Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
y � CITY OF TIGARD MECHANICAL PERMIT i ' - ' COMMUNITY DEVELOPMENT Permit #: MEC2011 -00341 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 07/19/2011 . Parcel: 2S 101 AD03100 Jurisdiction: Tigard Site address: 6950 SW HAMPTON ST 340 Project: Energy Connect Subdivision: Lot: Project Description: Installation of split system for server room. Contractor: YEAR ROUND COMFORT INC Owner: WESTON INVESTMENT CO PMB 432 12042 SE SUNNYSIDE RD 2154 NE BROADWAY CLACKAMAS, OR 97015 PORTLAND, OR 97232 PHONE: 503 - 761 -3900 PHONE: 503 - 284 -2147 FAX: 503 - 761 -3902 FEES Specifics:, Description Date Amount Type of Use: COM Permit Fee 07/19/2011 $170.37 Class of Work: ALT Type of Const: Plan Review 07/19/2011 $42.59 Occupancy Grp: Occupancy Load: 12% State Surcharge - Mechanical 07/19/2011 $20.44 Stories: Info Process /Archiving - Sm Sheet (up to 07/19/2011 $1.00 11x17) Project Valuation: $3,800.00 Fuel Air Handlers Fuel Types: Units < 10000 cfm: Gas Pressure: Units > 10000 cfm: Furnaces Boilers & Compressors Furnaces < 100K BTU: 0 -3 HP: Furnaces >= 100K BTU: 3 -15 HP: Floor Furnaces: 15 -30 HP: Unit Heaters: 30 -50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: 1 Heat Pump: Appliances Vent Fans: Vent Systems: Total $234.40 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports (Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire /Smoke Dampers: . This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to • low the rules adopted by the Oregon Utility No' ion -. er. Tho e rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 4190. You may obtain a copy of the rules or dir= uestions to OU 4 C b, i n 9 50 .232.1987 or 1.800.332.2344. q Iss • d By: , / ei/ Permittee Signature: t c-- r Call 503.639.4175 by 7:00 a.m. for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Applic; hri EIVED FOR OFFICE USE ONLY City of Tigard Receive eBya Permit No.: I ^ 13125 SW Hall Blvd., Tigard, OR 9744 t 19 2011 Plan Review Other Permit: ! Phone: 503.718.2439 Fax: 503.598.19 DateBy: T l GA R D Inspection Line: 503.639 CITY OF TIGARD Date Ready/By: Juris: El See Page 2 for Internet: www.tigard-or.gov BUIL DIVISI Notified/Method: Supplemental Information TYPE OF WORK COMMERCIAL .FEE* SCHEDULE -. USE CHECKLIST Mechanical permit fees* are based onthe value of the work ❑ New construction [Addition /alteration /replacement performed. Indicate the value (rounded to the nearest dollar) of all ❑ Demolition ❑ Other: mechanical materials, equipment, labor, overhead, and profit. Value: $ 3q c:, .`�. CATEGORY, OF CONSTRUCTION RESIDENTIAL EQUIPMENT I SYSTEMS FEES* ❑ 1 - and 2- family dwelling Commercial /industrial ❑ Accessory building For special information use checklist. ❑ Multi- family ❑ Master builder ❑ Other: Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning � <,,, f Job site address: q ' I Mw 5+ c.. l,� (requires site plan showing placement) f 46.75 96 v. "'}'�. � a Furnace 100,000 BTU (ducts/vents) 46.75 City /State /ZIP: (. 6 (� f �� q �Z 3 Furnace 100,000+ BTU (ducts /vents) 54.91 Suite/bldg. /apt. no.: 7 Li b Project name: Heat pump (requires site plan showing placement) 61.06 Cross street/directions to job site: Duct work 23.32 Hydronic hot water system 23.32 Residential boiler (radiator or hydronic) 23.32 Unit heaters (fuel -type, not electric), in -wall, in -duct, suspended, etc. 46.75 Subdivision: Lot no.: Flue /vent for any of above 23.32 Other: 23.32 Tax map /parcel no.: Other fuel appliances: DESCRIPTION OF WORK Water heater 23.32 -+ I Gas fireplace 33.39 LA-et/,.'tn S1, I. L 4-o ' SQ 'etJ- t2C9�. Flue vent for water heater or gas 1 / fireplace 23.32 Log lighter (gas) 23.32 Wood/pellet stove 33.39 Wood fireplace /insert 23.32 ❑ PROPERTY OWNER ❑ TENANT Chimney /liner /flue /vent 23.32 Other: 23.32 Name: Environmental exhaust and ventilation: Address: Range hood/other kitchen equipment 33.39 City /State /ZIP: Clothes dryer exhaust 33.39 Fax: Single -duct exhaust (bathrooms, Phone: ( ) ( ) toilet compartments, utility rooms) 23.32 APPLICANT ❑ CONTACT PERSON Attic /crawlspace fans 23.32 1 Other: 23.32 Business name: V / P LY f ®u_wJ� CO sir 4- Fuel piping: Contact name: �t � ti ( y��r�, $14.15 for first four; $4.03 for each additional 4� ✓ Furnace, etc. Address: I lo t-i l- c-F ( ° " At t.,t c '"� ^'� � r Gas heat pump City /State /ZIP: C 1G- (,lEt� ®k / 61-}01 Wall /suspended/unit heater Phone: (t -) 7 f (- 3 9 XX Fax:: (Co ) Ab i,- 31 OZ., Water heater (� Fireplace E -mail: A.A�r, -4 a_ C@. y— rot,,... I at e J-1- - ( Aries Range CONTRACTOR Barbecue Business name: I \ t t Clothes dryer (gas) Other: Address: i . ( c MECHANICAL PERMIT FEES* City/State /ZIP: f f t Subtotal rr Phone: ( ) Fax ( ) Minimum permit fee ($90.00) / 70.'3 7 Plan review (25% of permit fee) 9A, 5 CCB tic.: ' 7 State surcharge (12% of permit fee) c/ T /.00 Authorized signature: ) J ( O�G� This permit application expires if a permit is not obtained within 180 /.l v_' 1�L days after it has been accepted as complete. Print name: y e`er Date: 7 (q , F ee methodology set by Tri- County Industry nustry Service Board � O 9/09/10 440 -4617T (11 /O 06,,,t" I�� ( " ,/ I:\ BuildingWermits \MEC- PermitApp.doc VCOM/WEB) / 0 (� � 6 a'3L Mechanical Permit Application - City of Tigard Page 2 - Supplemental Information Commercial & Multi- Family Fee Schedule: • Total Valuation: Permit Fee: $0.00 to $500.00 Minimum fee $69.06 $500.01 to $5,000.00 $69.06 for the first $500.00 and $3.07 for each additional $100.00 or fraction thereof, to and including $5,000.00. $5,000.01 to $10,000.00 $207.21 for the first $5,000.00 and $2.81 for each additional $100.00 or fraction thereof, to and including $10,000.00. $10,000.01 to $50,000.00 $347.71 for the first $10,000.00 and $2.54 for each additional $100.00 or fraction thereof, to and including $50,000.00. $50,000.01 to $100,000.00 $1,363.71 for the first $50,000.00 and $2.49 for each additional $100.00 or fraction thereof, to and including $100,000.00. $100,000.01 and up $2,608.71 for the first $100,000.00 and $2.92 for each additional $100.00 or fraction thereof. Note: All new commercial buildings require 2 sets of plans. 1:\ Buil ding \Permits\MEC- PermitApp.doc 09/09/10 2 MITSUBISHI T MI ore SUM HVAC Advanced Products Division Split Zoning A/C and Heat Pumps SlJBMITTAI DATA A Y Gel8NA 8 All U1( GEEEl8NA � s,u o erurl vv4k.rutON oAI cpmtpmarfl 9sYSfn!s :' Job Name: Location: Date: Purchaser: Engineer: Submitted to: For El Reference Approval ❑Construction Unit Designation: Schedule No.: GENERAL FEATURES .. • Wall- mounted indoor unit • Standard Hybrid Catechin Prefilter is included with indoor unit may • Quiet operations " j , • Choice of fan speeds: Quiet, Low, Medium, High, and Super High; t, w Auto fan speed control also included Indoor Unit: MSY GE18NA ., ' , ; • Wireless remote controller is included; PAR -21 MAAwired k a \ .j °° remote controller can be installed as an optio " y : • Indoor unit powered from outdoor unit using A- Control ,„' ' r • Auto restart following a power outage ��� • Limited warranty: five years on parts and defects and seven years Wireless Remote , Outdoor Unit: MUY- GE18NA on the compressor Controller i °x Indoor Unit �+ , � �. r �, 2 kcop- OPTIONAL ACCESSORIES MCA � °� •` " �' A Outdoor Unit Fan Motor 0 76 F.L.A. • Drain Socket Assembly (MAC -811 DS) Airflow (Quiet - Lo - Med - Hi - Super Hi) Cooling 230 - 275 - 339 - 420 - 533 Dry CFM Indoor Unit 194 - 240 - 304 - 385 - 498 Wet CFM • M -NET Control Adapter (MAC 399lF) Sound Pressure Level (Quiet - Lo - Med - Hi - Super Hi) • MA Contact Terminal Interface (MAC - 397IF) 1' • • Wired Remote Controller (PAR -21 MAA; requires MAC - 397IF) Cooling 28 33 38 44 - 49 dB(A) • Condensate Pump (230V; SI3100 -230) 1 • Anti - allergy Enzyme Filter (Two pieces per set; MAC- 408FT -E) DIMENSIONS UNIT INCHES / MM W 31 -7/16 / 799 D 9 -1/8 / 232 Cooling* H _11 / 295 Rated Capacity 17,200 Btu /h Weight 22 lbs. / 10 kg Minimum Capacity 3,700 Btu /h External Finish Munsell No. 1.0Y 9.2 / 0.2 SEER 19.2 Btu /h/W Field Drainpipe Size O.D. 5/8" / 15.88 mm Total Input 1 640 W Remote Controller Wireless • Rating Conditions (Cooing) - Indoor 80 °F (27°C) DB, 67 °F (19 °C) WB , Outdoor. 95 °F red Remote Controller PAR -21 MAA; (35°C) DB, 75 °F (24 °C) WB. (Optional Wi see Data Submittal Sheet) Electrical Requirements Outdoor Unit Power Supply 208 / 230V, 1- Phase, 60 Hz Comp ressor DC Inverter- driven Twin Rota Breaker Size 15 A MCA 14 A Voltage Fan Motor 0 93 F.L.A. Indoor - Outdoor S1 - S2 AC 208 / 230V Sound Pressure Level Indoor - Outdoor S2 -S3 DC 12 -24V Cooling 54 dB(A) Indoor - Remote Controller Wireless • DIMENSIONS INCHES / MM OPERATING RANGE W 33 -1/16 / 840 Indoor Intake Air Temp. Outdoor Intake Air Temp. D 13 / 330 90`F (32"C) DB, H 33 -7/16 / 849 Maximum 73 °F (23 °C) WB 115°F (46 °C) DB Cooling Minimum 67 °F (19 °C) DB, 14°F (-10°C) DB Weight 119 lbs. / 54 kg 57 °F (14 °C) WB External Finish Munsell No. 3Y 7.8 / 1.1 Refrigerant Type R410A � Refrigerant Pipe Size O.D. i r CI OF IGAIRD Liquid Side 1/4 " /635mm c, -- Max. Refrigerant Pipe Length 100 ft. / 30 m Approved ................ "�.' —[ Max. Refrigerant Pipe Height Difference 50 ft. / 15 m Conditionally Approved [ Connection Method Flared See Letter to: Follow [ ] Attached �- '" ( � N t R Permit N . i e r . __ ZC --W OFFICE COPY ,. _ , R Ad. ess: . d ._ ..� r.Cih By: Date: � A ' IMENS DI N�MSI( GE18NA 8� MUY= GI 8 ..d. _ .5 �, .r �. �. '�. --.. �t w� ® .. ...� :1wti�". � i .:: e., RS N a. r .. . . ••% MSY- GE18NA Unit: inch t 7/16x1 Oblon. hole 7/16.13/16Oblon. hole r 8 -718 _ 8-7/8 _ 3 -1/8 m Installation plate 3-1/8,4 I ^� 31 -7/16 1 ir -[-- -- ---i -- -- —i— - . 30 -15/16 1 _/4 I 'r N I m ro rn �I� .-- � - - ■1I1 �w i , - I s ___i,,,___U _ 6 -1/8 6 -1/8 - - -.. Il, - -- . � 2-3/8 13-5/16 13-9/16 2-1/8 9 -1/8 Air in Wall hole o2 -9/16 3/16 Indoor unit \/— - I Installation .late Pi.in. m m livii u� M a m TO 1 -3/4 < ; 1 1 -5/8 N m c7, 1- 15/16 _1_ _ 24 -3/8 5 -1/8 \ Drain hose 4 -3/8 2- 5/161 I _ I I 3/4 Air out I L m Ill Insulation 01 - 3/8 0.D - M■ Mal F.. Liquid line 01/4 19 - 11/16 (Flared connection o1 /4) I _ a Gas line 03/8 16 - 15/16 III ' I 1 " 2 -3/16 1 -15/16 1 "'111 I (Flared connection 0/8 (GE06109112NA), 01/2 (GE15NSNA)) Drain hose Insulation o1 -1/8 0.D Connected part 05/8 O.D MUY- GE18NA Open as a rule 1 0 20 inch or more if the front and both REQUIRED SPACE sides are open 20 -9/32 4 inch or more/ f Drain 3 holes 8 inch or more if (e1 -5/16) 11 -25/32 1 -9/16 there are obstacles Air i to both sides E NE - 0 I Ai i n _ r, R rn. m dre �� � ®11 O, 1 �� l Air = ut 4 -3/8 . 13/16 slot I / rn. or 19 -11/16 -> A more 3 - 3/16 Open as a rule \��fj' . 33 - 1/16 20 inch or more if the back, 4 -25/32 both sides and top are open . d - r 9 . _ I ..! MN o d itt — , .n \ \\ j �t N 1 Liquid :1 /4(tlared) } e -Gas :1 /2(flared) — ' —M_ 8 -11/32 MITSUBISHI If ' ,, ELECTRIC EN :.% GEREIFfED PAar�1R HVAC Advanced Products Division n w w " c *K,.m 3400 Lawrenceville Suwanee Rd umtWismauAC wsnsr�roarv2161240 , Suwanee, GA 30024 ,; a , • �, . • . , Tele: 678- 376 -2900 • Fax: 800 - 889 -9904 4 /STEQ ® Toll Free: 800- 433 -4822 ( #3) www.mehvac.com C SD - MSY- GE18NA & MUY- GE18NA- 201003 © MITSUBISHI ELECTRIC / HVAC 2010 Specifications are subject to change without notice.