Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
yarit RESIDENTIAL SOLAR MOUNTING SYSTEM The Canopy mounting system optimizes strength, waterproofing, performance and aesthetics by structurally attaching solar panels to composition shingle and wood shake roofs. 5052 alloy coated with a 2 -step anodizing offers superb structural and fatigue strength and corrosion resistance even in maritime environments. Bracket -style attachment allows for shingle flashings to completely cover penetrations, providing excellent long -term waterproofing. • Precision engineered bracket geometry provides stiffest uplift resistance of any mounting bracket. Rated to 470 lbs. • 5052 alloy offers excellent structural and fatigue strength. • All -metal Galvalume® flashing completely covers penetration, providing better long term leak protection than neoprene cone flashings. • Galvalume sheet steel is a 55% Al -Zn coated sheet steel providing ✓_� superior corrosion resistance over conventional galvanized steel. A rgGARD Approved .. .Q L:"� Conditionally Approved Of Shingle Flashing locks in ,c d •.v {mpofira [ ] ff (2) 5 /16 " la g bolt A X 11 p Ad. • • it ON" I +� (2) 5 /16 flat washer r By: _ ils� Date: EMI • Precision engineered canopy mounting bracket `1 t OFFICE COPY %!!! SolarCit 888 -SOL -CITY 1 888 - 765 -2489 I WWW.SOLARCITY.COM APPROVED INSTALLATION METHOD • Brackets are to be mounted no further than 8' apart. • Rafters must be located. Pilot holes must be drilled into NUMBER OF EMBEDMENT CASE PTE LAG OF LAGS the center of rafters. (INCHES) • Shingle course immediately above penetration shall be cut 1 29 1 I 2.5 using provided template to accommodate flashing. 111 34 1 3 • Local wind conditions, exposure, roof angle, and position 43 2 2.5 of array on roof will determine design wind pressure. 4 50 2 3 Standard installation of Canopy applies when design wind This chart assumes 14 sq. ft. or fewer per panel pressures are found to be 29 psf or lower and requires one and minimum 1.5 penetrations per panel. * psf values to be calculated according to ASCE 7 -05. 21/2-inch lag bolt in the primary position. For all other cases, see chart to right. • Flashing is to be inserted under course of shingles above penetration and pressed down over root until it snaps into place. • Rail is attached with rail locking clamp or standard stainless fasteners. 0 Flashing • ri Lags and washers • Bracket 4441411111111%1141411111114 1%1141141P it Bracket installed • Flashing installed . - s Rail installed 8'0C Max • Roof rafter "'_ -4111111111.1111j111°7. • Rail ',44 J@Era ' 11 lr -n-dbla S T R U C T U R A L E N G I N E E R STRUCTURAL CALCULATIONS FOR THE S0LARCITY ROOF MOUNTING C LIP stef v lir .16 P iVil No. S• m 4 Exp. 3/31/11 at \* * \d-41/, '; w- ` = OF MAC " FESSro ED PR Ore 4O A H. 0 < e.t. F cAy. 'e c � 5 � �, G ► N EF � " c , � s F � ► ' ► * co • ' �� '9 /� �� � , Q ' 48707 0 �a 84067PE 9 o •05 qy. ' ►, /. ` m nft.;..- s' I. G W. C..:, • . I , w. G :4— r Q �J. Cam. t t r REGON N 0. C67059 JOSEP H. o / 0 0 PE-44104 * Exp. 9 -30 -10 �e s/ i ,� t;% H y 2 Z °` GQ �`'� o ' ' _ arNA 0. 7 9 7 ned. r' HAR�`9 ♦ r \\,.............. ' ONA1 OF CA1-� CA1N RENEWS' DEC. 31, 2011 SV18/10 2816 HILLEGASS AVENUE; BERKELEY, CA 94705; PHONE: (510) 666 -0700, FAX: (510) 666 -0707 738 SolarCity Roof Mountng Clip.doc 8.00" CLIP MADE WITH 2.42" +.50" 1.34" 0.50" 3.74" 0.64" Y 5052 -1132 ALUMINUM; Fcy = 21 KSI - - - • RAIL — 4 — .- CLAMP �-1 ( s N - M N o ' UNIRAC �- MOUNTING RAIL P.•, SEE TABLE -- - • it') 4.040 1.42" C 9 O r _ . 