Loading...
Permit CITY OF TIGARD MECHANICAL PERMIT ;: COMMUNITY DEVELOPMENT Permit #: MEC2011 -00297 x " ""� 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 07/12/2011 �� Parcel: 25101 CB00500 Jurisdiction: Tigard Site address: 12670 SW HALL BLVD, BLDG# 2 Project: Apex Industries Subdivision: BEVELAND CORPORATE CENTER Lot: Project Description: (2) RTU's. Contractor: VANCOUVER ROOFING & SHEET METAL CO Owner: TCTPI LLC P.O. BOX 8951 1205 NW 25TH AVE VANCOUVER, WA 98668 PORTLAND, OR 97210 PHONE: 360 - 695 -9263 PHONE: FAX: 360 - 213 -0606 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 07/12/2011 $733.79 Class of Work: ALT Type of Const: VB Plan Review 07/12/2011 $183.45 Occupancy Grp: F -1 Occupancy Load: 12% State Surcharge - Mechanical 07/12/2011 $88.05 Stories: 1 Info Process /Archiving - Lg Sheet (over 07/12/2011 $2.00 11x17) Project Valuation: $25,167.00 Info Process /Archiving - Sm Sheet (up to 07/12/2011 $12.00 11x17) Fuel Air Handlers Fuel Types: Units < 10000 cfm: Gas Pressure: Units > 10000 cfm: Furnaces Boilers & Compressors Furnaces < 100K BTU: 0 -3 HP: Furnaces >= 100K BTU: 3 -15 HP: Floor Furnaces: 15 -30 HP: Unit Heaters: 30 -50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $1,019.29 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: • Required Items and Reports (Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire /Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: • • n'ttee_Signature: —";� %. Gam—' glib _____ _ Call 50 4175 by 7:00 a.m. for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Application FOR OFFICE USE ONLY City of Tigard Re ceived l / Permit No.. Date/By: II a 13125 SW Hall Blvd., Tigard, O'. '^+ O (1., Plan Revie r Mr 1� 1 G` (/` � rt1 7 Phone: 503.718.2439 Fax: 50 "$: '� `',.` V �o Date/By: I Other Permit: Inspection Line: 503.639.4175 \ V T I G A RD `V� ' C\G iO Date Ready/By: Juris: ® See Page 2 for Internet: www.tigard- or.gov , O � \ Notified/Method: 7 � / I' -Tc Supplemental Information V iJ0 t . 411111111 o �y (y TYPE OF WO Q COM t`'CIAL FEE* SCHEDULE — USE. CHECKLIST tiN,�� Mechanical permit fees* are based on the value of the work ❑ New construction ® Addition/alteratio eplacement performed. Indicate the value (rounded to the nearest dollar) of all ❑ Demolition ❑ Other: mechanical materials, equipment, labor, overhead, and profit. Value: $ $25,167.00 CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT / SYSTEMS FEES* ❑ 1- and 2- family dwelling ® Commercial /industrial ❑ Accessory building For special information use checklist ❑ Multi- family ❑ Master builder ❑ Other: Description I Qty. I Ea. I Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning Job site address: 12670 SW Hall Blvd (requires site plan showing placement) 46.75 Furnace 100,000 BTU (ducts/vents) 46.75 City/ State/ZIP: Tigard Oregon 97223 Furnace 100,000+ BTU (ducts/vents) 54.91 Suite/bldg. /apt. no.: 0. Project name: Apex Industries Heat pump (requires site plan showing placement) 61.06 Cross street/directions to job site: Duct work 23.32 Hydronic hot water system 23.32 Residential boiler (radiator or hydronic) 23.32 Unit heaters (fuel -type, not electric), in -wall, in -duct, suspended, etc. 46.75 Subdivision: I Lot no.: Flue /vent for any of above 23.32 Other: 23.32 Tax map /parcel no.: Other fuel appliances: DESCRIPTION OF WORK Water heater 23.32 Install two new roof top air conditioning units Gas fireplace 33.39 Flue Vent for water heater or gas fireplace 23.32 Log lighter (gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 ❑ PROPERTY OWNER I ® TENANT Chimney/liner /flue /vent 23.32 Other: 23.32 Name: Apex Industries Environmental exhaust and ventilation: Address: 12670 SW Hall Blvd Range hood/other kitchen equipment 33.39 City /State/ZIP: Tigard Oregon Clothes dryer exhaust 33.39 Single -duct exhaust (bathrooms, Phone: (503)235 -8324 Fax: (503)352 -3686 toilet compartments, utility rooms) 23.32 ❑ APPLICANT ❑ CONTACT PERSON Attic /crawlspace fans 23.32 Business name: Apex Industries Other: 23.32 Fuel piping: Contact name: Ed Arthur $14.15 for first four; $4.03 for