Loading...
Specifications (4) I t, ; ■ V ATRIOT FireP� t S i t p�.�IY AT an d Y I 4708 NE Minnehaha Street It � Rk� Slav e/ Vancouver, WA 98661 FIRE PROTECTION, INC. Ape 4, c Date Plans I p I ICI TEL (360) 699.4403 W V .t I TUN 1 2005 PORTLAND (503) 222.6001 699.4 ^ppR° " F n �j, �� \; r i .� J FAX (360) 699.4485 1NC1,U E T10'•1 g 0(� t,CIF I I . i At, Cpd,,.. EQUIPMENT SUBMITT . TTY OF TIGARD } STR� CH R t.P WASHINGTON SQUARE DING DI E u M AY 2 0 200 f \5C i TIGARD, OR PFP Job # 31 -0860 ITEM MANF. MODEL SIZE COMMENTS ' SPRINKLERS *** — - - -- - - ' STANDARD SPRAY UPRIGHT RELIABLE G 1/2" BRONZE 165' & 21 ~ • � STANDARD SPRAY PENDENT RELIABLE G 1/2' BRONZE 165' & 212' — j3r STANDARD SPRAY SIDEWALL RELIABLE G 1/2" BRONZE 165' & 212' ( OJ4 Q R UPRIGHT SPRINKLERS RELIABLE Fl FR 1/2" BRONZE 155' �- — - 1.47 ekr i EXTENDENDED COV. UPRIGHT TYCO EC -11 .6" CHROME 155' & 200 G. EXTENDENDED CON. PENDENT TYCO EC -11 .6" CHROME 155' ' �' P +, ; 2 X 005 u/ I *** VALVES *** ii ,;,r I BUTTERFLY VALVE GLOBAL BV -G 1 WI TAMPER SWITCH .... • ALARM VALVE RELIABLE E 4 "& 6" . DRY VALVE RELIABLE A 2 1/2" „ DOUBLE DETECTER CHECK AMES 3000SS 8” WITH TAMPERS =' FIRE DEPT. CONNECTION P- ROEMER 5721 4x2 1/2 2 -WAY 90 DEG 1 FIRE DEPT. CONNECTION P- ROEMER 5710 4x2 1/2 2 -WAY WALL MOUNT t FIRE HOSE VALVES P- ROEMER 4065 21/2" ON STANDPIPES CO SWING CHECK VALVES RELIABLE G 4" GRVx GRV ( , J AIR MAINTENANCE DEVICE RELIABLE A -2 1" GARAGE DRY SYSTEMS ._ ------ ---'-' *** PIPE *** GROOVED END PIPE MULTALLOY SCH 10 8" STAINLESS GROOVED END PIPE SPS FLOW PIPE 1 114 " - 4^ BLACK ,;. GROOVED END PIPE FIRELINE SCH 10 6" &8" BLACK '"` DLR Group GROOVED END PIPE FIRELINE SCH 10 ALL GALVA r !t'f It ' , DSYS.) SCREWED PIPE FIRELINE SCH 40 1" - 2" BLACK • • EVIEWE INFORMATION REQUIRED **" FITTINGS *** GROOVED COUPLINGS INTERFIT DI 1 1/4 "-8" FURNISH PS CORRECTED GROOVED FITTINGS INTERFIT DI 1 1/4 "-8" Reviewer does not authorize change- to contract stun unless stated to SCREWED FITTINGS SMITH - COOPER DI 1" - 2 separate letter er change order. ❑REVISE AND RESUCMIT 0 REJECTED *** ELECTRICAL DEVICES ""* , This review is cniy for genord confcrmarce will e :e de_ rn cer. : • ' AIR COMPRESSOR GAST 2LAF 11T - M200X 150 GAL 1/4h 11 P, V,QiL;T, given in Lr: Cr.; . ...., . _....... Cc _.. _ -. , OS &Y TAMPER SWITCH POTTER OSY - ON DDC e on the Shcn 5. /:i:1,, du:ir.� s i1 :-r.c.i 1) nc: r_.... .. . PRESSURE SWITCH POTTER PS - 10A from compaance wish file r lir h de s cf iitc c:a and s- :.:.. Review e: a s, disc hero ca: irciu r : cf is a r serr` , cf LOW AIR ALARM POTTER PS - 40A the item is a component. The Con;;. ::c::r iI res; er _ible for:dimarsiu:is t,. tie confirmed and correlated as the jea sac; informet:on that per2i s sole`, to RISER MANIFOLD GRINNELL 513 4 " &6" the fabrication presses cr to the men:, medi•:ods, txhnigees, sequences ELECTRIC BELL POTTER PBD126 6" 110 VOL and procedures of censtcucticn; cm-di:. aca of tae k with that of of other trade and ming ail Work in a safe and satin :acto:y m y ner *** HANGERS * " J for- ' DAT U RING HANGER GRINNELL FIG 69 ALL BEAM CLAMPS GRINNELL FIG. 92 1/2" & 3/8" W/ RETAINER STRAP EARTHQUAKE BRACING TOLCO FIG. 909 ALL BRACE ATTACHMENT EARTHQUAKE BRACING TOLCO FIG. 825 ALL BEAM ATTACHMENT EARTHQUAKE BRACING TOLCO FIG. 980 ALL BRACE ATTACHMENT EARTHQUAKE BRACING TOLCO FIG. 1001 ALL PIPE CLAMP EARTHQUAKE BRACING TOLCO FIG. 4A ALL PIPE CLAMP CONCRETE EXPANSION BOLT HILTI KWIK 11 1/2" & 3/8" NON PT APPLICATIONS THREADED ROD ANCHOR TOLCO FIG. ZE605 3/8" ARM -OVERS CONCRETE INSERT & NUT GRINNELL FIG.281 1/2" EQ. BRACING IN GARAGE 1'„ RISER CLAMP GRINNELL FIG. 261 DROP IN ANCHOR HILTI HDI -P 3/8" UP TO 4" I *** MISCELLANEOUS *** i kr FIRE CAUKING HILTI FS -ONE AS- REQUIRED TACOMA, WA OFFICE HANFORD, WA OFFICE SPOKANE, WA OFFICE TEL: (253) 926.2290 TEL (509) 373.8895 TEL: (509) 926.3428 FAX: (253) 922.6150 FAX (509) 373.8919 FAX: (509) 926.3708 PATRIFPO99CF ,as Bulletin 110 Rev.S INIIMINSINIElliganalla Model G `4,. ® ° Automatic Sprinklers co , w .r Spray Upright j x "` ' ° ` Spray Pendent a And Conventional DJ CD cn Product Description The Reliable Model G Automatic Sprinkler utilizes the center strut solder in compression principle of `<a �K =: w > construction. The fusible alloy is captured in the ::-,.. �.�: -, cylinder of the solder capsule by a stainless steel ball. ;; When the fusible alloy melts, the ball moves into the ? . cylinder allowing the cylinder to fall away from the ?)' . sprinkler. When this happens, the lever is released to . .: r `.. ` spring free from the sprinkler so that all of the operating e4'` parts clear from the waterway allowing the deflector to ;:;' distribute the discharging water. >„„�. ` '"' "' Except for the parts in the cylinder as mentioned 4 above, the sprinkler components are made from Upright Pendent copper based alloys for maximum corrosion - protection. Lead plated, wax coated or wax over lead y : k plated sprinklers are available for specially severe environments. Chrome plated sprinklers are available ' 3 for decorative purposes. WI ' ?' All sprinklers are individually hydrostatically tested. : f ig All sprinklers are identified as to their fusing point by fit' ' '�`' markings that appear on several of the operating parts t; x • and b an identifying color that appears on the frame. . "`-` ry , r y PP h ,. Sprinkler Types Standard Upright – This deflector configuration is Small Orifice Upright Conventional normally used with exposed piping installations. Water is distributed laterally and downward in a wide pattern approximating a hemisphere which is completely and uniformly filled with water in the form of small drops or spray. Standard Pendent – This deflector configuration is Application and Installation normally used where the space above the piping is Standard sprinklers are used in fixed fire protection limited or where a concealed piping installation is systems: Wet, Dry, Deluge or Preaction. Care must be employed. The discharge characteristics of the exercised that the orifice sizes, temperature ratings, standard pendent are virtually identical to the deflector styles and sprinkler spacings are in standard upright as described above. accordance with the latest published standards of the National Fire Protection Association or the approving Large and Small Orifice —By varying the orifice size, authority having jurisdiction. a large or small orifice sprinkler is created that will The sprinklers must be installed with the Reliable distribute as much as 40% more water or 65% less Model D Sprinkler Wrench. Any other type of wrench water than the normal 1/2" (15mm) orifice sprinkler. may damage the sprinkler. The approvals or listings of Reliable Automatic Conventional —This deflector configuration is used Sprinklers by major approving organizations are primarily in those countries where the LPC installation shown in the tabulated list provided on the back of this rules have precedence. The sprinkler is designed to bulletin. distribute a portion of its water discharge upward against the ceiling with the balance downward. It may be installed in either the upright or the pendent position. Sprinklers with conventional deflectors are available with orifice sizes corresponding to light, Patent No. 4,440,234 :, ordinary and extra –high hazard installations. ' The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Technical Data "K" Factor Sprinkler Identification `' Sprinkler Number (SIN) Sprinkler Type US Metric Height Approvals SSU SSP Standard - Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position Y2 (15 mm) Standard Orifice with y2" NPT (R)2) Thread 5.62 81.0 2'''A" (73 mm) 1, 2, 3, 4, 5, 6, 7 R1025 R1015 '% (11 mm) Small Orifice with ,(" NPT (RV Thread 4.24 61.0 2' /e" (73 mm) 1, 3, 7 R1023 R1013 %" (10 mm) Small Orifice with }2" NPT (R)/ Thread 2.82 40.6 2'''A" (73 mm) 1, 2, 3, 7 R1021 R1011 %fi (8 mm) Small Orifice with ,t " NPT (Ry) Thread 1.98 28.5 2' /e" (73 mm) 1, 3, 7 R1022 R1012 1 %2" (20 mm) Large Orifice with , " NPT (Ry) Thread 7.96 114.7 2' /e" (73 mm) 1, 2, 3, 7 R1026 R1016 1 % (20 mm) Large Orifice with %" NPT (R%)Thread 8.20 118.2 2 %" (75 mm) 1, 2, 3, 7 R1027 R1017 20 mm XHH with 20 mm Thread 8.20 118.2 75.4 mm 4, 5, 6 R1027 R1017 10 mm XLH with 10 mm Thread 4.10 59.1 73 mm 4, 5, 6 R1024 R1014 Conventional--Installed in Upright or Pendent Position 10mm XLH with 10mm Thread 4.10 59.1 73 mm 5 81074 15mm Standard Orifice with (8/ Thread 5.62 81.0 73 mm 4, 5, 6 R1075 20mm XHH with (R %) Thread 8.20 118.2 75.4 mm 4, 5 R1077 Temperature Ratings Maintenance Maximum Model G Sprinklers should be inspected quarterly and the Sprinkler Ambient sprinkler system maintained in accordance with NFPA 25. Do Rating Temperature Frame (1) not clean sprinklers with soap and water, ammonia or any other Classification °F °C °F °C Color cleaning fluids. Remove any sprinkler that has been painted Ordinary 135 57 100 38 Black (other than factory applied) or damaged in any way. A stock of Ordinary 165 74 100 38 Uncolored spare sprinklers should be maintained to allow quick replace - Intermediate 212 100 150 66 White ment of damaged or operated sprinklers. Prior to installation, High 286 141 225 107 Blue sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to (1) Frame color does not apply to painted or plated sprinklers sprinklers that would cause improper operation or -Use sprinkler rating as identified on operating parts. non-operation. Use only the Model D Sprinkler Wrench for sprinkler removal and installation. Any other type of wrench may damage the sprinkler. • Finishes Standard Finishes • Approval Organizations Bronze —All Temperature Ratings 1. Underwriters Laboratories, I nc. Chrome —All Temperature Ratings 2. Factory Mutual Research Corporation White (2 —All Temperature Ratings 3. Underwriters' Laboratories of Canada Only Frame and Deflector are Painted 4. Loss Prevention Council Special Application Finishes 5. Pleniere Assemblee 6. VdS Schadenverhutung Bright Brass Plated —Only frame, deflector and cap are plated. 135 °F (57 °C), 165 °F 7 N.Y.C. BS&A No. 587 -75 -SA or (74 °C), 212 °F (100 °C) Temp. Rating. N.Y.C. MEA 258 -93 -E Black Plated —Only frame, deflector and cap are plated. All Temp. Ratings. Polyester Coated (2) —Only frame and deflector are coated. Lead Plated —165 °F (74 °C), 212 °F (100 °C) and 286 °F (141°C) Temp. Ratings. Ordering Information Wax- Coated (3) —165 °F (74 °C) Clear Wax, 212 °F (100 °C) Brown Wax. Specify Wax- Coated Over 1. Model G Lead Plated (3) —165 °F (74 °C) Clear Wax, 212 °F (100 °C) Brown Wax. 2. Deflector • Upright ( Other colors and finishes are available. Consult factory for details. • Pendent ( UL listed and NYC MEA Approved only. • Conventional ( 212 °F (100 °C) brown wax may be used on 286 °F (141 °C) 3. Nominal Orifice sprinklers when maximum ambient temperatures do not exceed 150 °F 4. Inlet Thread (66 °C). UL Listed, FM Approved, NYC MEA 258 -93 -E. 5. Temperature Rating 6. Finish The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by ,. ,..•, , , o•' The Reliable Automatic Sprinkler Co, Inc. (800) 431 -1588 Rellabld (800) 848-6051 Sales Offices Sales Fax (914) 668 - 3470 Corporate Offices Revision lines indicate updated or new data. 'f=ri AgR :- pa_t^r( 0;'7 'ir.Vici i_..rf"., rA_.:...,..,n, l'irl,re `y„ reliahles rinkier.com I nternet Address p EG. Printed in U.S.A. 11/04 P/N 9999970005 • Bulletin 112V nactiMMENSMEIMMINIEMMIIIME G7 • .r liable® Model G Sidewall Model G/F1 Recessed 1 Sidewall Sprinklers A Complete Line of Sidewall Sprinklers , . � + ,� - 1. Model G Vertical Sidewall-Upright. 2. Model G Vertical Sidewall- Pendent. l „ ,„r .: " + }� 3. Model G Sidewall -HSW1 �' Deflector. _ 1 . .r" 4. Model G /F1 /HSW1 Recessed Horizontal Model G Horizontal-HSW1 Sidewall -HSW1 Deflector. " ,:yr� 5. Model G Extended Coverage Horizontal "' Sidewall -EC4 Deflector. , .£" 6. Model G /F1 /EC4 Recessed Extended. _ ' _ '' . Model G — ` "� � CoverageHorizontalSidewall EC4Deflector. VerticalUpright `" f •. `_ " ° — 7. Variety of finishes. 8. Multiple orifice sizes. Model G Horizontal Extended Coverage -EC4 Product Description - t � . Aide • z,� All Reliable Model G Automatic Sidewall Sprinklers uti- ' a g - lize the center strut in compression principle of con- 8g struction. The fusible alloy, retained in the cylinder of a N ''. , small solder capsule by a stainless steel ball, acts as the trigger of the sprinkler. When the fusible al loymelts, Model G /F1 /EC4 Model G /F1 /HSW1 the sprinklersoperat ing parts spring freefrom the sprin- RecessedHorizontal Recessed kler, clearing the waterway and allowing the sprin klerto Extended Coverage —EC4 Horizontal -HSW1 distribute the discharging water. Sidewall Sprinkler Types: Model G /F1 /HSW1 Recessed Horizontal Sidewall Model G Vertical Sidewall Sprinkler Sprinkler -HSW1 Deflector The Model G Vertical Sidewall Sprinkler is designed for The combination of the Model Fl Recessed Escutch- use in light hazard situations where standard sprinklers eon and the Model G Horizontal Sidewall Sprin- are deemed impractical because of decorative or kler HSW1 Deflector provides a very attractive structural conditions. It discharges approximately 15% recessed sprin klerforuse in light hazardoc cupancies. of the water on the wall be hind it with the remain ing 85% Model G Extended Coverage Horizontal Sidewall discharged in front of the sprinkler. This sprinkler may Sprinkler -EC4 Deflector be installed in either the Upright or the Pendent posi- The Model G Extended Cover age Sprin kler is listed for tion. the protection of larger than normal areas in light haz- Model G Horizontal Sidewall Sprinkler— and occupancies. HSW1 Deflector Model G /F1 /EC4 Recessed Extended Coverage This deflector configuration is designed and listed for Horizontal Sidewall Sprinkler -EC4 Deflector use in either light or ordi nary hazard occu pancies. The The combination of the Model Fl Recessed Escutch- use of the Model G HorizontalSidewallSprinklerinordi- eon and the 17 32" (20mm) orifice x 3 A" NPT (R Model G nary hazard occupancies will provide installation sim- Horizontal Sidewall Sprinkler -EC4 Deflector provides a r• plicities and economies in many circumstances. very attractive recessed sprinkler for use in larger than normal areas in light hazard occupancies. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York, 10552 Model G Extended Coverage Horizontal Sidewall Sprinkler - EC4 Deflector Technical Data Approval Type: Length: Extended Coverage -Light Hazard ,, 3%6" (84mm) - Y" (15mm) Orifice Sprinkler O rovalsy I p it ' ° k .. ,;,/ 3 " 32 " 90mm -'i32 "' 20mm Orifices rinkler n ! „,.. ( ) ( ) p Underwriters Laboratories Inc. ,; , ` A Rating: 135 °F (57 °C) NYC BS&A No 587 -75 -SA r Underwriters' Laboratories of �` ' I� Max. Ambient Temp. 100 °F (38 °C) Canada Installation Wrench: Model D Sprinkler Wrench. Color Identification: Technical Data Black Paint (Bronze Finish Only). KFactor Sprinkler Ceiling to Deflector Distance: Coverage Area (dent. 9 Nominal Thread Flow Rate Pressure Width x Length Number 6 to 12 inches (152mm to 305mm). Orifice Size US Metric gpm (L /min) psi (bar) ft. x ft. (m x m) (SIN) ' /2" (15mm) y " (R1) 5.62 81.0 30 (113.5) 28.5 (2,0) 16 x 18 (4.9 x 5.5) R1265 Y2" (15mm) ' /z° (R'/) 5.62 81.0 38 (143.8) 45.7 (3,2) 16 x 20 (4.9 x 6.0) R1265 "32" (20mm) 3 " (R 8.20 118.2 30 (113.5) 13.4 (0,9) 16 x 18 (4.9 x 5.5) R1267 " 32 " (20mm) % " (R /) 8.20 118.2 32 (121.1) 15.2 (1,0) 16 x 20 (4.9 x 6.0) R1267 " 3; (20mm) X " (R 8.20 118.2 37 (140.0) 20.0 (1,4) 16 x 22 (4.9 x 6.7) R1267 17 32" (20mm) 3 " (R /4) 8.20 118.2 39 (147.6) 22.6 (1,6) 16 x 24 (4.9 x 7.3) R1267 Model G /F1 /EC4 Extended Coverage Horizontal Sidewall Sprinkler - EC4 Deflector Technical Data Approval Type: 7 Nominal Orifice: "/ 32 " (20mm) Extended Coverage -Light Hazard ' Thread Size: %" NPT (R3A) Occupancy. , K Fact or: 8.20US (1.18.2 Metric) Approvals: r. Length: 3'%2' (90mm ) Underwriters Laboratories Inc. Rating: 135 °F (57 °C) NYC BS &A No 587 -75 -SA � ` Max. Ambient Temp.: 100 °F (38 °C) Underwriters' Laboratories of Canada Installation Wrench: Model GFR1 Sprinkler Wrench. Color Identification: Technical Data Black Paint (Bronze Finish Only). Deflector to Coverage Area Ceiling Dimension Flow Rate Pressure • Width x Length Min.- Max. Sprinklerldent. gpm (L /min) psi (bar) ft. x ft. (m x m) in. (mm) Number(SIN) 30 (113.5) 13.4 (0,9) 16 x 18 (4.9 x 4.9) 6 - 12 (152 - 305) 32 (121.1) 15.2 (1,0) 16x20 (4.9x6.0) 6 -12 (152 -305) R1267 37 (140.0) 20.0 (1,4) 16 x 22 (4.9 x 6.7) 6 -12 (152 -305) Model G /F1 /EC4 - ° Model G /F1 /HSW1 r-- RecessedSidewallSprinkler r_ , 7 MI .447 .mweu T - , W r' J �� J • • ( 11 41 k r, I � m 1 4-...,, I 2. MODEL G HORIZONTAL SIDEWALL SPRINKLER — HSW1 Deflector Installation Wrench: Model D Sprinkler Wrench. Ceiling . : .,, 4 to6 deflector Inches (102mm to 152mm). .r 1 3 ; ,5 ::;_4� , 4 ip tir s, a Technical Data K Factor Approval Organizations Nominal Sprinkler Sprinklerldentification Orifice Thread Size U.S. Metric Length Light Hazard Ordinary Hazard Number(SIN) '/2" (15mm) Y2" NPT (R' /2) 5.62 81.0 3 (84mm) 1,2,3,5.6 1,3,5,6 R1235 /.- ( 11mm) ' /2" NPT (R1) 4.24 61.0 35i 6 (84mm) 1, 3, 5, 6 — R1233 N"'" (10mm) Y2" NPT (R1/2) 2.82 40.6 3 (84mm) 1, 3, 5, 6 — R1231 ' (20mm) 3 /4" NPT (R /4) 8.20 118.2 35i6' (84mm) 1, 3, 5, 6 R1237 17/ " (20mm) 1/2" NPT (R1/2) 7.96 114.7 35/6' (84mm) 1, 3, 5, 6 — R1236 'Identified by pintle extending beyond deflector. Model G /F1 /HSW1 Recessed Horizontal Sidewall Sprinkler— HSW1 Deflector Rating: 135 °F (57 °C) Approvals: -, Max. Ambient Temp.: 100 °F (38 °C) Underwriters Laboratories Inc. Length: 3)i " (84mm) NYC BS &A No. 587 -75 -SA (s Approval Type: Light Hazard Occupancy Underwriters' Laboratories of Canada °-..: 7 ,. ; Installation Wrench: �' ,, Model GFR1 Sprinkler Wrench - l ii ` Color Identification: " i Black Paint (Bronze Finish only). . Ceiling to Deflector Distance: • 4 to 6 inches (102mm to 152mm). Technical Data K Factor Sprinkler Nominal Thread Identification Orifice Size U.S Metric Number (SIN) ' /2 (15mm) ' /2" NPT (R'h) 5.62 81.0 R1235 '/,6" (11mm) /2" NPT (R1/2) 4.24 61.0 R1233 (" ldentfied by pintle beyond deflector. MODEL G VERTICAL SIDEWALL SPRINKLER Installation Wrench: Model D Sprinkler Wrench I ,*; Installation Position: I fi Upright or Pendent { Approval Type: 'E= Light Hazard Occupancy ss _ f Ceiling to Deflector Distance: 4 to 6 inches (102mm to 152mm). Wall to Deflector Distance: 4 to 6 inches (102mm to 150 mm). Technical Data K Factor Sprinkler r Nominal Thread Sprinkler Approval Identification Orifice Size U.S. Metric Height Organizations Number (SIN) 'z" 15mm Y2" (R1/2) 5.62 , 81.0 2 /e" (73mm) 2,4 R1285 , 3. Temperature ratings and finishes for Model G Horizontal Sidewall— HSW1 Deflector and Vertical Sidewall Sprinklers Maximum Approval Organizations: Ambient 1. Underwriters Laboratories, Inc. Sprinkler T Frame• 2. Factory Mutual Research Corp. °F °C °F °C Color 3. Underwriters' Laboratories of Canada 135 57 100 38 Black 4. LPCB 165 74 100 38 Uncolored 5. NYC BS &A No. 587 -75 -SA 212 100 150 66 White 6. NYC MEA 258 -93 -E 286 141 225 107 Blue Frame color does not apply to plated or painted sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon Bronze Bronze Chrome Plated Chrome Plated Special Application Finishes Sprinkler Escutcheon Bright Brass `4 Bright Brass Black Plated Black Plated Satin Chrome Satin Chrome Lead Plated - 165 °F (74 °C), 212 °F (100 °C) and 286 °F (141 °C)Ratings Wax Coated - 165 °F (74 °C) Clear Wax, 212 °F (100 °C) Brown Wax"' Wax Over Lead Plated - 165 °F (74 °C) Clear Wax, 212 °F (100 °C) Brown Wax"' (11 Other colors and finishes are available. Consult factory for details. 12) Only frame, deflector and cap are plated. 13) 212 °F (100 °C) brown wax may be used on 286 °F (141 °C) sprinklers when maximum ceiling tern per aturesdonotexceed 150 °F (66 °C). UL Listed only. . • Ordering Information: Specify: 1. Model G or G /F1 2. Recessed (Only G /F1) 3. Deflector • Vertical Sidewall Deflector • Horizontal Sidewall - HSW1 Deflector • Horizontal Sidewall - EC4 Deflector 4. Nominal Orifice 5. Inlet Thread 6. Temperature Rating 7. Sprinkler Finish 8. Escutcheon Finish NOTE: Sprinkler and escutcheon are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. Recycled Re idabil (914) 668 -3470 Corporate Offices Paper (914) 592 -1414 Sales Offices (914) 592 -3676 Fax Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in USA 12/00 P/N999997007 Bulletin 136 Rev ,,,�. . . . x . ®. - o Model Fl FR co Model F1FR Recessed Quick Response CD Sprinklers Model Fl FR Sprinkler Types Standard Upright Standard Pendent ..4 Conventional r e : ,, Vertical Sidewall .,� - . Horizontal Sidewall - HSW 1 Deflector �a Model F1FR Recessed Sprinkler Types t Recessed Pendent ° .- Recessed Horizontal Sidewall a. - HSW 1 Deflector Upright Pendent Listings & Approvals =2 1. Listed by Underwriters Laboratories, Inc. (UL) ° t - -4 2. Listed by Underwriters' Laboratories of Canada (ULC) ., 3. Certified by FM Approvals 4. Loss Prevention Council (LPC, UK) t ,, ' 5. NYC BS &A No. 587-75-SA P! , ,_,- k` i ,, 6. Meets MILS 901C and MIL STD 167-1 ff _ 7. Verband der Schadenversicherer (VdS, Germany) 8. NYC MEA 258-93-E I'_ UL Listing Category '.i Sprinklers, Automatic & Open . . Quick Response Sprinkler V ertical S idewall Conventional • UL Guide Number VNIV Product Description Reliable Models F1FR and F1FR Recessed Sprinklers are ,,, ' ',. quick response sprinklers which combine the durability of a 1 _ :,;, standard sprinkler with the attractive low profile of a decorative `t , ,.. ® spri ...: The Models F1FR and Fl FR Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This Horizontal Sidewall Recessed Pendent quick response enables the Model Fl FR and Fl FR Recessed HSW 1 Deflector sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. Application The glass bulb consists of an accurately controlled amount Quick response sprinklers are used in fixed fire protec- of special fluid hermetically sealed inside a precisely manufac- tion systems: Wet, Dry, Deluge or Preaction. Care must be tured glass capsule. This glass bulb is specially constructed to exercised that the orifice size, temperature rating, deflector provide fast thermal response. The balance of parts are made style and sprinkler type are in accordance with the latest of brass, copper and beryllium nickel. published standards of the National Fire Protection Asso- At normal temperatures, the glass bulb contains the fluid ciation or the approving Authority Having Jurisdiction. in both the liquid and vapor phases. The vapor phase can Quick response sprinklers are intended for installation as be seen as a small bubble. As heat is applied, the liquid ex- specified in NFPA 13. Quick response sprinklers and stan- pands, forcing the bubble smaller and smaller as the liquid dard response sprinklers should not be intermixed. pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, ' opening the waterway and allowing the deflector to distrib- ute the discharging water. The temperature rating of the sprinkler is identified by the color of the glass bulb. The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Model Fl FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Sprinkler Type K Factor Sprinkler Identification Standard - Upright (SSU) and Pendent (SSP) S Approval Number (SIN) Deflectors Marked to Indicate Position US Metric Height Organization SSU SSP / (15mm) Standard Orifice with y" NPT (R/2) Thread 5.6 80 2.2" (56mm) 1,2,3,4,5,6,7 R3625 R3615 '%2' (20mm) Large Orifice with /" NPT (R 8.0 115 2.3" (58mm) 1,2,3,4,7,8 R3622 R3612 '/ (17mm) Small Orifice with /2" NPT (RX) Thread 4.2 60 2.54" (65mm) 1,2,8 R3623 R3613 %" (10mm) Small Orifice with /2" NPT (Ry) Thread 2.8 40 2.54" (65mm) 1,2,8 R3621 R3611 10mm Orifice XLH with R%" Thread 4.2 60 56.1mm 4,6,7 R3624 R3614 Conventional - Install in Upright or Pendent Position 10mm Orifice XLH with R% Thread 4.2 60 56.1mm — R3674 15mm Standard Orifice with / NPT (R/2) Thread 5.6 80 56.1mm 4,6,7 R3675 20mm Large Orifice with 3 /4" NPT (R /4)Thread 8.0 115 58.4mm 4,7 R3672 tt � i. . I Vii{ ft q , { _ � ..� Vt fir;" t ',:.:11: .. ,'.. Upright Pendent Upright Conventional Model Fl FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model RC1 Sprinkler Wrench Inst Data: Nominal Thread K Factor Sprinkler Approval Sprinkler Identification Orifice Size US Metric Height Organizations Number (SIN) /2" (15mm) y" NPT (R1/2) 5.6 80 2.2" (56mm) 1,2,3,4,5,7,8 R3615 ' %2' (20mm) %" NPT (R 8.0 115 2.3" (58mm) 1,2,3 R3612 /6' (11 mm) /2 NPT (R'h) 4.2 60 2.54" (65mm) 1,2,8 R3613 %," (10mm) /2" NPT (RY /) 2.8 40 2.54" (65mm) 1,2,8 R3611 10mm R% 4.2 60 56.1mm 4,7 R3614 111 Refer to escutcheon data table for approvals and dimensions. 2 I/4' ROtE Du '�— (67s — +_ 1 15/16' DM (A9-2J pan AGAI ESP H _ '- _ r 1 - „1 REDIIC£R RIM/ COLLAR AW/NSF SPRINKLER WRENCH BOSS I - I I I t— FACE fllDNG TO T (1) CE2tivG [ AO.VSIVEM . ar w,/ `I 10 1/B (S.2N ) -n) 1. II 1. 2 27/32 DK (72.2mmJ 1J6 GOOD (I) REFER 70 ESCUTCHEON OVA FABLE FOR APPROVALS AND DIVERSIONS. 2. Model Fl FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: K Factor Approval Sprinkler Identification Nominal Orifice Thread Size Sprinkler Height US Metric Organizations Number (SIN) 1/2" 1 /2" NPT (R1/2) 5.6 80 2.2" (56mm) 1, 2, 3, 6, 8 R3685 15mm 1/2' NPT (R'h) 5.6 80 2.2" (56mm) 4 (1) (1) LPC Approval is for Pendent position only. r Orientation Deflector to Ceiling r - Dimension (Min. - Max.) ? . ,, Upright 4" - 12" (102mm - 305mm) Pendent 6" - 12" (152mm - 305mm) e. L s 4 zr Vertical Sidewall Model Fl FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: Approval Organizations Sprinkler K Factor and Type of Approval Identification Nominal Thread Sprinkler Light Ordinary Number Orifice Size US Metric Length Hazard Hazard (SIN) X" (15mm) / NPT(R1/2) 5.6 80 2.63" (67mm) 1,2,3,5,8 1,2,5,8 R3635 NOTE: UL and ULC Listing permits use with Fl or F2 recessed escutcheon e,,,;, ligNA ._ - Horizontal Sidewall 3. Installation Sprinkler Types Quick response sprinklers are intended for installation Standard Upright as specified in NFPA 13. Quick response sprinklers and Standard Pendent standard response sprinklers should not be intermixed. Conventional The Model F1FR Recessed Quick Response Sprinklers are to be installed as shown. The Model Fl or F2 Escutch- Sidewall (Vertical, Horizontal HSW1) eons illustrated are the only recessed escutcheons to be Recessed Pendent used with the Model Fl FR Sprinklers. The use of any other Recessed Horizontal Sidewall HSW1 recessed escutcheon will void all approvals and negate all warranties. When installing Model Fl FR Sprinklers, use the Model D Sprinkler Wrench. When installing Model Fl FR Recessed Finishes (" (2) Sidewail Sprinklers, use the Model GFR1 Sprinkler Standard Finishes Wrench. Use the Model RC1 Wrench for installing Fl FR Sprinkler Escutcheon Recessed Pendent Sprinklers. Any other type of wrench Bronze Brass may damage these sprinklers. chrome Plated Chrome Plated (3) White Polyester Coated White Painted (3) Temperature Ratings Special Application Finishes Sprinkler Sprinkler Escutcheon Classification Temperature Max. Ambient Bulb Bright Brass Bright Brass °C °F Temp. Color Black Plated Black Plated Ordinary 57 135 100°F(38 °C) Orange Black Paint Black Paint Ordinary 68 155 lcCrF(38°C) Red Off White Off White Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green Satin Chrome Satin Chrome High (1) 141 286 225 °F(107 °C) Blue ( Other finishes and colors are available on special order. (t) Consult the factory for details. Not available for recessed sprinklers. ( FM Approvals is limited to bronze and brass, chrome or black plated finishes only. Escutcheon Data ( FP Push- on/Thread -off escutcheon t Face of Fitting Escutcheon Model Approvals Adjustment Dimension to Ceiling or Wall Dimension . • Fl • 1,2;4 .% - X" . Y6 ° - • • 'Ordering .Information (19mm) (19mm) • (5mm -24mm) Specify: F2 1,2,3,4,5,7,8 yl, 1" /6' -1X6" 1. Sprinkler Model (13mm) (25mm) (5mm -17mm) 2. Sprinkler Type FP 1,2 Fully Recessed X51 3. Orifice Size Push-on/ (1 1 mm) Thread -off 1,2 Fully Retracted 1$161 4. Deflector Type (24mm) 5. Temperature Rating Maintenance 6. Sprinkler Finish The Models F1FR and F1FR Recessed Sprinklers 7. Escutcheon Type should be inspected quarterly and the sprinkler system 8. Escutcheon Finish (where applicable) maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other Note: When Model F1FR Recessed sprinklers are cleaning fluids. Remove dust by using a soft brush or gen- ordered, the sprinklers and escutcheons are packaged tie vacuuming. Remove any sprinkler which has been separately. painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained I in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non - operation. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries. f, Manufactured by • • The Reliable Automatic Sprinkler Co., Inc. ® Recycled 'e (800)431 -1588 Sales Offices e I iab (800)848 Sales Fax Revision lines indicate updated or new data (914)668 -3470 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 3/03 P/N9999970027 t., CO Fire & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series EC -11 & EC -14 — 11.2 and 14.0 K- factor Extended Coverage (Light and Ordinary Hazard) Upright, Pendent, and Rec. Pendent Sprinklers Corrosion resistant coatings, where - G eneral applicable, are utilized to extend the life of copper alloy sprinklers beyond Description that which would otherwise be ob ,, § tamed when exposed to corrosive at- �` .. '" The Series EC -11 and EC -14 Ex- mospheres. Although corrosion resis - ; ,' 4 + tended Coverage Upright and Pendent tant coated sprinklers have passed the ,, ,,` t Sprinklers are decorative glass bulb standard corrosion tests of the appli ����� �� � ,< sprinklers designed for use in light or cable approval agencies, the testing is ,�,. ' ordinary hazard occupancies. They not representative of all possible cor- f .' are intended for use in automatic rosive atmospheres. Consequently, it �� sprinkler systems designed in accord- is recommended that the end user be te �► ' • . v . ance with standard installation rules consulted with respect to the suitability Ar. � r .a * f ,f,Y ( e. g., NFPA 13 ) for a maximum cover- corrosion a resistant coatings these age area of 400 ft (37,2 m as corn- for any given iven corrosive environment. pared to the maximum coverage area The effects of ambient temperature, of 130 ft (12,1 m for standard cover -. concentration of chemicals, and age sprinklers used in ordinary haz- gas /chemical velocity, should be con - and occupancies or 225 ft (20,6 m sidered, as a minimum, along with the for standard coverage sprinklers used corrosive nature of the chemical to in light hazard occupancies. which the sprinklers will be exposed. The Series EC -11 and EC -14 Sprin- klers feature a UL and C -UL Listing WARNINGS that permits their use with unob The Series EC-11 a n d EC 14 Ex- 4 � - . . . . structed or non-combustible ob tended Coverage Sprinklers des * , ;T , herein must be installed and main '' structed ceiling construction as de- fined and permitted by NFPA 13, as tained in compliance with this docu .,,� v r - ment, as well as with the applicable well as a specific application listing for standards of the National Fire Protec- . ,-` use under concrete tees. lion Association, in addition to the ti F The Series EC -11 and EC -14 Ex- standards of any other authorities hay- tended Coverage Sprinklers have ing jurisdiction. Failure to do so may been fire tested to compare their per- impair the performance of these de- formance to that of standard coverage vices. ®� spray sprinklers. These tests have Model /Sprinkler The owner is responsible for maintain - shown that the protection provided is equal to or more effective than stand- ing their fire protection system and de- Identification and coverage spray sprinklers. vices in proper operating condition. The installing contractor or sprinkler Number manufacturer should be contacted with any questions. TY5137 - Upright, 11.2K IMPORTANT TY5237 - Pendent, 11.2K Always refer to Technical Data TY6137 - Upright, 14.0K Sheet TFP700 for the `INSTALLER TY6237 - Pendent,14.0K WARNING" that provides cautions TY5137 is a redesignation for C5137, with respect to handling and instal- lation of sprinkler systems and com- G1894, and S2510. ponents. Improper handling and in- TY5237 is a redesignation for C5237, ,, stallation can permanently damage G1893, and S2511. a sprinkler system or its compo- TY6137 is a redesignation for C6137, nents and cause the sprinkler to fail G1896, and S2610. to operate in a fire situation or cause it to operate prematurely. TY6237 is a redesignation for C6237, G1895, and S2611. Page 1 of 8 SEPTEMBER, 2004 TFP220 Page 2 of 8 TFP22O a WRENCH 3/4" ** ESCUTCHEON PLATE FLAT NPT SEATING SURFACE 1 1 - Frame - 2 - Button ri ree- — -,�, �i 3 - Sealing Assembly 4 - Bulb 2 5 - Compression Screw INE / 6 - Deflector 2-7/16" I ill I `- :1, 3 • A (61,9 mm) Temperature rating is U PRIGHT & indicated on deflector PENDENT f 1 -11/16" / 4 " Pipe thread %ITO (42,7 mm) \ / connections per ISO ;. 5 7/1 can be provided a on special request. • - -- - - -•• = i� c - 1/2" (12,7 mm) J 6* NOMINAL MAKE -IN CROSS UPRIGHT PENDENT SECTION FIGURE 1 SERIES EC -11 AND EC -14 EXTENDED COVERAGE SPRINKLERS 11.2 K- FACTOR (TY5137) UPRIGHT AND (TY5237) PENDENT 14.0 K- FACTOR (TY6137) UPRIGHT AND (TY6237) PENDENT SPRINKLER FINISH (See Note 5) HAZARD TYPE TEMP. BULB NATURAL CHROME WHITE* LEAD LIQUID BRASS PLATED POLYESTER COATED 135"F/57°C Orange UPRIGHT 155 °F /68 °C Red 1, 2, 3 * * 4 . LIGHT K =11.2 (TY5137) PENDENT 175 °F /79 °C • Yellow . K =11.2 (TY5237) 200 °F /93 °C Green 1, 2, 4 1, 2, 4 Refer to Table B for K =14.0 (TY6237) UL and C -UL 286 °F /141 °C Blue Sensitivity Rating 135"F/57°C Orange and REC. PENDENT 155 °F /68 °C Red 1, 2, 3, 4 Refer to Table C for K =11.2 (TY5237) N/A FM K =14.0 (TY6237) 175 °F /79 °C Yellow Sensitivity Rating With Style 30 1, 2, 4 Escutcheon 200 °F /93 °C Green 286 °F /141 °C Blue UPRIGHT 135 °F /57 °C Orange K =11.2 (TY5137) 155 °F /68 °C Red 1, 2, 3, 4 ORDINARY K =14.0 (TY6137) 1, 2, 3, 4 — and 175 °F /79 °C Yellow Refer to Table B for PENDENT 200 °F /93 °C Green 1, 2, 4 UL and C -UL K =11.2 (TY5237) Sensitivity Rating K =14.0 (TY6237) 286 °F /141 °C Blue and REC. PENDENT 135 °F /57 °C Orange Refer to Table C for K =11.2 (TY5237) 155 °F /68 °C Red FM K =14.0 (TY6237) 1, 2, 4 N/A Sensitivity Rating With Style 40 175 °F /79 °C Yellow Escutcheon 200 °F /93 °C Green NOTES: 1.Listed by Underwriters Laboratories, Inc. (UL). 2.Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the City of New York under MEA 177 -03 -E. 5. Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. 'Frame and Deflector only. Listings and approvals apply to color (Special Order). " Pendent Only. N /A: Not Available ' TABLE A, LABORATORY LISTINGS AND APPROVALS TFP22O Page 3 of 8 P LIGHT HAZARD ORDINARY HAZARD 135 °F 155 °F 175 °F 200 °F 286 °F 135 °F 155 °F 175 °F 200 °F 286 °F AREA STYLE 14 x 14 Up. or Pend. — — — — — SR SR SR SR SR 14 x 14 Style 30 Recessed — — — — — SR SR SR SR N/A 14 x 14 Style 40 Recessed — — — — — SR SR SR SR N/A 16 x 16 Up. or Pend. QR* QR* QR* QR* QR* SR SR SR SR SR 16 x 16 Style 30 Recessed OR QR* OR* QR* QR* SR SR SR SR N/A 16 x 16 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR N/A 18 x 18 Up. or Pend. QR* QR* QR* QR* QR* SR SR SR SR SR 18 x 18 Style 30 Recessed QR* QR* QR* QR* QR* SR SR SR SR N/A 18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR N/A 20 x 20 Up. or Pend. QR* QR* QR* SR* SR* SR SR SR SR SR 20 x 20 Style 30 Recessed QR* SR* QR* SR* SR* SR SR SR SR N/A 20 x 20 Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR N/A OR: Quick Response SR: Standard Response N /A: Not Applicable • Does not apply to Upright K = 14.0 TABLE B SENSITIVITY RATING FOR UL AND C -UL LISTING OF SERIES EC -11 OR EC -14 SPRINKLERS (SEE TABLE D FOR PERMITTED K- FACTOR /AREA COMBINATIONS) LIGHT HAZARD ORDINARY HAZARD 135 °F 155 °F 175 °F 200 °F 286 °F 135 °F 155 °F 175 °F 200 °F 286 °F AREA STYLE 14 x 14 Up. or Pend. — — — — — SR SR SR SR SR 14 x 14 Style 30 Recessed — — — N/A N/A N/A N/A N/A 14 x 14 Style 40 Recessed — — — — — N/A N/A N/A N/A N/A 16 x 16 Up. or Pend. QR• QR* N/A N/A N/A SR SR SR SR SR 16 x 16 Style 30 Recessed QR QR N/A N/A N/A N/A N/A N/A N/A N/A 16 x 16 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 18 x 18 Up. or Pend. QR* QR* N/A N/A N/A SR SR SR SR SR 18 x 18 Style 30 Recessed QR QR N/A N/A N/A N/A N/A N/A N/A N/A 18 x 18 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 20 x 20 Up. or Pend. QR* QR* N/A N/A N/A SR SR SR SR SR 20 x 20 Style 30 Recessed QR QR N/A N/A N/A N/A N/A N/A N/A N/A 20 x 20 Style 40 Recessed N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A QR: Quick Response SR: Standard Response N /A: Not Applicable • Pendent Only TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC -11 OR EC -14 SPRINKLERS (SEE FM LOSS PREVENTION DATA SHEET 2 -8N FOR PERMITTED K- FACTOR /AREA COMBINATIONS) t. Page 4 of 8 TFP220 r ample: obstructions to sprinkler dis- T'echnica® Design charge, obstructions to sprinkler pattern development, obstructions Data Criteria to prevent sprinkler discharge from reaching hazard, clearance to stor- Approvals The Series EC -11 and EC -14 Ex- age, etc. UL and C -UL Listed. FM Approved. tended Coverage Sprinklers must only (Refer to Table A for complete approval be installed in accordance with the ap- UL and C -UL Specific Application information including corrosion resis- plicable UL and C -UL Listing or FM Listing Requirements For tent status. The approvals apply to the Approval requirements as indicated Installation Under Concrete Tees service conditions indicated in the De- below. Only the Style 30 or 40 Re- The Series EC -11 and EC -14 Ex- sign Criteria section.) cessed Escutcheon is to be used for tended Coverage Upright and Pendent Maximum Working Pressure recessed installation, as applicable Sprinklers (TY5137, TY5237, TY6137 175 psi (12,1 bar) (Ref. Table A, B, and C). & TY6237) have a UL and C -UL Spe- UL and C -UL Listing cific Application Listing for use under Pipe Thread Connection Requirements concrete tees when installed as fol- 3/4 inch NPT lows: Discharge Coefficients 1. The Series EC -11 and EC -14 Sprin- K = 11.2 GPM /psi kiers may be used for the coverage 1. The stems of the concrete tee con - (161,3 LPM /bar / areas shown in Table D, based on struction must spaced at fess than K = 14.0 GPM /psi maintaining the minimum specified 7.5 feet (2,3 m) on center but more (201,6 LPM /barli flow rate as a function of coverage than 3 feet (0,9 m) on center. The area and hazard group for all of the depth of the concrete tees must not Temperature Ratings exceed 30 inches (762 mm). The 135 °F /57 °C to 286 °F /141 °C sprinklers in the design area. maximum permitted concrete tee Finish 2. The Series EC -11 and EC -14 Sprin- length is 32 feet (9,8 m); however, Sprinkler: Refer to Table A klers are permitted to be used with where the concrete tee length ex Recessed Escutcheon: White Coated, unobstructed or non - combustible ceeds 32 feet (9,8 m), non combus Chrome Plated, and Brass Plated obstructed ceiling construction as tible baffles, equal in height to the defined and permitted by NFPA 13. depth of the tees, can be installed so Physical Characteristics For example: that the space between the tees Frame Bronze does not exceed 32 feet (9,8 m) in Button . . ... . . ... . . . . Bronze Unobstructed, combustible or non -- length. . Sealing Assembly combustible, ceiling construction Beryllium Nickel w/Teflont with a deflector to ceiling/roof deck 2. The sprinkler deflectors are to be Bulb Glass (3 mm dia.) distance of 1 to 12 inches (25 to 300 located in a horizontal plane at or Compression Screw mm). above 1 inch (25,4 mm) below the Bronze bottom of the concrete tee stems. Deflector Brass Obstructed, non - combustible, ceil- ing construction with a deflector lo- 3. When the sprinkler deflectors are cation below structural members of located higher than a horizontal Patents 1 to 6 inches (25 to 150 mm) and a plane 1 inch (251,4 mm) beneath the U.S.A. Patent Numbers 5,366,022; maximum deflector to ceiling /roof bottom of the concrete tee stems, 5,579,846; 5,584,344; 5,609,211; deck distance of 22 inches (550 the obstruction to sprinkler dis- 5,862,994; and 5,865,256. mm) charge criteria requirements of NFPA 13 for extended coverage up- O eration 3. The Series EC -11 and EC -14 Sprin- right sprinklers applies. kiers having been specifically tested The lass bulb contains a fluid which and listed for non - combustible ob- FM Approval g structed construction are permitted Requirements expands when exposed to heat. When The Series EC -11 and EC -14 Ex- the rated temperature is reached, the to be used within trusses or bar joists tended Coverage Sprinklers are to be fluid expands sufficiently to shatter the having non - combustible web mem installed in accordance with the appli glass bulb, which then allows the sprin- bers greater than 1 inch (25.4 mm) cable Factory Mutual Loss Prevention kler to activate and flow water. when applying the 4 times obstruc- tion criteria rule defined under "Ob Data Sheet for limited use in buildings structions to Sprinkler Discharge of specific roof construction and for the Pattern Development ". protection of certain specific ordinary hazard (non- storage and /or non -flam- 4. The minimum allowable spacing be- mable or combustible liquid) occupan- tween the Series EC -11 and EC -14 cies. Information provided in the FM Sprinklers, to prevent cold solder Loss Prevention Data Sheets relate to, ing, is 8 feet (2,4 m) for upright sprin- but are not limited to, hydraulic design, kiers and 9 feet (2,7 m) for pendent ceiling slope and obstructions, mini - sprinklers. mum and maximum allowable spac- ing, and deflector -to ceiling distance. 5. The Series EC -11 and EC -14 Sprin- These criteria may differ from UL klers are to be installed in accord- and /or NFPA criteria, therefore the de- ance with all other requirements of signer should review and become fa- NFPA 13 for extended coverage up- miliar with Factory Mutual require - right and pendent sprinklers. For ex- ments before proceeding with design. TFP22O Page 5 of 8 r 2 -7/8" DIA. "FITTING SIDE" _ 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) TOWARDS SPRINKLER (12,7 ±3,2 mm) 2 -1/4" DIA. _ 1/4" (6,4 mm) FITTING FACE OF (57,2 mm) SPRINKLER 1/8 r FITTING (3,2 mm) �+'' ��riii = Ix WRENCH _ _ RECESS 1 \ ���M , t , (END "A") 1 MOUNTING 111 I SURFACE MOUNTING FIGURE 4 PLATE W - TYPE 3 SPRINKLER CLOSURE ki# , WRENCH 1 -3/8" (34,9 mm) WRENCH RECESS i:!i► 1 -1/8" (28,6 mm) FIGURE 2 SERIES EC -11 AND EC -14 RECESSED PENDENT SPRINKLER ASSEMBLY r � o, Kw " WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT I�i STYLE 30 RECESSED ESCUTCHEON • 100 0 s � a0 f _ 2 -7/8" DIA. J _ 5/8 ±1/4" (73,0 mm) 3/4" (19,1 mm) 1 I M (15,9 ±6,4 mm) 2 -1/4" DIA. _ 1/4" (6,4 mm) W HEX FACE OF (57,2 mm) FIGURE 5 SPRINKLER 1/8" W -TYPE 22 RECESSED FITTING (3,2 mm) SPRINKLER WRENCH I , --___,--, IL i 7 _ i f \ ■ j f MOUNTING 41 MOUNTING SURFACE II PLATE CLOSURE 1-3/8" (34,9 mm) . 7/8" (22,2 mm) FIGURE 3 SERIES EC -11 AND EC -14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON Page 6 of 8 TFP22O A GROUP I GROUP II LIGHT HAZARD ORDINARY HAZARD ORDINARY HAZARD 0.10 GPM /FT 0.15 GPM /FT 0.20 GPM /FT DESCRIPTION AREA GPM PSI GPM PSI GPM PSI TY5137 (K =11.2) UPRIGHT 14 x 14 - - 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 18 x 18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 TY5237 (K =11.2) PENDENT 14 x 14 - - 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 18 x 18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 TY6137 (K =14.0) UPRIGHT 14 x 14 N/A N/A - - - - 16 x 16 N/A N/A 39 7.8 51 13.3 18 x 18 N/A N/A 49 12.3 65 21.6 20 x 20 N/A N/A 60 18.4 80 32.7 TY6237 (K =14.0) PENDENT 14 x 14 - - - - - - 16 x 16 37 7.0 39 7.8 51 13.3 18 x 18 37 7.0 49 12.3 65 21.6 20 x 20 40 8.2 60 18.4 80 32.7 1 ft. = 0.3048 m 1 ft = 0.093 m 1 gpm = 3.785 Ipm 1 psi = 0.06895 bar 1 gpm /ft = 40.74 mm /min T ABLE D FLOW CRITERIA FOR UL AND C -UL LISTING OF SERIES EC -11 AND EC -14 SPRINKLERS Installation Step 1. The sprinkler must be installed p with the deflector parallel to the mount- ing surface. Pendent sprinklers must The Series EC -11 and EC -14 Sprin- be installed in the pendent position, klers must be installed in accordance and upright sprinklers must be in- with the following instructions: stalled in the upright position. NOTES Step 2. After installing the Style 30 or Do not install any bulb type sprinkler if 40 mounting plate (or other escutch- the bulb is cracked or there is a loss of eon, as applicable) over the sprinkler liquid from the bulb. With the sprinkler pipe threads and with pipe thread held horizontally, a small air bubble sealant applied to the pipe threads, should be present. The diameter of the hand tighten the sprinkler into the air bubble is approximately 1/16 inch sprinkler fitting. (1,6 mm) for the 135 °F /57 °C to 3/32 Step 3. Wrench tighten upright or pen - inch (2,4 mm) for the 286 °F /141 °C dent sprinklers using only the W -Type temperature ratings. 3 (End A) Sprinkler Wrench. Wrench A leak tight 3/4 inch NPT sprinkler joint tighten the recessed pendent sprin- should be obtained with a torque of 10 klers using only the W -Type 22 Sprin- to 20 ft.lbs. (13,4 to 26,8 Nm). A maxi- kler Wrench. The wrench recess of the mum of 30 ft.lbs. (40.7 Nm) of torque applicable sprinkler wrench (Ref. Fig - is to be used to install sprinklers. ure 4 and 5) is to be applied to the Higher levels of torque may distort the sprinkler wrench flats (Ref. Figure 1). sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over - tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. TFP22O Page 7 of 8 and stalling contractor or sprinkler menu- Care and ®i1 �9eted facturer should be contacted relative to Maintenance any questions Warranty It is recommended that automatic The Series EC -11 and EC -14 Sprin- sprinkler systems be inspected, Products manufactured by Tyco Fire klers must be maintained and serviced tested, and maintained by a qualified Products are warranted solely to the in accordance with the following in- Inspection Service in accordance with original Buyer for ten (10) years structions: local requirements and /or national against defects • in material and work - codes. manship when paid for and properly NOTE installed and maintained under normal Before closing a fire protection system use and service. This warranty will ex- main control valve for maintenance pire ten (10) years from date of ship - work on the fire protection system that ment by Tyco Fire Products. No war- it controls, permission to shut down the ranty is given for products or affected fire protection systems must components manufactured by compa- be obtained from the proper authori- nies not affiliated by ownership with ties and all personnel who may be Tyco Fire Products or for products and affected by this action must be notified. components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, Sprinklers that are found to be leaking maintained, modified or repaired in ac- or exhibiting visible signs of corrosion cordance with applicable Standards of must be replaced. the National Fire Protection Associa- Automatic sprinklers must never be tion, and /or the standards of any other Authorities plated, coated, or otherwise rials found by Tyco Fire Products Having Mate - efe ectLivve found defective after leaving the factory. Modi- h ll ir or at T yco o Fire sprinklers must be replaced. d either repaired Sprinklers that have been exposed to replaced, at Tyco Products' sole corrosive products of combustion, but option. Tyco Fire Products neither as- sumes, nor authorizes any person to have not operated, should be replaced assume for i other if they cannot be completely cleaned with any the sale of products in connection by wiping the sprinkler with a cloth or pa w • by brushing it with a soft bristle brush. • parts p Products t responsible Tyco Fire P Pr d shall of not be du for sprinkler Care must be exercised to avoid dam- system design errors or inaccurate or age to the sprinklers - before, during, incomplete information supplied by and after installation. Sprinklers dam- Buyer or Buyer's representatives. aged by dropping, striking, wrench IN NO EVENT SHALL TYCO FIRE twist/slippage, or the like, must be re- PRODUCTS BE LIABLE, IN CON - placed. Also, replace any sprinkler that TRACT, TORT, STRICT LIABILITY OR has a cracked bulb or that has lost UNDER ANY OTHER LEGAL THE - liquid from its bulb. (Ref. Installation ORY, FOR INCIDENTAL, INDIRECT, Section). SPECIAL OR CONSEQUENTIAL Frequent visual inspections are rec- DAMAGES, INCLUDING BUT NOT ommended to be initially performed for LIMITED TO LABOR CHARGES, RE- corrosion resistant coated sprinklers, GARDLESS OF WHETHER TYCO after the installation has been com- FIRE PRODUCTS WAS INFORMED pleted, to verify the integrity of the cor- ABOUT THE POSSIBILITY OF SUCH rosion resistant coating. Thereafter, DAMAGES, AND IN NO EVENT annual inspections per NFPA 25 SHALL TYCO FIRE PRODUCTS' LI- should suffice; however, instead of in- ABILITY EXCEED AN AMOUNT specting from the floor level, a random EQUAL TO THE SALES PRICE. sampling of close -up visual inspec- THE FOREGOING WARRANTY IS Lions should be made, so as to better MADE IN LIEU OF ANY AND ALL determine the exact sprinkler condi- OTHER WARRANTIES EXPRESS OR tion and the long term integrity of the IMPLIED. INCLUDING WARRANTIES corrosion resistant coating, as it may OF MERCHANTABILITY AND FIT - be affected by the corrosive conditions NESS FOR A PARTICULAR PUR- present. POSE. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- • Page 8 of 8 TFP22O Ordering P/N 51 - AAA - B -CCC Procedure AAA = 893 (for TY5237 When placing an order, indicate the full K11.2 Pendent) product name. Please specify the AAA = 894 (for TY5137 Sprinkler Identification Number (SIN), K11.2 Upright) quantity, and temperature rating. Refer AAA = 895 (for TY6237 to the Price List for complete listing of K14.0 Pendent) Part Numbers. AAA = 896 (for TY6137 Contact your local distributor for avail- K14.0 Upright) ability. Sprinkler Assemblies with NPT B = 1 (for Natural Brass) Thread Connections: B = 3 (for White [RAL9010])* Specify: (specify SIN), (specify K -Fac- B = 4 (for White Polyester) tor), (specify temperature rating), B = 7 (for Lead Coated (specify Pendent or Upright) Extended B = 9 (for Chrome Plated) Coverage Sprinkler with (specify fin- ish), P/N (specify - from Table E, where applicable). CCC = 135 (for 135 °F /57 °C) CCC = 155 (for 155 °F /68 °C) Recessed Escutcheon: CCC = 175 (for 175 °F /79 °C) Specify: Style (specify 30 or 40) Re CCC = 200 (for 200 °F /93 °C) cessed Escutcheon with (specify fin- ish), P/N (specify). Style 30 Recessed Escutcheon `Eastern Hemisphere sales only. Chrome Plated PSN 56- 705 -9 -011 TABLE E White Color Coated PSN 56- 705 -4 -011 White (RAL9010)• PSN 56- 705 -3 -011 PART NUMBERS FOR Brass Plated PSN 56- 705 -2 -011 EC -11 AND EC -14 SPRINKLERS • Style 40 Recessed Escutcheon • Chrome Plated PSN 56- 700 -9 -010 • White Color Coated PSN 56- 700 -4 -010 White (RAL9010)* PSN 56- 700 -3 -010 Brass Plated PSN 56- 700 -2 -010 'Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W -Type 3 Sprinkler Wrench, P/N 56- 895 -1 -001 Specify: W -Type 22 Recessed Sprin- kler Wrench, P/N 56- 665 -7 -001 TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 , Z .: . c � J - , '.� � �"` �� is � t .9. °.� �.t�� d ,�� ira�ti,., a • r m .. - ` _r: 4.,.7d.. - PRODUCT INFORMATION UL & ULC Listed. FM Approved. Model : BB - G (Bronze Butterfly Valve Grooved Type) Specifications Size : 2" Through 2 -1/2" Working Press. : 175 psi • Max. Test Press.: 350 psi Working. Temp. : 250F (120 C) Factory Installed UL Approved Tamper Switch. for "Indoor use only Material Body : Brass, Bronze Disc : Brass, Ductile Iron. EPDM Encapsulated. Stem : Stainless Steel Model : BB - T (Bronze Butterfly Valve Threaded Type) Specifications Size : 1" Through 2 -1/2" Working Press. : 175 psi Max. Test Press. : 350 psi z .- Working Temp. : 250F (120 C) Factory Installed UL Approved Tamper Switch. for Indoor use only Material Body : Brass, Bronze Disc : Brass, Ductile Iron, , 1 4 410 EPDM Encapsulated. Stem : Stainless Steel r GS .g ". , 'i . .. s f` �. �, � n rt � x, 3! 7 } �i s r t � n ,ts.ea.. 7 •� TECHNICAL DATA Dimension (SCH 40, C =120) Grooved End (2 -1/2" Through 8" ) p.-- ,- —+ a unu no iIissuu•o . a III n II c ma - "' M AL z•s/s I L 6-7/8 Wafer Style (2 -1/2" Through 8" ) D_ all II H _ i it J •!�` '_` ellit 1 ` aI g oNW I :► 2.5/8! 6-7/8 L I Dimension, Weight and Equivalent Length (SCH 40, C =120) SIZE OPERATOR "L", "C" "H1 "OPERATOR - 1" PIPING "D" APP. STYLE PIPE O.D. C.L TO TOP RANGE P.C.D C.L TO RIGHT TAKE -OUT HANDWHEELD WEIGHT IN. IN. IN. IN. IN. IN. IN. lbs. 2 - 1/2 2 -7/8 I 9 -7/8 - 5 -3/8 3 -3/4 5 I 18.6 3 3 -1/2 10 -1/8 I - 5 -3/8 3 -3/-1 5 19.7 4 GROOVED 4 -1/2 11 -1/2 - 5 - 3/8 I 4 - 1/2 5 23.6 6 6 -5/8 12 -7/8 I - 7 -5/8 5 -1/-1 9 34.1 8 8 -5 /8 I 13 -3/4 I - 7 -5/8 5 -3/4 9 44.9 2 - 1/2 - I 9 -1/8 15 -1/2 5 -3/8 I 1 -3/4 + 5 I 19.1 ;, 3 - 9 -1/8 6 1 5 -3/8 1 - 3/4 5 20.1 4 WAFER - 10 -3/4 7 -1/2 5 -3/8 I 2 5 21.7 t. 6 - I 12 -1/8 9 -1/2 I 7-3/8 1 2 -1/4 9 25.8 8 - I 13 11 -3/4 1 7 -5/8 1 2 -3/8 9 I 39 . -1 :.- .as a .;. .!¢:;�ia1f: 44":,...: � tv� .i 4:;.-;::4%:.• � p� -7%, . �,;;(��+`. . '''':.$14:648 4; Ili . ( ",t: -, - i —„,} ' + ' , ' _ �b� . ' • , ti 3. Switch Wirion Diagram(When Valve Full Open Position). S -L OPEN(RED) FIRE ALARM END OF LINE CONTROL PANEL COMMON(WHITE) CLOSED(YELLOW) RESISTOR E SUPERVISORY � NEXT DEVICE CIRCUIT (GREEN) ACTUATOR CASE GROUND Ci) S -2 OPEN(ORANGE) COMMON q CLOSED(BLUE) :'AUX. DEVICE • a: VOLTAGE (BLACK) I (BELL OR HORN) :' r SOURCE NOTES 1. RATED : 5A- 1/6HP- 125/250V AC 0.5A -125V DC 0.25 -250V DC Switch # 1 S1 : For connection to the supervisory circuit or. a UL Listed \ alarm control panel. : Normally Closed (2) Yellow : Normally Open (2) Red : Common (1) White Switch # 2 S2 : Auxiliary switch which may be connected per authority having jurisdiction to auxiliary device : Normally Closed (1) Blue : Normally Open (1) Orange : Common (1) Black Housing Found lead #14 AWG is provided (1) Green. Distributed By : GLOBAL SAFETY PRODUCTS, INC. 970 E. ORANGETHORPE AVE UNIT # B ANAHEIM, CA 92801 TEL : 714- 525 -2262 FAX : 714- 525 -2138 TECHNICAL DATA Dimension (SCH 40, C =120) Grooved End (2" Through 2 -1 /2 ") 85 m 70 110 40.5 70 ` ■ \ �,-- CA � `� . L 7 ! _ _ 1 1J , L__ (Ara low 11 ! 0 LE_ . ..___----__i Threaded Style (1" Through 2 -1/2 ") 110 r V-- ii �5 . I " _ p70 1 _ . , , , ! I � 11 I II Wit _ / ►• EP • I A 4 : Dimension, Weight and Equivalent Length (SCH 40, C =120) AP WEIGHT YLE SIZE "L" IN(mm) "H," IN(mm) "H" IN(mm) "B" IN(mm) "C" IN(mm) "D" IN(mm) "E" IN(mm) LbiH 2.2(1) 1ADED 1" 2.12(54) 1.45(37) 2.0(52) 3.5(1.6) 2.2(1) 1 -1/4" 2.63(67) 1.61(41) 2.2(56) 1 ) 1 -1/2" 2.87(73) 2.41(61.3) 2.32(59) 1 3.9(1.8) 2" 3.24(82.4) 1.92(49) 2.51(64) 1 4.6(2.5) t, 2-1/2" 4.09(104) 2.14(54.5) 2.73(69.5) 1 2.8(1.3) 'OVED 2" 4.48(114) 1.92(49) 3.56(90.5) 2.37(60.3) 2.25(57.1) 0.06(15.8) 0.31(7.9) 2.8(1.3) 2 -1/2" 4.48(114) 2.14(54.5) 1 3.56(90.5) 2.87(73) 2.72(69) 10.078(15.8) 0.31(7.9) Bulletin 417 Rev W model E fleJ ® 4" (100 mm), 6" 150 mm) El and 3 "(200 mm Alarm C heck V alves z wit M E Tri Features g 1. Made expressly for all wet -pipe sprinkler systems * F t _i7 lrc .. - 2. Clappers' groo seat design insures , R , positive w ater flow alarm operation. �= I 3. Precision retard chamber prevents °' I false alarms under variable pressure conditions. `��� 4. External ai prevention of false ' alarms under by -pass all supply ds pressure conditions. �� %. 5. Installation in either I ther vertical or horizonta �� positions. lr .t :E 6. Three connection styles available: "�` ANSI flanged inlet and outlet The Reliable Model E Alarm Check Valve acts as a Water ANSI flanged inlet and grooved outlet Flow Alarm Device in wet pipe sprinkler systems. The de sign allows for installation under both variable and con - Metric flanged inlet and outlet stant suppl pres sure conditions. When water flows in the 7. Pressure trim Styles available: sprinkler sy stem due to t he o peration of one or more Auto- matic Fire Sp rinkler s the Ala Valve opens, allowing con - Individual part trim tinuousf I Pre - assembled trim ala both elec trically an d mechanically. Factory trimmed valve 8. Pressure Relief Trim approved by Factory Mutual Corporation. (FM) Approvals & Listings: � 1. Listed b Underwr Laboratories and mx , certified by UL for Canada (cULus) R < -Ic .-:`,':;:,_,;:i:„ 2. Approved by Factory Mutual , w f� _ , Research co rp. (FM) �k '" 4. NYC BS & A N o. 587- 75-SA. ,',.,.!„,,,,.„‘,t-4' ,' ., 5. Scientific Services Laboratory (SSL, Austraiia) � - , .. Alarm Check Valves; metric gauge 100mm, _�� t; 150mm 200mm. � z.g The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Operation Valve Description Variable Pressure 1. Rated working pressure 175 psi (12,3 bar). The Reliable Model E Alarm Check Valve in its closed and 2. Factory hydrostatic test pressure 350 psi (24,6 bar). open positions is shown in Fig.1 and Fig. 2. The closed 3 End and trim connections —Three valve connection position is maintained as long as the water pressure in the styles are available. sprinkler system piping above the Alarm Valve is greater a. US Standard Flanged Inlet and Outlet than, or equal to, the supply pressure. A flow of water in • Flanges mate with ANSI B 16.1 (125 lb.) Flange the system piping, resulting from the discharge through one or more fused Automatic Sprinkler(s), causes the U.S. Flange Dimensions In Inches (mm) Clapper to rise off its Grooved Seat and permits water Bolt Bolt Flange from the supply to enter the system for distribution on the Valve Circle Hole Outside Flange No. Size Dia. Dia. Dia. Thickness Bolts fire. Virtually all sprinkler systems piping contain confined 4 (100mm) 7,� 3/4 9 15 116 8 6 (150mm) 91/2 7 /8 11 1 8 air. If a water hammer or pressure surge occurs in the 8 (200mm) 114 7 /6 131/2 1 8 supply line, the increased pressure will compress the confined air and cause the Alarm Valve Clapper to lift i •Threaded openings per ANSI B 2.1. termittently which may result in false alarms. The Model E • Reliable's standard trim sets are compatible with Alarm Check Valve prevents false alarms under these • US Flanged Valves. p Color—Black conditions using two features: b. US Standard Flanged Inlet and Grooved Outlet a. The By -Pass connection with Check Valve (Figure 3 & 4) • Inlet flange mates with ANSI B 16.1 (125 lb.) Flange. allows pressure surges from the supply to by -pass the • Outlet groove per ANSI /AWWA C606 Alarm Valve Clapper. An excess system pressure is thus created which steadies the Clapper. Should a U.S. Groove Dimensions In Inches (mm) heavy surge unseat the Clapper and permit water to Valve Outlet Groove Groove Outlet Face flow into the alarm line, the Retard Chamber then co- Size Dia. Dia. Width To Groove mes into action. 