00 d 1 �� 1 Q l � � �' of J co a o 31e'ca LAG SCREWS 2.36" d o Co 0 2 ®q. OF (E) 2x (71"),I.... W RAFTER SEE TABLE 0 i r 5 Fz 1 + *......� z' LAG A - --'*, �'o r LAG B s y i U�' LAGS A &B A &B AONLY AONLY 4 �F�cAr F °.y � p p .o � >�p�l �1 . �: EMBED 3" 2X" 3" 2) " to 48707 4 b o i 'TCy p 470# 400# 315# 270# 14, ... PE - 44104 41 ■ . CAIN l H . '� / AL '' YPICAL ROOF MOUNTING CLIP -1' -1 4, ' '•- s. OV Z oNA 0• �1 '` �... ` 5 /Ib /i0 F4 7 4` en ( PROF . `� i • i t '"c• 8 Q ' o. 5 -3385 /. ' ,,,.ca.:...._ STRUCTURAL ENGINEER * Exp.3 /31/11 * • , OREGON 2816 HILLEGASS AVE.; BERKELEY, CA 94705 �. pt,'(/41- �o Z PHONE. (510) 666 -0700; FAX: (510) 666 -0707 J}q� APP ; , 12, 2� GQ' HAR 1 1 6�!!, f . . 'SolarCity RENEWS: DEC. 31, 2011 O /+i CLIP JOB NO. 738 ( J o �NJ I j(a1 N M LAGS & NG QATE: 4 -21 -8 STRUCTURAL ENGINEER BY: JDH SHEET: Gt+k- LAGS e 47o # CD CO 2(2 - N ' ` rvWl A r A Go/,IJ.I. -TOIZ Gic 1.4u L AC 3.3541" I 4.9858" �RAIRAC 2- g�'' ( j r\( 7..., Lf °/ " E 4.0674" => Tait u Z K I• G. x *43 = I ,; q BOLT r MI ! GROUP CbfecK. LiEpbrQ,JLit* a 440oD 1+ .......iil , P _ 1 0 '5o .1,(7- 5 i GNEck P e 2L " $cD 1 __._________. ______ _ _. - -- 2.2361" 1T 1 21( — Zxl•L it 290 e(�+ )-11290 =� P� - 4c -- - ___,[ 4•x,1 4.07 .. _ G ft Gi < r G I LAC/ 7 3 E. i a-D - tail _ tiCo 4-e• e) = T4-9 I '� 1f - 4 , ` ?? -149 - fi = 315 G IL z.97 rG� ,I, .2 t r "j, ,,_ . C *6tk Q IL C.. wi 7,. egi6e D Ai Q Y = 14 A 4A.," Co 4S ail 7¢3 -- .4 SoIarCit 2816 HILLEGASS AVE. BERKELEY, CA. 94705; PH: (510) 666 -0700, FAX: (510) 666 -0707; JdhallamOtransbay.net _ E.NO B s G IM AQ vGi- St ' o`gy a. P DATE: I 3� -_ STRUCTURAL ENGINEER BY: JD SHEET: o,Ias' it EL h to a A d z z 1 e,643 e) iv; 067Z. 0.ceix, a,cYLlo D w3 0. 01.9 . 11 41 r 2 -- — 0. IL); b, UI I, U. LZy6 3 - v . oot.) <1 3 (3)- 3 0,125 f v('z Q L .l.S 0 , 7,' o , vw7 0,6x.43 tb . aa2. _b.Ld� _ 6 !D 331 6.0305 TT S 5 �x o.05� - .�� o1 Z' V ? - . 6.1 1_.. _ 71[(.2=,) (.izs)" 5 r R _ - -- - ---- - 4).01 5057.- b>:3 2- =. b - 31 1 Fti = 23 ) t = z1 i E 7 -1 0 . E . 25lo 15 61. =1.3) Z14 0.' - 3 Y>,I -� •. 0.2 717. 161-- 3. 4,2 f1 = I -9s 1 1\ - 1.651 n,, = 0.- 14L 3,4,- 17 =) b < 5f..c - 113x2.1 = 15,4'7 5, t • 3, s 6.2 I.3 X Z- YNx (o +jt,t5- t ) b 6, Oco1 _ _ 1N1 . < ! , 43 k- a..= 4. v7 => f t -' 5 1,3 = 470 2 1 :b b .' is Solar Ci . 2816 HILLEGASS AVE. BERKELEY. CA. 94705; PH:(510) 666 -0700, FAX:(510) 666 -0707; IdhallomOtransbay.net Q,ela®@ [ 3 MENEE S T R U C T U R A L E N G I N E E R STRUCTURAL CALCULATIONS FOR THE S0LARCITY' s ROOF MOUNTING CLIP Qi ksf ES , , � tic i Z � w No. S•3385 m a Exp. 3/31/11 4' �* * � yy, E pPROF ��FESSI�/�� ote sslona�F nai 1` rd ` L � p Q �pN H. 0 4/4, 4 6i e� 5 � ,GA / °� .� o� ° H� �� ��5 � 4 48707 d c l 84067PE 9 �. •05 qy.� ',, CC N0. C67059 I / OREGON V J SEPH H. � p � ., PE-44104 S CMN t ' �qN, 2 GQ' 4� * Exp. 9 -30 -10 * e s 1 �$ � 12 , • �ONA1 � ,. 7 nod r ' HAFT 9 I I't I = `r >q CAM- 4��� 9 �ONA. U �� '``�,...... S�ss /i �4F CA`` CA ES 9r�2° RENEWS: DEC. 31, 2011 S /t8 /to 2816 HILLEGASS AVENUE; BERKELEY, CA 94705, PHONE: (510) 666-0700, FAX: (510) 666 -0707 738 SolarCity Roof Mountng Clip.doc LABELS ELECTRICAL NOTES GENERAL NOTES LEGEND ABBREVIATIONS PHOTOVOtSMC POINT Or INTERCONNECTION ' WARNING!EECTRICSHOCK HAwm! 1• 1. WHERE ALL TERMINALS OF THE 1. THIS SYSTEM IS GRID— INTERTIED VIA A UL— LISTED �• " - — O (E) UTILITY METER A AMPERE . ( ♦) .. „.= °"”" ; DISCONNECTING MEANS MAY BE ENERGIZED POWER — CONDITIONING INVERTER. AC ALTERNATING CURRENT IN THE OPEN POSITION, A SIGN WILL BE 2. ALL INVERTERS AND ARRAYS ARE NEGATIVELY GROUNDED. BLDG BUILDING PROVIDED WARNING OF THE HAZARDS PER 3. THIS SYSTEM HAS NO BATTERIES, NO UPS. ® GRID —TIED INVERTER ''-'.SOIarCi �'� AR T. 690.17. 