Imo, 11111111111WI am; I!1111111111111 NOTE N J:A2010 josvtOO����.d I'1�! 1111111111111111 — SEE SHEET E3.4 FOR SECURITY PLAN CODED �. N NOTES. I III g No. ii n .1 rl VIP AUDIO PLAN/ SECURITY PLAN MEZZANINE LEVEL 1 _ , 8 1 AUDIO PLAN/SECURITY PLAN - MEZZANINE LEV EL i E 3 le 2 b _ AUDIO/SECURITY PLAN CODED NOTES POWER PLAN CODED NOTES ELECTRICAL GENERAL NOTES 7//1/ KIII: PROVIDE A JUNCTION BOX MOUNTED TO THE STRUCTURAL CEILING AND O 1 1/2"TELEPHONE SERVICE CONDUIT ABOVE CEILING OR TIGHT TO 1. FINAL CONNECTIONS TO ALL LAY-IN FIXTURES AND RECESSED PROVIDE A 3/4"CONDUIT WITH PULLWIRE FROM JUNCTION BOX TO THE STRUCTURE(WHEN IN OPEN CEILING AREAS) FOR H&M TELEPHONE SERVICE. INCANDESCENT FIXTURES IN LAY-IN CEILINGS ARE TO BE MADE WITH SECURITY PANEL FOR FUTURE SECURITY DEVICE. SECURITY DEVICES SUCH AS ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL CONDUIT WITH PULL GREENFIELD FLEXIBLE CONDUIT. GLASS BREAK SENSORS AND MOTION DETECTORS SHALL BE PROVIDED BY WIRE FROM LANDLORD'S ELECTRIC-TELEPHONE ROOM TO TELEPHONE THE SECURITY CONTRACTOR. BOARD IN LAN ROOM. BUSH BOTH CONDUIT ENDS. 2. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION KIII:: PROVIDE A JUNCTION BOX FOR SECURITY CAMERAS AND Al"CONDUIT OF LIGHT FIXTURE LAY-OUT. CONTRACTORS TO CORRELATE LOCATIONS OF DUPLEX OUTLET AND DATA JACK FOR EMPLOYEETIME CLOCK MOUNTED AT LIGHTING, SPEAKERS,AIR DIFFUSERS,GRILLES,AND THE LIKE,WITH et WITH PULLWIRE FROM JUNCTION BOX TO THE SECURITY OFFICE FOR 48"A.F.F. REFLECTED CEILING LAY-OUTS AS REQUIRED AND DIRECTED BY TH E FUTURE SECURITY CAMERAS. VERIFY EXACT LOCATION AND QUANTITY PRIOR TO BID. O MOUNT RECEPTACLE HORIZONTAL AT 6"A.F.F.COORDINATE LOCATION IN ARCHITECT. 3 JUNCTION BOX AND QUAD OUTLET FOR POWER TO SECURITY PANEL. (ALSO BASE OF COLUMN WITH MIRROR INSTALLATION. INSTALL ON NON- 3. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND/OR ROOM FINISH KII:; MIRRORED SURFACE. VERIFY LOCATION WITH H&M PROJECT MANAGER. SHOWN ON SHEET E4.1) SCHEDULE TO DETERMINE PROPER TYPE OF LIGHT FIXTURE REQUIRED FOR 0 DOORBELL SYSTEM. REFER TO WIRING DIAGRAM ON DWG.E4.1. THE CEILING CONSTRUCTION PRIOR TO ORDERING THE FIXTURES AND SHALL O4 APPROXIMATE LOCATION OF SECURITY KEY PAD AND KEYSWITCH AT PROVIDE FIXTURES THAT ARE COMPATIBLE WITH THE CEILING SYSTEM. U s220 EMPLOYEE ENTRANCE. VERIFY EXACT LOCATION WITH H&M O ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALLA 100 WATT SERVICE REPRESENTATIVE. SEE E4.1 FOR WIRING DETAILS. 4. ALL DEVICES, EQUIPMENT,FIXTURES,AND THE LIKE,MUST BE GROUNDED BY WASHI NGTC N SQUARE LIGHT WITH SWITCH AND GROUND FAULT DUPLEX RECEPTACLE AT UNIT. DEVICES ARE TO BE WEATHERPROOF WHEN USED OUTDOORS.CONNECTTO USE OF A PROPERLY SIZED GROUNDING CONDUCTOR. ii:: JUNCTION BOX IN CEILING WITH 3/4"CONDUIT AND PULL WIRE TO SECURITY CIRCUIT AS SHOWN. MECHANICAL/ELECTRICAL BONDS OF THE METALLIC RACEWAY SYSTEM 9585 S.W. Washington Square PANEL FOR MOTION SENSOR FURNISHED AND INSTALLED BY OTHERS. SHALL ALSO BE MAINTAINED. O6 REFER TO TYPICAL CASH WRAP ELEVATION ON DWG.E4.2 OR E4.3 AS SUITE H08 NOTED. 5. REFER TO M ECHANICAL PLANS FOR EXACT LOCATION OF MECHANICAL PORTLAND, OR 97223 EQUIPMENT AND LOCATE DISCONNECT SWITCHES IN ACCORDANCE WITH 0 REFER TO ENLARGED PLAN OF THIS AREA ON DWG.E4.1. THE NEC. CLASS: RED KI DUPLEX OUTLET FLUSH MOUNTED IN CEILING AT SHOW WINDOW. RUN 4" 6. REFER TO DIV.15 SPECIFICATIONS, HVAC PLANS AND PLUMBING PLANS FOR SIDE OF COVERPLATE/DEVICE PARALLEL WITH STOREFRONT WINDOW. ADDITIONAL ELECTRICAL WORK AND REQUIREMENTS. 09 MOUNT RECEPTACLE IN FITTING ROOM CORRIDOR AT 12"A.F.F.. 7. ALL RECEPTICLES SHOWN BACK-TO-BACK IN WALLS SHALL BE SEPARATED BY 8" MINIMUM. 10 ACCESS PANEL IN CEILING FOR ACCESS TO ELECTRICAL/MECHANICAL EQUIPMENT. COORDINATE WITH G.C.FOR THE FURNISHING AND 8. WIRING IN PLENUMS SHALL BE PLENUM RATED OR INSTALLED IN CONDUIT. INSTALLAING OF ACCESS PANEL BY G.C. 9. BRANCH CIRCUIT WIRE SIZES (AND CONDUITS) SHALL BE INCREASED FROM K. DATA OUTLET WITH(2)CAT SE CABLE ABOVE ACCESS PANEL IN CEILING FOR THOSE INDICATED ON THE PLANS TO PREVENT EXCESSIVE VOLTAGE DROP. FUTURE TRAFFIC COUNTING DEVICE. BRANCH CIRCUITS SHALL BE INSTALLED WITH WIRES OF SUFFICIENT SIZE SO THAT VOLTAGE DROP BETWEEN THE PANEL AND THE LOADS DOES NOT 12 ELECTRONIC ARTICLE SURVEILLANACE SYSTEM EQUIPMENT. ROUTE(2)3/4" EXCEED A LIMIT OF 3%. 9 RIGID CONDUIT WITH PULLSTRING FROM FLOOR MOUNTED PEDESTAL • EQUIPMENT TO A FULL HEIGHT WALLAND UP INTO"EAS CONTROL 10. WIRE SIZES SHALL BE BASED ON THE 602C.AMPACITIES FOR WIRE SIZES NO CABINET"ABOVE CEILING FOR"EAS"CABLES(BY EAS VENDER),TYPICAL. 14-1 AWG,AND 75 2C.AMPACITIES FOR WIRE SIZES#1/0 AWG AND LARGER. t"t/. '",„;74., ' ELECTRICAL CONTRACTOR IS TO ALSO FURNISH AND INSTALL ASEPARATE 1. i . 3/4"INTER-COMMUNICATION CONDUIT FROM BETWEEN ALL"EAS CONTROL 11. CIRCUITS MAY BE MULTI-PLEXED IN CONDUIT PROVIDED WIRE IS PROPERLY j CABINETS"TO FORM A"COMMUNICATION RING LOOP." ELECTRICAL DEBATED AND CONDUIT SIZED PER CODE. UNDER NO CIRCUMSTANCES `' CONTRACTOR SHALL COORDINATE WITH H&M AND EAS VENDER FOR EXACT LOCATIONS AND REQUIREMENTS FOR EQUIPMENT ROUGH-IN. SHALL MORE THAN NINE(9) CURRENT CARRYING CONDUCTORS BE RUN IN A SINGLE CONDUIT. 13 J-BOX MOUNTED ABOVE THE CEILING FOR POWER TO FUTURE"EAS" EQUIPMENT. COORDINATE CONNECTION WITH EAS E VENDER. 12. ALL CONDUITS SHALL CONTAIN A GROUND WIRE SIZED PER NEC TABLE#250- 122. IN ADDITION,WHERE AN ISOLATED,INSULATED GROUND IS REQUIRED, 14 ONE CAT SE DATA PORT 6"BELOW FINISHED CEILING FOR WIRELESS ACCESS A SEPARATE GREEN GROUND SHALL BE RUN FROM THE PANEL. GROUND NODE. IF INSTALLED NEAR FLOATING CEILING, NODE SHALL BE INSTALLED 6" BUS TO THE ISOLATED GROUND CONNECTION OF THE DEVICE. IN NO CASE BELOW FLOATING CEILING. SHALL THE SYSTEM GROUND(WIRE AND ASSOCIATED OUTLET BOXES, CONDUIT AND BUILDING STEEL)BE ALLOWED TO CONTACT THE ISOLATED 15 PROVIDE JUNCTION BOX,TOGGLE DISCONNECT SWITCH IN NON VISIBLE GROUND(GREEN WIRE AND DEVICE). WHERE CIRCUIT CONDUCTORS ARE LOCATION AND FINAL CONNECTION FOR 120 VOLT SIGN FURNISHED BY H& INCREASED IN SIZE FOR VOLTAGE DROP,THE GROUND WIRE SIZE SHALL BE M.COORDINATE EXACT LOCATIONS WITH H&M CONSTRUCTION MANAGER. INCREASED PROPORTIONALTELY(ACCORDING TO CIRCULAR MIL AREA) H B K ELECTRICAL CONTRACTOR SHALL VERIFY EXACT REQUIREMENTS WITH U.L. FROM THE SIZE REQUIRED BY NEC TABLE#250-122. SECTION 2161 REQUIRING THE USE OF SECONDARY GROUND FAULT PROTECTION AND INCLUDE ALL COST IN BID.POWER JUNCTION BOX IS TO BE CONSULTANTS, LTD MOUNTED IN CENTER OF SIGN BOTH VERTICALLY AND HORIZONTALLY. Mechanical & Electrical Design Services 16 QUADRAPLEX I.G.OUTLETS AND DATAJACKS MOUNTED 36"AFF IN DECO AREA. VERIFY EXACT LOCATION IN ROOM WITH H&M CONSTRUCTION 171 Charring Cross Drive S. MANAGER ON SITE PRIOR TO ROUGH-IN. Suite 1B Westerville, Ohio 43081 614.882.1199 17 JUNCTION BOX FOR MOTORIZED STORE GRILLE, 120 VOLT SINGLE PHASE. FAX 614,882,1857 RUN 2#12THHN AND 1#12 GROUND IN A 3/4"CONDUIT FROM A20 AMP, SINGLE POLE 'AC'TOGGLE SWITCH,FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR TO A 20A-1P BREAKER IN PANEL. PROVIDE ANY NECESSARY WIRING TO GRILLE CONTROL STATIONS AS REQUIRED INCLUDING ANY SPECIAL INTERLOCKS REQUIRED BY LANDLORD.MAKE ALL Drawings and written material appearing herein constitute original FINAL ADJUSTMENTS TO THE LIMITSWITCHES. KEY OPERATED SWITCHES and unpublished work of the Architect and may not be duplicated, SHALL BE PROVIDED BY H&M AND INSTALLED BY THE ELECTRICAL used or disclosed without written consent of the Architect CONTRACTOR AT 18"A.F.F.AND SHALL BE FULLY RECESSED IN WALL AT C®AI B H ARCHITECT - 2 0 1 0 STOREFRONT OR IN COLUMN.REFER TO ARCHITECTURAL PLANS FOR LOCATION AND MOUNTING DETAILS OF KEY SWITCH. RECESS BOXES FOR KEY SWITCH,EMERGENCY RELEASE AND INTERLOCK SWITCH INTO COLUMN DEEP Q A Q C ENOUGH TO ASSURE CUSTOM COVERPLATES WILL FIT FLUSH AGAINSTTHE N o. D o t e I s s u e COLUMN. 05/28/10 100% SET 18 1/2"CONDUIT WITH PULL WIRE FROM BACKBOX(WITH PLASTER RING)UP IN 05/2$/10 VT PACKAGE WALL TO eSTAT PANEL IN ELECTRIC ROOM FOR THERMOSTAT/SENSOR WIRING BY OTHERS.COORDINATE MOUNTING HEIGHT WITH MECHANICAL 07/02/10 100% COMPLETE SET CONTRACTOR AND H&M CONSTRUCTION MANAGER IN FIELD PRIOR TO 07/2$/10 LANDLORD SET ROUGH-IN. 08/13/10 PERMIT/BID SET 19 RECESSED DUPLEX FLOOR OUTLET LOCATED 4"OUT FROM SHOW WINDOW DISPLAY WALL TO CENTER. COORDINATE EXACT LOCATION IN FIELD WITH ARCHITECT AND H&M CONSTRUCTION MANAGER. 20 NT DAMPER TRANSFORMER FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. 120 VOLT POWER WIRING BY ELECTRICAL CONTRACTOR AS SHOWN. 21 1/2"CONDUIT WITH PULL WIRE FROM BACKBOX(WITH PLASTER RING)UP IN WALL TO RESPECTIVE"VVT"UNIT FOR THERMOSTAT/SENSOR WIRING BY OTHERS.COORDINATE MOUNTING HEIGHT WITH MECHANICAL CONTRACTOR AND H&M CONSTRUCTION MANAGER IN FIELD PRIOR TO ROUGH-IN. • • 22 ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT FROM ELEVATOR MACHINE UNIT ITSELF TO THE LAN ROOM. TECHNOLOGY CONTRACTOR SHALL SUPPLY(1)CAT SE CABLE LEFT UNTERMINATED IN MACHINE UNIT AND PUNCH DOWN THE BLUE/BLUE WHITE PAIR TO THE 66 BLOCK BLADES CORRESPONDING TO THE"POTS"LINE SUPPLIED FOR THE ELEVATOR IN THE LAN ROOM. Project No. 44122/10038 NM Scots AS NOTED ALL WIRING MUST BE IN CONDUIT 1!!!!!!!! o.n e,: REK EMT or RIGID FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK AND AS THE FINAL JA2010 John\10038\US220E34.d«9 I' CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE o SIZE TO RECESSED FIXTURES, MOTORS AND Droning No. R ELECTRICAL EQUIPMENT THAT MAY GENERATE VIBRATION THROUGH THE CONDUIT SYSTEM. GENERAL NOTES AND CODED NOTES I r< GENERAL NOTES AND CODED NOTES NONE 1 I - E3 .4 • CIRCUIT "A-19" CEILING Igill 3—PORT DATA OUTLET TRANSFORMER — EDWARDS 120V, 10 "88-250" MOUNTED ON WALL I N (TYP) , LOUNGE ABOVE CEILING. QUADRAPLEX IG 2—PORT DATA OUTLET. ■ RECEPTACLE ON A 8V, 10 DEDICATED CIRCUIT (TYP) . - .. — 0 6" 6" 1-;" PUSHBUTTON — EXPRESSIONS—LTD BUZZER — EDWARDS "661" MOUNTED IN US220 "SS—STANDARD—RECT" QUANITITY AS B • WALL AT 8'-0" A.F.F. IN SHOWN ON PLANS. WIRE MULTIPLE BACK—OF—HOUSE AND ON COLUMN WASHINGTON SQUARE = PUSHBUTTONS IN PARALLEL. ENCLOSURE AT 8'-0" A.F.F. . B QUANTITY AS SHOWN ON PLANS COUNTER (TYPICAL). 9585 S.W. Washington Square are SUITE H08 PORTLAND, OR 97223 CLASS: RED NOTE: ALL LOW VOLTAGE WIRING TO BE #14 THW. FLOOR 3 DOORBELL WIRING DIAGRAM E4.1 N.T.S. ELEVATION "A" GENERAL NOTES 1 . ALL DATA OUTLETS ARE ARBITRARLY LABELED AS DATA AS DATA AND a •TELEPHONE DEVICES USE THE SAME JACK. THE H&M I T REPRESENTATIVE OTO LANDLORD'S 4-::.. '',' 1 SHALL DETERMINE WHICH JACKS WILL BE USED FOR DATA AND FOR TELEPHONE TERMINATION '(''` (4' TELEPHONE . ROOM. VERIFY EXACT r. �;. LOCATION IN FIELD WITH LANDLORD PRIOR TO BID PANEL "HP" AND INCLUDE ALL COSTS 277/480. , 30 , 4W. fF , N BID. --------.�„ �:...�.�� AD I NISTRATION ROOM ELEVATION WIREWAY AND 30A-3P FUSED ° ..Ci)4N.T.S. ` DISCONNECT SWITCHES FOR 411( ESCALATORS. SEE POWER RISER FOR ADDITIONAL INFORMATION. PANEL "LP3" 277/480V. , 30, 4W. r ._1 A� A-23 I © =AR ......... : .. GA-2 2GA-1 2 7 D O I-I B K II I ROOM O • L 1 GA-18 L 1 GA-4 L 1 GA-2 2 CONSULTANTS, LTD 1G �Lr" :1.I r� - 45 KVA TRANSFORMER "T1 " . 30 KVA "T2" Mechanical & Electrical Design Services 11 ID ADMIN / s J, "` , �� AND 15 KVA "T3" TRANSFOMER STACKED IG ROOM C .►1 A!IP4 —� ON A FLOOR MOUNTED UNISTRUT FRAME ELEV. A " O �•••• 18 171 Charring ross Drive S. I ' 0 60 © �.■�i♦ .� ELEC WITH LARGEST TRANSFORMER MOUNTED ON Suite 18 g {D) Ti�� FLOOR; 480V. , 345, 3W. PRIMARY, Westerville, Ohio 43081 /jam �tDOM T2 120/208V. , 30, 4W. SEC. 814.882.1199 E 4.1 1:1 Fr T 3 FAX 814,882,1857 I L1GA-20 L1GA-3 Q j L --- 1 (D) L1GA-14 IF PANEL "A" L1GA-8 ' —4011 A-2 A-2 .- 120/208V. , 30, 4W. Drawings and written material appearing herein constitute original SIG o Hi U and unpublished work of the Architect and roof not be duplicated, — (5 WALL MOUNTED SOUND I „ L1 GA-16 ,.�____ «, RACK, SEE SHEET E3.30 __..i PANEL "B" used or disclosed without written consent of the Architect AND E3,3b FOR 120/208V. , 30, 4W. @MBH ARCHITECT - 2010-4I 111 ADDITIONAL INFORMATION, IIG 41) ir. , PANEL "LlGA" OAOC i A-21 ii .(D; © 36 AFF 120/208V. , 30, 4W. I No. Dole Issue —� PANEL "LP2" PANEL 120/208V. ," 3rd, 4W. 05/28/10 100% SET L 1 GA-21 A6" 05/28/10 VT PACKAGE MTG/SEC =0"8r. : "30, 07/02/10 100% COMPLETE SET Ic ROOM, � 4W. 07/28/10 LANDLORD SET Ki: 36" AFF , (D; 08/13/10 PERMIT/BID SET CODED NOTES 0 1 1/2" CONDUIT WITH PULL STRING BY ELECTRICAL CONTRACTOR FOR TELEPHONE SERVICE FROM LANDLORD'S TELEPHONE CLOSET TO LAN ROOM IN H&M SPACE. VERIFY IN FIELD EXACT LOCATION OF MAIN TELEPHONE BOARD AS WELL AS WELL AS ANY INTERMEDIATE BOARD LOCATIONS. N TECHNOLOGY CONRACTOR IS TO PROVIDE CATS RATED 25—PAIR CABLE FROM LANDLORD TELEPHONE CLOSET. REFER TO SPECIFICATIONS FOR ADDITIONAL I III INFORMATION. COORDINATE REQUIRED DISTANCE WITH LANDLORD PRIOR 2 ENLARGED ADMINISTRATION AND MEETING/SECURITY ROOMS LOCATBONTOFNSMAR°' JACKECFORCH&M CONTRACTOR TELEPHONE SERVICE COORDINATE WITHIN E4.1 1/4"=1'-O" 300 FEET OF H&M SPACE . ® JUNCTION BOX AND QUADRAPLEX RECEPTACLE FOR SECURITY PANEL . K 4 '-0" HIGH x 8'-0" WIDE x 3/4" THICK FIRE TREATED PLYWOOD TELEPHONE/DATA BOARD WITH QUADRAPLEX RECEPTACLE . MOUNT ADMINISTRATION ROOM CODED NOTES BOARD AT 2'-0" AFF TO BOTTOM. K TWO POST NETWORK LADDER DATA RACK WITH 3" UPRIGHTS. REFER TO 2—PORT OR 3—PORT DATA OUTLET IN WALL . SEE ELEVATION FOR ADDITIONAL SPECIFICATIONS FOR ADDITIONAL INFORMATION. RACK BASE SHALL INFORMATION. BE LOCATED 6" FROM PLYWOOD WALL AND 22" FROM ADJACENT WALL . QUADRAPLEX RECEPTACLE SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR (2) JUNCTION BOX ABOVE CEILING FOR DOOR LOCK POWER. IN LINE WITH RACK BASE . Project No. 44122/10038 • (3) JUNCTION BOX ABOVE CEILING FOR DOOR INTERLOCK WIRING TO SAFE . (5) IG RECEPTACLE FOR SOUND SYSTEM AMPLIFIER. ELECTRICAL CONTRACTOR IS TO ENGRAVE COVERPLATE IN RED TO SAY "AMPLIFIER" . Scole AS NOTED 0 JUNCTION BOX BEHIND SAFE FOR INTERLOCK BETWEEN SAFE AND DOOR LOCK. 0 LIGHT CONTROL PANELS AND eSTAT PANELS FURNISHED BY OTHERS. ELECTRICAL O 3/4" CONDUIT ABOVE CEILING FOR DOOR/SAFE INTERLOCK FURNISHED AND CONTRACTOR IS TO INSTALL LIGHTING CONTROL PANELS AND WIRE LIGHTING Drowsily: REK INSTALLED BY ELECTRICAL CONTRACTOR. CIRCUITS THRU RELAYS AS CALLED FOR ON SHEET E4 .4. . ELECTRICAL ALL WIRING MUST BE IN CONDUIT CONTRACTOR I S TO FURNISH AND INSTALL DUPLEX RECEPTACLES NEXT TO "LCP'S" EMT or RIGID AND "eSTAT" PANELS FOR LOCAL PLUG—IN POWER SUPPLIES. a N .I:\2010 aabs\>10a> us2 41.de9 E E T NG/SECURITY ROOM CODED NOTES METAL ASE THE FINAL CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, ENLARGED ELECTRIC AND LAN ROOMS Droving No. 14 2—PORT OR 3—PORT DATA OUTLET I N WALL. MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE E4.1 1/4".1'-0" ELECTRICAL SIZE TO RECESSED FIXTURES, MOTORS AND KII2 IG QUADRAPLEX RECEPTACLE AND 3—PORT DATA OUTLET FOR SECURITY ELECTRICAL EQUIPMENT THAT MAY GENERATE DETAILS - 1 EQUIPMENT. VIBRATION THROUGH THE CONDUIT SYSTEM. I r= AS NOTED 1 1 ELECTRICAL DETAILS _ . 2 E4 B 7tim , _____ r - -1 r 1 r -1 r -1 I I QUADRAPLEX CONVENIENCE I I I I I I I RECEPTACLE, QUADRAPLEX I I I I I I 1 ISOLATED GROUND I I I I I I RECEPTACLE, TELEPHONE L OUTLET AND DATA OUTLET L J L L J US22 0 LOCATED UNDER THE SQUARE ACCESS PANEL I N BOTTOM WASHINGTON OF MILLWORK (TYPICAL) . — 9585 S.W. Washington Square ACCESS PANEL I N 111111111k SUITE HO8 BOTTOM OF MILLWORK PORTLAND, OR 97223 ____ I I i. I I I CLASS: RED I oo©�© ! O 4 23/32" t �e 2 o ©Q '© _ - - o o©�©_ I IG DATA IG DATA IG DUPLEX RECEPTACLE WITH ' HAND HOLE FOR ROLL—UP ISOLATED GROUND MOUNTED HOLIDAY CASHWRAP. - ON SIDE OF MILLWORK UNDER ACCESS PANEL FOR FIRE RATED POKE-THROUGH FOR FUTURE HOLIDAY CASHWRAP WIRING. PROVIDE A HUBBELL #PT7XC FIRE (TYPICAL BOTH ENDS) RATED POKE-THROUGH UNIT WITH A 2-GANG PEDESTAL SERVICE FITTING #FR8OAL AND BRUSHED DATA OPENING #SS309T. USE 1 1/4" FIRE RATED POKE-THROUGH FOR CASHWRAP �. OD SECTION A CONDUIT FOR FUTURE WIRING. BRANCH CIRCUITS WITH ISOLATED GROUND. f� `. PROVIDE A HUBBELL #PT7XC FIRE RATED NTS POKE-THROUGH UNIT WITH A 2-GANG PEDESTAL _ SERVICE FITTING #FR8OAL AND FURNITURE FIRE RATED POKE-THROUGH FOR CASHWRAP FEED OPENING #SS309SF. USE 1 1/4" ,� � UTILITY BRANCH CIRCUITS. PROVIDE A CONDUIT FOR ISOLATED GROUND POWER FEED. t HUBBELL #PT7XC FIRE RATED POKE--THROUGH EXTEND LIQUID TIGHT FLEXIBLE METALLIC •.UNIT WITH A 2-GANG PEDESTAL SERVICE CONDUIT TO ISOLATED GROUND DEVICE PER �« r .,�,._ + FITTING #FR8OAL AND FURNITURE FEED PLANS. OPENING #SS309SF. USE 1/2" CONDUIT FOR FIRE RATED POKE-THROUGH FOR CASHWRAP :: POWER FEED. EXTEND LIQUID TIGHT FLEXIBLE DATA/TELEPHONE CABLING. PROVIDE A METALLIC CONDUIT TO ISOLATED GROUND HUBBELL #PT7XC FIRE RATED POKE-THROUGH DEVICE PER PLANS. UNIT WITH A 2-GANG PEDESTAL SERVICE FITTING #FR8OAL AND BRUSHED DATA OPENING #SS309T. USE 1 1/4" CONDUIT FOR DATA/TELEPHONE WIRING. EA SECTION A - 3 REGISTER CASHWRAP E4.3 NTS H B K CONSULTANTS, LTD Mechanical & Electrical Design Services 171 Charring Cross Drive S. 1 1/4" TELEPHONE/DATA Suite 18 BACK TO "LAN ROOM" . B--25, 27 AND 29 Westerville, Ohio 43081 614.882.1199 FAX 614,882,1857 L1GA-15, 17, 23 FUTURE TO ELECTRIC AND 25 ROOM. STUB INTO ROOM 7, AND LABEL CONDUIT END. Drawings and written material appearing herein constitute original and unpublished work of the Architect and may not be duplicated, used or disclosed without written consent of the Architect Ok18H ARCHITECT - 2010 OAOC . No. Dote Issue . 05/28/10 100% SET . I //////// 05/28/10 VT PACKAGE • 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET 08/13/10 PERMIT/BID SET .•i _ is - A L1GA-25 0 0 0 L1GA-25 IG .6 4s - N IG Au. D 4 1. ,.'. ELECTRICAL CONTRACTOR I S TO ■ ■ 1111,r1 1 ■O ■O■- FURNISH AND INSTALL HOLIDAY Is. Z~ ''' NI RECEPTACLE I N CASHWRAP AS 03 r r— co r— coo DIRECTED BY H & M CONSTRUCTION I N l —' I I FIELD (TYP. OF 2) . > > v b I I N -' W -1 0i ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL RECEPTACLES AND TELEPHONE/DATA OUTLETS IN CASHWRAP AS DIRECTED BY H & M CONSTRUCTION IN FIELD (TYP) . GENERAL NOTES ALL WIRING MUST BE IN CONDUIT Project No. 44122/10038 1 . REFER TO DRAWING SERIES "E3.x" FOR QUANTITY AND LOCATIONS OF ALL ELECTRICAL CONTRACTOR IS TO EMT or RIGID POWER AND DATA DEVICES. FURNISH AND INSTALL UNDERFLOOR CONDUITS FROM WALL AND STUB UP FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR 2. ALL JACKS ARE ARB I TRAP I LY LABELED AS DATA. TELEPHONE USES THE 4" DUI AFF. COORDINATE EXACT S c o I e AS NOTED CONNECTIONS INSIDE CASEWORK AND AS THE FINAL SAME JACKS. THE H&M I .T. REPRESENTATIVE SHALL DETERMINE WHICH JACKS ARE DATA AND WHICH ARE TELEPHONE (TYPICAL). LOCATIONS WITH H & M CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, CONSTRUCTION MANAGER IN FIELD MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE 3. ALL FLOOR CONDUIT PENETRATIONS SHALL BE FIRE RATED OR FIRE PRIOR TO INSTALLATION. D r o w s i l y: REK SIZE TO RECESSED FIXTURES, MOTORS AND STOPPED AS REQUIRED BY THE LOCAL JURISDICTION AND/OR LANDLORD. ELECTRICAL EQUIPMENT THAT MAY GENERATE VIBRATION THROUGH THE CONDUIT SYSTEM. 4. PROVIDE HUBBELL "SS309B" BLANK FACEPLATES FOR UNUSED PEDESTAL COMPARTMENTS. ENLARGED 3-REGISTER CASHWRAP PLAN \2810.lobs\10038\US220E42.d.9 i E4.3 1/2"_1'-0" IIIIIIIII o Droving No. g ELECTRICAL DETAILS I g AS NOTED 1 1 ELECTRICAL DETAILS _ E4. 2 B Iii&iti E - 1 r 1 F 1 r 1 F I I QUADRAPLEX CONVENIENCE I I I I 1 1 I 1 I 1 RECEPTACLE, QUADRAPLEX 1 I 1 I I I I I I ISOLATED GROUND 1 I 1 1 1 1 I RECEPTACLE, TELEPHONE US220 1— OUTLET AND DATA OUTLET L J L J _ L J L J LOCATED UNDER THE WASHINGTON SQUARE ACCESS PANEL IN BOTTOM I OF MILLWORK (TYPICAL) . '~ — 9585 S.W. Washington Square SUITE H08 I ACCESS PANEL IN - PORTLAND, OR 97223 BOTTOM OF MILLWORK J CLASS: RED 1 ----------- ----A- t---- ----- 0 i I ©p�©©o o ©0©© ©©�©© - - - - 1 0 1-4 23/32 I ©pp©o o ©tom© ©fit 0 v©gyp IG DATA IG IG DATA IG DUPLEX RECEPTACLE WITH ' HAND HOLE FOR ROLL-UP ISOLATED GROUND MOUNTED HOLIDAY CASHWRAP. ON SIDE OF MILLWORK •• • UNDER ACCESS PANEL FOR FIRE RATED POKE—THROUGH FOR FUTURE HOLIDAY CASHWRAP WIRING. PROVIDE A HUBBELL #PT7XC FIRE RATED POKE—THROUGH UNIT WITH A 2—GANG (TYPICAL BOTH ENDS) PEDESTAL SERVICE FITTING #FR8OAL AND `_.. . BRUSHED DATA OPENING #SS309T. USE 1 1/4" FIRE RATED POKE—THROUGH FOR CASHWRAP ~' B SECTION A CONDUIT FOR FUTURE WIRING. BRANCH CIRCUITS WITH ISOLATED GROUND. , PROVIDE A HUBBELL #PT7XC FIRE RATED E 42. NTS POKE—THROUGH UNIT WITH A 2—GANG PEDESTAL 'Y .` SERVICE FITTING #FR8OAL AND FURNITURE i''r FEED OPENING #SS309SF. USE 1 1/4" a C ,$ FIRE RATED POKE—THROUGH FOR CASHWRAP CONDUIT FOR ISOLATED GROUND POWER FEED. UTILITY BRANCH CIRCUITS. PROVIDE A EXTEND LIQUID TIGHT FLEXIBLE METALLIC \ ,, ,$ HUBBELL #PT7XC FIRE RATED POKE—THROUGH CONDUIT TO ISOLATED GROUND DEVICE PER UNIT WITH A 2—GANG PEDESTAL SERVICE • FITTING #FR8OAL AND FURNITURE FEED PLANS. OPENING #SS309SF. USE 1/2" CONDUIT FOR FIRE RATED POKE—THROUGH FOR CASHWRAP FEED. EXTEND LIQUID TIGHT FLEXIBLE DATA/TELEPHONE CABLING. PROVIDE A METALLIC CONDUIT TO ISOLATED GROUND HUBBELL #PT7XC FIRE RATED POKE—THROUGH DEVICE PER PLANS. UNIT WITH A 2—GANG PEDESTAL SERVICE FITTING #FR8OAL AND BRUSHED DATA OPENING #SS309T. USE 1 1/4" CONDUIT FOR DATA/TELEPHONE WIRING. A SECTION A - 4 REGISTER CASHWRAP E4.2 NTS H B K CONSULTANTS, LTD Mechanical & Electrical Design Services 171 Charring Cross Drive S. Suite 18 1 1/4" TELEPHONE/DATA A-3, 5, 7 AND 9 614 882111,99 Ohio 43081 BACK TO "LAN ROOM" . FAX 614,882,1857 L1GA-5, 7, 9, 11 FUTURE TO ELECTRIC AND 13 ROOM. STUB INTO ROOM AND LABEL CONDUIT Drawings and written maleriol appearing herein constitute original END. and unpublished work of the Architect and soy not be duplicated, used or disclosed without written consent of the Architect cJMBH ARCHITECT - 2010 •p♦ +rte• OAOC No. Dote Issue ✓• r r 05/28/10 100% SET . . 05/28/10 VT PACKAGE ,----//////////\.— i / 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET 08/13/10 PERMIT/BID SET r ■ r ■ ■ A L 1 GA-13 O U 0 Q ZE L 1 GA-13 ©IG IG � � d ,��� 0 ELECTRICAL CONTRACTOR I S TO A _ ■ ■ gym■ " +�.. FURNISH AND INSTALL HOLIDAY ' .�. '�� ® � � RECEPTACLE I N CASHWRAP AS V> r r y > r— r— > DIRECTED BY H & M CONSTRUCTION IN i i I \ I FIELD (TYP. OF 2) . c0 D D v t1 D D W 1 i t0 '.I 01 • • ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL RECEPTACLES AND TELEPHONE/DATA OUTLETS IN CASHWRAP AS DIRECTED BY H & M CONSTRUCTION IN FIELD (TYP) . NM Project No 44122/10038 IS TO GENERAL NOTES FURNISH ELECTRICAL ALL WIRING MUST BE IN CONDUIT CONDUITS FROM WALL AND STUB UP S c a l e AS NOTED EMT or RIGID 1 . REFER TO DRAWING SERIES "E3.x" FOR QUANTITY AND LOCATIONS OF ALL 4 AFF . COORDINATE EXACT NM POWER AND DATA DEVICES. ()royally:LOCATIONS WITH H M CONSTRUCTION MANAGER IN FIELD REK FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR 2. ALL JACKS ARE ARBITRAPILY LABELED AS DATA. TELEPHONE USES THE PRIOR TO INSTALLATION. CONNECTIONS INSIDE CASEWORK AND AS THE FINAL SAME JACKS. THE H&M I .T. REPRESENTATIVE SHALL DETERMINE WHICH CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, JACKS ARE DATA AND WHICH ARE TELEPHONE (TYPICAL). MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE 3 3. ALL FLOOR CONDUIT PENETRATIONS SHALL BE FIRE RATED OR FIRE J:�70rb dobe�t003a�uS220E43.d�q IF SIZE TO RECESSED FIXTURES, MOTORS AND STOPPED AS REQUIRED BY THE LOCAL JURISDICTION AND/OR LANDLORD. ELECTRICAL EQUIPMENT THAT MAY GENERATE " " 2 ENLARGED LARGE 4-REGISTER CASHWRAP PLAN IIIIIIII Ti VIBRATION THROUGH THE CONDUIT SYSTEM. 4. PROVIDE HUBBELL SS309B BLANK FACEPLATES FOR UNUSED PEDESTAL 0 r o r i e No. ° COMPARTMENTS. E4.2 1/2":l'-0" R ELECTRICAL DETAILS 1 AS NOTED 1 ELECTRICAL DETAILS _ k E4.3 I „illralm • ('''s. i LINE VOLTAGE CONNECTIONS FROM CIRCUIT BREAKER PANEL TO TOP TERMINALS OF CONTACTORS. f CONTROL CIRCUIT FIELD WIRING US220 L IN E VOLTAGE V TA CONNECTIONS FROM CIRCUIT WASHINGTON SQUARE BREAKER PANEL TO TOP TERMINALS OF CONTACTORS. CONTROL CIRCUIT 9585 S.W. Washington Square T 3 PANEL 1 TE MINIM. FLOCK SUITE H08 PORTLAND, OR 97223 N CLASS: RED E G H U R TDPNEL2 ❑ -J- ❑ LP3-7 LP3-9 LP3-15 LP3-17 SPARE SPARE TE RMI AL BLOCK T U LP3-4 LP3-11 LP3-13 SPARE LP2-10 SPARE R N - - - . _ _ ■ . - - - - N G A D ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ H E R L �. ❑ T ❑ _ T 11 .11 liii iii L D WORK WORK WORK LP1-3 LP1-4 LP1-7 LP1-8 LP1-11 LP1-12 LP1-15 LP1-16 LP1-1 LP1-5 LP1-6 LP1-9 LP1-10 LP1-13 LP1-14 LP1-17 `4. ■ ■ s 22 22 ■■ ■■ ■■ w ■■ w W . ■ ■ ■ ■ ■ ■ ■ ■ ■ LP3-3 LP3-5 SPARE SPARE LP2-2 LP2-3 SPARE SPARE era [ii erg Li wra ill era I ill i ri CI LP3-1 LP3-18 LP2-6 SPARE LP2-1 LP2-4 LP2-5 SPARE mmilymma Wi ,��Pli ININIIMINII twr• t• wr• ii ii rrr■iih 2222 2222 2 22 FIi ' Q��] p ' p���p ,, ,, Irk ,, ,, i, ,1 ,, s, ,, II ,* , r, ♦, ,i ■ ■ ■ ■ ■ ■erg erg erg �r� erg erg erar� C13(era !1!I era 11a �a i r: rig 1 i 1 1 1*1 I 1 I 1.1 1 1 1 a. - - - — , TRACK TRACK TRACK TRACK IE 'l' I 'I 1 ■ IM 1 ifitil SALES SALES SIGN/DISPLAY SIGN/DISPLAY CONSULTANTS, LTD Mechanical & Electrical Design Services 171 Charring Cross Drive S. Suite 1B Westerville, Ohio 43081 `e • LP1-19 LP1-20 LP1-23 LP1-24 LP1-30 LP1-32 LP1-39 LP1-41 SPARE SPARE F1 9 FAX X 614 614,,88$82,1857 LP1-18 -- LP1-21 LP1-22 LP1-26 LP1-28 LP1-34 LP1-36 LP1-42 SPARE SPARE Oirrill ■ ■ ■ ■ 11141:11 NINO t I lI lJ■ ■ ■ ■ , M 22c22 2 222 r , jcJIacI iiiiMIIIPA IMM AIa � jIIaIa :� � and unpublished work of the Architect and may not be duplicated,ril used or disclosed without written consent of the Architect • / ©NBH ARCHITECT - 2010■ iiI 1,1 ■I iii 1 ■ 11 ■1' TRACK TRACK TRACK TRACK TRACK O A O C No. Dole Issue 05/28/10 100% SET 05/28/10 VT PACKAGE A:\ 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET LOAD CONNECTIONS TO LIGHTS ON BOTTOM TERMINALS LOAD CONNECTIONS TO LIGHTS ON BOTTOM TERMINALS SPARE CONTACTOR POLES WILL ALLOW FOR FUTURE LOADS. SPARE CONTACTOR POLES WILL ALLOW FOR FUTURE LOADS, 08/13/10 PERMIT/BID SET LLO LIGHTING CONTACTOR SCHEDULE PANES #1 LIGHTING CONTACTOR SCHEDULE PANEL #2 Firm Name and Address LIGHTSTAT INC . 22 W. WEST HILL ROAD BARKHAMSTED, CT . 06063 Project No. 44122/10038 mil. 800 - 292 - 2444 Scole AS NOTED ALL WIRING MUST BE IN CONDUIT REK D r a v n B EMT or RIGID Project Name and Address r FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR CONNECTIONS INSIDE CASEWORK AND AS THE FINAL H $e M #220 a CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, WASHINGTON SQUARE J\2OIO Jolbs\10038\US220E44'd.p I. MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE PORTLAND, OREGON iii SIZE TO RECESSED FIXTURES, MOTORS AND 9 ELECTRICAL EQUIPMENT THAT MAY GENERATE Droving No. IZ VIBRATION THROUGH THE CONDUIT SYSTEM. V LIGHTING CONTROL 4 DETAILS AS NOTED LIGHTING CONTROL DETAILS _ i E4.4 TO WORK LIGHTS MOTION SENSOR(S) (BLUE CABLE) FACTORY SUPPLIED LOW VOLTAGE COLOR CDED PLENUM RATED CABLES e 009D 0m 9D OS oiD INPUT CABLES FROM THERMOSTATS LOADS TO LIGHTING FIXTURES - -1 BLES 0 AAA 6 Sensors AAA AAA 1 2 3 wired In 1 2 3 1 2 3 ara1Ee1 'I THERMOSTAT 43 ON E-STAT CABINET p THERMOSTAT 111 ON E-STAT CABINET THERMOSTAT 02 ON E-STAT CABINET WIRED TO A1,A2 AND STAT 113 TERMINALS WIRED TO A1,A2 AND STAT 41 TERMINALS WIRED TO AI,A2 AND STAT N2 TERMINALS ,�r�'� rt'4019I13 US220 O ! v, yr ,: O "......