Plans !►• MODULE VOLTAGE RATINGS RECEI Voc: 33.2 VDC Vpmax: 26.6 VDC DEC 2 2 2010 *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN THE DC 2 STRINGS OF 10 MODULES CITY OF TIGARD STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. (20) KYOCERA # KD210GX -LPU PV Module; 210W, 189.8W PTC U (4)AWG #10, USE -2 /RHW -2, • ; L DIVISION I (N) ARRAY GROUND PER 690.47(D). NOTE: PER I .. a a n a Dc= _ _ _ ( 1 ) AWG #6, Stranded Bare Copper EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE ; �J °J" " ° I • Voc = 332 VDC T REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE. ! I pc' ; • Vmp = 266 VDC 1 _ _4_ - _ _ I • Isc = 8.58 ADC • AWG #6, Stranded Bare Copper ( 1) GEC , I • Imp = 7.9 ADC 1 Ground Rod; 5/8" x 8', Copper ( 1 ) ' ' V_ • I I I f *- ( 1 ) SHOALS # STG.ICU.M4.F L Connector; MC4 U -Joint Connector, Female ( 1 ) SHOALS # STG.ICU.M4.M 0 I I Connector; MC4 U -Joint Connector, Male EGC �DC -� DC� LOCATED UNDER ARRAY I (E) 200A MAIN ELECTRIC SERVICE PANEL i i 2 AWG #10, USE-2/ RHW -2, Black NO MAIN BREAKER (1) STABLOK # NA225 FRONIUS # ICI 4000 (1) - I ( ) # FEDERAL PACIFIC ELECTRIC PANEL 1410 -14 -200 Breaker; 25A, 2 -Pole Inverter; 4000W, 240V, 500VDC, 94% EFF. , , (1) AWG #6, Stranded Bare Copper EGC LOCATED AT END OF BUSSING �� (1 )Conduit Kit; 3/4" EMT C (E) WIRES AND CONDUIT � _ ( 1 ) AWG #10, THWN -2, Black I I • Voc = 332 VDC I Cf J AC DISCONNECT - 1 AWG #10, THWN-2, Red N ' ' PER ART. 690.17 ( ) # r - - - I ' • Vmp = 266 VDC ®BOTTOM OF BUSS - (1 )AWG #10 THWN -2, White NEUTRAL INVERTER • i I (E) LOADS • Isc = 17.16 ADC - ( 1 ) AWG #6, THWN -2, Green GEC /EGC GFP I LINE Imp = 15.8 ADC I Elt I AD S - (1 )Conduit Kit; 1/2" EMT I ❑N GND Z o to Im `+I I Z C)C) 6) - I t I i� Vmp = 240 VAC i j I I , ( 1)SQUARE D # HU361RB I ` } • + . � A Imp = 16.67 AAC I i i EGC DC -� DC* LOAD Disconnect; 30A, 600V, NEMA 3R \ I IC El 0 TOP L _ _ _ _ I _ _ _ _ _ r _ -4 _ 1 = I I Q �. BOTTOM L1 L2 I LDS LE_ _ _ J OFFICE COP Y •� L N N DC* o EGC /GEC - EGC /GEC z - 0 _ _'I ( 1 ) AWG #10, THWN -2, Black s C T } ' `g- (1)AWG #10, THWN -2, White TO 120/240V #8 JUMPER SINGLE PHASE - - - (1 )AWG #10, THWN -2, Green EGC UTILITY SERVICE AC & DC - (1 )Conduit Kit; 1/2" EMT ' DISCONNECTS ARE • Voc = 332 VDC COOPER # B Line Meter Socket 011( 1 ) - INTEGRATED INTO • Vmp = 266 VDC �) AWG #6, Solid Bare Copper (1 ) i Meter Socket; 125A, 4- 14AWG, Ring Type THE INVERTER • In = 17.16 ADC BOND (N) #8 EGC /GEC TO BOTH (N) GROUND • Imp = 15.8 ADC ROD AND (E) GEC WITH IRREVERSIBLE CRIMPS PER ART 250.64(C) AND ART 250.66(A) Ground Rod; 5/8" x 8', Copper (1 ) CONFIDENTIAL - THE INFORMATION HEREIN MARKET: MODULES: PREMISE OWNER: DESCRIPTION: JOB NUMBER: ` �IIe� CONTAINED SHALL NOT BE USED FOR THE REST (20) KYOCERA # KD210GX -LPU DAVIES, BRIAN DAVIES RESIDENCE J8- 972059 00 '= BENEFIT OF ANYONE EXCEPT SOLARCITY INC., DES/GN: 12025 SW SPRINGWOOD DR 4.2 kW ROOF