4 (100mm) 4.500 (114) 4.334 (110) % (9.5) 5 (16) 6 (150mm) 6.625 (168) 6.455 (168) 7 % / (9.5) (16) b. Drain Orifice Restriction from / to the Retard Chamber al- 8 (200mm) 8.625 (219) 8.441 (214) 7 6 (11.11) y (19) lows intermittent flows to be drained before the Cham- ber fills and activates the Alarms. • Threaded openings per ANSI B 2.1 • Reliable's standard trim sets are compatible with Constant Pressure US Flanged and Grooved Valves. The operation of the Model E Alarm Check Valve in instal - • Color— Black lations where the water pressure is constant, is the same c. Metric Flanged Inlet and Outlet as described above, with this exception: The Retard • 100mm & 150mm valve plain face flanges mate Chamber is not required and water passing through the with DIN2501, NF -E -29 -282, ISO 2084 NP10 and Groove in the Alarm Check Valve Seat flows directly to NP16 and BS4504 NP10 and NP16. and activates the Mechanical and Electrical Alarms. • 200mm valve raised face flanges mate with DIN 2501, ISO 2084 NP16 and BS4504 NP16. Metric Flange Dimensions in Millimeters Note: 1 bar =100 kPa Bolt Bolt Flange Valve Circle Hole Raised Face Outside Flange No. Size Dia. Dia. Dia. Ht. Dia. Thickness Bolts 100mm 180 18.3 — — 229 23.8 8 150mm 241 22.2 — — 279 25.4 8 200mm 295 22.2 268 3 343 28.6 12 Model E Alarm Valve I r , I I- L r r J To System To S tern 11.111M111 %. r ` 0 / WIDE OPEN CLAPPER IN ♦ ♦ ♦♦ ♦ J ♦ POST AON CLOSED POSITION l& Q . ♦♦ �O ii iix, INCII ♦ I/ ,/� � II N. ______--,.,,,a,,, N. GROOVED �� UNCOVE IIII ii. % / / / %y SEAT IIII _ GROOVE SEAT \���� 1 1!111 �..4.: \ L From rely _ _ _ From 72:::_r_;,...:;_zii, I l__ I /�- s 41,201 -e l __ ) c� -e :. Fig. 1 Fig. 2 2. • Threaded openings per BS21 -1957. • Pressure Relief Trim Kit— Required with a wet pipe • • Reliable's standard trim sets may be used with system when a rise in ambient temperature can cause Metric Valves providing trim is assembled care- system pressure to exceed 175 psi (12 bar) or with fully and extra thread sealant is applied to connec- gridded systems. tions between valves and trim. • Color— Blue Pressure relief trim is not intended for use in relieving wa- 4. Face to Face Dimension ter hammer or fire pump surges. It must be installed and • For 4 (100 mm) Model —11 (299 mm) maintained in compliance with NFPA 13, local codes • For 6 (150 mm) Model —131 (343 mm) and the authority having jurisdiction. • For 8 (200 mm) Model —141/2 (368 mm) Trim Kits are available, galvanized or ungalvanized, 5. Shipping Weight (ungalvanized is standard) in three trim styles: Flanged Inlet and Flanged Inlet and • Individual part trim Outlet Grooved Outlet •Pre assembled trim • Factory trimmed valve 4 (100 mm) 80 lb. (36.3 kg) 70 lb. (31.8 kg) 6 (150 mm) 116 lb. (52.6 kg) 102 lb. (46.3 kg) r,. F - 8 (200 mm) 155 lb. (70.3 kg) 143 lb. (64.9 kg) RETARD 6. Friction Loss — Expressed in Equivalent Length of Pipe, "" i i Based on Hazen & Williams formula with C = 120. � \ I) ` "'! i j i ,, Eauiv Length .. L ,, « 4 (100 mm) 17 (5.18 m) ri,,�( .,.. ' - V#4 KIT) 6 (150 mm) 27 (8.23 m) � � `! K � ii r - ` Y, uooe. 8 (200 mm) 29 (8.84 m) ^ o = ,,4 ,•. - i� i 7. Installation position —All sizes may be installed either R. , j i 1` i vons vertically or horizontally. i ,, Y� =VµVE l r - r - " - .. Z_ L. -_.- �..J Model E3 Trim Description i i i •w.,E The E3 trim sets for the Reliable Model E Alarm Valve (Figs. 3 i .,r i W & 4) are arranged for rapid, easy and compact attachment, i U i and serve as connection points to Reliable alarm and other ""GOO-` ® devices. They also act as a means for testing the system to cppw operate. The Model E alarm valves are available in two trims `°"'°""` K ?' and may be installed in the vertical or horizontal position in Fig. 3 the main supply to the wet pipe system: Alarm valves are listed and approved by Underwriters • Constant. Pressure, Closed Drain - Retard Chamber is Laboratories, Inc: and Factory Mutual Research Corp. not required. The Model E3 trim comes as a constant only when used with the valve manufacturer's trim sets. pressure trim. This trim set is used where water supply Ordering Information— Specify: pressure does not vary, such as a gravity tank. • Valve Size -4 (100mm), 6 (150mm) or 8 (200mm). mechanical sprinkler alarm line automatically drains to When size is specified in mm, a metric valve per 3.c will the 2 (50mm) main drain line. be supplied. • Variable Pressure with Closed Retard Chamber Drain— • Inlet and Outlet Connection — Either Flanged /Flanged Retard Chamber is required. This trim is used where or Flanged /Grooved. water supply pressures vary. An open Drip Cup is •Type of Trim — Constant Pressure or Variable provided to drain the Retard Chamber and the Pressure /Open Drain or Variable Pressure /Closed Mechanical Sprinkler Alarm line. This drain connection Drain. should be piped separately from the 2° main drain. • Variable Pressure with Open Retard Chamber Drain — 'Style of Trim — Individual Part Trim or Pre Assembled • Additional Equipment— Retard Chamber, Mechanical Retard chamber is required. Sprinkler Alarm, Pressure Relief Trim Kit, and Pressure Optional Drain Line Kit required (see Figs. 3 & 4). Alarm Switch must be separately ordered. This trim set is used where water supply pressures vary. An open drip cup is provided to drain the re - RELft ADM tard chamber and the mechanical sprinkler alarm < <� . I line. This drain connection should be piped sepa- r:;:: +`:+��� rately from the 2 main drain. r -:_ ./ ..n-•. - tee ." i i t 44;‘' % " , I ckwu Y,, a Note: 1 ,IW i A ; , • The tri permits both vertical (Fig. 3) and ! II i ".. y . --- - -- - - horizontal (Fig. 4) installations. <- _ ' �"°� • A TestANDrain valve segment is optional, to I 1 . ! _ _ i 0 be purchased separetly, as a replacement - J ns, i Brass i 1 to the Drain valve see o tional Kit in Fi s. 3 (1.1AN K"' 1 OWETALK I �:, ( p 9 /n m rx, �PKRO o) I b 1 & 4 ). (:iji 5� • All trim sets can be fitted with an optional `°°"°""` K "' Pressure Relief Trim Kit (see optional kit in ; Figs. 3 & 4) to relieve pressures above 175 (OP, Al!) ,�,». • psi in the sprinkler system, as required by Figure 4 NFPA 13, 3 -1.2. 3 • Model E3 Trim Illustrations Vertical & Horizontal _ Installation Measurement in Inches (mm) Valve A _ B C D E F G H I J K L M 4 7 101 161/2 6 16 15 31/2 5 12 41/2 61/2 10 81/4 (100) (178) (267) (419) (152) (426) (381) (89) (146) (305) (114) (165) (254) , (210) _ 6 7% 111/2 171/2 7 15 161/2 414 7 12 41/2 61/2 10 6 (150) (165) (194) (292) (445) (178) (387) (419) (108) (178) (305) (114) (165) (254) (172) 8 7% 111/2 171/2 7 151/4 161/2 414 7 12 4 61 10 6 (200) (194) (292) (445) (178) (387) (419) (108) (178) •(305) (114) (165) _ (254) (172) Vertical Trim, Variable Pressure - Horizontal Trim, Variable Pressure - Front Elevation Front Elevation D f+D -! IN I I. Pik -•- CI --- n n N E TO .. '3' /^ MP SYSTEM - A � f rk , f6 TO 70 SYSTEM ci:71 ":1 FROM .1 ,'V �I -• l ', SUPPLY Dreg a FROM i , G SUPPLY A 9 -^} DRAIN 7 �O7wCS C LINE m F LI DR R A E IN •17VVCT •InAcr Vertical Trim, Variable Pressure - Top View Horizontal Trim, Variable Pressure - Top View / / / // ;^� H J .I I f Q _._._L L K _ M • {I °' 14 - i. 1 ll: L c I ee it , :.1 � -- . - t_ y ll : -- 1 1 -} i H I Y 407VVCT ;'O- 4 07HV VO 477VV T Vertical Trim, Constant Pressure - Horizontal Trim, Constant Pressure - Front Elevation Fron Eleva i.n D N TO SYSTEM A 0 -'- n E 1 i ' -' W A (►/cam �.II TO TE4 _ -_ II ,:�; (, ",111 11 M �1.7.:04..p p ::IIMiliN 1 glu FROM '1 - `s:_�__ 1. tt six., iM w IRA 4% __, r lii 1 an : .,..„, FROM SUPPLY A 2 • B .— A-I DRAIN 2• LINE DRAIN 407VCCT C .07NaF LINE 417VCCF The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances, whenever applicable. Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. ® Receded Paper r, � ® (800) 431 -1588 Sales Offices Reliabld (800) 848 -6051 Sales Fax (914) 668-3470 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 3/02 P/N 9999970050 Bulletin 352 Rev ® e W . , as, ReilliabP% 2Y2 (65MM) W ®ry Pipe valve ry K k Features 1. Differential type...simple... light- weight construction. �� 9 2. Threaded -in one piece air and water p seat —eases maintenance. � ` < .. =t � 3. Bronze seat with "0" ring seals— n ` , � f ; prevents corrosion and leakage. °N� { 4. Single hinge pin and latch design — s no complicated levers. "f' , A a } is '-, , 1".0 5. Simple to reset —no special tools , required. 6. Tapered air and water seats — induces hairline differential operation. 7. One piece rubber facing — provides more reliable rubber- to-metal water seal. 8. Furnished in 2'/2" NPT, 2'/2" grooved The Reliable Model A Dry Pipe Valve makes possible the installation of automatic sprinkler systems in build ends Or 65mm threads. ings in which freezing temperatures prevail. This type of system, called the dry system, has air under Ares sure instead of water in the piping above the dry pipe L is t in gs & Approvals valve. When one or more automatic sprinklers operate 1. Listed by Underwriters Laborator Inc. (UL) due to fire, the air pressure in the system is reduced, 2. Listed by U Laboratories of Canada. (ULC) the dry pip valve opens and water under pressure 3. Certified by FM Approvals flows to the activated sprinklers) and is then distrib 4. Loss Prevention Council. (LPC, UK) uted on the fire. 5. NYC BS&A No. 587- 75-SA. I 6. Scientific Services Laboratories (SSL, Australia) The Reliable Sprinkler Co., Inc. 525 North MacQuesten Parkway, Moun Verno New York 10552 Operation The Reliable Model A Dry Pipe Valve in its closed and such a small amount of compressed air, even a very tiny open positions is shown in Figures 1 and 2. The closed po- leak could drop the air pressure to a point where the dry sition is maintained as long as the air pressure in the sys- pipe valve would operate. tern pipes above the dry pipe valve is sufficient to exert a The use of an automatic air maintenance device corn - greater force on the top side of the clapper than is exerted pensates for these small leaks and maintains the system on its underside by the pressure of the water supply. Since at a safe pressure. However, it is especially designed to the area included by the air seat is approximately six times not retard the operation of the dry pipe valve when a that of the water seat (The Differential Principle) the air sprinkler does open. pressure needed to keep the dry pipe valve closed is only Reliable's Model A -2 and Model B-1 Automatic Air a fraction of that of the water supply. Table 1 gives the rec- Maintenance Devices are described in greater detail in ommended air pressure for various water supply pres- Bulletin 250. sures for Model A Dry Pipe Valves. . Table 1 Quick Opening Devices Water Pressure Air Pressure The use of a quick opening device is not recom- In Supply Line psi (bar) To Be Pumped Into System psi (bar) mended because of the small size of systems usually as- Maximum Not less than Not more than sociated with a 21" (65mm) dry pipe valve. 20 (1.4) 10 (0.7) 20 (1.4) A slight leak in a small system could cause an acceler- 50 (3.4) 15 (1.0) 25 (1.7) ator to operate thereby operating the dry pipe valve pre - 75 (5.2) 20 (1.4) 30 (2.0) maturely. 100 (6.9) 25 (1.7) 35 (2.4) 125 (8.6) 30 (2.0) 40 (2.7) Valve Description 150 (10.3) 35 (2.4) 45 (3.1) 1. Rated working pressure: 175 psi (12.3 bar) 175 (12.0) 40 (2.8) 50 (3.4) 2. Factory hydrostatic test pressure: 350 psi (24.6 bar) Note: 1 bar = 100 kPa 3. End and trim connections - three valve connection When one or more automatic sprinklers operate due to styles are available: fire, the air pressure in the system pipes above the dry pipe valve is reduced. The pressure of the water supply, a) 21/2 American Standard taper pipe thread inlet now by exerting the greater force, raises and rotates the and outlet. clapper to its open position, permitting the water to flow to • Threads per ANSI B 2.1 the operated sprinkler(s). Water also flows from the alarm • Color - Black . outlet of the dry pipe . valve. through a strainer to the me -. • b) 21" Grooved, inlet and outlet chanical sprinkler alarm and electric alarm switch to auto- per ANSI /AWWA C606 standard. matically actuate mechanical and electrical alarms. • Outlet diameter - 2.875" Reliable Model A Dry Pipe Valves can be reset quickly • Groove diameter - 2.72" and easily without the use of special tools. • Groove width - %" • Outlet face to groove - %" Automatic Air Maintenance Devices • Color - Black The use of an automatic air maintenance device is c) 65mm inlet and outlet strongly recommended with any dry system. It becomes a • Threads per ISO 7/1 -R. necessity when the system is as small as that associated • Color - Blue with a 21" (65mm) valve. Typically, these systems may 4. Friction loss -9.5 ft (2.9m)- Expressed in equivalent have a capacity of only 10 to 25 gallons. In a system with length of Sch. 40 pipe, based Hazen & Williams for- mula with C =120. S ar / Priming / /// /// P ensure `` \�� Inlet I nq j / Priming Woler Level / ° _ CIO/7W j j , � / ... �' - -� Drain Plug J . ' •! `h- = l Water Seat = l ( 1 , � 1/2" NPT .il �_ a. \l Drain �, \ I 1/4 NPT Alarm Outlet / �i�`�1V ��� \'� Alarm Teat J / MIL 1/4" NPT A ' SoDDIY Water Closed ^f Pressure Open • 351/Lar Isrrere 15XG01 Figure 1 Figure 2 2. Trim Description The trims for Reliable Model A Dry Pipe Valves (Figure The trim sets, connections, operation and maintenance 4) are arranged for rapid, easy and compact attachment of the additional items which comprise a dry pipe valve and serve as connection points to alarm and other de- system, such -as air maintenance devices, air compres- vices. They also serve as a means of setting and resetting sors, electric alarm switches and mechanical sprinkler the dry pipe valve prior to and after operation as well as al- alarms are described in Bulletins 250, 275, 608 , and 612. lowing testing of the alarm devices without causing the All valves are listed and approved by Underwriters Lab - system to operate. oratories, Inc. and Factory Mutual Research Corp. only The Model A Basic Trim Set is shown in Figure 4 (the when used with the valve manufacturer's trim sets. electric sprinkler alarm switch and strainer are not part of Ordering Information the trim set and must be ordered separately). This trim set Specify provides the air supply, drain, priming level and alarm . When size is sp Valve eci connections. An alarm test valve, which allows the alarm • Val in millimeters, size imE Either ither 2Yz" or 652 metric valve per 3.c. will be eci devices to be tested without operating the dry pipe valve, lied. is included. The Basic Trim Set includes all items such as outlet connection either threaded/threaded an ball drip valves, pressure gauges, etc. which are needed • Inlet grooved/grooved and o o rooved to enable proper dry pipe valve operation. • Trim—Basic Trim Kit Two additional trim attachments are offered; these are Priming Chamber Attachment the Priming Chamber Attachment and the Fill Line Attach- Fill Line Attachment ment. The Priming Chamber Attachment allows the prim- • Additional equipment —Air maintenance devices, air ing level to be maintained while the system remains compressors, electric sprinkler alarm switches and pressurized. The Fill Line Attachment provides a source mechanical sprinkler alarms must be separately ordered. of water for maintaining the prime level. Installation Dimensions in Inches ■ r 1 f1• fzn41 —t - 1 1)774 r 9• 7. 0i I el • 11728) (6 4 I���'' /_ n� r l241 i 7 - a /a jr -.:. .. . (1 77.8] qr �.�� !187.3) 1 ,4 u 134.81 _ . 1 Mu m .. a ■ .1 !1 i 1 i Iris •.': 7 u p 16• [177.81 N „ !I !406.4) 6. 8 !117.0] (127.0) - 8 . r — 1 20 1 (177.81 MIDI, 12" 1 To toad erticat Electric `xrlder � y 7� / �k c am, a, 4 � J (NOtSt g'" .' - AgCgrriqVebe ta ..,..•• ...-' . e -...*'-z_ '":,,:,": , - ' ' . VaM)■,..., , , , (tttr '�' 4 "1 w m F � � �` -mac ' c #�. y syh d t , y (1:0:1:5!' .. ' .�� 4 t S '- °� N th t �TP "' , - Man DimiVaNe / tt Ted Nam a "� : ..: •i Tel yam Vats Figure 3 Figure 4. Model A Dry Pipe Valve and Trim 3. Reliable..For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Supertrol electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retard chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by • The Reliable Automatic Sprinkler Co., Inc. . Recycled ® ' ® (800) 431 -1588 Sales Offices �" Paper '� (800) 848-6051 Sales Fax (914) 668 Corporate Offices Revision lines indicate updated or new data www.reliablesprinkler.com Internet Address PG. Printed in U.S.A. 2/03 P/N9999970027 " ,,_ a' x } �xr', ES- A- 3000SS U �tA' Y �4 �§ aY 2�+ £ ' tip � s �'" k k. 4 ' Tk �F : ,� pa, 2 �q y f 0 S eries 30 ` , r FIRE &WATERWORKS Double Check � A ssemb li es 4 � , ,K , PilAirlreMakt,ri"..4V03 6 ., .,,,,, a. ,- t m Sizes: 2 - 12 (65 = 300m)k�� ,: gw -`ai g �, �� ° r %, t� � U * + f� 3000SS tt 4 g s °°' s„hx a 3 a„ qfp , - ' �« v 'v . •' i TA• 't Features � ;.+.a �* z v ��- �$ 4t 7 ..rte �'* � g �� �" 'x �r s� x �x t ,. �, �-� �s N -z, � � • Patented Cam Check Assembly valve, �' b , , provides to hhead loss, z 1. g � N , 4 k. ��" , ,:.,5::,€.-..'. � k ' r I ' • Short lay l e ngtFi s'ideally sudedifor _ `; f n v j , fetrpflt installationS� ° � " a `` ''° 9'1' -` a ��>� ,` y +s hal a h a l . v �"�,o 9 ht ` p d k $ v A h u ^" .0 ' . . Vx ,s ue ',4.4 •�8t ' alnlesS s ; ieet`ti a d f the wei }of competitive designs�reducing i t installation shipping,cost ` 4 `. ` " r` , z a _ •t Stainless-steel construction provides ' ^ 4 ,, -a "V aF t a long term corrosion rotection and 4 ', , z" v i ` _ . ,� �z �° (maximum s Series 3000SS Double Check Detec g p . to ` j a Sl n le to tor As are designed for use in accordance /R E g p cover with two -bolt with water utility non - health, hazard containment, requirements. It is mandatory to . -• grooved style ooiipiing for ease of prevent the reverse flow of fire protection system substances, i.e., glycerin wetting maintenance agents, stagnant water and water of non - potable quality from being pumped or • No special tools required for servicing siphoned into the potable water supply. • Compact construction allows for smaller vaults and enclosures Specifications • Furnished with %" x 3/4" bronze meter (gpm or cfm) A Double Check Detector Assembly shall be installed on fire protection systems when • Detects underground leaks and connected to a potable water supply. Degree of hazard present is determined by the unauthorized water use local'authority having jurisdiction. The.main valve body shall be manufactured from • Maybe installed horizontal or vertical 300 Series stainless steel to'provide corrosion resistance, 100% lead free through the "flow up" position waterway. The double check detector assembly consists of two independently operating, spring loaded check valves, two UL, FM, OSY resilient seated gate valves, and bypass Available Models assembly. The bypass assembly consists of a meter (cubic ft. or gallons), a double check including shutoff valves and required test cocks. Each cam -check shall be internally Suffix: loaded and provide a positive drip tight closure against reverse flow. Cam -check LG - less shutoff valves includes a stainless steel cam arm and spring, rubber faced disc and a replaceable OSY - UL/FM outside stem and yoke seat. There shall be no brass or bronze parts used within the cam -check valve resilient seated gate valves assembly. The check valve seats shall be of molded thermoplastic construction. The *OSY FxG - flanged inlet gate connection and use of seat screws as a retention method is prohibited. All internal parts shall be grooved outlet gate connection accessible through a single cover on the valve assembly. The valve cover shall be held 'OSY GxF - grooved inlet gate connection in place through the use of a single grooved style two -bolt coupling. The bypass line and flanged outlet gate connec- shall be hydraulically sized to accurately measure low flow. The bypass line shall con - tion sist of a meter, a small diameter double check assembly with test cocks and isolation *OSY GxG - grooved inlet gate connection and valves. The bypass line double check valve shall have a single access cover, two grooved outlet gate connection independently operating modular poppet check valves, and top mounted test cocks. CFM - cubic feet per minute The assembly shall be an Ames 3000SS. GPM - gallons per minute meter Materials Available with grooved NRS gate valves - consult factory* All internal metal parts: 300 Series stainless steel, Main valve body: 300 Series stainless Post indicator plate and operating nut steel, Check assembly: Noryla Flange dimension in accordance with AWWA Class D. available - consult factory* Noryl® is a registered trademark of General Electric Company. *Consult factory for dimensions Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www. amesfirewater. com • Pressure — Temperature Standards Temperature Range: 33 °F - 1 10°F (5 °C - 43 °C) AWWA C510 -92, UL 1469 . Maximum Working Pressure: 175psi (12.06 bar) Approvals Capacity For 12" approvals consult factory. Flow curves as tested by Underwriters Laboratory per UL 1469, 0 ..ps s 'F /e 1996. * Rated flow **UL Tested O .-zt. Approved C 43 us 1048 (sizes 2'12" - 10 ", (OSY Only) 2'/2" (65mm) OSY Only) • kPa psi * ** ,tpa psi 6" (150mm) * ** 83 12 - - - - 103 15 - - 69 10 83 t2 _ 55 8 62 9 41 6 28 4 41 6 14 2 21 3 0 25 50 100 150 200 250 300 350 400 450 500 525 gpm 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 gpm 95 190 380 570 760 950 1140 1330 1520 1710 1900 1995 Ipm 380 760 1140 1520 1900 2280 2660 3040 3420 3800 4180 4560 4940 5320 5700 Ipm 15 fix 5 10 15 Bps 4.5 fillis 1.5 3 4.8 nips kPa psi 3" (80mm) ** kPa psi 8" (200mm) * *y . 83 12 83 12 _______1111__11 69 10 _______UI__UI_� 62 9 54" 1 6 -.u____ � _oi__. 41 6 ^ 28 4 a-_-____EII- �l.�1 / '� f_' __`�-__�'il-_11 .__ 21 3 14 2 ___1111_—_E MIME= EMI= - — 0 25 50 100 150 200 250 300 350 400 450 500 550 600 gpm 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 gpm 95 190 380 570 760 950 1140 1330 1520 1710 1900 20902280 1pm 950 1900 2850 3800 4750 5700 6650 7600 8550 9500 1p 15 fps 5 10 15 fps 4.6 nips 1.5 3 4.8 mps Id'4 psi 4" (100mm) * ** kPa psi 10" (250mm) * ** 103 15 - 103 15 - 83 12 83 12 62 9 . 4 _ . . . 62 9 �.....444„. 47 fi 41 6 0 0 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 gpm 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 3000 3500 gpm 171 380 570 760 950 1140 1330 1520 1170 1900 2090 2280 2470 26602850 Ipm 950 1900 2850 3800 4750 5700 6650 7600 8550 9500 11400 13300 fpm 5 10 15 fps 5 10 fps 1.5 3 4.6 nips 1.5 3 nips 12" (300mm) - kPa psi 110 16 97 14 II � � 83 12 (�` 69 10 �. 8 goo : (Open) r Q _ __.._ n 070 41 6 I . o o\ 28 4 s o 0 14 2 � o O 0 0 500 1000 1500 2000 080 00 5pm 1 1900 3600 5700 1600 9500 2500 71400 3 13300 35 15200 4000 17 100 Ipm g 0 0 5 10 fps I I_--. L I I P 1.5 3 mps A >5 _ 1; +;... , D IMENSIONS ' e s • ' r = * .. : Y. , NET WEIGHT ':NET WEIGHT} SIZE hNl' �. Y � "' s ',.4." ^!:.:. . � � .., A C (OSY) D G L P w /Gates w/o Gates in. mm in. mm in. mm in. mm in. mm in. mm in. mm lb. kg. lb. kg. 2 65 37 965 16 416 3 89 10 250 22 559 12 318 155 70 68 31 3 80 38 965 18 479 3 95 10 250 22 559 13 330 230 104 70 32 4 100 40 1016 22 578 4 114 10 250 22 559 14 368 240 109 73 33 6 150 48 1232 30 765 5 140 15 381 27 699 15'/2 394 390 177 120 54 8 200 52 1334 37 959 6 171 15 381 29 749 18 464 572 259 180 82 10 250 55'/2 1410 45 1162 8 200 15 381 29 749 19'/2 495 774 351 190 86 12 300 57 1461 53 1349 9 241 15 381 29 749 I 21 533 1044 474 220 100 ... A IMPORTANT: Inquire with governing authorities for local. installation requirements. AM lE S , ISO 9001 FIRE &WATERWORKS A Division of Watts Regulator Company www.amesfirewater.com CERTIFIED 1 42 7 North Market Blvd. • Suite #9 • Sacramento, CA 95834 • Phone: 916- 928 -0123 • Fax: 916 - 928 -9333 ES- A- 3000SS 0513 ©Ames Co. 2005 POTTER- ROEMER " � ` �¢ r 1 , � S ar ,. f A t ; x� � � , ' ' 4 iE XPDSEb FIRE DEPT IN LET " I l CON NECTIONS CLAPPER `TYPE k '; A Division of Smith Industries, Inc. y a ! s , r „-• 5710 TWO -WAY WITH SINGLE CLAPPER Clapper Pin Set Screw `0. , Rearing • Swivel i • '+� J 'Ax' 7 ( i 1 ' 1 N. ., Gasket __; . Single Clapper TWO -WAY WITH SINGLE CLAPPER / FUNCTION: Used as an auxiliary inlet connection, providing 500 GPMns92 /pm minimum (Ref. /L NFPA 14) to supplement the fire protection water supply. Swing clapper provides unobstructed waterway. Exposed design is an economical method of satisfying fire dept inlet requirements. ''/' REGULARLY FURNISHED: Cast brass two -way inlet body, swing clapper and pin lug swivel. Back or angle outlet as selected by model number. Lettering as selected. Size 4 " /1o.2 cm x 2A "x ® ® 2"/6.4 cm x 6.4 cm. OPTIONAL FINISHES: C!:,. - -B Polished Brass *� . 1 i ".: .: O. .: =C Rough Chrome Plated �- 5. -1 p,.... • -D Polished Chrome ■81... - ____ O)3 C© " �' ^ , .:7 LETTERING 6 Plated I s /a' 0. ' a 12.7 cm • AUO R , W 5f'm 1 "L STANDPIPE 10" ___ 1b" __ SPECIFY: Thread 25,4 cm 25 cm :':. 1!, 5715. _ and lettering Model 5710 ... Back Outlet Model 5715 ... Angle Outlet TWO -WAY WITH DOUBLE CLAPPERS / FUNCTION: Used as an auxiliary inlet connection, providing 500 GPM /16921pm minimum (Ref. L / NFPA 14) to supplement the fire protection water supply. Drop clappers provide unobstructed • waterway. Exposed design is an economical method of satisfying fire dept inlet requirements. * � ':'., ''„ REGULARLY FURNISHED: Cast brass two -way inlet body, drop clappers and pin lug swivels. . #�' " Size and outlet as selected by model number. Lettering as selected. OPTIONAL FINISHES: M A c 71/4 m -B Polished Brass 4 `' -C Rough Chrome Plated • . • I I • ` -D Polish Chrome Plated • 5 `,;57: ` e 4 __ D _ LETTERING AVAILABLE: AUTO SPKR Model 5720 Series Model 5730 Series STANDPIPE Back Outlet 90° Angle Outlet SPECIFY: Thread and lettering Outlet . ' • Outlet 1 Locations ' > Locations - 9 ti / Back a A • B C D Angle A 8 C D • b Model Size Z. In. in. in. in. Model Size 271 , in. in. in. In. N0. cm cm cm an N0. cm cm cm cm ,r • k �' - A.'" 5721 4 x 2'h x2'12 YES YES 1 7'/2 - 11 8'12 11'/4 5731 4 x 2'h x2'12 YES YES 7'h 11 872 11' 4 r" 102x6.4 x6.4 19 29.2 21.5_ 28.5 10.2x6.4x6.4 19 29.2 21.5 28.5 5722 6 x 2'4 x 2'h NO NO 9'/= 10'/2 9 10'/• 5732 6 x 2'/= x 2'/2 NO NO 9'h 1O'/2 9 10'/, 15.2x6.4x6.4 24.1 26.6 22. 27.3 15.2x6.4x6.4 24.1 26.6 22.9 27.3 5723 4 x 3 x 3 NO YES 9'/= 11'h 9'h 11 5733 4 x 3 x 3 NO YES 9' /= 11'h 9'/= 11 10.2 x7.6 x7.6 24.1 29.2 27.9 10.2x7.6x7.6 24.1 29.2 24.1 27.9 _ 5`731 57' 5724 15 36x76 YES i NO 25 279 2616 27.9 5734 /5.2x NO NO 25. 279 _ 25.6 27.9 Pape 5 -9 NOTE: ALWAYS INDICATE HOSE THREAD REQUIREMENTS • An dimensinnm in Fnnlich one Licari, u . r : , t POTTER- ROEMER 1: ' ' - { HOSE'' VALV i ; , .- A Division of Smith Industries, Inc. ANGLE ._-. FEMALE x MALE DOUBLE FEMALE FUNCTION: Used with a fire hose rack FUNCTION: Used with a fire hose rack • assembly or as a fire dept outlet connection. assembly. REGULARLY FURNISHED: Cast brass valve REGULARLY FURNISHED: Cast brass valve • -• . • with red handwheel. Female NPT inlet x male with red handwheel. Female NPT inlet and _ �' r hose thread outlet. 300 PSI/2o.6 bars. outlet. 300 PSI /2o.6 bars. w - ;;.• - Model Model t ' ..}:,: -,; ; 4060 1 . cm Size 4070 1 % "/3.8 cm Size i mu, €1.1 4065 ..0<---- 2 '/z " /s.4 cm Size 4075 2V/6.4 cm Size ® SPECIFY: Thread . hread 4060'` 4065 OPTIONAL FINISHES: -B Polished Brass B • -C Rough Chrome Plated . -D Polished Chrome Plated VARIATIONS: • 11%, 11 l T EMI Extended stem u to 24 "/61 cm, SPECIFY: Length IOW OM i� "/3 ill cm petcock SPECIFY: Location. `� +� i C - • Size Appro Open ��I��I Female X Male shown • UL FM A • B.. C C• D E. II Listed ro in. in. in. In. .In. i IIII►� Cm CM CM Cm Cm C m E ; r* 1'/." 2'/. 3'h 6'h 7'/: 272 2 -"' I ® F 3.8cm YES YES 87 8 .9 16.5 19 6.4 5 _300_, l / ` 64 YES YES 8!9 1 2 7 24 29 12 ' 8 '9 , 69 I -AE 4070''&1.'407 ADJUSTABLE PRESSURE RESTRICTING ANGLE VALVE r, _:'i + FEMALE x MALE DOUBLE FEMALE FUNCTION: Used with a fire hose rack FUNCTION: Used with a fire hose rack ,:: - assembly or as a fire dept outlet connection. assembly. Water pressure is controlled by mwat Water pressure is controlled by adjustable flow adjustable flow restriction. If full flow is required, restriction. If full flow is required, the restriction the restriction may be overridden. •',, ;_; may be overridden REGULARLY FURNISHED: Cast brass valve ; u;- .• : ..,, ; REGULARLY FURNISHED: Cast brass valve with red handwheel with pressure restricting i.` ,..;'-'411 8 `' - with red handwheel with pressure restricting feature. Female NPT inlet and outlet. 175 PSI /12 rr�; ,'. feature. Female NPT inlet x male hose thread bars rated. Furnished with field setting chart. outlet. 175 PSI /12 bars rated. Furnished with field Model setting chart. 4090 . , , 1 /"/3.8 cm S ize , , 4 090 . si. . - Model 4095 2', "/6.4 cm Size ' • .•, I - ••• ' • 4080 1 I A" /3.8 cm Size 4085 2 /6.4 cm Size Ei t i a -'1. 4 i; SPECIFY: Thread ••• OPTIONAL FINISHES: --- 'f .i ed Brass = Ji � � �' - B Polished ■ _ ,C, _ - C Rough Chrome Plated :: .,�_ v ® .. -D Polished Chrome Plated 4(97 �` ______. .....„,....,.... ..„_, .., ., . , __ Closed Open t« r,' :1,,p , 'now { Double Female shown �; ;•*:: , : I .,. Size Listed A pps- In. in. In. In. in. I n.. - cm cm cm cm cm cm -178. YES NO 2' /r 3'/' 6'h 7'/, 27' 2 , 175 II 3.8cm 5.7 8.9 16.5 19 6.4 5 - V/P' YES NO 3'/: 5 9 11' /2 3 2'/. I A • 6.4cm 8.9 12.7 24.1 29.2 8.9 . 6.9 . 4090 I ii 4:09 - NOTE: ALWAYS INDICATE HOSE THREAD REQUIREMENTS ' : All dimensions In English and Metric. ,' Page 4-8 • Bulletin 8078 5 ( , l . L s i Model G o .._ .x F�.�' :�.�. k,n:. ' sv. A .t ar . . �., i; aE "rfl+ t r � +' 'i � ,n u.. _ �` % Mx.F 43�x l L t �; 2 1/2" / �.�9 � 3 9 4 & 6 ' YM S y l l id" { Swing Check ~ # Y 1 V .. z 1$�' ,e4 } i'� .. i " ' ' " i i l k S . � ` Valves . .. _ i - The Bight- Check Features 1. Grooved end connections. 2. Compact, lightweight design. a 3. Non- slamming, spring loaded clapper - 6, 1i to minimize water hammer. fir r: ; , 4. Approved for horizontal and vertical ;: 4 k1 installation. ' ' 5. Streamlined body des provides ,`( } ' + very low friction loss. 6. Elastomer faced clapper provides leak -free, non - sticking sealing. 