„,.. — O -divr O TD RTU & TD RTU & �N ��.. �.=ma= m®m WASHINGTON SQUARE SENSORS ± SENSOR O O 0 p C=== O I I e L - 9585 S.W. Washington Square FROM LIGHTING CIRCUIT — „„ — —' — BREAKERS TO AUTOMATIC o 'iv iTL-1.J' _ g' '°"°' t 8,.,,�.. _I) BLACK 0 _2,..,....-,...SENSEI_IR - _LIGHTING CONTROL CONTACTORS CABLE �'�`-_ - PORTLAND, OR 97223 ei► YELLOW (- CLASS: RED BLUE CABLE • CABLE 4 o .--0 –o-- 'Q o .- Q o• _ _ _ --.-) 0 0 0 0 I- AUTOMATIC I AUTOMATIC 7 .°-- LIGHTING LIGHTING I STORE ELECTRICAL I 1 1 CONTROL CONTROL LIGHTING PANEL(S) o °� o ° o 0 PANEL 2 1 PANEL 1 I 1 0 0 0 F-- ..---- ---] ■...> I omen V1 I I .---------)\ A 1 1 1 1 I 1 1 THIS AREA FOR CLASS 2 CJNTRDL CIRCUIT iga,M 1 1 DENETRATION & TERM NATION ONLY // r 1 I 1 w.. 1 o • • • • I 1 _Xji • • 1' . I _l L1 - - I : : ,x,b� eCo� SSSSSSSGSGG000GSG in il 10 I 1 • • • � Iiaa',-c..-r���;., .._ rrw' "a.-r .,4,�.0 1, X FIELD WIRING x • • CPI • • t am r �� ..try—� -I-) I 1 • • NT -FA �, , �G A I- DEDICATED 1 ( �J • •� .ire 7., _.o_ :NI_ _.■_ _,■_ _.■. r gt/Y-Zati,.7: ,, 120VAC CIRCUIT TO POWER ALC • • 1 • L____ _ ____ I . • BLANK WORK SALES SIGN BLANK BLANK TRACK I • ,,, - E • -.I g 0 • , ,,, ,,,,, , , , , , Ti RELAY GI RELAY G2 RELAY G3 RELAY G4 RELAY G5 RELAY G6 1 A� L GRWP1 62 G3 G3 q �c GRWP4 q G5 G. p • 120 120 + + I- + 1 + 12 1 12 + I- + 12 11 •• • k Ali Ali At Ak /t ink it At At Max Torque \! \R \I \P \ \! \P \ \ 111/ \ /!► � \ ► ■ 71n-1b \i ■ —VP ril TO 20 AMP CIRCUIT BREAKER AUTOMATIC LIGHTING CONTROL RISER DIAGRAM PROVIDED BY OTHERS M Motion sensor — REFER TO LIGHTING PLANS FOR LOCATIONS. li B K CONSULTANTS, LTD Mechanical & Electrical Design Services 171 Charring Cross Drive S. Suite 1B AUTOMATIC LIGHTING CONTROL LOW VOLTAGE CONNECTIONS Westerville, Ohio 43081 614.882.1199 FAX 614,882,1857 #18 AWG-2C, UN—SHIELDED WIRE - #18 AWG-2C, UN—SHIELDED WIRE #18 AWG — 2 CONDUCTOR YELLOW WIRE TO LIGHTING CONTROL CABINET STAT#1 TERMINALS FROM SUPPLY AIR SENSOR TO FROM SUPPLY AIR SENSOR TO E—STAT E—STAT (BY CONTRACTOR) (BY CONTRACTOR) TYPICAL ROOFTOP UNIT Drawings and wriltea material appearing herein constitute original #18 AWG-2C, UN—SHIELDED WIRE - #18 AWG-2C, UN—SHIELDED WIRE #18 AWG — 2 CONDUCTOR BLACK WIRE TO LIGHTING CONTROL CABINET STAT#2 TERMINALS �� � o n d u n p u b l i s h e d a o r k of the Architect and may not be duplicated, FROM REMOTE SENSOR TO E—STAT FROM REMOTE SENSOR TO E—STAT mom used or disclosed without written consent of the Architect (BY CONTRACTOR) (BY CONTRACTOR) amilm =no CC VBH ARCHITECT- 2010 #18 AWG-8C, UN—SHIELDED WIRE - #18 AWG-8C, UN—SHIELDED WIRE #18 AWG — 2 CONDUCTOR BROWN WIRE TO LIGHTING CONTROL CABINET STAT#3 TERMINALS mum mum mum 1 FROM RTU TO E—STAT FROM RTU TO E—STAT anomm mom mum anum (BY CONTRACTOR) (BY CONTRACTOR) Q A Q C Nom anno I .�' No. Dote Issue..... ...... r-i-:--: .�" 05/28/10 100% SET TO CUSTOMER NETWORK C#1 0 #2 NOTE: MODEL SHOWN IS TO CUSTOMER NETWORK - '7 #l ; [#2jJ NOTE: MODEL SHOWN IS 05/28/10 VT PACKAGE CONNECTION 1 I EPC—S—GC--3 CONNECTION 1 �. EPC—S—GC-4 (BY I.T. CONTRACTOR) ° CABINET DIMENSIONS ARE o ° ; ° CABINET DIMENSIONS ARE SUPPLY AIR DUCT 07/02/10 100% COMPLETE SET #3 (BY I,T. CONTRACTOR) a » „ » L=16" W=16" D=3.5" #3, #4. L=16 W=16" D=3.5" ( o rt 1 FLUSH OR SURFACE MOUNT 1 — —' 1 FLUSH OR SURFACE MOUNT SUPPLY AIR SENSOR 07/28/10 LANDLORD SET MOUNT ON DISCHARGE AIR DUCT WITH — ____] • L_ I 0° co 4.; PROBE IN DISCHARGE AIR STREAM 08/13/10 PERMIT/BID SET La W r c co N 2 WIRE #18 AWG Aisammor 6 t TYPICAL E—STAT PRE MOUNTED CABINETS ED ° 0 0 PRE—MOUNTED REMOTE ROOM SENSOR Firm Name and Address e—Stat (TYPICAL) MOUNT IN SPACE TO MECHANICAL SPECIFICATIONS: ELECTRICAL SPECIFICATIONS: BE CONTROLLED CONTROLS LIGHTSTAT AUTOMATIC LIGHTING CONTROL L_ I G H T S T A T I N C PROVIDE ALL TEMPERATURE CONTROLS MODIFICATIONS REQUIRED FACTORY SUPPLIED AS A COMPLETE SYSTEM AND INCLUDES THE 22 W. WEST HILL READ FOR A COMPLETE AND FUNCTIONING CONTROLS SYSTEM, FOLLOWING COMPONENTS: B A R K H A N S T E D, CT . 0 6 0 6 3 Project e M 0. 44122 10038 THERMOSTATS SHALL BE LIGHTSTAT MODEL E—STAT—AG PRE—MOUNTED TO CABINET. PRE—MOUNTED E—STAT CABINETS LIGHTING CONTROL CONTACTOR PANEL TYPICAL E—STAT WIRING SCHEMATIC 800 - 292 - 2444 AND SENSORS AS MANUFACTURED BY LIGHTSTAT INC. 4 POLE 20 AMP CONTACTORS, MAGNETICALLY HELD, 120 VOLT AC COILS CONTRACTOR SHOULD CONTACT LIGHTSTAT TO ARRANGE PAYMENT S c a l e AS NOTED AND PROCESS ORDER, ALLOW TWO WEEKS FOR DELIVERY, MOTION SENSOR(S) IIIIIIIII FOR ADDITIONAL INFORMATION CONTACT: 6 REMOTE SENSORS PRE CALIBRATED FOR MINIMUM ON OPERATION. UNITS LIGHTSTAT, INC. SHALL BE CEILING MOUNTED. BLUE COLOR KEYED LOW VOLTAGE PLENUM Project Nome and Address B WEST WEST HILL ROAD RATED CABLE SHALL BE INCLUDED. ALL WIRING MUST BE IN CONDUIT t a t o B r: REK BARKHAMSTED, CT 06063 PHONE: 800-2928 z 1 EMT or RIGID EXT. 0 H & M #`2 2 0 $ FAX: 860-738-4123 FLEXIBLE METAL CONDUIT SHALL BE USED ONLY FOR WASHINGTON SQUARE JA2010Jo1>s\10038\us220E45.d.g I WHERE USED TO CONTROL BOTH HEATING AND COOLING, CONNECTIONS INSIDE CASEWORK AND AS THE FINAL 6 THERMOSTATS SHALL PROVIDE A DEADBAND OF AT LEAST 5F WITHIN CONNECTION, FOUR FEET (4'-0") MAXIMUM LENGTH, PORTLAND, D R E G D N to WHICH THE SUPPLY OF HEATING AND COOLING ENERGY TO THE MINIMUM ONE—HALF INCH (1/2") ELECTRICAL TRADE D r o v i n g No. - ti ZONE IS CAPABLE OF BEING SHUT OFF OR REDUCED TO A SIZE TO RECESSED FIXTURES, MOTORS AND LIGHTING CONTROL MINIMUM. ELECTRICAL EQUIPMENT THAT MAY GENERATE VIBRATION THROUGH THE CONDUIT SYSTEM. DETAILS 1 r LIGHTING DETAILS 1 G AS NOTED - E4.5 i C I ID (.3 A L. '3 (3 1 F-- (:, /I -I- 1 0 N S L ' E DIVISION 16 - ELECTRICAL SECTION 16000 F. TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS M. HANGERS 6. FLEXIBLE METAL CONDUIT OR MC TYPE CABLE BASIC ELECTRICAL REQUIREMENTS 1 . WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE 1 . HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE A. FLEXIBLE METAL CONDUIT OR MC TYPE CABLE SHALL BE USED FOR DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE IRON, WIRE, UNISTRUT , C-CLAMPS WITH RETAINING CLIPS, CHANNELS, THE FOLLOWING APPLICATIONS ONLY - 4'-0" MAXIMUM LENGTH: A. NOTE USED AS A MINIMUM FOR THE BASE BID. ANY PROPOSED SUBSTITUTIONS HANGER RODS, ETC. , NECESSARY FOR THE INSTALLATION OF WORK. 1 . FINAL CONNECTIONS TO MOTORS MUST BE PRE-QUALIFIED, LISTED IN THIS CONTRACTOR'S BID AND HAVE A 2 . FINAL CONNECTIONS INTO AND OUT OF THE TRANSFORMER 1 , DRAWINGS AND GENERAL PROVISIONS OF CONTRACT , INCLUDING COST SAVINGS FOR H & M OF AT LEAST $500 PER TYPE OF 2 , HANGERS SHALL BE FASTENED TO BUILDING STEEL , CONCRETE , OR 3, FINAL CONNECTIONS TO VIBRATING EQUIPMENT GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER EQUIPMENT . ADDITIONALLY, ONLY MANUFACTURERS CONSIDERED AS AN MASONRY, BUT NOT TO OTHER CONDUIT , FIXTURES, CEILING SUPPORT 4 . INTER-CONNECTIONS BETWEEN ALL LIGHT FIXTURES (NOT . SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE WIRES OR PIPING. HANGER'S UPPER ATTACHMENT MUST BE SUPPORTED TO INCLUDE HOMERUN FROM FIXTURE OR DEVICE TO DIVISION 16. REVIEWED. ALL SUBSTITUTIONS ARE SUBJECT TO APPROVAL IN WRITING, FROM THE TOP OF THE BAR JOIST . HANGING FROM METAL DECK IS NOT PANELBOARD, WHICH MUST BE EMT OR IMC) THROUGH SHOP DRAWINGS PROCESS, BY H & M'S PERMITTED. WHERE INTERFERENCES OCCUR, IN ORDER TO SUPPORT 5. FINAL CONNECTIONS WHERE EMT OR IMC CONDUIT IS NOT 2. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE CONSTRUCTION MANAGER PRIOR TO ACCEPTANCE . H & M CONDUIT, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR PRACTICAL SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK RESERVES THE RIGHT TO REJECT ANY PROPOSED SUBSTITUTIONS. THE SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE US220 AND IS RESPONSIBLE FOR THE COORDINATION OF THEIR WORK AND THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO WITH ACCESS TO FIRE DAMPERS, VALVES, JUNCTION BOXES, ACCESS WORK OF THEIR SUBCONTRACTOR'S WITH ALL DIVISIONS OF WORK. IT IS REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE . DOORS, OTHER EQUIPMENT SERVICE REQUIREMENTS AND/OR OTHER THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE THEIR TRADES. HANGER TYPES AND INSTALLATION METHODS ARE SUBJECT TO B. FLEXIBLE METAL CONDUIT OR MC TYPE CABLE MUST BE THE SAME WASHINGTON SQUARE SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 2 . ELECTRICAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION LANDLORD CRITERIA. SIZE AS THE IMC OR EMT CONDUIT TO WHICH IT IS CONNECTED. REQUESTS TO H & M'S CONSTRUCTION MANAGER FOR BOTH THE FLEXIBLE METAL CONDUIT AND IT 'S FITTINGS ARE TO BE 9585 S.W. Washington Square 3. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION APPROVAL . SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO END OF SECTION 16000 LISTED FOR GROUNDING. A GREEN GROUNDING CONDUCTOR SUITE H08 AND INSPECTION OF THIS WORK AND THE WORK OF THEIR ALLOW FOUR (4) WORKING DAYS FOR H & M'S SHALL BE INSTALLED. ALL CONNECTORS ARE TO BE OF A NEMA PORTLAND, OR 97223 SUBCONTRACTOR'S WORK TO COMPLY WITH THE C.C. 'S SCHEDULE AND CONSTRUCTION MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR APPROVED TYPE . THE PROJECT COMPLETION DATE . CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP OF THE ELECTRICAL CONTRACTOR'S OFFICE AND C. THE USE OF ROMEX, BX, ARMORED CABLE , ETC. IS NOT PERMITTED. CLASS: RED 4. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO SUB-CONTRACTOR SHOWING THAT THEY HAVE REVIEWED AND DETERMINE CONDITIONS AFFECTING THE WORK, ANY ITEMS WHICH ARE CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE D. CONNECTION TO OUTDOOR EQUIPMENT MUST BE WEATHERPROOF , NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE DIVISION 16 - ELECTRICAL I . E . LIQUIDTIGHT OR SEALTIGHT FLEXIBLE METAL CONDUIT . SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE EXCEPTIONS HAVE BE TAKEN, SECTION 16050 CONTRACTOR'S BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF 7. PROVIDE 210 LB. TENSILE STRENGTH (MIN. ) POLY PULLWIRE IN ALL EMPTY KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH G. GUARANTEE BASIC ELECTRICAL MATERIALS AND METHODS CONDUITS EXCEPT AS NOTED OTHERWISE ON DRAWINGS. ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE 1 , THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK A. SCOPE OF WORK 8. HOME RUNS AND MAIN CONDUIT RUNS ARE TO BE HELD TIGHT TO CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. PROVIDED UNDER THIS CONTRACT AND SHALL MAKE GOOD, REPAIR OR STRUCTURE ABOVE OR AS REQUIRED TO ALLOW PROPER SERVICE ACCESS REPLACE AT HIS OWN EXPENSE , ANY DEFECTIVE WORK, MATERIAL , OR 1 . THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT , AND OTHER TRADES WORK. CONDUIT MUST BE 3 FEET MINIMUM 5. REFER TO RESPONSIBILITY SCHEDULE ON DRAWING COVER SHEET FOR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12- SERVICES, TOOLS, TRANSPORTATION, AND FACILITIES NECESSARY FOR, CLEARANCE ABOVE CEILING. INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MONTHS FROM THE DATE OF ACCEPTANCE ( IN WRITING) OF THE REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, MAY AFFECT BID. INSTALLATION BY H & M'S CONSTRUCTION MANAGER. INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE 9. ALL CONDUITS MUST BE SIZED PER NEC AND LOCAL CODES. EXTENDED WARRANTIES ARE SPECIFIED WITH INDIVIDUAL EQUIPMENT. ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE B. GENERAL REQUIREMENTS SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE , C. OUTLET BOXES 2 . THE OWNER SHALL PROVIDE A COMPLETE 12-MONTH WARRANTY FOR ALL BUT NOT BE LIMITED TO THE FOLLOWING: ' 1 . THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT , PARTS ON EQUIPMENT PROVIDED BY THE OWNER AND ITS VENDORS. 1 . ALL OUTLET BOXES SHALL BE GALVANIZED PRESSED STEEL OF THE °` SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A. A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM INCLUDING THE STANDARD KNOCKOUT TYPE . NO ROUND OUTLET BOXES SHALL BE ',`':, ' NECESSARY TO PROVIDE COMPLETE ELECTRICAL SYSTEMS AS SHOWN ON A COMPLETE WORKING SYSTEM, AND AS SUCH, NO ADDITIONAL MONIES INSTALLATION OF PANELBOARDS, SAFETY AND DISCONNECT PERMITTED, EXCEPT AS SPECIFICALLY NOTED ON DRAWINGS. t r-e' •, ,01` THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED SHOULD BE INCLUDED IN THE BID. SWITCHES, MOTOR STARTERS, LIGHTING CONTACTORS, LIGHTING CONCEALED BOXES SHALL NOT BE LESS THAN 4" SQUARE AND 1-1/2" '' ' BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY CONTROL PANELS, LIGHTS AND TRANSFORMERS. IT IS THE DEEP, WITH PLASTER RING. PLASTER RING IS TO BE SINGLE GANG '� ..,, THE LANDLORD, POWER COMPANY, OWNER OR, THE G.C. SHALL BE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO INCLUDE IN THE OR DOUBLE GANG TO MATCH THE DEVICE(S) INSTALLED IN OUTLET PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE BID FOR PROVIDING SERVICE EQUIPMENT NECESSARY FOR TIE-IN BOX. ., '`f THE ENTIRE INSTALLATION WITH LANDLORD, POWER COMPANY AND THE H. RECORD DRAWINGS TO LANDLORD'S DISTRIBUTION EQUIPMENT OR TO OBTAIN SERVICE C.C. 'S CONSTRUCTION MANAGER AS REQUIRED. FURNISH AND INSTALL 1 . THIS CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS ON THE FROM LOCAL UTILITY COMPANY. 2. ALL KNOCKOUT BOXES, UPON WHICH LIGHTING FIXTURES ARE TO BE EQUIPMENT THAT IS RATED FOR AVAILABLE FAULT CURRENT LEVELS. 4 JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: ' SHALL BE EQUIPPED WITH 3/8" FIXTURE STUDS. B. CONTRACTOR MUST ALSO INCLUDE IN BID ALL NECESSARY INSTALLED FURNISH AND INSTALL "CABLE LIMITERS" IF NECESSARY TO LIMIT FAULT MATERIALS REQUIRED TO COMPLETE THE SYSTEM INCLUDING, BUT CURRENT. FIELD VERIFY THE EXACT TYPE , SIZE , LOCATION, A LOCATION OF JUNCTION BOXES AND RECEPTACLES. NOT LIMITED TO, FEEDERS, BRANCH CIRCUITS, JUNCTION BOXES, 3. EXTERIOR BOXES SHALL BE CAST RUST-RESISTING METAL WITH REQUIREMENTS, ETC. OF EXISTING POWER AND TELEPHONE FACILITIES g• REVISIONS, ADDENDUMS, AND CHANGE ORDERS. OUTLET BOXES, WIRING DEVICES, COVERPLATES, CONDUITS, ETC. WEATHERPROOF NEMA 3R GASKETED COVERS. PRIOR TO SUBMISSION OF BID. C. METERING AND CURRENT TRANSFORMERS AS REQUIRED BY C. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD 4. INSTALL BOXES RIGIDLY FROM BUILDING STRUCTURE AND SUPPORT CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND DRAWINGS, THE OWNER, UTILITY COMPANY, AND/OR LANDLORD. INDEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE 2 . UNLESS SPECIFICALLY NOTED OTHERWISE , MATERIALS, PRODUCTS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. D. THE WIRING OF MECHANICAL EQUIPMENT AS OUTLINED ON THE EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF , SHALL BE NEW, BID SET DRAWINGS AND IN THE SPECIFICATIONS. WORK SHALL BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF FLOORS, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN INCLUDE WIRING OF ALL STARTERS, DISCONNECTS, AND POWER CEILINGS, WALLS ETC. ALL OUTLET BOXES TO BE PROVIDED WITH 2 . AT COMPLETION OF PROJECT AND BEFORE FINAL APPROVAL , THE CADDY "QUICK-MOUNT BOX SUPPORT" TO MINIMIZE THE DEFLECTION CONFORMITY WITH REQUIREMENTS OF THE NATIONAL ELECTRICAL WIRING OF MECHANICAL EQUIPMENT EXCEPT AS SPECIFICALLY THAT OCCURS WHEN PLUGGING/UNPLUGGING INTO THESE DEVICES. H B K CODE , STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT . CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND NOTED OTHERWISE . CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON, ONE E COPY OF DRAWINGS STAMPED "DO NOT REMOVE" SHALL BE PLACED IN E . INSTALLATION OF LIGHT FIXTURES AND LAMPS AS SHOWN ON THE 3. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT AS-BUILT DRAWING TUBE AND LOCATED BY ELECTRICAL PANELS IN THE DRAWINGS INCLUDING ALL DEVICES, EQUIPMENT, ETC. REQUIRED 5. UNLESS OTHERWISE NOTED ON DRAWINGS OR OTHERWISE REQUIRED BY CONSULTANTS, LTD EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR I N ONE SHALL TENANT SPACE . FOR MOUNTING. THE NATIONAL ELECTRICAL CODE , HANDICAP CODES OR LOCAL CODES, Mechanical do Eiectricoi Design Services BE PROVIDED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. F . A COMPLETE CONDUIT SYSTEM FOR TELEPHONE/DATA INCLUDING OUTLET HEIGHTS SHALL BE AS FOLLOWS: ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS TERMINAL BOARD, BRANCH CONDUITS, OUTLET BOXES, PULL 48"NOR CALLED FOR I N THE SPECIFICATIONS, BUT WHICH I S OBVIOUSLY I. DISCREPANCIES IN DOCUMENTS WIRES, GROUND CONDUCTORS, COVER PLATES, ETC. UNLESS A. SWITCH HEIGHT 48 FROM FINISHED FLOOR TO CENTERLINE OF 171 Charring Cross Drive S. NECESSARY TO COMPLETE THE WORK OR WHICH IS USUALLY INCLUDED SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. OUTLET . suitete IN WORK OF SIMILAR CHARACTER, SHALL BE PROVIDED AS PART OF 1 . DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC G. A COMPLETE EMERGENCY AND EXIT LIGHTING SYSTEM AS SHOWN B. CONVENIENCE OUTLETS: SALES & NON-SALES: 18" FROM FINISHED Westerville, Ohio 43081 CONTRACT AT NO ADDITIONAL COST TO CONTRACT . AND INDICATE THE GENERAL LOCATION AND INTENT OF THE ELECTRICAL ON THE DRAWINGS. FLOOR TO CENTERLINE OF OUTLET 614,882.1199 SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, H. TEMPORARY ELECTRIC SERVICE AS INDICATED IN THE C. TELEPHONE OUTLETS SHALL BE LOCATED AS NOTED ON FAX 614,882,1857 4. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE SPECIFICATIONS, INCLUDING ITS REMOVAL . DRAWINGS. EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE H & M IN WRITING PRIOR OR TO SUBMITTAL OF BID. I . FINAL CONNECTIONS TO ALL ILLUMINATED SIGNS, CORNICE OTHERWISE , H & M S CONSTRUCTION MANAGER'S CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE LIGHTING, CASE LIGHTING, ETC. AS SHOWN ON DRAWINGS. D. JUNCTION AND PULL BOXES INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. J .. !NSTALLAT I ON AND WIRING OF SPEAKERS, AMPLIFIERS, CONDUIT 1 . THE PLANS INDICATE ONLY SCHEMATIC ROUTINGS FOR CONDO I T RUNS RUNS. Drawings and written material appearing herein constitute original DESCRIBED ON THESE DRAWINGS, UNLESS NOTED OTHERWISE . AND FINAL CONNECTIONS FOR SOUND SYSTEM AS SHOWN ON THIS CONTRACTOR SHALL FURNISH AND INSTALL ADDITIONAL BOXES and unpublished work of the Architect and may not be duplicated, 2. THE LOCATION OF OUTLETS AND EQUIPMENT SHOWN ON THE DRAWINGS DRAWINGS. WHERE REQUIRED BY FIELD CONDITIONS OR BY CODE AND SIZED AS used or disclosed without written consent of the Architect 5. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ARE APPROXIMATE AND SCHEMATIC IN NATURE . H & M K. SMOKE/FIRE ALARM WIRING, DEVICES AND CONDUIT , AS SHOWN OR ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIRING. SHALL HAVE THE RIGHT TO CLARIFY LOCATION OF ANY OUTLETS OR DESCRIBED ON DRAWINGS OR AS NECESSARY TO MEET LANDLORD, REQUIRED. &I BH ARCHITECT - 2010 THIS CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH OTHER STATE , LOCAL , INSURANCE AND FIRE DEPARTMENT TRADES AND FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL FIXTURES AND ASSOCIATED WIRING BEFORE THEY ARE INSTALLED REQUIREMENTS. 2 . BOXES AND COVERS SHALL BE GALVANIZED STEEL OF CODE GAUGE SIZE . EQUIPMENT. WITHOUT ADDITIONAL COST . pAOC L . INSTALLATION OF CONDUITS FOR HVAC CONTROL EQUIPMENT J. PHASING REQUIREMENTS WHERE PLENUM RATED CABLES ARE NOT PERMITTED. 3. INSTALL BOXES RIGIDLY SUPPORTED FROM THE BUILDING STRUCTURE No.o. 0 a t e Issue s s u e 6. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING AND SUPPORTED INDEPENDENT OF THE CONDUIT SYSTEM. AND PATCHING REQUIRED FOR ANY WORK UNDER THIS DIVISION. 1 . FOR ANY PHASED STORE CONSTRUCTION, THIS CONTRACTOR IS TO 2 . WORK NOT INCLUDED. THE FOLLOWING ITEMS OF ELECTRICAL 05/28/10 100% SET CUTTING SHALL HAVE PRIOR APPROVAL BY THE C.C. 'S CONSTRUCTION CONSTRUCTION ARE NOT INCLUDED IN THIS CONTRACT: 4. ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN MANAGER AND THE LANDLORD. PATCHING IS TO MATCH SURROUNDING INCLUDE IN THE BID ALL NECESSARY ELECTRICAL SERVICE CHANGES INACCESSIBLE LOCATIONS, THE USE OF JUNCTION BOXES ABOVE 05/28/10 VT PACKAGE SURFACES. REQUIRED TO KEEP THE OPERATING PHASE OF THE STORE 'S ELECTRIC A. 24 VOLT TEMPERATURE CONTROL WIRING UNLESS NOTED DRYWALL CEILINGS SHOULD BE IN LOCATIONS NEAR ACCESS FRAMES SERVICE I N OPERATION, CONTRACTOR MUST SCHEDULE WITH I TH USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS 07/02/10 1007 COMPLETE SET H & M'S CONSTRUCTION MANAGER AND LANDLORD ( IN WRITING) ONE OTHERWISE . 7. THE ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL WEEK PRIOR TO ANY SHUT DOWN OF THE POS, CASH REGISTERS, B. TELEPHONE INSTRUMENTS AND WIRING UNLESS NOTED LOCATED ON PLANS. 07/28/10 LANDLORD SET CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM, OTHERWISE . ELECTRICAL , TELEPHONE OR FIRE ALARM SYSTEMS. ADVISE H & M AT TIME OF BID IF ANY CONFLICTS EXIST. C. DATA LINES WIRING UNLESS NOTED OTHERWISE . 5. JUNCTION AND PULL BOXES MUST BE LABELED WITH PANELBOARD AND 08/13/10 PERMIT BID SET C. TEMPORARY LIGHT AND POWER CIRCUIT NUMBER IDENTIFICATION AND/OR SYSTEM TYPE ON COVER. K. DEMOLITION 3. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE 1 . THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL TEMPORARY ARCHITECTURAL , STRUCTURAL , FIRE PROTECTION, MECHANICAL AND E. WIRING WIRING AND RELATED GROUND FAULT INTERRUPTION PROTECTION FOR 1 • PLUMBING PLANS, SHOP DRAWINGS AND SPECIFICATIONS TO SEQUENCE , LIGHT AND POWER FOR ALL CONTRACTORS AND IS RESPONSIBLE FOR IT 'S THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF COORDINATE , AND INTEGRATE THE VARIOUS ELEMENTS OF THE 1 . CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS SHALL BE COPPER REMOVAL . THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED ELECTRICAL SYSTEM, MATERIALS AND EQUIPMENT WITH OTHER AND THE AWG SIZE AND TYPE AS SHOWN ON DRAWINGS. THE BY THE G.C. . COORDINATE WITH THE G.C. ANY EXISTING EQUIPMENT CONDUCTORS SHALL BE 600 VOLT INSULATION, TYPE THW, THWN OR REQUIRED TO BE LEFT INTACT AND OPERATIONAL FOR REUSE . CONTRACTORS TO AVOID INTERFERENCES AND CONFLICTS. 2 . THE ELECTRICAL CONTRACTOR SHALL PAY FOR ALL ELECTRICITY PRIOR THHN. TO STORE MERCHANDISING AND INCLUDE COST IN BID. 2. THIS CONTRACTOR SHALL VERIFY SCOPE OF WORK WITH THE G.C. FOR B. CONDUIT. THE REMOVAL OF ALL EXISTING CONDUIT , FIRE ALARM SYSTEM, 2. MINIMUM WIRE SIZE - 20 AMP BRANCH CIRCUITS SHALL BE #12 AWG D. CODES 1 . THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUITS UNLESS OTHERWISE NOTED ON DRAWINGS OR REQUIRED BY N.E .C. . SWITCHGEAR, PITCH POCKETS AND EQUIPMENT ETC. UNLESS INCLUDING BUT NOT LIMITED TO, LIGHTING, SPECIFICALLY NOTED OTHERWISE . CONTRACTOR MUST VERIFY WITH SERVING ALL EQUIPMENT , 1 . ALL WORK SHALL BE PERFORMED IN A NEAT AND PROFESSIONAL RECEPTACLES, HEATING, AIR CONDITIONING, PLUMBING EQUIPMENT, 3. ON ALL 20 AMP BRANCH CIRCUITS, CONDUCTORS LARGER THAN #10 AWG THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT , CONDUIT AND MANNER AND CONFORM TO THE LATEST ADOPTED EDITION OF THE SPEAKERS, AND ELECTRICAL EQUIPMENT. SHALL BE REDUCED TO #10 AWG WITHIN 10 FEET OF PANELBOARD AND SWITCHGEAR PRIOR TO REMOVAL , PITCH POCKETS SHALL BE REMOVED TELEPHONE , DATA, NATIONAL ELECTRICAL CODE , LANDLORD'S CRITERIA, THE STATE 'S, DEVICE IN JUNCTION BOXES ON RATED TERMINAL STRIPS. AND THE ROOF PATCHED, AS REQUIRED BY THE LANDLORD. ALL COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND 2 . ALL CONDUITS SHALL BE GALVANIZED IMC OR EMT UNLESS OTHERWISE HEALTH CODES, NFPA CODES, ENERGY CODES, AND ALL OTHER EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO SPECIFIED IN SPECIFICATIONS OR ON DRAWINGS. ALL CONDUIT IS TO BE 4, CONDUCTORS MAY BE STRANDED FOR SIZES #10 AWG AND LARGER. THE NEW WORK MUST BE REMOVED AND ROOF/WALL/FLOOR APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL PATCHED/REPAIRED TO LIKE NEW CONDITION, EXISTING ABANDONED UL LABELED. EMT CONNECTORS SHALL BE STEEL COMPRESSION OR SET CONDUCTORS SIZE #12 SHALL BE SOLID (NOT STRANDED) . INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, SCREW TYPE. CONDUIT UNDER SLAB ON GRADE SHALL BE RIGID STEEL , CONDUIT OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE , OR 5. ALUMINUM CONDUCTORS ARE NOT PERMITTED. CONDUCTOR AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES OR SCHEDULE 40 PVC WITH RIGID STEEL ELLS WHERE PERMITTED BY REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT OTHERWISE INACCESSIBLE , ARE TO BE CUT OFF AND SEALED BELOW OR LANDLORD OR CODE . CONNECTION MUST BE PER MANUFACTURER'S REQUIREMENTS. INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN CONTRACTOR MUST ADVISE H & M'S CONSTRUCTION ITEM IN THE BID. AFTER CONTRACT IS ISSUED, THIS PROJECT , IF REQUIRED BY LANDLORD OR CODES, ABANDONED MANAGER WHEN USED. NO ADDITIONAL COST DUE 3. MINIMUM SIZE OF CONDUIT SHALL BE 1/2" FOR INDIVIDUAL LIGHTING TO CODE ISSUES SHALL BE REIMBURSED BY THE OWNER TO THE CONDUIT MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM EXTENT OF FIXTURE CONNECTIONS OR TO INDIVIDUAL LIGHT SWITCHES ( IF CONTRACTOR. DEMOLITION WITH THE G.C. PRIOR TO BID AND INCLUDE COSTS IN BID AS ACCEPTABLE BY THE LANDLORD AND LOCAL CODE OFFICIALS) AND 3/4" 6. ALL WIRING SHALL BE IN CONDUIT , UNLESS SPECIFICALLY NOTED 4 DIRECTED BY THE G.C. . OTHERWISE IE • LOW VOLTAGE PLENUM RATED WIRE FOR ALL OTHER LOCATIONS. IF HVAC CONTROL WIRING IS REQUIRED TO ) • Project No. 44122/10038 E. LICENSES, PERMITS. INSPECTIONS & FEES L. SLEEVES BE RUN IN CONDUIT, IT SHALL BE A MINIMUM OF 3/4" , UNLESS NOTED 7, THE USE OF SHARED NEUTRALS I S REQUIRED FOR LIGHTING C i RCU I TS I OTHERWISE ON DRAWINGS. ALL IN/UNDER FLOOR CONDUIT SHALL BE OF AND SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL 1 . THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, 1 . THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR MINIMUM 3/4" SIZE . ELECTRICAL CODE AND LOCAL CODES. ALL OTHER EQUIPMENT INSPECTIONS, AND FEES REQUIRED OR RELATED TO HIS WORK. FACILITIES IN THE INSTALLATION, EACH SLEEVE SHALL EXTEND Scale AS NOTED 4. SUPPORT ALL CONDUIT, INCLUDING SEISMIC AND SWAY BRACING, IN REQUIRING A NEUTRAL CONDUCTOR SHALL HAVE A DEDICATED FULL 2 . FURNISH TO H & M'S CONSTRUCTION MANAGER ALL THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE ACCORDANCE WITH THE N.E.C. AND LOCAL CODES AS APPLICABLE . SIZE NEUTRAL . CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE OroreBr: REK COMPLETION OF PROJECT. FLOOR, WHICH SHALL EXTEND 4" ABOVE THE FLOOR. 8. THE USE OF ROMEX, BX, ARMORED CABLE , ETC IS NOT PERMITTED 5. GENERALLY, ALL CONDUIT SHALL BE CONCEALED EXCEPT FOR ETC. PERMITTED. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND/OR UNFINISHED AREAS, SUCH AS EQUIPMENT ROOMS. EXPOSED CONDUIT FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE , SILICONE "RTV" SHALL BE CONSTRUCTION TONLY AS NOTED ON PLAN AND AS APPROVED BY THE 9. WIRE CONNECTORS SHALL "SCOTCH LOCK" FOR #8 AWG WIRE AND " " FIRE SEALANTS OR EQUAL , AS TO RETAIN THEIR H & M S CONSTRUCTION MANAGER, PAINTING OF SMALLER AND SHALL BE T & B "LOCKTIGHT" FOR #6 AWG AND LARGER. .S FIRE RATING. RCOORDINATE WITH SMALL EMANAGER OFOR TYPE OF FIRE CONDUITS, NOTED ON DRAWINGS OR SPECIFICATIONS WILL BE BY THE JA2010 ,iobs\10038\tJS220E30.d•q A CAULKING ALLOWED. G.C. . 