MOUNT PV SYSTEM MOUNTING SYSTEM: I�,' SolarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN LH SOLARCITY CANOPY C AND RAIL PART TO OTHERS OUTSIDE THE RECIPIENT'S DATE ORGANIZATION, EXCEPT IN CONNECTION WITH PROECT MANAGER: INVERTER: TIGARD, OR 97223 12/6/2010 THE SALE AND USE OF THE RESPECTIVE * (1) FRONIUS # IC 4000 393 Vintage Park Drive, Suite 140 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE • PAGE NAME: SHEET: REV: T:(650) 638 Foster City, I C 638 PERMISSION OF SOLARCITY INC. PPA 9716450489 SINGLE LINE PV 5 (888)- SOL-UTY(765 -2489) I www.solarcity.corn ' deg Conductor Sizing per Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous ELECTRICAL CALCULATIONS current per Art 215.2(A)(1). Module: Mayo er 141)2G)f� -I!PU 18918'.Inv Pvir .W PTC -. Voltage Drop:Calculations Version.5`7.0 b. Conductor must have (after corrections for conditions of use) >= I' nverterl Fr " o : ntus I u,1 M1.iC;'4 4(000; n, 68 Vdrop:= . ' Imp " ) ` Z' (Resistance). 1 (Vntp). continuous current per Table 310.16. Module: r ,. Imp "(A) 'Max: Length (ft) Wire Irrrerter'2. ., :: ri . � Strin ' 7.-9: 50. C AWG 10 at Max Ave Hi: 00, deg F alll Module: Vdrap = (7:90;A '- 100,ft t 0 :00124 =Ohms) 'f 244' = 040% c. Evaluate conductor temperature at terminations per 110.14(C). ._ �� . � � 11)v o. 2 1 t I ,3: � „� a����,� �� Branch: I 15:'8 I 75` IG AWG iq at Max Awe Hi 30' 4t F Ampacity of wire derated for conditions of termination must be Modules Vdrap = (15 :60 A 150 ft •'0:00124 - 'Ohms) 4. 244.Vi'= ii >= continuous current *1.25. All string terminations are rated at Inverter.¢. tliTrtwiNdEigrA TM, _ Tetalvoitage•dro l fir DC "conductors 11.61% 90' C. Inverter: I '16 :6T' I 15' ' IC AWG 10 at240V Taal:_ W modules Total :Inv Pwr Q(4101i1 J 68 PT Vdrap = (16.67A IA. 30 ft *•: :0 00120 Ohms)' F 240 V 025% 2. OCP Sizing per Art 690.8(6)(1) Photovoltaic Mo dule :Flectrical`Specifiications:. Total STC,; ,5 ,4'2 Combinedl 16 :67 I 0 IC AWG ' 1Oi at 240V a. Round up to next size per Art 240.4(6) Voc= az V deg F_� AT r'C. Vdrap = (166T A ` 1111. *0 00 ( 240 V 0:00% Vrnp= V. Record Low Temp:, - ' 8 -11 D Total voitage'drrep in At conductors 025% , Isc= QggiA; Max Avera T 80 r?X.i( Total, voltag drop in _AC'andl DC °conductors ='1' :86% 3. Conductor Sizing per Art 690.8(8)(1) Imp= T7. Q. • Record Hi Terrip , 1 a.; 'MN a. Conductor must have 30 deg. C ampacity >= 125% of continuous Tvoc= 4ji 12 Wfeg;C current per Art 215.2(A)(1). ti t"= 7 1 th Jdeg C 1 Stung T A and 2 Combined Strings`Tya&A 'Voc.Correction Method Man ilya di Branch.CircurtTyrie -A I i 10Ornodules,per`series stung b. Conductor must have (after corrections for conditions of use) >= Fra"�`�,iftl�l TUI ,_ G ' 4 ,_ 21strings "per branch 1 way:wire leng'th;I le ft 0 C + 1fiD21OG - Inverter Min Vdc Inp M, Vd continuous cur per Table 310.16. Vim= - J v' Min Vmp atav9ax Temp Vdc ;Vo 3 V Vine= M V a x Voc: at MiT "; n em �- Vdc Vmp L` • V = c. Evaluate conductor temperature at terminations per Art 110.14(C). Is 4p, A Inverter Max •Vdc Input t n; Vdc l ist 'a 9C3 A Ampacity of wire derated for conditions of termination must be I rig A. Max String:Si e: 553. 