4. SOLAR MOUNTING FRAMING ARE TO BE GROUNDED. Dc CONC CONCRETE � . m`°T�,��`::�. DC DISCONNECT C COMBINER BOX PHOTOVOLTAIC AC DISCONNECT 2. EACH UNGROUNDED CONDUCTOR OF THE 5. ALL WORK TO BE DONE TO THE CURRENT UNIFORM BUILDING V—I D DISTRIBUTION PANEL WARNING! ELECTRIC SHOCK HAZARD! MULTIWIRE BRANCH CIRCUIT WILL BE CODE. AC DC DIRECT CURRENT OPERATING VOLTAGE V IDENTIFIED BY PHASE AND SYSTEM PER 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2008 AC DISCONNECT 2) �"� EGC EQUIPMENT GROUNDING CONDUCTOR MAXIM R A ART. 210.5. NATIONAL ELECTRIC CODE AS AMENDED BY THE OREGON (E) (EXISTING) 3. ANATIONALLY— RECOGNIZED TESTING ELECTRICAL SPECIALTY CODE. ® COMBINER BOX LABORATORY SHALL LIST ALL EQUIPMENT EMT ELECTRICAL METALLIC TUBING Solarcity „ GALV GALV GALVANIZED IN COMPLIANCE WITH ART. 110.3. O DISTRIBUTION PANEL PHOTOVOLTAIC DC DISCONNECT 4 GEC GROUNDING ELECTRODE CONDUCTOR CIRCUITS OVER 250V TO GROUND SHALL INDEX WARM:IELECTRICSMOCKNAZAR03 COMPLY WITH HDG HOT DIPPED GALVANIZED T ART. 250.97, 250.92(B) PHOTOVOLTAIC MODULE H (3) V 5. DC CONDUCTORS EITHER DO NOT ENTER PV1 COVER SHEET _ DG IP Vag, V lac A BUILDING OR ARE RUN IN METALLIC PV2 SITE PLAN • E VENT PIPE I CURRENT RACEWAYS OR ENCLOSURES TO THE FIRST () Imp INVERTERS AT MAX POWER Imp A PV3 STRUCTURAL VIEWS INVS INVERTER SOiarCity w'" ;:; °° ACCESSIBLE DC DISCONNECTING MEANS PV4 UPLIFT CALCULATION (E) SKYLIGHT Isc SHORT CIRCUIT CURRENT �" PER ART. 690.31(E). PV5 SINGLE LINE X KVA KILOVOLT AMPERE 6. ALL WIRES SHALL BE PROVIDED WITH PV6 ELECTRICAL CALCULATIONS (E) CHIMNEY KW KILOWATT Solar Disconnect STRAIN RELIEF AT ALL ENTRY INTO BOXES PV7 CUTSHEETS LBW LOAD BEARING WALL AS REQUIRED BY UL LISTING. PV8 CUTSHEETS MO DEDICATED kWh METER MIN MINIMUM �) WARNING — Electri ockHazard 7. MODULE FRAMES SHALL BE GROUNDED AT PV9 CUTSHEETS (N) (NEW) DO NOT TO 'ERMINALS THE UL— LISTED LOCATION PROVIDED BY NEC NATIONAL ELECTRIC CODE Terminals onb eantl load sides THE MANUFACTURER USING UL LISTED ma edfltheODenPosTon GROUNDING HARDWARE. LICENSE NIC NOT T IN CONTRACT O 8. ALL EXPOSED METAL PARTS (MODULE OC OMODULE OC O NT EN CENTER DC Disconnect RAIL, G BOXES, ETC.) SHALL LAY—IN B LUGS VICINITY MAP OR # 180498 PL PROPERTY OAR NES LISTED FOR THE PURPOSE. POSTS SHALL PV PHOTOVOLTAIC R. WARNING —Electric ock Hazard BE MADE ELECTRICALLY CONTINUOUS WITH �) DO NOT TO ERMINALS ATTACHED RAIL. SW fa rde St } S111 Gaarc St SW MIcDonald St T PVC POLYVINYL CHLORIDE crminals on bo :and s sid S SUBPANEL »aybe :n :r ^ 'ho O PonPosmo 9. MODULE FRAMES, RAIL, AND POSTS SHALL r L SCH SCHEDULE BE BONDED WITH EQUIPMENT GROUND R < SS STAINLESS STEEL DC VOLTAGE IS ALWAYS PRESENT WHEN CONDUCTORS AND GROUNDED AT THE w 10 SSD SEE STRUCTURAL DRAWINGS SOLAR MODULES ARE EXPOSED TO SUNLIGHT lo MAIN ELECTRIC PANEL. o STC STANDARD TESTING CONDITIONS (6) 10. IF THE EXISTING AC GROUNDING SWH SOLAR WATER HEATER So WARNING—Dual urcfioto a ystorn ELECTRODE IS A COPPER ROD, THE DC tai TYP TYPICAL GEC SHALL BE EITHER #8 THWN -2 RUN SIN .F 7- /r, UON UNLESS OTHERWISE NOTED 7 WARNING—EletlritlShockHazar INSIDE CONDUIT BONDED AT BOTH ENDS, C ) No useraervlceaDepartslnalda ' OR 6 B COPPER RUN ALONG c' SW Vitw Termot V VOLT Con acr aUH °r adaervi °art oraa,! ra nee # 9 ' i ( Vmp VOLTAGE AT MAX. POWER BUILDING AS LONG AS IT IS NOT SUBJECT, Voc VOLTAGE AT OPEN CIRCUIT ( 8) CAUTION TO PHYSICAL HARM PER ART. W SW llrt W WATT °`° 250.166(6) &(C), 250.64(B) &(E). IF THE ` rv!e SVid Canter My Ln 3R NEMA 3R, RAINTIGHT PV COMBINER BOX EXISTING AC GROUNDING ELECTRODE IS A �,� e�; C 9) WARNING: CONCRETE— ENCASED ELECTRODE, THE DC 501 "µ0 *Q ELECTRICSHOCKHAZARD GEC SHALL BE A #6 THWN -2 PER ART. cv REV BY DATE COMMENTS (1 0) 250.166(D). THE GEC SHALL BE SW Murdock RED' ` ' /' /' * O) ELE HAZARDIFAGROUND CONTINUOUS AS DESCRIBED IN ART. f1 "�' FAULT IS INDICATED.THE NORMALLY t' GROUNDED GIZED CONDUCTORS NGMAYBEENER- 250.64(C). GIZED AND UNGROUNDED ce 4.