4 • 7. Listed by Underwriters Laboratories, Inc. and Underwriters' Laboratories of Canada. Approved by Factory Mutual Research Corp.* NYC MEA 258 -93 -E Figure 1 Reliable Model G Swing Check Valves are multiple Valve Description purpose valves performing regular check valve duties 1. Rated working pressure 250 psi. with very low friction loss. All four sizes are approved for 2. Factory hydrostatic test pressure 500 psi. use in fire protection systems. Typical applications in- clude connections between public water supplies and 3. Friction loss, expressed in equivalent length of Sch. private fire systems, at the discharge from fire pumps, at 40 pipe with C = 120 (based on Hazen and Williams gravity tank connections and at fire department pumper formula). connectio{is,. 21/2"- 7 ft. 4" - 10 ft. The 4" Model G Check Valve is provided with a 1/2" 3" - 7 ft. 6" - 16 ft. NPT supply side connection (Item 12, Fig.2). This 1/2" 4. Standard grooved end dimensions per ANSI /AWWA NPT supply side connection is optional for all other valve C606. sizes and must be specified. Grooved end connections provide fast and easy 5. Face -to -Face distance L (Fig. 2): installation using listed or approved mechanical 2 - 7.03 in. 4" - 8.44 in. grooved couplings. Rigid style grooved couplings can 3" - 7.62 in 6" - 10.25 in. be used for positive clamping to resist flexural and 6. Shipping weight (including plugs): torsional loads. Right - Check valves and associated equipment 2 - 9 lbs. 4" - 17 lbs. should periodically be given a thorough inspection and 3" - 11 lbs. 6" - 38 lbs. test. NFPA 25 provides minimum maintenance require- ments. Check valves should be inspected and operated at least annually. Parts should be replaced as required. When Model G Swing Check Valves are installed vertically, :the direction of the flow arrow must point FM Approved as both a Single check valve and as an Anti - upward. For horizontal installations, the hinge pin must Water Hammer cheek valve. be located at the top. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, NewYork10552 Part Number Item Part Name Material Quantity 2rirz' 3" 4" 6" No. 1* Valve Body Gray Iron, ASTM -A48 Class 30A _ 1 91005022 91005023 91005024 91005026 2' Seat Bronze C83600 or C93200, ASTM-B505 1 96020200 96020300 96020400 96020600 3 Clapper Stainless Steel 304, ASTM -A240 1 91816112 91816113 91816114 91816116 4 Facing Seal" EPDM Rubber 1 95520200 95520300 95520400 95520600 5 Clamping Ring Stainless Steel 304, ASTM -A240 1 95290300 95290300 95290400 95290600 6 Gasket" EPDM Rubber 1 93720302 93720302 93720604 93720604 7 Spring Stainless Steel 302, ASTM -A313 1 96400300 96400300 96400400 96400600 8 Hinge_Pin . Stainless Steel 303, ASTM -A582 1 95000280 95000300 95006824 95000600 9 Bolt Stainless Steel 304, ASTM -F593 1 91090300 91090300 91090400 91090600 - 10 Locknut " Stainless Steel 303, ASTM -F594 1 94911420 94911420 94913816 94913816 11 Plug, '/a" NPT Steel 1 _ 12 Plug, ' z" NPT Steel _ " Replacement Seal Kit 1 6888040025 6888040030 6888040040 6888040060 I 'Not field replaceable. Valve Disassembly 5•0— MI•,II rAi-NA 1. Close the main water supply valve and drain the a _ ��������,_„ system. . system. z.o - I,/In!�'A 2. Remove the check valve from the piping Inspect the Seat (2) sy o 3. p wrii g„ for any cuts, scrapes and dents. Replace the valve if any damage is found. o = ,= mo=w .... . . t.0 aimmi� ..t =�.�r..a••u �� 4. To replace the Facing Seal (4), remove the Clapper NomemigammAs■u►ammomi (3), unscrew the Locknut (10) and remove the 0.5 WAMMINIV4INI•IE — MN 100 500 1000 2000 3000 retention Bolt (9). Valve Reassembly • 1. Thoroughly clean • the .Clapper (3). Insert the . I L retention Bolt (9) with a new Gasket (6). 0 0 0 2. Place the new Facing Seal (4) and the Clamping Ring (5) against the Clapper (3). Tighten the new / / /����� Locknut (10) to 21 in. lbs. torque in 2 and 3" sizes and to 52 in. lbs. in 4" and 6" sizes. ✓ �j ■ 3. Insert the clapper assembly into the valve through i I�; the downstream opening. Reinsert the Hinge Pin (8) while holding the coils of the properly oriented •• Spring (7) in place. Install the hinge pin Plug (11). _�;. 4. Reinstall the check valve in the system. 21 , 5. Place the system back in service. A 1 t 1 Ordering r� Specify: ' 1. Model G Right -Check Valve. ll 2. Size. lairififi 3. 1/2" NPT optional supply side connection for valve 0 Oar 0 sizes other than 4". Contact the installing contractor or Reliable if any difficulties are O ® © © oPrxawt experienced. Should replacement parts be needed, use only genuine Figure 2 Reliable parts. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association. Factory Mutual Researcn Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. qualified anc Products manufactured and distributed by Reliable have been protecting life and property for over 70 years, and are installed and serviced b y the most highly reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by - ® Printed m U. S.A Recycled Piper The Reliable Automatic Sprinkler Co., Inc. `� II e l e a b t e (800) 431 -1588 Sales Offices (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 668-3470 Corporate Offices PG. Printed in U.S.A. 8/95 Bulletin 250 Rev.I ' x ,1� 4 . �. Vr Models A -2, B -1 & B -2 CO .,, u , Automatic P ressure . ' M ° .. .. - Devices Features 1. Eliminate manual system pressure main- tenance. 2. Prevent accidental dry pipe valve and dry :: : , pilot line deluge valve operation due to ;) 1 4 ( low air pressure. t�'. - 1(E 3. Models suitable for dry nitrogen supply, or ( -\ � � j local tankless compressor. 4. Suitable for preaction system supervision. - ;0 5. May feed duel dry pipe valve systems. l;, 6. Bypass valve incorporated for quick filling 4. system. 7. Shutoff valves permit servicing without Model A -2 shutting down sprinkler protection. 8. Easily adjusted pressure settings. Application Reliable pneumatic pressure maintenance devices i l; • I .,r, are used to automatically maintain the correct pressure s 4.: � in dry pipe valve, or preaction systems, and in dry pilot Lai' lines for deluge systems. When installed in these sys- . 1., 4� {t terns, they eliminate the need for manual filling to over- come small leaks or temperature changes. Reliable ' I pressure maintenance devices do not interfere with the • ; ,d, prompt operation of dry pipe valves and deluge valves r : ; 0 including when used with quick opening devices. Listings and Approvals Model B -1 Models A -2 and B -1: 1. Listed by Underwriters Laboratories, Inc. (UL) ,\ 2. Underwriters Laboratories of Canada. (ULC) - 3. Factory Mutual Research Corporation. (FM) 4. NYC MEA 258 -93 -E. U P:. ° <>- Models B-2: tt o 1. Listed by Underwriters Laboratories Inc. and UL certified , � for Canada(cULus) s , 2. Factory Mutual Research Corporation. (FM) . . i , 3. NYC MEA 258-93-E (pending). -...:.%. .- Model B -2 The Reliable Automatic Sprinkler Co., Inc., 525 North MacQI iesten Parkway, Mount Vernon, New York 10552 Operation Model A -2 The Model A -2 Device is designed for use where a Sh Ltoff ((, source of compressed gas is available, such as nitrogen v \ . 11 1111110.70-- ` cylinders, a plant compressed air system or a tank p pressure � , • C / Axiom! mounted air compressor with a ressure control switch. :� ,., . �V v ur : 'r Prteunasc The pressure of the compressed gas is reduced by the ac's ., st, / i; �„@ regulator to the level required by the dry pipe, deluge or ri �= vale preaction system. The Reliable automatic pressure t�tAir R.44 , Carman �r maintenance device will maintain a constant pressure in storP@rog� mi k4._,., \ .,� the system regardless of pressure fluctuations in the Rog , 7 - `i Z � M., compressed gas source. v �,1 The strainer prevents any foreign matter in the gas i from traveling to the regulator and check valve and inter- To fering with their normal operation. The check valve pre- System vents reverse flow so that water cannot reach the regulators after the dry pipe or deluge valve operates. Model A -2 The shutoff valves permit the servicing of the strainer MODEL a z and regulator without shutting down the sprinkler sys- Pressure Switch tern. The bypass valve permits the rapid restoration of , — , the required system pressure after service or operation. MonEC 13.1 ` The bypass valve must be closed and the shutoff valves I _' , r S � ,, 'O I MODEL Switch open for proper automatic operation. , r, I with � — \ with er Valve � rr � r, .i on Bock Face to Face Dimensions: 11 /4 (286mm) Strainer ) Rsir ns ,con Pressure Rating: L l % Adjustable Range: 5psi to - 50 psi (0,3 bar to - 3,4 bar) shutoff ■ Value G,rce ta/ve Maximum Inlet Pressure: 175 psi (12 bar) �rcrn t '•�; Note 1 bar = 100 kPa >. "� ''"` AV Pressure awe s Models B -1 and B -2 un4less G G'auye onnect,on Cor.apressor z . � r,,,,;.., 1 The Models B -1 and B -2 Devices are designed for use � . �— ; in conftanction with Reliable Model A or Model B tankless Bypass . air compressors which do not have a pressure control 5,. ° :m switch to maintain the correct pressure in a dry pipe or 25OrG0?B d eluge valve system. By wiring the compressor motor to — Model B -1 and B 2 the electrical pressure switch of the Reliable Model B -1 or B -2 Automatic Pressure Maintenance Device, the Electrical Rating compressor is controlled by the selected pressure in the 115 -230 Volts DC; 3 HP (B -1) dry pipe or deluge valve system. 1/2 HP (B -2) ! A drop in the air pressure closes the pressure switch, activating the compressor. When the air pressure is re- Single Phase Three Phase stored to the pre - adjusted setting, the pressure switch 120 Volts AC; 2 HP 120 Volts AC; 3HP opens, stopping the compressor. The electrical ores- sure switch is equipped with an unloaded valve which 240 Volts AC; 3 HP 240 Volts AC; 5 Hp automatically bleeds off the compressor outlet pressure 600 Volts AC; 5 HP 600 Volts AC; 5 HP (B -1) (through the copper tubing) each time the pressure 1 HP (B -2) switch opens. This protects the compressor motor from Model B -1: Pressure Rating overload at the next startup Like the Model A -2 Device, the Model B -1 or B -2 has a Adjustable Range: 14psi - to - 60 psi (1,0 bar - to - 4,1 bar) strainer for contamination control and a check valve to Maximum Inlet Pressure: 175 psi (12 bar) prevent reverse water flow. The bypass valve and shut- off valves are identical in configuration and function as with the Model A -2 Device. Likewise, the bypass valve Model B -2: Pressure Rating must be closed and the shutoff valves open for proper Adjustable Range: 3psi to 35 psi (0,2 bar to 2,4 bar) automatic operation. Face to Face Dimensions: 91/4" (235mm) Maximum Inlet Pressure: 175 psi (12 bar) Note: 1 bar = 100 kPa The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly I qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by - Recycled The Reliable Automatic Sprinkler C o ., Inc. Paper (800) 841 6051 Sales Fax ces eI ( 848 3171 Sales Fax Revision lines indicate updated ul nuw data Nil,,, ir;F1. 317„) G len ui Addi L 1; .es hdunwl �IrJru I'rinlucl U' ;n I I/n l h/N lu a,o; nres l Ni /�www i �.li�l. �i n FIV 05/10/05 14:41 FAX 2537969155 PUGETSOt7ND PIPE li0002 • PIPE A-312, .SA-312 These specifications cover both welded and seamless pipe. The SA-312 is to the ASME (Boiler) Code and A•312 is to ASTM specifications_ All of the welded material for mese specifications (up through 6 inchl is full finished, annealed and pickled, and has no filler metal added. The specification for 8, 10, and 12 inch pipe would be A -312 as welded, annealed and pickled. Both SA -312 and A -312 specifications required annealing at 1900°F, minimum. A 376 This is a seamless only specificiation. A 358 - Class I I This specification designates that the material is intended for high tempera- ture service, must be double welded but need not be x- rayed. Class I material designation requiresthat the welds must be x•rayed for soundness of weld, This specification is not normally called out for material below 8 inch. This also requires that filler material be added, a direct contraoictlon to the A•312 specification. TUBING A -269 This is a catch -all specification which covers both welded and seamless tubing. It requires only .an-average .wall tolerance (1096 variance), basic chem• ical properties and does not require any cold working in the weld area or any cold. drawing. A.249 This is a minimum wall welded condenser tube specification meant for use in condenser, teed water tubes and evaporators. The wall size nominal gauge is the minimum allowable. Cold work In the weld area and/or cold drawing of some sort is required to meet the minimum wall) requirements. A-213 This is a seamless minimum wall condenser tube specification. • Salt 2274 Lake C lt y , Rose, Ulan s 410 M ULTALLOY 17160 d(bunle Ave. Salt ke qt, Ul 6a Artesia, Ca6lomia 90701 801.973.9339 • Bo0- 845 -8922 , 182111 Olympic Ave. S. 38 2- a02- 6836.80Q -846 8922 Fax 13 -9 -9352 Tukwila, WA 98124 Fax 562-402-3847 6 S 8 (425) 555.0125 • Fax (425) 656 -0131 T SS5 96L 52 +:at :mou4 00:17T i? -81-1 .. 51717669092T:01 : W0dJ i2S : 80 9 002 -0T -Nt lr a -15 - 2006 12:52P FROM: T0: 136 @699448 _ :1'2 • III Designation: A 312/A 312M - 99 a '•• <IP Natia+a a ndards n A in U9DOt iota standards i a fi Standard Specification for i q qt., :1 eamless and Welded Austenitie Stainless Steel Pipes' 'I1 ° 0, This send fd if iUu 4 under Or fired saelgatuioa A 7 t2lA 317Mr t he number mnireodiarsly following die designation indicates the year Il 1� A N A $ ' of Ongm r adapeina a. m die cane o(eeviuwa_ the rent arise re.nien. A number is pea atlttan mdicrce du you' of Luc reappcavat. , ilk,. 1 ri . y , ` n t tfs , � r 1` J A atspauript t+pfiloa (s) ittdi�t[e+ N edeterial assess ulnae the !me revision a ruppraval. 1.,..: I y , H { ,{ F•. • � l Mir .crandard has been approved for tva by agencies of Me Deaanma t tlf Drif ee. • tP . "' , , I..1i t ZT tx "F i ,.hi, Scope 1.6 The values stated in either inch-pound mutts or SI units + Ir1; 7 h {.. .l t i I.l This specification' covers seamless and straj&llt -seam are to be regarded separately as standard. Within the text, the � ' ` i 4 'tr, k , ',< ;Ided austenitic steel pipe intended for high- temperature and SI units are shown in brackets. The values stated in each ; (F t } , neral corrosive service. system are not exact equivalents; therefore, each system Invst F, ti, , : li *Pa 1 —when the impact act criteriet+ for a low.rempcsatute service be used independently of the other. Combining values from the i , r ., 1, two systems may result in nonconformance with the ecifl- ; ,,,.. ;: , S - turd be 15 frlbf [20 JI energy abscrotjon or 15 mils [038 rum) lateral e ' xtt i4 r: oaASion, sow of the mwtcoitic stainless steel grades covered by this s specification is specified in the ordetc . cation: The inch -pound units shall apply unless the "M" S I , ` F t + ' :dficativn era accepted by canna vent/ or piping codes designation of this t l t I ! t ? t ; r , shout the naeaottity of ma the rental rest. For exam pre, Grades Nara 2—The dimensionless designator NPS (nominal pipe size) Bas t s ' "+J" . '304, TP304L, and TP347 are accepted by the ASME Pressure Vessel born subsciaucd in this standard for such trodititmal rstsg6 34 "nomiAai 1, � ;r L° . de, Section V1X Division 1, and by the Chemical Plan and Refinery diamom "size." sod . set ___ stzr_'• 1i fi,S1e T ens Code, ANSI 8313. fec =nice at tz ,aratures a9 low as _425°F i(;�, Ei „ , ' l :Svc] without qualification by impact testa. OthctALSI stainless steel 2. Referenced Documents !,. :'•,! :. ,din are usually accepted for service tempersturet as low 4e -325+F x+ 140 without impact testing. Xeipact meting may under cc 2.1 A .S TM Standards; ' :, ,,l, I : cuinstana ex e. be required_ Par ample, materials with chromium or A 262 Practices for Detecting Susceptibility to Intergrettular ii i t ,i,i 1 . •kel content outside the AJSI ranges. and for material with carbon Assert in A stenitic Stainless Steels 1l I s + z ateac exceeding 0.10 %, arm required to be Impact tested under the Tales A 370 Test Methods and Definitions for Mechanical Testing ` $ �f r �?. ASME Section VIII Division I when service temperatures are lower of Steel Products.' ���h ' - y 'i l � A 450/A 450M Specification fat General Requirements for t r i ' ; i 1 4, 4 ; .2 Grades TP304H, TP309H, TP309HCb, TP310H, Cerbon, Ferritic Alloy, and Austcnitic Alloy Steel Tobes � t t , l iE 310I1Cb. TP31 TP321Ii. TP347H, and TP348H are A 530/A 530M Specification for General Requirements for t , ' 1Y ', xiifications of Grades TP304, TP309Cb, TP3093. TP310Cb, ' Specialized Carbon and Alloy Steel Pipe 111i r t , T. '3)0S, TP316, TP321, TP347, and TP348, and axe intended E 112 Test Methods for Determining the Average Gra t _. r high - temperature service. Su ,1 t r .t ^, 1.3 Optional supplem ry Ulo enta requirements are provided for E 213 Practice for tasorlic Examination of Metal Pipe i ' r 4 ,' y 3c where a greater degree of testing is desired. These and 'hrbingd i i ,i ` 7 i '!.. 1 a pplementary requirements call for additional tests to be made E 381 Method of Macroetch Testing Steel Bars, Billets, �� '' `! � !' pF d. whets desired, one or more of these m A ' r i t t r ter. Y b s De cified in the Blooms, and Fo1 gs 5 r � 1 F 1 , 4 t ; 1 , ; ' E 426 Practice for Electromagnetic (Eddy- Cuatnt) Exatai- I t�G.i t '' t' " I.4 Table X1.1 lists the dimensions of welded and seamless nation of Seamless and Welded Tubular Products, Austen_ j ,rs; unless steel pipe as shown in ANSI B36.19. Pipe having isle Stainless Steel, and Similar Alloys ` �` ` y ' „ ler dimensions may be furnished provided such pipe ems, E 527 Practice for Numbering Metals and Alloys (UNS) �tr� F is es with all other requirements of this specification. 2..2 ANSI Standards:' 1 !,;;_.;.•`id`s - ,,,4d_ 1.5 Grades TP321 and TP321H have lower strength requite, B1.20.1 Pipe Threads, General Purpose y t 't l ' ii' l let :nu for pipe manufactured by the seamless process in B36.10 Welded and Seamless Wrought Steel Pipe t lift '. l ruinal wall thicknesses greater than , A in. [95 mm]- B36.19 Stainless Steel Pipe ` l �i• , i r I i l . ' The+ ipecitieatina is wader the juti.+dicdsm of ASI'M Cammi�t A..1 ea Sift). 1: y ` r betesx Steel. end Reused Ano a +apeatitxliry of Subramaritrre Annual ua! Hoek of A.`'M Srandardr. Vol O1 •tri. � nd is tae dutxc s �p, ! ti , : : i . } 7 1.10 p , �y se Swat A lbin& - anneal Book of ASIA! Srandmde 4b1 01,01. 7 Current eaitioa approved Tan 10. 1999. published April 1999. Originally ' Amu&Book afAt7lt/SeancJand:. vat 03.01, 1 id 1 tt4 i? d',abed ac A 312 _4d_ T. Lea Preview °dui= A 312/A 31714 - 9e. 1 Annual Beat of AMU Sranderae, vat 03.03, G .r.;;;•1, t , , Ea r ASME Boiler and Pteseure Vn,al Code applications ace Inland Speed- ' Available hash American ;national Standards Ioseitnte, 11 Wcec 42 as,. 13th ; 0.1;11 t : I t 4 on SA -1l2 in Samoa IT of that Coda. Floor, Nee York. NY 10036. r r r ; r t'.;111 it ' ,. I ,s! •1>4 P.it Ik t4� t,, vty t a ASTK +00 Sae roroar Orivq Wage ecmcnoneeKen PA , 94aa 2f6e, United Wail. 4 i L: : ; .x i;;,;; tfi y', t 1 177 v, I.1. � ,qt i l MAY -16 -2005 10:32 253796935S 96% P.22 4 - 15 - 2006 12:52P FROM: T0:13606994425 P:2/2 u.,•A VU A V. wO ;A_la £VVI - - I b ‘70.• A ./V♦'••Y •_ • 4 • fr.'- . ilgito A312/A312M ` TABLE 1 Chemical 'Requirements of . • i '. ' ` R0610altlon, s INC V _ ; _ 0 '. Carton xhax' • D , Salon 603°22 Mdad CMOmun. �°Y� n s is � nm 9 �c 1 cow, 46.082222 9mv, WO. roux 4 ;• T pyy, 400400 0409 2.00 0.040 0.070 0.75 max 5.06 -11.0 180••200 , . ... ... .. - ... . , . ... • ' 6L$0430 0.044 -010 000 6 0'7040 0.0 a79 num 000.31.0 10.4.40.0 tq � '•%+ L 90000 0.005' 0440 0.000 0.70 aas 0.00 -0(0 10.0 -300 ... ... .. .. ... ... ... ... 71.10416 600461 054 00 0.040 6420 0.73 malt 6.00 -170 180 -205 ... .. _ ... .,. 2270-0,46 ... .., ... d ■ .. 7.30 800460 0.086 2.00 0.040 0.060 0,75 ntet 0.00 ■110 160 - 140 , .. .:70010: 0.20040 0.0E 200 0.449 0570 0.75 mac 12.0-10.0 224 -24.0 6,75IP4a . - - 16 x C - .. ... ... ... C. ' * 1011, d' max 3 .. n /7.309“ swop 0.04 -0.10 2-m 0.040 0110 COI .,.a 40.5.115 22,0.24.0 .. • . - _ _ . , , , . , • ... ... :• 4 .. • wtlm0M 500041 0.04-0-10 2.00 0.046 0.070 0.76 ma n -0.16.0 24.044.0 0.76 met , , . 10 x C . , , , , r • • : `.:= 43 /7908s 30908 050 200 044 0290 0 son 12.0 -10.3 22.0 -24.0 0,75 *404 s ' ••10 34 71034 6310 0 2.20 D.040 0.000 10.75 ma 19.0 -22,0 24,0.29,0 0,.42284 ... 10 x C ... ... ... e r.Q i (, r ;/- 228.0 ',; "T4acam arms 0.04-0440 2460 04040 0,070 375 ma, 18.0 -22.0 24,0 -2 .0 ,,, .., .. ., ,,, • • : _ . : : 4 , 1 p 9 7 0 M C 5 531411 0.04 - . 2.00 0.062 0270 01S'mox 15.0...V4 24.0 - 260 0.75 max ... 10 x C .. , , , . .. • , • 7 . On. 1,70 MX ,'; .11:"..,!901105 941038 DR) 2.00 0.081 0410 an MU 180.24.0 24,0403 0.76 mots ... , .. • , , . , . • . ... _; ,.. 89,271 0.08412 1.9- 00 0190 0.015 036-7 14.0,065 14.041 33 1.0 -1.4 0 0 0.6 0 "�� " 14 =4 • ` ,' TP916 571000 030 230 0.060 0.090 0.76 ark 11 X143 0 160 -100 2.00 -8.04 ... ... ... ... _.. ... i • * • ' • Two( 871600 054 -0.10 200 9440 0.440 an era 11,0 -144• 12.0-13.0 :00-1.05 ... ... ... ... ... .. • ... - " ?' - 019101. 091602 1026 202 0.040 0.692 an woo 10.0-16.0 110-18.0 23040 ... . . r: ;,,n62•674 33101 026 250 0140 0.070 075 mos ,14 -14.2 +6.00 7404,00 9.10-0.19 , , . .. r . I . ' TP3161•J4 613/4,53 0.005 230 0.040 0.030 0740246 11.4.143. 163 -19.0 1.03 -80 ... ... -.. 0,10.015 _.. . � - T►N7 001700 0,0E 230 0.040 0.090 0.75mea 113-040 183.00.0 3,00-4.00 ... ... .. . >TV217L 131707 0.096 2..O 0.040 0030 07622.44 11.0.16.0 163 -204 2.0 -4.00. _- .._ _ .._ . . . . . - - . . . - • - • -__ - ' - - 1 ' ; " '' 17321 002,00 048 230 0440 0.000 0.75 nu 1,00-134 174 -20.0 -- '' + 7,-.=. 'TPIIIM 8>?700 03440.10 100 6040 0370 0.77 ma 9.00054 17.4203 • , . • " 03 0.09 240 0-040 0.030 0.76 max 100.134 17 _ _ - 04 ,; • .Tr3cm sum 0.04.8.87 7.w 8 30NM 9. 0 0430 0.75 n00 -134 17.0.0403 ... ' .. _ . . , . .. • • - 41. ' " ' . 710471./4 094761 Lee& 7.00 0.040 o no a s r 6.00.12.0 17.0 -90.0 ... , , , 02.04 • . , 00040.10 ... Ar n1, 0330 • ;; ,.TP946 534600 0.09 250 1040 0350 675 ma 0.00.01.0 +7.0 -203. ... .. • " 0.10 - • • _ - • - • - . 'w'!`'.' 411 934600 0.04••0.10 2.00 0.040 0.030 0.75 max 6.05 -753 17, -283 • . - , . • ' 0.10 . • ~' • '.TVr►4 t5 0 1830 606 6.044 o 0444 0.695 tm ma ssa 75 18 215 .. . , 0.16440 ... •.5 10.00 TO04-01 511904 0.04 5.00- 0.040 0.030 1.00 malt 660 -7.50 18.041.5 4 +6 -140 . - - _ _ . 'ktr; -� 10.00 • r ` t c TPx./4-16 306100 0.06 2.00 1070 0.030 140 -2. 0 4733.103 173 -18.0 .. ... ... .. • 3- 7715 -1t 320910 Q. 4.00- awl 0.670 730 rut 113 - 133 2 -73 13040.0 ... 0.10- , .. 030-0.40 0.1x- f 3.00 0.80 0.80 T 73 47 53 4 4000 03 n 3. 02 2 K..6 e0 0.666 4.5 1400 2202 .75 17.0 ■19,0 ... 504..0 40 ... ... 143 r 53+064 0.020 • D2 0.05) 53+9 0.90 sues 17.8.084 145.20.5 1.03 ... ... ... 0.16 -080 ... 034.1-00 , _ _ seams 616-020 2.00 034 036 9 .2-..o +1.5 -+eA 173 -1 7.6 ... ... .. • ... 0.6- ' • :' 0.63 650515 105.0.10 0.30 0.840 0330 1.40 -4.040 104 -12.0 266220 . • . o is 0040 ... o • mae 0 .421 210 3420 0011 004 204.044 2 4.4.20.0 1. 6-16 ... ... ... 0.164.15 ... _.. ... _ 630500 0.016 2.00 0.02 137 s.7 -•4.3 11.0 - 155 110 -tab 0.25 max ... ... ... ... ... ase me ... 5117 0.03 202 0440' 0.030 176 135. 174 704403 4,0.42 .. „ • „ • 0,1042244 , 0701/154 . 651710 033 2.00 0460' 0354 676 133.17.0 17.0.253 4.0433 ... ... ... 0.104020 . , . 076 m66 ... ... 550215 002 2.00 0.045 0.054 4446.0 16,0.22.0 445.835 0.5•1.5 .,. .. ... ... 13-2.5 .•. 332nd 3•.4 '3 5.03 0.015 04 a1a 314334 25.04534 ... .. 0.0-1.0 . • .. . • . 020- . • , 0.44 ate to ... 4424666 203 604.0 0,010 2,010 1,00 malt 163410,0 21.0.2545 4.0-34 ... 0.1 max o0. o0. . _ . _ .. n ... 21041E 0.044.00 461 5.045 0.070 +.00 -0,00 530.10.0 1 3.0419.0 .. 0.,?.e,a .,. 0310 6320334 9.624 2,00- 0.050 0,023 0.40 matt 21.3-24,0 74.3.25.0 7.00 . , . ... 843 -455 ... 030440 . 4.00 $00t5 104408 242 0.045 3.030 4.75 - 646654 24.040.0 ... 0416041E 069- GAS ... . • • 1403367 0.030 2.00 03 0.030 130 max 2160 -25.60 7..00 -22.00 6,00.1.00 ... ... 0.19421 ... 0.78 arm •' • • • • 0067204 0.020 2.00 0445 0.35 1,00 • 210 -28-0 194 -234 0.2-53 . ... .. ... 0.10 .n0. ... 1.0.25 -. - i t Maw X 604680063 In s63004602 00101 Awoke E 827 and 64E 41086. ' 1.1Wen an. w W1wots• V'06400. t The 02410160 of e001100 ter 0 0100 111 3 3 00 00 a 0164417 01 eysonor t Wow to poof oast and nWMl3Onr. ° For .owed 1P316. TP910H, 3l64N. and 1751 cos, the rico 1 ranOo 41106 be 1 0.0 - 14.01. . 0 Far 644405 33040(0, 0t Dan 0409 or 00221, Om nary dma3tp pawn mu regtar9d, a 4,6.6020 1ng6rxan 80 0.0401 el naa2sewr in puma 0440 7P$16L Smog nun 6422.41. 002190•070 40640 eo 81080 loss men 0.500 r. p2.7 men] 10 w estle Owosso and 5301 mate tee. as 01044 luee elan 0,010 k 1110 mml h ww4ge we 0eean4..40.604 • 4 0)010, 111b40ra0114440 raaa104ats. 'The h4r4xn Oolat tool is not Ilea 1714s 100 sumo: 5o 01 tnllea 4 atl rex more Olen 0.701. . i * 700 61•0u61 0061.010 *t310 004 CO 000 1000 91an fax Ones 014 066504 06114n1 and not more awn 0.001 • 110 seL640um 9t10 00001.61 0011461 0240 04 rot 0a than Pen comas ore C*030n 06444221 440 4101 was *110 1.00 1. ` odwablarn Oka tantalum 00n1°n1 anal h° nix 14104 enen 41311 Wry ate earOc 1 30006 6111 "01 0(046 dter 1.0 %. !Pa" 040064 pbs, 3r pnatpna bram tm maa 5100 44 be 0 5 s. i ` Canoe 634751 ana4 neve a 0050218x22 (n161160 pm cantata° conewa at 1104 dew than 15 Wnee me worn oonmm. •. 179 • .. MRS' -15 -2005 10:33 2537969355 954 P.03 JAN -16 -2006 09:23A FROM: T0: 13606994485 P:2�3 - MY :i7-NOS TUE 09:42 All STATE PIPE FAX NO. 3607501364 P. 02 '• ; la tleataiiii* WK. ;•.t, __ �wrw srnra ..n..n..w..w.w.w•.�....+r If , ........ ra.- r• v-- �. ..-- �w.......••..�+'"".w+�•e,w" fi �'!� J1 16941 r f Steel Sprh Ider Pipe , _. ....,.._. .,r IrN... _ ....... �n -.n..� Steel Sprinkler Pipe • nkler /per\ �IOT� I L ' YEW PM �`►I�TER CO LTD f.. 369YUMORD ., : CI TOTS � AO SIANG KA,OHSTONO MEN 825, TAIWAN f ,f dl 1-1/4 thy:Rill 4 in, nominal diems for wet, Thy perm and ddb the � SE'S � ends invaded to be joined by welding or by Listed tubber socketed Minos as systems ; ktidicgted in the infividuai Tied under The . to Fl inn% and installed in aced a with, the flitting �s specifications where Wed Pte° corrosion ' mistime* reties (G') are as faunas: MR 1, thatiinseedded Pipe 3n.Oed Bore (! 3�6 a. 175 t l'M MIIIIIIMIIIIIIMIIIIIIIIIIIIII21 1-1/4 4.01 EllIMmmlim ; Ell. 175 l on 2005-03-07 r Patge Top. C1111.11111 �.... wl- wiW ++M.. •1. Y rfIY. Y 1rM11....• � '•••y V, w« .. w . r . ��, rT. w..... �. M' .. " •wrv.•►..rFwr'Irw � ."•• �� ... . tialmatpiarbiacar Ittiatisse Prtavinus P ; This page and all Qonte is we Copyright 2005 by theterwrisa$ Lemmas Jna* s . bttp ;!ldatziese•tiLeomlcgi4oio/XYln PZ°teiLISEXTf In , !showpoe hxmliname -.. 05:02753 . JAN -16 -2006 09:24A FROM: T0: 13606994485 P: 3�3 • I1AY -17 -2005 TUE 09:43 AM STATE PIPE FAX NU. 3eormul;1tf4 r. U i � OPPoollnes of pO& e* in t database d tt •� tnbaLi steenstwoned under 'Ws Faila�wUA 8 � Cody thew ���, • tad oavated under Fort UP S Yi4A• Alaray of pp tediotheOnliaa "sties tel thefollowing ca vomits '�° 3o their a tree n' aid at swan- . camdldaoc L.'Iba Outdo 40.+Bp° ra Listings (thy fib° Pad at ate dins (er &nvdue*• 2. 'The etenenteni Iltettonen ham the Winn with yeendenew fans theinewiters Lebow:once bee seat Weir WO ts toduighslusl Ia ms, Ws •r add 1nolvdo ciatiitigit sok*indie fan gf " 0 Uadomitags L • i •, r; • • ■ • . • f • • • • httpf /dalabase.ul.cowlcgi -biVltiemglatel •IS XT /Int.aMFlabonag&brearriamemeit ... 3t7/20o5 , • T1111-p. JAN -16 -2006 09:23A FROM: T0:13606994485 P:1/3 +.1V - 17 -2006 TUE 09:43 API STATE PIPE FAX HO, 3807501364 t U4 <\\\. . .V . 1.4. ----------.-- „per Foot for SPS flow Pips - Pipe $1ze inches WtJF't Wt./Ft Nominal °EU Wan ID (d) without Water with Water ^— Z18 1- 114" 1.660 0.083 1.4 4 • � 1-1 /2" 1.300 0.095 1.714 1.53 283 2" 2.375 0.095 2.185 2.32 0.84 2 -1/2" 2.875 0.083 2.709 2.46 4.97 3" 3.500 0.090 3.320 3.28 7.03 . 4" 4.500 0.101 4.298 4.75 11.03 Bund ling hart for SPS flo Pike LBS. Pipe Size MICErilli Pce. Per Wt. Per Wt. Per Nominal OD Wall Wt./Ft Bundle Bundle 21' Bundle 24' 1 - 114" .1.660 0.083 1.4o min 1881 IIM 1.900 0,095 1111Will 2464 2.375 0.095 mg. 2042 2934 2 -112" 2.875 0.083 39 2140 3" 3.500 0.090 � 2e � 88 2Q47 - 4.500 0.101 19 21 rircrlow ,, l :a1 x. t -. L xi . Listed Fti I L1 CUa.{ TM ra .. I I ist@d: ' , TM .,': Choose the lightwall steel sprinkler pipe with superior hydraulics, performance, -!N 1 and value to Schedule 10 and Schedule 40. Approve!! HYDRAULIC COMPARISONS FRICTION LOSS (PSUFOOT) C -120 FIREFLOW high- strength lightwall sprinkler pipe offers friction SIZE GPM FiREFLCV1' SCH. 40 SCH.10 loss characteristics far superior to Schedule 40 or Schedule 1 114" 100 .4364 .6721 .5426 10. The result is superior flow rates with many important 1 112" 120 2979 4445 .3592 added advantages. FIREFLOW's larger inside diameter allows 1. 150 .1396 .1989 .1616 you to down -size system requirements for greater cost efficiency. FIREFLOW sprinkler pipe is easy to cut, fabricate, 2 112" 300 .1873 .3018 .2198 and install. And FIREFLOW assures long -term durability for 3" 500 .1762 .2696: .2006 greater life expectancy. 