each additional Address: same Furnace, etc. Gas heat pump City /State /ZIP: same Wall/suspended /unit heater Phone: (503) 960 -6751 Fax: : (503 -) 352 -3686 Water heater E -mail: Fireplace Range CONTRACTOR Barbecue Business name: Vancouver Roofing and Sheetmetal Clothes dryer (gas) Other: Address: 217 X Street (PO Box 8951) MECHANICAL PERMIT FEES* City/State/ZIP: Vancouver ,WA 98661 ( Vancouver WA 98668) Subtotal 1203 Phone: (360) 695 -9263 Fax: (360) 213 -0606 Minimum permit fee ($90.00) Plan review (25% of permit fee) 301 CCB lie.: 6208 State surcharge (12% of permit fee) 36 ��� TOTAL PERMIT FEE 1540 Authorized signa id Thi permit application expires if a permit is not obtained within 180 j�1 days after it has been accepted as complete. Print name: Gary Da 6/27/1 * Fee methodology set by Tri- County Building Industry Service Board I:\Building\Permits\MEC- PermitApp.doc 09/09 /10 440 -4617T (1l /02/COM/WEB) July 5, 2011 RE: MECHANICAL TI Project Information Building Permit: MEC2011 -00297 Construction Type: 5B Tenant Name: Apex Industries Occupancy Type: F -1 Address: 12670 SW Hall Blvd Occupant Load: NA Area: NA Stories: 1 The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2010 edition; and the State of Oregon Fire Code (OFC) 2010 edition. The following corrections need to be submitted for review prior to issuing of the permit 1) Provide structural drawings showing all connectors, design and calculations for seismic connections of RTU's to curb and curb to roof . 2) Show design of roof framing for support of vertical loads from RTU's. 3) Provide cut sheets showing weights of units to be installed. When responding, provide an itemized letter stating in what way each numbered issue has been addressed in the revision. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Dan Nelson, Senior Plans Examiner (503) 718 -2436 dann @tigard- or.gov RECEIVED JUN 2.8 2011 CITY OF TIGARD • ID 411114 / BUILDING DIVISION I Date 6!28/2011 N I Number of pages including cover sheet 3 We are a WBE Contractor ( WBE # 3665 ) To: City of Tigard FROM: Gary Bechtoldt Ann. Dan Vancouver Roofing and Sheet Metal P.O. Box 8951 (98668) Re: Apex Industries 217 'X" Street Permit Application # Vancouver WA 98661 MEC2011 -00297 e-mail gbechtoldt @vrsm.com Phone 503 - 718 -2439 Phone (360) 695 -9263 Fax Phone 503 - 598 -1960 (503) 285 -8027 Fax Phone (503) 285 -9901 I REMARKS: ❑ Urgent ❑ For your review ❑ For distribution ❑ Please Comment Dan, Here is the attachment detail you requested for the roof units and also a submittal sheet; both units are the same. Let me know if you need anything else. Please contact me on my cell @ 360- 901 -7673 when the permit is ready to pick up and also advise the correct fee amount. Thank, ou, ary Bechtoldt 6'd 609Z hags 6ui ;ooyaannoouen dgj7:Z6 gZunr Jun 28 11 12:49p Vancouver Roofing & Sheet 360- 213 -2509 p.3 Ed Arthur - Rooftop Units May 13, 2011 • Unit Dimensions - 3 -10 Ton R-410A PKGD Unitary Cooling Rooftop Item: Al, A2 Qty: 2 Tag(s): RTU -1, RTU -2 TOP PANEL EVAPORATOR SECTkON ACCESS PANEL CONDENSER FAN CONDENSATE DRAIN (ALT) 314 " -14 NPT DIA. HOLE =¢iQ11�� � ONDENSER COIL 4 1/4:i ! \ ` ti NIT CONTROL WIRE 7/8" DIA. HOLE 27 518 01101) 47 718" \ -. 1 eilo � ERV ICE GAUGE PORT ACCESS 1319' CIA. MOLE 2' ELECTRICAL CONNECTION NIT POWER WIRE (SINGLE POINT POWER WHEN HEAT INSTALLED) \ ''—CONTROL AND COMPRESSOR ACCESS PANEL THROUGH THE BASE CONDENSATE 1.. 275/8" 2.T -THE -BASE O NNEC TI O N ISNOT L DIMENSION WITH DNDARDON ALL UNITS. ' — 41/r 2 INSTALLER DOCUMENTS t EFORE INSTALLATION s i /'� r-- --7-1- r- - - - - -1 / �` ` i 1� ` 0 � � �� SUPPLY ' RETURN 32 I8 f L - - - - _I i ---- - _I - 4 I .. i I I • tr 17 12' 1 9 7/8" 17112" —°t I 3 518" PLAN VIEW UNIT DIMENSION DRAWING III —7 HORIZONTAL RETURN 32114' 48 7 AiR FLOW SUPPLY 23718' I 1 241/2" ' '---r..= . 4 314" 1 P 9 55/8 1 e� L.-!I .-� / i 4 1/4" - 19 114" • 93/T - 16 3/4" - 3 7/8" ' I 5 5/13" - - i 88 5/8" - - 7 sta. CONDENSATE PACKAGED COOLING - 53 1/4" DIMENSION DRAWING FLD = Furnished by Iran U.S. lac. / installed by Equipment Proposal Page 3 of 12 Others .1