0 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS AND PARTITIONS Droving No. R SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH ELECTRICAL a EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL CONDUIT , SLEEVES SHALL BE SPECIFICATIONS ' NO 22 U.S.G. GALVANIZED STEEL MINIMUM. I 3 ELE TRI AL SPECIFI ATI N NONE 1 M C C C O S _ .1::) ELEcTRIc . L soEcinc A TioNs 10. ALL WIRING TO BE COLOR-CODED AS FOLLOWS: 6. FOR PANEL FEEDERS, BOND THE GROUNDING CONDUCTOR TO THE N. LIGHTING CONTROLS P. TESTS AND ADJUSTMENTS CONDUIT, WHERE ENTERING AND LEAVING THE CONDUIT . THE 120/208 VOLT SYSTEM 277/480 VOLT SYSTEM GROUNDING CONDUCTOR SHALL BE COPPER WITH GREEN 1 . THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL 1 . ALL CONNECTIONS AT PANELS AND SWITCHES ARE TO BE MADE , ALL NEUTRAL: WHITE GRAY IDENTIFICATION AND SIZED PER N.E .C. . LIGHTING CONTACTORS AS INDICATED ON DRAWINGS. THE ELECTRICAL SPLICES COMPLETE , ALL FUSES IN PLACE , AND ALL CIRCUITS PHASE A OR L1 : BLACK YELLOW CONTRACTOR SHALL BE RESPONSIBLE TO INSTALL THE SYSTEM AND CONTINUOUS FROM POINT OF SERVICE CONNECTION TO ITS FINAL PHASE B OR L2: RED ORANGE 7, ALL ENCLOSURES AND NON-CURRENT CARRYING METAL PARTS ARE TO PULL ALL WIRES AS DETAILED ON THESE DRAWINGS AND TO INSTALL DESTINATION, AND ALL COVERS AND PLATES INSTALLED PRIOR TO THE PHASE C OR L3: BLUE BROWN BE GROUNDED. CONDUIT SYSTEM IS TO BE ELECTRICALLY CONTINUOUS. CIRCUITING EXACTLY AS DIAGRAMMED ON THE LIGHTING PLAN TIME OF FINAL INSPECTION BY H & M'S CONSTRUCTION MANAGER, GROUND: GREEN GREEN ALL LOCKNUTS MUST CUT THROUGH ENAMELED OR PAINTED SURFACES DRAWINGS. VARIATIONS TO THE CIRCUITING ARE NOT ALLOWED ISOLATED GROUND: GREEN W/ YELLOW GREEN W/YELLOW ON ENCLOSURES WHERE ENCLOSURES AND NON- CURRENT CARRYING WITHOUT PRIOR WRITTEN APPROVAL BY H & M'S CONSTRUCTION 2 . UPON COMPLETION OF THE WORK, ALL PARTS OF THE ELECTRICAL TRACER TRACER METAL PARTS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING MANAGER, INSTALLATION SHALL BE TESTED AND PROVED FREE OF UNWANTED JUMPERS WITH APPROVED CLAMPS. ALL GROUND CLAMPS SHALL BE GROUNDS AND OTHER DEFECTS. F. WIRING DEVICES "PENN-UNION" "GPL" TYPE . 2. TIME CLOCK SHALL BE A PROGRAMMABLE 7-DAY, 24-HOUR ELECTRONIC TYPE WITH BATTERY BACKUP AS MANUFACTURED BY TORK, RAINBIRD 3. ALL OVERLOAD DEVICES, INCLUDING EQUIPMENT FURNISHED UNDER 1 . THIS CONTRACTOR SHALL FURNISH AND INSTALL SWITCHES AND K. DRY TYPE TRANSFORMERS OR INTERMATIC. TIME CLOCKS SHALL BE WIRED TO CONTROL LIGHTING OTHER CONTRACTS, SHALL BE SET AND ADJUSTED TO SUIT THE LOAD US220 RECEPTACLES, UNLESS NOTED OTHERWISE , AS NECESSARY FOR A AND HVAC SYSTEM AS INDICATED ON DRAWINGS. CONDITIONS. WASHINGTON SQUARE COMPLETE INSTALLATION. COLOR OF DEVICES AND PLATES SHALL BE 1 . TRANSFORMERS WHICH ARE NOT PAD MOUNTED SHALL BE SECURELY WHITE AT PAINTED WALLS, IVORY WHEN INSTALLED IN MERCHANDISING MOUNTED FROM THE BUILDING STRUCTURE , REINFORCED WALLS, OR AS O. DOOR BUZZER AND PUSHBUTTON SYSTEM 4. TEST AND MAKE CORRECTIONS/ADJUSTMENTS FOR PHASE BALANCING. FIXTURES AND ORANGE FOR " I .G. " RECEPTACLES UNLESS NOTED NOTED ON DRAWINGS. USE ADDITIONAL VIBRATION ISOLATORS AT 9585 S.W. Washington Square OTHERWISE . THE DEVICES SHALL BE OF THE TYPES AND RATINGS LISTED POINTS OF MOUNTING TO CUT VIBRATION NOISES. USE FLEXIBLE 1 . PROVIDE A COMPLETE AND OPERATING DOOR BUZZER SYSTEM WITH ALL 5. THIS CONTRACTOR IS TO BALANCE THE VOLTAGE LEAVING THE STEP- SUITE H08 BY LEVITON OR PASS & SEYMOUR. WEATHERPROOF GFI RECEPTACLES METALLIC CONDUIT WITH GROUNDING BUSHING FOR PRIMARY AND NECESSARY ACCESSORIES, TRANSFORMERS AND WIRING. DOWN TRANSFORMER TO PROVIDE A SECONDARY VOLTAGE OF 120 VOLTS SHALL BE INSTALLED WHERE SHOWN ON DRAWINGS OR AS REQUIRED BY SECONDARY CONNECTIONS TO TRANSFORMER. TRANSFORMERS SHALL MINIMUM TO 125 VOLTS MAXIMUM BY ADJUSTING THE TRANSFORMER PORTLAND, OR 97223 CODE . BE LOCATED, SET , MOUNTED AND CONNECTED IN SUCH A MANNER AS TO 2 . BUZZER(S) SHALL BE MOUNTED 8'-0" A. F .F . IN NON-SALES, IN TAPS ONCE ALL THE FINAL CONNECTIONS HAVE BEEN MADE TO THE LOW KEEP NOISE LEVELS WITHIN THE SURROUNDING AMBIENT NOISE LEVELS MEZZANINE AREA ( IF SPACE CONTAINS ONE) AND 2'-0" A.F .F. VOLTAGE PANELBOARD. PROVIDE FINAL BALANCE REPORT TO CLASS: RED SINGLE POLE SWITCHES: 20AMP - 120/277V: HUBBELL "HBL-1221 " AND MAINTAIN ALL CODE REQUIRED CLEARANCES. UNDER CASH WRAP COUNTER. H & M'S CONSTRUCTION MANAGER AT TIME OF PUNCH-OUT . THREE WAY SWITCHES: 20AMP - 120/277V: HUBBELL "HBL-1223" DUPLEX RECEPTACLES: 20AMP - 125V: HUBBELL "5362" 2 . TRANSFORMER SHALL BE QUIET TYPE CONSTRUCTION AND HAVE SIX (6) 3. PUSHBUTTON SHALL BE MOUNTED AT 4'-0" A. F .F . . O. CLEANING ISOLATED GROUND RECEPTACLES: 20AMP - 125V: HUBBELL " IG5362" 2-1/2% TAPS, TWO (2) TAPS ABOVE AND FOUR (4) TAPS BELOW NORMAL GROUND FAULT CIRCUIT INTERRUPTING RECEPTACLES: PRIMARY RATING. 4. TRANSFORMER SHALL BE MOUNTED AT 8'-0" A.F.F . AND CONNECTED 1 . AT THE END OF THE PROJECT , THIS CONTRACTOR SHALL CLEAN ALL 20AMP - 125V: HUBBELL "GF5352" TO CIRCUIT AS SHOWN. EQUIPMENT , INCLUDING LIGHT FIXTURES, TO THE SATISFACTION OF CLOCK RECEPTACLE : HUBBELL "5235" 3. TRANSFORMER SHALL NOT CONTAIN ANY "PCB'S" (POLYCHLORINATED H & M. ALL DUST, DIRT , DEBRIS, AND FOREIGN MATTER SHALL BE BIPHENYLS) . FROM ALL EQUIPMENT. 2 . CASH REGISTER RECEPTACLE COVER PLATE SHALL BE ENGRAVED "FOR CASH REGISTERS ONLY" . 4 . MANUFACTURER SHALL BE SQUARE D, GENERAL ELECTRIC OR CUTLER END OF SECTION 16050 " HAMMER. 3. ALL DEVICE COVER PLATES SHALL BE PASS AND SEYMOUR SERIES RP BY EAGLE ELECTRIC MFG.CO. . L. PANELBOARDS (717-- ..G. HEATING, VENTILATING & AIR CONDITIONING, PLUMBING, AND FIRE 141f7/4111 '''' : PROTECTION WIRING 1 . ALL PANELBOARDS SHALL BE FACTORY ASSEMBLED OF THE BOLTED j. CIRCUIT BREAKER TYPE WITH SOLID COPPER BUSSING, FULL SIZED gt/y-zoya ' ' 1 . ELECTRICAL CONTRACTOR SHALL REFER TO MECHANICAL AND COPPER NEUTRAL , 100% GROUND BUSSING, AND OVERALL , TEMPERATURE CONTROL DRAWINGS FOR ADDITIONAL ELECTRICAL HINGED/LOCKABLE DOOR. ALL CIRCUIT BREAKERS SHALL BE OF THE WORK TO BE INCLUDED IN HIS BID. QUICK-MAKE AND QUICK-BREAK DESIGN, THERMAL-MAGNETIC TYPE , TECHNOLOGY RESPONSIBILITY SCHEDULE ELECTRICAL RESPONSIBILITY SCHEDULE :yah. bM1 /1 TRIP FREE AND TRIP-INDICATING. ALL PANELS SHALL BE DEAD FRONT 2 . ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL POWER AND FLUSH OR SURFACE MOUNTED AS SHOWN. ALL LIGHTING BRANCH ITEM TECHNOLOGY ELECTRICAL FURNISHED BY INSTALLED BY WIRING, LINE VOLTAGE WIRING, AND LINE VOLTAGE CONTROL WIRING CIRCUIT BREAKERS SHALL BE SWITCHING DUTY RATED AND LABELED CONTRACTOR CONTRACTOR INDICATED UNDER THE HEATING, VENTILATION AND AIR CONDITIONING, "SWD" . ALL CIRCUIT BREAKERS FEEDING HEATING, AIR CONDITIONING PLUMBING AND FIRE PROTECTION SPECIFICATIONS AND DRAWINGS. THIS AND REFRIGERATION EQUIPMENT SHALL BE "HACR" RATED. COMPLETE CONDUIT PATHWAY SYSTEM INCLUDING CONTRACTOR SHALL ALSO FURNISH AND INSTALL ALL BUT NOT L I M I TED TO; CONDUIT, MANHOLES, HAND • 0 ,°� o 0 x° o REMARKS o INTERCONNECTING LINE VOLTAGE WIRING BETWEEN RELAYS AND 2. CONTRACTOR SHALL FURNISH AND INSTALL A TYPEWRITTEN DIRECTORY HOLES, JUNCTION BOXES, OUTLET BOXES, PLASTER 0 M • " o z SWITCHES AS REQUIRED. CARD OF THE CIRCUITS AND PLACE IN PANEL DOOR. RINGS, ETC. ITEM w zz i I w zz I v Q 0 W X W J I 0 I- W J 0 I-- Z W 3. ELECTRICAL CONTRACTOR I S RESPONSIBLE FOR FURNISHING AND 3. ALL PANELBOARDS PHASE AMPERAGE SHALL BE BALANCED TO WITHIN 7 FIRE-RATED PAINTED PLYWOOD BACKBOARDS FOR MAIN OVERCURRENT DEVICE IN LANDLORD'S VERIFY INSTALLING CONDUIT FOR HVAC CONTROL WIRING WHERE REQUIRED BY PERCENT MAX. TO MIN. . REARRANGE NON-LIGHTING BRANCH CIRCUITS TECHNOLOGY USE. • ELECTRIC ROOM 0 0 O IN FIELD CODE TO BE IN CONDUIT , REFER TO PLANS FOR REQUIREMENTS AND AS REQUIRED AND NOTE CHANGES ON RECORD DRAWINGS. LIGHTING SIZE . PANEL CIRCUIT BREAKERS MUST BE INSTALLED AND WIRED EXACTLY AS ELECTRICAL METER IN LANDLORD'S ELECTRIC RM 0 0 O VERIFY SHOWN ON DRAW I NGS. TECHNOLOGY GROUNDING SYSTEM INCLUDING BUT IN FIELD H. SAFETY AND DISCONNECT SWITCHES NOT L I M I TED TO: GROUND CONDUCTORS, COPPER 2 VERIFY " FIELD- BUS BARS AND ASSOCIATED HARDWARE 0 SERVICE ENTRANCE CONDUIT(S) TO LEASE SPACE 0 0 IN FIELD H B K 4. PANELBOARDS MUST BE MOUNTED ON MINI MUM 3/4 A/D PLYWOOD AND REQUIRED FOR A COMPLETE GROUNDING SYSTEM. i - 1 . SAFETY AND DISCONNECT SWITCHES SHALL BE HEAVY DUTY TYPE , PAINTED I N A COLOR TO MATCH THE SURROUNDING WALLS OR A COLOR SERVICE ENTRANCE CONDUIT(S) FROM STUB IN O O 0 QUICK-MAKE , QUICK-BREAK FUSED OR NON-FUSIBLE WITH RATINGS AND AS REQUIRED DIRECTED BY ARCHITECT. PLYWOOD SHALL EXTEND 1 LEASE SPACE TO UTILIZATION EQUIPMENT CONSULTANTS, LTD SIZES AS NOTED ON PLANS AND REQU I RED BY CODES. FOOT MINI MUM BEYOND EDGE OF EQUIPMENT. 1" SLEEVES AND F I RESTOPP I NG WHERE REQUIRED. z VERIFY Mechanical & Electrical Design Services SERVICE ENTRANCE FEEDER(S) TO LEASE SPACE 0 a C- IN FIELD 2 . SWITCHES SHALL BE WEATHERPROOF IN OUTDOOR LOCATIONS OR AS 5. PANELBOARDS SHALL HAVE A MINIMUM SHORT CIRCUIT CURRENT - REQUIRED BY LOCAL CODES. DISCONNECT SWITCHES THAT ARE RATING AND LUG CONNECTIONS AS FOLLOWS: DISTRIBUTION PANELBOARDS CO O 0 INSTALLED AT HEATING, VENTILATING AND AIR CONDITIONING (HVAC) 171 Charring Cross Drive S. ( ) CONDUIT PULL STRINGS (SEE NOTE 1 ) STEP DOWN TRANSFORMERS AND MOUNTING Suite 16 EQUIPMENT SHALL BE FUSED I F NOT PROTECTED WITH A "HACR" 120/208 VOLT PANELBOARDS: 10,000 A. I .C. - O O 0 Westerville, Ohio 43081 BREAKER I N ACCORDANCE WITH THE EQUIPMENT 'S NAMEPLATE AND 277/480 VOLT PANELBOARDS: 14,000 A, I .C. ACCESSORIES (AS REQUIRED) , 614,882.1199 MANUFACTURER'S REQUIREMENTS PER THE NATIONAL ELECTR I CAL BONDING OF ALL TECHNOLOGY EQUIPMENT FAX 614,882,1857 LIGHTING FIXTURES AND LAMPS 0 0 0 CODE , STATE AND LOCAL CODES. VERIFY ACTUAL A. I .C. SHORT CIRCUIT CURRENT REQUIREMENTS WITH !NCLUD I NG BUT NOT L I M I TED TO: BONDING • THE LANDLORD OR UTILITY COMPANY PRIOR TO ORDERING EQUIPMENT . JUMPERS AND ASSOCIATED HARDWARE. WIRED BY ELEC. 3. AT SERVICE ENTRANCE , DISCONNECT SHALL BEAR THE MANUFACTURER'S , TOILET EXHAUST FAN(S) 0 0 CONTR. LABEL INDICATING THE EQUIPMENT IS UL RATED FOR APPLICATION IN 6. EQUIPMENT SHALL BE SQUARE D POWERLINK G3 SYSTEM. GENERAL BONDING OF ALL TECHNOLOGY EQUIPMENT ' - ACCORDANCE WITH ALL CODES. CONTRACTOR TO PURCHASE FROM OWNER SUPPLIER. NO SUBSTITUTIONS INCLUDING BUT NOT LIMITED TO: BONDING • • RECEPTACLES: SALES AREA 0 0 Drawings and written moltriol appearing herein constitute original PERMITTED. FOR PRICING AND ORDERING INFORMATION CONTACT: JUMPERS AND ASSOCIATED HARDWARE. , . 1 and unpublished work of the Architect and may not be duplicoted, 4 . SQUARE D CLASS 2510 MANUAL MOTOR STARTERS, LESS OVERLOAD FRED SCHNEIDER RECEPTACLES: NON-SALES AREA 0 0 used or disclosed without written consent of the Architect PROTECTION HEATERS, ARE TO BE USED AS A DISCONNECTING MEANS DIRECTOR OF NATIONAL ACCOUNTS cMO H ARCHITECT - 2010 PROVIDE AND INSTALL ALL CAT-5E DATA CABLING • Q ONLY WHERE INDICATED ON DRAW I NGS FOR FRACTIONAL HORSEPOWER LIGHT OPTIONS AND 25-PAIR TELEPHONE CABLING. POWER WIRING TO HVAC EQUIPMENT 0 0 MOTORS ABOVE 1-1/2 HP AT 120 VOLTS AND 2 HP AT 240 VOLTS THAT DO 1251 METROPOLITAN AVE . . NOT REQUIRE AUXILIARY CONTROL . WEST DEPTFORD, NJ 08066 LIGHTING CONTROL SYSTEM O O 0 A 0 C 856-853-9922 (EXT. 304) PROVIDE AND INSTALL ALL DATA HARDWARE 5. MANUFACTURER SHALL BE SQUARE D, GENERAL ELECTRIC OR C U T L E R I N C L U D I N G BUT NOT LIMITED TO: DATA/PHONE No. D o l e I s s u e f r ed.schne I der®ccoper-e I ect r I c.cam HAMMER JACKS, PATCH PANELS, FACE PLATES, • POWER WIRING TO "CASHWRAP" 0 0 TECHNOLOGY CABINETS, J-HOOKS, CABLE TIES, . . 05/28/10 100% SET M. LIGHTING FIXTURES AND LAMPS WIRE MANAGEMENT AND M I SC. RACK EQUIPMENT TO POWER WIRING AND CONDUIT FOR I. MOTOR STARTERS MEET SPEC I F I CATIONS. SENSORMATIC EQUIPMENT O O 05/28/10 VT PACKAGE 1 • THIS CONTRACTOR SHALL INSTALL ALL LIGHTING FIXTURES AND LAMPS 07/02/10 100 COMPLETE SET 1 . MAGNETIC MOTOR STARTERS SHALL BE PROVIDED WITH RESET TYPE AS SHOWN ON THE DRAWINGS. LIGHTING FIXTURES AND LAMPS ARE POWER WIRING FOR ROLLING GRILLE O O OVERLOADS THAT CLOSELY MATCH MOTOR NAMEPLATE RATING AND SUPPLIED BY THE OWNER, UNLESS NOTED OTHERWISE . CONTRACTOR I S FIELD QUALITY CONTROL - TESTING AND . 07/28/10 LANDLORD SET SHALL BE ELECTRICALLY HELD (MINIMUM SIZE #1 I N A NEMA 1 TO REPLACE ALL NON-WORKING LAMPS PRIOR TO MERCHANDISE DATE CERT I F I CAT ION. DELIVERY BUZZER SYSTEM 0 O ENCLOSURE) AND BE USED FOR ALL SINGLE PHASE AND THREE PHASE AND I S TO INCLUDE COST I N BID. 08/13/10 PERMIT/BID SET MOTORS RATED ABOVE 1/2 HP THAT REQUIRE AUXILIARY CONTROL . 1 DENT I F I CAT I ON PRODUCTS TELEPHONE OUTLETS AND CONDUITS 0 0 PROVIDE CONTROL DEVICES (AUXILIARY CONTACTS, TRANSFORMERS, 2. ALL RECESSED INCANDESCENT FIXTURES SHALL BE PROVIDED WITH 4 H-O-A, ETC. ) IN STARTERS AS REQUIRED FOR INTERLOCKS. COORDINATE APPLICABLE THERMAL PROTECTION. DATA OUTLETS AND CONDUITS 0 O ALL CONTROL DEVICES WITH MECHANICAL CONTRACTOR. COMBINATION WITH PULLWIRE STARTER/DISCONNECT SWITCHES SHALL CONTAIN FUSIBLE SWITCHES 3. WHERE FLUORESCENT FIXTURES ARE SPECIFIED, THEY SHALL BE NOTE : AND ONLY USED WHERE INDICATED ON DRAWINGS. PROVIDED WITH HIGH POWER FACTOR RAPID START BALLASTS, UL TELEPHONE AND DATA CABLING O p LISTED, CBM CERTIFIED, AND ETL APPROVED WITH EFFICIENCY FACTORS 1 . ELECTRICAL CONTRACTOR I S TO FURNISH AND 2 . MANUFACTURER SHALL BE SQUARE D, GENERAL ELECTRIC OR CUTLER I N ACCORDANCE WITH "THE ENERGY POLICY ACT OF 1992" AND ITS INSTALL PULL WIRE WHEN INSTALLING TELEPHONE AND DATA CONDUIT 0 0 HAMMER. AMENDMENTS AS A MINI MUM. CONDUIT. TECHNOLOGY CONTRACTOR I S TO FA SYSTEM I S TO FURNISH AND INSTALL A SEPARATE PULL CEILING MTD. SMOKE DETECTORS 0 0 DONE BY LL'S J. GROUNDING 4. THIS CONTRACTOR SHALL FURNISH ADDITIONAL AUXILIARY SUPPORT WIRE FOR FUTURE USE WHEN INSTALLING BE BE DONER. AT STEEL HANGER WIRES ADEQUATELY S I ZED TO SUPPORT THE WEIGHT OF CABLING. DUCT MID. SMOKE DETECTOR O O ELEC. CONTR'S. 1 . FURNISH AND INSTALL COMPLETE WIRED GROUNDING CONDUCTOR THE FIXTURE FASTENED TO THE BUILDING STRUCTURE (MINIMUM TWO EXPENSE. SYSTEM, #12 AWG MINIMUM, SIZED AND INSTALLED I N ACCORDANCE PER FIXTURE) FOR ALL FIXTURES I N LAY-IN CEILINGS AND OTHER FIRE ALARM SYSTEM (SEE DETAILS) 0 0 INCLUDE ALL WITH THE LATEST ADOPTED EDITION OF THE NATIONAL ELECTRICAL FIXTURES AS REQUIRED BY THE LANDLORD AND LOCAL CODE OFFICIALS. COSTS IN BID. CODE , STATE AND LOCAL CODES, THE LANDLORD'S TENANT CRITERIA FIXTURES TO FIT TIGHT AGAINST CEILING CONSTRUCTION TO ELIMINATE AND AS NOTED IN THE SPECIFICATIONS AND AS INDICATED ON THE LIGHT LEAKAGE . MUSIC SYSTEM/SPEAKERS/CABINET O 0 DRAWINGS. 5. FURNISH AND INSTALL APPLICABLE FIRE RATED DRYWALL BOXES OVER MUSIC SYSTEM WIRING IN CONDUIT O OCR 2 . ALL CONDUIT, INCLUDING FLEXIBLE CONDUIT AND METAL BOXES, SHALL RECESSED FIXTURES IN FIRE RATED CEILINGS AS REQUIRED BY CODES. . BE GROUNDED WITH A GREEN GROUNDING CONDUCTOR. FIELD COORDINATE AS REQUIRED TO AVOID CONFLICTS. MUSIC SYSTEM VOLUME CONTROL O O 0 3. GROUNDING CONNECTIONS MADE TO THE WATER PIPING SYSTEM SHALL 6. THIS CONTRACTOR SHALL FURNISH AND INSTALL SPLAY WIRING (GUY TEMPERATURE CONTROL SYSTEM IN CONDUIT O O BE COORDINATED WITH THE PLUMBING CONTRACTOR AND A BONDING WIRING) AND SEISMIC BRACING FOR ALL FIXTURES AND EQUIPMENT AS JUMPERS INSTALLED AROUND WATER METER PER CODES AND AS REQUIRED BY STATE AND LOCAL CODES AS APPLICABLE . PLUGMOLD O INDICATED ON DRAWINGS. NMI 7. WALL-MOUNTED FIXTURES SHALL BE MOUNTED PLUMB WITH BUILDING RTU'S Project No. 44122/10038 4. ALL DEVICES SHALL BE BONDED TO THE CONDUIT SYSTEM, USE A LINES AND INSTALLED WITH PROPER BOX AND COVER HARDWARE . SERVICE LITE, SWITCH AND RECEPTACLE O O BONDING JUMPER BETWEEN THE OUTLET BOX AND THE DEVICE GROUNDING TERMINAL . METAL-TO-METAL CONTACT BETWEEN THE 8. SURFACE AND STEM MOUNTED FIXTURES TO BE HUNG FROM BOXES GENERAL NOTE Scale AS NOTED DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE AS A BOND FOR SECURELY FIXED TO THE STRUCTURE . USE CANOPY TO COVER THIS SCHEDULE IS INTENDED AS A "QUICK" REFERENCE. ALL ITEMS LISTED HERE ARE SPECIFIED AND DETAILED MO EITHER SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. ALL MOUNTING HARDWARE . ON THESE DRAWINGS. IF' THE CONTRACTOR ENCOUNTERS ITEMS THAT ARE CONTRADICTORY THEN IT IS HIS JUNCTION BOXES, OUTLET BOXES, AND PULL BOXES SHALL BE BONDED RESPONSIBILITY TO INFORM H & M'S CONSTRUCTION MANAGER SO THAT THESE ITEMS CAN BE CLARIFIED D r a•w B r: REK TO THE CONDUIT SYSTEM. FOR THE CONTRACTOR. 5. RUN A SEPARATE ISOLATED INSULATED GROUNDING CONDUCTOR, #12 RESPONSIBILITY SCHEDULE CODED NOTES AWG MINIMUM, I N EACH CONDUIT FEEDING THE CASH WRAP AND OTHER 0 ALL FINAL CONNECTIONS TO EQUIPMENT BY H & M. COMPUTERIZED EQUIPMENT AS SHOWN ON DRAWINGS. � � ate too uS2z0ES1• it 0 SEE POWER RISER FOR ADDITIONAL INFORMATION. `NM` a Droving No. ti ELECTRICAL SPECIFICATIONS I I ELECTRICAL SPECIFICATIONS `' NONE i E5 .1 EL CIRICAL SH CIFICATI • NS A. TELEPHONE/DATA SYSTEM - SECTION 16740 PROVIDE UNIT WITH THE FOLLOWING ACCESSORIES: 8. MAKE SPLICES, TAPS, AND TERMINATIONS ONLY AT INDICATED B. SOUND SYSTEM IBW SOLUTIONS) 711/11/ LEVITON: #5G108-RW5: WHITE CAT 5 SNAP-IN JACK OUTLETS, TERMINALS, AND CROSS-CONNECT AND PATCH PANELS. A. SUMMARY #4108W-1SP: SINGLE PORT WALL MOUNTED FACE 9. USE SPLICE AND TAP CONNECTORS COMPATIBLE WITH MEDIA A. SOUND EQUIPMENT SHALL BE FURNISHED AS FOLLOWS: 1 . SECTION INCLUDES: PLATE TYPES. 1 . SPEAKER CABLING AND DJ CABLING BY ELECTRICAL CONTRACTOR A. WIRE , CONDUIT, BOXES, CABLE , CONNECTING DEVICES, #41080-1WP: SINGLE PORT FACE PLATE 10. INSTALL A PULL WIRE IN EACH AND EVERY EMPTY CONDUIT. PER B W SOLUTIONS REQUIREMENTS. CONTACT BEN NOURY AT: INSTALLATION AND TESTING FOR WIRING SYSTEMS TO BE #41080-2WP: DOUBLE PORT FACE PLATE 11 . EACH CABLE SHALL BE TERMINATED AND LABELED WITH THE PORT B W SOLUTIONS USED AS SIGNAL PATHWAYS VOICE AND HIGH-SPEED DATA #41080-3WP: TRIPLE PORT FACE PLATE NUMBER AT PANEL A. 2722 LOKER AVE WEST ST. D TRANSMISSION. #41080-4WP: QUAD PORT FACE PLATE 12. T.C. SHALL INSTALL A CATEGORY 5 RATED 25-PAIR CABLE FROM CARLSBAD, CA 92010 B. MAKE PROVISIONS TO PROVIDE EXTENSION OF HIGH SPEED #41080-6WP: SIX PORT FACE PLATE THE MALL OR BUILDING PHONE ROOM AND/OR SUB PHONE ROOM (760) 431-2833 DATA CONNECTION. SMART JACK BY TELCO TO TENNANT #49252-PCM: COMBO FRONT/REAR MANAGER TO THE TELEPHONE BACKBOARD IN THE LAN ROOM, TERMINATED SPACE . PANEL TO A 66-BLOCK ON BOTH ENDS. FOR PRICING AND ORDER PLACEMENT. C. REVIEW RESPONSIBILITY SCHEDULE ON THIS SHEET . #P1040-10S: 120 VOLT VERTICAL POWER STRIP 2. RACK AND ASSOCIATED EQUIPMENT IN RACK, SPEAKERS, SPEAKER D. REVIEW DATA CABLE MATRIX & NOTES FOR DATA (PROVIDE TOTAL OF 1 ) N. GROUNDING BACKBOXES AND DJ JACK CABLING . CONDUIT FILL ON THIS SHEET. 1 . GROUND CABLE SHIELDS, DRAIN CONDUCTORS, AND EQUIPMENT TO US220 HUBBELL: #P5E48UEW: WHITE 48-PORT PATCH PANEL ELIMINATE SHOCK HAZARD AND TO MINIMIZE GROUND LOOPS, B. THIS CONTRACTOR SHALL INSTALL ALL SPEAKERS, REMOTE VOLUME CONTROLS, B. DEFINITIONS #P5E24UEW: WHITE 24-PORT PATCH PANEL COMMON-MODE RETURNS, NOISE PICK-UP, CROSS TALK, AND SPEAKER BACK BOXES, ASSOCIATED CABLING AND DJ JACK CABLING. WASHINGTON SQUARE 1 . EMI : ELECTROMAGNETIC INTERFERENCE . #P5E24UE : BLACK 24-PORT PATCH PANEL OTHER IMPAIRMENTS. 2. IDC: INSULATION DISPLACEMENT CONNECTOR. " 2. BOND SHIELDS AND DRAIN CONDUCTORS TO GROUND AT ONLY ONE C. SPEAKER LOCATIONS SHOWN ON THE DRAWING ARE FOR BIDDING 9585 S.W. Washington Square 3. LAN: LOCAL AREA NETWORK. PANDUIT: #WMPV45E : 83" VERTICAL WIRE MANAGER POINT IN EACH CIRCUIT. PURPOSES ONLY. THIS CONTRACTOR SHALL INSTALL AND WIRE SUITE H08 4 . PVC: POLYVINYL CHLORIDE . 3. SIGNAL GROUND TERMINAL : LOCATE IN EACH EQUIPMENT ROOM SPEAKERS PER B W SOLUTIONS PROVIDED INSTALLATION DRAWINGS. ALL 5. UTP: UNSHIELDED TWISTED PAIR. COOPER B-LINE : #SB1712FB: FLAT BLACK LADDER RACK AND WIRING CLOSET. ISOLATE FROM POWER SYSTEM AND CABLING SHALL BE RUN TO SOUND RACK LOCATION IN ELECTRIC ROOM. PORTLAND, OR 97223 #SB213312FB: RACK TO RUNWAY EQUIPMENT GROUNDING. LEAVE 6 FEET TAILS FOR FINAL CONNECTION TO SOUND EQUIPMENT BY A C. QUALITY ASSURANCE SUPPORT 4. SIGNAL GROUND BUS: MOUNT ON WALL OF MAIN EQUIPMENT ROOM B W SOLUTIONS TECHNICIAN. CLASS: RED 1 . TECHNOLOGY INSTALLER (T.C. ) QUALIFICATIONS: #S13211312FB: WALL ANGLE BRACKET WITH STAND-OFF INSULATORS. AN EXPERIENCED INSTALLER WHO IS A BISCI REGISTERED 5. SIGNAL GROUND BACKBONE CABLE: EXTEND FROM SIGNAL D. ALL SOUND CABLING SHALL BE IN CONDUIT. CONDUIT SHALL BE CONTINOUS TECHNICIAN LEVEL II INSTALLER. RACK SOLUTIONS: #2USHL-020-FULL-20V 19" RACK MOUNT SHELF GROUND BUS TO SIGNAL GROUND TERMINAL IN EACH WIRING FROM SPEAKER-TO-SPEAKER. HOMERUN FROM LAST SPEAKER TO SOUND RACK 2. COMPLY WITH NFPA 70, EIA/TIA 566. 3. FINISH: FLAT BLACK POWDER COAT. CLOSET AND EQUIPMENT ROOM. IN ELECTRIC ROOM SHALL BE IN CONDUIT. 3. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, ARTICLE 100, BY A TESTING I . TWISTED-PAIR CABLES, CONNECTORS, AND TERMINAL EQUIPMENT 0. INSTALLATION IN EQUIPMENT ROOMS AND CABINETS AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, 1 . LISTED AS .COMPLYING WITH CATEGORIES 5 OF EIA/TIA-568-B. DATA 1 . PROVIDE BACKBOARD AS SHOWN ON THE DRAWINGS. AND MARKED FOR INTENDED USE. AND TELEPHONE BRANCH CABLE SHALL BE CATEGORY 5e. 2. MOUNT PATCH PANELS, TERMINAL STRIPS, AND OTHER 2. CONDUCTORS: SOLID COPPER CONNECTING HARDWARE IN THE SPECIFIED CABINET. E. A CONDUIT RUN SHALL NOT HAVE MORE THAN THREE (3) BENDS IN A RUN D. COORDINATION 3. UTP CABLE : COMPLY WITH EIA/TIA-568-B. FOUR THERMOPLASTIC- 3. GROUP CONNECTING HARDWARE FOR CABLES INTO SEPARATE BETWEEN SPEAKERS OR BETWEEN SPEAKER AND SOUND RACK. WHEN A 1 . COORDINATE WORK OF THIS SECTION WITH OWNER'S TELEPHONE INSULATED, INDIVIDUALLY TWISTED PAIRS OF CONDUCTORS; NO. 24 LOGICAL FIELDS. RUN REQUIRES MORE THAN THREE (3) BENDS, A PULL BOX OF SUITABLE SWITCH, TELEPHONE INSTRUMENT, WORKSTATION, AND LAN AWG, COLOR-CODED; ENCLOSED IN PVC JACKET. 4. USE PATCH PANELS TO TERMINATE CABLES ENTERING THE SIZE SHALL BE PLACED IN SUITABLE LOCATION TO MEET THE ABOVE EQUIPMENT SUPPLIERS. 4. UTP CABLE CONNECTING HARDWARE: COMPLY WITH EIA/TIA-568-B. CABINET. CONDITIONS. � . t ) A. ADJUST ARRANGEMENTS AND LOCATIONS OF DISTRIBUTION IDC TYPE, USING MODULES DESIGNED FOR BUNCH DORM CAPS OR FRAMES, PATCH PANELS, AND CROSS CONNECTS IN TOOLS. P. IDENTIFICATION F . ALL FINAL TERMINATIONS AT THE SOUND RACK SHALL BE DONE BY EQUIPMENT ROOMS AND WIRING CLOSETS TO A. IDC TERMINAL BLOCK MODULES: INTEGRAL WITH 1 . IDENTIFY SYSTEM COMPONENTS COMPLYING WITH APPLICABLE H&M'S SOUND SYSTEM TECHNICIAN. ACCOMMODATE AND OPTIMIZE ARRANGEMENT AND SPACE CONNECTOR BODIES, INCLUDING PLUGS AND JACKS WHERE REQUIREMENTS IN DIVISION 16, ELECTRICAL IDENTIFICATION AND , -76 REQUIREMENTS OF TELEPHONE SWITCH AND LAN INDICATED. THE FOLLOWING SPECIFICATIONS. G. NO SUBSTITUTIONS OF B W SOLUTIONS EQUIPMENT IS PERMITTED. THE t EQUIPMENT. " B. IDC CONNECTING HARDWARE : CONSISTENT THROUGHOUT 2. SYSTEM: NUMBER THE PORTS CONSECUTIVELY (E.G. , 1 , 2, 3. . .ETC. ) . CONTRACTOR MUST PURCHASE EQUIPMENT DIRECTLY THROUGH B W SOLUTIONS `, •`- B. REFER TO H&M SUPPLIED US/CA STANDARD STORE IT PROJECT. 3. WORKSTATION: LABEL CABLE PORT NUMBER ON CABLE SHIELDING TO ENSURE COMPATIBILITY WITH THE SYSTEM HEAD, END PROVIDED BY H&M. j DEPARTMENT SPECIFICATIONS, " VERSION 8.0, UPDATED 26 5. PATCH PANELS: MODULAR PANELS HOUSING MULTIPLE, NUMBERED WITHIN THE OUTLET BOX. MARCH 2010 FOR ADDITIONAL INFORMATION FOR JACK UNITS WITH IDC-TYPE CONNECTORS AT EACH JACK FOR 4. DISTRIBUTION RACKS AND FRAMES: CONSECUTIVELY LABEL EACH COORDINATION. PERMANENT TERMINATION OF PAIR GROUPS OF INSTALLED CABLES. UNIT AND FIELD WITHIN THAT UNIT. �.p _•. C. TECHNOLOGY CONTRACTOR SHALL COORDINATE A. NUMBER OF PORTS PER FIELD: 5. WITHIN CONNECTOR FIELDS, IN WIRING CLOSETS AND EQUIPMENT INSTALLATION OF HIGH-SPEED DATA CONNECTION WITH 1 ) PATCH PANEL "A" SHOULD BE IN TWO PARTS (1 ) 48 ROOMS: LABEL EACH CONNECTOR AND EACH DISCRETE UNIT OF SERVICE PROVIDER TO ALLOW ALL EQUIPMENT TO BE PORT PANEL, HUBBELL #P5E48UEW, AND (1 ) 24 PORT CABLE-TERMINATING AND CONNECTING HARDWARE. INSTALLED IN TENANT SPACE . PANEL , HUBBELL #P5E24UEW, AND PATCH PANEL "B" 6. CABLES, GENERAL: LABEL EACH CABLE WITHIN 4 INCHES TO EACH D. TECHNOLOGY CONTRACTOR WILL MAKE ALL CROSS SHOULD BE A 24 PORT PANEL , HUBBELL #P5E24UE. IN TERMINATION AND TAP USING ALL THREE LISTED IDENTIFICATION CONNECTIONS NEEDED TO EXTEND THE DATA CONNECTION S T OR Ei H ST THE PRODUCTS, ACCESSIBLE CLOSET OR JUNCTION OR FROM THE BUILDING DEMARK TO TENANT DEMARK BEFORE STORE THAN REGISTERS, PANEL OUTLET BOX, ELSEWHERE DATA CONDUIT FILL REQUIREMENTS INSTALLATION OF HIGH-SPEED DATA SERVICE. SHOULD BE (2) 48 PORT PANELS. IF THE STORE HAS 24 7. EXPOSED CABLES AND CABLES IN CABLE TRAYS AND WIRE . OR MORE REGISTERS PATCH PANEL "A" SHOULD IN THREE TROUGHS: LABEL EACH CABLE AT INTERVALS NOT EXCEEDING 15 CONDUIT INSIDE CABLE OUTSIDE DIAMETER mm ( in. ) E. TELEPHONE/DATA CONDUIT SYSTEM PARTS 92) 48 PORT PANELS AND (1 ) 24 PORT PANEL PLUS FEET. CONDUIT DIAMETER 1 . ELECTRICAL CONTRACTOR TO PROVIDE TELEPHONE SERVICE ONE ADDITIONAL WIRE MANAGEMENT RACK. IN ALL CASES 8. CABLE SCHEDULE : POST IN PROMINENT LOCATION IN EACH WIRING TRADE - - - CONDUIT OR DUCT TO TELEPHONE BOARD AS SHOWN ON PLANS. PATCH PANEL "B" WILL BE A 24 PORT PANEL , HUBBELL CLOSET AND EQUIPMENT ROOM. LIST INCOMING AND OUTGOING SIZE mn in 3.3 4.6 5.6 6. 1 7.4 7.9 9.4 13.5 15.8 17.8 CONDUIT SHALL BE RIGID OR E .M.T. FLEX OR GREENFIELD IS #P5E24UE . CABLES AND THEIR DESIGNATIONS, ORIGINS, AND DESTINATIONS. (0. 13) (0. 18) (0.22) (0.24) (0.29) (0.31 ) (0.34) (0.53) (0.62) (0.70) H B K NOT PERMITTED. THERE SHALL BE EASY ACCESS TO ALL B. MOUNTING: CABINET PROJECT WITH RIGID FRAME AND CLEAR PLASTIC COVER. PROVIDE PULL BOX LOCATIONS IF THERE ARE MORE THAN 3 BENDS. E .C. 6. JACKS AND JACK ASSEMBLIES FOR DATA CIRCUIT UTP CABLE: ELECTRONIC COPY OF FINAL COMPREHENSIVE SCHEDULES FOR " MUST NOTIFY THE TC I N WRITING, THE EXACT LENGTH OF THE MODULAR, COLOR-CODED, RJ-45 RECEPTACLE UNITS WITH PROJECT, I N SOFTWARE AND FORMAT SELECTED BY OWNER. 1/2 16 0.622 1 1 •„ • • • • • • • • • •• • , , • • • • • _ • • •„ • • • CONSULTANTS, LTD CONDUIT, HOW MANY BENDS THERE ARE, PROVIDE THEM WITH A INTEGRAL I DC-TYPE TERMINALS. - ' ' ' ' ' ' '' ' '. . . . .. . . . . Mechanical & Electrical Design Services A. 1 PORT JACK LOCATION, (1 ) # / FIELD QUALITY CONTROL MAP OF THE BENDS. E .C. MUST VERIFY WITH MALL AND LOCAL ( ) LEVITON #5G108-RW5 W/LEVITON Q. 3/4" 21 0.824 6 5 4 3 2 2 1 TELCO PROVIDER WHICH TELEPHONE ROOM LOCATION TO RUN THE #41080-1WP FACE PLATE. 