4" 1000 .1819 .2588 .1965 row.. SOOT COMPARISONS SIZE FIREFLOW SCH.40 SCH. 10 1 1/4" 128 2.27 1.81 When FIREFLOW is produced, the standard eddie- current 1 1/2" 1.48 2.72 2.08 exam is performed, then each length of 2" diameter and above 2" 1.87 3.65 2.64 material is pressure tested to 300 /psi. 2 1/2" 2.27 5.79 3.53 3" 2.78 7.59 4.33 4 " 4.05 10.79 5.61 • ,.4.6- e_E DIAMETER COMPARISONS SIZE FIREFLOW SCH. 40 SCH. 10 FIREFLOW pipe is manufactured to meet ASTM -A 135 and .1 4 ASTM -A 795 standards and is compliant with NFPA -13 and 1 1/4" 1,608 1.380 1.422 NFPA -14. FIREFLOW products have been approved under 1 1/2" 1.748 1.610 1.682 the following Factory Mutual and Underwriter Laboratories 2" 2.223 2.067 2.157 testing procedures: 2 1/2" 2.723 2.489 2.635 - 3" 3.348 3.068 3.260 4" 4.328 4.026 4.260 hill: / /www q+rinklcrpipc.cm/Firalow.htm (I of 2)8/3/2004 2:17:01 AM µw e i v. TERFIT GROOVEDI. ` . h ,. INTERFIT GROOVED PIPING SYSTEM offers versatility, economy and a�n��d .� ., .. r netK reliability in the installation of piping systems. aaa.; nu totter '°' , OW an Vntror The Interfit Mechanical Coupling employs a lime honoured method ASJS,p "'.1 y a Manny boa which offers considerable savings in installation costs while :�.. •�� .. - _: -: substantially improving the piping system into which the couplings are : ;. . installed. Additionally, simplicity of installation is maintained in that a 4,-;-%:.4,-;:i . _ , single wrench and lubricant are required for installation. Along with the Interfit Mechanical Couplings, Interf it offers a complete _ , >: line of grooved -end fittings, thereby permitting the user to install a 4 _TE~ • completely Interf it designed system. Interfit Mechanical Couplings and - : � ° ,� Fittings are UL & ULC Listed, and FM Approved for fire protection , sav and +w systems. ran a v per �,as The Interfit Grooved Piping System is approved by many state an si ,,,�,. d sled ma \ � -� ASrdiI. o municipal authorities FEATURES a REDUCED COSTS UNION TYPE JOINT Coupling assembly is quick and easy. Couplings an be disassembled easily Special training not required. The , permitting maintenance and servicing of the piping system. It will facilitate illir•-41111,—.-- system is free from contaminates such - " -- periodic rotation of pipe to distribute as weld slag and pipe dope. II IL periodic wear from slurries or other _ a . Installation cost are controllable and .,, abrasive media. estimates are more precise. DEFLECTION 82. MISALIGNMENT RELIABILITY . the pipe around Precise location of pipe openings r" pe The couplings engage p v the entire circumference and restrain \a / .... / the pipe ends from separation due to H unnecessary. Long radius curves may I pressure and other forces, up to the H be designed with fewer elbows. Useful • for providing pitch for drainage. through walls and floors is for providing laying pipe on rough or ›. maximum coupling rated working -. T ,, : „� ,%i pressure. re ssure. r uneven terrain. EXPANSION 81. CONTRACTION STRESS -FREE JOINT , ,.. Flexibility of the joint reduces or Provides linear movement at each eliminates stresses from settlement of joint Allows pipe expansion ands, '' buried pipe, or induced by seismic t.� ; i/L, contraction. Suitable for hot and cold tremors water lines and dual temperature ,-.;” --. -- systems. ,; ' L' J -_ t''' " NOISE 81, VIBRATION RIGIDITY y - p Couplings available for rigidity at Slight gap between pipe ends isolates valves, equipment or mechanical a r �; a4 -, noise and vibration. Resilient gasket rooms. Couplings grip pipe to provide also helps to absorb noise and a rigid system Used with standard vibration Often permits elimination of groove specifications. --- ---� +/ noise suppression devices. Distributed by: The Reliable Automatl[CSpratkle>t' " Co =tlic- 3 •_,_� �,.. .. a �;` k� -> i s ' �s - 4x`4 t`"` 4 '" .S- .. �.. ....,... ..A . ,. ,,.. �... ,..I v^ i ;. s v F.. a "� .P s . k n'� t v ' fi � a roo ��� . 14 T yLE h i t e rf it s � . u Approved P i p ing „ , G ru v- Flange �� i .: ' : ' — Z STYLE 1 4 T _ _. +p GR U V FLANGE Allows direct connection of flanged components to a grooved system. Housing Y O q` e 0 X are hinged for easy assembly. Single gasket, especially designed, seals the pipe p �Q and mating flange. Provides a rigid joint with no angular or linear movement. Dimensions Sealing Surface '+ Nominal Pipe Maximum Maximum No. Bolt Size O.D. Pressure End load X I Y I Z A Max. B Max. Bolts Size Weight Inches Lbs. Inches Inches P51* Lbs.* Required Inches Inches 2 2.375 250 1,105 4 5/8 X 2 3/4 6 4 3/4 3/4 2,375 3,406 4.3 21/2 2.875 250 1,620 4 5/8 X 3 7 51/2 7/8 2,875 3,906 55 3 3.500 250 2,405 4 5/8 X 3 71/2 6 15/6 3,500 4,531 6.1 4 4.500 250 3,975 8 5/8 X 3 9 71/2 15/6 4,500 I 5,531 9.7 5 5.563 250 6,075 8 3/4 X31/2 10 81/2 15/6 5,563 6,718 10.5 6 6.625 250 8,615 8 3/4 X 31/2 11 91/2 1 6,625 7,781 11.8 8 8.625 250 14,600 8 3/4 X 31/2 131/2 113/4 i 1 1/8 8,625 9,938 _ 18.2 10 10.750 250 • 22,690 12 7/8 X 4 16 141/4 1 13/16 10,750 12,312 24.6 12 12.750 250 31,920 12 7/8 X 4 19 17 I 1 1/4 12,750 1 14,312 32.6 _ _ Maximum working pressure, End load, Pipe end seperation and Deflection values are for Standard Steel pipe, cut Grooved. For standard Roll grooved steel pipe, Deflection and pipe end seperation values will be 50% of the above values. Distributed by: ietp Tnut> °Sp>� ;.•.I ° The 0'0Z DI ill I ►'S l tl rnntarNIMME 8/ES LiIil B/Lt t /19 Z/19 1/15 91St 111E 051 051 t x 8 Ex Z'll 9'11 8/St Val 8/Lt t /l9 t/19 9VES 8/ll I t/ti 05Z L/1Z 8 8'01 E'► l P/19 8/E 6 91/LIE B/E S 8/E S t/ I t 5/S t U 051 PI 9 94 101 8/E5 01 91/11E 8/15 7./15 Lilt 8/SE(VIE 051 Ex9 II U 8/St DI 9VIIE 8/15 5/15 91/Et 8/1i (t/El 051 i/llx9 fL 11 8/E t 01 91/111 8/15 8/ I S 9L/LP 8/51 1111 05Z ix 9 YL fl t /EE 01 9VLIE B/1S 8/IS 91/Lt B/li 1 051 Z/lix9 - 87 t /EE 01 91/111 - 8/IS 91/Lt 8/ll 1 051 tit ix9 t'6 61 5/E 5 1116 WI E 8/5 t S t 8/5 E VI E DOE E x 5 6 L E'e 8/5t 1/16 ill E WE ► t/E t 9 VE I E 8/L1 t/E Z ODE l/I l x 5 9 E'8 8/E t Z/16 ME t/E t t/E t 9 V1 t 8/S l Z/11 DOE i' S r t 97 WEE Z/16 WI E t/E t t/E t 91/11 I/1 Z 1 ODE 1/I I ' S 9'9 FL tits t /iL 8/St 8 /It Lilt LiIE 8/51 Z/1E ODE Ext. 5 YS 8/5 t 5/5 5/5 1 t t 9E/1 E 8/l i t/E l ODE Z/I l x t. St S 8/E t 8/S L 11/51 t t 9V5 E 8/S Z Z/ 1 l DOE i x t E3 9't WEE t/l i 8/51 t t 91/51 2/1Z Z ODE t VI pt - 8 t /EE t /IL 8/S1 - 4 9V5 5/li i ODE t /llxt - Et VIE 9 1/l I - Z/1 E 9l/El l B/5 l 1J1 I ODE lx t - 8't OE 9 Lill - i/1 E 91/511 8/S I 111 l ODE t/E x t - 8't WEE 9 VIZ - i/1 E 91/511 8/51 111 1 ODE i/l x t t t't 5/It t /l9 B/AZ VIE i/It 9VEli 8/Si Z1ll ODE 1x1 LT • 61 KZ f /19 8/l i SAE 8/E E 91/111 8/1 l 1 ODE Z/l 1 x E It Et WEE t /19 8/l1 - 8/EE 9Vtll 8/li Z ODE t/1 1 - ii RAE B/L t 91/511 " - E 91/51 8/S I 1/1 1 ODE I x 1 rt 8/lE 8/Lt 91/511 .- E 91/LZ B/Sl 1/1 I ODE. t /ExE - 1'► B/IE 8/t 1' 91/511 - E 9VLZ 8/51 1/11 .ODE L/lxE - SE 8/5 E_ l/l S 8/5 t - E 9V5 Z B/1 i Z DOE 11 t l x 111 l - 9'E 815E 1/15 8/S - E 9VSi 8/Il 1 ODE tit Ixi /ll - El 8/1E S B/5 l - WE l 9V11 8/51 7 . / 1 1 DOE I x i/l l - YE 1V1E S 8/S I 9VEi 8/S I Z/11 00E t /ExZ /l1 - 8/S I 91/1 Z 8/S 1 VI I DOE tit x zit i - CI EV5 E S 8/E t ., _ _ 91/11 8/L 1 WE I ODE i/1 1 x 1 - 8/E 1 - t/E l 91/11 B/L l WE l DOE t/I t x i 8/E I - B/S i W51 t l 8/S I 111 l ODE 1 x 1 - 1 E S 5/E l - VS Z 91/11 B/S 1 1/1 l ODE t/E x l - El E S 8/E 1 - 8/S 1 91/1 1 8/S I i/I l ODE 1/1 Z x Z -sq1 p -c N vI A paeoag I ? 111 'NI "X W vl aZ!S alai 1Sd M Ow SalPul puDig X umj (ounil 1/9 11133 P e nwa -g 15IN uotsuawip um apH 0'0Z S'El V 1 0 "6 0 "L - - IMMO proem OZZ 0"91 0Z1 S 07 01 rl O'P OZ " {60 ° RS t ' Viz z z✓1 1 >• /t I Pit ill Vs"' r ttudS. m azi aia •SSDDD SD pain uaq v pog 6/I E x Z/1 saJrnba8 -pua uru ad!d pa6o6ua of uru }o Jalua) uml} uo!suaw!p afow!zalddv :310N :Xci pa+ncros!a poaxll 641 worms 4s? 114I%" algolono oo an siatInO PapoaJll . 9M w p1b agsod U Pap 14 Pal D Wog! pl�O0 ad d x41 twDPin) 01 PaPP 1 an s&asaxl P� pr 6 rnoy lnl tpooua o sapinoud pup wwtud y c aaI- aip suoupu nf�a umxol ail 'nips 6uwwl atp anaoai DI ad ayl u Ira paw p apy v -add ay 6u>Eo u41:001 titn ID lapin Ism pin spot D apwnd stafuto 4xm'a p uoyaw t ss0) — 1sP"J111 slows] '1I!' 91 ®iAIS uI� im min° pBAootg tote( SI s1/IS 7a - Yf 1 3 "°1 d rv 91 a1fi1S - PaPna 5I a1rgS - Panoolg ¶3L-dVNS IVDINVIIXI4T "S �,,, ti .,a y Y ° § ` y yy,iy�`i, t,U..?, kifi{{4'44 4r- T,I ",1j' , f.'Af,1 „, i.. r r. r},o. Fi,.. , , ,,, 01,, t � jG* ! ° ^ r-0' m �i �`e �l i w�, s �i r� � d ; 4 . 4 ' 4 r ,,,. .,,$ - .*cf - t e a '� r 'hv t( yl.. '�` : r�r .h_'' +S a .9 K. +� t.�, �F � r � � �p "n ' 4 I t4prtXV e a 1 Z ' ��'t q • ', ^,� STYLE 25 i x . , a i5w� a (---) i 11 r* . L3 R e ductn C ®u � ® P i p � e . v st e m � Y k I °) # � t f 1Y . t a ----• Z Y STYLE 25 REDUCING COUPLING 1 g Designed to connect two pipes of different X sizes, eliminating the need for two couplings "' and fitting. Specially designed gasket with lia ,',‘ I„� ribs and steel washer prevents telescoping of �,1 smaller pipe into a larger pipe, during assembly. Deflection from C1 Dimensions Allow Approx. Nominal Pipe i Max. Wk. Max. End Pi a End Per Pipe X Y Z Wt_ a ' Size O.D. Press #re load Sep. In. Coupling !n. /Foot lhs. Inches Inches PSI* �s' p Degrees Inches 2 x 1 1 /21 2.375 x 1.900 350 1,000 1/16 - 9/64 1 . 53' 0.4 3 3/ J 8 5 11/8 1.9 1,5 - 64 0.32 4 1 /8 51/8 1 7/8 23 21/2 x 2 r 2.875 x 2.375 350 1/16 9/ 1 .33 3 x 2 3.500 x 2.375 350 1,550 1/16 - 9/64 1 - 17' 0.26 4 3/4 6 3/4 1 7/8 3.9 3 x 21/2 3.500 x 2.875 I 350 2,375 1 1 /16 - 9/64 1 - 17' 0.26 4 3/4 6 3/4 1 7/8 3.6 4 x 2 4.500 x 2.375 350 1,550 1/16 - 1/4 2 - 38' 0.55 6 1/8 81/2 2 3/16 6.4 4 x 21/2 4.500 x 2.875 350 2,215 1 /16 -1/4 2 - 38' 0.55 6 1/8 81/2 2 3/16 5.7 4 x 3 4.500 x 3.500 350 3,365 1/16 -1/4 2.38' 0.55 61/8 81/2 2 3/16 5.3 6 x 4 6.625 x 4.500 350 5,565 1/16 - 1/4 1 .44' 0.36 8 1/2 11 1/4 21/8 10 ` Maximum working pressure, End load, Pipe end seperation and Deflection v 50% values s are for Standard values. Steel pipe, cut Grooved. For standarj • Roll grooved steel pipe, Deflection and pipe end seperation values Distributed by: T► tReiiabieAutomatcc 'Spritt>klet - lt>rt m } '' .,' tiir A7 r4 4 , . iV f 't AY S I, T'.7.;' CV1 >C ;;Y. ,W {,r , M ,en i ":. » . ,-- ; .... Y. w'-t 1' .....,*,..1'47`11 ". t J "c t F � "h *� a n - 4 ,,,"/”.“.." -r v .,Hy } t J i _ ,', r �1: 'y- .,,,,,, .; „,v,„,,,, 1 ? , : -. , ,,,, tr ry ?w W ; t mr „r ,,-st r ' .. ` ::.1,1 h_n r .;1 i h i ) }. f ; ° r r s fr , t r e .4 , �' 1,.s ,'W, a.# u 1 f e 4 1 ., 3 47,2 S TYLE ') a o e - t fff I 8 r , � } 5 '' d 1 i`xk b 4z ' r �0 t ' ,. i Ri gl C®p g 4 �sfe tirp , , „ fn -- .. ,,,, ,a , . � �'' � ie. + � y T i 9 ,' R 1 a r 2 , t�s�K. ,t , � r n ? . "ct .. n J , (m Y o3 r _ . . R a s . •—,;. � ,,, ,.∎ . r C 7 r'';;.1 � ��, r `� i ��t4 �i,,t.�,� � . G , :,� y � i k t ',.i .� ��`.:i�'ai,� ..^ti + .� 4` 'r `M , n lh x .. ik 4 " • �' t s i 2 "3 r c. r r p _ F 1. �... , .. . + � ".�' ., . ' a c3 • r.. ,f - ..r '4 r �. a - . wR. °'. x ° y }t i � , V :?� .. 1 . ,. ' 4.l l l ' . -- STYLE RIGID COUPLING Provides rigidity to the grooved piping Z Y _,� system. The arrangement sections f 1 tongue and groove 9 ement of the p"IN 1 housings reduce flexibility and provides 11 1 el/ V.>> joint rigrdrty. ie M. • Di . • Allow Approx. Nominal Pipe Max. Wk. Max. End Pipe End X Y Z Wt. Ea. Size O.D. ' Pressure Load p Lbs. Inches Inches PSI* Lbs.* Sep. In. Inches 1 1/2 1.900 175 500 1 0.10 3 4 5/8 21/16 1.9 2 2.375 175 775 0.10 31 /4 5 21 /16 2.1 21/2 2.875 175 1,135 0.10 3 3/4 5 5 /8 21/16 2.2 3 3.500 175 1,685 1 0.10 41/2 61/4 21/16 2.9 4 4.500 175 2,780 0.16 5 5/8 71/4 2 3/16 4.1 6 6.625 175 6,030 0.16 11/8 101/4 2 3/16 7.3 8 8.625 175 10,225 0.19 10 3/8 121/2 2 3/4 15.1 V' ; Maximum working pressure, End load, Pipe end seperation and Deflection values are for Standard Steel pipe, cut Grooved. For standard Roll grooved steel pipe, Deflection and pipe end seperation values will be 50% of the above values. Distributed by: , The ` Reliable Automatic' ^ Sprinkler ,Co. Mc �+ k �9 4 :fl S y F C a 2_ . ra x- } x 1,' :±. A 44 .. i.'cl'. ,,$"-P -ri , -. .ut dt''I>. } ohs #�'t ��f S dG�1L Y� t aa- f '�'t ry ",''° `'i �'��r�� "" a an. i ktT '� c [ �. Y - '` c�F � � � F tr � : ' ! _ : s' y "� Y F X : g.. L }Y +. mr 4 /'{ 4-1'''' kv 1 � s r , :Isle- : t y. +' } ,`, i t t4 °-; ' 4,„1;,,i.,,,, }{ ,, � �4 � ��y . .`I�� ` . y t ro 5. . fit ,F', f Grooved End .,. �.,r z,�} }_ �;Ce e 1 + `ti , F' n r"f G '.°N . Aft f . r� t Z r.0 4+ [ p�.. 3 ; , x b+ F h.,. 4,. ^ d. . '.. '1e4 F . f + I 4k- "S Uz •,r' 1 I : x 744 4 . r t .ste t� y ti' T �o�"�2s^u �'� t. f .�ey -�"P �', 4.,,v 4 n a� R' t i`o � .r t vii .� Y - ,V;: -�`. 5, � .' : , fir F ` t v N d . ` , ,- , .. , i s f . , a 4 , r i .�' � e aID' 1� � .+ r' � • � i - �' r .t x•t A. s �'Y t r ° � � y-�Sl. °' , ,,, 7) x' 3 - i ' , _ 1: ' g d i, ,, . 1 S [ ;� N r el, � 4. f : y r's'. ya r ",: s -,> =.., 13"- , "il , 'ke 1 f'�'t ,, .. A4 4 f T' S ' �''•k- �. 1 @f'+> �..m f .. af' m ,sr i V rt `Kj l Y , , ,, .- .. c >r h � k ?.' . • s "R t 4� _ u ���� {A' R *r 1, } ,, q v � L��1"ri .�. � r} .. 4 • {h �'',' 'V ' �� ' xr ,.!Zr, 1 ', -., u k t a .. . . ,, .. n � �' � 4 -' 1 , � , ti ` ; � , Frictional Resistance ~, � 4 . a , -.� , - JAI, , 4 ,, Expressed as equivalent Straight Pipe -in Ft- Nominal Elbow Tee Size Inches 90' t 45' Branch I Run ' 0.8 4.2 j 1.7 t 2 3.5 I 1.8 8.5 1 3.5 ,Q `` r 3 5.0 2.6 13.0 I 5.0 y 4 6.8 3.4 16.0 I 6.8 5 8.5 j 4.2 21.0 I 85 GROOVED END FITTINGS 6 10.0 5.0 25.0 ; 10.0 Fittings are available thru' 12 inch in a variety of styles and are 8 13.0 6.5 33.0 j 13.0 designed to provide minimum pressure drop and uniform strength. 10 110 8,3 41.0 I 17.0 Cast of durable ductile iron, fittings are supplied with machined 12 20.0 10.0 50.0 20.0 grooves to exact tolerance ; , AR ' ' NCNI ,COETRCREDUCER 1 : ST.AND� �F'I1rI1vCS �.� ,._ �., ... :. . ,'. r.,.. C to Ea CbE ! , _ _ EtoE CtoE e a 5 N o. 110 No. 150 No. 140 - No. 100 No. 101 Concentric Reducer Nominal 90' Elbow 45' Elbow Tee Cap C to E t W t Ea N Size E to E Wgt. Size C to E W t. Ea. C to E W t. Ea. C to E Wgt. Ea. . . I lib Inches In. l In. lb. In. b In. lb. Inches In. 1 1/4 2 3/4 7/e , 0.9 13/4 0.6 2 3/4 I 1 . 4 I 0.5 2 x 1 1 / 2 2 1/2 1.0 1 1/2 2 3/4 1.1 1 3/4 0.9 2 3/4 I 1.8 7/8 I 0.7 2 1/2 x 2 2 1/2 3.9 2 3 1/4 1.9 2 1.3 3 1/4 I 2.8 7/8 0.7 3 x 2 2 1/1 1.6 2 1/1 3 3/4 3.0 21/4 2.0 3 3/4 I 4.4 7/8 1.0 3x 21 /2 T 1 / 1 � 1.8 _ • 3 41/4 4.7 21/2 I 3.2 41/4 6.5 7/ I 1.4 . _ 4 x 2 3 2. 4 5 7'8 T-7 3 5.5 5 I 11.8 1 2.6 4x21/2 3 I 3 25 5 51/2 , 13.2 31/4 8.5 51/2 17.0 1 5.5 4x3 4.3 b 6 1/2 1 7.5 5 x 4 31/2 19.0 3 /Z 123 b 1/2 26.0 J 6 x 4 4 6� 8 7 3/4 1 36.8 41/4 243 13/4 45.0 1 3/16 12.8 ' 10 9 62.0 4 3/4 41.0 9 I 100.0 1 1/4 I 20.0 6x5 4 6.4 12 10 1 125.0 51/4 58.0 10 I 140.0 11/4 I 27.5 8x6 S � 11.9 Di stributed by: The ReliableAutoniatie . Sr nit zkIelrCo.; hie. , ..7' o- t e # . ;. {x,,t , ,' ` c • : 4 :- ..f .. ._'. p2... ,, t; 3 ,. " t, , -_ ` �i: �.., ,' t a r nw ., t u4,' ., r_y,nr y ,e-„ f o- R t ,�+t{' Y ,fSyr r r at: d'V , k � {.. o , t -, 71: Ml J } - t l • ,. - ipv� , „,,,,, -,,,.,,,f 0 ..,4:,.. on a f .� „ ,' ".� .H S TYLE ' -A. 11, 0 ., ( � 'M ,',17..:(4! rq+ t q, r` 7 r z d v , i A r 9ar f ': l �- "� tie. • rc r ' y 4F t ,• r. i T f 4 "h 9 fi X 14 G Tf M' x . r, ,'. �� F 1 , ''r� r Lightweight Coupling rods J ' f ! y ' P p r {. w„ . .1� l s g ' AMP fl } , � t t f i � ! " f r �'� t i , ' Y n r ',1i 4 sE � > A - ` lo ' -f7' ,,i-r �, ' t i . Uh if �eor'P Lif 3, ' Y m�' r,. - , ';•""'( rs? .:.• e t- •,..,' � xl M d �.!,( n fv ut°+�. - '�:. • :,,, , i 5+. r'r 5' A'' ' '� .,,,....,. ', .f. ' r ' . , ` 't ,l. o ',, ,, ,,..4%; .. '1 a. , .f, . i �' rY. S ,,,! df.. . � ,Y���- j f' rK STYLE 10 �, 4' ti , . ' M . , ��. _- - LIG HTWEIGHT COUPLING When low to moderate work pressures ! ' '' a ' are involved, lighter weight style 10 is an r:,I h. economical alternative to style 11. 4 • Deflection from C1 Dimensions Approx. ' ) Nominal Pipe Max. Wk. i Max. End Allow Z Wt. Ea. Size O.D. Pressure Load Pipe End Per Pipe X Y . Lbs. Inches Inches PSI' Lbs." Sep. In." Coupling ln. /Foot Inches Degrees 1 1/4 1.660 500 1,080 0 - 1/8 4 - 19' 0.90 2 5/8 4 7/16 1 3/4 1.5 1 1/2 1.900 500 1,400 0 -1/8 3 - 46' 0.79 3 1/8 4 1/2 1 3/4 1.6 2 2.375 500 I 2,215 0 - 1/8 3 - l' 0.63 3 3/8 5 1/8 1 3/4 1.7 2 1/2 2.875 500 3,245 1 0 - 1/8 2 - 29' 0.52 3 7/8 5 7/8 1 3/4 2.2 ____~ 3 3.500 500 4,810 0 -1/8 2 - 3' 0.43 4 1/2 r 6 3/4 1 3/4 2.8 4 4.500 400 6,300 0 - 1/4 3 - 11' I 0.66 5 7/8 8 2 3.8 5 5.563 400 9,720 0 - 1/4 2 - 35' 0.54 _ 6 7/8 10 1/8 2 6.0 6 6.625 400 13,790 0 - 1/4 2 - 10' 0.46 8 11 - 2 7.0 8 8.625 1 350 20,450 0 - 1/4 1 - 40' 0.35 10 1/2 14 2 3/8 13.0 Maximum working pressure, End load, Pipe end seperation and Deflection v luf are for Standard Stee pipe, cut Grooved. For standard Roll grooved steel pipe, Deflection and pipe end seperation values wil l be 50% Distributed by: Reti�abreAuton`a Sprutkiier' Co Inc.. Page 1 of 1 -V. ,3,Pitt°4 ,,... ';.„' .. ; :'':!:,. i ' ,.::.::i.?':-,, i F ro ` i� � ii '•''''•„ . f V � � � . �a��� .a r t g �€, r i ' -c ns._..� � vs -� i '; a,,Y rn `f s � „ , i' ` . a �, s 41 '* 't d '*`. 6 �' �' z It's mar than quality, it's a completed ^ 0Our s s ta n dard cart , s i z e a nd 1 . The be s t prod zn t busines 'quality sy m. Eveiy pro duct i s 5calo -c by pr cat des , fie best >g th i m to Aprecrse s�nda chan the way a who industry it. he S C l G reel c r i n spec te d : twrc and a te -All g m y Wi thkeasier ' arty pi pe,v il ve o r fittrn { u p , to a h ; } ; materialsF aInd s dimen s i ons mee sh i ¢ in g a n d handling srez Mull five ye en �prop e rly installe -� t t ! ' i � . `t 2 i l, T a i� a .,',: ^` a- eT' , "'' .> ii Y s ?s f refevantAlydS or' AST lkf , s t an dards , trac king and r eord e ring And easier and oper if f i due toA , .. f ., r v s . „� �° - : F� § r i .. M ;., x tr a ` � ` ^ so.__ ! r`; > r l a - s a nd the w process is ISO 9€102 ! t j w ar ehou n i l ess s tS CI P defects in m - - d f , f s or orkmanship certified .SC! Quality Plus meads our . { Pal y te rn it.eas ' ` S m i tl i Camper !t even pays s ": ' o r s- - i , . a .r r i tt '' ," '� _ _ : 30-year r ep u tati o n ' i 'ever before for $SO t t h e.inst al li g d s° f o { all ' is buil . . - yea � ya u ` to lo .i � a 't t contracto to o the � � � 9-1 'i 5 °` `5' x .' F x ;;' S ice!. �R��i1 ' �+/ r "'�` qs ,� F L f e?' �n� J RCe C ' W co p 't" _ °nM 3 (� � �; op erating k �! C A cif ins tallati n x w 4E intV. eery 9... f^I� 4 e f i4 - fl.kts i L h �.., $,r C � °' "` r fully traceable �nd impr �.� i k iii t iti T ( ) � { i �i tyro �.w �+, $° product" i { :'s r�� - ,,',',::':.'-:'.:'• ar �1iRRAfYrY Ffift l"C �E flF T ii c ,i serve € £� l'"'---. i „ _.� r te,. http: / /www.smithcooper.com /about files /about sample.gif 5/19/2005 SMITH - COOPER . 44 3t * INTERNATIONAL Ductile Iron Threaded Fittings * ALL FITTINGS 100% AIR TESTED *ANSI B16.3 C' US * ISO 9002 MANUFACTURER * ASTM A536 4 <i› LIS * LISTED /APPROVED AT 500 PSI * ANSI B 1.20.1 Ductile Iron 90° Elbow Ductile Iron Coupling Fire 35E Size A Wgt Figure 35CP Size A Wgt - 1/2 1.13 0.24 1/2 1.38 0.18 mi * 3/4 1.31 0.40 3/4 1.63 0.26 I 1 1.50 0.64 1 1.75 0.44 I 1 -1 AI /4 1.75 0.95 A 1 2.00 0.54 1 1 1/2 1.94 1.24 1 -1/2 2.19 0.71 I Ilv 2 2.25 1.74 2 2.62 1.15 2-1/2 2.70 3.28 2-1/2 3.00 2.29 Ductile Iron Reducing 90° Elbow Ductile Iron Cap Figure 35RE Size A B Wgt Figure 35C Size A Wgt 3/4x1/2 1.22 1.20 0.33 1/2 0.87 0.15 1 x 1/2 1.36 1.26 0.44 _ 3/4 0.97 0.22 1 x 3/4 1.45 1.38 0.53 I 1 1.16 0.33 1 -1/4 x 1/2 1.53 1.34 0.64 E 1 -1/4 1.28 0.54 1-1/4x3/4 1.63 1.45 0.75 i 1 + 1-1/2 1.33 0.68 1-1/4 x 1 1.67 1.58 0.77 2 1.45 0.96 '-A -I. 1 -1 1 -1/2x1/2 1.75 1.52 0.90 2-1/2 1.70 1.80 i e 1 -1 /2 x 3/4 1.75 1.52 0.95 ' d 1-1/2 x 1 1.80 1.65 0.99 Ductile Iron Hex Bushing ' 1-1/2 x 1-1/4 1.88 1.82 1.14 Figure 35HB Size A Wgt 2 x 1/2 1.97 1.60 1.35 1 x 1/2 1.06 0.22 2 x 3/4 1.97 1.60 1.39 1 x 3/4 1.06 0.18 2 x 1 2.02 1.73 1.58 Nimowmi t 1-1/4 x 1 1.19 0.31 2 x 1-1/4 2.10 1.90 1.62 A 1-1/2 x 1 1.25 0.53 2 x 1-1/2 2.16 2.02 1.67 1 -1/2 x 1 -1/4 1.25 0.35 2-1/2 x 1-1/2 2.51 2.16 2.32 2 x 1 1.38 0.75 2-1/2 x 2 2.60 2.39 3.01 2 x 1-1/4 1.38 0.69 2 x 1-1/2 1.38 0.62 Ductile Iron Brass Seat Union Figure 35U Size A Wgt Ductile Iron 45° Elbow 1/2 1.88 0.47 Figure 35F Size A Wgt MM. • A 3/4 2.00 1.08 ii 3/4 0.98 0.33 S■•• l 1-1/4 2.50 _ 1.54 ` 1 1.13 0.48 nil v 1-1/2 2.62 2.03 ` 1-1/4 1.29 0.73 2 3.12 _ 3.15 4 1-1/2 1.44 0.93 i o 2 1.69 1.55 Ductile Iron Tee 2 -1/2 I 1.95 2.70 Figure 35T izS a - A Wgt ® --A- -* - 4--A- -► 1/2 1.13 0.33 Ductile Iron Beam Clamps 3/4 1.31 0.50 ■ o Figure 35SP L- 1 1.50 0.85 °' Size A Wgt I A 1 1.75 1.30 i 3/8 0.75 0.31 1-1/2 /2 1.94 1.63 1 /2 0.75 0.54 2 2.25 2.63 _ - 2-1/2 2.70 4.55 SMITH - COOPER INTERNATIONAL Ductile Iron Threaded Fittings * ALL FITTINGS 100% AIR TESTED *ANSI B16.3 C 44) US * ISO 9002 MANUFACTURER * ASTM A536 4 44 1 0 LI * LISTED /APPROVED AT 500 PSI * ANSI B 1.20.1 Ductile Iron Bull Head Tee Ductile Iron Reducing Tee Figure 35RT Size A B C Wgt mmrimall 1 3/4 x 3/4 x 1/2 1.20 1.20 1.22 0.46 Figure 35BT ° 1 x 1/2 x 1 1.50 1.36 1.50 0.70 1 x 3/4 x 3/4 1.38 1.31 1.45 0.68 1 x 3/4 x 1 1.50 1.45 1.50 0.77 Size A B C Wgt 1 x 1 x 1/2 1.26 1.26 1.36 0.66 3/4 x 3/4 x 1 1.45 1.45 1.37 0.68 1 x 1 x 3/4 1.38 1.38 1.45 0.73 1 x 1 x 1 -1 /4 1.67 1.67 1.58 0.97 1-1/4x1/2x1-1/4 1.75 1.53 1.75 1.04 1 x 1 x 1-1/2 1.80 1.80 1.65 1.14 i-1/4x3/4x1-1/4 1.75 1.62 1.75 1.09 1-1/4 x 1 x 1-1/2 1.88 1.80 1.82 1.43 1-1/4 x 1 x 1/2 1.34 1.26 1.53 0.81 1-1/4x1-1/4x1-1/2 1.88 1.88 1.82 1.52 1-1/4 x 1 x 3/4 1.45 1.38 1.63 0.90 . 1-1/4 x 1-1/4 x 2 2.10 2.10 1.90 2.00 1-1/4 x 1 x 1 1.58 1.50 1.69 1.03 1 -1/2 x 1 -1/4 x 2 2.16 2.10 2.02 1.94 1 -1/4 x 1 x 1 -1/4 1.75 1.69 1.75 1.10 1 -1/2 x 1 -1/2 x 2 2.16 2.16 2.02 2.00 1 -1/4 x 1 -1/4 x 1/2 1.34 1.34 1.53 0.87 - 2x 2 x 2-1/2 2.60 2.60 2.39 3.67 1-1/4x1-1/4x3/4 1.45 1.45 1.62 0.96 1 -1/4 x 1 -1/4 x 1 1.58 1.58 1.67 1.10 Ductile Iron Hex Reducing Coupling 1-1/2 x 1/2 x 1-1/4 1.81 1.56 1.88 1.37 Figure 35RC Size A Wgt 1-1/2 x 1/2 x 1-1/2 1.94. 1.66. 1.94 1.42 � 1 x 1/2 1.69 0.40 1-1/2 x 3/4 x 1-1/4 1.94 1.66 1.88 1.42 I 1-f i 1 x 3/4 1.69 0.38 1-1/2x3/4x1-1/2 1.94 1.75 1.94 1.47 A 1-1/4x3/4 2.06 0.53 1-1/2 x 1 x 1/2 1.44 1.25 1.69 0.97 r I 2 x 1 (not hex) 2.81 0.53 1-1/2 x 1 x 3/4 1.50 1.44 1.75 1.14 I I I i 1-1/2 x 1 x 1 1.65 1.50 1.80 1.14 1-1/2 x 1 x 1-1/4 1.82 1.67 1.88 1.47 Ductile Iron Cross & Reducing Cross 1-1/2 x 1 x 1-1/2 1.94 1.80 1.94 1.52 Figure 35X _ Size A B Wgt 1 -1/2 x 1 -1/4 x 1/2 1.41 1.34 1.66 1.03 1 1.50 1.50 0.97 1-1/2x1-1/4x3/4 1.52 1.45 1.75 1.10 -- 6 1 - /4 1.75 1.75 1.59 1-1/2 x 1-1/4 x 1 1.65 1.58 1.80 1.31 _.. _...._.._. 1-1/2 1.94 1.94 1.89 1-1/2 x 1-1/4 x 1-1/4 1.82 1.75 1.88 1.52 T 2 2.25 2.25 2.93 1 -1/2 x 1 -1/4 x 1 -1/2 1.94 1.88 1.94 1.50 i ' Figure 35RX i-1/2x1-1/2x1/2 1.41 1.41 1.66 1.14 e 1 I Size A B Wgt 1-1/2 x 1-1/2 x 3/4 1.52 1.52 1.75 1.23 ---- - - - - -- 1-1/4 x 1 1.67 1.58 1.25 1-1/2 x 1-1/2 x 1 1.65 1.65 1.80 1.38 1-1/2 x 1 1.80 1.65 1.48 1-1/2x1-1/2x1-i/4 1.82 1.82 1.88 1.50 2 x 1 2.02 1.73 2.64 2 x 1 x 2 2.25 2.02 2.25 2.18 2x1 -1/4x2 2.25 2.10 2.25 2.31 Ductile Iron Plugs 2x1-1/2x1/2 1.49 1.41 1.88 1.50 Figure 35SP Size A Wgt 2 x 1 -1/2 x 3/4 1.60 1.52 1.97 1.61 1/2 0.94 0.10 2 x 1-1/2 x 1 1.73 1.65 2.02 1.65 ■. 1 3/4 1.12 0.18 2 x 1-1/2 x 1-1/4 1.90 1.82 2.10 2.03 A 1 1.25 0.28 2 x 1-1/2 x 1-1/2 2.02 1.94 2.16 2.37 1 -1 /4 1.37 0.50 2x 1-1/2x 2 2.25 2.16 2.25 2.53 1-1/2 1.44 0.70 2x 2x 1/2 1.49 1.49 1.88 1.50 2 1.50 0.90 2x 2 x 3/4 1.60 1.60 1.97 1.67 2x2x1 1.73 1.73 2.02 1.91 2x 2 x 1-1/4 1.90 1.90 2.10 2.05 2x2x1 -1/2 2.02 2.02 2.16 2.11 T r " .J, � .,a : .M +r {ti. ,Tr 'Il i�"+} i ,.. t � j + C 3 - ftS.7��J<? i c sf v. v 9 r r � r . �1;,#c+ a ' F 5 " 3. Y7 dL S nt F jJ , ib'v' i r g %'O � „k...l ' ` Y . ,. f = x r t "i'L +. -+lFt` 'S '�a!' ,. -$ `. .. �'� *rt, �+..F ... - ( �s 4 't?; ,iG e '. aAir` tt w . ( `�r•d7. >w�; s .'" - - y iS1r i `,--4 z ; +' .• "i?4y '., F & h ra . f i $ r ;fi - 7t `.��.Yt ,J . FS•`;y at V ., rC er go- . 7' , v �r`*�+ f . 3 l - , l .;¢ ry..' t.a 7t ,,, i ' . , 4r t . .:.: '. Y. 94 yv F� '�v ,. , �,�'' f;x ' t . t . _� ti' 4 i iL r i r 5. nz 1 „" - ,4 •( -,1,',,g',1:;;;:--,,*-.`!„. �, , r r. c .. i a 2 ' Sr '� h 5 a � �.e� rL{ 7k � `l� �l ° i 1 el � z �t 7 "'�'" T if 'n 4 4 1 �'L it ,� , � y �v h - 4 ' { -V T T ket � "z �t fl �`� , y . � a i. ..'44'... � r � y � r r f c `i » '`',?•`-''`. a . yl f 'd5 �”, n. ✓ ' • i i r . *A f t 't'� -ti >Q' .. `�" t � 7 A rf N ,�;� y � . Y ; , fi t t �' t � , . v � ' � rf�r?+ , � u x -, ; - '4', 'ry r ati ' �hk + •f�l vY f r + �!' !'�� r k� 4 ti t . + ^ 1 i q � ..t S.t J - =.;:-.11,5:.,..,,.; ' �, -° ( ' r t r "F: y F yy Lt r „;, ' z. 1::c'''' i to 5 It`„,;,::, ! 1 a 4 T , a^; r f f j�' ` t y ' a' r ,t ! • ; tS rt ( (' '' x w• 1 �1. ! �. c r 3r tJ 3 • i , �t p f 14.40.,,, .. ,•,;. A 1 ' . - ''''' �r {.. 4 5 .,? G :- . .o �" ` 4 F - x {� e ty . J ~ ' j k r Y f 1 1 ; i ..w E t} 47A; i S � 4-' ♦ y s v x + v � - ; ,, , , ,,•'•• F � > � . �� . � � { � r t 4 r+s^ :h s av*� : a~ o ' T r .. 1,..,,,\,',',."i•'''.4.1' : _ G , �},,` k u° r•1+ ,r. x. 1 t tt” >h - ,1' .;f.. t s t.. ; '� {' . : .,., ‘'L' ,... ::*: . i i4 t` 1 '' -ay, y �RSi y.. 4 ` �V: „ , , , : ' , : ' ‘ ",•; ' ,i . , C r � - S. ,, �. Y , ' ,.,..,-; :*: •, , :: : ', ": : - ,; - 1 „* v. + �,u. �r , : �+, j o r 11 ..--A ..1 • = ' I � a P � .ir. r: :' f t 1 44 . . k . "I. 1 b i i t y r .s t F J -;,r v „QgyC('�`� f r µ r ,;. F t '� k 1 f t ' 1 } . ! '' ' ` A , N 7 I k (. t k -t Y t + I P �� ( 1 � t r ' tk c r _ � g t 7 t >U. J� nt, 1 , I, r A „ k` _ k . a? ' r ' r p.., ; J J f ' �'k.•?�' kj v} F , ""'ac,rt �) q t � � v rr ^' . laa y ,.. s ' 4 T i I y+1- Y ,•tY f • : 1� i c 'l X � 1 �a <�''.zp�2 x s, r � r� � 'r r ; . • z c t y ✓ "I'µ r ��'tj �t_ « {. • M q • : '; ` , ; , : , ,- -: ;',,' : :,....,' , F , ' - ' v 'G A � 1 w •``'� 1n �� � -:'.-1 ° § f e ,.. r I i ; a ”' 2 J 'x� .,,� I+e , . s I k. # e r . 'k ak, 'h > , r ,. h ,t -;:',:-',•:t y s 7 + -,e ' kK', , ,, ! , r" �'Fr � x i !'r� Y � ', eft � 4'„;,:i.,.. ` i T 4:„'',,:',.,•1;',A1;: r i s ri '+''_ ° i . ^Y' }� o-e � r' � � ,*:;.•-:,,,,•,',,, ! u �,gsc�v7 r e � -' s n {. rr n � -m z''3 _ ,,,J r z n � .t.. :k � '` , w th d �' k #'k + +.: ry ,°5y, �,re ' 1 . ,.: ,, � a a A" f , 1 ' ' . I . r � � . �i§ a wn r`"t .lr C 4 '%,.. .--,. w+� r` � a . � � }r , ".v..4' � '� ,. u � - , r+ 1� t ' +t 4 1' V i rgv •- +� . 2''rr�"'.� �• • �.s!: ' C i t4 7 , k .. * t K i • ° �.: - t , i t'a � - r � T „ I r l " '1. t Oill es � Pistoii 4 ` ' ... 1 "' fit' . + �� '� • ® �e + _�1. - . i J 'ti 1 � L. n 1 ; r •-• -11 �' • • •r ( / o ff_ 6 • i i i J ! t :� ri?.7 s.� • , ..H ' •}f }OU I.JU ,,... • + 1 A f h t } ii f ^ -.t _ IA IU x ,� t,+r e d t x ' »+ ' r , i'+ as rYy I t at y of rz,... I s 't a4 ',f`'. fr. i e z '' ' '' . ... cl 1 ' r ' . r �'� ^ t` " G! l'.4":;•:-. r t m y ._ r{ , �w , t . { r t , +i r r, � .L 5 � Fk Dry.Sp { s A � � I � + r�nkle Syst '.✓ ��z. i.. � sR'�r A . S :.� ". � a te ,. : t' r , !' r r ` �t 4 . r 3, • J .w ;� t< - .: r 'a lt t , t � ; z • .. v ] a a i u a •- 7 d :e u ,1 'b»}k , w Y . .d x' : t +1a is £G k c k , 9fi i Y a d <� tJti 3 x X:t ': f t } y ,aid' xy -,� Yt � l 4y lC f t:!� t * ry a Q`4 {� i ^l� ,� e t xr i't r'fi r l: , 5 ., ai a d } e r � � . ro '-';',,,'"'';',..'!,7:%,1^..-, .. t¢' , N -';3a C > �< c i,.,,r 4 " G, a 9 .r. (� , FtIt: �,' a h �k ri1,5 a zt::: u a fs i n r ,t., +, " . . 3 tr. t X �. 7 ' �' { .•rl+ '• v'. '' a s kW y t . i` r • . i �� • v ,t GA o C `" 1e :,. m,e r vx i � .. j t ,'N: i [ ? t4 ■s r + ",'4':','•'''''•': ` i ' `.� tt. }" F � . � 4 °S r rt �i iy' P � ( a '• rl. r" t r t ay '�yg'r t` p r ,t u p r 3 4 r s : ' r r c w F ° y v r gat +i s _ . . #..} ' a ' 1 t r+ •z ' " x - ' L i Y v aY r . �i.:•t.a �. . .y ` ."t -f n tt. ~�{,� -� .t,°< i P.. y.3'r,�'' C ar " r `F x x 1: ., 3>, ,,.-i! h } f xt r 7 w d ts< ..t r,.:f.t `n..,,.. „ ... ^• ... .rd' ,x4a. �. 1: r `G,. .+ .4 Y3:r • _ Y: :'.L .k.4a k - �i,.iaa .. r. ..dy .{1' . �. 1. .�,. ti ._ i . ., .. Piston t i ' t ®III �S� � CJ 4�af. _, . 7,._ i Features • Motor mounted, no belts and pulleys �4 . • Oil free air, no lubrication required o-,' , ,1k , , • Corrosion resistant internal parts° • Compact, lightweight and easy to install '= • Regardless of Cause Warranty '°' - - u s = " Max. Gall CFM yank Mounded I,') ; , Z. 1.415117 . &C - 0 And With Chedt * �`' >..,... •h w. I m T V a l ve (lhnk She +Gallana) To Pump Motor Data Compressor sitch yank units are wire I o s x for 115 volts \•� In 30 M � � ,, 150 A H P., 115-60-1 2LAF-10-M200X 2LAF12 -M200X 2LAF11T -M200X (12 gal,) y t .TS, . .3t8/4r1QM300)Q .i; 4iL35ea.'.tq i ' = , r� ,Z. 300 -^ .c'r ` ='M ® 1/2 H P 115 -60-1 4LC &10 -M400X 4LC &21 M400X 4LC &11T -M400X (20 gal) G.' +r.: . �1: ,t -1 .11 . ': J ° - ' . ... ; • '--... / ':' ..- 6---- . 7 400 ® A H P 230/460-60-3 5LCA- 10 -M502 �, ti ,.P S . ,.;,^. l y•. r 6ffii - .; a . : K O rzt: Ri a?4'7 ;IFi ,<.;; rr 600 5.9 1 H.P. 230/460-60-3 6LCF10 -M617 - M1 •• I I x::ija W • ��O,2,i l : i . 04700:417674- t,. 11.1tl lar rl t 7e f .Mis; >l " � ` 800 7.9 11/2 H.P. 230/460-60-3 7L0E- 10 -M702 - Air Capacity of a System ? u Capacity of 1 Foot of Pipe. (Based on actual internal diameter) �-' DIA}METER GALLONS DIAMETER GALLONS � _ t r n 7 , , � } . ,.,1 TANK PACKAGE ASME. coded tank mounted . > kk ?t!c !i" .,✓ ....l ;u' Tr t .,s i, r i:1.F, 3 t• a ".3 �/. In 02 8 3' /z In. s13 compressors include gauge, pressure switch*, shut off F'l'' 1,.z' f ,� f r �i s' . . Z � ,! _q 0 �, % .� Y , ; ytMY valve, drain valve, check valve and safety valve - 5 i n 1.040 'Minimum pressure switch differential is 10-13 psig- 1' /. ln. 078 �,� P 1,„ iti. , ° 7 - �'*� 1' t'_ti , t' � ��a� ~ ?' ' 2 in. .174 8 In 2.66 Dimensional Data I ] r q1 s t '� t : : x r ,•.uh,t7 r, £t: L' i:-` Model No I A B C Pipe size ' =,�: .w„ .,,.J T a� 'z L _> Yx ss 1 LAA 11 T M 100X 18 50 q , 8.12 17.28 '/. NPT Source: NFPA Sprinkler Systems 1988 Table 5232 :r; ":c' .1 . "1:_.