14= aEl A >= continuous current *1.25. All branch terminations are rated at icons - - r0 1 A Art .690 :8(A)(1), 1 =way wireIength, _ Ice Zi 4 A ,Art 69 0�6 (A )(1 ) 75' C m min. 1aa Try A' -', '0 ' USE ' 2'a t.90 deg C Table 310:16 3:a Try C AT 0 THWN= 2/USE2 at;90'deg C: Table;310:15 Icon1-' 1 25 = (Amps) r. 4. OCP Sizing Icons 1:25= (Amps) 0W 30deq.0 ampacity -= I l 3.0 deg C;Tampacity= 4:1 I 3 b Icont (Amps) ' Elila a. Round up to next size per Art 240.4(B) 'Lb Icons (Amps), 1'017 Start ampacity Start apacity 4:90 m 0 Tep. derate (% m -F) ON 5. Conductor Sizing per Art 690.8(B)(1) Temperature; derate (3/4=F) larB Cridt =fil derate (%4) 11 a. Conductor must have 30 deg. C ampacity >= 125% of continuous Canduit fill derate (% 9 Derated ampacity •:.4 I current per Art 215.2(A)(1). De rated ampacity Zap) h • Tamil Terin'2 Temp table . Tamil 75degC 1.c Icont1.25= (Amps) 4 1 3 :c Icont *1.25= (Amps) ..EilJ aaal b. Conductor must have (after corrections for conditions of use) >= Ampacity Ampacity X k continuous current per Table 310.16. I I c. Evaluate conductor temperature at terminations per Art 110.14(C). 2- .icons" ]:25:= (Amps) 03>rA 3 :d OCP size NEI3 , Ampacity of wire derated for conditions of termination must be OCR size:= 15 Combined_InverterOutpuf >= continuous current *1.25. All inverter output terminations are Service Voltage= 240 Volts _ rated at 75' C. InverterType A Outpu Total.lnverter Power= 4000 Watts 1 way wifelength:: t)''ft Traniu" s° IG4000 r'r ?wr °',' - a`f t =way w ire length ,L 1S Icont.= # i t inverters °max inverter cu rrent: Art 690,•8(A)(4 Icont=- 16$9 A • A. t,686 690 8(A)(1) leont = (Amps) NM 6. OCP Sizing 4 Icont 125 = '(Amps) LA2411 A Art'690'.8(BX1) 6' Icont "1 25 =- (Amps)' ..g2 6: Art 690.8(6)(1) a. Round up to next size per Art 240.4(B) OCP.size gi A Art ;240_6(A) OC A: Art. 240.6(A) 5.4 Try ? Wt 0 THWN- 2'.at,90i deg C Table:310.16 7'.a Try C Al G 1 THV1lN -2;at 90 deg C °Table 310:16 7. Conductor Sizing per Art 690.8(6)(1) scant • 1,25= (Amps) Ican•1 t *1:25= (Amps) X83 a. Conductor must have 30 deg. C ampacity >= 125% of continuous 30 deg G arri = I I 30 deg C am 4D 5.b !cant= (Amps) C . ''1 %7 7.b i(A) 1€t'S7 current per Art 215.2(A)(1). Start ampacity C Startaapacity: - 0 Temperature derate(% =F) 01�`il Temp: derate (ak t.) QgC b. Conductor must have (after corrections for conditions of use) >= Gontluit5II.derate ( #) and. fillderate.