1 . THE H&M I .T. REPRESENTATIVE RETAINS THE RIGHT TO BE PRESENT B. 2 PORT JACK LOCATION, (2) LEVITON TON 5G108-RW5 W LEV I TON AT ANY OR ALL CABLE CERTIFICATION. THE CONTRACTOR SHALL .. ' . . ' ' ' ' ' ' .. ' ' ' ' ' ' ' ' ' 171 Charring Cross Drive S. CONDUIT FROM TO H&M'S SPACE . ELECTRICAL CONTRACTOR SHALL { ) # / VERIFY ALL CONDUIT RUNS ARE NO LONGER THAN 290'-0" . #41080-2WP FACE PLATE. PROVIDE WRITTEN NOTICE 48 HOURS PRIOR TO THE BEGINNING OF 1 " 27 1 .049 8 8 7 6 3 3 2 1 WesterB Westerville, Ohio 43081 2 . THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL C. 3 PORT JACK LOCATION, (3) LEVITON #5G108-RW5 W/LEVITON THE CERTIFICATION PROCESS. 614.882.1199 CONDUIT AND OUTLET BOXES FOR TECHNOLOGY CABLING. #41080-3WP FACE PLATE. 2. INSPECT THE CABLES FOR DAMAGE PRIOR TO PERFORMING FAX 614.882,1857 3. THE TECHNOLOGY CONTRACTOR SHALL PROVIDE AND INSTALL ALL D. 4 PORT JACK LOCATION, (4) LEVITON #5G108-RW5 W/LEVITON TESTING, IF CABLE IS DAMAGED REPULL CABLE. 1 1/4" 35 1 .380 16 14 12 10 6 4 • 3 1 1 1 25 PAIR AND CAT5E CABLE , DATA AND PHONE JACKS, FACE PLATES, #41080-4WP FACE PLATE. 3. THE CONTRACTOR SHALL PROVIDE A COPY OF CERTIFICATION TEST PATCH PANELS, TECHNOLOGY CABINET AND MISCELLANEOUS E . 6 PORT JACK LOCATION, (6) LEVITON #5G108-RW5 W/LEVITON REPORTS TO THE ENGINEER IN BOTH HARDCOPY AND ELECTRONIC EQUIPMENT TO MEET THE SPECIFICATIONS. #41080-6WP FACE PLATE. FORMAT . CONTRACTOR SHALL ALSO PROVIDE A COPY TO THE 1 1/2" 41 1 .610 20 18 16 15 7 6 4 2 1 1 4. E.C. SHALL PROVIDE PLYWOOD TERMINAL BOARD AS SHOWN ON F . WALL TELEPHONE LOCATION, (1 ) LEVITON #5G108-RW5 CABLE TESTER'S DATABASE MANAGEMENT SOFTWARE. Drowings and written material appearing herein constitute original DRAWINGS. W/LEV I TON #41080-1 SP WALL PLATE 4. INDEPENDENT SYSTEM CERTIFIED TESTING MAY BE REQUIRED, AT 2" 53 2.067 30 26 22 20 14 12 7 4 3 2 and unpublished rock of the Architect and may not he duplicoled, 5. A CONDUIT RUN SHALL HAVE NO MORE THAN THREE (3) BENDS I N A G. SURFACE BOX FOR DATA PORTS AT CASHWRAPS: (1 ) LEVITON THE DISCRETION OF THE H&M I .T. DEPARTMENT, PROVIDED AT THE u s e d o r d i s c l o s e d w i t h o u t w r i t t e n c o n s e n t of t h e A r c h i t e c t RUN BETWEEN OUTLET BOXES OR BETWEEN OUTLET BOX AND A #42777-1WA. EXPENSE OF THE CONTRACTOR, IN THE EVENT OF NON- 7. T.C. SHALL SUPPLY WIRE MANAGEMENT RACKS FOR THE DATA RACK AS PERFORMANCE OF THE SPECIFIED TESTING PROCEDURES c(�kIBH ARCHITECT - 2010 METAL CABINET OR PULL BOX. WHEN A RUN REQUIRES MORE 2 1/2" 63 2.469 45 40 36 30 17 14 12 6 3 3 THAN THREE (3) BENDS, A PULL BOX OF SUITABLE SIZE SHALL BE DESCRIBED IN THIS SPECIFICATION. REFER TO H&M SUPPLIED "US/CA SUBMITTALS AND/OR INSTALLATION PROCEDURES. PLACED IN A SUITABLE LOCATION TO MEET THE ABOVE STANDARD STORE IT DEPARTMENT SPECIFICATIONS, " VERSION 8.0 5. DATA CABLE TEST REPORTS - QAQC CONDITIONS. DAISY CHAINING OR BENDING BEHIND WALLS IS UPDATED 26 MARCH 2010 FOR ADDITIONAL INFORMATION. A. UPON COMPLETION OF THE CABLE INSTALLATION, THE 3" 78 3.068 70 60 50 40 20 20 17 7 6 6 ABSOLUTELY NOT PERMITTED. CONTRACTOR SHALL PERFORM COMPLETE COPPER CABLE No. Dole Issue 6. ALL TELEPHONE AND DATA CABLING SHALL BE IN CONDUIT. CERTIFICATION TESTS ON EVERY CABLE , INCLUDED BUT NOT . CONDUIT SHALL BE CONTINUOUS FROM DEVICE TO DATA RACK IN J . IDENTIFICATION PRODUCTS LIMITED TO: 3 1/2" 91 3.548 MAX MAX MAX MAX MAX MAX 22 12 7 6 05/28/10 100% SET LAN ROOM. CONDUIT SHALL MEET FILL REQUIREMENTS AS 1 . CABLE LABELS: SELF-ADHESIVE VINYL OR VINYL-CLOTH 1 ) FOR CATEGORY 5e CABLING AND HIGHER: 05/28/10 VT PACKAGE INDICATED IN THE TABLE ON THIS SHEET . WRAPAROUND TAPE MARKERS, MACHINE PRINTED WITH A) WIRE MAP 7. PULL-STRINGS MUST BE PLACED I N ALL CONDUIT BY E.C. AND T.C. ALPHANUMERIC CABLE DESIGNATIONS. B) LENGTH 4" 103 4.026 MAX MAX MAX MAX MAX MAX 30 14 12 7 07/02/10 100% COMPLETE SET MUST RUN NEW PULL-STRINGS THROUGH CONDUIT ALONG WITH 2. BROTHER P-TOUCH (OR EQUIVALENT) WITH BLACK ON WHITE C) ATTENUATION 07/28/10 LANDLORD SET CABLES FOR FUTURE EXPANSION CAPABILITIES. LABELING. D) NEAR END CROSS TALK (NEXT) 3. HANDWRITTEN LABELS ARE NOT PERMITTED. E) EQUAL LEVEL FAR END CROSS TALK (ELFEXT) .'•'.'•'•'•'•'•'•'•'.'.'•'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.' v ,4/ 4..� A, 44/ ,(k'.� v.1 .4..� ..� v 08/13/10 PERMIT/BID SET F) PROPAGAT ION DELAY AND DELAY SKEW .� Pc?;,' R� Q���° �` w Q�b�O ,Q<b�4 ,z-�b�O �Z� �Q7�0 MANUFACTURERS K. EXAMINATION G) RETURN LOSS '''•'''''''''''''''''''''''._ '•''' ''''''''' �' C' (' C) 4 `- Q' �' O (.' V �' V F. V v v v �, 1 . APPROVED MANUFACTURERS: 1 . EXAMINE PATHWAY ELEMENTS INTENDED FOR CABLE , CHECK B. TEST SHALL BE PERFORMED TO PUBLISHED STANDARDS, :;:;;:•;: :' cry' o �,�Q �� <" ��� �� �"A. /A. CABLE : RACEWAYS, CABLE TRAYS, AND OTHER ELEMENTS FOR INCLUDING, BUT NOT LIMITED TO, THE LATEST REVISIONS OF '.•.•.'.'.•.•.'.•.•.•.•,•.'.•.•.•.•'.• •• • ' OQ- OV OQ OQ..�0 OQ�C Vi UQ�0 OV =�1 ) BELDEN WIRE & CABLE COMPANY (317) 983-5200 COMPLIANCE W I TH SPACE ALLOCATIONS, I NSTALLAT I ON E I A/T I A 568, I SO/I EC 1 1802 AND OTHER APPLICABLE :::•;•;:•;•• :•;•;•:•;•:•::::.:: •: ' c., J J 4 J <v J 2) ESSEX GROUP, INC. ; TELECOMMUNICATIONS PRODUCTS TOLERANCES, HAZARDS TO CABLE INSTALLATION, AND OTHER STANDARDS AT THE TIME OF INSTALLATION. .,, , ,. -4:" Q�O■ A,(O r Q - '`- Q �° Q�,r cz - DIVISION (214) 461-4000. CONDITIONS AFFECTING INSTALLATION. PROCEED WITH C. ALL TESTS SHALL BE PERFORMED WITH A CERTIFIED TEST Q Q I .� Q•Q` Q Q Q Q `„• Q 3) GENERAL CABLE (908) 769-3200 INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE DEVICE . ... �; oR� o•� �' �� �,� h� O� 4� o� 4) MOHAWK/CDT (800) 422-9661 BEEN CORRECTED. D. TESTER SHALL BE FACTORY CALIBRATED EACH CALENDAR ••• ••••••••• •••' • ..Ow �.. v �.�, •%� eV h 40 P. B. TERMINAL AND CONNECTOR COMPONENTS AND PATCH YEAR BY THE FIELD TEST EQUIPMENT MANUFACTURER AS c Q. c Q'�' O Q� Qv Qy Qy Q� PANELS. L . APPLICATION OF MEDIA STIPULATED BY THE MANUALS PROVIDED WITH THE FIELD Q �Q� 4t �� v 4- Q∎ Q`' Q� Q� \, 1 ) MANUFACTURERS AS LISTED I N THESE 1 . HORIZONTAL CABLES FOR DATA SERVICE : USE UTP CABLE TEST UNIT. THE CALIBRATION CERTIFICATE SHALL BE ,`-� �• p -� -� -� Q ..............: SPECIFICATIONS. NO SUBSTITUTIONS COMPLYING WITH CATEGORY 5e OF EIA/TIA-568-B FOR RUNS PROVIDED, UPON REQUEST, TO THE H&M I .T. DEPARTMENT. �, . . �' A. A,` PERMITTED. BETWEEN WIRING CLOSETS AND WORKSTATION OUTLETS. E . AUTO TEST SETTINGS PROVIDED I N THE FIELD TESTER FOR •.•.•.•.•.•.•.•.•.•• ���p G. SYSTEM REQUIREMENTS TESTING THE INSTALLED CABLING SHALL BE SET TO THE 1 . GENERAL : COORDINATE THE FEATURES OF MATERIALS AND M. INSTALLATION DEFAULT PARAMETERS. ••••••• EQUIPMENT SO THEY FORM AN INTEGRATED SYSTEM. MATCH 1 . WIRING METHOD: INSTALL WIRING AS DESCRIBED HEREIN. F . TEST SETTINGS FROM OPTIONS PROVIDED IN THE FIELD . . . CONCEAL WIRING EXCEPT IN UNFINISHED SPACES. TESTERS SHALL BE COMPATIBLE WITH THE INSTALLED CABLE " " ' " " ' " ' COMPONENTS AND INTERCONNECTIONS FOR OPTIMUM FUTURE " " """"' " " " " PERFORMANCE . 2. INSTALL CABLE USING TECHNIQUES, PRACTICES, AND METHODS UNDER TEST. 2. EXPANSION CAPABILITY: UNLESS OTHERWISE INDICATED, PROVIDE THAT ARE CONSISTENT WITH CATEGORY 5e RATING OF 6. REMOVE ANY MALFUNCTIONING CABLE, REPLACE/REPULL WITH CHART BASED ON "BICSI TELECOMMUNICATION DISTRIBUTION METHODS MANUAL" , "GENERAL CABLE" CONDUCTOR PAIRS IN CABLES, POSITIONS IN PATCH PANELS, CROSS COMPONENTS AND THAT ENSURE CATEGORY 5e PERFORMANCE OF NEW CABLE AND RETEST AS SPECIFIED ABOVE . AND "SUPERIOR ESSEX" CABLE . CONNECTS, AND TERMINAL STRIPS, AND SPACE IN BACKBONE COMPLETED AND LINKED SIGNAL PATHS, END-TO-END. CABLE TRAYS AND WIREWAYS TO ACCOMMODATE 50 PERCENT 3. INSTALL CABLE WITHOUT DAMAGING CONDUCTORS, SHIELD, OR R. CLEANING FUTURE INCREASE IN ACTIVE STATION PAIRS. JACKET. 1 . AFTER COMPLETING SYSTEM INSTALLATION, INCLUDING OUTLET 4. DO NOT BEND CABLE IN HANDLING OR IN INSTALLING TO SMALLER FITTINGS AND DEVICES, INSPECT EXPOSED FINISH. REMOVE BURRS, H. MOUNTING ELEMENTS RADIUS THAN MINIMUMS RECOMMENDED BY MANUFACTURER. DIRT, AND CONSTRUCTION DEBRIS AND REPAIR DAMAGED FINISH, 1 . BACKBOARDS: 3/4-INCH INTERIOR-GRADE , FIRE-RESISTIVE-TREATED 5. PULL CABLES WITHOUT EXCEEDING CABLE MANUFACTURER'S INCLUDING CHIPS, SCRATCHES, AND ABRASIONS. Project No. 44122/10038 PLYWOOD. RECOMMENDED PULLING TENSIONS. 2. DISTRIBUTION RACKS: FLOOR-STANDING,TWO POST NETWORK A. PULL CABLES SIMULTANEOUSLY IF MORE THAN ONE IS BEING S. DEMONSTRATION EQUIPMENT RACK DESIGNED FOR TELECOMMUNICATIONS INSTALLED IN THE SAME RACEWAY. 1 . ENGAGE A FACTORY-AUTHORIZED SERVICE REPRESENTATIVE TO Scale AS NOTED TERMINAL SUPPORT AND COORDINATED WITH DIMENSIONS OF B. USE PULLING COMPOUND OR LUBRICANT IF NECESSARY. USE TRAIN OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE, UNITS TO BE SUPPORTED. COMPOUNDS THAT WILL NOT DAMAGE CONDUCTOR OR AND MAINTAIN SYSTEMS. A. UL LISTED TWO POST NETWORK EQUIPMENT RACK WITH 3" INSULATION. A. TRAIN OWNER'S MAINTENANCE PERSONNEL ON PROCDURES UPRIGHTS AND 19" RACK WIDTH. COOPER B-LINE CATALOG C. USE PULLING MEANS, INCLUDING FISH TAPE , CABLE, ROPE, AND SCHEDULES FOR STARTING AND STOPPING, TROUBLE- OrovnBi: REK #SB556K084XUFB WITH GROUNDING ACCESSORIES, AND BASKET-WEAVE WIRE/CABLE GRIPS, THAT WILL NOT SHOOTING, SERVICING, AND MAINTAINING EQUIPMENT AND SEE SHEET "E5.1" F O R GROUNDING KIT AND ANCHOR. NO SUBSTITUTIONS DAMAGE MEDIA OR RACEWAY. SCHEDULES. 6. WIRING WITHIN WIRING CLOSETS AND ENCLOSURES: PROVIDE 2. TRAIN DESIGNATED PERSONNEL IN CABLE-PLANT MANAGEMENT PERMITTED. TECHNOLOGY R E S P O N SIBILIT Y z ADEQUATE LENGTH OF CONDUCTORS. TRAIN CONDUCTORS TO OPERATIONS, INCLUDING CHANGING SIGNAL PATHWAYS FOR I' TERMINAL POINTS WITH NO EXCESS. USE LACING BARS TO DIFFERENT WORKSTATIONS, REROUTING SIGNALS I N FAILED SCHEDULE. ,x.\2010 Jobs\10038\US220(52.ch.g • RESTRAIN CABLES, TO PREVENT STRAINING CONNECTIONS, AND TO CABLES, AND EXTENDING WIRING TO ESTABLISH NEW ' PREVENT BENDING CABLES TO SMALLER RADIUS THAN MINIMUMS WORKSTATION OUTLETS. 0 RECOMMENDED BY MANUFACTURER. Droving No. R 7. SEPARATION OF WIRES: COMPLY WITH EIA/TIA-569 RULES FOR ELECTRICAL t SEPARATING UNSHIELDED COPPER COMMUNICATION AND DATA- PROCESSING EQUIPMENT CABLES FROM POTENTIAL EMI SOURCES, SPECIFICATIONS INCLUDING ELECTRICAL POWER LINES AND EQUIPMENT. 1 NONE 1 1.g ELECTRICAL SPECIFICATIONS E5 . 2 (0 • 4111) • DD BB • AA • 0 • 0 I I I � " T NANT� I I I G�36 x12* RETURN DOMIN 79raUSM220' FROM MEZZANINE LEVEL. 40"x12" SUPPLY DOWN 19 36"x12" SUPPLY GOWN FROM MEZZANINE LEVEL. WASHINGTON SQUARE I I I O I I 1 I I FROM MEZZANINE LEVEL. 4:1)S 40«x12" RETURN DOWN FROM MEZZANINE LEVEL. 'w' Washington Square ®SENSOR TE I ■■ _ • ........_________I -�^ 1 ��•� t Wig_ M.�-- X1111 _ I wJ - ��I• .e '` � _—� DISPLAY, I ; n I I I :, (;c;; I ®(T ') : „ Iall L- TYP n�ivr ..r'�`80 I , II • 22x16 1 28 x16 I I CS iii : . \ — 21 �••••��'R (� I w TYP ��i t :: I:r '�J / 6«cr .� l —1._ ~a ( SALES a T Y I II 1 q 5 �� 1 ; ,� ' Ella I � (TYP) : ; c_ir ; . SD 1 2 • �:� I 1 �( 1 SD 1 .,•, ■.�� 470 14« 6« 70 •::.__1•1J1 4 ' ___ SD CI x1 480 w E 1 i DS I MACHINE 1 SALE j, r, 2 2x16 12"x1 24"x16" " < i SD—�- SD-1 2" I \ / I �' w I I I 12 430 430 -1 (TYP) 9'(1-?a'o s ; . ;,-1,, ›....0 . \ / , '\, :OR E SON oE) --••"--- 1 pr III G 1 ! 12"ø 465 „,,,''f„,:,,,.. : ' / \} \ 12"0 , I ',- - \ / 1 r MALL COMMON '` ., R 1 . i I 1 - = /I\ • i1 O N c�.I I I AREA - C.ii v \ • , x 1 460 ' J.-----lig51910. i 0 i _--= -- - / , 8 : ; �° 65 I , „ ” .s \ . ,_ przmi 4 11 22 x 6 6x12 I •jliiii = =- _--- -. - -- - _. 1111111111111111111 MN 11111•11111■11 IF us— _:I _E.__— — i CD ll `� — �:.—a `'.�i ■ - 71-__ \ . WOMENS / I I ,� S 1 12 0 I 1 sD 1 C \ I I :. A \ sam-a\s...,0 • ,, 3 � � 4, © 470 A-EA 47 --- SD-1 „ 1 1111 a 111111 00 I '' _ I I 8« IjIl S D-1 -1 „ , (TYP) 4; II 11 4 21 i 4 /1 30 I cl'" 2" ” 340 ” �� Q , �(TYP) H B K 0 T—STAY Emma I Ii I �► t 2 0 12.0) r 11 E CONSULTANTS, LTD„ I \®CMS — y i, (TYP) I _ I I A 2"x16” A . ii•1 1! ;, Mechanical & Electrical Design Services I 12"x 12" . • `:`' I , 111111111 18 x16. . 0 8". CI mum , II 11111111111111INTEIEME• � � I I �► 12"0 12"0 ��1 I , �� ��„� (TYP) ♦ , - I1 E WOMENS I I '� I I r`' ”'z %IV / 110 {Tom) 171 Charring Cross Drive S. : ; IL :�., �1,I ( 5 12 TYP I— c Suite 1B ,E �: a 'I 1,1. g 1 - r O( ) / I Westerville, Ohio 43081 ------ SD-1 i� " " 111, SD-1 I ®10 0 1 10 i SD 1 1 I ay....._.,__�.._�....___.._a T�.___..__,..,i " 614.882.1199 m 200 : ; , _1 ' _. __. _.. _. _.-._..._..__. _ _ 1 8 FAX 614,882, 857 mu 460 460 _ 5 ii I 1 c i,330 Lil _ __ __ _ ",I 11►a 330 a - . iwa_ I,f i:: ..--- 10 1 . p-,0 .� E 1 k _ _._ -: -_ _t. _ ,0 II '�._.__ DISPLAY 6 TYP WINDOW 2,„: :, ipxTyp) , , 1, 1'hill I U r .� 4 x1 ; 2 6 6 !: 1 I r ,: �, ,. ,1, r, - _ ill :;- Drori and written material on herein constitute original 1 — ._�.. �.�11 )��--.�— _1 'in= — — _ • - - — and unpublished cork of the Architect and may not be duplicated, .< — _._.__�,..— 3 B _ ' -- _— '-- — — _ _ rl:� _ _ _ �. - 1 - -11�, _ _ - — — used or disclosed without rrritlen consent of the Architect I _ I I ei 36"x12" RETURN DOWN. 1 — 1 I cOMBH ARCHITECT - 2010 I ►T — 'RtDll MEZZAhI I NE LEVEL. 0SENSOR UP TO MEZZANINE LEVEL SENSOR (TYP OF ALL SD 1) 0 36»x12" SUPPLY DOWN 0A0C FROM MEZZANINE LEVEL.' No. Dole Issue 05/28/10 100% SET ADJACENT 05/28/10 VT PACKAGE TENANT-WC. 07/02/10 100% COMPLETE SET STRUCTURAL ELEVATIONS 07/28/10 LANDLORD SET 08/13/10 PERMIT/BID SET BASED ON: X FIELD SURVEY ____ LANDLORD INFORMATION STRUCTURAL DRAWINGS ____ HEIGHTS UNAVAILABLE STORE IS LOCATED ON LEVEL 1 OF 2 FINISHED FLOOR TO BOTTOM OF DECK ABOVE IS APPROX. 14'-0" FINISHED FLOOR TO BOTTOM OF LOWEST STRUCTURAL MEMBER (STEEL OR CONCRETE BEAMS/ JOISTS) IS APPROX. 12'-3" ALL OTHER EQUIPMENT, PIPING, AND DUCTWORK ELEVATIONS ARE AS NOTED ON THE DRAWINGS. NOTE: CONTRACTOR IS TO VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BIDDING WORK. ANY CONDITIONS THAT AFFECT THE INSTALLATION OF THIS PROJECT MUST IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER OR BE INCORPORATED IN THE BID. DUCTWORK SHALL NOT BE FABRICATED OR ANY EQUIPMENT ORDERED PRIOR TO APPROVAL BY THE TENANT'S CONSTRUCTION MANAGER, me FIELD SURVEY BY CD ON 2-03-10 . Prefect No. 44122/10038 • Scele AS NOTED SEE SHEET M2.1d FOR 111!!!!!!!' WDB/KH MECHANICAL GENERAL NOTES N AND MECHANICAL CODED it NOTES. J:A2010.IotA10p3i'hUS2301rt2ta.dp tri M. 11111111 o Droving No. MECHANICAL PLAN VERIFY ALL CONDITIONS I ! . FIELD PRIOR TO BIDS. FIRST LEVEL I __a - 1/8"=1' ' 2 MECHANICAL PLAN FIRST LEVEL _ i NA 2 .1 a 0 79rit,m - - - - - - - r SEE SHEET M2.1c FOR ENLARGED - FLOOR PLAN 1 , OF THIS AREA. • :_ 220 . . ., . DD • BB AA 0 0 WASHINGTON SQUARE _ __ __ , , _ ,, on aw. Wathington &owe 1 , PORILANa OR - CUM RED cil IA- , HH. 1 I - 'f I I 19 36"X12" DOWN T O TENANT-N.I.C. I 40"X12" DOWN TO I I • FC ... 0 FIRST LEVEL L �— — /� FIRST LEVEL - ©ENS • 1 :: 390 SENSOR w ORTU 5 �.� SENSOR ia1 I MD _ J EF -�" . GC ' h._ .... -im"Aim—aria-iiiiiviiii Li-i-iiimi iiiii -ii aria I mum: T_ 2x18 �� I 11 _ 111117 32 x1 —.....——— ..__... empmeme MN own ma iris=owl w 0, ,. ' 4 RTU /la RTU SD-1 SD-1 TYP SD—' F ,. .1 1 - . . - .Ark I - ` �� k ,__� 380 3$0 400 �I �' w IN , I © — . .�51111 Id�1- 1!0- 1 SD �=. tt� 2" , 8 lr.. L ,, „s. ,,, , ,, ,, . ::: lir r ral ® ..t4 f•t s• " .. I ... I- '` ffi _ ...... P T -, r : 1 �, t jd / \\,,..,,,,. •,•`�a`y t, , t �,•.......4% (.,, . _f I 1111 ilea I I i I ,'a LJ �- 1 �, 1 ►1�, FC � J J ``\ JJ� $"x8" " �i 1 32"x1$" _ I MENS SALES® ® ELEVAT/ 2 Fc ,. ■ ,, � sa � ;Irk t /■ Inummiunniai ' I Y�i r' 150 F .a �- 12 _.- � ====CEM :�_ :=. .. In ...� 325 325 4 D(TYP) 4 1 1 1° 4 Tv) KI ABY M 2.3 14"x14" ° 1 v/ RTU ' ® SALES _ SD 1 MENS 4 � ' SALE AREA r_ AREA I �, ,'- 470 I I'% k SALE?® .� I ;,:�, 10"'' f 10''s I 470 ■■ " 1 / 8 SD-1 C 12 4, 0 , 3 SD-1 ■u I 12 ACC o o " 480 " _ / INSTALL UNIT ON ROOF alma � A 8"x14" �T 14 x14 16 x14 480 12 – � /:v; W CLEAR OF LANDLORD .x, Q i ;ii- ti,r �,` - « " ' II '''''A / .,:r EQUIPMENT. r :.. 6 x18 RTU H B ::::::::::**:::::::::::: -'0 10 5 22"x14" _ 1 110 , I ij Sa-1 N SD_1 Sp_1 . :.. I ' I MALL COMMO T`i 250 - _I 325 I o�.: �,. �„ 325 6 "a q ei 1;tai K 3 1 12m / x8 ,..— CON�T� L'ID !� < " x 2 '- IV 24 x 14 $�. _ ilea.... =- �� YP 0 ALL $ ) ec an c� do E act cal 0 Ser�nc A (TYP) �� - �I D-1 i ‘;125,,.$ r� 02j � {`( F M h i I ri esi n es Mr11M, 480 J� 470 �� ; p' ',►►�RZ�!►Z1 ►`�►��1►Z�1►r�I► �� « " ► i J ' , 171 Charring Cross Drive S. — — R 32 $ _ >.��►�' r�lln�, 1� ► Suite 1 B., ..l ___ — - - -- - - - - -- 3081 .. -- � �� 10 � � 32 —� �' ci x 1 2 ���!1f�,�i _ waste le ohio 4.__�__, __,_. . - - 1 3 w 2►�►��►.►mot► ►_►�1►�'� ►Z�1►�4►�'�►'�► '► �'"� ;4; "x $" $F :r', SD— 614.882.1199 � « a .... \„_ilea . :.. ;;,,< » " _ tv 47 FAX 614,882,1857 `� RTU �""© � -1 24 x14 /< ( 116"x1 2" 480© « 1 6 A 8"x 16" ' o `' PTZ k / OPEN TO ,il I11 32 x $ �k. y �._. KI 12 f TYP) ,. 6- a v� ,._; uJ / FLOW`� Sp-1 O SD-1 C� 1 x14 10t '2"0 �, I KIDS/BABY 350 A ( 325 I I �: .,,..:_.. I I ( r �ngs oppe r ng 1n igi 350 / a aw' and written moleriol o i here canstilule or nal SALES AREA ____ 2 1 / and unpublished work of the Architect and may not be duplicated« " r:— SD-1 , ' ^ ' -: z'� Sa-�1 used or disclosed without written consent of the Architect , , , 10 0 MW gm 10"0 18 x14"" . % 425 _1 �' I M _ 1 � 12" � 00 , N - 10 x14 �'1'�iiIj'I 4 �✓ M 425 E , g y« hd i rya 380 � 10 � ,r AR: ' ►I M ! IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIMIIIII 1•1k ►� ril ®{TYP); �. / 1 0A0C I q, 1 cro , ,,I, ,:.:, I ow. ,,E ,,-:, rif wig ;. 3 X111 I , No Dole Issue I`� SD-' q15, sp-'' Y �. � 32"x18" ��� ======o 50 1lii! NI �:,....:� � >._�■0 , �1 =— __ �_ __ __0 5 ? {s DUCT DOWN TO FIRST LEVEL " a r Fa t :v s s, k µ�.,r ii D SPLAY WI 05/28/10 VT PACKAGE �`/ j36"Xi2" DOWN TO 2 1 '111- I PAY DONVS. 07/02/10 100 COMPLETE SET � r , _ @(TYP) STAIRS I, 11 I I F 1 RST LEVEL I.� 1111111g I I I 07/28j10 LANDLORD SET,i .4,M__ , __.- ___, _ a _ �: m: �_, __, ____: L.. �'; '� ► J�� _ __ 08/13/10 PERMIT/81D SET - • - - - - - --— - __ — „_. - - �. ..._ - -, 32"x18" a RTU SENSOR 40 1 ADJACENT TENANT N.a T� �T R A L ELEVATIONS S U U 1 BASED ON: __x_.. FIELD SURVEY LANDLORD INFORMATION STRUCTURAL DRAWINGS „,_, HEIGHTS UNAVAILABLE STORE IS LOCATED ON LEVEL 2 OF 2 FINISHED FLOOR TO BOTTOM OF DECK ABOVE IS APPROX. 13'-8” FINISHED FLOOR TO BOTTOM OF LOWEST STRUCTURAL MEMBER (STEEL OR CONCRETE BEAMS/ JOISTS) IS APPROX. 11'-8" . ALL OTHER EQUIPMENT, PIPING, AND DUCTWORK ELEVATIONS ARE AS NOTED ON THE DRAWINGS. NOTE: CONTRACTOR IS TO VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BIDDING WORK. ANY CONDITIONS THAT AFFECT THE . INSTALLATION OF THIS PROJECT MUST IMMEDIATELY BE BROUGHT TO P r o j e c t No. 44122/10038 , THE ATTENTION OF THE CONSTRUCTION MANAGER OR BE INCORPORATED IN THE BID. DUCTWORK SHALL NOT BE FABRICATED OR ANY EQUIPMENT ORDERED PRIOR TO APPROVAL BY THE TENANT'S CONSTRUCTION MANAGER. c o I e AS NOTED FIELD SURVEY BY CD ON 2-03-10 immoi:DS WDB/KH SEE SHEET M2.1d FOR N MECHANICAL GENERAL NOTES O "' AND MECHANICAL CODED Droving d DNo. NOTES. MECHANICAL PLAN cf VERIFY ALL CONDITIONS I MEZZANINE LEVEL FIELD PRIOR TO BIDS . 1/8"=1'-0" 1 MECHANICAL PLAN - MEZZANINE LEVEL 1 i _ M 2 .1 b S7 1 s V C y O V .„, 4 - d 8 I 1 ,...--.-,,k • CS NIA � CV C � ow I cNiz I ,,,,,,,„IN 0 .., 5 @ ,_„,____,.: ,• , .. r•■\°"""'""''''''''N: 1. cn Lai el CNI "`4 C.,.. ; a to m _ Cf d (p Q p IOi ~ - N O 5 M c Z Co'\,--..„--Ni, le < , 0 nt in, + ;4 • f �"� o ago — -� a h o 5 Q 5 a _ V C\,1 millwiliall-1414'■7 w 9 og _ 426 .0_,,,,„, ...lig. 1 1 1 , , .. . „ ..,,.,,, .., s tiJ V L .' ° °' cwt — '- '- Q 01 ot) a, otnN Y W V 0 CO ' 1 !I moo I ; i — o o © o o CO CO N 00 M ° ac N N o N .- _ .. ! _ it ; c 111 tf) t` ^ OO m °` o Q O O O o w — c C1:1 V 'Q< d 4 a�� O ae a. ! h © ? CS T Ei) a C111) W re ID 0 Z Gm R!1 nom. W r a z O� a O<�GO W U, Wj Q W_14,030 Z0p 0 cif) 0 a s a . to 1- W 1- < 'r- .1.1 J .2 2 °Z.- WtnQ� Z Q Z z 0 FEND vZ a a J > ' i 0 a. 01 8.8 • '' o N p0 W o~�~W = —J 0 0 U Q J W O u Za=tea Zp co OC W -' = m muI c� 01-00 o E.5 . as N a (n 0... o v'`�0z m z —I U g t-,-,v) G '-4WWW Z r W Q o � z }z CO m < (� ( i (.� (� 0 N < )-OJ�2 W O O♦ O �I-�Om ~ m J Z 2 20 Z Zawt4i. _ E"' < Q LIU Z J 0 o!¢ a oOwQwm I.."' W W CJ I 1-- , CI 0 m 03 Li! Z - Z - M0 J CC I >• ° o o o W M •vi Q Z > co <i 2 6 Ch am z I— w cc ir U 0 0o v� a ��ia W0Ci1- cn ? o 0 oca W a i- o=w a 0 w W Z 0 J L � w W f co 2 < Z z o g o OcZ�za o W v_ O mo = �o � Cn W a `` in a t=n XW °X ••,... j� a L Z La CA I p W J F- (1)W 0 o_ < 0 U) L. Iwi.•vi 4 O O — _ tr CI 00 y. z 0 0 somi wool 0 a >.- _T 7 _ V U I CC .....J0,!.,(Pr.!) • WI NMI t ii j M !i • . . .. 'i '' 11 • • '•. • - •7""""....... .: . pz, / -. ., , :, , . ,, .. . , , . . ,. . ,,,,. " I Li..... i ' . , iin . ,i -, .,.' . 1 . . d • V O i i:p O. kill• Y �x p t . O �-•O t� •ty .... 000mme' If...... O ..__...... P • cn .. -- joie ._ 0 0 NIMIN MIN= MAIM rir"..ZI .°1 . kw 1 >< . , 0 _ •__ _..c- D .........,-- ........,„ ..... LA . ... ,__ . •.., r secip i r . ...... ..... N IP < , CI .... ..... 4 0 I , o e- .. irilr ', 1 LL W '.- i p s , •. •• . . , AO . • ��' W I --- -�} o.1TMVWie 1V�•eY�I�Rr .r T for --.-.1! _ W Y twos YW Y was YWW I _ T -am ow mg MP _ -.w- -T1w�.ww+woww/wwyw.."F ' ", -- • " fiW'M.114•!'�f.M:WJ�M:Mt14:M14'IA�: °, �r. L t - +�MOMDT.f 1 ----,...--MIND w:- :i. �7_ air j tp 0 I ,..4 No I ill ................... .................... .................... ..................... ... .. . ,. .. . tO • 11 1 ste Q..= —9••••. I- • . ., I 4--1 . . r:Z:::.-..-.--.--::::::::::::::::::-.7:-.1 .; . :, 1.- 1 1 0, . , -,, • , • . . . e e . . . rf) . - • •:- : M g) ....... _A 1 e ist,.. .44 '-=',- k ............•...•...j o- icy w 'O _ I: „. ,, _. . .. , - .,„,„ • s_ • - ilia .. 1 { 12; 41 ii..... In .........___...‘„ 1 11\ 8 i '•il ::::::::1 9 AI ,-, o 8 CI ) 1)1Z. , • se 1.I .■ ■ 1.4 Oil !ICAO N...........) -..I 8 ...,-!, ;(--) ,,, ,..., ...y:.O . .. .. ........ . N : - : 4 ..... .... 1 cv Ism 7; - ..... a. !6:../1 I ) i • , L-„ ,410) .. . . . . .. . . . . • . .• 4 �� �o Z 1 co ® m•-41/� ,,a MI -' 01. ' il �i. Z • . . • WA 0 I 0 M M• 1 0 Ia.. ... ..... ._. __ . . .. .__._.__......_.., . . .. ... _.._. . . . W ! co • O r VI- t!I M 8 I 1101 . <z _:........ :,• -.-.1,". .• ,. .,, , . , :, , • , N I,,,:--,, -,:-. :„ E:i 1 i; [..„......., i . . l - JJ 1 1 r ., 1 JJ a f.-....c4-.x.,:_ A 0 . , r _....,' .. _ ___ ___ ___ ___ ___ _ _._ ___ ___ .- .---r- am ,- ....... ....... (ID • r — ••'X -r 7///V# 1•.Y•IS:•::-j ......._ O tz t �3 az w N = t• 0 O g Z Y Z D N z 0 z I 0 U.I. M --I Q 1.— CC a_ L9 kl wd9Ls 010Z II Isithei AcaPsintil.MI#cId • SPRINKLER SYSTEM RESPONSIBILITY SCHEDULE LEGEND AND SYMBOLS MECHANICAL GENERAL NOTES iiim ,1. MECHANICAL CONTRACTOR SHALL VISIT JOB SITE AND BE FAMILIAR WITH LANDLORD'S REQUIREMENTS. NO ALLOWANCE WILL BE I FURNISHED BY INSTALLED BY WIRED BY 171 SUPPLY DIFFUSER AIL MADE FOR EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOB SITE AND/OR FAILURE TO PREDETERMINE ALL CONDITIONS ITEM N/A REMARKS MECH. ELEC. RE—USE 4 WAY THROW # EQUIPMENT DESIGNATION IMPOSED BY THE LANDLORD OR OTHER AUTHORITIES. - TENANT LANDLORD CONTR. LANDLORD CONTR. EXISTING CONTR. CONTR. 7' SUPPLY DIFFUSER 2. ALL ROOF CUTTING, PATCHING AND FLASHING REQUIRED TO INSTALL THE MECHANICAL SYSTEMS SHALL BE BY A LANDLORD 1 3 WAY THROW Va. FIRE DAMPER — FD APPROVED ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. COORDINATE ROOF PENETRATIONS WITH LANDLORD AND SPRINKLER PIPING • • GENERAL CONTRACTOR. t;' SUPPLY DIFFUSER 2 WAY THROW =Um © MOTOR OPERATED 3. MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL STRUCTURAL STEEL REQUIRED TO SUPPORT ANY SPRINKLER HEADS • • w1• DAMPER — MOD MECHANICAL EQUIPMENT. THIS CONTRACTOR SHALL COORDINATE LOCATIONS AND REQUIREMENTS WITH THE GENERAL CONTRACTOR Ea RETURN GRILLE AND LANDLORD PRIOR TO BID. FIRE EXTINGUISHERS • • -- © ZONE DAMPER — ZD 4. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL TRADES, LANDLORD REQUIREMENTS, CEILING 13 HEIGHTS AND EXISTING STRUCTURAL CONDITIONS PRIOR TO FABRICATION OF ANY DUCTWORK OR ORDERING OF ANY EQUIPMENT. ACCESS DOOR/PANEL THE CONTRACTOR SHALL PROVIDE ALL NECESSARY OFFSETS AND FITTINGS WHICH MAY BE REQUIRED DUE TO SPACE CONSTRAINTS AS—BUILT DRAWINGS • '�O AUTOMATIC BACKDRAFT DAMPER — ABD OR OTHER CONDITIONS. — '1 BALANCE DAMPER 4•111111.•• TR MATERIAL, DAMPERS MUST COMPLY AN 5. ALL DUCTWORK, DUCT MAEIAL, VOLUME DAMES MUS COMLD BE INSTALLED WITH THE LATEST EDITION SMACNA. ■ FLEXIBLE DUCT US220 cw S SPIN IN FITTING 6. DUCT DIMENSIONS SHOWN ARE INSIDE NET DIMENSIONS, ADD TO SHEET METAL SIZE FOR INSULATION. IN GENERAL, HOLD DUCT ROUND DUCT — UP TIGHT TO UNDERSIDE OF STRUCTURE UNLESS OTHERWISE NOTED OR REQUIRED BY FIELD CONDITIONS, WASHINGTON SQUARE GENERAL NOTE ; t ECCENTRIC DUCT TRANSITION 7. CONICAL BELLMOUTH FITTINGS WITH MANUAL BALANCING DAMPER TO BE USED FOR ALL ROUND BRANCH TAPS. THIS SCHEDULE IS INTENDED AS A "QUICK" REFERENCE. ALL ITEMS LISTED HERE ARE SPECIFIED AND DETAILED C-" ROUND DUCT — DOWN 9585 W. Washington Soars ON THESE DRAWINGS. IF THE CONTRACTOR ENCOUNTERS ITEMS THAT ARE CONTRADICTORY THEN IT IS HIS 8. FLEX CONNECTIONS TO DIFFUSERS ARE INSULATED FLEX WITH A MAXIMUM LENGTH OF 5 FT. fgJITE RESPONSIBILITY TO INFORM TENANT'S CONSTRUCTION MANAGER SO THAT THESE ITEMS CAN BE CLARIFIED • •14 CONCENTRIC DUCT TRANSITION FOR THE CONTRACTOR. Q TEMPERATURE SENSOR 9. THE MECHANICAL CONTRACTOR SHALL COORDINATE THE LOCATION OF CEILING GRILLES, REGISTERS AND DIFFUSERS WITH THE PORT1AND, OR 1r czim SUPPLY DUCT — UP 0 THERMOSTAT ARCHITECTURAL REFLECTED CEILING PLANS. CLAM RED ' O 10. DUCTWORK AND PIPING SHALL NOT BE LOCATED OVER THE TOP OF ANY ELECTRICAL PANELS OR EQUIPMENT. HVAC R E S P O N S I B I L I T Y SCHEDULE _ _ 5 DUCT MTD. SMOKE DETECTOR 11. MECHANICAL CONTRACTOR SHALL COORDINATE FLOOR, WALL AND ROOF PENETRATIONS, LOUVER SIZES, ETC. WITH GENERAL 1>c_ SUPPLY DUCT — DOWN TRADES. MECHANICAL CONTRACTOR IS TO PROVIDE AND INSTALL FIRE—RATED PIPE SLEEVES AND SEALS ON ALL EXISTING OR NEW (R) (a--4—■ UNDERCUT DOOR PIPING THAT PENETRATES A FIRE—RATED PARTITION. FURNISHED BY INSTALLED BY WIRED BY RE—USE ITEM MECH. ELEC. N/A REMARKS /! r; RETURN OR EXH. DUCT — UP POINT OF CONNECTION 12. THE CONTRACTOR SHALL COORDINATE AND PROVIDE ACCESS DOORS IN HARD CEILINGS FOR ALL EQUIPMENT WHICH REQUIRES TENANT LANDLORD CONTR. •LANDLORD CONTR. CONTR. CONTR. EXISTING ACCESS, SUCH AS: FIRE AND SMOKE DAMPERS, SMOKE DETECTORS, BALANCING DAMPERS, ETC. CO ROOF TOP UNITS • • CD RELOCATED 13. MECHANICAL CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT, PIPING AND DUCTWORK, NOT BEING USED OR SHOWN TO REMAIN,0 MS ........ .., RETURN OR EXH. DUCT — DOWN IS FULLY REMOVED AND NOT ABANDONED. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION, ROOF TOP UNIT FIELD INSTALLED (E) — EXISTING TO REMAIN 14, MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL IDENTIFICATION ON ALL ROOFTOP EQUIPMENT, PROVIDE PLASTIC ACCESSORIES LAMINATED PLATE OR STENCIL WITH A MINIMUM OF 4" HIGH BLACK LETTERS, INDICATING TENANTS NAME AND SPACE NUMBER.I ffli (D) EXISTING REMOVED VERIFY ACTUAL REQUIREMENTS WITH LANDLORD. ROOFCURB AND/OR CURB ADAPTER ELBOW W/TURNING VANES �/! FOR RTU AS REQUIRED 15. ALL 24 VOLT COMMUNICATION AND/OR SENSOR WIRING ASSOCIATED WITH THE HVAC CONTROL SYSTEM SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. ALL WIRING AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE .,-'. .,-\ STRUCTURAL SUPPORTS FOR RTU LATEST EDITION OF THE NATIONAL ELECTRIC CODES, LOCAL CODE AND LANDLORD REQUIREMENTS, THE MECHANICAL CONTRACTOR #_,, 4 ay $), \ - ,‘ AS REQUIRED 0 i TEMPERATURE CONTROL SPEC. IS TO INSTALL TEMPERATURE CONTROL WIRING IN CONDUIT. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL CONDUIT WITH k ' ;.. 1 PULL WIRE. MECHANICAL CONTRACTOR IS TO MAKE ALL FINAL WIRING CONNECTIONS TO THE TEMPERATURE CONTROL SYSTEM PER '"(5,00/0 VVT DAMPERS • , THE MANUFACTURER'S RECOMMENDATIONS. rj ,F 1 THE TENANT IS FURNISHING A TEMPERATURE CONTROL SYSTEM TO CONTROL THE ROOFTOP HEAT PUMPS. THE 16. MECHANICAL CONTRACTOR WILL PERFORM STARTUP ON ALL HVAC EQUIPMENT AND CONTROL SYSTEM. NO TEMPORARY HEATING OR \ "� �r� HVAC CONTRACTOR IS TO INSTALL THIS SYSTEM AND ALL OTHER CONTROLS REQUIRED/DISCRIBED BELOW. COOLING FROM HVAC UNITS WILL BE PERMITTED WITHOUT PROPER STARTUP PROCEDURES AS OUTLINED IN THE INSTALLATION ANDx . V' "r TEMPERATURE CONTROL SYSTEM j T—STAT, COMM BUSS, SENSORS \_/ �.1 STARTUP BOOKLETS PROVIDED WITH THE HVAC EQUIPMENT AND APPROVAL FROM TENANT'S PROJECT MANAGER. `` i d 2 ALL COMPONENTS LISTED HERE SHALL MEET THE LANDLORDS REQUIREMENTS. INSTALL ALL SENSORS IN A SMOKE DETECTOR(S) IN RETURN ELECT/FA • LOCATION THAT ALLOWS SERVICE ACCESS. TEMPERATURE CONTROL CONTRACTOR IS TO INCLUDE IN HIS 17, THE RETURN AIR PLENUM SHALL NOT CONTAIN ANY COMBUSTIBLES. AND/OR SUPPLY AIR DUCT CONTR, INSTALLATION AT NO ADDITIONAL COST ANY ITEMS REQUIRED BY THE LANDLORD NOT MENTIONED IN THESE DOCUMENTS THAT Will BE REQUIRED TO MAKE THIS A FULLY FUNCTIONAL SYSTEM. DIFFUSERS AND GRILLES • • 3 ALL 24 VOLT COMMUNICATION AND/OR SENSOR WIRING ASSOCIATED WITH THE HVAC CONTROL SYSTEM SHALL MECHANICAL CODED NOTES BE FURNISHED AND INSTALLED BY THE TENANT'S HVAC CONTRACTOR. ALL WIRING AND EQUIPMENT SHALL BE (j\ FIELD INSTALL DAMPER I N NECK OF DIFFUSERS. ACCESS FOR ADJUSTING BALANCING DAMPER MUST BE THRU FACE OF INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRIC CODES, LOCAL CODE AND DIFFUSER. DIFFUSERS/GRILLES FIRE DAMPERS • LANDLORD REQUIREMENTS. TENANT'S HVAC CONTRACTOR IS TO MAKE ALL FINAL WIRING CONNECTIONS TO THE TEMPERATURE CONTROL SYSTEM PER THE MANUFACTURER'S RECOMMENDATIONS. ALL WIRING IS TO BE IN ® EXISTING UTILITIES (DUCTWORK, PIP 1 NG, CONDUIT, ETC. ) TO BE RELOCATED BY LANDLORD. VERIFY NEW LOCATION WALL FIRE DAMPERS AND/OR CONDUIT. CONDUIT IS TO BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. WITH LANDLORD PRIOR TO BID. TYPE, SIZE AND ELEVATION I F KNOWN ARE AS NOTED. COMBINATION SMOKE/FIRE DAMPERS • • • 4 TEMPERATURE CONTROL CONTRACTOR IS TO INCLUDE ALL FINAL CONNECTIONS AND SYSTEM PROGRAMING FOR ® PRE—ASSEMBLED TEMPERATURE CONTROL PANEL/THERMOSTAT FOR RTU CONTROL INSTALLED BY HVAC CONTRACTOR IN THE H B K 0 THE TENANT'S EQUIPMENT AND FOR THE INTERFACE WITH THE LANDLORD'S SYSTEM IF REQUIRED. ELECTRICAL ROOM• VERIFY EXACT LOCATION OF CONTROL PANEL/THERMOSTAT WITH TENANT'S PROJECT MANAGER PRIOR EXHAUST FAN(S) • TO INSTALLATION. SEE TEMPERATURE CONTROL SPECIFICATION FOR ADDITIONAL INFORMATION. 3 SEQUENCE OF OPERATION 4 REMOTE ZONE SENSOR FOR RTU TEMPERATURE CONTROL INSTALLED AT 48" ABOVE FINISHED FLOOR. VERIFY EXACT CONSULTANT , LTD UNIT/BASEBOARD HEATER(S) • A. ROOFTOP UNIT SEQUENCE OF OPERATION Mechanical & Electrical Design Services LOCATION OF SENSOR WITH TENANT'S PROJECT MANAGER PRIOR TO INSTALLATION. SEE TEMPERATURE CONTROL 1. RTU FAN CONTROL: SPECIFICATION FOR ADDITIONAL INFORMATION. TOILET EXHAUST FAN(S) 40 ( 3 ) ( 1 ) THE SUPPLY FAN IS TO RUN CONTINUOUSLY DURING THE OCCUPIED MODE AND Will CYCLE ON AND OFF 5 THERMOSTAT FOR EXHAUST FAN CONTROL FURNISHED AND INSTALLED BY THE HVAC CONTRACTOR AT 48" ABOVE FINISHED 171 Charring Cross Drive S. �—/ `�—/ DURING THE UNOCCUPIED MODE BASED ON A CALL FOR HEATING OR COOLING. THE UNOCCUPIED SET FLOOR. VERIFY EXACT LOCATION OF SENSOR WITH TENANT'S PROJECT MANAGER PRIOR TO INSTALLATION. SEE Suite 113 POINT FOR COOLING WILL BE 85 DEGREES FAHRENHEIT AND 60 DEGREES FAHRENHEIT FOR HEATING. Westerville, Ohio 43081 TOILET EXHAUST DUCTWORK • • TEMPERATURE CONTROL SPECIFICATION FOR ADDITIONAL INFORMATION INFORMATION. 614,882.1199 WALL OR ROOF CAP 2. THERMOSTAT: FAX 614.882.1857 THE ADJUSTABLE ROOM THERMOSTAT WITH AUTOMATIC HEATING/COOLING CHANGEOVER SHALL CONTROL ® THERMOSTAT FOR CONTROL DAMPER FURN I SHED AND INSTALLED BY THE HVAC CONTRACTOR AT 48" ABOVE F I N I SHED LOW PRESSURE DUCTWORK • • THE SPACE TEMPERATURE BASED ON SET POINT, THE CONTROL OF THE OCCUPIED/ UNOCCUPIED SETBACK FLOOR. VERIFY EXACT LOCATION OF SENSOR WITH TENANT'S PROJECT MANAGER PRIOR TO INSTALLATION. SEE MODE SHALL BE THROUGH THE LIGHT SENSING FUNCTION OF THE THERMOSTAT. THERMOSTAT TO HAVE 5 TEMPERATURE CONTROL SPEC I F I CATION FOR ADDITIONAL INFORMATION. DEGREE DEADBAND. AIR BALANCE REPORT • AABC OR ®7 24"X24" CEILING ACCESS PANEL BY MECHANICAL CONTRACTOR, ACCESS PANEL TO BE USED FOR ACCESS TO EQUIPMENT D r o w i n s and d w r i l t e n material t t r i o l a e a r i n herein constitute n s i i t u t e o r i i n o l NEBB CERTIFIED LOCATED ABOVE THE CEILING. THIS CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT A MINIMUM UNOBSTRUCTED 9 appearing 4 T. SAFETIES: FREE AREA OF 3—FEET VERTICALLY AND 2—FEET HORIZONTALLY IN ALL DIRECTIONS AROUND EQUIPMENT IS MAINTAINED and unpublished work of the Architect and sop not be duplicated, THE UNIT SHALL BE TOTALLY DISABLED WHEN THE UNIT MOUNTED SMOKE DETECTOR IS ACTIVATED. P 1 P AS—BUILT DRAWINGS • PROVIDE REMOTE TEST STATION/ ALARM WHEN REQUIRED BY CODE. PROVIDE LANDLORD REQUIRED TO ALLOW FOR INSTALLATION AND MAINTENANCE OF EQUIPMENT. I F THIS FREE AREA CAN NOT BE OBTAINED, CONTACT u s e d or d i s c l o s e d w i t h o u t w r i t t e n c o n s e n t of t h e A r c h i t e c t SEQUENCE OR INTERFACE AS REQUIRED. THE TENANT'S PROJECT MANAGER IMMEDIATELY.(NOTE SMOKE DETECTOR AND ACCESSORIES TO BE PROVIDED BY ®11131.1 A R C N I T E C 1 - 10 1 0 ,. • FIRE ALARM CONTRACTOR. COORDINATE ALL WORK AND FINAL WIRING CONNECTIONS) /''\ ® INSTALL WALL TRANSFER GRILLE AT 12" AFF. ( 1 ) ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL ALL UTILITY POWER 0 SEE HVAC CODED NOTES FOR ADDITIONAL INFORMATION. 4, COOLING CONTROL: $A Q C TO THE EQUIPMENT, INCLUDING ALL TERMINAL CONNECTIONS. HA NT N 1 — FROM ALL T I AIR INTAKES. ALL CUTTING AND UPON A CALL FOR COOLING, THE FIRST STAGE OF COOLING WILL BE ENABLED AND WILL OPERATE UNTIL ® EXHAUST FAN TO BE INSTALLED ON ROOF. MA I A I 0 0 OM LL oU S DE 0 LANDLORD HVAC CONTRACTOR TO INSTALL ALL POWER WIRING AND THE SPACE TEMPERATURE IS SATISFIED. IF THE SPACE TEMPERATURE CONTINUES TO INCREASE THAN THE PATCH I NG OF ROOF SHALL BE BY THE LANDLORD'S ROOF I NG CONTRACTOR AT TH I S CONTRACTOR'S EXPENSE. I NCLUDE No. D o t e I s s u e CONTROL WIRING FOR ACCESSORIES, INCLUDING ALL TERMINAL SECOND STAGE OF COOLING WILL BE ENABLED (IF APPLICABLE). ALL COSTS IN BID AS DIRECTED BY THE G.C. 05/28/10 100 SET 5. HEATING CONTROL: CONNECTIONS, 10 SMOKE DETECTOR TO BE FURNISHED BY ELECTRICAL/FIRE ALARM CONTRACTOR AND INSTALLED BY MECHANICAL UPON A CALL FOR HEATING, THE FIRST STAGE OF HEATING WILL BE ENABLED AND WILL OPERATE UNTIL CONTRACTOR I N AN ACCESSIBLE LOCAT 1 ON I N THE RETURN AIR SECTION OF THE RTU. SMOKE DETECTOR SHALL BE 05/28/10 VT PACKAGE 0 HVAC CONTRACTOR TO FURNISH AND INSTALL LOW VOLTAGE THE SPACE TEMPERATURE IS SATISFIED. IF THE SPACE TEMPERATURE CONTINUES TO DECREASE THAN THE W I RED BY THE ELECTR I CAL/FIRE ALARM CONTRACTOR TO SHUT DOWN THE UNIT UPON SENSING SMOKE AND SIGNAL THE p7/02/10 100 COMPLETE SET CONTROL WIRING AND MAKE ALL TERMINAL CONNECTIONS. SECOND STAGE OF HEATING WILL BE ENABLED (IF APPLICABLE). LANDLORDS FIRE ALARM SYSTEM. REFER TO ELECTR I CAL/FIRE ALARM DRAWINGS FOR FURTHER INFORMATION. 07/28/10 LANDLORD SET 6. VENTILATION/ECONOMIZER CONTROL: 11 SUPPLY AND RETURN AIR DUCT CONNECTIONS TO RTU'S SHALL BE MADE FULL SIZE OF EQUIPMENT OPENING WITH GENERAL NOTE THE OUTSIDE AIR DAMPER SHALL BE OPEN DURING THE OCCUPIED HEATING AND COOLING MODES FOR FLEXIBLE DUCT CONNECTIONS AT UNIT. DUCTWORK SHALL EXTEND I N THE VERT I CAL DROP AND FOR A M I N I MUM OF 08/13/10 PERMIT/BID SET THIS SCHEDULE IS INTENDED AS A "QUICK" REFERENCE. ALL ITEMS LISTED HERE ARE SPECIFIED AND DETAILED CODE REQUIRED MINIMUM OUTSIDE AIR VENTILATION AND SHALL REMAIN CLOSED DURING THE 4'—0" HOR I ZONTAL FULL S I ZE AS SHOWN ON PLANS. ON THESE DRAWINGS. IF THE CONTRACTOR ENCOUNTERS ITEMS THAT ARE CONTRADICTORY THEN IT IS HIS UNOCCUPIED MODE. THE ECONOMIZER MODE IS ENTHALPY CONTROLLED AND WILL BE OPERATIONAL RESPONSIBILITY TO INFORM TENANT'S CONSTRUCTION MANAGER SO THAT THESE ITEMS CAN BE CLARIFIED WHENEVER COOLING IS REQUIRED AND THE OUTSIDE AIR ENTHALPY IS AT OR BELOW THE RETURN AIR 1© GENERAL CONTRACTOR TO PROV I DE A CONT I NUOUS SLOT I N CE I L I NG. TH I S SLOT 1 S TO BE USED FOR RETURN A I R. FOR THE CONTRACTOR. ENTHALPY, THE POWER EXHAUST WILL OPERATE WHENEVER THE OUTSIDE AIR DAMPER IS OPEN MORE SEE DETAIL ON ARCHITECTURAL PLANS. THAN 60 PERCENT. 13 THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL NEW REFRIGERANT LINES FROM THE DUCTLESS SPLIT AC 7, DISCHARGE AIR SENSOR: UNIT TO THE AIR COOLED DX CONDENSING UNIT ON ROOF AND MAKE FINAL CONNECTIONS. COORDINATE ROUTING OF THE DISCHARGE AIR SENSOR SHALL BE INSTALLED IN THE SUPPLY AIR SECTION OF THE ROOFTOP UNIT REFRIGERANT PIPING TO ROOF WITH LANDLORD PRIOR TO INSTALLATION. PROVIDE FIRE STOPP 1 NG AS REQU I RED BY LUMB I G RESPONSIBILITY SCHEDULE DOWNSTREAM OF THE COOLING COIL IN A LOCATION THAT IS ACCESSIBLE. CODE TO MAINTAIN FIRE RATING. FIELD VERIFY EXACT LOCATION OF PIPING CHASES PRIOR TO BID AND I NCLUDE AL L COSTS TO ROUTE PIPING TO THESE LOCATIONS IN BID. MECHANICAL CONTRACTOR SHALL PROVIDE A DETAILED SKETCH B. EXHAUST FAN UNIT SEQUENCE OF OPERATION. (ALL DEVICES FOR THIS EQUIPMENT SHALL BE FURNISHED TO THE HVAC EQUIPMENT SUPPLIER WITH THE ACTUAL ROUTING OF THE REFRIGERANT PIPING INDICATING THE FURNISHED BY INSTALLED BY WIRED BY AND INSTALLED BY THE TENANT'S HVAC CONTRACTOR.) D I STANCES AND ELEVATION CHANGES FOR S I Z 1 NG OF PIPING BY THE EQUIPMENT SUPPLIER. EQUIPMENT SUPPLIER ITEM - - RE—USE N/A REMARKS SHALL PROV I DE A RECORD COPY OF THE S I Z I NG TO THE ENGINEER. REFER TO MECHAN I CAL SPEC I F I CATION SECTION TENANT LANDLORD CONTR, LANDLORD CONTR. MECH, ELEC. EXISTING 1. EF-2 & 3 CONTROL: UPON A CALL FOR COOLING FROM THE SPACE MOUNTED THERMOSTAT, THE 15500, "REFRIGERANT PIPING" ON SHEET M4.2 FOR ADDITIONAL REQUIREMENTS. CONTR. CONTR. EXHAUST FAN SHALL START AND RUN CONTINUOUSLY, ONCE THE THERMOSTAT HAS BEEN SATISFIED, THE PLUMBING FIXTURES • • • FAN SHALL STOP. THERMOSTAT SHALL BE SET FOR 80 DEGREES FAHRENHEIT. 14 OUTDOOR CONDENSING UNIT TO BE INSTALLED ON THE ROOF. COORDINATE LOCATION WITH LANDLORD PRIOR TO STARTING WORK, SUPPORT UNIT ON PATE CURBS OR AS OTHERWISE DIRECTED BY LANDLORD. 2.EF-1 & 4 CONTROL: THE EXHAUST FAN IS TO RUN CONTINUOUSLY DURING THE OCCUPIED SAN, CW, HW, PIPING 4 • MODE. THE OCCUPIED AND UNOCCUPIED MODE WILL BE DETERMINED BY THE LIGHTING CONTROL 15 DASHED LINE AROUND HVAC EQUIPMENT REPRESENTS MANUFACTURER'S RECOMMENDED CLEARANCES FOR EQUIPMENT TIME CLOCK (PROVIDED BY ELECTRICAL CONTRACTOR). MAINTENANCE. IT IS THE MECHANICAL CONTRACTOR'S RESPONSIBILITY TO MAINTAIN SERVICE CLEARANCES THE FULL HEIGHT OF THE UNIT IN THIS AREA AND TO PROVIDE ACCESS TO THESE AREAS SUBJECT TO THE H&M CONSTRUCTION GAS PIPING • C. WT DAMPER SEQUENCE OF OPERATION. (ALL DEVICES FOR THIS EQUIPMENT SHALL BE FURNISHED AND MANAGER'S APPROVAL. I F FREE AREA CANNOT BE OBTAINED I N THIS LOCATION, I MMED I ATELY CONTACT H&M'S INSTALLED BY THE TENANT'S HVAC CONTRACTOR.) CONSTRUCTION MANAGER FOR FURTHER INSTALLATION INSTRUCTIONS. AS—BUILT DRAWINGS • 1. THERMOSTAT: 16 INSTALL I N—LINE FAN TO PROV 1 DE VENTILATION FOR ELEVATOR HO I STWAY. FURNISH AND INSTALL CEILING ACCESS A ROOM SENSOR SHALL CONTROL THE SPACE TEMPERATURE BASED ON SET POINT. THE CONTROL OF THE PANEL TO PROVIDE ACCESS TO FAN AND FIRE DAMPER. COORDINATE ACCESS PANEL REQUIREMENTS WITH ARCHITECTURAL OCCUPIED/ UNOCCUPIED SETBACK MODE SHALL BE THROUGH THE TEMPERATURE CONTROL PANEL. SPEC I F I CATIONS AND H&M'S CONSTRUCTION MANAGER. 2, COOLING CONTROL: Q FURNISH AND INSTALL REMOTE CABLE OPERATED BALANCE DAMPERS WITH CONTROLLER. INSTALL CONTROLLER INSIDE OF UPON A CALL FOR COOLING, THE VVT DAMPER SHALL MODULATE OPEN UNTIL THE SPACE TEMPERATURE SUPPLY A 1 R SLOT DIFFUSER I N AN ACCESSIBLE LOCATION. DAMPER AND CONTROLLER TO BE A YOUNG'S REGULATOR Project No. 44122/10038 REMARKS IS SATISFIED. WHEN THE SPACE TEMPERATURE IS SATISFIED THE VVT DAMPER SHALL MODULATE CLOSED BOWDEN CABLE #270-275 CONTROLLER WITH #5020—CC CONTROL DAMPER. TO THE MINIMUM POSITION, NM 18 FURNISH AND INSTALL A FIRE DAMPER WITH ACCESS DOOR IN DUCT PENETRATING FIRE—RATED PARTITION, LABEL 0 ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL ALL UTILITY POWER TO THE EQUIPMENT, INCLUDING ALL TERMINAL CONNECTIONS. Sco1e AS NOTED 3. HEATING CONTROL; ACCESS DOOR WITH 2" HIGH LETTERS DESIGNATING "F 1 RE DAMPER ACCESS". UPON A CALL FOR HEATING, THE VVT DAMPER SHALL MODULATE OPEN UNTIL THE SPACE TEMPERATURE IS SATISFIED. WHEN THE SPACE TEMPERATURE IS SATISFIED THE VVT DAMPER SHALL MODULATE CLOSED tO COORDINATE DUCT OPENINGS THRU MEZZANINE SLAB WITH LANDLORD AND G.C. VERIFY REQUIREMENTS PRIOR TO B I D iiii 0 PLUMBING CONTRACTOR TO INSTALL ALL UTILITY POWER AND CONTROL WIRING, INCLUDING ALL TERMINAL CONNECTIONS. SEE TO THE MINIMUM POSITION. AND INCLUDE ALL COSTS I N B ID AS D I RECTED BY G.C. D r o w s i l y: WDB/KH PLUMBING CODED NOTES FOR ADDITIONAL INFORMATION. • 3 PLUMBING CONTRACTOR TO FURNISH AND INSTALL LOW VOLTAGE CONTROL WIRING AND MAKE ALL TERMINAL CONNECTIONS. C§). STUB RETURN DUCT THRU SLAB I NTO CE I L I NG PLENUM. 04 DUCTWORK MAINS BELOW MEZZANINE TO BE ROUTED SUCH THAT IT DOES NOT CROSS OVER RECESSED CAN LIGHT /'� FIXTURES. 4 ) SEE PLUMBING CODED NOTES FOR ADDITIONAL INFORMATION, ' �i8'k \IOO���e� i �✓ 0 DISCHARGE AIR TEMPERATURE SENSOR INSTALLED IN SUPPLY AIR SECTION OF ROOFTOP UNIT, REFER TO TEMPERATURE irii SPECIFICATIONS FOR ADDITIONAL INFORMATION. Droving No. R GENERAL NOTE MECHANICAL NOTES THIS SCHEDULE IS INTENDED AS A "QUICK" REFERENCE. ALL ITEMS LISTED HERE ARE SPECIFIED AND DETAILED ON THESE DRAWINGS. IF THE CONTRACTOR ENCOUNTERS ITEMS THAT ARE CONTRADICTORY THEN IT IS HIS RESPONSIBILITY TO INFORM TENANT'S CONSTRUCTION MANAGER SO THAT THESE ITEMS CAN BE CLARIFIED FOR THE CONTRACTOR. 1 ,a NTS MECHANICAL NOTES _ 1 M2eald DESIGN WEATHER PARAMETERS RTU EQUIPMENT SCHEDULE _ , FAN SCHEDULE ACCESSORIES City Name Portland Location Oregon Result RTU-3&4 RTU- 1,2&7 _ RTU-5&fi j COOK TOTAL w � Latitude 45.6 Deg. Quan 1 1 _ 1 MOTOR VOLT/ W J a WEIGHT Longitude 122.6 Deg. FAN LOCATION FUNCTION MODEL C.F.M. E.S.P. W N 0 v ow REMARKS Elevation 39.0 ft Trane Model Number WSC090 WSC072 WSC120 H.P. PHASE W 14 D w CI. LBS. � � ZZ Wt,U �m � U� Summer Design Dry-Bulb 90.0 °F NUMBER W.G. c' ce Z Z 8 # a s Summer Coincident Wet-Bulb 67.0 °F Nomnal Tonnage r 7.5 Ton 6 Ton 10 Ton ap 0 <v W El Q> o MCI Summer Daily Range 21.6 °F ASHRAE 90.1 Yes Yes es TOILET JAN. ACE-0 • • • • • Winter g::ign Dry-Bulb 22A °F r..tuh at_:_.. EF-1 ROOF EXHAUST t Q4C1 QOH 200 0.375 300W 120/1 -- 50 Q 3 Winter lgn Wet-Bulb - -_ _ 18.4 •F SEER/EER aARI btuh/watt . ..11.10 11.40 11.20 Atmospheric Clearness Number 1.05 IPLV @ ARI IPLV 12.0 13.0 13.1 ('� 00 w w . .__..__ .._._u .._ Average Ground Reflectance 0.20 Refrig charge(HFC-410A) EF-2 CEILING ELEC,ckt 1 4 lb 13.8 12.0 9.8 HEAT CO RM NTR, GN-940 1245 0.5 1/2 120/1 • • -- • • 36 L..'J Current Data is... 2001 ASHRAE Handbook Design Cooling Months January to December yr r E -3 CE L I G LAN R G N-720 600 0.5 1/4 120/1 -- • • "- • • 36 E n f# 39.00 39.00 39.00 HEAT CONTR. Airflow application Downflow Downflow Downflow __ _- �._.. _. ....� .�: Wm EF-4 IN-LINE ELEVATOR GC-182 220 0,25 189W. 120/1 • • • • 12 0 0 US220 • Unit operating weight I lb 993.0 929.0 1407.0 VENTILATION m Gross Total Capacity MBh 92.53 77.26 122.34 rt HVAC LOAD CALCULATIONS i ...._._ _... _.. _.. ___ WASHINGTON SQUARE m Gross Latent Capacity MBh 20.50 16.77 29.02 REMARKS 3 O ALTERNATE MANUFACTURERS PENN, GREENHECK OR APPROVED EQUAL. Air Air System Information .1 Cooling EDB F 77.60 77.50 75.70 Air System Name H&M WASHINGTON SQ Number of zones 18 = "°- `° (� Square Equipment Class PKG ROOF Floor Area 20752.0 ft2 c Cooling BNB y F 63.90 63.60 63.40 2 FAN TO BE CONTROLLED BY THERMOSTAT, SEE TEMPERATURE CONTROL SPECIFICATIONS FOR ADDITIONAL ATE 1108 Air System Type CAVIRH Location Portland,Oregon a Cooling LDB F 57.29 57.52 56.52 INFORMATION, PORTLAND, OR 97'223 E 1-- Cooling LWB i F 54.24 54.11 54.03 ® FAN TO RUN CONTINUOUSLY IN THE OCCUPIED MODE. SEE TEMPERATURE CONTROL SPECIFICATIONS FOR ADDITIONAL Sizing Calculation Information to g_ .__,_..._.___.___.M_._. ,....___.. _..__... INFORMATION.and Space Sizing Method: M Ambient Temperature F 95.00 95.00 95.00 ���, RED a �. .. ....�..r_._.. ....__ ,. __...�. m__... m._...._�., _....,.._. O FURNISH FAN WITH VIBRATION ISOLATORS, FLEXIBLE DUCT CONNECTIONS AND SUPPORTS TO HANG FROM STRUCTURE. = E Output htg capacity r MBh 84.85 70.46 109.03 Zone CFM Sum of space airflow rates Calculation Months Jan to Dec Space CFM Individual peak space loads Sizing Data Calculated rn 2 Output htg capacity w/fanN N ; `+MT41 MBh 91.48 76.17 116.75 5 FURNISH FAN WITH SOUND ISOLATING INSULATED ROOF CURB. _ w. 0 Heating ambient temp i F 47.00 47.00 47.00 Central Cooling Coil Sizing Data a I Heating EAT F 65.00 65.00 65.00 ' Total coil load 43.6 Tons Load occurs at Jun 1500 3 Heating LAT , F 88.95 88.30 87.43 Total coil load ... 522.7 MBH OA DB J WB 89.0/67.0 °F th 8 Heating delta T i F 23.95 23.30 22.43 Sensible coil load 475.9 MBH Entering DB/WB 78.71 64.1 °F 8 rZ �._,.._..,_.. ._, . .._, ......, .w Coil CFM at Jun 1500 19993 CFM Leaving DB/WB 56.6/55.2 °F i- Heating capacity 18 kW 3ph@ 480 derate to unit volt 18 kW 3ph@ 480 derate to unit volt 27 kW 3ph@ 480 derate to unit volt Max block CFM 19993 CFM Coil ADP 54.1 °F ° Sum of peak zone CFM 19993 CFM Bypass Factor 0.100 Electric heat output r MBh 61.47 61.47 92.21 Sensible heat ratio 0.911 Resulting RH 50 % Electric heat air temp rise F 17.26 20.22 18.87 BTU/n 476.5 Design supply temp. 58.0 °F g. cfm AIR DISTRIBUTION DEVICES BTU/(hr-ft2) 25.2 Zone T-stat Check 18 of 18 OK Design Airflow cfm 3280 2800 4500 Water flow @ 10.0°F rise N/A Max zone temperature deviation 1.4 °F Outside Air Airflow cfm See Outside Air Requirments on M2.2 See Outside Air Requirments on M2.2 See Outside Air Requirments on M2.2 NOTES ' Design ESP F in H2O 1.500 1.500 0.950 5.DAMPERS SHALL BE OPERABLE FROM FACE ig 1,SYMBOL KEY - _._� .,,._._.... .,..._.._..., ..___ .w.-.,__ ._-.._.._.... ._._. .._..__._....._._......._.__.. "A" OPPOSED BLADE RECT. MANUAL BALANCING DAMPER FIRST LETTER: S-SUPPLY R-RETURN E-EXHAUST ` ' Indoor ir>tr operating power bhp 2.12 1.74 2.75 "B" ROUND MANUAL BALANCE DAMPER IN BRANCH DUCT, .. Supply Fan Sizing Data ... _... _.._.,_.�_.. , ., _...,_,,.., .,._.,,.. SECOND LETTER: D-DIFFUSER R-REGISTER G-GRILLE "C" ROUND OPPOSED BLADE DAMPER IN NECK TITUS yD-75 s'. Indoor srpm rpm 999 1193 1608 2,CATALOG NUMBERS REFER TO TITUS AIR DEVICES. "0" YOUNG'S REGULATOR, DPR MODEL # 5020-CC W/270-301 s ALTERNATE MANUFACTURERS: PRICE. KRUGER OR APPROVED EQUAL. "E" FIRE DAMPER IN NECK I k k.Actual max CFM 19993 CFM Fan motor BHP 12.00 BHP Supply fan/drive/type/motor x Oversize motor ph 3 Oversize motor ph 3 Standard drive motor .� ,.� r$ x Standard CFM 19964 CFM Fan motor kW 8.95 kW ._......,._..,_...N_. 3,PROVIDE DIRECTIONAL BLOW FOR AIRFLOW OTHER "F" SLIDING BLADE DAMPER IN NECK 2 2 Feild supplied drive kit required I None None None THAN 4-WAY, SEE DETAIL ON SHEET H4 6. BORDER STYLE- \ \.. `1 460/60/3 "A" SURFACE MOUNTED . { Actual max Voltage 460/60/3 460/60/3 4, FINISH- � ��. h P; Outdoor Ventilation Air Data ..._. ' "A" - WHITE, "B" LAY-IN, PROVIDE WITH TITUS MODEL TRM FRAME FOR CFM/person 15,89 CFM/person erson MCA { A 49.00 48.00 fi6.70 "B" - WHITE - G.C. TO FIELD PAINT DRYWALL CEILING MOUNTING, SEE DETAIL ON SHEET H4 ' ,�,.. " Design airflow CFM 4009 CFM P p ....,�_, ,_... ....,._,�.�.a...r.....�..__,..�nw,w�_.._.......a,._ry...�..._�rn,__ �..��._...M..,�._�r-,.�. » CFM/ft2 0.20 CFM/ft2 MOP 50,00 50,00 70,00 TO MATCH CEILING OR WALL WITH ENAMEL FINISH, C LAY-IN FRAME FOR T-BAR CEILING. A� "C" FLAT BLACK. "0" 2A-XX FRAME AND BORDER WITH MP-39 INSULATED BOOT SYMBOL CATALOG SIZE MOUNTING MATERIAL FINISH DPR. BORDER REMARKS Zone Sizing Data NUMBER MOD. NECK CINIG OTHER STEEL ALUM. STYLE Maximum Design' Minimum Time Maximum Zone. LANDLORD MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL TRANE ROOF MOUNTED HVAC UNITS. THE UNITS SHALL BE FURNISHED ALDES (� n('�� Cooling Air Air of Heating Floor WITH THE FOLLOWING ACCESSORIES: _1 SR-862 14"0 2 • • B F A O V�J Sensible Flow Flow Peak Load Area Zone Zone Name (MBH) (CFM) (CFM) Load (MBH) (ft') CFM/ft' 1. ECONOMIZER WITH DIFFERENTIAL ENTHALPY CONTROL. SD-2 TMS 24"X24" 12"0 • • B B C Zone 1 21,4. 1419 1419 Jan 2100 0.0 2700.0 0.53 2. FACTORY STANDARD POWER EXHAUST. Zone 2 65.0 4307 4307 Jan 2100 0.0 2754.0 1.56 3. FACTORY SMOKE DETECTOR INSTALLED iN RETURN AIR SECTION OF UNIT COMPATIBLE WITH LANDLORD'S FIRE ALARM SYSTEM. SD-3 TMS 24"X24" 10"0 • • B B C Zone 3 29,5 1951 1951 Jan 2100 0.0 2355.0 0.83 4. NON FUSED DISCONNECT W/ THRU THE BASE ELECTRICAL CONNECTIONS. H B K Zone 4 8.7 577 577 Jan 2100 0.0 832.0 0.69 5. PHASE MONITORS. SD-4 TMS 24"X24" 8"0 • • B B C Zone 5 9.3 614 614 Jan 2100 0.0 191.0 3.21 6. 14" HIGH ROOF CURB. Zone 6 1.8 122 122 Jan 2100 0.0 129.0 0.94 7. 1 YEAR TOTAL UNIT PARTS WARRANTY, 10 YEAR COMPRESSOR. SD-5 TMS 24"X24" 6"0 • • B B C CONSULTANTS, LTD Zone 7 2.6 171 171 Jan 2100 0.0 182.0 0.94 8. FIELD SUPPLIED DRIVES AS REQUIRED BY EQUIPMENT MANUFACTURER TO MEET SPECIFIED CONDITIONS. Mechanical & Electrical Design Services Zone 8 1,8 122 122 Jan 2100 0.0 285.0 0.43 SD-6 TMS 24"X24" 10"0 • • B B A Zone 9 52.9 1818 1818 Jun 1400 12.2 2684.0 0.68 CONTRACTOR iS RESPONSIBLE TO COMPLETELY INSTALL THE LISTED ACCESSORIES PER MANUFACTURER'S RECOMMENDATIONS, INCLUDING ALL Zone 10 50.2 2907 2907 Jun 1400 12.9 2534.0 1.15 ELECTRICAL AND ACCESSORY CONTROL CONNECTIONS. SEE TEMPERATURE CONTROL SPECIFICATIONS FOR ADDITIONAL INFORMATION 171 Charring Cross Drive S. - Zone 11 53.2 3081 3081 Jun 1400 15.9 3132.0 0.98 Suite 1B PERFORMANCE ABOVE BASED ON TRANE. APPROVED MANUFACTURERS: CARRIER, LENNOX OR ENGINEER APPROVED EQUAL. Zone 12 8.4 486 486 Jun 1400 3.1 610.0 0.80 Westerville, Ohio 43081 0.80 SL-1 FL-15- 4 LONG (1)$"0 • • B D D (�O 614,882.1199 Zone 13 20.8 715 715 Jun 1400 7.0 1372.0 0.52 ALL UNITS: MECHANICAL CONTRACTOR TO FURNISH THREE SETS OF STANDARD AIR FILTERS - CONTRACTOR TO REPLACE FILTERS JUST PRIOR 1-66-HT 2-SLOT �✓ FAX 614,882.1857 Zone 14 4.4 228 228 Jun 1400 0.6 114.0 2.00 TO AIR BALANCE AND ONCE AGAIN AFTER FINAL STORE CLEANING IS COMPLETE. Zone 15 5,8 335 335 Jun 1400 0.5 108.0 3.10 Zone 16 9.2 315 315 Jun 1400 3.0 590.0 0.53 Zone 17 4.5 155 155 Jun 1400 0.3 56.0 2.78 RG-1 350-RL 24"X12" 22"X10" • • B B C Zone 18 19.5 670 670 Jun 1600 0.6 124.0 5.41 Drawings and written material appearing herein constitute original DESIGN COOLING DESIGN HEATING OUTSIDE AIR REQUIREMENTS RG-2 350-RL 24"X12" 22"X10" • • B B A and unpublished +ark of the Architect and mop not be duplicated, COOLING DATA AT Jun 1500 HEATING DATA AT DES H1G . LEVEL ROOM - FLOOR ASHRAE 62 OUTSIDE SYSTEM ACTUAL REMARKS used or disclosed without written consent of the Architect COOLING OA DB/WB 89A'°F/67.0°F HEATING OA DB/WB 22.0°F 118,4"F ' PURPOSE AREA AIR REQUIREMENTS NUMBER OUTSIDE AIR RG-3 350-RL 24"X24" 22"X22" • • B B C c M B H ARCHITECT - 2 0 1 0 . SO. CFM PER CFM CFM PER Sensible Latent Sensible Latent FT. S0. FT READ, UNIT ZONE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (13111/hr)' FIRST LEVEL 1ST SALES 8285 0.20 1,657 RTU-1 FIRST LEVEL 580 Q A Q C Window&Skylight Solar Loads 0 ft2 0 0 ft2 - - • FIRST LEVEL 1ST FTG ROOMS 832 0.20 166 RTU-2 FIRST LEVEL 580 . : -;;:::: 2 0 - - FiRST LEVEL 1ST DISPLAY WINDOW 311 0.00 0 RTU-3 FIRST LEVEL 690 EG-1 350-RL 12"X12" 10"X10" • • B C A N o. D o I e I s s u e 11324 ft2 74715 - 11324 ft2 51083 - TOTAL 1 823 TOTAL 1,850 05/28/10 100% SET Window Transmission 0 ft2 0 - 0 ft2 0 • EG-2 350-RL 24"X12" 22"X10" • • B B C Skylight Transmission 0 ft2 0 - 0 ft2 0 - 05/28/10 VT PACKAGE Door Loads 0 ft2 0 - 0 ft2. 0 - MEZZ LEVEL I MEZZ I SALES I 8960 I 0.20 1,792 RTU-5 MEZZ LEVEL 680 Floor Transmission 0 ft2 0 - 0 ft2 0 - TOTAL 1,792 RTU-6 MEZZ LEVEL 690 EG-3 350-RL 24"X24" 22"X22" • • B B C 07/02/10 100% COMPLETE SET I Partitions o ft2 0 - 0 ft2 0 - RTU-7 MEZZ LEVEL 430 07/28/10 LANDLORD SET Ceiling 0 ft2 0 - 0 ft2 0 • SECOND LEVEL 1 2ND I NONSALES I 2364 I 0.15 355 TOTAL 1,800 Overhead Lighting 24247 W 71801 - 0 0 - TOTAL 355 / 1708s w 54019 - 0 0 - TG-1 350-RL 24"X12" 22"X10" SIDE • A B A 6 08/13/10 PERMIT BID SET Task Lighting RTU-4 SECOND LEVEL 360 WALL Electric Equipment 12340 W 40220 - 0 0 - TOTAL 360 People 251 48333 50117 0 0 0 . . . Infiltration - 0 0 - 0 0 Miscellaneous - 36256 0 - 0 0 Safety Factor 10%/10% 32534 5012 10% 5108 0 Total Zone Loads 38842 55128 54191 . 0 38843 55128 - 54523 LL a MISC. ELEC. WATTS FOR COMPUTER LOAD EST. Zone Conditioning - 23 Plenum Wall Load 0% 0 - 0 0 - ROOMS Plenum Roof Load 0% 0 - 0 0 - EQUIPMENT N.E.C. H.V.A,C. REMARKS, n FIELD FABRICATE INSULATED BOOT. DUE Plenum Lighting Load 0% 0 - 0 0 - NAME ELEC. LOAD SALES NON SALES DUCTLESS SPLIT SCHED. O NATIONAL ACCOUNT CONTACT: JOHN HARRELL, �.:J TO LENGTH, SOME DIFFUSERS WILL HAVE Return Fan Load 19993 CFM 0 - 19993 CFM 0 - REQ. WATTS QTY. WATTS QTY. WATTS 1-800-255-7749. DIFFUSER TO BE PROVIDED MULTIPLE BOOTS/CONNECTIONS. SEE Ventilation Load 4069 CFM 56978 -8409 4069 CFM 202173 0 ___ THE CONTRACTOR TO FURN 1 SH AND I NSTALL WHERE WITH PERFORATED EQUALIZING GRID, INLET FLOOR PLAN FOR NUMBER OF Supply Fan Load 19993 CFM 30533 - 19993 CFM -30533 - SOUND SYSTEM 1800 W. 1800 W. --- 1 1800 SHOWN ON PLANS A DUCTLESS SPL I T AC SYSTEM, REDUCTION SPIGOT AND SLIDING BLADE DAMPER. BOOTS/SUPPLY CONNECTIONS. Space Fan Coil Fans - 0 - - 0 - CASH REGISTER 275 W. 275 W. 7 1925 --- --- SANYO MODEL #12KLS71 . INSTALL WITH PROPER 2 SEE FLOOR PLAN FOR CONNECTION SIZE TO FURNISH WITH HARD CEILING HANGING Duct Heat Gain/Loss 0% 0 - 0% 0 - SERV I CE CLEARANCE AREA AS RECOMMENDED BY CLIPS AND TYPE SX END CAPS. TRANSITION SPIGOT FURNISHED. � >>Total System Loads ::::. 46720. 226163 0 PC COMPUTER 360 W. 360 W. --- --- 4 1440 MANUFACTURER. 