%+.Cri .:y` " ry ° .i `t :,.,' • U Laboratories, S� - y 3 LBA 11 T M300X 26 00 13.00 20.75 `/, laboratories. r . r r ;, r +i'>�uis �,. C ertified Models '°'`�' ® � Inc" Listed 5LCA 11 T -M500X 33.00 16.50 26% %, •w MEGR Power -Operated Pumps MP144a Model No. D E Pipe size "" k Air Pumps (Motor- -Pump Units) 1 LA. 218, 3LB. 4LC. 5LC with suffix letters and numbers ending - 7LDEfl •3S:. ,U ' .; x • r >�' .: <:, in M100X M200X. M300X, M325X, M400X. M500X or M500oX 11-IA 2HB, 318, 41/C, 51-1C with suffix letters and numbers ending in M100X, M200X. M300X, M325X, M400X. M500X or SIDE VIEW FRONT VIEW M5000X 31.61 with suffix letter and numbers ending in M326X or M327X QDFr2 Lqa la Component - Painting Equ a. u,,,,, Air deli= a ?j:: Equipment. , _ Compressor. Vacuum Pumps E75450 (�`, c ,A tl Compressors Models 11+A, 1 LA 2H8. 2LB, 3HB, 3LB. 4HC. 4LC. 5HC, 5LC followed by any . tw B '�f` f "` �k • - sa - '.^ � letter A to L l followed by two digit numbers 00 I C incl., followed by any letter A to Z ind.. ty 5 t _ '1 r ,w followed by letter M. followed by thre ee digit numbers s 100 to 699 incl., followed by letter X. V a Z V. x- : -.fit' . pM rl 1 1 ' t Guide Na 224.0 ' ! `+ .* . � � --a- y Class 3811 r-• i .r..•:..r i. 4 Air Compressors LA37697 — ' C Piston pumps. stationary, compressor or vacuum Series ILA, 2LB, 3L.B. 4LC. 5LC, 1 H - - A 2HB, A - 3H8. 4HC. SHC. 5VS. 5VD, 61.0.6HD, 71.D, 71-10, 1 VA, 1 VS. 1 VB, 4VC, 4N/S, 575v max. single and three phase. 50/60 Hz. 2hp max. Series followed by suffix numbers and letters to form model designation or (XXXX) replaced in ea 1 (�,, Serves to loan model designation. ! � j.1 'I �•. '•.I6 :0 iit i iI G ast has more literature o oilless piston air com .� „.4 , r Call or write for ''' �- t g. . Air Compressor Catalog No F -10 Compressed Air & Vacuum Systems H -10 Y ` ; .., . . 0 ,. ,r: MOTORS — All air compressors shown in this brochure are open motors. Single 44i-it . > : < phase motors have internal thermal protection. Dual voltage motors are shipped pre - 1 „,. „ ' f, ` � `' i wired for the higher voltage (except all tank mounted units are wired for 115 volts). CT Compressor mounting bracket comes complete with all the hardware and adjustable stainless steel straps for mounting Gast tankiess air compressors ,0 .','' to all sizes of riser pipes. To order, contact your w local sprinkler supply Q company or your local Gast distributor and ask -. "z' 9 for Gast part number 1 .... AK289. a .,,,,, • „ I It :, , • 1 K. � 4 k . ► .�� .. /. 'ti. i � ti, . J ...:-. — ' li ' - I ...1 4: .1;''',- I compressors have inlet filters and a B ARE /MANUAL a ir corn TANKLESS /AUTOMATIC air compressors have inlet P ( filters, a safety valve, pressure switch', check valve, - safety valve. - tubing and fittings. - Minimum pressure switch differential is 10-13 psig on most models. The 2LAF- 12 -M200X has 6 psig minimum differential_ Dimensional Data ' Model No A B C 1 y � .a lie 1 LAA -32 M100X 5 14 1/4 _r i` X87373 Aii �y ✓,: ++,,� F'' �' '! 11 -ar a��9jju''. � `� of T +2, x r A ���� i k i�Q •.�.A` ,Ffi ...�- :j. ' � :.AFL' :Lr ;•Tdrr�i: e. „ , 3 i s ��!"-4, �— T 3LBA 32 -M300X 5' /e 1 ms 15' { q '/` N.I FRONT VIEW t {y ° ,1° J`P' ' � . ..d ...�: i:t. ; :a SIDE VIEW 5LCA- 22 -M500X 8% 161/4 121/4 V. C MAF�573 "'r4 , _ B , aY JV - :;' Model No. • D E F EIMM '31r7EDE16= 1V(700XIM 2334 1230.- MME -zosalo x .� . ao9 Accessories: ;a :: rs �'� _ s � f>! 1 12_ ' , D Part Number Description �” t `flflii�i :v p z = :cCtiec Ya14a14 /4.: —7 , :` - , ���■-- AJS50A Check Valve W NPT Female arm ® " .0— srm• anl 41 A - '. Rise liifoiiirttirig *: -x A 1 * TOP VIEW FRONT VIEW A K620 Pressure Switch E F (6 PSIG minimum pressure drfferential) is .°" 1: Pressure• Slwitctr<a v 147 == s ; ,. i - , , -, �r 4E1¢- la PSIG:ininirnurNxcesuMOII ferential iZi41 AF631 Shock /Isolation Mounts 1/4-20 thread (both ends) • r-.AF633 : StioCkltsoiatf ri fv uiit , G',e 14,Kea (float en Refer to NFPA 13 Chapter 5 -2 (Dry Pipe Systems) for limitations and requirements of air supplies. • 3 ' . y � � •, � � . s 21;'''',4`; ' 4. 1 . ,'` ,1', ..•'.:1 1- ` - '`.' , , - ...;, , _ � .� � u f W r .. � • h Y S t t 1 a j & is ,1 u r ;.: ry . ;.:.''..?:;:,',,,9,z,'-.,i.';'":" " F s 5 a r . . �i4 `N, v b e a 6 , h . , i; t, a '4!.� t - ,� .' ,t•-• { . _ ‘...,1.-k•,- 4 .dl r . #+ .� 01'9 k� : C •:-;9''`..!•-•:'' •...P Y , t Ti 4N 1r 1 ! 9 { c�, .� . : f :' • ! ,..„:„.4 f i d ' , 3 •;,‘„.• � ■ fr} G „r S � 7 1 � p' ,1 :^ C . t; t t t .d ' 1 ';'.a 1 t' r vii, Y :::: 1� F p' YOUR WARRANTY '-• y' • REGARDLESS OF CAUSE, if a product you buy from this catalog does not work right, Gast :�� ; will repair or replace i t once, at no charge, for up to one year from the date of shipment from the factory. In the course of repair or replacement, Gast may send you written recommendations on how to prevent a problem from happening again. Gast reserves the right to withdraw this warranty `- if you do not follow these recommendations. Customer is responsible for freight charges both z to and from Gast in all cases. , ,ii s This warranty does not apply to electric motors, electrical controls and gasoline engines, which Gast obtains from other manufacturers. A motor or engine carries only the warranty of the ,' company that makes it. -',•••, 11 x % .. THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, WHETHER WRITTEN, ORAL OR IMPLIED, INCLUDING THE WARRANTY OF MER- i CHANTABILITY AND OF FITNESS FOR ANY PARTICULAR PURPOSE. GASTS LIABILITY IS IN ALL CASES LIMITED TO THE REPLACEMENT PRICE OF ITS PRODUC GAST _ SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES, WHETHER CONSEQUENTIAL, rs { INDIRECT, OR INCIDENTAL, ARISING FROM THE SALE OR USE OF ITS PRODUCTS. ! Gast's sales personnel may modify this warranty, but only by signing a specific, written de- scription of any modifications. n w t+ ;1 . S ar . '.., k r t t - r-c 1 r t • y'} ;'' y � r 1 ,'.•• *: - r,',-:‘ i s t ,- , 1 ! 1 - 3 ' i l l t r ) 7 1 � J a'i J 7 r� �l a �' �. ,..t''"' _ f 1 t- JJ � .. L 7 1 4 • • f _ • 1 1 t t � . � . 1 d' Y �• ; .` -3 y � v„ ryry1 _ `t� t � 1 _ '0 - r4 �' } } YC � . 5a 8 ., T • I / � N • s x . f ' .�•,q,k } ry k , -„,,,:::.--,-1,,!.'„'„,',„-- d c4 r ' :.. ; Y r S , r h t \ . / ,y. ' 1 • t 7 , x Y h , t t - 1 J i 1 ;. t 5 d-w Y �. * .` -� L . i i _ { . {{ �� _ 1 , ! t . a� +.1,-,.4 � •"ray"' tr tl. , t � ,i, • a 11 .,,� Z :: t t ` Y I ",1 r, ,, f 0 Tt / /�` f 4 yj 1 s �Y : i t 3 , r � f.;'..2-7.-!:: � '•, J4 � � R •.Zf 'rt�j.• ,• $fir'{" . � ry a ll�`� � I '� 7"�_t .r ,�, a �C�.'� � j' F. 0 � . • 5 ., -� . - , ,Y 4 . - .3h '1' I t ' i � t. : yw :'r.c k..4 ,,.r � - s .„L +� , te o -,-24-.2. " ' S -gi. r' "". q 4 . —t � .s 4 w = 4 � � a -�' * ri m t ? se '4' � . �(, 1 } t • , � y � y y � .. : .�h( 4 1 � +c� � . � r ` `K n l t.Z s, , 4-9 d�!_ w :+t. p�iY52�7° Awo-i��k1 r •hq . tf t om~ . r • . x4 - OSYSU -1, -2 OUTSIDE SCREW AND YOKE VALVE The Symbol of Protection SUPERVISORY SWITCH UL and CSFM Listed, FM Approved, NYMEA Accepted, ' CE Marked `, Dimensions: 6.19 "L X 2.25 "W X 5.88 "H 15,7cm L X 5,7cm W X 14,6cm H ''s ()Pam?, Weight: 2 lbs. (0,9 kg.) cc .. Enclosure: Cover - Die -Cast -= -- Finish - Red Spatter Enamel Base - Die Cast Zinc All parts have corrosion resistant finishes. e • Cover Tamper: Tamper resistant screws, y ,1 Optional cover tamper kit available. .,, \ , Contact Ratings: OSYSU-1: One set of SPDT (Form C) OSYSU-2: Two sets of SPDT (Form C) 15.00 Amps at 125/250VAC it ;f 2.50 Amps at 30VDC resistive 1 a Environmental Limitations: • NEMA 4 and NEMA 6P Enclosure (IP67) when used with appropriate watertight conduit fittings. • Indoor or Outdoor use (Not for use in hazardous locations. See bulletin no. 5400705 OSYS -U -EX 1 for hazardous locations.) • Temperature Range: -40 °F to 140 °F (-40 °C to 60 °C) Conduit Entrances: � `:�' 2 knockouts for 1/2" conduit provided Service Use: Automatic Sprinkler NFPA -13 OSYSU -1 Stock No. 1010106 One or two family dwelling NFPA -13D OSYSU -2 Stock No. 1010206 Residential occupancy up to four stories NFPA -13R National Fire Alarm Code NFPA -72 GENERAL INFORMATION The OSYSU is used to monitor the open position of an OS screws and hex keys are available. See ordering informa- & Y (outside screw and yoke) type gate valve. This device tion on page 4. is available in two models; the OSYSU -1, containing one OPTIONAL COVER TAMPER SWITCH set of SPDT (Form C) contacts and the OSYSU -2, con- A field installable cover tamper switch is available as an taining two sets of SPDT (Form C) contacts. These option which may be used to indicate removal of the cover. switches mount conveniently to most OS & Y valves See ordering information on page 4. ranging in size from 2" to 12" (50mm to 300mm). They will mount on some valves as small as 1/2" (12,5mm). TESTING The OSYSU and its associated protective monitoring sys- The cover is held in place by two tamper resistant screws tem should be inspected and tested in accordance with that require a special tool to remove. The tool is furnished applicable NFPA codes and standards and /or the authority with each device and should be left with the building owner having jurisdiction (manufacturer recommends quarterly or or responsible party. Replacement or additional cover more frequently). Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146 -4161 • Phone: 800 - 325- 3936 /Canada 888 - 882 -1833 • wewv.pottersignal.com PRINTED IN USA MKT. #8820004 - REV P PAGE 1 OF 4 12101 . OSYSU -1, -2 P ~ , POTTER OUTSIDE SCREW AND YOKE VALVE The Symbol of Protection SUPERVISORY SWITCH FIG. 1 SMALL VALVE INSTALLATION - 1/2" THRU 2 1/2" (12,5mm THRU 63,5mm) SIZES THESE SWITCHES MOUNT CONVENIENTLY TO MOST 2" TO 12" OS & Y VALVES. THEY WILL MOUNT ON SOME VALVES AS SMALL AS 1/2" (12,5MM). J -HOOKS MAY BE REQUIRED ON VALVES WITH LIMITED CLEARANCE. OWNS UMW MINS IMO .r SLOTTED MOUNTING HOLES r MAY BE USED FOR FINE ADJUSTMENT OF SWITCH ON BRACKET CLAMP BAR �� (� BRACKET �v., Lam. % ."..•7 CARRIAGE BOLT W ,_/ DWG. #979 -3 • SMALL VALVE INSTALLATION 6. Remove the OSYSU. File a 1/8" (3,2mm) deep groove 1. Remove and discard "C" washer and roller from the trip centered on the mark on the valve stem utilizing a 3/16" rod. (4,8mm) round, non - tapered file. Round and smooth the 2. With the valve in the FULL OPEN position, locate the edges of the groove to prevent damage to the valve OSYSU across the valve yoke as far as possible from the packing and to allow the trip rod to move easily in and out valve gland, so that the trip rod lays against the non- of the groove as the valve is operated. threaded portion of the valve stem. 7. Mount the OSYSU with the trip rod centered in groove. 3. Loosen the locking screw that holds the trip rod in place 8. Final adjustment is made by loosening 2 screws (see Fig. and adjust the rod length (see Fig. 4). When adjusted 1) and sliding the OSYSU on the bracket. Adjustment is properly, the rod should extend past the valve screw, but correct when switches are not activated with the trip rod not so far that it contacts the clamp bar. Tighten the seated in the valve stem groove and that the switches locking screw to hold the trip rod in place. activate when the trip rod moves out of the groove. NOTE: If trip rod length is excessive, loosen the locking 9. Tighten the adjustment screws and all mounting hardware. screw and remove the trip rod from the trip lever. Using Check to insure that the rod moves out of the groove easily pliers, break off the 1" (25mm) long notched section (see and that the switches activate within one turn when the Fig. 5). Reinstall trip rod and repeat Step 3 procedure. valve is operated from the FULL OPEN towards the 4. Mount the OSYSU loosely with the carriage bolts and CLOSED position. clamp bar supplied. On valves with limited clearance use NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT J -hooks supplied instead of the carriage bolts and clamp THE STEM THREADS DO NOT ACTIVATE THE SWITCH. bar to mount the OSYSU. THE SWITCH BEING ACTIVATED BY THE STEM THREADS - 5. Mark the valve stem at the center of the trip rod. COULD RESULT IN A FALSE VALVE OPEN INDICATION. PRINTED IN USA MKT. #8820004 - REV P PAGE 2 OF 4 12/01 OSYSU -1, -2 ® OUTSIDE SCREW AND YOKE VALVE The Symbol of Protection SUPERVISORY SWITCH FIG. 2 LARGE VALVE INSTALLATION - 3" THRU 12" (76mm THRU 300mm) SIZES 3" THRU 12" (76mm THRU 300mm) VALVES BRACKET USE CARRIAGE BOLTS. BOLTS MOUNT ON INSIDE OF YOKE, IF THERE CLAMP BAR IS SUFFICIENT CLEARANCE. CARRIAGE BOLTS SLOTTED MOUNTING (2 REQUIRED) HOLES. MAY BE USED ROLLER FOR FINE ADJUSTMENT P GROOVE OF SWITCH ON BRACKET. fr / +� YOKE ` VALVE STEM • t TRIP ROD DWG. #979 -4 GLAND LARGE VALVE INSTALLATION (9,5mm) round, non - tapered file. Round and smooth the edges of the groove to prevent damage to the valve 1. With the valve in the FULL OPEN position, locate the packing and to allow the trip rod to move easily in and out OSYSU across the valve yoke as far as possible from the of the groove as the valve is operated. valve gland, so that the trip rod lays against the non - threaded portion of the valve stem. 6. Mount the OSYSU loosely with the trip rod centered in 2. Mount the OSYSU loosely with the carriage bolts and groove. clamp bar supplied. 7. Final adjustment is made by loosening 2 screws (see Fig. 2) and sliding the OSYSU on the bracket. Adjustment is 3. Loosen the locking screw that holds the trip rod in place correct when switches are not activated with the trip rod and adjust the rod length (see Fig. 4). When adjusted seated in the valve stem groove and that the switches properly, the rod should extend past the valve screw, but activate within one turn when the valve is operated from the not so far that it contacts the clamp bar. Tighten the FULL OPEN towards the CLOSED position. locking screw to hold the trip rod in place. 8. Tighten the adjustment screws and mounting hardware. NOTE: If trip rod length is excessive, loosen the locking Check to insure that the rod moves out of the groove screw and remove the trip rod from the trip lever. Using easily and that the switches activate within one turn when pliers, break off the one 1" (25mm) long notched section the valve is operated from the FULL OPEN towards the (see Fig. 5). Reinstall trip rod and repeat Step 3 proce- CLOSED position. dure. NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT 4. Mark the valve stem at the center of the trip rod. THE STEM THREADS DO NOT ACTIVATE THE SWITCH. 5. Remove the OSYSU. File a 1/8" (3,2mm) deep groove THE SWITCH BEING ACTIVATED BY THE STEM THREADS - centered on the mark of the valve stem utilizing a 3/8" COULD RESULT IN A FALSE VALVE OPEN INDICATION. PRINTED IN USA MKT. #8820004 - REV P PAGE 3 OF 4 12/01 r OSYSU -1, -2 !,, p i t POTTER OUTSIDE SCREW AND YOKE VALVE r,,.°4, The Symbol of Protection SUPERVISORY SWITCH FIG. 3 DIMENSIONS FIG. 4 PARTS l,g ( .i' l9r) -..1 car. (6.00 R.C. /,/ TM 100 ��. IIDOC 9f.RCR ��` 0a101f15 • • m 101 im FOR (l(COSUL - f]Acm) CON(CTO6 L _. 0 ii- REIP ROD I) o j O 0 / me (]g,) I ,sa I I I I ioo onoQ9 ),,J 9.m. N]9 -6 1=1 C.O. 1979-9 BREAKING EXCESSIVE ROD SWITCH TERMINAL TYPICAL ELECTRICAL CONNECTIONS LENGTH CONNECTIONS CLAMPING PLATE LOCAL CIRCUIT 1 N.O. INDICAT FIGS TERMINAL TO POWER FOR Q� DEVICE +NC COM. N.C. INDICATING DEVICE TO SUPERVISORY CIRCUIT 1 N.O. END OF 1 , 1- ` *. I. • OF CONTROL PANEL ° LINE C014. N.C. RESISTOR P' owc /ez� - DWG. #979 -1 C..�E 1.41. - CAUTION: An uninsulated section of a single conductor Contacts shown in normal (valve open) condition. should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervi- TYPICAL SWITCH ACTION sion of the connection in the event that the wire becomes dislodged from under the terminal. OPEN VALVE POSmON CLOSED VALVE POSITION COAT. N.O. COU_ N.O. ORDERING INFORMATION �+ #+ sW #' MODEL DESCRIPTION STOCK NO. I N C N.c. I ir- OSYSU -1 Outside Screw & Yoke - Supervisory Switch (Single switch) 1010106 I I OSYSU -2 Outside Screw & Yoke - Supervisory Switch (Double switch) 1010206 COAL. I NA. COM. I NA. — Cover Screw 5490344 sw #2 Sw #2 N C. N.C. -- Hex Key for Cover Screws and Installation Adjustments 5250062 -- Optional Cover Tamper Switch Kit 0090131 DWG. x/979 -2 For pressure reducer type valve installation kits (if required) contact valve manufacturer. PRINTED IN USA MKT. #8820004 - REV P PAGE 4 OF 4 12/01 f 1,. _ MODEL PSI OA fir ,,, A f : w S � * t ... - / � ` ''' t. "s, ® PRESSURE SWITCH A Potter Electric Signal Company Potter Electric Signal & Mfg. LTD . 2081 Craig Rd.,/P.O. Box 28480 1967 Leslie Street St. Louis, MO 63146 Don Mills, Ontario, Canada M3B2M3 (314) 878 -4321 / (800) 325 -3936 (416) 441 -1833 MODEL PS10A PRESSURE SWITCH IS FOR SUPERVISING DRY PIPE UL USTED & FM, LPC APPROVED SYSTEMS, WET ALARM CHECK VALVES Dimensions: 4 3/4"W x 2 1/4 "D x 4 3/8 °H L ,' t ,aY h F w a { X k if Y . J ; a * :;z k I '� .; - • w jk r �` £ t - ,T .o- ' * !• r '. Enclosure: Cover- Diecast aluminum with textured red powdercoatfinish - .� ° , f ti� x Base- Plated Steel „ .. cf r Y4 y ',rt, ti w , 5 i f 'S'£ 1, 't t ,� M1 N7'j °q a Z r ? T * .. ', by ``kp ` 7 1 . 4 0 t. 6 , ' € , Y ,: $; ' � } t Pressure Connection: 1/2" NPT Male �t 1 { *":iN i ''.:':':Ii.,,./:,,:4.1,.,,,". ' W y W Y Factory Adjustment Operates on Pressure Increase at 6 ±1 PSI Y •• 1 ; E j: tiAL - t 'v : Operates on Pressure Decrease at 5 }1 PSI '' -, ,, ,,-..,..,;7•:.•:', ; .:,„.•--,:-,Y- ` , '' 1 SgIG gIG K 0 1� '„ . -s r t , r, rq • Y Y £ SC r o ,; isk, € f` "' , h P ST � - - �tl � � Maximum Differential: 1 PSI rV� P kirZ Maximum System Pressure; 250 PSI ' ��F� � ��S`h, s �! � � , ���� 4 ., , � z r ' r "� r 3 4 � ,r." eo ' 1 :: : :' ' ''' ''', Switch Contacts: S.P. D.T. (Form C) :4“:" Y'>Y7 t t a rr ,I 'Si ` K `' ; ° x ''° $' " r * 10.0A •@ 125/250VAC, 2.5A @ 0 - 30V DC « One set inPS10- 1A,TwosetsinPS102A ,t 1 '! t ''Ar ; y : Y - X Re 's ' .✓ . ; j� t1 j 1 ra Y ,�_Zf p�S F,4!,1,::;;::::4;;::,. ` 3 1 , y tr'SL �c . x t * n r � � f r�. , ; t E,� n.'. 3, L, > Environmental Specifications: .. c v ? ' a " ` " . a r x - p Indoor or Outdoor Use , . N ,� . `, R • ✓ , Y ' r . ..,.,..A.,„•:,.1-,...i.,,,, , , . • NEMA 4 Rated Enclosure `0,' ; r ..0 r. f ': Temp.: 0 °F to 140 °F / -40 °C to 60 °C p.: Vi r 9 }; " ' ! f (Not for use in hazardous locations) tar.,....-40.1t4;;; } �,� Y ° c 7� r�, t F• r. .. . .,: Service Use: Automatic Sprinkler NFPA -13 a , F'��o Central Station NFPA -13D Local NFPA -13R Auxiliary NFPA -728 r: i Remote Station NFPA -71 Proprietary NFPA -72 PS Single Switch - No. 1340101 Tamper: Cover incorporates tamper resistant fastemers that require a PS10 -2A Double Switch - Stk. No. 1340102 special key for removal. One key is supplied with each device. For optional cover tamper switch kit, order Stk. #0090134. INSTALLATIONS & TEST PROCEDURES The Potter PS10A Series Pressure Actuated Switches are designed a control that does not provide a retard feature - the PS10A must be for the detection of a waterflow condition in automatic fire sprinkler installed on the alarm outlet side of the retard chamber of the sprinkler systems of particular designs such as wet systems with alarm check system. valves or dry pipe systems. They may also be used to provide a low TESTING: Accomplished by opening the inspectors end -of -line test pressure supervisory signal. They may be adjusted to operate on valve. Allow time to compensate for system or control retard. pressure between 4 and 20 PSI. Caution: Method 2 is not applicable for NFPA 71 service use. WET SYSTEM WITH EXCESS PRESSURE: MOUNTING: Device should be mounted in upright position (threaded Connect PS10A into alarm port piping extending from alarm check connection down). valve. Retard provisions are not required. Insure that no shut off Requires NEMA type 4 conduit hub for outdoor installations, valves are present between the alarm check valve and the PS10A. TESTING: The operation of the pressure alarm switch should be TESTING: Accomplished by opening the water by -pass test valve or the ins ectors end-of-line test valve. When using end-of-line test, tested upon completion of installation and periodically thereafter in p accordance with the applicable NFPA standards and /or the authority allow time for excess pressure to bleed off. having jurisdiction, but under no circumstances less than bi- monthly. DRY SYSTEM: Connect PS10A into alarm port piping that extends from the interme- WET SYSTEM: diate chamber of the alarm check valve. Install on the outlet side of the METHOD 1: When using PS10A and control unit with retard - connect PS10A into alarm port piping on the input side of retard chamber and in -line check valve of the alarm port piping. Insure that no shut off electrically connect PS10A to control unit that provides a retard to valves are present between the alarm check valve and the PS10A compensate for surges. Insure that no shut off valves are present TESTING: Accomplished by opening the water by -pass test valve. CAUTION: The above tests may also activate any other circuit closer between the alarm check valve and PS10A METHOD 2: When using the PS10A for local bell application or with or water motor gongs that are present on the system. ' MKT. #x810001 - REV 0 PAGE 1 OF 1 PRINTED IN USA MFG. #5400923 I r, MODEL. PS1OA h n s w ` ® PRESSURE SWITCH DIMENSIONS SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL la o COY. M.O. KG I I I 1 _ - 1 v7A ADJKUST4EN7 . ki . I I I ■ - O `ow O 2750 "11141‘...° ‘ O / � / N095 NOTE: - I � �� I 1 I \ \ TO PREVENT 1 = " I 1 i _ ' � I 4.375 �/ Jl LEAKAGE. APPLY ._ TEFLON - c i`N G TAPE SEALANT TO -- ry.S DwG. 1921 -3 MALE THREADS ONLY. CAUTION: AN UNINSULATED SECTION OF A SINGLE CON - � � DUCTOR SHOULD NOT BE LOOPED AROUND WARNING: USE OF PIPE JOINT .........-"."'"'"--"..."."--".". ...--.---- THE TERMINAL AND SERVE AS TWO SEPA- CEMENT MAY RESULT �— RATE CONNECTIONS. THE WIRE MUST BE IN OBSTRUCTION OF I 3.198 SEVERED TO SERVE AS TWO SEPARATE CON - THE APERTURE AND NECTIONS. THEREBY PROVIDING SUPERVI- 1 LOSS OF SIGNAL. .12 - SION OFTHE CONNECTION IN THE EVENT THAT THE WIRE BECOMES DISLODGED FROM THE DWG. 4923 2250 4.750 TERMINAL TYPICAL SPRINKLER APPLICATIONS WET SYSTEM— NOT APPLICABLE DRY SYSTEM WET SYSTEM WITH OR WITHOUT EXCESS PRESSURE FOR NFPA 71 SERVICE USE PS10A ALARM PRESSURE PS1OA STITCH PS10A WATER WATER • caHC �^` ROTOR . • • VCT1 WATER RETARD I oRY GEC% WET SISTER MID/ - � AlA1N RETARD VALVE •—> CHECK CHECX VALVE P. • ► • VALVE • • • VALVE • • • • WATER LOCAL .VMY MATER LOCYL MARY WATER LOCAL MARY 03 k • • VALVE S VALYE OS r Y • ST-PASS 9 OFF V� LVE. VALVE - VALFVE OFT .. VALVE • VALVE • DRG 1923-2 CAUTION: CLOSING OF ANY SHUTOFF VALVES BETWEEN THE ALARM CHECK VALVE AND PS10A WILL RENDER THE PS10A INOPERATIVE TYPICAL ELECTRICAL CONNECTIONS PRESSURE SWITCH LOCAL CIRCUIT STYLE D (CLASS A) SUPERVISED LOOP STYLE B (CLASS B) SUPERVISED CIRCUIT TERMINATION TRANSFORMER OR BATTERY POWER INCREASING � To — \ -� SYSTEM — s >.0 x �• LA41 < COY. po—OE_ RESISTOR PRESSURE N.C. P4.0. OEMCC 0. N.O. lAat °m 003-13 COM. N.O. ORDERING INFORMATION Mode( Description Stk. No • COM. N.C. N.O. PS10 -1A Pressure switch with one set S.P.D.T. contacts 1340101 N.C. COM. I PS10 -2A Pressure switch with two sets S.P.D.T. contacts 1340102 DECREASING N.O. Hex Key 5250062 SYSTEM Cover Tamper Switch Kit 0090134 PRESSURE O ENGINEER /ARCHITECT SPECIFICATIONS DWG. 1923 - 4 COM. N.C. N.O. Pressure type waterflow switches shall be a Model PS10A as manufactured by Potter Electric Signal Co. of St. Louis, Mo. and shall be installed on the sprinkler systems as shown on the drawings and /or specified herein. Switches shall be provided with a 1/2' NPT male pressure connection to be connected into the alarm check valve of a'wet' sprinkler system or into the intermediate chapter of 'dry' pipe system and shall be actuated by any flow of water to or in excess of the discharge from one sprinkler head. Switches shall have a maximum service pressure rating of 250 PSI and shall be factory adjusted to operate at a pressure of 4 to 8 PSI. There shall be one (1) or two (2) S.P.D.T. contacts rated at 10.0 Amp. @ 125/250VAC and 2.4 Amp. @ 0.30VDC. ' The switch housing shall be weather proof and oil resistant. The cover shall incorporate tamper resistant screws. The unit shall be listed by Underwriters Laboratories, Inc. and approved by Factory Mutual. PRINTED IN USA MKT. #8810001 - REV C PAGE 2 OF 2 MFG. #5400923 M® OA `; • . 4F HIGH /LOW r PRSSURE SWITCHES Potter Electric Signal Company Potter Electric Signal & Mfg. LTD 2081 Craig Rd., /P.O. Box 28480 1967 Leslie Street St. Louis, MO 63146 Don Mills, Ontario, Canada M3B2M3 (314)878 -4321 / (800) 325 -3936 (416) 441 -1833 MODEL PS40A PRESSURE SWITCH FOR MONITORING UL LISTED & FM, LPC APPROVED HIGH AND /OR LOW PRESSURE VARIATIONS Dimensions: 3 3/4 "W x 2 1/4 "D x 4 7 /8 "H Enclosure: , Cover - Cast Aluminum Finished in Red Enamel 4 r� `r ' . ,fix Base - Plated Steel ; ;, a a ' ,7 _ 'N Pressure Connection: 1/2" NPT Male Polysulfone 9 . x 1 3 t .47. ', .- , : 4 , r ' ` 1 , w ' f Factory Adjustment: PS40 -1A - Operates on decrease at 30 PSI -4.-t-0'.• `.. F ° r ,, . '4r ` , . PS40 -2A - Operates on increase at 50 PSI, a ��v�' 1 fi ' 1 f �`:w. �4 i Lk' HA 1W'-' ' K `E CTR = C PRO TECTI ON and on decrease at 30 PSI . 4 � . -, . - Pressure Range: 20 - 175 PSI 1 } t * : r = ` �, , , : .4.. ,n Differential: Approx. 2 lbs. @ 20 PSI , fi � ,.�� �� fi , , f , p � � ,' 5 lbs. @ 175 PSI ton; t 1 6 x i r i "i , , ' fr,r '1fi ' k .';',.",: f f J �' " ' r , ` :' 1 ' - � < . _', Maximum System Pressure: 250 PSI '; Switch Contacts 10.0A @ 125/250V AC 2.5A @ 6/12/24V DC .- t -t- „ te r ... --- . t i 4 `'' Environmental Limitations: Indoor or Outdoor Use -40°F to 140 °F (40 °C to 60°C) F 11'" , Service Use: Central Station NFPA -71 Local NFPA -72A Auxiliary NFPA -72B Remote Station NFPA -72C Proprietary NFPA -72D PS40A Series The Potter PS40A Series are pressure actuated switches is factory adjusted so that one set of contacts operate on a designed primarily to detect a 10 PSI increase and/or pressure increase at 50 PSI. The second set operate on a decrease from normal system pressure in automatic fire decrease at 30 PSI. These switches can be adjusted to sprinkler systems. operate between 20 and 175 PSI. Typical applications are air pressure supervision in dry pipe These units have an all metal weatherproof enclosure with systems and pressure supervision of pressure tanks, air a 1/2” NPT polysulfone pressure connection. The covers supply or water supply. are held in place with tamper resistant screws that require a special hex key for removal. One key is furnished with The PS40 -1A has one set of S.P.D.T. contacts and is each unit. - factory adjusted to operate on a pressure decrease at 30 PSI. The PS40 -2A has two sets of S.P.D.T. contacts and An optional cover tamper switch is available. Es. 8810002 PAGE 1 OF 2 PRINTED IN USA REV A . ;IA1V MODEL PS40A `' x HIGH /LOW • PRSSURE SWITCHES PS40A Series Dimensions i . o ,,, I co ". No. ..c. I I g I , � ' :LrS'4:`:T 2.750 ~ ANOaS I j • _J T " �a 73- 1 I I I r- r :1:1° I I 4.375 l � 1 I • 1 +-1.125 — I 3.188 2.250 I 4.750 DWG. #925 -30 Typical Sprinkler Application - Dry System PS 40A PSIOA AP WAT ER RESSURE LARM GONGR SWITCH GONG AIR LINE SHUT -OFF ' DRY SYSTEM CHECK VALVE T I E SYSTEM VALVE CHECK VALVE CHECK VALVE SVL VALVE _ • 1� WATER LOCAL ALARM 9Y - PASS SHUT OFF CWG. #924 -1 • . • OS. ALV . i TEST VALVE VALVE Ordering Information Model Description Stk. No. PS40 -1A Pressure switch with one set S.P.D.T. contacts 1340401 PS40 -2A Pressure switch with two sets S.P.D.T. contacts 1340402 BVL Bleeder Valve 1000018 Hex Key 5250062 Cover Tamper Switch 0090134 Engineer /Architect Specifications Air pressure supervisory switch shall be a Model PS40A as manufactured by Potter Electric Signal Co. of St. Louis, Mo. and shall be installed on the sprinkler systems as shown on the drawings and /or as specified herein. Switches shall be provided with a 1/2" NPT male pressure connection to be connected into the air supply line on the system side of any shut -off valve. A Model BVL bleeder valve as supplied by Potter Electric Signal Co. of St. Louis, Mo. or equivalent shall be connected between the air line to provide a means of testing the operation of the supervisory switch. The switch unit shall contain () S.P.D.T. (Form C) switches, one switch shall operate at a pressure increase of 10 PSI from normal. Switch contacts shall be rated at 10.0 Amp. @ 125/250V AC and 2.5 Amp. @ 6/12/24V DC. The units shall have a maximum pressure rating of 250 PSI and shall be adjusted from 20 to 175 PSI. The switch housing shall be weatherproof and oil resistant. The cover shall incorporate tamper resistant screws. The unit shall be listed by Underwriters Laboratories, Inc. and approved by Factory Mutual. 8810002 PAGE 2 OF 2 REV A PRINTED IN USA i , 34 M'Y rs LV 1 •. T} 7R 7 , ' x.'., 1 E f r 1 .� I 'R♦ P , y y � 1 4 *{ .t. y[ 4 C,. �rq + l t�> {F { ' , � r 7 + � . , � ry va t . r r C 4 ' a Is � w,� _ .� ., ...�� r , a t � �4„ r � �.1 �ra� a � �t � .� rktr � - � F, t b '� rP � � M ::. kkRAutov .-51 s4 3 D %5 w 3R is , , t; k-O3 - Au �� ��CENT � �11 �� � �... �4 .�,� � � rtsG,.�3 W � a s M ,. �-� �� ,�,�� � 4 �,ak �'"x �n',�M S -: ^u� yi'µ� .�p'.+,"4"�„ z ;3`K['�, t ,� 4...4 .3� a4- "�C;.'�..,r:��Y� ^ h,�. r_�,'`.':!X{ t�...r�4 r. a��-o, ?.�.`Ut r..'.'#. t ;.x ... ,. n. ., .. ., ,..,y �'? #,n.,: d.? r Pe ;..x ... ..as. ^L n3 ,a dn.wT p.. .. ,...„._ I Ma nifold _r Figure 513, 513D/513R Commercial CENTRAL - N FPA 13 Systems Grooved Piping Products Floor Control - High Rises Residential - NFPA 13D/13R Systems Tyco Fire Products — www.tyco- grooved.com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 — USA Customer Service /Sales: Tel: (215) 362 -0700 / Fax: (215) 362 -5385 Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 G eneral The threaded ends of the 1" and 11/2" Te ch n i ca l bodies, the threaded by grooved ends r r of the 2" bodies, and the grooved ends D escription of the l / " -6" bodies allow for an easy Data transition to either check or control :;. Y ,,.:'.' :::::$::::. valves. The exclusive and dedicated . f ' ., flow switch designed for the manifolds Figure: 513 (commercial) has been tested and Listed for use in 513D (residential) '" ``' this specific configuration b p g by 5130l51311 (residential) • :;, . . .. Underwriters Laboratories, Styles: Threaded or Grooved ` '•' Underwriters Laboratories of Canada '::::: ::::::a:'titi and Facto Mutual. Sizes: l ", 1'/2 ", 2 ", 2Y2 ", 3 ", 4" and 6" Approvals: UL, FM, and ULC . :V::::* ' ' ` ' 'ii' ''` Installation is simplified with one Maximum convenient take -out for the 1" and 11/2" Working Pressure: 175 psi < : we threaded and 1 grooved ve as Standard Finish: Painted "` well as one take -out for the 2" threaded : ^s: -'�' ::;;:;;� . Optional Accessories: by grooved and the grooved sizes Pressure Relief Valve Kit (see page 7) 2" - 6 ". 