(% ) 4) continuous current per Table 310.16. Deiatei ainpacity 3.6.,; I Deratedampacity 6._4_ I 5.c Ico'nt *1 25= (Amps), V __2&83 7.c I-Cone1 25- (Amps) nig C. Evaluate conductor temperature at terminations per Art 110.14(C). Am Ampacity ' Ampacity of wire derated for conditions of termination must be I I >= continuous current *1.25. All inverter output terminations are rated at 75' C min. CONFIDENTIAL -THE INFORMATION HEREIN MARKET: MODULES PREMISE OWNER: DESCRIPTION: JOB NUMBER: %„k� CONTAINED SHALL NOT BE USED FOR THE RESI _ (20) KYOCERA # KD210GX -LPU DAVIES, BRIAN DAVIES RESIDENCE 13- 97205.9 00 : . BENEFIT OF ANYONE EXCEPT SOLARCITY INC., DESIGN: MOUNTING SYSTEM: P SolarC- �ty NOR SHALL IT BE DISCLOSED IN WHOLE OR IN LH SOLARCITY CANOPY C AND RAIL 12025 SW SPRINGWOOD DR 4.2 kW ROOF MOUNT PV SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'S DATE o ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: INVERTER: TIGARD, OR 97223 12/6/2010 THE SALE AND USE OF THE RESPECTIVE * (1) FRONIUS # IG 4000 393 Vintage Park Drive, Suite 140 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE PAGE NAME: SHEET: T:(65o) Foster , r City, CA F:(650) 38 - 1029 PERMISSION OF SOLARCITY INC. PPA 9716450489 ELECTRICAL CALCULATIONS PV 6 (888)- SOL- crrY(765 -2489) I www•solarcity.com PV MODULE i G4. c e 7 NW pir r- ,,,a �a� K D2IOGX -LP,U t , C Ky.00: o ELECTRICAL CHARACTERISTICS f 'L° Qe , tt VS 'c''_. Volta ch of Photovolt Cu Volt c har a c ferlstic s : of Photovoltak i r t e , ": Moduli KD2IOGX =LP1,1 at various:cell temperatures Module .KD21OGX LPUatvarlouslrradlance levels. e �' J" Cl9TTING ED TECHNOLOGY ! � "'�""`'"""" `�`'°°� £ I O TT WA A.,, a; pioneer with;• 35 years in solar Kyocera . ;demonstrates ,. leadership In the development of solar energy 'products ' � pia HIGH EFFICIENCY MULTIGRYSTAL Kyocera s Karzen. Phio mmi losphy, co to' continuous PH0 a a LTAIC MODULE improvement Is;;shown b repeatedly achieving world record 3 s ` - °- °�'�°` cell efficiencies 1 * ' � . IR. f a i T 1 ,Kyoce rarQuality B uilt In:' 1, 1 1 i .- New frame technology allows forend mountirig withr2400"Pa s ` � \\\\\ (50 psfror wind speeds of4'130 •mph (ASTM E1830) ;and traditional rnounUng unifier 540Q<P.a:( tosupport ° m : °o; I m; ,o p ---1---- I i I rncreased snow,load M. "" °'M' uv stabilized ,aesthetically pleasing black4anodized frame,- , • �� ( i I - SU ppor`teil by mayor mounting structure manufacturers SPECIFICATIONS" ! ! Easily accessible grounding points on.all� four corners I I fast Installation U Physleal Spgciflcetlons (hit m!� - Proven, junction box technology I I ualit locking . lu in connectors to rovideAsafe;, &,, uick ?� iPs s ) +� ~1Y} I tonne gF g - . P " o, Cilon,3,' mom) ' atiaqi: ee(a�) , ~ I i Kyocera manufactures" and ' =assembles solar c'ellsGand "modules 8 at its , own worldwide production sites using a true vertical 7 -�U integration process This superior approach gives. Kyocera complete control over�,'every•step ;of the manufacturing process, producing modules: with the industry 's tightest" power'" tolerance, 2 - �g Fo � IZi(�X NEC 20O8,Compllarit' pm roising,high quality and efficiency. — 3 r UL,1703,- CI8SS'C Superior• Built In Quality IEC 61215 Proven 'Superior Field. Performance: . T ight Power Tglerance , c � 1 1 25 Year Warranty ,5 'Year Work manship,Warranty- +:13Itai31100 01e10. 