Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT III Q ' COMMUNITY DEVELOPMENT Permit #: FPS2011 -00089 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 07/22/2011 Parcel: 1 S 126CA00100 Jurisdiction: Tigard Site address: 9225 SW HALL BLVD F Project: Ideal Image Subdivision: FAIRVIEW PLACE CONDO Lot: 20 Project Description: Fire alarm. Contractor: T & L COMMUNICATIONS INC Owner: GREENBURG CORNERS LLC PO BOX 87387 BY MENASHE, R BARRY VANCOUVER, WA 98687 -7387 621 SW ALDER, SUITE 605 PORTLAND, OR 97205 • PHONE: 360 - 737 -9725 PHONE: FAX: 360 - 737 -9648 • FEES Description Date Amount Specifics: Permit Fee - COM 07/13/2011 $112.96 12% State Surcharge - Building 07/13/2011 $13.56 Type of Use: COM Plan Review - Fire Life Safety - COM 07/13/2011 $45.18 Class of Work: ALT Type of Const: IIB Info Process /Archiving - Sm Sheet (up to 07/13/2011 $6.00 Occupancy Grp: B Height: ft 11x17) Stories: 1 Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Standpipe Required: Hazard: Density: 0 Design Area: 0 K Factor: 0 Commercial Fire Alarm System: Fire Alarm Required: Yes Alarm Type: Automatic Pull Station Required: No Smoke Detectors Req: Battery Cates Provided: Yes Cut Sheets Required: Yes Total $177.70 Valuations: Required Items and Reports (Conditions) Sprinkler Valuation: $0.00 Residential Square Footage: 0 Fire Alarm Valuation: $4,000.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notifi . '. - Those rules are set forth in OAR 952 - 001 -0010 through OAR 9520 '9r You may obi a copy of the rules or direct • estions to OUN • . g 503.232.1987 or 1.800.332.2344. Issued • : • / / Permittee Signature: �/�` L7 1 7 l- Call 503.639.4175 by 7:00 a.m. for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. • Fire Protection System Building Permit Application FOR OFFICE USE ONLY �® `� City of Tigard c' Received Permit No.: —' ► ° 13125 SW Hall Blvd., Tigard, �I ^ 1 1 Dat e/B : �/' L• If � . ard OR 97223 `O Plan Review� g + 3 �� . 3 ` Phone: 503.639.4171 Fax: 503.598.1960 0.. ao Date/B : . /� ��� Other Permi r TI G A R D Inspection Line: 503.639 J '(\�' P` ate ReadyBy: /� �� = See Page 2 for Internet: www.tigard- or.gov \� OC ` 1 1 t .tiff thhod:r(/C /� - Supplemental Information G - \ a ►>I / ■ //1Z r TYPE OF WORK / QU it DATA ND 2- FAMILY DWELLING ❑ New construction El Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ® Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. El 1- and 2- family dwelling © Commercial/industrial Valuation: $ El Accessory building ❑ Multi- family Number of bedrooms: ID Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 9225 SW Hall Boulevard New dwelling area: square feet City /State/ZIP: Tigard, OR Garage/carport area: square feet Suite/bldg. /apt. no.: F : I Project name: Ideal Images . • . Covered por0 area: . square feet Cross Street/directions to job site: • _ v Deck area: ` square feet Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: I Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. Installing a Fire Alarm System Valuation: $ 4,000.00 Existing building area: square feet New building area: square feet ❑ PROPERTY OWNER ❑ TENANT Number of stories: Name: Type of construction: Address: Occupancy groups: City /State/ZIP: Existing: Phone: ( ) Fax: ( ) New: ❑ APPLICANT ❑ CONTACT PERSON NOTICE Business name: T &L Communications, Inc. All contractors and subcontractors are required to