- I t '''' 11 WARNING ) stiw I NVERTER OUTPUT CONNECTION DO NOT RELOCATE �� , 1,...•••1,...•••,,t, THIS OVER CURRENT DEVICE ^ 1 14 1 .4*- E E.:; :rr, Ear: MODULES ,AV4 . trr ri' cusTOUER SV/4 ,idy # a i Dr a t% ∎ PROJECT MANA PRODUCT GROUP: CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT (36) KYOCERA # KD210GX -LPU JOHNSON, GARY AND BARBARA SIBLEY JOHNSON RESIDENCE ,� RESI BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR 7.56 kW ROOF MOUNT PV SYSTEM I t DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MDUN11NG SYSTP,l: CUSTOMER ADDRESS: SOLARCITY CANOPY C AND RAIL 11815 SW OR 97224 OD ST JOB NUMBLN: 393 Vintage Park Drive, Suite 140 TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE TIGARD, OR 97224 Foster City, CA 94404 DATE: PPA SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT MWRIER T:(650) 638-1028 I F:(650) 638-1029 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. (1) FRONIUS # IG PLUS 7.5 ( 5033410226 JB- 972045 R EV: 638 - (888) -SOL -CITY (765 -2489) I w 638 - arcity.com . LABELS ELECTRICAL NOTES GENERAL NOTES LEGEND ABBREVIATIONS PHDTGeaLTAIG POINt Or INtEACONNECTION WARNING! ELECTRIC SHOCK HAZARD! 1. WHERE ALL TERMINALS OF THE 1. THIS SYSTEM IS GRID- INTERTIED VIA A UL- LISTED — O (E) UTILITY METER A AMPERE - ( 1 ) . ..., : � ® �Y�� " DISCONNECTING MEANS MAY BE ENERGIZED POWER - CONDITIONING INVERTER. AC ALTERNATING CURRENT ) ° " IN THE OPEN POSITION, A SIGN WILL BE 2. ALL INVERTERS AND ARRAYS ARE NEGATIVELY GROUNDED. °a.aaoK.o,� GRID -TIED INVERTER BLDG BUILDING PROVIDED WARNING OF THE HAZARDS PER 3. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE ' ^' SOlarCit y .Z=Tco. ART. 690.17. 4. SOLAR MOUNTING FRAMING ARE TO BE GROUNDED. DC C COMBINER BOX PHOTOVOLTAIC AC DISCONNECT 2. EACH UNGROUNDED CONDUCTOR OF THE 5. ALL WORK TO BE DONE TO THE CURRENT UNIFORM BUILDING I-H DC DISCONNECT D DISTRIBUTION PANEL wARNINaI MIMIC SHOCK HAZARDI MULTIWIRE BRANCH CIRCUIT WILL BE CODE. OPERATING VOLTAGE V IDENTIFIED BY PHASE AND SYSTEM PER 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2008 AC AC DISCONNECT DC DIRECT CURRENT �''� EGC EQUIPMENT GROUNDING CONDUCTOR MAXIMUM OOP RATING A ART. 210.5. NATIONAL ELECTRIC CODE AS AMENDED BY THE OREGON (E) (EXISTING) 3. A NATIONALLY- RECOGNIZED TESTING ELECTRICAL SPECIALTY CODE. ® COMBINER BOX LABORATORY SHALL LIST ALL EQUIPMENT EMT ELECTRICAL METALLIC TUBING °,, Solarcity s«` <ow IN COMPLIANCE WITH ART. 110.3. O DISTRIBUTION PANEL GALV GALVANIZED PNOIOYOITAIC DC DISCONNECT 4 GEC GROUNDING ELECTRODE CONDUCTOR CIRCUITS OVER 250V TO GROUND SHALL INDEX GROUND DIPPED COMPLY WITH ART. 250.97, 250.92(B) PHOTOVOLTAIC MODULE HDG Y 5. DC CONDUCTORS EITHER DO NOT ENTER PV1 COVER SHEET — DG IPPED GALVANIZED ( 3 ) V BUILDING OR ARE RUN IN METALLIC PV2 SITE PLAN • E VENT PIPE I CURRENT A RACEWAYS OR ENCLOSURES TO THE FIRST PV3 STRUCTURAL VIEWS () Imp INVERT ERS R AT MAX POWER ® Imo INVS INVERT SOlartity w.;,e. °9v ACCESSIBLE DC DISCONNECTING MEANS PV4 UPLIFT CALCULATIO (E) SKYLIGHT Isc SHORT CIRCUIT CURRENT PER ART. 690.31(E). PV5 SINGLE LINE X KVA KILOVOLT AMPERE 6. ALL WIRES SHALL BE PROVIDED WITH PV6 ELECTRICAL CALCULATIONS (E) CHIMNEY