Permit CITY OF TIGARD BUILDING PERMIT
•
f COMMUNITY DEVELOPMENT Permit #: BUP2011 00136
13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 07/07/2011
'TIGARD Parcel: 2S109DA14000
Jurisdiction: TIGARD
Site address: 12677 SW MOUNT VISTA CT
Project: ARLINGTON HEIGHTS NO. 3, LOT 59 Subdivision: ARLINGTON HEIGHTS NO. 3 Lot: 59
Project Description: Installation of solar photovoltaic system.
Contractor: LIVELIGHT ENERGY LLC Owner: STONE BRIDGE HOMES
1750 SW 187TH AVE 16869 SW 65TH AVE #505
BEAVERTON, OR 97006 LAKE OSWEGO, OR 97035
PHONE: 503 -690 -4402 PHONE: 503 - 387 -7577
FAX: 503 - 690 -4399
FEES
Specifics:
Description Date Amount
Type of Use: SF Solar Photovoltaic System 06/28/2011 $180.00
Class of Work: ALT 12% State Surcharge - Building 06/28/2011 $21.60
Dwelling Units: 0 12% State Surcharge - Building 07/07/2011 $21.60
Stories: 0 Height: 0 ft Investigation Fee (Equals Permit Fee) 07/07/2011 $180.00
Bedrooms: 0 Bathrooms: 0 Info Process /Archiving - Sm Sheet (up to 07/07/2011 $11.50
Value: $0 11x17)
Floor Areas:
Total Area: 0
Accessory Struct: 0
Basement: 0
Carport: 0
Covered Porch: 0
Deck: 0
Garage: 0
Mezzanine: 0
Total $414.70
Required: Required Items and Reports (Conditions)
Fire Sprinkler: Parapet:
Fire Alarm: Protected Corridors:
Smoke Detectors: Manual Pull Stations:
Accessible Parking: 0
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will
be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180
days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
952- 001 -0010 through OAR 952 - 001 -0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344.
17111mui, pppp
Issued B /:_opy AMP Permittee Signature:
�11r� .• 39.4175 by 7 :00 a.m. for the next available inspection d '
This permit card sffall e kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
, i
Building Permit Application
r
Residential FOR OFFICE USE ONLY
_ .. City of Tigard R ECEIVED Date /By: ail � i .� a�i 4% a 13125 SW Hall Blvd., Ti
� •� Pen nit No.:
- Tigard, OR 97223
g Plan Review Other Permit:
P hone: 503.718.2439 Fax: 503.598.1960 JUN 2 8 2011 Date /By: 1' ' I' ��, mss ®10// OOQ.27
TIGARD Inspection Line: 503.639 Date Read /By: / hurls: H See Page 2 for
Internet: www.tigard - or.gov CITY OF TIGARD Notif .d /Method: 6 Supplemental Information
CITY 1 v ce i V
-- -- - - i s v ._ I . . • k_ "/ AV - - -- -
TYPE OF WORK REQUIRE t I ATA: 1- AND 2- FAMILY DWELLING
® New construction ❑ Demolition Permit fees* are based on the value of the work performed.
Indicate the value (rounded to the nearest dollar) of all
❑ Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
® 1- and 2- family dwelling ❑ Commercial /industrial Valuation: $2000
❑ Accessory building ID M ulti - family Number of bedrooms:
❑ Master builder ❑ Other: Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address: 12677 Mt. Vista Ct. New dwelling area: square feet
City/State /ZIP: Tigard, OR 97224 Garage /carport area: square feet
Suite/bldg. /apt. no.: Project name: 12677 Mt. Vista Ct. Covered porch area: square feet
Cross street /directions to job site: Deck area: square feet
Other structure area: square feet
REQUIRED DATA: COMMERCIAL USE.CHECKLIST ,
Subdivision: Arlington Heights I Lot no.: 59 Permit fees* are based on the value of the work performed.
Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all
equipment, materials, labor, overhead, and the profit for the
- DESCRIPTION OF WORK work indicated on this application.
Racking and installation of a solar photovoltaic system. Valuation: $
Existing building area: square feet
New building area: square feet
®. PROPERTY OWNER ❑ TENANT Number of stories:
Name: Stonebridge Homes Type of construction:
Address: 16869 SW 65' Ave Suite 505 Occupancy groups:
City/State /ZIP: Lake Oswego, OR 97035 Existing:
Phone: ( ) Fax: ( ) New:
►1 APPLICANT ® CONTACT PERSON BUILDING PERMIT FEES*
Business name: LiveLight Energy, LLC (Please refer to fee. schedule)'
Structural plan review fee (or deposit):
Contact name: Molly Stradley
FLS plan review fee (if applicable):
Address: 1815 NW 169th place, Ste 4020
Total fees due upon application:
City/State /ZIP: Beaverton, OR 97006
Phone: (503) 682 - 2168 Fax: : (503) 690 - 4399 Amount received:
E - mail: molly @livelightenergy.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
Commercial and residential prescriptive installation of
CONTRACTOR roof -top mounted PhotoVoltaic Solar Panel System.