be Contact name: Ross Bushaw licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: PO Box 87387 jurisdiction in which work is being performed. If the City/State/ZIP: applicant is exempt from licensing, the following reasons Y Vancouver, WA 98687 apply: Phone: ( 360 ) 737 -9725 Fax: : ( 360) 737 -9648 E - mail: office @tl- communications.com CONTRACTOR BUILDING PERMIT FEES* (Please refer to fee schedule) Business name: T &L Communications, Inc. Permit fee: Address: PO Box 87387 City /State/ZIP: Vancouver, WA 98687 State surcharge (8% of permit fee): FLS plan review (40% of permit fee): Phone: ( 360) 737 - 9725 I Fax: ( 360) 737 - 9648 (Due upon application.) CCB lic.: 67787, Portland Metro 6981 Total permit fees: 1 77, '70 Authorized signature: � Amount received: / 77 , 70 This permit application expires if a permit is not obtained Print name: Larry Bushaw I Date: 7/11/2011 within 180 days after it has been accepted as complete. * Fee methodology set by Tri- County Building Industry _ Service Board. „� n _ IA BuildingWermitsWPS- PermitApp.doc 0323 /06 440- 4613T(11/02/COM/wEB) G(X �' y U4 -CX"J 1 i : . aa o' s•• P-6 v1' s' s' ens' Iva• e-0 ° a I RELOCAlE 130371146 P � ''JUL 13 2011 TO -'I :/2 . art 14/ CITY OF TIGARD I C. �® � , 4 A - 18/ F8, • CORR!.• ® © EOL 2 BUILDING DIVISION V ��,, � v, I // �� �� .T. - .. rrpppp a • 0 s ©� 15 � ' 'v' �4i? 11 © 10 110 p �� FACP Imo" I3 so 1 ,,,,,,,,,,,,,,,,,, „,,,,,,,,,,,,,,,,,,, -- ,,,,,,,,,,,,,,,,, „,,,,,,,,,,,,,,,,, „.,.., „ „,,,, — LEGEND - I tr = y �� �I 11. ∎ ∎. m I I- � �/ ® 18/2 E 1 o Roa+ n � p N F S� I NE. • © 5 F RODI Gr ,41 114 0 0 _ I ? � . f l % S I S HORN S TROBE - - SYSTEM SENSOR PC2W • 4 /_r j) 1 STORAGE / O % ■. © ,/I �• ' d _ © C I�I III 1 113 I �� 1 ■ � I ♦ - "?����� I ♦ ' 1 80” BOTTOM OF DEVICE TO F.F. w •— > • 1 TREATMEND j ': •TF�NT 0 t 0 0 % R® 15 % 0 15 � T 3 1 ? m N ,1 © , SO STROBE -- SYSTEM SENSOR SC2W n 107 • '� '. ___ ■ I 80” BOTTOM OF DEVICE TO F.F. _ ct t d IDER 1 % ,� w D: '°"'' � 4. Imo' T° °A ® �' ha PUL STATION - - PSDA N 0 FILE STORAGE V 1 WO IaC� 5T • TION .4163 4 0 - Iii N ~ Q 16 I ; 0 • O © ...1 42 - 48 BOTTOM OF DEVICE TO F.F. o Ol N .. IS Q 1 • O I / .c: at O %. .2 ► an 1 I © % C _, � � Ism SMOKE DETECTOR S , r- - , -- - ----- =- z_,- = -,_ -,s -r� 110 +TM 15 \ � % 15 -- SYSTEM SENSOR 2W8 TT T I mot_ © O © • ff� Z0�1E7' % �� ' L (FRCP) FIRE PANEL -- SILENT KNIGHT 5208 : L iii..•••• ••, •••.•••••• •••••••••,, /,iii ,ii••••• WAV./iiA*WIZZ /ZZ iii/ fi 0 02 ^ ® 2.:71 it m r 18/2 s _ I a § 18/2 = 18 /2 CABLE Z o < / 110 18 9 , ,1 © Oil ` m 14/2 = 14/2 CABLE 0 iIx (.0 Lo ' CORRIDOR 18/ , 0 t 2 I ` o D 0 aDo Y � — — �� 1¢ 4., _ 181 r ? I . I,,J1 a r_. __ i z N Z I . Lull . . • � , �1 • p In In 0 E j% i ` J ,g �� TOP 'a CO ` ∎ 0 0 c In 0 0 110. f% ; . g m 0 inin RECEPTI^•. EOL s ; Q n� 1 I IW 1 W \ / ZONE W ∎ CONDJ T I ; CONDJLT 2 y+ U Q © / 1$ / 1 1021 1 1051 b ? w 18/2 id 4 C.:1 `f ' Z Q to co 1 1 1 P b b . , I__ 3 N •d' 0 N 0 O1 (3) L1 I * o oZo I VI In I I U L a d3 $1aZ 00 co Q LO l0 3M lQ• 0 R '3' Q'-5' (7'-Or , u 0 I- I- N > in M t PROJECT # 17794 -11 ALARM D USE � 06 - 08 08 -11 SUBMITTALS SCALE: 1/8 " =1' -0" FIRE F IRE ALALA RM • "I'LE: 1/8" = 1' -0" DESIGNED BY: LARRY DRAWN BY: • JARED S " 1 E of 1 E T PROJECT # 17794 -11 4 C:C5C2G C ? . F=C'S 7.e., /1 FUNDAMENTALS OF FIRE ALARM SYSTEMS 72.91 FIRE ALARM SYSTEM r� RECORD OF COMPLETION Name of protected property. T (cLL J-` T i.. Q Address: 9',7> S s L -L) 1'l t( U g ( 1! L) F Representative of protected property (name, phone Authority having Jurisdiction: i A �� Address/ telephone number: f '3 / S S (_.) H CL-t ( I'S (Vi) 7" rev ig_cf re_ Organization name /phone Representative name /phone Installer: `L o � 6 !