KW KILOWATT Solar Disconnect STRAIN RELIEF AT ALL ENTRY INTO BOXES PV7 CUTSHEETS LBW LOAD BEARING WALL AS REQUIRED BY UL LISTING. PV8 CUTSHEETS O DEDICATED kWh METER MIN MINIMUM 4 WARNING– Eleetri ckHazard 7. MODULE FRAMES SHALL BE GROUNDED AT PV9 CUTSHEETS MI (NEW) (N) NEW DO NOT TO RMINALS THE UL- LISTED LOCATION PROVIDED BY NEC NATIONAL ELECTRIC CODE Terminals on Nand Loadsldes THE MANUFACTURER USING UL LISTED may be ener, ed in the open POSIGon. LICENSE NIC NOT IN CONTRACT GROUNDING HARDWARE. S NOT ALE 8. ALL EXPOSED METAL PARTS (MODULE OC ON CENTER DC Disconnect FRAMES, RAIL, BOXES, ETC.) SHALL BE OR # 180498 P PANEL BOARD GROUNDED USING UL LISTED LAY -IN LUGS VICINITY MAP PL PROPERTY LINES LISTED FOR THE PURPOSE. POSTS SHALL PV PHOTOVOLTAIC WARNING ockHazard BE MADE ELECTRICALLY CONTINUOUS WITH DO NOT TO RMINALS ATTACHED RAIL. SW fig ®[de St SW Gaa de St SW M and Load sides PVC SOBPANEL CHLORIDE ) Terminals on b may be°ner ed in the Open Position. 9. MODULE FRAMES, RAIL, AND POSTS SHALL d BE BONDED WITH EQUIPMENT GROUND" SCH SCHEDULE SW CiPie r SS STAINLESS STEEL DC VOLTAGE IS ALWAYS PRESENT WHEN CONDUCTORS AND GROUNDED AT THE SOUR MODULES AREEYPOSFD TO SUNLIGHT P. SSD SEE STRUCTURAL DRAWINGS MAIN ELECTRIC PANEL. 10. IF THE EXISTING AC GROUNDING a STC STANDARD TESTING CONDITIONS 6 WARNING —Dual Power Sources SWH SOLAR WATER HEATER ( ) Second source ls photovoltaic system ELECTRODE IS A COPPER ROD, THE DC 40 g a TYP TYPICAL GEC SHALL BE EITHER #8 THWN -2 RUN SW Me fu *` �f,�, UON UNLESS OTHERWISE NOTED ( 7 ) `WARNNouaarsenlceabbING- ElectricShockHtla aza�, INSIDE CONDUIT BONDED AT BOTH ENDS, 6 4, qtr V y V VOLT ) v� erto, ai OR BARE COPPER RUN ALONG Conlacl sentcarTorawiatanw #6 5 { Vmp VOLTAGE AT MAX. POWER 8 ) CAUTION BUILDING AS LONG AS IT IS NOT SUBJECT Voc VOLTAGE AT OPEN CIRCUIT `V J � �M TO PHYSICAL HARM PER ART. ` VVI ° �.r �• SW Wm W WATT °`"' "`" " °mss "` ° " "'"' "° 250.166(8) &(C), 250.64(B) &(E). IF THE 1. Q p, 3R NEMA 3R, RAINIIGHT �SOiWt Camleftu ry Ln PV COMBINER BOX EXISTING AC GROUNDING ELECTRODE IS A ( 9) WARNING: CONCRETE- ENCASED ELECTRODE, THE DC 5W gui�40 �y F. - ELECTRICSHOCKHAZARD GEC SHALL BE A #6 THWN -2 PER ART. ` REV BY DATE COMMENTS 1 WARNING 250.166(D). THE GEC SHALL BE Ff' REV * * e / / e 0) ELECTRICAL SHOCK NAZARDIFAGROUND CONTINUOUS AS DESCRIBED IN ART. dl PJlu'dQk1 ' FAULT IS INDICATED.THE NORMALLY y b , GROUNDED CONDU M AYBE ENER 250.64(C). $'. ±"T GIZEDANDUNGROUNDED el / 4 11 INVERTER OUTPUT CONNECTION WARNING SW As .$ I►1 4 DO NOT RELOCATE # �� � t /� THIS OVER CURRENT DEVICE 09 = w �� SW 1d Mallon, Dr Ai�i�� \� 10 ralrAk itica mrolb� , I'I I • - [I L' I - t ,. S .. GR - PROJECT MANAGER: PRODUCT JP: CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT (36) KYOCERA # KD210GX -LPU JOHNSON, GARY AND BARBARA SIBLEY JOHNSON RESIDENCE ,, RESI BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR 7.56 kW ROOF MOUNT PV SYSTEM DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MWNTING SYSTE)A: CUSTOMER ADDRESS TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE S OLARCITY CANOPY C AND RAIL 11815 SW WILDWOOD ST JOB NUMBER: 393 Vintage Park Drive, Suite 140 TIGARD, OR 97224 Foster City, CA 94404 DATE: PPA SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT INVERTER. T:(650) 638 -1028 I F:(650) 638 -1029 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. (1) FRONIUS # IG PLUS 7.5 (240) 5033410226 J B- 972045 00 REV: (888).SOL -CITY (765 -2489) I www.solarcity.com SITE PLAN �� Scale: 3/32" = 1' kr ` ROOF PENETRATION 4, ir 55' 1 MP1 ROOF MOUNT 1 TO PITCH: 18 ARRAY PITCH: 18 GATE O R e AZIMUTH: 204 ARRAY AZIMUTH: 204 r MATERIAL: Comp Shingle Roof STORY: 1 o AFTERS Inv ; ❑ SIZE: 2X8 0 © SPACING: 16 O.C. 1 A SUPPORT: 2X4 TRUSS 25' AC PV3 MAX. SP Nr 16' -0" TOR 411 H-H ES ❑ TOTAL ARRAY AREA 590 SQFT. 0 0'.. D ; ROOF AREA: 5,270 SQFT STRUCTURE 11.2 % PV ROOF COVERAGE CHANGE $- 0 (4) X X - 1 C X x . PV3 SHEET NOTES n 1. INVERTER, DC DISCONNECT, & WARNING LABELS (2), B I (3), (5). 