3eto.) `E Specifications • Ebeidcal hofmmerhs ether et>oaea Mat cemdmar' • Gm X f � I I - � � ' i I Maximum Power. (Penn) 210W l+sw /-ovO' Nunh& Per Module 154. • . _ +' ' fr f '� z i i Ma mmm� Power Wool Pa $V T - .--1"' a - — �� ds .. . ` n j 7 t Rodman Power Current orpo `7.904 �tibduYQrheedlebe r l' I r J i ,1 Length ,Wiidth X Depth 9 fr t *I1tid ,_ j J� r-/ t / r t iir' ,rr)/ fir` W ..,, _ .� , . j , r n /Il i : / 4,-."7"9. LL — .. - u Leng BMA x 71 � . �.,,,�► r - JJ/J -r,.-/- r r? , F, f. . r�7j ; • ,t J is Ir -1 4, t— I h>mi.. n, eai nt - 120ht1 ?iV /t CeYk I �Itif 14>) jY '�� f � A /f .: y C 1 Y j J � J > ° _/ J' l t ! L / / J, _, / / 7 ' _ _ ,. � , � O t � ' �Y ` J•+F . { `.l , , _ ,. w = � / 7 ' ` j� j < ' I empe sure �tim it of Iii b'.1 1V'A rci : • Buz � . ® _ ` 4 e� 4. [_ �. 'l * = /�_,.. J - „/ _T f „ %i - r //,„„....,_ f � / I , 7 ■ftw lwww. ....ww ww011 o,,, XWldihhXDeptff r / - , J - oecww.t _ IPCode PO A 1r 4 i 77� - ' -A; . j A r _ _ � � ' f Maximum Poaiervan nr�a 2aav , , • od„e. / 2- `tea /�—'' i / - - � L j A f -- - Maximum i Power.G m m i 01140 13.32A £ > . .. �y f - : 7 v /�� /" 1 / / Tr / -- _ _ 7` f r . / — fL' 1 n Chid h6e) 30.0V 'Dp9rltiro'T )ue - �Wt:� -9g� . t� ; r �' J` � �./�/ ms' i r ' 7 ` f / ISO, BOOland.I90 lAOOiGtirbfied;arid pad I I /AI fhb aWundonod h�o a . s ir ' ! i �? = / / / i l / - Z � / / / I ./ - . Er SOLAR b KYOCERA ,,r'( 8oa223795e0taB free BO06232329fax, CONFIDENTIAL -THE INFORMATION HEREIN MARKET: MODULES PREMISE OWNER: DESCRIPTION: JOB NUMBER: ` %,‘11‘ ' CONTAINED SHALL NOT BE USED FOR THE RESI (20) KYOCERA # KD210GX -LPU DAVIES, BRIAN DAVIES RESIDENCE JB- 972059 00 '- BENEFIT OF ANYONE EXCEPT SOLARCITY INC., DESIGN: „ `S MOONING SYSTEM: 12025 SW SPRINGWOOD DR 4.2 kW ROOF MOUNT PV SYST olarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN LH SOLARCITY CANOPY C AND RAIL PART TO OTHERS OUTSIDE THE RECIPIENTS DATE ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: INVERTER: TIGARD, OR 97223 12/6/2010 THE SALE AND USE OF THE RESPECTIVE * (1) FRONIUS # IG 4000 393 Vintage Park Drive, Suite 140 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE PAGE NAME: SHEET: REV: Foster City, CA 94404 PERMISSION OF SOLARCITY INC. PPA CUTSH PV (888)- 2489):iI www.soarc9 9716450489 7 ycom . - , INVERTER , FRONIUS IG FRONIUS IG 4000 / 5100 / 4500 -LV - Specifications - -_ DC Input Data FRONIUS IG 4000 FRONIUS IG 5100 FRONIUS IG 4500 -LV Recommended PV power 3000 - 5000 Wp 4000 - 6300 Wp 3600 - 5500 Wp .. Max. DC input voltage 500 V 500 V 500 V Operating DC voltage range 150 - 450 V 150 - 450 V 150 - 450 V Max. usable DC input current 26.1 A 