3 FURNISH REDUCER TO DUCT SiZES SHOWN. �:J INSTALL BOTTOM AT 12" A.F.F.. Central Coolin Coil - 46727 - 0 0 O Cooling Zone Heating Unit Coils - 0 - - 226064 - PRINTER 120 W. 40 W. --_. NM OM OM 2 80 OS-1 >>Total Conditioning 476934 46727 226064 0 I NDOOR UN I T SPEC I F I CAT I ONS: SANYO MODEL , Key: Positive values are clg loads Positive values are htg loads TCP PANEL 250 W. 250 W. --- --- 1 250 fKS 12 71 , 294 C.F.M, SUPPLY AIR, 120 V. , 1 Negative values are htg loads Negative values are toads PH. , 60 HZ. UNIT SHALL BE FURNISHED WITH VVT SCHEDULE SENSORMATIC 360 W. 360 W. 1 360 --- ___ INTEGRAL THERMOSTAT, CONDENSATE PUMP, MOUNT I NG BRACKET AND TWO SETS OF STANDARD JACKSON INLET DESIGN MINIMUM REMARKS TELE. SYSTEM 200 W. 120 W. 1 120 F I L TERS. CONTRACTOR TO REPLACE F I L TERS MARK SYSTEMS SIZE CFM CFM VOLT/PH , _ PRIOR TO TURNING OVER TO OWNER. INSTALL MODEL NO. Project M o. 44122/10038 DRINKING FOUNTAIN 165 W. 165 W. --- --- I 165 UNIT ABOVE DOOR. SET T-STAT AT 85' . FRIG/MICROWAVE 300 W 300 W. --- --- 1 300 ACCU-1 WT-1 ZD-XX 10"0 330 160 120V/14 • ØQ Q Q , OUTDOOR CONDENSING UNIT SPECIFICATIONS: Scale AS NOTED ___ _-_ SANYO MODEL #CL 12 71 , 120 VOLT, 1 PHASE, 60 WT-2 ZD-XX 10"0 260 120 120V/10 4;) 0 4i)FIRE ALARM PANEL 200 W. 200 W. 1 200 HZ. NOMINAL 0.75 TON CAPACITY, 17.0 SEER SECURITY PANEL 200 W. 200 W. ........... -..- 1 200 RATING. UNIT SHALL BE INSTALLED ON THE ROOF WT-3 ZD-XX 12"0 600 250 120V/10 Q QQ D r o•e B y: WDB/KH WHERE SHOWN. FURNISH AND INSTALL LOW • LAN PC'S 360 W. 360 W. --- --- 2 720 AMBIENT KITS AND TIMED-OFF CONTROL KITS ON ALL UNITS. INSTALL UNIT WITH PROPER ___ SERVICE CLEARANCE AREA AS RECOMMENDED BY MONITORS 180 W. 100 W. REMARKS J:\2010 Jdx\10o38\us22ou22..g A. 4 400 MANUFACTURER. ig. IRONS 1000 W. 750 W. --- --- 2 1500 1. VVT DAMPER TO BE COMPATIBLE WITH CONTROL SYSTEM. SEE TEMPERATURE CONTROL 4 INSTALL REFRIGERANT PIPE BETWEEN UN I TS AS SPECIFICATIONS FOR ADDITIONAL INFORMATION, o TRANSFORMER 35 KVA 790 W. --- --- 2 1580 RECOMMENDED BY MANUFACTURER. 2. FURNISH WITH HEATING/COOLING AUTO CHANGEOVER THERMOSTAT. MODEL Z-200-T. D r o v i n g N o. 3. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. MECHANICAL TRANSFORMER 45 KVA 1300 W. --- --- 1 1300 4. PROVIDE UNIT WiTH CONTROL TRANSFORMER. ELECTRIC CONTRACTOR SHALL PROVIDE A 120 V. 1 CALCULATIONS PH ORCUIT TO BOX, TOTAL ELEC. E(�11P, 2285 10055 5. ALTERNATE MANUFACTURER'S; CARRIER AND LENNOX OR APPROVED EQUAL. AND SCHEDULES I ,g NTS 1 1 MECHANICAL CALCULATIONS AND SCHEDULES _ M22 VOLUME DAMPER WITH NOTE: DAMPER HANDLE TO BE LOCKING QUADRANT. PROVIDE WITH 3" EXTENDED INSTALLED MAXIMUM OF SHAFT, HANDLE AND COLLAR 3'-0" ABOVE CEILING. 71/%/14/1/1 TO S.A. MAIN SHT. MTL. ELBOW REQUIRED SECURELY TAPE VINYL FLEX . . W/ MIN. OF INSULATED (2)DUCT CONTINUOTO SHT US MTL WRAPS OF DUCT ROUND DUCT TAPE. STRAP CLAMP OVER FLEX DUCT INSULATION & VINYL TO SHT. MTL. TAPE INSULATION TO DUCT 18" LONG ORANGE MARKER TO FORM A GOOD SEAL TAPE ATTACHED TO DAMPER 1111 TO IDENTIFY LOCATION 8" LONG SHT. MTL. SECTION SECURED US220 TO DIFFUSER COLLAR W/ MIN. (3) SHT. MTL. SCREWS, DUCT TAPE AND MASTIC. W S I TON SQUARE INSULATED FLEXIBLE CONNECTION (MIN. 3 FT., MAX. 4 FT.) TRANSITION FROM DUCT SIZE TO NM SW WastiNitori Square 111 DIFFUSER NECK SIZE AS NECESSARY SUITE HOB FIRE DAMPER WHERE CR 9 INDICATED ON PLANS. THERMAL INSULATING BLANKET REQUIRED FOR FIRE RATED CLAIM RED 1 I N.-4.1 CEILINGS ONLY. INSULATION REQUIRED FOR NON—FIRE RATED DRYWALL CLG. STEEL MOUNTING FRAME REQUIRED FOR DRYWALL CEILINGS. CEILING INSTALLATION SEE DETAIL THIS SHEET. DIRECTIONAL BLOW PLATE CLIPPED ON DIFFUSER RODS. SEE NOTE NOTE: ALL DIFFUSERS ARE 4—WAY BLOW UNLESS BELOW. NOTED OTHERWISE. PROVIDE OPTIONAL SUPPLY AIR DIFFUSER DIRECTIONAL BLOW TO CONVERT (LAY—IN FRAME)— DIFFUSER FROM STANDARD 4—WAY TO 1—WAY, 2—WAY OR 3—WAY BLOW AS DESIGNATED ON • PLANS BY SHADED AREA. NTS NTS NTS - , NOT USED 9 NOT USED 24"x24" & 12"X12" DIFFUSER MOUNTING DETAIL 3 dJ , - °k r r.:- , f :t k r .,' "V '' RATED WALL 1" FIBERGLASS INSULATION THRU WALL ONLY TO S.A. MAIN i --- (E) OR (N) PIPE . INSULATED SHEET .. — i,_, . I, METAL SUPPLY BOOT. / ■ INSULATED 4----- ROUND DUCT 1-1 B I( P (3 0 (1 d Ehlilh ill 111Ili I' / 111* CONSULTANTS, LTD Mechanical & Electrical Design Services 3M BRAND FIRE BARRIER F _ CP25WB+ CAULK OR EQUAL. ; ,. CABLE OPERATED VOLUME DAMPER + 171 Charring Cross Drive S. COMPLETELY FILL ANNULAR OPPERABLE FROM FACE OF SLOT I SHT, MTL. ELBOW REQUIRED Suite 16 SPACE BETWEEN PIPE AND DIFFUSER (UNLESS VOLUME 111 Westerville, Ohio 43081 . . DAMPER H WN O N PAN _____M FAx 614,882,1857 WALL AND LEAVE A MIN. DA E S 0 0 PLANS ----_.� 5/8" BEAD AROUND BOTH 1 �+ ___— SECURELY TAPE VINYL FLEX DUCT OUTSIDE FACES OF WALL o TO SHT. MTL. W/ MIN. OF (2) _ CONTINUOUS WRAPS OF DUCT TAPE. STRAP CLAMP OVER FLEX CEILING DUCT INSULATION & VINYL TO SHT. Drowings and written material appearing herein constitute original MTL. TAPE INSULATION TO DUCT and unpublished pork of the Architect and may not be duplicated, UNINSULATED — UL SYSTEM WL 1001. INSULATED — UL SYSTEM WL 5039 TO FORM A GOOD SEAL. used or disclosed without written consent of the Architect ©MBH ARCHITECT - 2010 INSULATED FLEXIBLE LINEAR DIFFUSER CONNECTION (MIN. 3 FT., MAX. IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 4 FT.) INSTALL FULLY Q A 0 C NOTE: INSTALLATION TO FOLLOW UL SYSTEM WL 1001 OR WL 5039 STRETCHED, PERMANENTLY AND BE A UL TESTED ASSEMBLY. SEAL CABLE SEALED AND SUPPORTED TO N o. D o t e I s s u e OPERATOR AT PREVENT KINKING AND SHARP PENETRATION OF TURNS. 05/28/10 100% SET SUPPLY AIR BOOT. 05/28/10 VT PACKAGE 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET PIPE THRU FIRE WALL PENETRATION DTL NTS NTS NTS _ 8 NOT USED _ 5 LINEAR SLOT DETAIL _ 2 08/13/10 PERMIT/BID SET CONICAL FITTING SEAL AIRTIGHT W/MASTIC WALL BOLT TO SLEEVE (TYP.) TO S.A. MAIN SHT. MTL. ELBOW REQUIRED r—).- L11 .__,... LECcUTRTE0LYsTHATP. E VINYL FLEX ATTACH DAMPER TO ; zEa! 0 ROVI SS DOOR IN �EUCTI,ANGULAR es• MTL. W/ MIN. OF SLEEVE AS RECOMMENDED IN SULATED G OF (2) CONTINUO US WRAPS OF DUCT a= 1€ BY MFGR. �.- DAMPER FUSIBLE LINK. ! ROUND DUCT TAPE. STRAP CLAMP OVER FLEX 41111111111 jr,ip 3 F AI \ ,/ DUCT INSULATION & VINYL TO SHT. i RECTANGULAR DUCT ./ MTL. TAPE INSULATION TO DUCT ' TO FORM A GOOD SEAL STEEL BLADES WITH 1111111 1111111111 INTERLOCKING JOINTS 'N -4--ROUND --+- 8" LONG SHT, MTL. SECTION SECURED AIR FLOW ■ DUCT AIR FLOW 45' TO DIFFUSER COLLAR W/ MIN. (3) SHT. FUSIBLE FIRE LINK SADDLE TAP MTL, SCREWS, DUCT TAPE AND MASTIC. A CONCENTRIC TRANSITION G ROUND TO ROUND E RECTANGULAR TO ROUND g RECTANGULAR TO ROUND INSULATED FLEXIBLE CONNECTION o (MIN. 3 FT., MAX. 4 FT.) DUCT <j 0 — MAX. 45' DIVERGING, ' , 60' CONVERGING SLIDING BLADE DAMPER FIELD FIRE DAMPER WHERE I INSTALLED. PURCHASED WITH DIFFUSER. MN VANE5 PRE—ASSEMBLED ON RUNNER PLATES 1.,...•.0 MOUNT SLEEVE IN BLDG. INDICATED ON PLANS CONSTRUCTION, SLEEVE USE GALVANIZED VANES FOR GALVANIZED l TRANSITION "SPIGOT" FROM DUCT SIZE TO Project No. 44122/10038 TO BE OF GAUGE AS ` OR ALUMINUM DUCTS INSULATION REQUIRED �i DIFFUSER NECK. PURCHASED WITH DIFFUSER. . RECOMMENDED Y MF R PLATE SAME GAUGE AS DUCT FOR NON—FIRE RATED ..—iu iiiiiiiiii.---B G � 0 0 E ED � S c a l e AS NOTED FOR U.L. APPROVAL ""—L`"") MAIN DUCT CEILINGS. AND CODE COMPLIANCE - • / r ----� THERMAL INSULATING BLANKET MI DUCT CONNECTION TYP. �� i�I' : : I:0FUSER REQUIRED FOR FIRE RATED 0 r o n n 8 r: WDB/KH A, ( ) �(" CEILINGS ONLY. AIR FLOW ++T � � �� 14 ROUND STANDARD ACCESS TO NECK MOUNTED ' e �"' SIZE. BALANCING DAMPER IS THROUGH RETAINING ANGLES, BRANCH SIZE AS RECOMMENDED DUCT J:\2010 Jobs\1oo38\US22an23.d.g � 3 t/4" 1 1/2" , THE DIFFUSER FACE. ^t BY MFGR. R=2 Y.; 11111,11111 miim.'✓ Droving Na. o ECCENTRIC TRANSITION RECTANGULAR TO RECTANGULAR DUCT SIZE OVER 36"x36" DUCT SIZE 36"X36" OR \----1 0 — MAX. 30' (EXCEPT 45' UNDER MECHANICAL SQ. ELBOW WITH TYPE "A" SQ. ELBOW WITH SINGLE 0 IS PERMITTED AT ROUND TO DOUBLE THICKNESS VANES THICKNESS VANES DETAILS ' FLAT OVAL) TURNING VANE DETAIL 1 NTS NTS "ALDES" NTS FIRE DAMPER DETAIL _ 7 DUCT DETAILS _ 4 ALDES DIFFUSER MOUNTING DETAIL _ i M 2 .3 • . 0 1 0 09 • DD BB •• AA 0 0 • 0 -......... US220 WASHINGTON SQUARE I I I I I I I I 9695 S.W. Washingtal Scpwe SUITE HOS I I I I I I I I PORTLAND. OR 9722 CLAM RED I I I I I I I I I I Ii _ _ _ _1 _ _ _ _1 _ _ _ _1 _ _ _MUM.———----—— —.MINN it—. _ _ Ili -ft-iiiiiiii-miiiiiiiialE- --------iii. " ,..1iiiiii ---Wri4emil 1.4"- PKIE 1 • I I I 1 I ii II 1 I1111 1 / __I I 1111 I ,Ii I �L I , 1 I ► \ / 1) _ i �■— -- -- — „ ii _-- -- —_ --- ariiiI!mg _ �. I1�NII = = HINI I.. = In Fill - — il ' _ _ — 38_ __I Vi! . �- I -1 I I I I II I I I I ., ELEVATOR I I M SAFES I I ,g , : ELEVATOR r_ viii I [. ..j I AI / _ � fJ12t ) , , ,, L — r ROOM tr• I CO I gill- • y it I -/ F -��� I I , g -,. 1 I 1 1 -N., I I 1 / 0 ! _ I I i AI . 0 -- o \ / _ SALES 0 • ► �REA p /'�fl - SALES I / 11 ii I ..:, 7 1 . r - -- ,. AREA X :, I I/ El I L I LL . i111j ,,.. : I I i; i \ . 1 iiiimmen ImANC 1 : ,„ 1 i , / 1 i H B K 0 __ _:„ 1---------- , — CONSULTANTS, LTD ifile.N.— J :r Mechanical Sc Electrical Design Services t_ \ IF / \-- ..., lill elan I I I I I I �� _-- `l li , suite 1e ri��� ���� ❑ 171 Charring Cross Drive S. 1 I Ili 1 I Westerville, Ohio 43081• I • I , I ( I :: / \ I 614,882.1199 1 1 1 I FAX 614,882,1857 FITT NG 1 I '� SALES I " / \ II ROOMS I SALES I I I AREA '' I I I ►I I AREA IL I I / \ 1 I I r . I iii �,I 1 I Dro►ings and irilten material appearing herein constitute original ► '=' I �'I 1, I ��t►I I ;; / 1 , and unpublished 'lark of the Architect and may not be duplicated, I I I I used or disclosed 'filbert mitten consent of the Architect cc 7 o iiii 141BH ARCHITECT 2010 1 I I ill g I I�L�g ► w41 o 1 ill 0 1 i J ,�' I I TIMIIIIII QAQC N_ N I, ► HIV► ►1 < t_ __. _ L J I No. Dote Issue Ing 1.. 1 — _ — -- -- -- - - - --_ _ -. - -- :: -�. — — - - 4. — — — 0% SET - — _ _ _ -- -- _ .. - 05/28/10 1 a I 3 6 05/28/10 VT PACKAGE I I I I I I ► 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET 08/13/10 PERMIT/BID SET MI Project No. 44122/10038 IIIIIIIIIIIIII Score AS NOTED DroviBy: WDB/KH SEE SHEET M3.1c FOR PLUMBING GENERAL NOTES 2' AND PLUMBING CODED NOTES. N , X2010, \100 1 1 iii o Drawing No. , PLUMBING PLAN 4 FIRST LEVEL VERIFY ALL CONDITIONS IN FIELD PRIOR TO BIDS. 3 PLUMBING PLAN - FIRST LEVEL 1/$�-�-O 1 DECO/PROCESSING lit&ill AREA ,0 6 DD 6 BB AA 0 0 ti HARDWARE _ _ �� .N US220 -M iiMiir I I I I I I I WASHINGTON SQUARE eltr _ . ._. . - — . . ELECTRICAL H LECTRICAL S.W. Was ROOM cy Al SUITE HOB 1 PORTLAND, OR 97223 ADMIN I JANITOR • ROOM = ' CLOSET CLASS RED II • - I I I I I I ' TOILET MEETING/ ►r w�.�.�s ommmo mmom�• SECURITY *-I_ PI I , M . � I rl I i o ROOM I I I _ _ -- 1.._._M_.__+____M_._1 _ ii'I ,1 SP ASH 1 1 I , � 1 I BL•CK I I I RTU u I LOUNGE TOILET 1 –-1/ ROOM _ I I (T ') 1 111111110117., 4• — I I �� L _ J 1. I g ii , a sst-1- II It I I ♦ I ! 1 1 1 ,, I' RTU �— — — — --1 I _ RTU = (TYPI ��,�-J ( I I -r �' , l ELEVATOR 1 — — % jj _ _ ___ _ _ __ _ _ _ _ _ _ _ _v , , I _ II - —'� 11SALES AREA rii ii .�u iiiu uiur Ammo. PummilW 4 11,...___, I 3.1B I F.1 SALES, ROFITO S IL 111.4 ;Fillk)01:1411 11 1 I I I 11 - I Al A 11 1 Ir RTU I I �1! 5 I RTU II! '� ►=.►z.►_ , I I 6 111 CI, H B K _ - II 17"411111M161 .0321.►= Ilrg* — — I I — — 1:0 ___ _ 41.- -- ........ .--I ....... •a . •- :�min on L J CONSULTANTS, LTD I r I RTU 1 IIIII 11111111111 WJ INN,,.rr! :; N INIt Mechanical & Electrical Design Services I1 I 1Wi l L _ J 171 Charring Cross Drive S. Suite SALES Westerville, Ohio 43081 III I I 1. I SALES I S I I AREA t' -� FAX 8614.882.1857 4] 1 I-" "' — ,' I SALES IIk 1 AR I 11:1 k1 I MCIDrawings and written material appearing herein cansfitute original I I i I I 1iii I I I I and unpublished work of the Architect and soy not be duplicated, '� 1 L _ _1 used or disclosed without written consent of the Architect ill C)1481.1 ARCHITECT - 2010 iII o A a C I 1�1► / 4 In I 1I— —' I I No. Dote Issue— ', .� _ ■_ _. - _ _ . _ — 36 05/28/10 100% SET 05/28/10 VT PACKAGE 07/02/10 100% COMPLETE SET 07/28/10 LANDLORD SET 08/13/10 PERMIT/BID SET • 4 Project No. 44122/10038 Stole AS NOTED Oro•sBy: WDB/KH SEE SHEET M3.1c FOR PLUMBING GENERAL NOTES a N "2010,bbs`10038\US220Y31bdag s rg AND PLUMBING CODED NOTES. J'! III O Droving No. - li VIP PLUMBING PLAN MEZZANINE LEVEL VERIFY ALL IN FIELD PRIOR TO BIDS. I 1/8 —1-0" 1 PLUMBING PLAN - MEZZANINE LEVEL _ M3 .1b PLUMBING GENERAL NOTES 7Va lili 1, PLUMBING CONTRACTOR SHALL VISIT JOB SITE AND BE FAMILIAR WITH LANDLORDS REQUIREMENTS, NO 0 WHA ALLOWANCE WILL BE MADE FOR EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOB SITE ' AND/OR FAILURE TO PREDETERMINE ALL CONDITIONS IMPOSED BY THE LANDLORD OR OTHER AUTHORITIES. I ''s . 2. ALL ROOF CUTTING, PATCHING AND FLASHING REQUIRED TO INSTALL THE PLUMBING SYSTEMS SHALL BE Ali r ti�,'\„, 3/4" BY A LANDLORD APPROVED ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. COORDINATE 1 s ga7 WH • ROOF PENETRATIONS WITH LANDLORD AND GENERAL CONTRACTOR. 1 I 3. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL STRUCTURAL STEEL REQUIRED 3/4" "' % TO SUPPORT ANY MECHANICAL EQUIPMENT. THIS CONTRACTOR SHALL COORDINATE LOCATIONS AND 1 2" ,` `` REQUIREMENTS WITH THE GENERAL CONTRACTOR AND LANDLORD PRIOR TO BID. 1 2" / ~..2%.„„ / , . 4. PIPING SHALL NOT BE LOCATED OVER THE TOP OF ANY ELECTRICAL PANELS OR EQUIPMENT. 0 a J J 1, TP 5. PLUMBING CONTRACTOR SHALL COORDINATE FLOOR, WALL AND ROOF PENETRATIONS, ETC. WITH ' GENERAL TRADES. PLUMBING CONTRACTOR IS TO PROVIDE AND INSTALL FIRE—RATED PIPE SLEEVES S220 /'r/ AND SEALS ON ALL EXISTING OR NEW PIPING THAT PENETRATES A FIRE—RATED PARTITION. MS 1 DU 3/4",• WASHINGTON SQUARE 3 I / • I 6. THE PLUMBING CONTRACTOR SHALL COORDINATE AND PROVIDE ACCESS DOORS IN HARD CEILINGS FOR ,/ r 1 1/2" ALL EQUIPMENT WHICH REQUIRES ACCESS. aW" S� O •"�.'''- 1/2" 7. PLUMBING CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT AND PIPING, NOT BEING USED OR SHOWN SITE HOS rrLAV TO REMAIN, IS FULLY REMOVED AND NOT ABANDONED. REFER TO SPECIFICATIONS FOR ADDITIONAL OR +�r� 1/2" ,/' INFORMATION. ar `•/ ' •IA -�' •/ r 2 DURING CONSTRUCTION SHALL BE ° 1/2 3 (E) " �/ j ,/2" 8. ANY EXISTING WALL/FLOOR OR CEILING SURFACE THAT IS DAMAGED DU G CO " , 0 : b%4 ■ # > 3/4/ 0 REPAIRED TO MATCH NEW AND/OR EXISTING CONDITIONS. 1/2" SINK a` ' 3/4" 1/2" PLUMBING CODED NOTES fii1 1,4 '•"� ` 3/4" 2 O CONNECT NEW SANITARY LINE INTO THE LANDLORD'S EXISTING SANITARY SERVICE AS SHOWN. FIELD %. V / I " WC VERIFY EXACT LOCATION OF LANDLORD'S MAIN PRIOR TO BIDDING. INSTALL CLEAN OUT AT , .///#' 1/2"1 :1/2 2 CONNECTION TO LANDLORD'S MAIN. REFER TO STACK DIAGRAM AND PLUMBING SPECIFICATIONS FOR ..1 ] FURTHER INFORMATION. FIELD VERIFY EXACT LOCATION OF SANITARY CONNECTION PRIOR TO BID. 0Tw 02 EXTEND NEW VENT AND CONNECT TO LANDLORD VENT MAIN. REFER TO STACK DIAGRAM AND LAV PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. 2 f .v @:: CONNECT NEW COLD WATER PIPE INTO THE EXISTING COLD WATER TAP. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. FIELD VERIFY EXACT LOCATION OF LANDLORD'S DOMESTIC COLD WATER PIPE PRIOR TO BID. NTS ® FURNISH AND INSTALL WATER HAMMER ARRESTERS IN THE DOMESTIC COLD AND HOT WATER PIPING f t✓ ` 5 O ARRESTERS TO LOCATED IN AN STACK _ AS SHOWN ON THE WATER RISER DIAGRAM. WATER HAMMER aRRES ERS OBE LOC ED I, ‘ ACCESSIBLE LOCATION. UNITS AS MANUFACTURED BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE k '- U `` ' ACCEPTABLE. . r D ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER FOR FURTHER INFORMATION. TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS OR UR ER 4 06 INSTALL 1/2" WATER PIPE FROM TRAP PRIMER DOWN IN WALL UNDER FLOOR TO FLOOR DRAIN. TRAP PRIMER TO BE LOCATED IN AN ACCESSIBLE LOCATION. 0 1/2" CW TO REFRIGERATOR ICE MAKER. PLUMBING CONTRACTOR TO MAKE ALL FINAL CONNECTIONS. 0 THE LANDLORD'S PLUMBING CONTRACTOR SHALL INSTALL CONDENSATE DRAINS FROM ALL NEW RTUS AS SHOWN ON PLANS. MINIMUM DRAIN SIZE TO BE 3/4" OR AS SPECIFIED ON PLANS. DRAINS SHALL BE EXTENDED (AT A SLOPE OF 1" PER 8' ) TO THE SPLASH BLOCK AS INDICATED ON PLANS. ROOFTOP/EXTERIOR PIPING TO SPLASH BLOCK SHALL BE U.V. RESISTANT PVC H B K PIPING. PVC JOINTS SHALL BE CHEMICALLY WELDED. 0 TENANT'S PLUMBING CONTRACTOR TO INSTALL 3/4" CONDENSATE PIPING FROM DUCTLESS AIR CONCONSULTANTS, LTD CONDITIONING UNIT AND EXTEND TO LANDLORD'S MOP SINK LOCATED AT COLUMN LINES "15" AND "D". Mechanical Cp & Elric®I Design Services 171 Charring Cross Drive S. r , Suite 1B Westerville, Ohio 43081 ,---) 614,882.1 i 99 FAX 614,882,1857 0 Drawings and written material appearing herein constitute original 1 I it ELECTRMCAL and unpublished work of the Architect and may not be duplicated, #- 11-1 2 used or disclosed without written consent of the Architect --, I / " r' M8H ARCHITECT 2010 00' , 1 H l . I . MS i _.' / 147,1"71 ONOC WW !� 3 . ..► No. Dale Issue 3" Allik 1 NS TAL L IC ON 05/28/10 100% SET FCO r► PLATFORM OVER 6 �� `�► " MOP SINK NITOR \ 0,,,Iik 1-1/2 LOSET 05/28/10 VT PACKAGE ... < /��" " � — " 07/02/10 100% COMPLETE SET 3"(E) 3 1 1/2 l —1--d\ 07/28/10 LANDLORD SET FCO 08/13/10 PERMIT/BID SET ■ 'I PLUMBING SYMBOLS 1-1/2" 1 L FTI THERMOMETER •�� �', 1 4"(E) r .� — — — -- DOMESTIC WATER PIPE L._ TOILET I` " ■■ 2" i- \ t ROOM 1-1/2" `� �' I I — — 11 = DOMESTIC HOT WATER 110'F 9 PRESSURE GAGE ■i ■ i - 4 0 0 DO ES C •'T 21'1 FD —0 * INLINE PUMP ■ ,, 1 1 3" LAV MEETING/SECURITY — — 140 DOMESTIC HOT WATER 140'F SINK — ,r 2»( ( 1 .r .�- WC �;''''�'''11���-� • D3FPD BACK FLOW PREV, 2 ■, ` .i 1 1 " FD I --HWR DOMESTIC HOT WATER RETURN ____-_- v " 1 ( 4 4" 2 Ø(Tw) 5 i P & T RELIEF VALVE 0 \ I SPRINKLER PIPE " 1-1/2'2---. 4" 4" WC All . . OT ") ACCESS DOOR — • G GAS PIPE 1 1/2 I " 4 � �" 3" 3 WC J 72 4 _ , '-1 FD -cam • SANITARY PIPE CI< COMBINATION BALANCE WCO I FD 6 ray I - --- --- - - - SANITARY VENT PIPE /SHUT—OFF 2 _ I LOUNGE e.` S VE a . -I =�; • da GATE VALVE ii„ I " LAV 0 , SINK 1 , . ....L_ mil y )` '•) --STM —�— STORM PIPE a • prQ GLOBE VALVE lism 0(TYP) --OF STORM OVER FLOW PIPE I II BUTTERFLY VALVE 1 .� �' TOILET _'� I L L IIQ--3 DRAIN VALVE Project No. 44122/10038 I -� 0-4 PIPE — UP I WCO ICI CHECK VALVE O C� Score AS NOTED a J PIPE — DOWN III UNION L :'-' GO DrovnB WDB/KH I DESIGNATION, REFER TO fxt PLUMBING FIXTURE Drowsily: KITCHEN EQUIPMENT N CONNECTION SCHEDULE ON SHEET P2. 1 . fxt PLUMBING FIXTURE .. x FIXTURE UNITS A2010 \>too u r�� (E) 111111111 Q FIXTURE UNITS . (R) RELOCATE Droving No. ( -- PARTIAL PLUMBING PLAN, P03.1- DETAIL MARK NOTES AND VERIFY ALL CONDITIONS IN FIELD PRIOR TO BIDS. , ISOMETRICS I g NTS 1/410-0' NTS i STACK .. 6 PARTIAL PLUMBING PLAN 4 PLUMBING NOTES _ M 3.1 c PLUMBING FIXTURE SCHEDULE FIXTURE FAUCET CONNECTIONS MARK FIXTURE DESCRIPTION MANUFATURE MANUFATURE REMARKS & MODEL & MODEL SAN TRAP VENT CW MN NUMBER NUMBER 110' •WATER CLOSET, FLOOR MOUNTED, AMERICAN STANDARD — A WC TANK TYPE, ADA COMPLIANT, L6 #2998.012 4" INT. 2" 1/2" --- 0000 GPF PRESSURE ASSISTED FLUSH WITH ELONGATED VITREOUS CHINA BOWL. COLOR — WHITE LAVATORY 20"X18" WALL HUNG AMERICAN STANDARD MOEN #8882 US220 LAV VITREOUS CHINA, ADA #0355.012 METE7GFT IN SELF 1-1/2" 1-1/2" 1-1/2" 1/2" 1/2" 0000®® COMPL I ANT, COLOR — WHITE , WASHINGTON SQUARE AMERICAN STANDARD #2411 .015 GRID EN. Washington Square DRAIN. SUITE H08 SINK COUNTER TOP SINK, 18 GA. JUST CHICAGO #2300-8 eee PORTLAND, OR 97223 STAINLESS STEEL , SELF #SWB-2125—A—GR—L W/E2605-5 1-1/2" 1-1/2" 1-1/2" 1/2" 1/2" ( RED RIMMING AERATOR & JUST #J-35 CRUMB CUP. MS MOP SINK, MOLDED STONE FIAT #MSB-2424 FIAT #830—AA, FLOOR MOUNTED, 24X24, 10" WITH INTEGRAL 3" 3" 1-1/2" 1/2" 1/2" ee® HIGH. STOPS AND VACUUM BREAKER. FLOOR DRAIN ZURN #ZN-415 __ FD 3" 3" 1-1/2" -- -- GOO , ,. . f. r t t d ..... NTS � � r 3 , , SCHEDULE NOTES: O ALTERNATE MANUFACTURERS — AMERICAN STANDARD, KOHLER OR CRANE. a FURNISH WITH OPEN FRONT COMMERCIAL GRADE WHITE SEAT, 8 INSULATE P—TRAP AND SUPPLY LINES PER ADA, SEE SPECS, FOR ADDITIONAL INFORMATION. 2 FURNISH & INSTALL STOPS. 0 FURNISH WITH TRAP PRIMER & DEEP SEAL TRAP. @:: FURNISH & INSTALL "P" TRAP. ('i0 ALTERNATE MANUFACTURERS — WADE, JR SMITH. OR JOSAM. ::D 11 ALTERNATE MANUFACTURERS — STERN—WILLIAMS, MUSTEE. .. H B K SEE ARCHITECTURAL PLANS FOR INSTALLATION HIEGHT. VENTED 12 FURNISH W/#832—AA HOSE & BRACKET, 889—CC MOP HANGER, RTU PERFORATED CONSUL ANTS LTD O FURNISH & INSTALL HANGERS / CARRIER FOR WALL INSTALLATION, E-77—AA V I NYL BUMPER GUARD, 833—AA S I L I CONE SEALANT SLOPE R CAP Mechanical do Electrical Design Services N 13 ALTERNATE MANUFACTURERS — ELKAY OR MOEN, CI) PROVIDE WATER CLOSET TRIP LEVER ON THE OPEN SIDE OF WATER CLOSET PER ADA REQUIREMENTS. 14 ALTERNATE MANUFACTURERS — HALSEY TAYLOR, OASIS, RTU CONDENSATE DRAIN 171 Charring Cross Drive S. co TO DISCHARGE TO Suite 1B ''`'' M SPLASH BLOCK Westerville, Ohio 43081 CONNECT TO 614.882.1199 ROOFTOP UNIT • FAX 614,882,1857 12" X12" • I( .....1 SPLASH ) \ __,'____ ‘.......................--." BLOCK Drawings and written materiel appearing herein constitute original and unpublished work of'the Architect and may not be duplicated, ROOF used or disclosed without written consent of the Architect PLUMBING EQUIPMENT SCHEDULE ®N B H A R C H I T E C T - 2 0 1 0 OAOC WH WATER HEATER — A.O. SMITH #DEL-10 ELECTRIC WATER HEATER. 10 No. Date Issue GALLON, 10 GPH RECOVERY AT 100'F RISE, 2500 KW, 208V. 1 0, 05/28/10 100% SET MANUFACTURERS: LOCHINVAR, RUUD OR APPROVED EQUAL. 05/28/10 VT PACKAGE FCO FLOOR CLEAN OUT — ZURN #Z-1400, CAST IRON BODY WITH GAS 07/02/10 1007 COMPLETE SET AND WATER TIGHT ABS TAPERED THREAD PLUG AND ROUND SCOR I ATED TOP ADJUSTABLE TO F I N I SHED FLOOR. FURNISH 07/28/10 LANDLORD SET TOP SUITABLE FOR FINISHED FLOOR. SEE ARCHITECTURAL CONDENSATE DRAIN DETAIL NTS r� 08/13/10 PERMIT/BID SET PLANS FOR FLOOR FINISH, MANUFACTURERS; WADE , L SMITH OR APPROVED EQUAL . WCO WALL CLEAN OUT — CAST IRON CLEAN OUT TEE WITH BRONZE THREADED CLEAN OUT PLUG. PLUG TO BE GAS AND WATER TIGHT. WALL ACCESS PANEL — ZURN #ZANB-1460-9, 9" X 9" ....—THERMOSTATIC MIXING VALVE WALL ACCESS PANEL AND FRAME ; SMOOTH NICKEL BRONZE LEONARD MODEL #220. SET SECURING LUGS. ACCEPTABLE ALTERNATES, WADE OR SMITH. VALVE FOR 11O'F HW TEMPERATURE VACUUM BREAKER BY P.C. ""` ? HW 0'411 .��„..._ INSULATE ALL PIPING CO CLEAN OUT (ABOVE CEILING OR EXPOSED I N OPEN CEILINGS) — GATE/BALL VALVE �'' 0 IN ACCORDANCE WITH CAST IRON CLEAN OUT (TEE) WITH BRONZE THREADED CLEAN OUT BY P.C, (TYP.) —_A SPECIFICATIONS, PLUG. PLUG TO BE GAS AND WATER TIGHT. c�—CW F o ----UNION BY P,C. (TYP,) TP TRAP PRIMER— PRECISION PLUMBING PRODUCTS #P2-500 WITH 3/4" r 3/4,, .-3/4" T & P RELIEF ADJUSTABLE FLOW RATE, INTEGRAL VACUUM BREAKER AND HANGERS / IT _ VALVE BY P.C. INTEGRAL BACKFLOW PREVENTER MOUNT ABOVE CEILING IN ACCESSIBLE LOCATION. NOTE : CONSULT PLUMBING INSPECTOR INSTALLED / - WATER HEATER SEE PRIOR TO INSTALLING TRAP PRIMER, EQUAL BY SIOUX CHIEF EACH SIDE OF PLUMBING FIXTURE OR ZURN, EXP. TANK SCHEDULE FOR FOR SUPPORT 1 ADDITIONAL INFO.________,,)e._}DU TRAP PRIMER D I STR I BUT I ON UNIT—PRECISION PLUMBING AMTROL ST-5 PRODUCTS #DU-2. PROVIDE WITH SS-8 SUPPLY TUBE . THERMAL ?' -- 2" WIDE, 20 GA. SHEET EQUAL BY SIOUX CHIEF OR ZURN. EXPANSION METAL BAND, SECURE ' ABSORBER TO WALL FOR SEISMIC 3/4" RUN FULL SIZE ' BRACING WHERE Project 110. 44122/10038 REQUIRED BY CODE. TO MOP SINK, (BY P.C.) y III Scale AS NOTED DRAIN VALVE BY P.C. ' "....„�u GALV, DRIP PAN J1N BY P.C. W/R-10 INSULATION 6" j •sBy: WDB/KH i SHELF ABOVE MOP SINK, y o . 1" DRAIN a SHELF & BRACKETS BY SEPARATE GENERAL CONTRACTOR DRAINS SINK. J:\1010,lobs\10038\uS220M32.d.g it Or0 o•ing No. _ 8 N PLUMBING DETAILS AND i . SCHEDULES g .1 PLUMBING SCHEDULES NTS NTS i _ 4 WATER HEATER DETAIL _ 1 M3 . 2 - 0 0 G • DD BB • AA • 0 • 0 1 1 I 1 1 1 1 1 7.2g2,--..ai I I I I I T . I I I US220 I I I I I I 1 _ WASHINGTON SQ1JRE •■■■■ w■••■••■••■:01 INIMIle=111■-N.Mt ....... • :it . ,._, _�,, a ._u.. _ ,_ DISPLAY I I I I I I I ( - I '' I I OR 97228 WINDOW #1 I1 4 4 O I O O ^LL I'.`:� f•:Ft �`< $i iii ,_�,, .w.: ;; EVERYDAY C�L 4>1 I I II 1 EVERYDAY I I I I , / I ci ���ww - ■l-- -- -- — II --- —• — �!!�il!!__ Ina ill _ --- — — — - ! II _ uur.�i°i�>t�.•i I I 1 `ter ;-. ;:: I I 11E4 CI! , „ , _ �I _� ■'� ID /, „ \ / , I � I I y, ,II a ' ILl . . . e ii, 0 0 . o 0 0 ., • E u • , E (y'iv RED 1 1 ....� SALES I 1,� ❑ MACHINE ANA , ROOM r. 0 0�. ` / e d t 1 • , l CO 0 1 . I WOMENS I ,_ ._. ._. .�..�, . �, I 1� :; \ / l } SALES • 0 o \ /� 0 r/2",IF t ._ A.wPr I O 0 0 0 O 0 \ c0 0 O ,: j _ rah. iK�*'. : i!! 1�..' }-r•i t :: I1• I I EVERYDAY i / Ell : :; I . ' I\-- -- _ _._ _. MALL COMMON /4 „ ,T.:',' '' .>t t : I 0 ,,,, I 4 - 4 ,... O N f1{+/MM�/��11��, ' 4,:e ail a ,. ! r. .d EVE it , . I t1 S ki *) r.,'D /o - - .., ( O 0 O i , :: ` „, 1 1 I I .� �yMOMEN8 r,i,s,. I ,l 1 i I �/ BALES !M..�1 : / , I O ,,,,,:,,,,,,11.., ,'1 1 �1� I -..r —. .______. ____- --�--- ” : 1 it'i:_��. ■,,� =-- .. lid .. — _ lji _ � ��I — — — — t— 111111.1111110MMOiiiiiiiiimida— ---- — -- — — ill _ .__ .._ El ' . ' .I fit Rs, Rz 3-e , :'tF"'. 1 la) ; II / \ x I I I I I I - . 1 U womml =HI 0 0 0 0 0 ,• are �=, ra ;r:� ':5 ,, �� ... 0 0 —,———,...._., II 0 0 : \ I I 11:Ell • I I LO.QQ ..w, I iii �rrnNG II •1 O O r t; O° o 0 0 0 0IL o : 1 H ii K a., t, , I I I ,, I ma J ' , ' DIV:ACc + II II ♦ t II A,�I�p�/ UNDERLLt � ' LO.G.Q .. 111 SUL AS�'TS 1 I► I I � � ci S ' 1 ( I MCONoi dt Electrical Design Services �HSPLAY O O O I WINDOW #2 I 0 I I i11 .�,# a I I I � ' 1 � Y I` ill 171 Charrin Cross Drive Sill ��t e CC �r. cr� T .,- ' � Weisterville� Ohio 43081 1 1 0 - 0 _; 0 0 0 k O 0 C) ._ O ° I, r ,' FAX 86141882 U I . ct 1857 I I iI I = 4' i a _. -- I >1 r L � I 1 ► - - go•.:� — .4 — — —_ — — — —■— — — ,... — — .:: — :.._......._....I — — — 36 I I I I I I I I Drawings and written material appearing herein constitute original and unpublished work of the Architect and coal not be duplicated, ADJACENT used or disclosed without written consent of the Architect TENANT-N.LC• c@MMBH ARCHITECT - 2010 SPRINKLER CONTRACTOR TO NiiiiiiiinaMilliii11111 SUBMIT SHOP DRAWING FOR °AOC H&M APPROVAL PRIOR TO No. Dote Issue SPRINKLER GENERAL NOTES FABRICATION. : ::/10 100 SET VT PACKAGE 1 THE CONTRACTOR FOR THIS DIVISION OF WORK I S REQU I RED TO READ 07/02/10 100% COMPLETE SET THE SPEC I F I CATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF 07/28/10 LANDLORD SET WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK• I T 08/13/10 PERMIT/BID SET IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. FIRE SPRINKLER HEAD SYMBOLS 2 FIRE PROTECTION PLANS, SPRINKLER DRAWINGS, MUST BE ENGINEERED AND WET SIGNED BY A LANDLORD APPROVED, LICENSED REGISTERED • , FIRE PROTECTION CONTRACTOR I N THE LOCAL JURISDICTION. FINAL S Y M B O L D E S C R I P T I O N INSTALLATION MUST COMPLY WITH NFPA 13, TENANT'S INSURANCE !° COMPANY, STATE AND LOCAL AUTHORITIES HAVING JURISDICTION. 3. SPRINKLER HEAD LAYOUT IS A SUGGESTED LAYOUT. SPRINKLER HEADS • UPRIGHT SPRINKLER HEAD ARE TO BE ALIGNED WITH LIGHTING PATTERN AS SHOWN. COORDINATE SPRINKLER HEAD LAYOUT AND PIPE ROUTING WITH ARCHITECTURAL C1 SEMI—RECESSED PENDENT PLANS, STRUCTURAL PLANS, MECHANICAL CONTRACTOR, PLUMBING SPRINKLER HEAD CONTRACTOR, ELECTRICAL CONTRACTOR AND TENANT'S PROJECT MANAGER. FIRE PROTECTION CONTRACTOR SHALL INCLUDE IN THE BID 0 CONCEALED SPRINKLER HEAD AND BE RESPONSIBLE FOR EXACT QUANTITY OF SPRINKLER HEADS REQUIRED FOR COVERAGE AND FINAL APPROVAL . PENDANT SPRINKLER HEAD 4. SPRINKLER CONTRACTOR SHALL RAISE OR RELOCATE ALL SPRINKLER BRANCH 6" PIPING THAT INTERFERES WITH DUCTWORK INSTALLATION AND CEILING 10'— I CEILING ELEVATION HEIGHTS. COORDINATE ALL WORK WITH LANDLORD AND HVAC/GENERAL , CONTRACTOR AND INCLUDE ALL COSTS IN BID. 5. NOTE: SALES AREA CEILING COLORS VARY. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR ACTUAL CEILING COLORS AND FURNISH SPRINKLER HEAD COVERS WITH FACTORY FINISH TO MATCH. SUBMIT COLOR SAMPLES TO ARCHITECT FOR APPROVAL• Project No. 44122/10038 SPRINKLER CODED NOTES stole AS NOTED Iiiiiiiii </ EXISTING VERTICAL DUCTS TO REMAIN. COORDINATE EXACT LOCATION IN FIELD, 2 INSTALL A WATER CURTAIN AROUND ESCALATOR OPENING PER NFPA 13 AS 0 r o o B y: WDB/KH REQUIRED BY CODE. OINSTALL SPRINKLER HEADS BELOW ESCALATORS PER NFPA 13, S` 4 INSTALL SPRINKLER HEADS IN ELEVATOR SHAFT PER NFPA 13, N .1N2010 Ms\$00 t 2Owto 7 K INSTALL SPRINKLER HEADS IN STAIRS PER NFPA 13. D r o v i n g No. 0 - €'i ED SPRINKLER HEAD PLAN VERIFY ALL CONDITIONS IN FIELD PRIOR TO BIDS. FIRST LEVEL virer-o.SPRINKLER HEAD PLAN - FIRST LEVEL _ M4.la ... - . 0H ,i (ilAi„ Ca • 4 • 0 0 '� 1u7 a• s NM:REA . ::s. _..:.- - r ti DD BB AA 220„.. . ' : , , , ' '' _. : WASHINGTON SQUARE ,. .. ROOM �► ....._ , ...„,,,:i, , 9686 S.W. 8�aueirrr HARDWARE. \/ SATE HOB i —I 0 /� • TL OR 97223 I 1 I I ADMIN 1 ROOM --- O 0 1 _ I a I I I TENANT-w.C. I I I I ha 0 • . ., . , . .. . , ”. . :, „ •., . . , .,.„ „ , . . , . ., .. ,•• „ .. .„ „ ,_____, M M Ni M M 1 h. ,.....,:. ! .,,.1 - Go . . ..... . . . _................11•1■M=IMF IMMIIIr IMMIIIIIMMIr.... ri MTV - - I I I 1 M 1 O �J O O I O O o O of� � M r .0_: 0 MENS H& I 1 / ,�4. t �IEN8 LQ�G. I:1 1 I .. . . 7 i,---...„—. ',.---..„:.,,„..,„----i,,:—,-,,,,..---,z„! — . E �s r ----- alst--7: . ''---; 0 fl. :.:01401. :,': al , . M a . =AD II O O O O O O O 7 Ori S =: ELEVATOR ?`Yt _ I _____I;FI-Li . •0 , 0 MENS SALE � / r �� � ,� i.,, ABEA 1 / wry' r'! c 14' t'1 J-. 111 111111111MIPEM. (to 0 0 . , , , „ . .•• : . , . kg. 6 \ / 0 0 0 0 o ...a.n. ._..n._ .,.n. a..... .. : O a 0 0 0 0 O 0 O O m,, ;.Y .-_; I N 4_. YS • P \ 0 / TA II p SALES AREA f ' 1 O IC. ri t'� iy4�' t n r,.JT ` t ' ;vs.t . :: ,�..Y .� 0 <._ 0 0 o o t a o / o r, . , IC , , o 0 0 o o ■ � / J . . � O 1 - .e• ..A p l p I O 1 . . .: :.: MO , ., PE TC�. :• ii _ VN ' AREA Nl a I I 1 0 0 0 O 0 0 ., Mechanical do Erectr car Design Services ;; CONSULTANTS, LfiD► t r;`{ �' i esign vi, ,: Izzzza _ ___ _____zuzmzazzlz,_. . , : :. . ,. . . . . : , 0 0 0 , � CJ '\ .: .. —.1 --- \ 4 ,• _ _. 1 — __. ._ --- -- N. g� / 1 ' Cross Drive S. 171 Charring r r �. �., (:� o O 0 a a o is 0 p; Suite 18 0 0 0 / ;,, Westerville, Ohio 430$1 ,► 0 0 0 I'll .. IE8 y� I u \ 614.882.1199 FAX 614,882,1857 c t r PIA UNDERW. + ; 11: 01 0 I 0 I 0 0 0 0 0 0 0 0 0 0 0 0 0 0 - - :._ jI r r herein t € / 0 ow'ngs and written malarial appearing here' constitute original � 1 and unpublished work,of the Architect oad may not b:ed upliSLAREA � , ® £. used or dsclosed withoten cons Architect I I HIV� I I ' . BLUE +a o _ o 0 0 p,MEN8 a 1 H►I � x.0 o I o o d o o R I 1 NDEW. '' d 0� UNDERW. + I♦ �� =-� ,` No. Dole Issue I�� - a „P -1 1 I . I IL , ( AM I `� ® r ' J. o /28/t o 100 o sET 511,I.-....r. ko CY r-? Y:. '4 t,:? !•a 5 V♦ ,I o a o O I►.� ♦ 0 y41. STAIRS 05/28/10 VT PACKAGE o _: o 0 0 0 ,.) 0 , o N 1.z F.I`� 1 I L _: . _ _: _1 I I a7/o2/t o o sET T T T T __:_ T T _. .. L 1009' COMPLETE►..�1►��1►�1►.►�1►.��/►.'►11►�►�t►w�►�� S_ _ ►.!/►..►�I►��►..�I►��►��►��I►��I►mod w►�moo i.■■ iii751 1` » _ __- _ i __ — — 0 -- — e -- — — — _.._ _. 07/28/10 LANDLORD SET 08/13/10 PERMIT/BID SET ADJACENT TENANT-N.I.Q SPRINKLER CONTRACTOR TO SUBMIT SHOP DRAWING FOR H&M APPROVAL PRIOR TO FABRICATION. FIRE SPRINKLER HEAD SYMBOLS mi., ,:.. --..—- .: SYMBOL DESCRIPTION Project No. 44122/10038 • • UPRIGHT SPRINKLER HEAD . SEMI–RECESSED PENDENT :111;;;;;;;I: AS NOTED SPRINKLER HEAD SEE SHEET M4�.1a FOR 0 CONCEALED SPRINKLER HEAD WDB/KH SPRINKLER GENERAL NOTES AND SPRINKLER CODED •.• PENDANT SPRINKLER HEAD h NOTES. 10'-6" I CEILING ELEVATION N A201.0 JobA10038VS220M41bdeg , Z. o Droving No. r Mir SPRINKLER HEAD PLAN ' i VERIFY ALL CONDITIONS IN FIELD PRIOR TO MERZZANINE LEVEL i , r BIDS. 1 SPRINKLER HEAD PLAN - MEZZANINE LEVEL 1 M 4.1 b _ DIVISION 15 - MECHANICAL ( NOT APPLICABLE ) 2. SANITARY PIPING 4. RELOCATION OF EXISTING MAINS, LATERALS, BRANCHES AND RISERS TO FACILITATE STORE DESIGN SECTION 15000 CRITERIA MUST BE INCLUDED IN BID PROPOSAL. CONFIRM REQUIREMENTS WITH GENERAL CONTRACTOR BASIC MECHANICAL REQUIREMENTS THIS CONTRACTOR IS To ' .: . IS BID ALL NECESSA' - WIRED TO KEEP THE A. WASTE, DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON SOIL PIPE. VENT AND TENANT'S PROJECT MANAGER PRIOR TO BID. A, NOTE OPERATING PHASE OF THE STORE'S HVAC No��. ...1m" SPRINKLER SERVICE IN OPERATION. IF PIPING ABOVE FLOOR 2 OR SMALLER MAY BE GALVANIZED STEEL. ALTERNATE PIPING APPLICABLE CONTRACTO• . 1 'I E IN WRITING WITH ' "o CT MANAGER AND THE MATERIALS ARE ACCEPTABLE AS A SUBSTITUTION WHEN THEIR USE IS PERMITTED BY THE B. SHOP DRAWINGS 1 . DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY LAND •►' ' 'RIOR TO ANY SHUT DOWN OF THE HVAC, PLUMBING OR FI• -=i _ •► LANDLORD, LOCAL CODES AND BUILDING DEPARTMENT OFFICIALS AND DOES NOT AFFECT OTHER CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS STEMS. TRADES. SUBSTITUTIONS MUST BE LISTED AND QUALIFIED IN BID. 1 , THIS FIRE PROTECTION CONTRACTOR SHALL PREPARE DETAILED SHOP DRAWINGS AND CALCULATIONS OF DIVISION 15. B. INSULATE ALL HORIZONTAL RUNS OF PIPING LOCATED IN CEILING SPACES OF TENANTS IN FOR HIS WORK. SUBMIT SIX (6) COPIES TO GENERAL CONTRACTOR FOR APPROVAL. J. DEMOLITION SPACES BELOW, WHEN APPLICABLE. INSULATION TO BE AS SPECIFIED FOR WATER PIPING. 2 FIRE PROTECTION PLANS, SPRINKLER DRAWINGS, MUST BE ENGINEERED AND WET SIGNED BY A 2. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND LANDLORD APPROVED LICENSED REGISTERED FIRE PROTECTION CONTRACTOR IN THE LOCAL REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF 1 . THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING 3. POTABLE WATER PIPING SHALL BE AS FOLLOWS: • WORK AND THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE JURISDICTION. FINAL INSTALLATION MUST COMPLY WITH NFPA 13, TENANT'S INSURANCE COMPANY, HIS WORK AND THE WORK OF HIS SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. A. BELOW GRADE: TYPE 'K' , ANNEALED TYPE TEMPERED COPPER TUBE FOR PIPE SIZES 2 STATE AND LOCAL AUTHORITIES HAVING JURISDICTION. CONTRACTORS RESPONSIBILITY TO PROVIDE HIS SUBCONTRACTORS WITH A COMPLETE SET OF BID INCHES AND SMALLER. BRAZE ALL JOINTS. DOCUMENTS. 2. EACH CONTRACTOR SHALL VERIFY SCOPE OF WORK WITH GENERAL CONTRACTOR AND WILL BE HELD B. ALL OTHER: TYPE 'L' DRAWN COPPER TUBE WITH WROUGHT CAPPER FITTINGS AND 3. THIS FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SUBMITTING COORDINATED DRAWINGS, RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING FIRE PROTECTION, PLUMBING FIXTURES, 95-5 TIN-ANTIMONY SOLDER HYDRAULIC CALCULATIONS, HEAD TYPES AND COLORS TO ALL AUTHORITIES HAVING JURISDICTION 3. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF HIS WORK FOR APPROVAL. NO WORK SHALL BEGIN UNTIL ALL APPROVALS HAVE BEEN RECEIVED. US220 AND THE WORK OF HIS SUBCONTRACTORS WORK TO COMPLY WITH THE SCHEDULE AND THE PROJECT PIPING, HVAC UNITS, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT TO BE REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST 4. CONDENSATE PIPING COMPLETION DATE. 4. A COPY OF THE LETTER OF APPROVAL FROM THE LANDLORD'S INSURANCE RATING BUREAU SHALL BE WASHINGTON SQUARE VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, DUCTWORK, AND ' EQUIPMENT PRIOR TO REMOVAL. ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED. ALL A. INTERIOR CONDENSATE PIPING SHALL BE TYPE "L" DRAWN COPPER TUBE WITH 95-5 TIN- FORWARDED TO THE LANDLORD'S AGENT AND TO TENANT'S PROJECT MANAGER. 4, THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE ANTIMONY SOLDERED JOINTS AND WROUGHT COPPER FITTINGS WITH DIELECTRIC SEPARATION �� Solaro AFFECTING THE WORK, ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY REMOVED AND ROOF/WALL/FLOOR PATCHED/REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING BETWEEN DISSIMILAR METALS. DRAIN SHALL TERMINATE AT A CODE APPROVED LOCATION. C. EQUIPMENT AND INSTALLATION SUITE H08 PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE ALTERNATE PIPING MATERIALS ARE ACCEPTABLE AS A SUBSTITUTION WHEN THEIR USE IS SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY PERMITTED BY THE LANDLORD, LOCAL CODES AND BUILDING DEPARTMENT OFFICIALS AND DOES 1 � SPRINKLER HEADS: PORTLAND. OR 97228 MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED NOT AFFECT OTHER TRADES. SUBSTITUTIONS MUST BE LISTED AND QUALIFIED IN BID. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN A. ALL SPRINKLER HEADS SHALL BE NEW (EXISTING HEADS IN EXISTING TENANT'S STORES ARE CLAM RED PIPING AND/OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF NOT TO BE REPLACED UNLESS NOTED OTHERWISE), U L F M LISTED AND APPROVED PERFORMANCE OF WORK. + • DEMOLITION PRIOR TO BID AND INCLUDE IN BID PROPOSAL. B. EXTERIOR CONDENSATE PIPING SHALL BE SCHEDULE 40 U.V. RESISTANT PVC PIPING. PVC AUTOMATIC SPRAY TYPE AS MANUFACTURED BY CENTRAL SPRINKLER CO. , GLOBE, GRINNELL, B. GENERAL REQUIREMENTS JOINTS SHALL BE SLIP FIT. DRAIN SHALL TERMINATE AT A CODE APPROVED LOCATION. RELIABLE, STAR, OR VIKING. K. CUTTING AND PATCHING M A M NT RVI 5. PIPING OF DISSIMILAR METALS MUST BE DI-ELECTRICALLY SEPARATED. B. DRAWINGSNOREREQUIREDSBYLLOCALRCODESFOR 165 DEGREE F UNLESS INDICATED OTHERWISE ON 1 , THIS CONTRACTOR SHALL PROVIDE ALL LABOR, ATERI LS, EQUIP E , SE CEO, TOOLS, 1 . THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING AS REQUIRED FOR THE INSTALLATION C. ALL SALES FLOORS HEADS ARE TO HAVE BE FACTORY APPLIED COLOR FINISH. VERIFY HEAD TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE MECHANICAL OF THE WORK UNDER THIS SPECIFICATION. NO CUTTING OF THE STRUCTURE SHALL BE PERMITTED 6. GENERALLY, SANITARY AND POTABLE WATER TAPS WILL BE PROVIDED BY THE LANDLORD. FIELD + SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY WITHOUT WRITTEN APPROVAL OF THE LANDLORD, LANDLORD'S STRUCTURAL ENGINEER OR ARCHITECT. VERIFY EXACT CONNECTION POINTS PRIOR TO SUBMITTING BID AND NOTIFY TENANT'S PROJECT TYPES AND COLORS WITH TENANT S S PROJECT MANAGER AND SUBMIT WITH SPRINKLER JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR TENANT MANAGER IF CONDITIONS ARE NOT AS SHOWN ON THE PLANS OR AS STATED IN THE SPECIFICATIONS. DRAWINGS FOR PERMIT, SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE SPRINKLER HEAD TYPES SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE: INSTALLATION WITH THE LANDLORD AND THE TENANT'S PROJECT MANAGER, AS REQUIRED. 2. PATCHING SHALL BE OF THE SAME WORKMANSHIP, MATERIAL AND FINISH AND SHALL MATCH CONTRACTOR MUST VERIFY THE OPERABILITY OF ENTIRE SYSTEM PRIOR TO TIE IN AS FOLLOWS: 1 . IN SALES AREA, DRYWALL OR LAY-IN CEILINGS: SPRINKLER HEADS ARE TO BE ACCURATELY ALL SURROUNDING CONSTRUCTION IN A MANNER SATISFACTORY TO THE LANDLORD, A. SNAKE SANITARY FOR A DISTANCE OF 100 FEET AND REPORT ANY BLOCKAGE. CONCEALED TYPE, COVER PLATE TO HAVE FACTORY APPLIED COLOR FINISH.2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL ARCHITECT AND TENANT'S PROJECT MANAGER. B. TEST WATER PRESSURE TO INSURE MINIMUM PSI MATCHES MOST DEMANDING EQUIPMENT 21,1 }. OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT 2. IN SALES AREA, OPEN TO STRUCTURE WITH NO CEILING: SPRINKLER HEADS ARE TO SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE 3. EXISTING UTILITIES, ETC. THAT ARE DAMAGED DURING THE CONSTRUCTION PERIOD, WHETHER OR SUPPLIED. BE UPRIGHT TYPE. SPRINKLER HEAD TO HAVE FACTORY APPLIED COLOR FINISH. , DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO NOT DUE TO THE CONTRACTOR'S NEGLIGENCE SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR 3 IN NON-SALES AREA, DRYWALL OR LAY-IN CEILINGS: SPRINKLER HEADS ARE TO BE ", ;. COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL AND LEFT IN A CONDITION SUITABLE TO THE LANDLORD AND TENANT'S PROJECT MANAGER. 7. INSULATE ALL HOT WATER, COLD WATER AND INTERIOR CONDENSATE PIPING WITH 1" THICK (K=0.23 ' ' , , . z Q 75 F) PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME RECESSED TYPE. HEAD AND ESCUTCHEON ARE TO BE WHITE. BE FURNISHED AND INSTALLED AS PART OF CONTRACT. 4. IN NON-SALES AREA, OPEN TO STRUCTURE WITH NO CEILING: SPRINKLER HEADS ARE l -.' /1 L. SLEEVES SPREAD AND SMOKE DEVELOPED RATINGS. � f TO BE UPRIGHT TYPE. � r' ,:r ' ti x 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE 8. INSULATE THE TRAP SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH 1 2" ARMSTRONG ‘'. ; '" w,. LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING 1 . THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE „ „ „ 1/2" 2. PIPING: THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR ARMAFLEX PIPING INSULATION OR TRUEBRO MODEL 102W HANDI LAV GUARD" INSULATION KIT. k�. , DRAWINGS UNLESS SPECIFICALLY NOTED OTHERWISE, PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE A. SCHEDULE 40, BLACK STEEL PIPE, ASTM A-53 FOR FERROUS PIPING, WELDED AND SEAMLESS, 'MM �' ' ' FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE 9. INSTALL ALL NECESSARY PIPE HANGERS, SADDLES, AND CARRIERS TO PROPERLY SUPPORT ALL LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS PIPING AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING PROVIDED AND BE SPACED AT A ANSI B-36-10-70 FOR WROUGHT STEEL PIPE. 4. ALL MECHANICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, B. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2 INCHES AND SMALLER. SERVICING, MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING MAXIMUM SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODES. SCREWED OR CAST IRON FLANGED JOINTS FOR PIPES LARGER THAN 2 INCHES. SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND/OR FLOORS SHALL BE FIRE SEALED C. GALVANIZED OR BLACK MALLEABLE IRON WITH BRASS SEAT SCREWED UNIONS FOR PIPES 2 "RTV"CALCIUM SILICATE, SILICONE RTV FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS 10. STERILIZE WATER SYSTEM IN ACCORDANCE WITH LOCAL CODES. INCHES AND SMALLER. 5. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD ENGINEERING TO RETAIN THEIR FIRE RATING. D. VICTAULIC TYPE COUPLINGS ARE ACCEPTABLE, WHERE APPROVED BY CODE AND THE LANDLORD. PRACTICES. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT 11 . CLEAN-OUTS AND FLOOR DRAINS SHALL BE INSTALLED PER LOCAL CODES. WALL COVERS ARE TO BE FOR OTHER THAN MASONRY PARTITIONS, THROUGH STAINLESS STEEL AND FLOOR COVERS ARE TO BE BRASS. PROVIDE FLOOR COVERS WITH INSET AREA 3 A FIRE PROTECTION SYSTEM TAP IS NORMALLY FURNISHED BY THE LANDLORD VERIFY IN FIELD STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR CARPETED LOCATIONS. ALL CLEAN-OUT LOCATIONS SHALL BE APPROVED BY TENANT'S PROJECT ' 6. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. PRIOR TO BID. SPRINKLER SPACING SHALL NOT EXCEED 130 SQ. FT. IN "SALES" AREAS AND 100 COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND GALVANIZED STEEL MINIMUM. MANAGER. SO. FT. IN "STOCK" AREAS, COMPLY WITH LANDLORD'S DESIGN CRITERIA AND LOCAL CODES IF SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER IS MORE 12. ESCUTCHEONS SHALL BE CHROME PLATED, SIZE AS REQUIRED AND PLACED AT ALL PIPE MORE STRINGENT. PIPE SIZING SHALL BE BASED ON NFPA ORDINARY HAZARD. STRINGENT, M. HANGERS , PENETRATIONS AT WALLS, FLOORS, AND CEILINGS IN FINISHED AREAS. 4. ALL SPRINKLER LINES SHALL BE INSTALLED CONCEALED, AS HIGH AS POSSIBLE, AVOIDING C. CODES 1 . HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C-CLAMPS WITH 13. LEAKAGE TESTS SHALL BE PER LOCAL CODES, MINIMUM AS FOLLOWS: INTERFERENCE WITH LIGHT FIXTURES, DUCTS, PIPES, STORAGE DECK, ETC. FIRE PROTECTION , RETAINING CLIPS, CHANNELS, HANGER RODS, ETC. , NECESSARY FOR THE INSTALLATION OF WORK. CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS INDICATING THE LOCATIONS OF ALL H B K 1 , ALL WORK SHALL CONFORM TO THE LANDLORDS' CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND A. TEST WATER PIPING AT 100 PSIG FOR SIX HOURS. SPRINKLER HEADS, SPRINKLER LINES, LIGHTS, DIFFUSERS, GRILLES AND REGISTERS PRIOR TO CONSULTANTS, LTD LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. INSTALLATION. , OTHER APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE I NTO AND COMPLY HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF B. TEST DRAIN, WASTE, VENT PIPING BY A 10 WATER COLUMN FOR TWO HOURS. Mechanical & Electrical Design Services WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE BAR JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE 5. WHERE POSSIBLE, REWORK THE EXISTING SPRINKLER SYSTEM TO MEET THE NEW REQUIREMENTS OF ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE 14. FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THIS DESIGN, RELOCATE ALL MAINS AND BRANCHES INTERFERING WITH CEILING HEIGHTS, LIGHT BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER CRITERIA. USE A LANDLORD APPROVED ROOFING CONTRACTOR WHERE APPLICABLE. 171 Charring Cross Drive S. TYPES AND INSTALLATION METHODS ARE ALSO SUBJECT TO LANDLORD CRITERIA. � FIXTURE PLACEMENT, DUCTWORK, EQUIPMENT, AND MAJOR COMPONENTS INCLUSIVE OF ADJACENT Suite 1B ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY THE TENANT TO THE 15. PROVIDE WATER METER AND REMOTE READER PER LANDLORDS CRITERIA OR LOCAL UTILITIES TENANTS AND MALL COMMON AREAS. REMOVE ALL UNUSED PIPING. Westerville, Ohio 43081 CONTRACTOR. REQUIREMENTS IF APPLICABLE. REFER TO PLANS TO DETERMINE IF WATER METER IS REQUIRED. 614.882.1199 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER 6. FURNISH AND INSTALL A VALVED TEST CONNECTION IN AN ACCESSIBLE LOCATION FOR THE FAX 614,882,1857 D. LICENSES, PERMITS, INSPECTIONS & FEES OF INSULATION. INSTALL 6" LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND - • ( NOT A ) SPRINKLER SYSTEM AS REQUIRED OR REQUESTED BY THE MALL, LOCAL INSPECTOR, OR INSURANCE THE PIPE INSULATION, CARRIER. COORDINATE LOCATION WITH TENANT'S PROJECT MANAGER AND LOCAL FIRE PROTECTION 1 . THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES 1 . �'� ISH AND INSTALL A COMPLETE GAS PIPING SYSTEM IF APPLICABLE. REFER TO PLANS Ti OFFICIAL PRIOR TO ROUGH-IN. . REQUIRED OR RELATED TO HIS WORK, 4, HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI-ELECTRICALLY SEPARATED. OETE" E IF A GAS SYSTEM IS REQUIRED. 7, WHEN COMPLETED, THE ENTIRE FIRE PROTECTION PIPING SYSTEM SHALL BE HYDROSTATICALLY Drawings and irillen material appearing herein constitute original 2. FURNISH TO THE TENANT'S PROJECT MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL 5. PROVIDE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODE. TESTED AS REQUIRED BY THE RULES AND REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION. and unpublished loll( of the Architect and may not be duplicated, INSPECTION APPROVAL AT COMPLETION OF PROJECT. 2. GAS LINES SH BE BLACK STEEL, SCHEDULE 40, ASTM A-53 OR ASTM A106, W MALLEABLE SYSTEM SHALL SHOW NO SIGNS OF LEAKAGE OR OTHER DEFECTS. THIS CONTRACTOR SHALL BE THREADED FITTIN OR 2" AND SMALLER, AND WITH WELDED JOINTS FOR 2- AND LARGER. used or disclosed without written consent of the Architect N. FINAL HVAC INSPECTIONS RESPONSIBLE FOR DAMAGE TO THE WORK OF THE OTHER CONTRACTORS OR TO THE BUILDING, OR TO (D IM B H ARCH I T E C T - 2 0 1 0 E. TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS ITS CONTENTS, PEOPLE, ETC., CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED BY HIM. 1 , ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, TENANT SHALL HAVE AN 3. FURNISH AND INSTALL A G' COCK, DIRT LEG, AND UNION CONNECT ■ ' TO EACH PIECE OF ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE Al THIS CONTRACTOR'S EXPENSE. 1 . WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, INDEPENDENT HVAC CONTRACTOR INSPECT THE FINISHED HVAC INSTALLATION UPON COMPLETION FOR EQUIPMENT. OA0C THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS COMPLIANCE WITH THE PLANS, SPECIFICATIONS AND CODES. THE INSTALLING CONTRACTOR WILL BE 8. PROPERLY COMPLETED AND SIGNED "SPRINKLER CONTRACTOR'S MATERIAL AND TEST CERTIFICATES" RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT HVAC CONTRACTOR UP TO PLANS 4 PITCH PIPING AT A UNIFORM GRADE OF 4" IN 15 FE PWARD IN DIRECTION OF FLOW CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO SHALL BE FURNISHED TO THE LANDLORD, AUTHORITIES HAVING JURISDICTION, AND TENANT'S No. Dole Issue APPROVAL IN WRITING BY TENANT'S PROJECT MANAGER PRIOR THROUGH SHOP DRAWING SUBMITTAL SUPPORT PIPING EVERY 5 FEET. SUPPORT A 'EQU '" i BY LANDLORD CRITERIA, AS DETAILED ON ' AND SPECIFICATION REQUIREMENTS. DRAWINGS, OR BY STANDARD INDUSTRY PRACTI '; 4 ICHEVER IS MORE STRINGENT. PROJECT MANAGER. 05/28/10 100% SET PROCESS, FOR ACCEPTANCE PRIOR TO INSTALLATION. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ANY CHANGES TO ELECTRICAL SERVICE, STRUCTURAL FRAMING, ETC. OR ANY OTHER MODIFICATION 0. OPERATION MANUALS AND INSTRUCTIONS 5. GAS PIPING EXPOSED ON ROOF MUST B INTER WITH RI -INHIBITING PAINT, 9. SPRINKLER HEADS LOCATED IN CEILINGS OR WALLS BELOW 8'-0" ABOVE THE FINISHED FLOOR AND 05/28/10 VT PACKAGE THAT IS REQUIRED BY THIS CONTRACTOR OR OTHER TRADES FOR USE OF ALTERNATE EQUIPMENT AND ABOVE STORAGE DECKS ARE TO BE CONCEALED. WILL COORDINATE CHANGES REQUIRED WITH OTHER TRADES AND SHALL INCLUDE ALL COSTS IN BID 1 . CONTRACTORS SHALL FURNISH OPERATING AND MAINTENANCE INSTRUCTIONS AT THE COMPLETION OF 07/02/10 100% COMPLETE SET FOR THE REQUIRED CHANGES. THE USE THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE 6. GAS PIPING INSTALLED IN R 'N AIR PLENUMS SHALL BE SLEE • 5 AND VENTED OR WELDED IN THE PROJECT. SUBMIT THREE HARD BOUND COPIES TO TENANT'S PROJECT MANAGER. 10 FURNISH AND INSTALL 10 LB. TYPE "ABC" FIRE EXTINGUISHERS, WITH CABINETS IF REQUIRED SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. ACCORDANCE WITH THE L� GAS COMPANY, LOCAL CODE, AND APPLI - E NFPA 54 CODES. AND AT LEAST A "2A1OBC" RATING. LOCATIONS TO BE ESTABLISHED IN THE FIELD BY TENANT'S 07/28/10 LANDLORD SET 2. CONTRACTOR SHALL SCHEDULE A MEETING WITH THE TENANT'S PROJECT MANAGER AT THE SITE TO PROJECT MANAGER AND THE LOCAL FIRE PROTECTION OFFICIAL. MAXIMUM TRAVEL DISTANCE 08/13/10 PERMIT/BID SET 7. TESTING AND PU` 'G OF GAS PIPING SHALL BE DONE PER THE REQUIREMENT • THE LOCAL GAS 2. SUBMIT SIX COPIES OF A COMPLETE AND ALL INCLUSIVE LIST OF ALL EQUIPMENT AND MATERIALS DETAILED OPERATING AND MAINTENANCE OF EQUIPMENT TO STORE PERSONNEL. COMPANY, Le CODES, AND APPLICABLE NFPA 54 CODES. BETWEEN EXTINGUISHERS SHALL BE 75 FEET OR LESS AS REQUIRED BY LOCAL CODES. PROPOSED FOR USE ACCOMPANIED BY MANUFACTURER'S DATA SHEETS GIVING SIZES, CAPACITIES, ETC. FOR REVIEW BY TENANT'S CONSULTANT/TENANT'S PROJECT MANAGER. DATA SHALL BE END OF SECTION 15300 FORWARDED IN A SINGLE PACKAGE WITHIN 15 DAYS AFTER AWARD OF CONTRACT. SUBMISSIONS SHALL END OF SECTION 15000 B. CONT. ' AND COORDINATE GAS SERVICE, METER AND REGULATOR REQUIREMENTS WITH THE 0.41 GAS BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOR (5) WORKING DAYS FOR TENANT'S "•r"ANY AND THE MALL'S OPERATIONS MANAGER PRIOR TO BID. INCLUDE INSTALLATION COST • DIVISION 15 - MECHANICAL CONSULTANT/TENANT'S PROJECT MANAGER REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS IN THE GAS METER AND REGULATOR IN BID. SECTION 15500 JOB'S PROGRESS. CONTRACTOR SHALL NOT INSTALL ANY NON-SPECIFIED OR NON-SCHEDULED DIVISION 15 - MECHANICAL HEATING, VENTILATION, AND AIR CONDITIONING EQUIPMENT WITHOUT TENANT'S PROJECT MANAGER APPROVAL, END OF SECTION 15200 SECTION 15200 A. SCOPE OF WORK F. GUARANTEE PLUMBING DIVISION 15300- MECHANICAL 1 . THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, 1 . THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK PROVIDED UNDER HIS CONTRACT AND A. SCOPE OF WORK SECTION 15300 TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE SHALL MAKE GOOD, REPAIR OR REPLACE AT HIS OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, FIRE PROTECTION FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE MECHANICAL OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF 1 . THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY TENANT'S PROJECT MANAGER. EXTENDED TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE A. SCOPE OF WORK JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: WARRANTIES ARE AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL WORK FOR THE PLUMBING SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB 1 . THIS CONTRACTOR MUST USE A LANDLORD APPROVED FIRE PROTECTION CONTRACTOR TO PERFORM ALL A. HVAC UNITS, EQUIPMENT, AND APPURTENANCES (UNLESS NOTED OTHERWISE). CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: FIRE PROTECTION WORK. ALL COSTS MUST BE INCLUDED IN THIS CONTRACTORS BID. FIRE G. RECORD DRAWINGS B. DUCTWORK, FITTINGS, DAMPERS, AND INSULATION, PROTECTION CONTRACTOR MUST COMPLY WITH ALL SECTIONS OF THIS SPECIFICATION AND INCLUDE --- - - -- - - - - 1 . THIS CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS ON THE JOB SITE TO RECORD A. COMPLETE SANITARY PIPING SYSTEMS OF WASTE, DRAINS, AND VENTS. SAME IN BID. D. REFRIGERANT PIPING (AS APPLICABLE, REFER TO PLANS) . DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: B. COMPLETE COLD AND HOT WATER PIPING SYSTEMS, APPURTENANCES AND INSULATION. E. CURBS, ROOFING, AND STEEL FRAMING FOR SUPPORT (AS APPLICABLE, REFER TO PLANS). C. FIXTURES AND EQUIPMENT AS SCHEDULED. __ _ _ _ _ 2. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, F. TESTING, ADJUSTING, AND BALANCING. A. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. - . . . . = TRANSPORTATION AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE G. TEMPERATURE CONTROL SYSTEM. B. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. E. COMPLETE CONDENSATE DRAIN SYSTEM FROM THE HVAC UNIT TO THE CODE APPROVED FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE SPRINKLER DISCHARGE POINT(AS APPLICABLE, REFER TO PLANS). SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL VISIT THE JOBSITE AND EXAMINE THE C. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT F. TESTS AND ADJUSTMENTS. JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAC SYSTEM, MATERIALS, Project No. 44122/10038 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY 2. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, A. INSTALLATION OF NEW WET SPRINKLER SYSTEM AS REQUIRED TO PROVIDE COVERAGE IN AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND ACCORDANCE WITH EXISTING CONDITIONS, NFPA-13, LOCAL CODES, LANDLORD'S CRITERIA, THEREON. A SET OF REPRODUCIBLE DRAWINGS ALONG WITH ONE SET OF BLULINES OF THE MOST INTEGRATE THE VARIOUS ELEMENTS OF THE PLUMBING SYSTEM, MATERIALS, AND EQUIPMENT WITH AND INSURANCE CARRIERS FOR THE MALL AND THE TENANT. 