65' 2. DEDICATED PV SYSTEM METER. PV3 I TO5R 3. AC DISCONNECT & WARNING LABELS (1), (2), (4), (TYP) (6) 4. UTILITY METER. 5. UNUSED 6. DC COMBINER BOX & WARNING LABELS (7), (9). 7. UNUSED 8. DISTRIBUTION PANEL & WARNING LABELS (1), (2), (4), (6). 9. CONDUIT ROUTED THROUGH INTERIOR & WARNING LABEL (8). 10. CONDUIT ROUTED ON ROOF 01' 10' 21' ) 11. CONDUIT ROUTED ON WALL 30 12. REFER TO PV1 FOR WARNING LABELS II ■ TO R • P V ' Vit f 4 2 .0 walls' CUSTOMER: DESCRIPTION: �' 0 I in I + N 4 i , • PROJECT MANAGER: R CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT (36) KYOCERA # KD210GX -LPU JOHNSON, GARY AND BARBARA SIBLEY JOHNSON RESIDENCE REST BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC. NOR 7.56 kW ROOF MOUNT PV SYSTEM i DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MOUNTING SYSTEM: CUSTOMER ADDRESS TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE S OLARCITY CANOPY C AND RAIL 11815 SW OR 97224 OD ST TIGARD, OR 97224 )3B NUMBER 393 Vintage Park Drive, Suite 140 DATE: PPA SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT INVERT : Foster City, CA 94404 B- 972045 00 7:(650)638.1028 I F:(650) 638 -1029 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. (1) FRONIUS # IG PLUS 7.5 ( 5033410226 REV: (888)-SOL-CITY (765-2489) I www.solarcity.com SITE PLAN 1 Scale: 3/32" = 1' Oil) R OOF PENETRATION MP1 ROOF MOUNT tr 55 PITCH: 18 ARRAY PITCH: 18 GATE • O TO R AZIMUTH: 204 ARRAY AZIMUTH: 204 r. MATERIAL: Comp Shingle Roof ❑ � STORY: 1 0 RAFTERS Inv ; ❑ SIZE: 2X8 o SPACING: 16 O.C. A SUPPORT: 2X4 TRUSS 25TO ' R AC PV3 MAX. SPAN 16' —O" - I S 0 I= TOTAL ARRAY AREA 590 SQFT. M D ` ,t ROOF AREA: 5,270 SQFT — — -' ; STRUCTURE O _ 11.2 % PV ROOF COVERAGE CHANGE 0 O xx y —Lx H PV SHEET NOTES r— 1. INVERTER, DC DISCONNECT, Sc WARNING LABELS (2), B I ( ( 2. DEDICATED PV SYSTEM METER. PV3 - To 3. AC DISCONNECT Sc WARNING LABELS (1), (2), (4), TYP I 1 ( ) (6). 4. UTILITY METER. 5. UNUSED 6. DC COMBINER BOX & WARNING LABELS (7), (9). 7. UNUSED 8. DISTRIBUTION PANEL Sc WARNING LABELS (1), (2), (4), (6). 9. CONDUIT ROUTED THROUGH INTERIOR Sc WARNING LABEL (8). 10. CONDUIT ROUTED ON ROOF O 1' 10' 21' 30' 11. CONDUIT ROUTED ON WALL ■�����■ t 12. REFER TO PV1 FOR WARNING LABELS � TO R • j PV ` ∎�� d 2 i ". PROJECT MANAGER: P D DUCr GROU : CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT MSS (36) KYOCERA # KD21OGX LPU CUSTOMER: DESCRIPTION: • I�; , RESI BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR JOHNSON GARY AND BARBARA SIBLEY JOHNSON RESIDENCE MOUNTING— SYSTEM: 7.56 kW ROOF MOUNT PV SYSTEM I DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE cusTaMER ADDRESS: TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SOLARCITY CANOPY C AND RAIL 11815 SW WILDWOOD ST NUMBER: 393 Vintage Park Drive, Suite 140 JOB , S ALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT TIGARD OR 97224 DATE: PPA INVERTER: B- 972045 00 Foster City, CA 94404 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. (1) FRONIUS # IG PLUS 7.5 ( 5033410226 REV: T: I F(650)638 -1029 (888) -SOL -CITY -CITY ( (765 -2 765 -2489) I www.solarcity.com IF 1 (E) 2x8 / 4' BETWEEN / _ RAFTERS (E) 4x12 AR —__� __p — —11ki BEAM \- (E) LBW N N 09 N I / 1' -4" TYP (E) 2x8 RAFTERS 2' -2" I! 10' -2" / 10' / 11' - e © 16" SPACING + (E) LBW SIDE VIEW OF MP1 RAFTERS 2X 8 2 BEACP O . C . + FRONT VIEW OF MOUNTING PLANE (TYP) . Scale: 1/ B MAX SPAN: 11' -1" Scale: 1/2 " =1' -0" 4 " =1' 0" 1 STANDOFF o SOLAR PANEL D Scale: 1 1/2 = 1' INSTALLATION ORDER MII /� (E) 2x8 ATTACHED WITH MODULE / LOCATE RAFTER, MARK HOLE ." RAFTERS RAFTERS CLAMPS, 11 BOLTS, AND CHANNEL NUT (1) HOLE. CUT SHINGLE L AR AROUND 4.10----- �� (E) LBW SOLARCITY SOLAR RAIL \ FLASHING COLLAR. & BOLT _ (4) SEAL PILOT HOLE AND BOTTOM (E) 2x12 CANOPY BOLT ASSEMBLY � ' ( 3 ) (2) OF CANOPY BASE WITH JOISTS ir POLYURETHANE SEALANT. & BRACKET CANOPY FLASHING / LAG CANOPY BRACKET IN 2' - i 16 /1' -7 "/ -2' -9" j _ _ ` �,� 1 (3) RAFTER WITH (1) a" DIA. LAG (E) LBW (E) COMP. SHINGLE - �� BOLT IN HOLE CLOSEST TO 1 + (E) LBW POST. RAFTERS: 2x8 ®16" O.C. (E) ROOF DECKING INSTALL CANOPY FLASHING ONTC SUPPORT: 2x4 TRUSS " DIA LAG BOLT ( BRACKET. ATTACH RAIL WITH MAX SPAN: 16' -0" (2-1" EMBED, MIN) CANOPY CLAMP. (E) RAFTER A SIDE VIEW OF MP1 Scale: 1/4 " =1' -0" • P V `N ►, ,i 3 '. 0 I Am TMOW�S CUSTOMER: DESCRIPTION: e , � , to. ;,..s i 'ty PROJECT MANAGER: P ODl1CT P: CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT (36) KYOCERA # KD210GX -LPU JOHNSON, GARY AND BARBARA SIBLEY JOHNSON RESIDENCE BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR 7.56 kW ROOF MOUNT PV SYSTEM Ly. DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE /AWING SYSIEN: CUSTOMER ADDRESS TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE S OLARCITY CANOPY C AND RAIL 11815 SW WILDWOOD ST TIGARD, OR 97224 JOB NUMBER 393 Vintage Park Drive, Suite 140 DATE: PPA SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT IN's Foster City, CA Drive, 94404 ui ]B- 972045 00 T:(650)638 -1028 I F:(650)638 -1029 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. (1) FRONIUS # IG PLUS 7.5 ( 5033410226 REV: (888)-SOL-CITY (765 -2489) I w) 638-1029 CI (E) 2x8 / 4' BETWEEN T �i� RAFTERS I� (E) 4x12 �- -_ ___m__--/14 _ BEAM (E) LBW i N N )s N X X 1- 4" TYP 1 (E) 2x8 RAFTERS 2' -2" (! 10' -2" / 10' / 11' -1" ® 16" SPACING r (E) LBW RAFTERS: 2x8 © 16" O.C. + FRONT VIEW OF MOUNTING PLANE (TYP) . SIDE VIEW OF MP1 SUPPORT: 4X12 BEAM Scale: 1/4 " = 1' -0" B MAX SPAN: 11' -1" Scale: 1/2 " =1' -0" STANDOFF o SOLAR PANEL D Scale: 1 1/2" " - 1' I INSTALLATION ORDER I �� (E) 2x8 ATTACHED WITH MODULE LOCATE RAFTER, MARK HOLE ," RAFTERS CLAMPS, f1 BOLTS, ( LOCATION, AND ( PILOT �i� �— (E) LBW AND CHANNEL NUT HOLE. CUT SHINGLE AROUND �� SOLARCITY SOLAR RAIL \ FLASHING COLLAR. & BOLT (4) SEAL PILOT HOLE AND BOTTOM CEILING CANOPY BOLT ASSEMBLY amity/am (3) ( OF CANOPY BASE WITH JOISTS POLYURETHANE SEALANT. lird CANOPY FLASHING / LAG CANOPY BRACKET IN Il 8c BRACKET _ J �s.�. - (1) (3) RAFTER WITH (1) a" DIA. LAG 2' -2' 16' /1' -7" 2' -9" (E) COMP. SHINGLE _ m.� BOLT IN HOLE CLOSEST TO 1 (E) LBW --f- (E) LBW ZWIRI POST. RAFTERS: 2x8 @ 16" O.C. (E) ROOF DECKING NSTALL CANOPY FLASHING ONTC SUPPORT: 2x4 TRUSS " DIA LAG BOLT ( BRACKET. ATTACH RAIL WITH MAX SPAN: 16' -0" \ CANOPY CLAMP. (2-" EMBED, MIN) (E) RAFTER SIDE VIEW OF MP1 A U Scale: 1/4 " =1' -0" P 3 V = �i 1� ' P ROJECT MANAGER: PR UCr TTiAA1LE5 Er CUSTOMER: DESCRIPTION: , +,, CROUP: CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT (36) KYOCERA # KD210GX LPU JOHNSON, GARY AND BARBARA SIBLEY JOHNSON RESIDENCE �i RESI BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR 7.56 kW ROOF MOUNT PV SYSTEM malty DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MOJNUNG