33.2 A 29.3 A AC Output Data FRONIUS IG 4000 FRONIUS IG 5100 FRONIUS IG4500 -1N Maximum output power ■40° C 4000 W 5100 W 4500 W . Nominal AC output voltage 240 V 208 V Utility AC voltage range 212 - 264 V (240 V +10 %/ -12 %) 183 - 227 V Maximum AC current 16.7 A 21.3 A 21.6 A Maximum utility back feed current 0.0 A 0.0 A I 0.0 A Operating frequency range 59.3 - 60.5 Hz (60 Hz nom) Total harmonic distortion < 5 % Power Factor (cos phi) 1 g General Data FRONIUS IG 4000 FRONIUS IG 5100 FRONIUS IG 4500 -LV 2 Max. efficiency 95.2 % 95.2 % 94.4 % i Consumption in stand -by < 0.15 W (night) Consumption during operation 15 W 3 Enclosure NEMA 3R Size (I x w x h) 28.4 x 16 ;5 x 8.8 in (720 x 418 x 223 mm) o Weight 42 lbs. (19 kg) a Ambient temperature range -5 to 122 °F ( -20 to +50 °C) Cooling controlled forced ventilation Integrated DC and AC disconnects standard UL approved DC & AC disconnects - Protections Ground fault protection Internal GFDI, in accordance with UL 1741 DC reverse polarity protection Internal diode (standing protection Internal, in accordance with UL 1741, IEEE 1547 e, s Over temperature Output power derating E g Surge Protection Internal DC & AC protection. Tested to 6 kV ° I Compliance - E e Safety U L 1741 g.'13 EMI FCC Part 15; Class A & B Anti- Islanding protection UL 1741, IEEE 1547 e a Ground fault detector and interrupter Compliant with NEC Art. 690 requirements, UL 1741 S Miscellaneous - Maximum AC over current protection Two -pole, 30 A circuit breaker 3 / AC wire sizing Use maximum AWG 6 194 °F (90 °C) copper wire t DC wire sizing Use maximum AWG 6 194 °F (90 °C) copper wire s; AC disconnect 32 A S 8 DC disconnect I 40 A ° Et Warranty I 10 year Premium Warranty is Standard t 1 . y Vi Distributed by 1-/Cf171-L1-5" 2 E S E -' E Z i'+ Fronius USA LLC s g Solar Electronic Division - • 10421 Citation Drive Suite 1100 Brighton, Mi 48116 Phone: 810-220-4414 Fax: 810-220-4424 • E -Mail: pv- us@fronius.com o s. • www.fronius- usa.com • _ S - _ - / 4 - N CONFIDENTIAL - THE INFORMATION HEREIN ` MARKET: MODULES: PREMISE OMNER: DESCRIPTION JOB NUMBER: �� /‘ CONTAINED SHALL NOT BE USED FOR THE RESI (20) KYOCERA # KD210GX -LPU DAVIES, BRIAN DAVIES RESIDENCE JB- 972059 00 S ,: BENEFIT OF ANYONE EXCEPT SOLARCITY SW SPRINGWOOD DR 4.2 kW ROOF MOUNT PV SYSTEM TY INC., DESIGN: MOUNTING SYSTEM: Ii' S olarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN LH SOLARCITY CANOPY C AND RAIL PART TO OTHERS OUTSIDE THE RECIPIENTS DATE: a ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: INVERTER: TIGARD, OR 9722 12/6/2010 THE SALE AND USE OF THE RESPECTIVE * (1) FRONIUS # IG 4000 393 Vintage Park Drive, Suite 140 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE • PAGE NAME SHEET: T:(650) 63ster City, , CA 94404 0 638 -1029 PERMISSION OF SOLARCITY INC. PPA 9716450489 CUTSHEETS PV 8 (888)- SOL- ITY(765 -2489) I www.solarcity.com