3. RELOCATION OF EXISTING DUCT MAINS OR BRANCHES TO MEET STORE DESIGN CRITERIA MUST BE Scale AS NOTED RECENT SET OF DRAWINGS WITH TEMPERATURE CONTROL DRAWINGS INCLUDED SHALL BE DELIVERED OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. B. TAPS, RISERS, LATERALS, BRANCHES, VALVES, ALARMS, SPRINKLER HEADS AND ALL INCLUDED IN BID PROPOSAL. TO THE TENANT'S PROJECT MANAGER UPON COMPLETION OF THE WORK AND PRIOR TO FINAL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM. ACCEPTANCE OF THE PROJECT. 3. RELOCATION OF EXISTING WATER, GAS, WASTE, VENT, OR DRAINAGE LINES TO FACILITATE STORE C. DESIGN DRAWINGS, HYDRAULIC CALCULATIONS, SUBMITTALS AND APPROVALS. B. HVAC EQUIPMENT rr o r n8r: DESIGN CRITERIA MUST BE INCLUDED IN BID PROPOSAL. D. PERMITS, FEES, AND CHARGES. p WDB/KH H. DISCREPANCIES IN DOCUMENTS E. TESTS AND TEST CERTIFICATES. 1 . PRIMARY HEATING AND AIR CONDITIONING UNITS ARE TO BE FURNISHED AND INSTALLED AS B. EQUIPMENT AND INSTALLATION F. FIRE EXTINGUISHERS. SCHEDULED UNLESS NOTED OTHERWISE. REFER TO PLANS FOR REQUIREMENTS. ALL EQUIPMENT SHALL 1 . DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL INCLUDE A FIVE (5) YEAR COMPRESSOR AND TEN (10) YEAR HEAT EXCHANGER WARRANTY. LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE 1 , REFER TO PLANS FOR SCHEDULES OF EQUIPMENT AND FIXTURES AND ACCEPTABLE EQUALS. 3. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, Z. MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND J:\2010 Jobs\too3s\US22aosr•d CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE TENANT'S + 2. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT WITH ALL DEVICES, APPURTENANCES, AND 1 PROJECT MANAGER IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF INTEGRATE THE VARIOUS ELEMENTS OF THE FIRE PROTECTION SYSTEM, MATERIALS, AND EQUIPMENT ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON 'MI N BID. OTHERWISE, TENANT PROJECT MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. CONTRACTOR SHALL USE THE DRAWINGS AND SPECIFIED HEREIN. 0 CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. APPROVED INDUSTRY FIRE SPRINKLER STANDARDS FOR REUSING EXISTING FIRE SPRINKLER BRANCHES Droving No. AND SUBMIT CALCULATIONS TO TENANT'S PROJECT MANAGER UPON REQUEST OR REWORK SYSTEM TO 3. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. MECHANICAL `n' TENANT PROJECT MANAGER'S SATISFACTION. ALL AIR CONDITIONING EQUIPMENT MUST BE TRAPPED IN ACCORDANCE WITH MANUFACTURERS DATA. ISEE DRAWINGS FOR ADDITIONAL DETAILS. SPECIFICATIONS 1 NTS 1 MECHANICAL SPECIFICATIONS M 5 .1 s ,. AIR BALANCE REVIEW CHECKLIST C. METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED H. SUPPLY AIR TAKE-OFF FITTINGS M. REFRIGERANT PIPING: 1 , NO DUCTWORK SHALL BE FABRICATED PRIOR TO JOB SITE VISIT AND APPROVAL BY THE GENERAL COMPLETED B BALANCE CONTRACTOR CONTRACTOR. A SKETCH MUST BE SUBMITTED INDICATING SIGNIFICANT DEVIATIONS FROM DESIGN 1 , FURNISH AND INSTALL CONICAL OR BELL-MOUTH TAKE-OFFS FROM MAIN DUCTWORK TO ROUND 1 . THIS CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE REFRIGERANT PIPING SYSTEM BETWEEN L AND MUST BE APPROVED BY TENANT'S PROJECT MANAFER PRIOR TO FABRICATION OR INSTALLATION. BRANCHES. INSTALL PER MANUFACTURER'S INSTRUCTIONS AND DETAILS. THE INDOOR FAN UNITS AND OUTDOOR FAN UNITS, IF APPLICABLE. A COPY OF THIS CHECKLIST MUST BE COMPLETED AND INCLUDED WITH BALANCE REPORT 2, EXCEPT AS OTHERWISE INDICATED, FABRICATE AND INSTALL RECTANGULAR AND ROUND DUCTWORK I . DAMPERS 2. PIPING DIVISION: WITH GALVANIZED STEEL, IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARDS" 1 . FURNISH AND INSTALL MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE A. REFRIGERANT PIPING SHALL BE TYPE "L" HARD DRAWN COPPER TUBING (ASTM B88). TUBING CENTER: STORE NUMBER: OF THE LATEST EDITION, WHERE OTHER CODES ARE ENFORCED, (IE. UMC, IMC, ETC.) USE THE OPERATORS AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. SHALL BE CLEAN, CAPPED AND NITROGEN CHARGED. MOST STRINGENT CODE FOR DUCT CONSTRUCTION STANDARDS, B. ALL FITTINGS AND JOINTS SHALL BE WROUGHT COPPER OR CAST BRONZE (ANSI B16.22). CONTRACTOR: 3. EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO THE FOLLOWING PRESSURE J. FIRE DAMPERS AND SMOKE/FIRE DAMPERS ALL COPPER TO COPPER JOINTS SHALL BE BRAZED WITH A COPPER-PHOSPHORUS ALLOY AND DATE: FAX NUMBER: CLASSIFICATIONS: ALL OTHER JOINTS SHALL BE BRAZED WITH SILFOS-5 ALLOY. 1 . FURNISH AND INSTALL FIRE DAMPERS OR SMOKE/FIRE DAMPERS WHERE INDICATED OR REQUIRED BY C. ALL ELBOWS ARE TO BE LONG RADIUS TYPE. SUPPLY DUCTS: 2" W.G. , POSITIVE CODES. DAMPERS SHALL BE DESIGNED FOR HORIZONTAL OR VERTICAL FLOW OF AIR AS REQUIRED. FIRE DAMPERS SHALL BE UL LABELED TO MEET UL#555 AND MEET ALL CODE REQUIREMENTS. 3. INSTALLATION SYSTEM INDEX RETURN AND EXHAUST DUCTS: 2" W.G. , NEGATIVE SMOKE/FIRE DAMPERS SHALL BE UL LABELED TO MEET UL#555S AND MEET ALL CODE REQUIREMENTS. SYSTEMS: 1. VAV US220 ACCEPTABLE (CHECK-/) A. SUCTION LINES SHALL HAVE ADEQUATE LIFT TRAPS AND/OR DOUBLE SUCTION RISERS TO (CHECK-/) 2, VAV - FAN POWERED EXCEPT WHERE OTHERWISE INDICATED, USE DUCT SEALANTS OF THE FOLLOWING PRESSURE 2. FIRE DAMPERS SHALL HAVE THE BLADES OUT OF THE AIRSTREAM AND A 1650- FUSIBLE LINK, TYPE THE REQUIREMENTS OF FIELD CONDITIONS AND EQUIPMENT MANUFACTURER'S 3. ROOFTOP CLASSIFICATIONS: B, AS M I N 1 MUM. FURNISH AND INSTALL ACCESS DOORS AS NECESSARY. RECOMMENDATIONS. APPL I CABLTHSYSATEMS - CHECK 4. SPLIT DX OR BUILT-UP ON WASHINGTON SQUARE B. BRAZE ALL JOINTS WITH SILFOS-5 STARTING AT THE INDOOR UNIT AND WORKING TOWARD THE ALL THAT 5 5. RETURN AIR/RELIEF FAN OR SMOKE EXHAUST SUPPLY DUCTS: CLASS B - 3" W,G, 1 2 3 4 5 6 7 UA 6. ELECTRIC BASEBOARD/UNIT HEATER s, " v RETURN AND EXHAUST DUCTS: CLASS C - 2" W.G. 3. FURNISH AND INSTALL ALL NECESSARY FRAMING AND SLEEVES FOR DAMPER MOUNTING PER UL AND OUTDOOR UNIT. THE SEALS ON THE OUTDOOR UNIT SHALL BE BROKEN LAST. A NITROGEN ❑ ❑ ©► ❑ ❑ ❑ Q, ❑ 7. EXHAUST FANS �E H'S CODE REQUIREMENTS. BLEED SHALL BE USED DURING ALL SOLDERING AND ANY TIME THE SYSTEM IS OPEN. ALL UA UNACCEPTABLE OPEN LINES SHALL BE CAPPED AND SEALED BEFORE LEAVING THE SITE DURING POF�TLAIVD� �r IN ACCORDANCE WITH THESE CONSTRUCTION AND SEALANT PRESSURE CLASSIFICATIONS, MAXIMUM K. DUCTWORK INSULATION CONSTRUCTION. PRESSURE TEST FOR LEAKS WITH AN INERT GAS AT TO 245 PSIG. REDO ►�0 ® ❑ ® ® ® ❑ ❑ REPORT PREPARED BY A CURRENT INDEPENDENT NE DUCT AIR LEAKAGE WILL NOT EXCEED 5% AS REQUIRED FOR FINAL AIR BALANCE APPROVAL. LEAKING JOINTS AND RETEST UNTIL SYSTEM IS TIGHT. EVACUATE ENTIRE SYSTEM TO 200 OR AABC LICENSED CONTRACTOR (LICENSE AND C� � RED 4, ROUND AND FLAT OVAL DUCTWORK SHALL BE GALVANIZED STEEL WITH SPIRAL LOCKSEAM 1 . FURNISH AND INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN MICRONS OF MERCURY. CHARGE SYSTEM WITH 25 PSI OF R-22 AND A INERT GAS TO 245 PSI SIGNATURE REQUIRED) 12" INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST AND RETEST SYSTEM WITH HALIDE LEAK DETECTOR. ALL LEAKING JOINTS MUST BE CONSTRUCTION. ROUND DUCTWORK SIZES 12 DIAMETER AND SMALLER MAY BE SNAP-LOCK CONSTRUCTION, ALL SNAP-LOCK SEAMS SHALL BE SEALED AS DESCRIBED IN THESE COMPLY WITH NFPA 90A. COMPLETELY RESEALED UNTIL NO LEAKS EXIST. TURN ON CRANK CASE HEATERS 24 HOURS ® ❑ ® ® ® ❑ ❑ CONFORMANCE CERTIFICATE/PERFORMANCE GUARANTY PRIOR TO STARTING COMPRESSOR TO BE SURE ALL REFRIGERANT LIQUID IS OUT OF THE REGISTERED WITH NATIONAL HEADQUATERS SPECIFICATIONS. DUCT AND FITTINGS SHALL BE G90 GALVANIZED STEEL CONFORMING TO ASTM A- 2. DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. COMPRESSOR. 653 AND A-924, ALL FITTINGS THAT ARE SPOT WELDED OR BUTTON PUNCHED CONSTRUCTION SHALL El ® ❑ ® ® ® ❑ ❑ EQUIPMENT LIST AND CALIBRATION DATE (WITHIN 6 BE INTERNALLY SEALED. ROUND DUCTWORK SHALL BE SPIROSAFE SELF SEALING DUCT SYSTEM AS C. UPON COMPLETION OF TESTING, BUT BEFORE THE REFRIGERANT PIPING INSULATION IS MONTHS OF TEST) MANUFACTURED BY SEALED. OR AN APPROVED EQUAL BY UNITED MCGILL, SEALI OR SPIRO, OR 3. ALL RECTANGULAR SUPPLY AND RETURN DUCTWORK FROM THE HVAC UNIT CONNECTION THROUGH THE APPLIED, THE PIPING MUST BE INSPECTED BY A REPRESENTATIVE OF THE LOCAL GOVERNING APPROVED MANUFACTURED FIRST 6' OF THE FIRST HORIZONTAL SECTION SHALL BE INTERNALLY INSULATED WITH 1" THICK, AUTHORITY AS NECESSARY. El ►�� ❑ ® ® ® ❑ ❑ MAKE AND MODEL # OF EACH PIECE OF EQUIPMENT 1-1/2 LB. DENSITY LINER (C=0.28 0 75 F). LINER IS TO HAVE A COATED SURFACE EXPOSED TO D. INSULATE THE REFRIGERANT SUCTION LINES AND CONDENSATE LINES ONLY WITH RUBATEX OR TESTED 5. ROUND SPIRAL GALVANIZED STEEL DUCTWORK MAY BE USED IN PLACE OF RECTANGULAR DUCTWORK MRSTREAM TO PREVENT EROSION. APPLY ADHESIVES AND MECHANICAL FASTENERS AS RECOMMENDED ARMSTRONG 1 INCH THICK PIPE INSULATION WITH FLAME SPREAD RATING OF NOT MORE THAN WHEN ABOVE CEILING CLEARANCES PERMIT AND EQUIVALENT FREE AREA IS MAINTAINED, WITH THE BY SMACNA AND THE MANUFACTURER TO PREVENT LINER SEPARATION FROM THE DUCT, ALL 25 AND A SMOKE DEVELOPED OF NOT MORE THAN 50 IN ACCORDANCE WITH INDUSTRY NAMEPLATE DATA TRANSVERSE EDGES TO BE COATED WITH ADHESIVE. STANDARDS. DO NO INSULATE THE HOT GAS (LIQUID) LINES OR ANY HOT GAS BYPASS LINES ►_� ►_� FOLLOWING EXCEPTION; ALL SUPPLY AND RETURN DUCTWORK WITHIN 6 FEET OF THE AIR HANDLER IF APPLICABLE. ® ❑ 0 0 ❑ MANUFACTURER OF MOTOR MUST BE RECTANGULAR AND INTERNALLY LINED, WHERE ROUND DUCT SUBSTITUTION WILL TAKE 4 ALL OUTSIDE AIR AND SUPPLY AIR DUCTS SHALL BE EXTERNALLY INSULATED WITH A MINIMUM OF ® ❑ ►�� ►�� ❑ MOTOR HP/BHP PLACE, SUBMIT A SKETCH AND CHART SHOWING EQUIVALENT ROUND CONVERSIONS OF RECTANGULAR 1 1/2" THICK, 1 # DENSITY (R=5.6) DUCT WRAP WITH VAPOR BARRIER. VAPOR BARRIER IS TO 4. INSPECTION DUCTWORK TO TENANT PROJECT MANAGER'S FOR APPROVAL PRIOR TO FABRICATION OR INSTALLATION, BE MAINTAINED THROUGHOUT DUCT SYSTEM. ALL JOINTS MUST BE TAPED SO THAT NO INSULATION ►�� ❑ ►�0 ® ® ❑ UNIT VOLTAGE err'` FIBER IS VISIBLE. EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, A. CONTRACTOR MUST PREPARE AND SUBMIT A COMPLETE PIPING SCHEMATIC TO THE LOCAL HVAC f •6. ALL RECTANGULAR SUPPLY AND RETURN DUCTWORK SHALL BE INTERNALLY LINED FROM THE HVAC UNIT FLOORS, AND SIMILAR PENETRATIONS. EQUIPMENT MANUFACTURER'S REPRESENTATIVE FOR APPROVAL PRIOR TO BEGINNING El ❑ ►11 ►�� ►�� ❑ MOTOR AMPERAGE (AMPS)CONNECTION THROUGH THE FIRST 6 OF THE FIRST HORIZONTAL SECTION. INSTALLATION. UPON COMPLETION OF PIPING, THIS CONTRACTOR MUST CALL THE LOCAL HVAC r ' "(7'7‘0 7. AS A MINIMUM, CROSSBREAK ALL FLAT SURFACES OR REINFORCE WITH A BEAD APPROXIMATELY 3/8" 5• ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE EQUIPMENT MANUFACTURER'S REPRESENTATIVE FOR FIELD INSPECTION OF WORK PERFORMED. ►;� ❑ =� ® ❑ KILOWATTS HEAT (KW) t ,^ WIDE X 3/16" DEEP ON 12" CENTERS TO PREVENT VIBRATIONS, REGARDLESS OF DUCT GAUGE. DEVELOPED RATING OF NO HIGHER THAT 50 WHEN TESTED IN ACCORDANCE WITH ASTM C 411 , OR AS ALL ITEMS FOUND TO BE INADEQUATE FOR PROPER PERFORMANCE BY HVAC EQUIPMENT ►�� ❑ ® :4 ❑ MOTOR RPM REQUIRED BY LOCAL CODES. MANUFACTURER'S REPRESENTATIVE MUST BE CORRECTED AT NO ADDITIONAL CHARGES TO TENANT. 0 ❑ ►mot ►1 ❑ SERVICE FACTOR (SF) 8. INSTALL FACTORY MANUFACTURED DOUBLE THICKNESS TURNING VANES IN ALL RIGHT ANGLE ELBOWS 6. WHEN A COMPLETE DUCTED RETURN AIR SYSTEM IS INDICATED ON THE DRAWINGS, ONLY THE 6'-0" OVER 36" IN LENGTH, INSTALL FACTORY MANUFACTURED SINGLE THICKNESS TURNING VANES IN ALL OF THE RETURN AIR DUCT CLOSEST TO THE AIR HANDLING UNIT IS TO BE INSULATED. N. LABELS/PIPE MARKERS ❑ ® ELI ❑ SHEAVE SIZE/BORE SIZE OTHER ELBOWS, 9, INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA IIYDRONIC rIPING ( NOT APPLICABLE ) 1 . FURNISH AND INSTALL PIPE IDENTIFICATION MARKERS ON ALL PIPES INSTALLED UNDER THIS ❑ 0 C3 Nt ER AND SIZE OF BELTS CONTRACT. MARKERS SHALL BE A MINIMUM OF 1-1/2" X 8" AND IDENTIFIED IN ACCORDANCE WITH STANDARDS. SUPPORT HORIZONTAL DUCTS WITHIN 2 FEET OF EACH ELBOW AND WITHIN 4 FEET OF 1 . FURNISH AND INSTALL A COMPLETE HYDRONIC PIPING SYSTEM IF APPLICABLE. REFER TO PLANS THE BACKGROUND AND LETTER COLORS ISSUED BY THE AMERICAN NATIONAL STANDARDS INSTITUTE UNIT FIELD MEASUREMENTS EACH BRANCH INTERSECTION USING. DOUBLE STRAP HANGERS ON EACH SIDE OF FITTING. SUPPORT TO DETERMINE IF A HYDRONIC SYSTEM IS REQUIRED. (ANSI). MARKERS SHALL BE MANUFACTURED BY CHAMPION AMERICA INC. 800-521-7000, OR EQUAL. El 121 ❑ ® El FIELD VOLTAGE WITH EACH PHASE FOR 3 PHASE VERTICAL DUCTS AT A MAXIMUM INTERVAL OF 16 FEET AND AT EACH FLOOR. NO WOOD SHALL BE MOTORS USED TO SUPPORT OR BRACE DUCTS, PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE 2. •IPING 2. PIPING SHALL BE IDENTIFIED AS FOLLOWS: CHILLED WATER RETURN, CHILLED WATER SUPPLY, AND LOCAL CODES OR BY LANDLORD. CONDENSATE, HOT WATER RETURN, HOT WATER SUPPLY, CONDENSER WATER RETURN, CONDENSER WATER 0 ❑ 0 ❑ 0 El AMP DRAW WITH EACH PHASE FOR 3 PHASE 10. WHERE DUCTS PASS THROUGH ROOFS AND FLOORS, PROVIDE AS MINIMUM 1-1/2"X1-1/2" X1/8" STEEL A. HYDRONIC PIPING FOR CHILLED WATER, CONDENSER WATER AND/OR HEATING WATER SHALL :E SUPPLY, REFRIGERANT LIQUID, REFRIGERANT SUCTION, AND DIRECTIONAL ARROWS. ALL MOTORS ASTM A-120, SCHEDULE 40, ERW, BLACK STEEL PIPE WITH PLAIN ENDS. INSTALL ST 'L IDENTIFICATIONS MUST BE VISIBLE AT EQUIPMENT. ANGLE FRAMES AT EACH SIDE OF OPENING. THE ANNULAR SPACE BETWEEN DUCT AND ANGLE FRAMES 'IPE WITH WELDED JOINTS WHERE PIPE IS 2-1/2 INCH AND"LARGER. INSTALL STEE PIPE ❑ El ® KILOWATTS (KW) ELECTRIC HEATER ONLY SHALL BE CAULKED WITH SILICONE SEALANT OR FIREPROOFED AS REQUIRED BY ASSEMBLY FIRE ITH THREADED JOINTS AND FITTINGS OR INSTALL TYPE "K" ANNEALED TEMPERED Ce'PER 0. CURBS AND STEEL FRAMING FOR SUPPORT H B K RATING. ❑ ❑ FAN RPM T :E WITH SILFOS JOINTS FOR 2 INCH AND SMALLER PIPE. PROVIDE DIELECTRIC NIONS ►1 ❑ •1 „ BE EN DISSIMILAR METALS. ALL PIPING SHALL BE IN STRICT CONFORMANCE W H ASTM, 1 . THIS CONTRACTOR WILL FURNISH AND INSTALL ALL NECESSARY CURBS AND STEEL FRAMING REQUIRED 0 0 0 0 EXTERNAL STATIC PRESSURE-INLET SIDE CONSULTANTS, LTD 11 . ALL JOINTS AND SEAMS SHALL BE SEALED WITH 2 WIDE, GLASS-FIBER-FABRIC REINFORCED TAPE. ASA, AND LANDLORD'S REQUIREMENTS, WHICHEVER I S MOST STRINGENT. UNIONS eR FLANGES TO INSTALL ALL HVAC EQUIPMENT AS DESCRIBED OR IMPLIED ON THE DRAWINGS. CURBS SHALL BE Mechanical & Electrical Design Services JOINTS ALSO SHALL BE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. LIQUID SEALANTS BY MUST 'E USED AT EQUIPMENT CONNECTIONS WHERE SERVICE OR REMOVAL MAY BE 'EQUIRED. A MINIMUM OF 14" HIGH, OF THE SAME MANUFACTURER OF THE EQUIPMENT SUPPORTED UNLESS NOTED ❑ ® 181 ❑ EXTERNAL STATIC PRESSURE-DISCHARGE SIDE UNITED MCGILL CORP. , DOW CORNING, MIRACLE ADHESIVES AND SUREBOND INC. WILL BE ACCEPTED B. ALL PIING AND EQUIPMENT SHALL BE PRESSURE TESTED WITHOUT LEAKAGE AT A MINIMUM OTHERWISE INSULATE UNDER THE COMPRESSOR SECTION TO PREVENT CONDENSATION ALL CURBS IN LIEU OF TAPE. NOTE: FACTORY GASKETED JOINTS DO NOT REQUIRE ADDITIONAL SEALER. PRESSOR. OF 125 PSI , MUST BE INSTALLED SO THAT TOP OF CURBS ARE "DEAD" LEVEL. ALL PENETRATIONS OF EXISTING ® ® ❑ WATER GPM CONDENSER/CHILLED/HEATING 171 Charring Cross Drive S. 12. SOFT ELASTOMER BUTYL GASKET WITH ADHESIVE BACKING SHALL BE USED TO SEAL FLANGED JOINTS. C. ALL HYDR►�NIC PIPING AND EQUIPMENT CONNECTED TO THE HVAC PIPING SYSTEM SHALL BE STRUCTURE SHALL BE DONE IN ACCORDANCE TO THE LANDLORD'S GUIDELINES AT THIS CONTRACTOR'S ►�� ® ❑ SUPPLY WATER TEMPERATURE CONDENSER/ Suite 18 CLEANED A D FLUSHED. REMOVE, CLEAN, AND REPLACE STRAINER SCREEN . FILL TENANT'S EXPENSE. COORDINATE STEEL FRAMING REQUIREMENTS, ROOF PENETRATIONS, AND ROOF FLASHING Westerville, Ohio 43081 SYSTEM WIT' DOMESTIC WATER AND VENT ALL PIPING AND EQUIPMENT PRIOR TO CONNECTION WITH THE GENERAL CONTRACTOR TO DETERMINE SCOPE OF WORK PRIOR TO BID. THIS CONTRACTOR CHILLED/HEATING 614.882.1199 13. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED FAX 614.882.1857 OTHERWISE, TO THE LANDLe D S SYSTEM. CONTRACTOR SHALL NOT FILL TENANT'S STEM WITH WATER MUST RECEIVE WRITTEN APPROVAL BEFORE ANY ADDITIONAL WORK TAKES PLACE. 5D 0 ❑ RETURN WATER TEMPERATURE CONDENSER/ FROM THE LAND ORD'S SYSTEM UNLESS SPECIFICALLY INSTRUCTED TO De SO FROM THE CHILLED/HEATING 14, PROVIDE ACCESS TO ALL MOTORIZED DAMPERS, FIRE DAMPERS, LANDLORD'S Fl D REPRESENTATIVE. P. TESTING, ADJUSTING, AND BALANCING CONTROLS, AND OTHER ITEMS IN DESIGN AND ACTUAL CFM'S (WITHIN 5% OF DESIGN1 D. PRIOR TO CONNE ION TO THE LANDLORD'S SYSTEM, CONTRACTOR SH. L OBTAIN WRITTEN DUCTWORK THAT REQUIRE SERVICE OR INSPECTION. IF THE ACCESS PANEL LOCATION IS EXPOSED AS FOLLOWS: TO THE SALES AREA, I T MUST BE APPROVED BY TENANT'S PROJECT MANAGER PRIOR TO CONFIRMATION FRe', THE LANDLORD'S FIELD REPRESENTATIVE, THA' ALL TESTING,NG, 1 . TESTING, ADJUSTING AND BALANCING OF ALL WORK SHALL BE MADE BY AN I NDEPENDENT CONTRACTOR D r a w i n g s e n d r r i i t e m a t e r i a l appearing h e r e i n c o n s t i t u t e o r i g i n a l FLUSHING, AND PRS•ER FILLING OF THE TENANT'S SYSTEM HAS B' N COMPLETED IN WHO IS A CURRENTLY LICENSED ASSOCIATED AIR BALANCING COUNCIL (AABC) OR NATIONAL 0 ® ❑ ® ❑ AT EACH SUPPLY DIFFUSER end unpublished took of the Architect and coy not be duplicated, INSTALLATION. LAY-IN SUPPLY AND RETURN AIR DIFFUSERS, GRILLES AND REGISTERS WITH ACCORDANCE TO THE LANDLORD'S REQUIREMENTS AND THAT THE T' ANT'S SYSTEM IS READY ENVIRONMENTAL BALANCING BUREAU (NEBB) BALANCING CONTRACTOR. NO OTHER BALANCE REPORTS p 1 p ' PLASTER FRAMES MAY BE USED AS ACCESS LOCATIONS WHEN WITHIN 3'-O" OF written u s e d d or d i s c l o s e d w i t h o u t w r i t t e n c o n s e n t of t h e A r c h i t e c t TO BE CONNECTED TO E LANDLORD'S SYSTEM. WILL BE REVIEWED OR ACCEPTED. ALL BALANCING WORK MUST BE COMPLETE AND DONE IN ® 0 CA ® ❑ C3 AT EACH RETURN AIR GRILLE FOR DUCTED ACCORDANCE WITH THE MOST RECENT STANDARDS OF THEIR SOCIETY AND AS A MINIMUM SHALL RETURN ONLY ®m B H A R C H I T E C T - 2 0 1 0 15. ALL DUCTWORK SHALL BE INSTALLED WITH INSIDE CLEAR DIMENSIONS AS NOTED ON DRAWINGS. 3• VALVES INCLUDE THE INFORMATION AS SHOWN IN THE AIR BALANCE REVIEW CHECKLIST BELOW. PAYMENT WHERE DUCTWORK SIZE IS LARGER THAN CONNECTED DEVICE (IE. VAV BOX, DIFFUSER, REGISTER) OF ALL COSTS FOR TESTING AND BALANCING SHALL BE INCLUDED IN THE BID. 0 ® ❑ 0 ❑ TOTAL SUPPLY AIR BY DUCT TRAVERSES QAOC SMOOTH DUCT TRANSITIONS ARE TO TAKE PLACE JUST PRIOR TO DEVICE CONNECTION. REFER TO A. GATE VALVES, 2-INCH AND •MALLER: CLASS 150, BODY ' D UNION BONNET OF ASTM B 62 DETAILS. CAST BRONZE WITH THREADED OR SOLDER ENDS, INTEGRA SEAT, RENEWABLE SOLID BRONZE 2. TESTING, ADJUSTING AND BALANCING REPORT MUST BE COMPLETE AND TURNED OVER TO TENANT'S ❑ ® ❑ ❑ ❑ TOTAL RETURN/RELIEF/EXH, AIR BY DUCT • WEDGE DISC, RISING STEM, REWED BONNET AND RE- ' KABLE UNDER PRESSURE. BALL PROJECT MANAGER 1 WEEK PRIOR TO MERCHANDISING DATE. THE HVAC CONTRACTOR SHALL VERIFY TRAVERSE Na. Dole Issue • • • •• VALVES NOT APPLICABLE ) ' P VALVES ARE ACCEPTED AS AN 1 AL SUBSTITUTION. THAT ALL EQUIPMENT AND SYSTEMS ARE COMPLETE AND OPERATIONAL ONE WEEK PRIOR TO FINAL ❑ 0 ❑ TOTAL OUTSIDE AIR AND METHOD OF 05/28/10 100% SET B. GATE VALVES, 2-1/2 INCH AND ,ARGER: CLASS 125 CAST IRON BODY, RENEWABLE BRONZE BALANCING. IF ALL SYSTEMS ARE NOT OPERATIONAL AT THE TIME OF THE SCHEDULED BALANCING, TESTING O.A. AMOUNT 1 . WHERE D. .k.RK IS SPECIFICALLY NOTED AS MEDIUM PRESSURE, IT SHALL BE CONTT: .• I IN 05/28/10 VT PACKAGE ACCORDANCE WI �CNA STANDARDS FOR A PRESSURE RATING OF 4 INCHES COLUMN MINIMUM SEATS AND SOLID WEDGE DISC, R SING STEM, FLA :ED ENDS, AND RE-PACKABLE UNDER IT SHALL BE THE HVAC CONTRACTOR S SOLE RESPONSIBILITY TO PAY ALL COSTS INCURRED FOR PRESSURE. ADDITIONAL TESTING AND BALANCING INCLUDING ALL LABOR, TRAVEL EXPENSES, MEALS, HOTEL ® ® ❑ ® ❑ ❑ PLAN INDEXING EACH DIFFUSER/GRILLE TESTED 07/02/10 100% COMPLETE SET OR GREATER AS REQUI• : ' LANDLORD. C. SWING CHECK VALVES, 2-INCH AND 'LLER: C SS 150, CAST BRONZE BODY AND CAP COSTS, ETC. CONFORMING TO ASTM B 62 WITH NOR ONTAL NG, Y-PATTERN, RENEWABLE BRONZE DISC, VERIFICATION OF OPERATIONAL STATUS 07/28/10 LANDLORD SET 2. ALL GAUGES AND REINFORCEMENT MUST ' WITH TH • ST EDITION OF SMACNA STANDARDS FOR AND HAVING THREADED OR SOLDERED E IS. 3. THE HVAC CONTRACTOR SHALL BE PRESENT FOR AIR BALANCE TO VERIFY ACCESSIBILITY TO ALL MEDIUM PRESSURE DUCT AND WITH THE LANDIeN RITERIA. D. SWING CHECK VALVE, 2-1/2 INCH AND URGE': CLASS 125 CAST IRON BODY AND BOLTED DEVICES, VERIFY ALL OPERATING SEQUENCES AND INSTALL NEW FILTERS IN ALL UNITS JUST PRIOR ® ►�1 ❑ ►�1 ❑ SPACE BALANCE AND SET POINT AFTER 08/13/10 PERMIT/BID SET 3, CONNECTIONS TO THE LANDLO'�'' DIUM PRESSURE DUCTWORK BE MADE WITH "LO-LOSS" CAP, HORIZONTAL SWING, RENEWABLE BR. Z DISC, FLANGED ENDS AND CAPABLE OF BEING TO THE AIR BALANCE. THE HVAC CONTRACTOR SHALL ALLOW TWO DAYS ON SITE FOR BALANCING. THE SADDLE TENS TO BY -D '' ' CORP. , OR RE OTHERWISE UWO REQUI ' : THE HALO-LO. REFITTED WHILE THE VALVE REMAINS IN LINE. COMPLETE AIR BALANCE SHALL TAKE PLACE WITH OUTSIDE AIR DAMPERS IN MINIMUM POSITION, ® ►�1 ❑ ® ❑ SUPPLY TEMPERATURES (AT 100% COOLING & E. COMBINATION BALANCING AND SHUT-OFF V ES: BELL & GOSSETT CIRCUIT SETTER WITH EXCEPT AS NOTED OTHERWISE. HVAC CONTRACTOR SHALL ALSO INSTALL A NEW SET OF FILTERS ONE 100% HEATING) 4. ALL e - ITEMS FROM METAL DUCTWORK SPECIFICATION SECTION APPLY TO THIS SE :� WITH LOCKING SET POINT. A CIRCUIT SETTER :AL NCE WHEEL MUST BE INCLUDED WITH 0 & M DAY PRIOR TO MERCHANDISING. ® 0 CA ❑ OUTSIDE db/wb READING AT TIME OF BALANCE EXCEPTION THAT ALL MEDIUM PRESSURE DUCTWORK MUST BE WRAPPED INSULATION, NOT L MANUAL. TACO OR GRISWALD ARE CONSI%FRED S EQUAL. 4. BALANCE AIR AND WATER QUANTITIES TO WITHIN + 5% OF THAT INDICATED ON THE DRAWINGS. ANY ❑ ❑ ECONOMIZER SETTING (A/B/C/D) IN ROOFTOP 4, PIPING SPECIALTIES REQUIRED CHANGES IN SHEAVES, BELTS OR PULLEYS NEEDED TO ACHIEVE SPECIFIED FLOW RATES UNITS E. VIBRATION ISOLATION DEVICES • SHALL BE PERFORMED BY THE HVAC CONTRACTOR WITH NO ADDITIONAL COST TO THE TENANT. t . VIBRATION ISOLATION DEVICES SHALL BE FURNISHED AND INSTALLED IN ALL SUPPORTS BETWEEN A. PRESSURE/TEMPERATURE TEST PLUS ( PETE'S PLU' - 1/4 INCH NPT FITTINGS TO RECEIVE ❑ Egl ❑ ADJUST AND VERIFY ECONOMIZER RELIEF FAN VIBRATING ISOLATION DEVICES AIR SHALL HANDLERS,FURNISHED ETC.) AND INSTALLED EITHER A TEMPERATURE OR PRES` RE PROBE, 1/8 I .H O.D. FITTING AND CAPS SHALL BE 5. ALL CONTROL SEQUENCES SHALL BE TESTED (INTERLOCKED EQUIPMENT, SMOKE DETECTORS, SMOKE GOES ON AT 60% OUTSIDE AIR BRASS WITH VALVE CORE OF e, DEL, RATED AT 400 , IG, OOF TO 2000F. EVACUATION, ECONOMIZER, ETC.) AND OPERATING STATUS RECORDED IN THE REPORT. B. STRAINERS - "Y" PATTERN ST'A I NERS 125 PSIG, CA ' IRON BODY WITH PERFORATED ❑ 0 0 0 MAXIMUM CFM RELIEF WITH ECONOMIZER AT 2. VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING STAINLESS STEEL SCREEN, T 'FADED FOR 2 INCHES AND SMALLER, FLANGED FOR 2-1/2 6. SEVEN COPIES OF THE BALANCE REPORT SHALL BE SUBMITTED THROUGH THE GENERAL CONTRACTOR 100% OUTSIDE AIR DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH INCHES AND LARGER. SCRE'N OPENING SIZE AT 0.033 I CH FOR HEATING AND 1/8 INCH TO TENANT'S PROJECT MANAGER FOR APPROVAL. HOUSED SPRING MOUNT DEVICES. FOR CHILLED OR CONDENS WATER. PROVIDE WITH BO D►`' VALVE WITH HOSE END ►.1 ❑ UNIT HEATER OPERATIONAL STATUS AND SET FITTING. 7. THE BALANCING CONTRACTOR SHALL PERFORM ALL APPLICABLE TESTING AND BALANCING FUNCTIONS POINT 3. EXAMINE DEAD LOAD AND OPERATING LOAD CONDITIONS WHEN SELECTING DEVICES. ADJUST FOR C. THERMOFLO INDICATOR BELL & GOSSETT MODEL "TFI". REQUIRED FOR THE SYSTEM DESIGNED ON THESE DRAWINGS. ALL SYSTEMS UNABLE TO BE ❑ ►1 0'.,1 ❑ TEST OF SUPPLY FAN SHUTDOWN IN ALARM PROPER ALIGNMENT AND LOADING, AVOID "GROUNDING" THE ISOLATOR. COMPLETELY BALANCED AT THE TIME OF ORIGINAL BALANCE MUST BE BALANCED IN FUTURE AT NO SEQUENCE 5. INSULATION ADDITIONAL EXPENSE TO TENANT. THE BALANCING CONTRACTOR SHALL RECHECK ANY ITEMS THAT 4, CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND AT THE UPPER AND ►_� TENANT DEEMS NECESSARY AT NO ADDITIONAL COST TO TENANT. ® ❑ TEST OF SMOKE EXHAUST FAN ON IN ALARM LOWER ATTACHMENTS TO STRUCTURES, DUCTS, EQUIPMENT, ETC. A. ALL HYDRONIC PIP G FOR CHILLED WATER AND/OR HEATING WATE• (NOT INCLUDING SEQUENCE 5. CONSULT MANUFACTURER FOR APPLICATION DATA. CONDENSER WATER LESS SPECIFICALLY NOTED OTHERWISE), VALVE, FITTINGS, AND 8. THE BALANCE REPORT SHALL BE ON THE AABC NATIONAL STANDARD REPORT FORMS OR THE NEBB ACCESSORIES SH L BE INSULATED. FOR PIPE SIZES UP TO 2 INCHES, INSULATE WITH 1 CERTIFIED REPORT FORMS AS PUBLISHED IN THEIR MOST CURRENT EDITIONS AND SHALL INCLUDE ❑ THE A/B REPORT SUBMITTED FOR THE ABOVE LOCATION HAS BEEN REJECTED, NOTE INCH THICK ( 0.23 0 75 F) FIBERGLASS INSULATION WITH ALL SER ICE JACKET AND THE FOLLOWING CHECKLIST: CHECKS IN COLUMN HEADED "UA" (UNACCEPTABLE) AND REMARKS BELOW. F. FLEXIBLE CONNECTIONS VAPOR BARRI FOR PIPE SIZES 2-1/2 INCHES AND LARGER, INSULA WITH 1-1/2 INCH THICK (K=0 3 0 75 F) FIBERGLASS INSULATION WITH ALL SERVICE JA► ET AND VAPOR ❑ THE A/B REPORT SUBMITTED FOR THE ABOVE LOCATION HAS BEEN APPROVED. 1 . FLEXIBLE COLLARS SHALL BE FURNISHED AND INSTALLED IN ALL CONNECTIONS BETWEEN VIBRATING BARRIER END OF SECTION 15500 Project No. 44122/10038 EQUIPMENT (FANS, AIR HANDLERS, ETC.) AND DUCTS OR CASINGS. ALSO, FURNISH AND INSTALL B. INSULATI' AT ALL HANGERS FOR PIPING 2 1/2 INCHES AND LARGER SHALL BE HARD AND APPROVED BY: DATE: FLEXIBLE CONNECTIONS WHERE DUCTS CROSS BUILDING EXPANSION JOINTS. NON-CD ' ESSIBLE. REMARKS:, OF NEOPRENE-COATED FLAMEPROOF FA RI 1 C. ALL IN' LATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 'ND A SMOKE ScoIe AS NOTED 2. FLEXIBLE CONNECTIONS SHALL BE CONSTRUCTED 0 B C. PROV DE DEVELOPED RATING OF NO HIGHER THAT 50 TO CONFORM WITH THE REQUIREMEN , OF THE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF NFPA VIBRATION. D. PRO IDE ZESTON OR EQUAL INSULATION FITTINGS FOR ALL TEES, ELLS OR SPECI LTY Oroen6y: VIRM KH G. FLEXIBLE AIR DUCT Fl TINGS. t . FLEXIBLE AIR DUCT SHALL BE 1" INSULATED CLASS 1 AND RATED FOR THE OPERATING PRESSURE 6. GENE' •L INSTALLATION SEE SHEET M2.1 D FOR LOFT ECSYSTEM, DUCT CONSTRUCTION ATERIAL (PLASTIC, CLOTH, ALUMINUM) MUST ADHERE TO A. INSTALL WATER MAINS WITHOUT PITCH. USE ECCENTRIC REDUCING COUPLINGS AT CHANt S TEMPERATURE CONTROL BALANCE CONTRACTOR T O ,r\2O1O \loo uS22 1.a.g BE IN SIZE WITH THE TOP OF PIPES AT SAME ELEVATION. BRANCHES TO UNITS BELOW MAINS TO BE TAKEN FROM BOTTOM OF MAINS AT A 45 DEGREE 0 2. FLEXIBLE AIR DUCT SHALL BE ATTACHED PER DETAILS, FLEXIBLE AIR DUCT MAY ONLY BE USED •. ANGLE, PITCH DOWNWARD TOWARD UNITS. BRANCHES TO UNITS ABOVE MAINS TO BE TAKEN SPEC. AND SEQUENCE OF SUBMIT Droving No. IN VERTICAL APPLICATIONS WITHOUT PRIOR APPROVAL FROM TENANT'S PROJECT MANAGER UNLESS FROM TOP OF MAINS AT A 45 DEGREE ANGLE PITCHED UPWARD TOWARDS UNITS. PITCH NOT COMPLETED FORM R NOTED OTHERWISE. „ OPERATION. 1 LESS THAN 1" TO 10 FEET. MECHANICAL 3. FLEXIBLE DUCT SHALL NOT EXTEND OVER 5'-0"» IN LENGTH AT ANY ONE LOCATION. C. SEE MECHANICAL DETAIL DRAWINGS FOR APPLICABLE DETAILS. WITH BALANCE REPORT SPECIFICATIONS NTS v MECHANICAL SPECIFICATIONS .. 1 k M5 . 2