Business name: LiveLight Energy, LLC Submit two (2) sets of roof plan with connection details
and fire department access, along with the 2010 Oregon
Address: 1815 NW 169' place, Ste 4020 Solar Installation Specialty Code checklist.
City/State /ZIP: Beaverton, OR 97006 Permit Fee (includes p lan review $180.00
and administrative fees):
Phone: (503) 682 - 2168 Fax: (503) 690 - 4399
State surcharge (12% of permit fee): $21.60
CCB lic.: 187491
Total fee due upon application: $201.60
Authorized signature: ' 7' OF 1 •■ ! I. . This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
Print name: Molly Stradley
• Date: 6 - 27 - 2011 * Fee methodology set by Tri- County Building Industry
Service Board.
1: \Building\Permits\BUP - RESPermitApp.doc 02/24/2011 440- 4613T(I 1 /02 /COM /WEB)
City of Tigard
'' Building Division REC
13125 SW Hall Blvd, Tigard, OR 97223
Phone: 503.718.2439 Fax: 503.598.1960 JUN 2 8 2011
T I G A R D Inspection Line: 503.639.4175 CITY OF TIGARD
www.tigard- or.gov BUILDING DIVISION
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof - Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 12677 Mt. Vista Ct.
City: Tigard Zip: 97224
Owner's Name: Stonebridge Homes Date: 6 -24 -2011
Contractor's Name: LiveLight Engergy CCB #: 187491
Design Parameters of the Property /Structure
If "Yes ", does not
Flood Hazard Is the installatio Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? ® N OSSC or ORSC for
design requirements.
Wind Exposure Is the wind exposure ® Yes If "Yes ", qualifies for
"C" or less? No the prescriptive path.
Installations on detached Is the Ground Snow
single /two - family Load 70 psf or less?
dwelling/single /two- If "Yes ", qualifies for
family townhomes ® Yes the prescriptive path.
and /or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
If "Yes ", qualifies for
structures other than ❑ Yes the prescriptive path.
above
❑ No
1
1 JBui lding/Fonns /Photo V oltaic- Checklist.docx
Is the construction
material wood and does Yes
Type of If "Yes ", qualifies for
the construction qualify No the path.
• Construction as "conventional light ❑ prescriptive p p
frame" construction?
Is the spacing 24 inches
or less?
Pre - engineered trusses. ® Yes If "Yes ", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. ❑ If "Yes ", qualifies for
Yes the prescriptive path.
❑ No
Is the combined weight ® Yes
of the PV modules and If "Yes ", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance Yes
with Section 305.4(3) of If "Yes ", qualifies for
the 2010 Oregon Solar ❑ No the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle /shake checked, qualifies for
Max. two layers the prescriptive path.
® of composition
shingle.
Is the roof mounted ® Yes
Connections of solar assembly
the solar assembly connected to roof If "Yes ", qualifies for
framing or blockin ❑ No the prescriptive path.
to the roof g g
directly?
2
I: /Building /Fonns /Photo V olta is -Ch ecklist.docx
❑ Yes If "Yes ", qualifies for
Is the gauge 26 or less? ❑
No the prescriptive path.
115 lbs for 60 inch
spacing or less?
❑ If "Yes ", qualifies for
Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If "Yes ", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inche Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal anels If the width of the panel
P Width of roofing is less than 18 inches,
panels? 18 inches or less
inches qualifies for the
prescriptive path.
Minimum #10 at 24
inches o /c?
Size and spacing of If "Yes ", qualifies for
fastener? El Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. 'A" thickness, ❑ Yes
decking connected to If "Yes ", qualifies for
framing members ❑ No the prescriptive path.
w /min. 8d nails @
6 "/12" o /c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If "Yes ", qualifies for
solar modules module to the roof ® Yes the prescriptive path.
surface. ❑ No
3
1:/ Building /Forms /Photo Voltaic- Checklist.docx
a
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: SolarWorld
Model Number: SW250
Listing Agency: UL
4
I: /Building /Forms /Photo V oltaic- Checkl i st.docx