01 See Fire Protection I Submittal Sheet for The Riser Manifold is approved for ® pressure rating and Listing installation in either the horizontal or and Approval information the vertical position. The optional relief valve assembly is available for The Figure 513, 513D/513R Riser locations which require relief valves on Manifold provides all of the accessory gridded systems. equipment for a riser in a single assembly. The availability of the Riser Riser Manifolds for use in Canada only Manifold in different configurations are provided with a Water Flow Switch allows cost effective riser installation in that has a Tamper Switch mounted commercial (NFPA 13) systems, high inside for cover removal detection. rises requiring floor control assemblies, and residential systems (NFPA 13D/13R). • No. 28 -1.0 1 c Figure 6 s \ 2', 2' /i , 3', 4', and 6' % �� - �_ 5.5'3 [139.71 I Grooved Commercial Riser Manifold - Figure 513 For optional pressure relief valve, see Figure 10 (page 7) e I \ Approximate Weights and Dimensions of Trimmed / j ( " 2 ", 2'/2", 3 ", 4', and 6' Grooved Commercial Riser Manifolds s Size A B C D Appx. Width Weight n • `' Inches Inches Inches Inches Inches Inches Lbs. ■ mm mm mm mm mm Kg. ••,3.00 � 1 � [ , �:� ; -- 17.13 0.88 12.88 5.25 3.50 13.5 1330 .2] ! 1 Il / , 2 135.0 22.2 327.0 139.7 88.9 6.1 - ' i 18.13 1.88 13.75 6.38 3.50 16.8 j ''',, 0 `J A - -" 21/2 460.4 47.6 349.3 155.6 88.9 7.6 111111111•11 111111111•11 a 18.13 1.88 14.38 6.25 3.50 18.7 "p ' Y 3 460.4 47.6 365.1 158.8 88.9 8.5 - 4 20.00 3.75 17.38 8.38 4.50 32.7 B -► 508.0 95.3 441.3 212.7 114.3 14.8 ;11 1 1 6 20.00 3.75 19.25 9.25 6.63 41.6 t . L -.r = n6 508.0 95.3 489.0 235.0 182.3 18.9 I D ' Approximate thread engagement. '" 13' is the take -out for all sizes 2' through 6' Figure 5 and 6 - Bill of Material Note: Values shown in parenthesis are in millimeters 2" Grooved, 2' Threaded x Grooved and 2 ", 2 3', 4 °, and 6' Commercial Riser Manifold Detail No. Part No. Description Req'd Number 2° Manifold Body Groove x Groove 1 976 - 254 -01 21/2' Manifold Body Groove x Groove 1 976 - 254 -02 1 3" Manifold Body Groove x Groove 1 976 - 254 -03 4" Manifold Body Groove x Groove 1 976 - 254 -04 6" Manifold Body Groove x Groove 1 976 - 254 -05 • •:1a 2° Manifold Body Male x Groove • 1 . 976 - 411 -01 Potter Waterflow Switch # VSC w/ 2' Paddle 1 . 976 - 357 -01 • . • Potter Waterflow Switch # VSC w/ 2W Paddle 1 976 - 357 -02 2 Potter Waterflow Switch # VSC w/ 3' Paddle 1 976 - 357 -03 Potter Waterflow Switch # VSC w/ 4' Paddle 1 976-357 -04 Potter Waterflow Switch # VSC w/ 6' Paddle 1 976 - 357 -05 1' Ball Valve F101 (2 ") 1 971 - 121 -01 3 f' /4" Ball Valve F101 (21/2' and 3 ") 1 971 - 121 -02 2" Ball Valve F101 (4' and 6') 1 971 - 121 -03 1" Insp. Test & Drain Valve F202 (2') w /'/2' Test Orifice 1 971 - 122 -04 4 11/4" Insp. Test & Drain Valve F202 (2 and 3') w/ 1/2' Test Orifice 1 971 - 122 -05 2' Insp. Test & Drain Valve F202 (4' and 6') w/ Y' Test Orifice 1 971 - 122 -06 1" Sight Glass (2 ") 1 H- 418 -100 5 11/4" Sight Glass (2h/2' and 3 1 H- 418 -125 2" Sight Glass (4" and 6') 1 H- 418-200 6 /4° Water Pressure Gauge 1 971 - 118-01 7 1/4" Pipe Plug 1 H- 450 - 025 -000 8 1/4° 3-Way Globe Valve 1 971 - 119 -01 9 1/4" x 3' Nipple 1 H- 459-025 -30 10 1" Pipe Plug 1 H- 450-100 -000 1" x Y' x 1' Reducing Tee (2 ") 1 H- 469 - 100-050 -100 11 114" x A' x 11/4' Reducing Tee (2' and 3') 1 H- 469 - 125 - 050 -125 2" x' /i x 2' Reducing Tee (4' and 6') 1 H- 469-200-050 -200 12 ' '/z° Pipe Plug 1 H- 450 - 050 -000 13 1" x' /2" x 1' California Tee 1 976-385 -01 14 1' Close Nipple 1 H-474 -16 15 1' Ball Valve F101 1 971- 116 -03 16 Tamper Switch (ULC only) 1 H- 419 -01 17 Label (ULC only) _ 1 _ 976 - 343 -01 Note: Items 16 & 17 are used on Manifolds for use in Canada Only. 5 Figure 7 Potter Watertlow Switch Terminal Connections .1 � c ° Caution: An uninsulated section of a single conductor is not permitted to be looped around the terminal and serve as two separate connections. The wire must be severed to serve as two separate connections, thereby providing supervision of the connection in the event that the wire becomes dislodged from the terminal. Figure 8 Potter Watertlow Switch Typical Electrical Connections Style B / Class B Local Bell Transformer or End of Line Resistor Battery Powered CKT.(see note) Open on Alarm / Close on \\ / Alarm Open on )1 Close on End of Line Alarm Alarm Resistor Signaling Device ' N Supervised Loop Typical Switch Action (see note) �o \ / To Additional Open on ' Close on From Open on Close on Devices or Alarm er o Alarm Control Alarm i • Alarm Return to - • Panel / \ • Control Note: For supervised circuits, see °Switch Terminal Connections° and caution note (above). The Model VSC and Model VSR -SF have two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operatea local audible or visual annunciator. Testing: The frequency of testing for the Model VSC and Model VSR -SF and their associated protective monitoring system should be in accordance with applicable NFPA Standards and /or the Authority Having Jurisdiction, but under no circumstances less than bimonthly. Figure 9 Potter Tamper Switch Typical Electrical Connection • Contacts S.P.D.T. (form C) N.C. A Com. Contacts shown with - 0 Cover in Place Contact Rating: 5A@125V AC N.O. 2.5A@30V DC Installation for Models VSC and VSR -SF: Remove the one retard assembly mounting screw. Place the switch assembly over the retard mounting tab. Replace the screw. 6 Figure 10 Optional Pressure Relief Valve Grooved Commercial Trim - Figure 513 Q O Q lk -,%-- ( )) \ \ __ ^_ ____. Relief Valve is factory set at 175psi (nonadjustable). It 'i 0 Note: If the optional pressure relief kit is desired for Figures 3 and 0 I i i i_ 4, an outlet on the riser must be provided, and the connection and / _' -- material between the riser and the manifold will need to be supplied \ F 8 and fabricated by the installer. 7 NiRMA! I.: A .0 NORNAILY W 7RAW mom 9j Of F'CSI::ON n J' Figure 10 - Bill of Material Optional Pressure Relief Valve Kit Detail No. Part No. Req'd Number 1 90° Compression Fitting 2 H- 475 -050 -038 2 ' /z" Watts Pressure Relief Valve Model FP53L (UL, FM) 1 H- 476 -01 Tubing (2 ") 1 976 - 419 -01 3 Tubing (2 and 3') 1 976 - 419 -02 Tubing (4° and 6') 1 .976- 419 -03 4 1" x' /z" Reducing Bushing.. 1 H- 477 -01 M = Male N.P.T. F = Female N.P.T. Optional Figure 513 Pressure Relief Valve Kit G = Grooved Connection Size Part Number 2" 4063 2W and 3" 4072 4' and 6' 4073 - Part Size Figure Number Size Figure Number 1" 513D, F x F (UL, FM) 4067 2" 513D/513R, M x G (ULC) 4094 1" 513D, F x F (ULC) 4085 2' 513D/513R, G x G (UL, FM) 4059 11/2' 5130/513R, F x M (UL, FM) 4057 2' 513D/513R, G x 0 (ULC) 4093 11/2' 513D/513R, M x M (UL, FM) 4058 2' 513, G x G, 1/2' Test Orifice (UL, FM) 4060 11/2" 5130/513R, F x M (ULC) 4088 2' 513, 0 x G, Test Orifice (ULC) 4090 11/2" 513D/513R, M x M (ULC) 4089 21/2' 513, G x G, 1/2" Test Orifice (UL, FM) 4061 11/2" 513, F x M'' /2" Test Orifice (UL, FM) 4055 21/2' 513, G x G,' /2" Test Orifice (ULC) 4091 11/2" 513, M x M' /2" Test Orifice (UL, FM) 4056 3' 513, G x G, Y Test Orifice (UL, FM) 4062 11/2" 513, F x M' /2' Test Orifice (ULC) 4086 3' 513, G x G, 1/2' Test Orifice (ULC) 4092 -, 11/2" 513, M x M'' /2' Test Orifice (ULC) 4087 4' 513, G x G,' /2 Test Orifice (UL, FM) 4065 11/2' 513, G x G'' /x' Test Orifice (UL, FM) 4056G 4' 513, G x G,' /2' Test Orifice (ULC) 4095 11/2" 513, G x G' /z" Test Orifice (ULC) 4087G 6° 513, G x G, 1/2" Test Orifice (UL, FM) 4066 2" 513D/513R, M x G (UL, FM) 4064 6' 513, G x G,'/2" Test Orifice (ULC) 4096 7 • ` s• o fi Limited m ite d Products neither assumes, nor 6 authorizes any person to assume for it, ,x. Ordering ' any other obligation in connection with � I Warranty the sale of products or parts of P ®ce K ` :.. s .; products. Tyco Fire Products shall not <11111111'` be responsible for sprinkler s stem Products manufactured by Tyco Fire P P Y Ordering Information: When placing an Products are warranted solely to the design errors or inaccurate or order, indicate the full product name. Please original Buyer for ten (10) years against incomplete information supplied by specify the quantity, figure number, style, defects in material and workmanship Buyer or Buyer's representatives. and size. (see page 7 for figure and part when paid for and properly installed IN NO EVENT SHALL TYCO FIRE numbers) and maintained under normal use and PRODUCTS BE LIABLE, IN Availability and Service: Grooved Piping service. This warranty will expire ten CONTRACT, TORT, STRICT Products, valves, accessories and other (10) years from date of shipment by LIABILITY OR UNDER ANY OTHER products are available throughout the U.S., Tyco Fire Products. No warranty is LEGAL THEORY, FOR INCIDENTAL, Canada, and internationally, through a given for products or components INDIRECT, SPECIAL OR network distribution centers. You may write manufactured by companies not CONSEQUENTIAL DAMAGES, directly or call 215-362-0700 for the affiliated by ownership with Tyco Fire INCLUDING BUT NOT LIMITED TO • distributor nearest you. Products or for products and LABOR CHARGES, REGARDLESS OF . components which have been subject WHETHER TYCO FIRE PRODUCTS to misuse, improper installation, WAS INFORMED ABOUT THE Care and corrosion, or which have not been POSSIBILITY OF SUCH DAMAGES, installed, maintained, modified or AND IN NO EVENT SHALL TYCO repaired in accordance with applicable FIRE PRODUCTS' LIABILITY EXCEED M aintenance Standards of the National Fire AN AMOUNT EQUAL TO THE SALES Protection Association (NFPA), and /or PRICE. The owner is responsible for the the standards of any other Authorities NG THE FOREGOING WARRANTY IS MADE inspection, testing, and maintenance of Having Jurisdiction. Materials found by IN LIEU OF ANY EGOING NDALL OTHER their fire protection system and devices Tyco Fire Products to be defective shall EXPRESS ES OR IMPLIED, in accordance with the applicable be either repaired or replaced, at Tyco WARRANTIES I S WARRANTIES EX PRESS OF standards of the National Fire Fire Products' sole option. Tyco Fire MERCHANTABILITY CLUDIN FITNESS in Association (e.g., 25), FORA PARTICULAR PURPOSE. in addition to the standards ds of f any any authority having jurisdiction. The installing contractor or product manufacturer should be contacted . relative to any questions. Any • impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. General Notes: It is the Designer's responsibility to select products suitable for the intended service 4111, and to ensure that pressure ratings and performance data is not exceeded. Always read and , understand the installation instructions (IH- 1000). Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and 9001 "• - gasket selection should be verified to be compatible for the specific application. ��1111/y Certified Company tEJCID FlcwControl Tyco Fire Printed in U.S.A. 1 -03 / Products 8 SELLS F PBA -AC & PBD -DC Potter Electric Signal Company Potter Electric Signal & Mtg. LTD 2081 Craig Rd.,/P.O. Box 28480 1967 Leslie Street . Don Mills, Ontario; Canada M3B2M3 • '' St�Lotils; MO' 63146 .. . (416) 441 -1833 (314)878 -4321 / (800) 325 -3936 UL LISTED, FM APPROVED Sizes Available: 6 ", 8 ", and 10" - '° Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized ®rorrtR y '.. Service Use Fire Alarm General Signaling Burglar Alarm • D Environment: Indoor or Outdoor Use (See notes) -40° to 150 °F (outdoor use require weatherproof backbox) Termination: 4 No. 18 AWG stranded wires ` Finish: Red powder coating 4? a Optional: Model BBK -1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar, or general signaling devices. - They have low power consumption and high decibel ratings. The unit mounts on a standard 4" square electrical box for indoor use, or on a model BBK -1 weatherproof backbox for outdoor applications. ALL DC BELLS ARE POLARIZED AND HAVE BUILT -IN TRANSIENT PROTECTION: Size Voi:age Model No. Stk. No. Current (Max.) Typical dB Minimum dB @ 10 FT. @ 10 FT. /->-- 6 12VDC PBD126 1706012 .12A 85 75 8 12VDC PBD128 1708012 .12A 90 75 10 12VDC PBD1210 1710012 .12A 92 75 6 24VDC PBD246 1706024 .06A 87 75 8 24VDC PBD248 1708024 .06A 91 79 10 24VDC PBD2410 1710024 .06A 94 79 6 24VAC PBA246 1806024 .17A 91 75 8 24VAC PBA248 1808024 .17A 94 75 10 24VAC PBA2410 1810024 .17A 94 75 6 120VAC PBAl206 1806120 .05A 92 82 8 120VAC PBAl208 1808120 .05A 99 10 120VAC PBAl2010 1810120 .05A 99 85 Weatherproof backbox model BBK -1 Stk. No. 1500001. • Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150 °F. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. PRINTED IN US C502 776 -E PAGE 1 CF 2 SELLS ..... . . .. .... • _ .. ,. PB A -AC & BD -DC DIMENSIONS FIG..1 FIG.. 2 BELLS . WEATHERPROOF BACKBOX Ill BOX HAS ONE THREADED 112' CONDUIT ENTRANCE M I il l 1a' 1 I ! 7 I 5 3 O 3 3/6 S. 6 s /6 '1 f E.3 '/tr j 1-..-2 11/16 DWG. #5400776-30 , DWG. #5400776 -30 FIG. 3 WIRING (REAR VIEW) OBSERVE POLARITY ON D.C. BELLS RED (IN) Adll RED (OUT) • Ai: , TO NEXT BELL OR FROM CONTROL PANEL 1101.410 OR END -OF -LINE OR PRECEDING BELL p RESISTOR BLACK (IN) ° BLACK (OUT) _1- DWG. #5400776 - 3 0 Li41.a Caution: Observe polarity to ring D.C. Bells. When electrical supervision is required Red wires positive ( +) use in and out leads as shown. Black wires negative ( -) INSTALLATION 1. The bell should be mounted a minum of 8 ft. from the floor or as close to the ceiling as possible. 2. Remove the gong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox. 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction. 776 PAGE 2 OF 2 C502 PRINTED IN USA I . Grinnell pipe rings 1 adjustable swivel ring • fig. 70 SIZE RANGE: Fig. 69 ' /z" - 8" tapped per NFPA standards Fig. 70 2'!? - 8" fig. 69 MATERIAL: Carbon steel. . FINISH: Plated. SERVICE: Recommended for suspension of non - insulated, stationary pipe line. — la r MAXIMUM TEMPERATURE: 650 °F. 4 '' I A PPROV A LS: Fig. 69 U nderwriters' Laboratories listed --.-0 . .4R and F ac tory Mutual approved' /." thru 8 ". Complies with F F ederal S pecificatio n WW-H-1 71 E (Type 10) and Manu- 1 um \ facturers Standardization Society SP -69 (Type 10). a FEATURES: = c • Threads are countersunk so that they cannot become \ ; ' burred or damaged. • Knurled swivel nut provides vertical adjustment after piping is in place. ��` I �� • Captured socket will not fall out. �.,- ORDERING: Specify size, figure number, name. • • . • . . • . . • loads • weights • dimensions (inches) max weight recom (approx) . pipe load, lb lbs each A B C F size Fig. 69 Fig. 70 Fig. 69, Fig. 70 Fig. 69 Fig. 70 Fig. 69 Fig. 70 Fig. 69 Fig. 70 Fig. 69 Fig. 70 '/2 300 .09 % 21/4 1 7 /6 ?i 300 .09 % 2 1','16 7 /6 1 300 .10 ; 2 1 " 300 25/6 1 it 7'6 1',: .10 ke l',', 300 .10 3 2 1 7 '6 '/: 2 300 _ .11 Ye 3 216 — l a— - ?— - 2 525 1000 .25 .33 % 'h 4 3'S' +6 2 2' , 6 1 In 1'b 6 3 525 1000 .27 .36 ?6 S 4 4 3 "e 3'.., I 1''6 1''iF 4 650 1100 .48 .56 y �6 4 .6 5 3" 3 1 1 i 1 _ 5 1000 1100 .53 . ' /t % 5 5'.'1 4% 4'/2 1 ih I 1 6 1000 1250 1.0 1.2 1/2, 'y 6 6 6'e 5'? 5'. 2' ∎., 2 8 1000 1250 1.0 1.4 !h '.i 8 8 7 7 2" Ih 2 "'∎ ph -10 Grinnell hanger rods machine threaded rods continuous thread: 146 ( - threaded both ends right -hand threads: fig. 140 � e right- and left -hand threads: fig. 253 1 ' A SIZE RANGE: 1 /4 through 11/2 inch diameter. Stocked in six, ten and twelve foot lengths. Other even foot lengths can be furnished to order. L . ---9 MATERIAL: Carbon steel; rod threaded complete 1•—D —I to I—D-1 length. • FINISH: Black or electro- galvanized. MAXIMUM TEMPERATURE: 750 °F. ORDERING: Specify rod diameter and length, figure number, name. loads • weights max recom MATERIAL: Carbon steel. rod load, lb weight size (approx) MAXIMUM TEMPERATURE: 750 °F. A 650 °F lbs ft ORDERING: Specify rod size, figure number, name, rod 1/4 240 .12 length. Specify thread length if other than standard. 36 610 .30 '/2 11130 .53 FINISH: Black or electro - galvanized. • • . 1 810 .84 r 3 /4 2710 1.2 r/6 3770 1.7 1 4960 2.3 loads • standard thread lengths 1'/4 8000 3.6 11/2 11630 5.1 . maximum ■ ' recommended rod load, lb standard rod size thread length .. A 650 °F 750 °F Dom, in coach screw rods 3/ 610 540 21/2 machine threaded on opposite end: 1/2 1130 1010 21/2 fig. 142 5. 13 1810 1610 2 3/4 2710 2420 3 ' 1 /6 3770 3360 3'/2 __. L- A -- D 1 4960 4420 4 1 8000 7140 5 1 '/2 11630 10370 I 6 MATERIAL: Carbon steel. 13/4 15700 14000 7 ORDERING: Specify rod size, figure number, name, rod 2 20700 18460 8 length. 21/4 27200 24260 9 21/2 33500 29880 10 standard thread lengths • loads 23/4 41580 37066 1 I coach 3 50580 1 45085 12 screw std max 3 60480 53906 13 rod standard thread rod the recom size rod lengths L. in D, in load, lb 31/2• 71280 63493 14 _ - 33/4• 82890 1 73855 1 15 3e 31/2 2 3/4 390 36 8 2 21/2 390 • %,'/2 and 9 /8 inch fig. 140 rod in lengths of 24 inch or shorter will be '/2 3' /z 2 3 /4 640 furnished as continuous thread rod unless order states that all thread 2 8 2 2'/2 640 i;) rod is not acceptable. % 4 2 3 : 760 • Furnished with 8 UN threads. 3 ;a 5 2 3 830 r I ph -59 r 1111 i • I ` Grinnell _clamp V . universal C-clamp beam clamps fig.92(standard throat) , retaining clip z ' g ■N io. fig: 89X .7;2 it i , • „ „ . , Ar . ,,,. _ ''''ll .1 For use with fig no.'s 92 & 93 in seismic applications. ........„,„,,., ik ' , , . tti I ; D,jj:! �..t LENGTH ; � ::: row' , .25 • I ' Z`4 . ' a ��� u.m, as k 1 7 ,> , 1 MEMP t : SIZE RANGE: 3 /8 &' /z inch rod. MATERIAL: Malleable iron clamp, hardened steel cup • : point set screw and locknut. -D - ;` APPROVALS: Underwriters Laboratories /Underwriters (SEE TABLE ) r ''' ' I I Labor atories of Canada listed and Factory Mutual r -. , - W 1 DTH - pipe sizes. - ,2 .1 '-!... I ' i approved for NFPA 13 maximum rated pip (SEE TABLE ) Complies with Federal Specification WW -H -171 E and "'• I ' I Manufacturers Standardization Society SP -69 (Type 19 i f I & 23). .: � i l : SERVICE Rmmed for use roof installations with bar joist type construction , or for und attachment to the 'I top or bottom flange of structural shapes. where the- ono --� -- C R. ; vertical hanger eco rod is required to e be offset o from ins the edge , 0 7 0 ?.'=;, ' to II of the flange and where the thickness of joist or flange , 1 a 4 y- ;.. 4 ' , does: not exceed 3 /4 inch. MATERIAL:. Low_ carbon steel to. ASTM --A569 -72 'Z, .. . .11‘"' , `-'` , i HOW TO SIZES Size of clamp is determined by size of (minimum tensile strength 30,000 PSI) :-., : r , rod to be used.. FINISH: Black or. plated. ^. -, ! ; 1 `: , IN Follow maximum recommended. set HOW TO SIZE: Specify length of retaining strap based -,_.- I ! screw torque values per MSS- SP -69. on beam size. R FEATURES: INSTALLATION: Length of strap should be adequate to -. a + y a4 ( , , . • They may be attached to horizontal flanges of structural • ache allow at lease one inch of strap to be bent over the beam ° - - members in either the top. beam or bottom beam side of the flange opposite the side the beam clamp is I positions. mounted on. 'Y • Secured in place by a cup - pointed Set Screw tightened -,.., against the flange. A Jam Nut is provided for tighten- ::::,,. - ;.j , i the Set Screw against the Body Casting. l';`,';''.: • Thru tapping of the bod casting permits extended dash diameter length ry body 9 P no. -0- tot. ± .060 width_ "- . ': adjustment of the threaded rod. -1 .41 I 6.00 I 1.00 • ORDERING: Specify rod size, figure number, name of -2 41 I 8.00 I 1.00 7 clamp. -3 .41 1.00 I - ' «' 10.00 4 41 14.00 1.00 ., . : loads •-• weights 5 .53 6.00 1.00 "' ." - . i maximum _ -6 .53 8.00 1.00 recommended 1 rod; max weight load, ibs.�. (approx.) -7 .53 10.00 - 1.00 - _ size Pity A size to j bottom lbs. each _8 .53 14.00 1.00 ifs 4 I 500 I 250 I .34 g .66 6.00 I 1.25 ,/: 8 950 760 -10 .66 800 1.25 I III- ': `` : Maximum temperature of 4 50 °F _ -11 .66 10.00 I 1 -25 4 dimensions (inches) -12 .66 14.00 125 , z. ',% 13 .81 I 6.00 1.25 I 14 I 81 8.00 1.25 • ``''' size 1.25 14 .. 1 A e I C I e E w /,a ?S 'h -15 I 81 I 10.00 = r - 3 /. I 1% 1' 'Ohs 1 he I ha I 14.00 1.25 ., +/ % he Y2 Vile I the I ' -16 .81 v-'.'- � . u Il ph �. tS �iL - ■ PIPE HANGER SUPPORTS . . . .. . . . .. ... . • . . . . ,.. .. . . . _.. . • ....„) .• . ... . : • ....sr... .. , . • ....• t : • ..........„, . .., \ i •• '. . . - ::•.!! ":?. IP 1 . . - - • ' • .. - .: ;/,' 7 ------ .1 -'' , . Atki:Itifar /fr _______ ii..11 . / ' // • • _ _ — --_ _____ ,, ./ ., i // / / •,- ,• ' . .• • /./ : '. • , . ',/ ... _ •/' • r 7 ,.' ,. , 7. , • ' • , • • • . , •. • %. _ .0 . . _ / . , , , I ;Z.- •• .2 I . ;AL r* orplaparipailla-- sp) 1 h. a , 1 amirstism am g A v aligentsszogra ! - A i - --- I. ----. • .. - • I -....,_/ TOLCO 132 coao►�c �c�i� 4599 I 6.909 NO-THREAD SWIVEL SWAY BRACE ATTACHMENT' Size Range — 1 and 1 -1/4 inch bracing pipe. For brace 0 pipe sizes larger than 1 -1/4 inch use Tolco Fig. 980. :.�,; State of Material — Carbon Steel, hardened cone point California engaging screw. yY OSHPD Function - The structural component of a sway and APPROVED seismic bracing system. '` Features — - � • No threading of the bracing pipe is required. _ '1' ` • Open design allows for easy inspection of pipe engagement. \` H • All steel construction eliminates deficiencies associates ' _' ' with malleable type attachments. • Fastener can be mounted to all surface angles. � 4 Application Note - The Fig. 909 is used in ti ..�� conjunction with the Tolco Fig. 1000 "Fast C1amprm ", A :,A y Fig. 2001, or Fig. 4(A) pipe clamp, and joined � together with bracing pipe. Install per NFPA #13 and /or Tolco's State of California OSHPD Approved n Seismic Restraint Manual. 7 Installation — Extend bracing pipe through opening. Tighten cone point engaging screw until head bottoms out. Approvals — Underwriters Laboratories Listed per 203A (UL). Approved by State of California Office j . of Statewide Health, Planning and Development ,/4 ( OSHPD). '' , _ :,,�;/ Finish — Plain, Electro Galvanized and"HDG. Order By — Figure number, pipe size and finish. ____ Important Note — The Fig. 909 is precision ' manufactured to perform its function as a critical component of a complete bracing assembly. O ,- To ensure performance, the U.L. Listing requires that the Fig. 909 must be used only with other Tolco bracing products. # NATIONAL AND INTERNATIONAL PATENT APPLICATIONS IN PROCESS. Standard washer (Fig. 115) ■. / required for 2765 lb. MAX design Ioad MAX. HORIZONTAL +//. HORIZONTAL DESIGN DESIGN LOAD LBS. APPROX. PIPE LOAD LBS. SIZE A B H° W/WASHER, /100 1 .6 1 -5/8 17/32 2015 2765 91 1 -1/4 6 1 -5/8 17/32 2015 2765 97 * Available with hole sizes to accommodate up to 3/4" fastener. Consult Factory TocO CORONA. CA • (909)73745' 99 FIG.825 BAR JOIST SWAY BRACE ATTACHMENT Size Range — One size accommodates all Tolco Fig. 900 Series sway brace State of Calilfornia attachments. Braces up to 8" pipe. _ OSHPD Material — Carbon Steel. APPROVED Function — *To attach sway bracing to steel bar joist structural members. 3 S" M ox. Features: •Permits secure non friction connection without drilling or welding. ■Unique design reinforces point of connection to joist > •Break off head bolt design assures verification of proper installation. :_• *Can be used as a hanger for up to 6 inch pipe. A Approvals - Underwriters Laboratories listed per 203A (UL).. Approved by � , : i ` State of. California Office of Statewide Health, Planning and Development :� ,.,,-..-I,..-‘); (OSHPD). Refer to Tolco's State: of California Approved Seismic Restraint ' i j Products -Manual. (J " ,' ! f Important Structural Note — The Tolco Fig. 825 has UL established :� / design loads as indicated. It should be verified that the structural members [ (i G%- to which this product is attached can withstand the expected forces. , ; :- Finish — Plain, Electro- Galvanized, and HDG. _ Order By — Figure number, and finish. D Max. x. Design Load 2,015 Lbs. *Important Note. — The. Fig. 825 is precision manufactured to perform its Weight/10 e 237.5 Lbs function as a critical component of a complete bracing assembly. To ensure performance the U.L. Listing requires that the Fig. 825 must be used only with other Tolco bracing products. _ Tout shown attached National and International P aunt application in process. • to various roof materials Optional , Naar Shown - i , Shown with -. i i /, Fig. 825 e �' ft-- 1 tii F 1000 l• I (di \ \, FRONT VIEW 1 1 Shown with r •••�• - 1 I Fi . 980 `/ Fig. 825 S ?; O °- • May pivot in ^It tail• �n - ` any direction . ? ) F 1000 !� Ftg. _ s 1;,-14 IL � k lI ) 1/2" Bolt &Nut V Rtraished SIDE VIEW : TOP VIEW ToicB INCORPORATED CORONA CA •(909)7 7 -5599 135 FIG.980 UNIVERSAL SWIVEL SWAY BRACE ATTACHMENT Size Range — One size fits bracing pipe 1 thru 2 inch, Tolstrut 12 g qa channel, and all structural steel up to 1/4 inch thick. e of Material — Carbon Steel. State California Function — Multi- functional attachment to structure or braced pipe fitting. OSHPD Features — *Fits multiple sizes of bracing pipe, strut or structural steel. o APPROVED .Mounts to any surface angle. ro": •Break off bolt head assures verification of proper installation. ,. ; Application Note - Install per NFPA #13 and /or Tolco's State of �� , _ t� .'. � *° California OSHPD Approved Seismic Restraint Manual.` - FnstaIla into jaw fully and tighten �, . bolt until head breaks off. ' 4 Approvals — Underwriters Laboratories Listed per 603A (UL). t - •- - �:: ° , Approved by State of California Office of Statewide Health, Planning A r-�'+ i \ and Development (OSHPD). Refer to Tolco's State of California : r Approved Seismic Restraint Products Manual. \ f B Finish — Plain, Electro - galvanized. Order By _ Figure number & Finish. Important Note — The;Fig. 980 is precision: manufactured to perform avat its function as a critical: component of a complete bracing assembly. To ensure perforrnance. the U.L. Listing requires that the Fig. 980 must be used only with other Tolco = s bracing roducts. �� '1. ::., NATIONAL AND INTERNATIONAL PATENT ' viii � i , , ` ~" } ■1 APPLICATIONS IN PROCESS. ' ;. r•. r,----- Max. Horizontal APPROX. A B 11* Design Load WTJ100 LBS. 5 -1/4 1 -7/8 17/32 2765 132 *Available with hole sizes to accommodate up to 3/4 inch fastener. Consult factory. ; i Shown with Tolco I �%` ,. Sh own with Tolco � � , / .. 7 Fig. 1000 "Fast Clamp" ..; . � Fig. 4A Pipe Clamp / , j ; /' ' \ N / N / � �/ / f( I i , 0i TDI -CO Revision 8/30/2002 a brand of l)N�811✓Q i Fig. 1001 @�� Sway Brace Attachment Size Range – Pipe size to be braced: 4 thru 8 inch IPS.' Pipe size used for bracing: 1 and 1 -1/4 inch Schedule 40 IPS. t Material – Carbon Steel. Function – For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace r / system: The Fig. 1001 is used in conjunction with a TOLCO '� 900 series fitting and joined together with bracing pipe per It I NFPA 13, forming a complete sway brace assembly. Features – *Can be used to brace schedules 7 through 40 ; IPS. Field adjustable, making critical pre - engineering of bracing pipe length unnecessary. Unique design requires no '. \� threading of bracing pipe. Can be used as a component of a t four -way riser brace. Comes assembled and ready for installation. Fig. 1001 has built in visual verification of correction installation. See installation note below. Maximum Design Load Lbs. installation Note – Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until Sch. 10/40 Sprinkler Pipe' Sch. Sprinkler Pipe heads bottom out. A minimum of 1 inch pipe extension is 2015 lbs. 1265 lbs. recommended. '2765 for 8' pipe with 1 brace pipe Approvals – Underwriters' Laboratories Listed in USA (UL) _ and Canada (cUL). Finish – Plain. Note— Available in Electro- Galvanized and HDG finish. Order By– Indicate pipe size to be braced followed by pipe size used for bracing, figure number and finish. Important Note - The Fig. 1001 is precision manufactured to �; perform its function as a critical component of a complete bracing assembly. To ensure performance. the UL Listing requires that the Fig. 1001 must be used only with other l TOLCO bracing products. S i • ' / i • t • i !f I , I I� Y c. , 170 Mai n Distriibut on Center � 8790 i Fruitridge Road • Sacramento, r CA 95826 • 9, 6:88 7800•F ax: 9 6:88.17401 0330 Manufacturing Facility • 4851 Homestead Road, Bldg. 118 • Houston, TX 77028 • Ph: 713.672.0058 • Fax: 713.672.0074 www.tolco.com ,.. a) T OLCO INCORPORATED CORONA, CA (909)737 -5599 0 C C) Fig. 4 A State California OSHPD D Approved Pipe Clamp For Sway Bracing . B Size Range - 4 thru 8 inch pipe. For pipe sizes smaller than 4 inch y use Tolco Fig. 4. Material - Carbon Steel. l � ` Function - For bracing pipe against sway and seismic / / �l 11.- disturbance. ' Approvals - Underwriters' Laboratories Listed in the USA (UL) / i A and Canada (cUL) 4 thru 8 inch. Approved by State of California Office of Statewide Health, Planning and Development (OSHPD). i Installation Instructions - Install Fig. 4 A Pipe Clamp on pipe to `� be braced. Attach Sway -Brace Fitting to 1/2" Clamp bolt (Sway- '� D Brace Fitting to be on outside ears of clamp). Tighten securely. (min. torque requirement -50 ft. lbs.) Sway Brace Assemblies are ` intended to be installed in accordance with NFPA 1t13 and the Manufacturers Installation Instructions. !