_ . , -. Supplier: •_ ,- , 1--c__L t:1 [_ re4Iarill Service organization: E • LC r.tl.< ri (4 c., v i s Location of record (as- built) drawings: n , , 17 • Location of operation and maintenance manuals: ) �/� Location of test reports: E�? t � _\ /" ` � A contract for test anA Inspection in accordance with NFPA standard(s): Contract no(s): k cJ31j-2S --% Effective Date "7,— ,7247r7( Expiration date: - System Software (a) Operating system (executive software revision level(s): (b) Site-specific software revision date: (c) Revision completed by: (name) (firm) 1. Type(s) of System or Service NFPA 72, Chapter 6 - Local If alarm Is transmitted to location(s) off premises, list where received: NFPA 72, Chapter 8 - Remote Station Telephone numbers of the organization receiving alarm: Alarm Supervisory: Trouble: If alarms are retransmitted to public fire service communication center or others, Indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm Is retransmitted: NFPA 72, Chapter 8 - Proprietary Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communication center or others, Indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm Is retransmitted: ' ' NFPA 72, Chapter 8 - Central Station Prima Contractor: C ii,'— Central Station Location: / 72-2 03 s� r / ._ S C c . ' �� (NFPA 72, of q) 1GURE 4.5.2.1 Record of Completion / • 72 -32 NATIONAL FIRE ALARM CODE Means of transmission of signals from the protected premises to the central station: McCulloh Mutiplex One -way radio Digtal alarm communicator Two-way radio Others Mean of transmission of alarms to the public fire service communications center. (a) (b) System Location: NFPA 72, Chapter 9 - Auxfllary Indicate type of connection: Local energy Shunt Parallel Telephone Location of telephone number for receipt of signals: 2. Record of System Installation (Fill out after installation is complete and wiring is checked for opens, shorts, ground faults, and Improper branching but prior to conducting operational acceptance tests.) This has beened In with the NFPA standards as shown below, was Inspected by `+ `,,, v Ise, /e j 4 on 7.- „9.....7- II ,includes the devices shown in 5 and 6, and has been In service since NFPA 72, Chapters (cneef an am apply) g 1 lg'2 ( a ❑ 5 ❑ 6 7 8 Qg tr10 ❑ 11 NFPA 70, National Electrical Code, Article 760 7r`�� J � ) ,M ___y " , Manufacturer's Instructions Other (specify Signed: Date: —7v-2 n // Organization:.. [ ( e_p vi-A. 11.�,�-t ►.� C G /— 3. Record of System Operation . Documentation In accordance with Inspection Testing Form, Figure 10.6.2.3, is attached All operational features and functions of this system were tested by: " Date: 77 T • and found to be operating properly In accordance with the requirements of: NFPA 72, Chapter (check all that apply) 41 T' p ❑ 5 ❑ 6 ( fi g po ❑ 11 NFPA 70, National Electrical Code, A rticle 760 r /`-'- X Manufacturer's instructions Other (specify) Signed: Organization: (if,. r— LA"A. (t 14 h C' e. A s` • 4. Signaling Line Circuits Quantity and class of signaling Tine circuits connected to