�% Finish - Plain. Note — Available in Electro- Galvanized and HDG finish or Stainless Steel materials. Order By- Figure number, pipe size and finish. i i .o Fri- H Shown with two ' � . Shown with two . •� % • Tolco Fig. 980's and Tolco Fig. 980's and ; t• Schedule 40 Brace Pipe % • Toistrut Channel brace. n H �/ . s H . • Fig. 4A - Longitudinal Brace Fig. 4A - Transverse Brace PIPE MAX. HORIZONTAL APPROX. A B C D BOLT SIZE SIZES DESIGN LOAD. WTJ100 4 8 -1/2 9/16 3 -3/8 3 -11/16 1/2 2015 221 5 9 -3/4 9/16 3 -7/8 4 -3/8 1/2 2015 253 6 11 -1/2 5/8 5 5 -1/8 1/2 2015 513 8 13 -1/4 3/4 6 -11/16 6 -1/8 1/2 2015 601 ' . ; i,:Vi'i _." r L :s. ' ` r' s ., " 4,''', , r ,, , '4 ! A: r ti = . - ' t �� -y o>r: Sys$ K Bolt II Sttad An ' Single piece wedge that can function as three independent wedges. Stud expansion anchor to satisfy a wide range of concrete fastening 0 problems. il Anchor Program Product Details Advantages Kwik Bolt II anchor sizes range 1/4" to 1" • Unique stainless steel design improves • Standard Kwik Bolt II K anchor performance. • Extra Thread Length Kwik Bolt II in diameter and are supplied with s lin rod couplings. • Anchor size is the same as hole size • Stainless Steel Kwik Bolt II washers and nuts or ro j i for simple installation. (304 and 316) i, • Can be installed in a bottomless hole. • Countersunk Post -Nut _ l • Length identification code for quality • Kwik Tie 1 control and inspection. • Rod Coupling Kwik Bolt II • Extra thread length available for • Stainless Steel Extra Thread Length i " double- nutting, grout pads and • Stainless Steel Countersunk i shimming. I • Special orders available in various materials, sizes, and thread lengths. • Shrink wrapped packaging to protect from moisture. • Complete with nuts and washers. • Conforms to Federal Specification FF -S -325, Group II, Type 4, Class 1. Product Details Collar Wedge Dimple Prevents wedges Prevents Nut Anchor Body from sliding up spinning in Anchor body : ;' ', , - ` the hole — • x 10 Dog Point Washer Wedges Expansion Cone Prevents thread Improved Provides Length Identification damage during wedge design consistent Mark installation ensures more expansion of consistent & wedges reliable fastening Installation Instructions t }��,;:, , mot ' , ;S 'i2: � 1 r .4� wx •r r. tT� '•t.o-:. -% ✓•_`" it, i 1!' r s ..J ` �' i '1w��r�_.� y'4r �a !>d,• . ., ,.., OtlINIMERN '11 -, _N :; Vii; ' A ' •r. r • _ °ir I.-`41; 4 4 .4. -. 4 1 1t: a - ... • "ar '2 '..6' ' '1` . .44 �} a ,,, .... - -- 1--:-,- =. • : " • • . •: , is.:;?..j1.- - :;. - t-r-' i:-..:•:.•-•- !=4.4.1 \ 1. Hammer drill a hole the same 2. Clean hole. 3. Drive the Hilti KWIK BOLT II far 4. Tighten to the recommended nominal diameter as the Hilti enough into the hole so that torque value with a torque KWIK BOLT II, with or without at least six threads are below wrench or up to 4 turns from the fixture in place —the KWIK the top surface of the fixture. the finger tight position to BOLT II works in a "bottom- Recommend the Hilti 2 lb. achieve specified torque hammer to drive anchor into values. less hole. the concrete. Kwik -Bolt Length Identification System Stamp on Anchor A B C D E F G H I J I K L M N O P O R S T U V W X Y Z From 11/2 2 21/2 3 3 4 41/2 5 51/2 6 I 61/2 7 71/2 8 8'/: 9 9' 10 11 12 13 14 15 16 17 18 Length of Up To Anchor But Not 2 21 3 314 4 414 5 514 6 614 7 71 8 8'h 9 914 10 11 12 13 14 15 16 17 18 19 (Inches) In Stamp on Anchor A B C D E , F G H I J K L M N O P O R ST U V W X Y Z From 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Length of Up To Anchor But Not 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 (Inches) Including 81 } 'e Kwiik Bolt II Stud Anchor System ' ' Specification Table Anchor Size 1 Setting Details HKB HKB HKB HKB HKB HKB BD =D drill bit size = anchor diameter 1 /4" 3 /8" 'h" 5 /a" 3 /4" 1" E depth of embedment (min.) 11/2" 1 21/4" 2 3 41/2" DC wedge clearance hole 5 /16" 7 /16" 9 /l6 11 /16 " 1 1 1 2 23/4" 31/2“ 41/4" 6" L anchor length min. /max. 4 7" 7" 10" 12" 12" std. thread length 3 /4" '/8 " /1'/8" 1 11/2" 11 21 TL extra thread length 3" 4" 4" 31/2" /41/2" 3' " /4 41/2" M Installation SS 4 20 30 75 150 200 torque (ft. lb.) KBII min. E 4 20 i 30 75 150 200 guide values KBII std. E 7 25 I 45 I 95 225 350 BMT Min. Base Material 3" or 1.3E whichever number is greater Thickness (inches) - Listings Conforms to the description in Federal Specification FF -S -325, Group II, Type 4, Class 1 for concrete expansion anchors. UL listed, "Pipe Hangers" ( - 3 /4" diameters). International Conference of Building Officials, ICBO Evaluation Report #4627. Factory Mutual listed "Pipe Hangers" 3 /8 KB II w /rod coupler. Southern Building Code Congress International, SBCCI Report #8913 COLA Additional Pending Anchor Program Standard Kwik Bolt II Sizes 41 • ,woo } Hole Anchor ; Min. Hilti Allowable Working Loads Item Diameter , 'Embedment Thread Drill 4000 psi Concrete Qty. Per Number Description (In.) (In.). I Depth (In.) Length ; Bit !Tension (lbs.) Shear (lbs.) ; Box /Ctn. 1 000453597 KB II 14 -134 1 /4 13/4 I 100/900 000453605 KB II 14 -214 1 /4 21/4 1 3/4" TE -C + 1 /4 -6 380 430 100/900 00045306 KB 11 14 -314 1 /4 31/4 100/400 000453621 KB II 38 -214 3 /8 2 1 7 18" TE -C + 3 /8 -6 750 930 100/500 000453639 KB II 38 -3 3 /8 3 100/400 000453647 KB II 38 -334 3 /e 3 1 1V8" TE -C + 3 /8 -6 750 930 100/400 000453654 KB II 38 -5 3 /8 5 50/200 1 000453662 KB 11 12 -234 1/2 23/4 50/200 TE -C + 1 / -6 000453670 KB II 12-334 1 /2 33 %4 50/200 2 11/4" 1450 1600 000453688 KB II 12 -412 'z 41/2 TE- C +1 -12 I 200 50/ 000453696 KBII 12 -512 1 /2 51 i 25 000453704 KB II 58 -334 5 /6 33/4 25/100 TE -C + 5/8-6 25/100 000453712 KB II 58-434 5- a 43'4 23/4 1 2130 2800 i 000453720 KB II 58 -6 5,6 6 25/75 TE -C+ 25/75 000453738 KB II 58-7 5 8 7 • 000453746 KB II 34 -434 34 4 3 _ 20/80 • TE -C + 4 5 20/60 000453753 KB II 34-512 3 /4 5'z 31/4 1' /z" 2670 3470 10/40 • • 000453761 KB II 34-7 3 7 TE- C + -12 I 10/40 000453779 KB II 34-8 ''4 8 . 000454124 KB 11 1 -6 1 6 /: 5/25 000454132 K811 1 -9 1 9 4 2 2 TE F 1 13 4670 7470 5/20 • 82 �,� Product Information . ELC a i , .• • TEXT Threaded Rod Anchoring System Simplify Threaded Rod � }� • , :, � e Product, Selection { � •� � � # b Anchoring with the Elco Selecting the proper HangerMate anchor for Textron HangerMViate® an application is simply a matter of knowing: 0 0. Threaded Rod Anchoring A. The application material (metal, masonry/ o concrete or wood) System B. The threaded rod or component size °_• Attaching threaded rod and components to metal, (1/4 – 20 or 3/8 – 16) = � masonry or wood to support fire sprinklers, piping (up to three inch dia.), Metal Applications QM cable, lighting, HVAC /R systems and the like Tapped to Accept Tapped to Accept has always been 1/4 - 20 Threads 3/8 - 16 Threads 111. tedious, labor- intensive \ ® r� and time - consuming — until now. - ._ � CI Elco Textron's HangerMate threaded rod ti i X 1;1 ® -et anchoring system introduces a new era of L' STED CB " � Y threaded rod anchoring. HangerMate "'" anchors are the easiest to install, most IIIIMIll versatile and highest performing threaded it Meets , T . a rni NFPA 73 4 rod anchors available. Period. R 0 CD ELCO TEXTRON ELCO TEXTRON O CAT. NO. ZE405 CAT. NO. ZE605 CD . : o ;. P a.: ^ i ; • Both anchors sell drill in metal up to 250' Oft in......_......"1 �_� M asonry /Concrete and Wood Applications ct. The HangerMate system will Tapped to Accept Tapped to Accept a save you time and money that 1/4 - 20 Threads 3/13- 16 Threads = ' other anchoring methods \ p i i i ill waste. Simply put, the Elco � e � Textron HangerMate anchoring .i.„... / E% S system delivers better fastening at a lower cost. . . fa% emc • Faster than beam clamps! J � J� A no ,� 3 • No more predrilling metal or wood! j „j • Eliminates pounding or setting of unthreaded �� anchors into masonry! P • Easier to install than powder actuated stud pin ELCO TEXTRON ELCO TEXTRON and coupling nut assemblies! CAT. NO. ZE455 CAT. NO. ZE560 i • Replaces coach screws, hanger bolts, swing Typical HangerMate details and product specifi- connectors and ceiling flanges! cations are available in AutoCAD disk format to help in determining application suitability and • Works in metal, concrete and wood to elimi- anchor selection; contact your Elco Textron nate multiple fastening formats! customer service professional. See reverse for product installation, performance and warranty information h '8= ° « s1.? '.4 , 1 `. i, 4 ...ON'4 .. ,,. :t , ?,^::a,» 1ifY=E� - ,x hyt ,,r^ I ,r,t, F> t '" �:�n'P,k':' tr ...,,:.y E �. !T; •P „ +W§`5 a1^fr „f �.ti; .rr�r i; ",t 'i4 kt - ysfs '�;. '” r - �,.:cL t i Product #P;erfor and. Techn�c al De tai l r Pro • O ,,�,� ,, +'Al•A .ti r>ti,� r,t:_i� v�,�_. Wiz. .5T•,`�. h_.t�„ -�r: fis �s ;..,� > Ka« t �.�. r.:a. ?k ^ r ?Sit •�L1'.4'F�;i! aun.,. w z � n,nn. It,n, e..va r ", - . 8�.:':7e;t�r4rs t � •oak ws,r asv....er,xce :... �? - .'tt.. . .n., 3 - ..,., t Genuine HangerMate installation tool components, used - • Pullout Testing In Steed* • r. with a contractor -grade screw gun, hammer drill or rotary steelTr>are .109• . 123 .155 .170' .t87• 232' 2sa' Unimak! KSI 99 77 79 81 88 86 ea hammer, install HangerMate anchors quickly, easily and Material R8 9s 92 95 97 90 88 85 with single hand cycling for reduced installer fatigue. 1,510 1,860 2,080 3,620 4,250 4.720 4.730 HangerMate installation tool are components designed 1.880 2.090 2.820 2.670 4210 4,118 4.770 P 9 Tested Pullout Values 1,710 ' 1,270 2,600 2,440 3,830 3,960 s aso specifically for installing Elco Textron HangerMate anchors "°" °"°°®°`°" 1,790 2110 3.350 3.640 2.060 3,750 4.780 and operate as an installation system to deliver consistent 1.750 2.100 2.860 3.040 3,820 3,420 4,800 and optimal results. Complete installation instructions are Average ' 7 � '' 2 3,oaz 3 3993 ` p P High Pullout Values 1,880 2.110 3,350 3.640 4250 4,720 5.080 included with each box of HangerMate anchors. tow Pullout Values 1,510 1270 _ 2.080 2.410 2.060 1420 4.730 These values are for the HangerMate anchors installed in the steel thicknesses shown. Metal and Wood Applications For pullout values in steel thicknesses not shown, contact Elco Textron Inc. The tensile PP strength of the threaded rod may be less than these values and must therefore be • 1. Insert 2. Insert determined to be adequate by the end user. • appropriate Elco Textron HangerMate anchors ZE605 are listed by Underwriters Laboratories Inc. • HangerMate a } HangerMate and Undrw erters' Laboratories of Canada for use in steel .155 thick and above. recessed drive '< 'j socket ZE215 unto anchor into drive Pullout Testing in Concrete Pullout Testing In Wood �`' corded screw gun socket. (min. 4.5 amps) or ,0 Material PSI 5,190 Speak Gravity .586 u. p appropriate cordless ; HangerMate Embedment t Depth HangerMate r Screw ti � � � • �. , 1 -3/4' Embedment Depth 1 -3/4 - Average Pullout Value 2.082 tbs. Average Pullout Value 2.300 lbs Pullout Testing In Z Purlin 1 F — - -•-- -- '. 3 Han erMate / ,/ 4. The r- - - r= 9 Eloo Textron Cat. No. ZE605 For Use With 3/8-16 Threaded Rod t anchors drill their HangerMate . l i own holes in metal anchor is now Material Gauge 12 14 16 • 1 and wood installed and Average Pullout Value 1,458 lbs. 1.082 lbs. 700.6 •bs. A-. applications so ready to accept a . el predrilling is threaded rod Or These pullout values are offered only as a guide, therefore, an appropriate safety i unnecessary. component. factor should be applied to these values. Simply position >r- \ ' the self-dolling i-+.- ' - ~�'' -- point of the anchor at the intended pant of installation and . Ini n ortant Produ � & Warren Information! ". with the screw gun operating at C y`.y. approximately 1800 rpm. install the HangerMate anchor. The drive socket's As with all cutting tools and fasteners, normal safety precautions SafetySet feature will help set the anchor flush and then disengage to prevent over- should be observed to avoid electrical installations, other utilities and driving. reinforcement bars; careful use will provide the utmost safety and Masonry/Concrete Applications reliability. - . . . 1. Insert appropriate :• ; :' • • : ..• •; . 2. With the drill in ® T he wearing of safety glasses by users and persons in the vicinity is HangerMate the hammer mode, required by Federal Law. r _ carbide- tipped drill !• drill the full length i � bit into hammer drill jt , of the bit. O Shoulders of installed HangerMate anchors must be flush to the or rotary hammer. metal, masonry or wood substrate materials. HangerMate anchors For SOS -drive drills, b � , use drill bit ZE380; should not be subjected to vibratory or shock loads resulting from v for keyed chuck -type • such applications as anchorings for reciprocating machinery, crane ' AO drills, use Elco \e•�'.• rails or hoists. Textron fanged bit &._ ZE360 installed in adapter LY100 (see ID Complete HangerMate product information and technical application inset). assistance is available from Elco Textron by calling 800 /435 -7213. 3. Slide 4. Insert appropriate This literature was prepared as an introductory summary of the HangerMate HangerMate threaded rod anchoring system from Elco Textron Inc. and is not, therefore. recessed drive - ! `� anchorMate intended to describe all hazards, limitations, warnings, precautions, etc. ` sleeve ZE220 over anchor into the ! . drill bit, locking its d rive sleeve. pertaining to the use of the product. The information and data presented internal hex recess Disengage herein are believed to be accurate and reliable, however, due to the wide ■ i . with the hex collar hammer made variety of possible intervening factors, the suitability of the product for the use of the drill bit. k and engage drill .!�. only mode. intended is the sole responsibility of the user. Specifications and other �\\ information contained herein supersede all previously published material .,. -.. a ;• • • >: o !* 5. Place tip ?:°: "a' 'a.' •:;�' t 6. The installed and are subject to change without notice. ". ". p °' of the HangerMate ° • • ° l' ' HangerMate <... anchor into drilled ve anchor is raw All HangerMate anchors are warranted to be manufactured free from detects hole and drive until ready to accept a in material and workmanship. Under this warranty, Elco Textron will provide. the Saferysef _ threaded rod or at no charge, replacement product for any HangerMate anchors proven to feature seats the I ' component. ganchor and Successive be defective when installed in accordance with our published recommerlda All disengages. installations are tions and in applications considered by us as suitable for this product. This even easier ... simply remove warranty is in lieu of any and all warranties, expressed or implied, and in no case will Elco Textron Inc. be liable for incidental, liquidated or consequential the drive sleeve from the drill bit, drill hole(s) and repeat steps 3 through 5. damages. ■ ^ E lco Textron Inc. HangerMate anchors are made in the USA and ELCO TEXTRON Construction Products Division conform to the Buy America Act Elco / Subsidiary of Textron Inc. 5110 Falcon Road • P.O. Box 7009 Rockford, IL 61125 -7009 HangerMate is a registered trademark of Elco Textron Inc. 800.435.7213 • Fax 815.397.8986 AutoCAD is a registered trademark of Autodesk, Inc. ©1995 Elco Textron Inc. Litho U.S.A. F-5231 - • F.--r • Grinnell concrete inserts MATERIAL: Carbon steel body: malleable iron nut. i , , wedge type concrete insert FINISH: Black or galvanized. fig' 281 SERVICE: Upper attachment for suspending pipe or conduit from concrete ceiling. APPROVALS: The 3 /e inch rod size is Underwriters Laboratories listed and Factory Mutual approved for use with up to 4 inch size pipe while the Y through 3 /a inch rod sizes are listed /approved for use with up to 8 inch size . U pipe. Complies with Federal Specification WW -H -171 E �" 3 °r (Type 19) and Manufacturers Standardization Society Y �1`," SP -69 (Type 18). ' '. ,;! x INSTALLATION: '", ter 4 = - , „;',.=.7. (1) Nail insert to wooden forms. ..,:'-'',,,...,•;-, . (2) Where convenient, reinforcing rods may be placed ,........<-2::.•,,i',''.:'.1,',,4,- , � T ” ��` 6 :�% knockout seals out concrete in the opening through the top of the insert, or short f' ' -,-" during pouring lengths of reinforcing rod may be wired to the insert L F' prior to pouring concrete. However, note that the q� , specified load ratings and approvals are not depen- ': . - •.-: �: dent on the use of any reinforcing rods in contact with the insert. • (3) After concrete is poured and wooden forms are removed, insert screw driver into slot in knockout ;. plate and snap it out. ' ' "` ` (4) The nut may be put on the rod before inserting in the * insert body. Then, turn rod so that elongated nut lies " ;:,. r - .f across the slot; screw rod through nut until rod is ,- , ,_, v: . firmly against the top of the recess. • � .• _ a �l FEATURES: , '' `r °•1 a1 ',E . nut and rod in place o Nut may be put on hanger rod before insertion, avoiding need of locating nut in insert body prior to r.,. inserting rod. ,= l•p• o � k -- \Si�. o Insert nut, when located in position, wedges against the sloping sides of insert, providing greater support • It than if resting on lower edge of the insert body. • :',; • Wedge- shaped body is so held by concrete in com x; pression thus increasing load carrying capacity. • • Easily removed knockout plate. • Rod can be adjusted along complete length of slot. I" �2 , C „ • One body for six sizes of rod. !' - - 3 g I l � ORDERING: Specify figure number, name, size of nut 13 "T 7 ____ 2 : i �.-- -- 2 " � tapping if nut is required. E 4 C I loads e weights �� 7" maximum weight TWO 1 2 32 nut recommended (approx) 16 HOLE . -T I I 1 k, �rt size load, lbw Ibs each EACH E ND __ _ _ 1 , 1 /4 240 .82 L : i l _t t r i n sert 3/ 610 .82 J.* i I" 7 " ROD complete '/2 1130 .86 I 4 THRU 8 SIZE with 3 / 4 1200 .89 3 nut ?. 1200 200 .86 ____ 4 1" 7 /8 1200 i .93 insert only ... ... .69 1 '/l ... .13 � .13 nut "/2 ... .17 only Sys ... .20 . y 3 ,4 ... .17 78 ... .24 ■ Based on insert and nut only. Rating is subject to the condition that the concrete used is of sufficient strength to hold the insert. ph -52 ...p - ,..kh ,F te; :. � ... :.:': ,.. ... i?..... _ +. 1. _ zN ... , 7. a4., f.?.n-� t ..rA „4 .1:�, P }wry _r*'.., . °7 a'�sz .•iwni 'vv W".22..r.�c..« ... ,x..r Grinnell szeel pipe :larn�,� SIZE RANGE: 3 ,4 through 20 inch. • extension pipe or riser clamp MATERIAL: Carbon steel. fig. 261 FINISH: Black or galvanized, furnished black ur,!ess otherwise specified. r: SERVICE: For support and steadying of steel pipe :is- 'I' i k ,Er ?: ers either insulated or bare, cast iron pipe or conduit Also supports pipe covering or insulation. This product w' ? . '� i i s no intended for use with hanger rods. For this accti- �J h :G :ii./ , ,ih , ' ' ' cation refer to Fig. 40 Riser Clam p, pag e 15 P - ''N''''. MAXIMUM TEMPERATURE: 650 °F. APPROVALS: Underwriters' Laboratories listed fcr 1/2 to 8 inch pipe. Complies with Federal Specification WW -H -171 E (Type 8) and Manufacturers Standardization Society SP -69 (Type 8). INSTALLATION: Clamp is fitted and bolted preferably below a coupling or welded lugs on steel pipe. Bcit I A . torques should be per industry standards. Clamo is _ / designed for standard steel pipe O.D. and this must be considered in sizing the riser for other types of dic- ing. suggested torque values shcwn Install using maximum Bugg in technicai data section page ph -179 ORDERING: Specify pipe size, figure number, name. finish 0 loads • weights • dimensions (inches) I size Maximum length 1 size recommended wgt (approx) A stock bolts size Ibe each Toad, + size lb � � 87/0 3 /,e x 1 ?�S x 1 /z 1.1 7 3/,6 ?6X1/2 z /' 1.1 10 /s ' /+e x 1 ?6 x 1'/2 1 250 � 1.6 � z /,s x 1 36 x 1' /z 11/4 1.6 i 10% z 3 /,a x l'/2 1 0'/4 /h e x l 1'/2 3000 1.9 11'/a '/t x 1 1 /1e x 11/2 2 1.9 7 /16 x 11/2 400 /4 x 1 3 /2 500 I 1.9 I 127/6 �! '/. x t Y2 x 2 3' /z 600 2.3 127/s ". x 1 /2 x 2 4 i 50 I 2.4 x 2 '/4 x 11/2 ' /2 '/2 1600 4.0 13 ?i '14 x 1'/2 ;2 x 2 5 1600 4.0 14 , / 14 x 1' /z vs x 2' /z . 6 7.6 18 /z � x 2',4 8 2500 11.1 201/4 ?6 x 2 ss x 2' /z 10 2500 f 16.5 223/4 /z x 2 x 2 2 2700 24 /z x 2 • 12 2700 17.7 , ?4 x 3 14 26 ysx2 /z 16 2900 30.a 28 56 x 21/2 . x 3 2900 I 33.8 ysx2' /z 3,4x3 18 35.0 30 20 2900 • Clamps may have square edges. ph 7 1 � Anchoring Systems • HDI -P Drop-In Anchor 4.3.5 t +w L r, 'u�w� .3.5.1 PRODUCT DESCRIPTION w „ + °`r ,, ,,• ,r y ' , ' . The Hilti HDI PDrop -In anchor is an internally threaded, flush mounted r ..E. wi { � :) y expansion anch for solid and hollow concrete. t * ' , z 3 , ' ,a ,h i Product Features • Short length for shallow embedment depth • Integral lip for use in bottomless holes • Flush installation Approvals/Listings Approvals • Factory Mutual (FM) Guide Specifications Expansion Anchors: Grou V Type ors , for expansion be shield anchors. which A chorstto the be zinc description plated in accordance Specification with ASTM B633, Sc. 1, Type Ill. Type A Sc. 1, ype Anchors shall be Hilti HDI -P anchors as supplied by Hilti, Inc., P.O. Box 21148, Tulsa, OK 74121. Installation: Shell or flush type anchors to be installed in holes drilled with Hilti carbide tipped drill bits. Anchors shall be installed per manufacturer's recommendations. 4.3.5.2 MATERIAL SPECIFICATIONS HDI -P Carbon Steel material meets the requirements of AISI 1110M or AISI 1010 '0Znc plated for corrosion protection in accordance with ASTM B633, Sc. 1, Type III 4.3.5.3 TECHNICAL DATA HDI -P Specification Table Average Ultimate Loads, lb (kN) Allowable Loads, lb (kN) Description Length Bit Size 4000 psi (27.6 MPa) Concrete Hollow Core 4000 psi (27.6 MPa) Concrete Hollow Core in. (mm) in. Tension Shear Tension Shear Tension Shear Tension 800 Shear (3 6) HDI -P 3/8 3/ (19.1) 1 /2 1900 (8.5) 3000 (13.3) 2100 (9.3) 4000 (17.8) 380 (1.7) 600 (2.7) 420 (1.9) 4.3.5.4 INSTALLATION INSTRUCTIONS al i -��'�\ ,ir \\ \\ • � � ��� \ \ ` ..' ... .. . ., .. .. 1/1 . „.:;.„..:,.., ,,, ,... DI , u .-.:.:::,..--s-,..„.,,,--,,,lv„, , III 4 /41 ,.. .:.‘..:„,.._ ,;e: A . __________----. 3. Clean hole. 4. Insert anchor. 5 . Insert setting tool 6. Collar of indentation tting l pill wil 1. Set depth 2. Hammer-drill and strike with mmer drill gauge on drill. hole. hammer until flange of anchor when r , anchor is fully set. properly set. 4.3.5.5 ORDERING INFORMATION HDI -P Products • 1� Setting Tools for HDI -P Anchors Item No. Description Item No. Quantity /Box Description 0 0243554 100 HSD-G 3 /8" - Setting Tool WI hand guard 00247776 HDI-P /8 HST -P 3 /8" - Setting Tool 00253784 117 • . _ _,. . .,.+T�hniral G uide 10/97 f ; • >, - s -7 i Cry ,� �' +-z' at401,1.t`'' °i ill r`t4,1N - y,L S a, • T 7 3 '` -. ' 1 f 1 ]d '.. 1 f 7 t M .st -4 :X x !7 4 �;.:;.�,� j w i Ai , *" M , '` ,3 'r 7>4? v n r '�1 p ,� PS .s t x y r ', 5 „ v _ , r . . tS?t m ,7- `T, 7 t 'µ S az S ^ 'ib`t °i k. S 5 •c y' rc i ' kl` r 'wx ...( „.x.`3410 - ..re�.f,.."�.r 14,,,K 6, .,,,,. �'° P l n fo rma t ion� �� , ;��'��� � � � � W�: �:� . � �� �K:�, � � . , 4; n „, s. „ ... „, . a . � 1 b� 1 Y f > , 3F r .,F r , �" k � d� ?� r;” ( 3.* 4 r '`" .1, i` bI d � "'� r x t�s F Ic .�" • FS -ONE ' hK 4 , r, I k a A e F ' }+s4.. t1 ^ `Yr s � 1 td fW'` 0. 7 s " i Y F a� � 5 h1 } _ T f +� High Performance h� : ° T , ® x z i t 'r � , , y 3. + � �Yg lent 2 1 nt Firestop S�� • to 1 � ,.r `' 3 � 3.. -� ! .� �: , m �,` t i Intumesce r_d " 'lz+ � t ( 9 A Pr description • � ' ° ` { ° ` _, ' ` f 1 °°'`' ;,,,,,:,,>, ' • Intumescent (expands when exposed to fire) firestop sealant that £ ; . 7, r L 9 z , , 1 -`* rotect combustible and non - combustible penetrations for " { d f .r" y,, , �• t:• . i helps p °r up to 4 hours fire rating • ' ; 4 'f.,..; , �' ' ., W } a� { . � , it Y. y o :£, !' r Areas of application = c� 3 : y Iec ation ii • Steel, copper and EMT pipes + , ��w ' • Insulated steel and copper pipes `•`�'�' E`t s u, f • Jacketed cables and cable bundles f - £t4 r"v • • Closed or vented plastic pipes F .L7 , frJ .F,r,. , V; L h:' For use with '` • Concrete, masonry, drywall and wood floor assembl Internationally tested and approved , `- • Wall and floor assemblies rated up to 4 hours 4 _ Examples B S IF,, FILL VOID OR CAVITY MATERI O CLASS IFIED BY ® 1 .; ,' : % .k ' '' -''' 3 1 ' UNDERWRRERS LABORATO INC • FOR USE IN TAOUG APPROVED - Sealing around plastic pipe penetrations in fire rated FIRESTOP YSMS Fa APP eonFn Swoa „1 construction • S EE UL FIRE RESISTANCE DIRECTORY „ aee.ua Caoa• ar o e ' r , i fieY7 �'x r ? -,ta System/Product advantages advantages p. memba w Y l S'fi�' • Protects more than 95% of all typical firestop applications • Easy to work with and fast cleanup International Z • Quick sealing of remaining gaps Council f; • Can be repenetrated when laying new cables FSpONE s Intumescent Firestop Sealant - . 4. ' ; Ordering } >� � Volume Item No. Description Color Package contents ,,,, xy • 4- ' }k FS -ONE, tube red 10.1 oz. (300 ml) 18 in 00259579 FS -ONE, foil red (Qty 20) 20.2 oz. (600 mil 36 in' 00259578 1 025 : '' r FS-ONE pail red 5 Gallons (19 liter) 00055205 CB 200 PI- 300/310 ml Dispenser 00024669 ,' r 600 ml Foil Dispenser .. ' -,,0 x4: ! yt • - Confidence Value ` , Simplicity 1- 800- 879-80 - MILT /. 4 f ��� �i y r }; i ; � Un, � . f s � + r , , }a t �� 4',"'„,' a 1 fi . Installatton� + ., t .. ; u K k � ' , v a '� f3 1 4.A } r ' P i }� " 0`.} " ,, ' .'t' , 1 , ,.. 7 +..el ;ri,,. -, c P7,', ° • rte ., sh;;n ;u �u ... , I, . �.;x , sl y,r :,..1a. d"„ ..._. ,rte. .,Mac: > , � ...� -w e,.�.Ga��3�._ . u�?l; r.a. Y 1 FS -ONE Technical Data FS -ONE Intumescent Firestop High Performance at 73 °F (23°C) and 50% relative humidity) ®pp ¢ Sealant Chemical basis: Water -based intumescent acrylic dispersion Intumescent Firestop Sealan` Density: Approx. 1.5g /cm' Color: Red Product description Working time: Approx. 20-30 min • Intumescent (expands when exposed to fire) firestop sealant that Curing time: Approx. 14 - 21 days helps protect combustible and non - combustible penetrations for Shore A Hardness: Approx. 35 up to 4 hours fire rating Movement capability: Approx. 5% Intumescent Activation: Approx 250 °F (121°C) Product features Expansion rate (unrestricted): Up to 3 -5 times original volume • Smoke, gas and water resistant Temperature resistance (cured): -40 °F ( -40 °C) to 212 °F (100 °C) • Contains no halogen, solvents or asbestos Application temperature: 35 °F (2 °C) to 100 °F (38 °C) • High fire rating properties Surface burning characteristics: Flame Spread: 0 i • Water based, easy to clean (ASTM E 84 -96) Smoke Development: 5 ' Tested in accordance with Approvals • UL 1479 IC80 Evaluation Service, Inc. Report No. 5071 • ASTM E 814 California State Fire Marshal Listing No. 1200:108 1 • UL 2079 City of New York MEA 326 -96 -M City of Los Angeles Research Report 25188 Installation instructions for FS - ONE ,_ '� FI '� is 4 Ii*EI - � r '" u Ifle '.,:: 'it r '�J- � ff d , -...t . X1 .1 :' l ti :, . 'r. , : : , �e _ } , • . ,. y'' v, + 1. Clean opening. 2. Pack mineral 3. Apply FS ONE. 4. Smooth FS -ONE. 5. Leave completed 6. Fasten identification wool. (If required) seal undisturbed for plate (if required). . 48 hours. Opening Notice about approvals 1. Clean the opening. Surfaces to which FS -ONE will be applied Check that the penetration has been sealed according to the specified should be cleaned of loose debris, dirt, oil, moisture, frost and drawing in the UL Fire Resistance Directory or Hilti Firestop manual. wax. Structures supporting penetrating items must be installed For further advice, please contact Hilti customer service. Refer to in compliance with local building and electrical standards Hilti product literature and UL fire resistance directory for specific Application of firestop sealant application details. 2. Install the prescribed backfilling material type and depth to Not to be used... obtain the desired rating (if required). Leave sufficient depth for • For high movement expansion joints applying FS -ONE. • Underwater 3. Application of firestop sealant: Apply FS -ONE to the required • On building materials which bleed oil, plasticizers or solvents depth in order to obtain the desired fire rating. Make sure (impregnated wood, oil -based seals, green or partially vulcanized rubber) FS -ONE contacts all surfaces to provide maximum adhesion. • In any penetration other than those specifically described in the Hilti For application of FS -ONE use a standard caulking gun, foil pack Firestop Manual or the test reports gun, bulk loader and bulk gun. With FS -ONE buckets, Graco type sealant pumps may be used. (Contact pump manufacturer for Safety precautions proper selection.) • Before handling, read the product and material safety data sheet for 4. Smoothing of firestop sealant: To complete the seal, tool immedi- detailed use and health information. ately to give a smooth appearance. Excess sealant, prior to • Keep out of reach of children r, curing, can be cleaned away from adjacent surfaces and tools • Wear suitable gloves and eye protection • si with water. Storage ! ,. ?H. 5. Leave completed seal undisturbed for 48 hours. • Store only in the original packaging in a location protected from 11 r ,' h 6. For maintenance reasons, a penetration seal could be permanently moisture at temperatures between 40 °F (5 °C) and 86 °F (30 °C). marked with an identification plate. In such a case, mark the iden- • Observe expiration date on the packaging. tification plate and fasten it in a visible position next to the seal. M`TI. 5 1-800- 879 -8000