system (see NFPA 72 table 6.6.1): Quantity: Style: Class: (NFPA 72, 2 of 4) FIGURE 4.5.2.1 Continued FUNDAMENTALS OF FIRE ALARM SYSTEM 72-33 5. Alarm- Initiating Devices and Circuits Quantity and class of Initiating device circuits (see NFPA 72, Tale 6.5) Quantity: Style: Class: MANUAL (a) Manual stations Noncoded Transmitters Coded Addressable (b) Combination manual fire alarm and guards tour coded stations: AUTOMATIC Coverage: Complete Partial Selective Nonrequtred (a) Smoke Detectors 1 Ion Photo Addressable (b) Duct Detectors Ion Photo Addressable (c) Heat Detectors FT RR FT/RR RC Addressable (d) Sprintder Waterfiow Indicators: Transmitters Noncoded Coded Addressable (e) The alarm verification feature is disabled or enabled . changed from seconds to seconds. (f) Other (fist): 6. Supervisory Signal - Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR (a) Coded stations (b) Noncoded stations (c) Compulsory guards tour system comprised of transmitter stations and Intermediate stations Note: Combination devices are recorded under 5(b), Manual, and 6(a), Guards Tour • SPRINKLER SYSTEM . Check if Provided (a) Valve supervisory stitches ❑ (b) Building temperature points ❑ (c) Site water temperature points ❑ (d) Site water supply level points ❑ Electric Fire Pump: (e) Fire pump per ❑ (f) Fire pump running ❑ (g) Phase reversal ❑ Engine-drIven Fire pump: (h) Selector In auto position ❑ (I) Engine or control panel trouble ❑ (I) Fire pump running ❑ ENGINE -DRIVEN GENERATOR (a) Selector In auto position ❑ (b) Control panel trouble ❑ (c) Transfer switches ❑ (d) Engine running ❑ Other supervisory function(s) (specify): FIGURE 4.6.2.1 Continued (NFPA 72 .3 of 4) 7234 NATIONAL FIRE ALARM CODE 7.Annunciator(s) 4` / Number. L Type: Location: 8. Alarm Notification Appliances and Circuits NFPA 72, Chapter 6 - Emergency Voice/Alarm Service Quantity of volce/atami channels: Single: Multiple: Quantity of speakers installed: Quantity of speaker zones : Quantity of telephones or telephone jacks Included in system: Quantity and the class of notification appliance circuits connected to system (see NFPA 72, Table 6.7): Quantity: Style: Class: Types and quantities of notification appliances Installed: (a) Bells With Visible (b) Spars . With Visible i (c) Horns Visible �/' (d) Chimes With Visible (e) Other j jrro{yes-5 With Visible e>y (1) Visible appliances without audible: 9. System Power Supplies (a) Fire Alarm Control Panel: Nominal Voltage: 2. C Overcurrent protection: Type: Current rating: 2 /L Current rating: Location: (b) Secondary (standby): — Storage Battery: Amur rating: 7 ) r't&� Calculated capacity to drive system , In hours: . Engine- driven generator dedicated to fire alarm system: Location of fuel storage: (c) Emergency system used as backup to primary power supply: . Emergency system described In NFPA 70, Article 700: 10. Comments Frequency of routine tests and inspections, If other than In accordance with the referenced NFPA standard(s); System deviations from the referenced NFPA atandard(s) are: I (signed) fo lotion ntractor /su I (title) (date) 7 (signed) for service co /. = y (title) (date) (sig for central station (fie) �- l/ (date) Upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having Jurisdiction): I (signed) representative of the authority having Jurisdiction (title) (date) FIGURE 4.5.2.1 Continued (NFPA 72, 4 of 4)