SYSTEM: CUSTOMER ADDRESS: TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE S OLARCITY CANOPY C AND RAIL 11815 SW WILDWOOD ST TIGARD, OR 97224 JCR NBQ7 393 Vintage Park Drive, Suite 140 DATE: PPA SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT INV 3 B- 972045 00 94404 RTER: T :I650) Vintage City, Suite 638 140 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. (1) FRONIUS # IG PLUS 7.5 ( 5033410226 REV: (888)- sot 0) Foster Ci638 -1028 I Drive, ty, CA s) I w) 638-1029 Input Variables Calculations and Values Required Variables Design wind pressures based upon: Mean roof height: 18 ASCE 7 -05 Chapter 6 Wind Loading Exposure category: C Basic wind speed (or city in the future): 90 Equation 6.5.13.3: Component and Cladding Elements Importance factor (1 for residential): 1 Wind pressure P = qh *Cn *G Roof shape: one plane 6.5.10: Velocity pressure Roof angle (degrees): 18 qh = 0.00256 *Kz *Kzt *Kd *V ^2 *I Roof zone: 3 Contiguous sq. feet of array: 64 From Table 6-3: Least width of the building: 20 Kz = 0.88 Obstructed wind flow? TRUE From Figure 6-4: Kzt = 1.00 Local Topograhphical Features From Table 6-4: (choose "standard "or refer to pictures right, and below) Kd = 0.85 Type of hill: none From figure 6 -1: Hill height (h) (ft): V = 90 Slope of hill (degrees): From table 6 -1: Horizontal distance from hilltop to house (x): I = 1 eight from bottom of hill to mean roof height (z): From Velocity Pressure Equation: qh = 15.51 Design Wind Pressures From Figure 6-19A P (lbs. per sq. ft.) = qh *Cn *G Cn (uplift) = -2.14 Pd (downforce pressure) = 16.88 Cn (down) = 1.28 Pu (uplift pressure) = -28.21 From 6.5.8.1 G = 0.85 Max Tributary Area Feet Inches Individual Rows in Portrait X (E -W distance between standoffs) = 4 0 Kyocera KD210GX LP Y (N -S distance between standoffs) _ 3 5 Amax (sq. ft.) = 0.5 *L *X L (length of panel in ft. perpendicular to rail) 4.93 X= 4.00 Module Rail Max. Span / Cantilever (in) = 77 1/2 36 1/2 Y = 3.42 Max Uplift Force on a Single Standoff L = N/A Pmax (lbs.) = Amax *Pu Amax = 9.85 ( Pmax = -278 Factor of safety = Fl *D *NI /Pmax 250 = Fl (pullout capacity of lag (lbs/inch)) Dead Load Calculations 2.50 = D (minimum lag thread depth) DL (lbs/sq. ft.) = (Mm+Mh) /(L *W) 1 = NI (number of lags per standoff) L (length of Kyocera KD210GX LP modules) 4.93 2.25 = Factor of safety W (width of Kyocera KD210GX LP modules) 3.25 Mm (weight of Kyocera KD210GX LP modules) 40.80 Point Load Calculations Mh (weight of hardware per module) = 8.43 PL (Ibs) = Amax *DL PL =30 DL = 3.08 Version 5_6 PV = ••4 i 4 • Y A7.1_D ScrLarrQ1YDETA1Lt: MODULES: CUSTOMER: DESCRIPTION: P i PROJECT MANAGER: PRODUCT GROUP: CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT RESI BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC. NOR (36) KYOCERA # KD210GX LPU JOHNSON GARY AND BARBARA SIBLEY JOHNSON OO SI M ENCE , DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MOUNTING SYSTEM: CUSTOMER ADDRESS 7.56 kW ROOF MOUNT PV SYSTEM t TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SOLARCITY CANOPY C AND RAIL 11815 SW WILDWOOD ST be NUMBER 393 Vintage Park Drive, Suite 140 TIGARD, OR 97224 DATE: PPA SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT INA-RTER: 3B-972045 00 Foster City, CA 94404 T:(650) 638 -1028 I F:(650) 638 -1029 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. (1) FRONIUS # IG PLUS 7.5 (240) 5033410226 REV: (888)_SOL -CITY (765 -2489) I www.solarcity.com Input Variables Calculations and Values Required Variables Design wind pressures based upon: Mean roof height: 18 ASCE 7 -05 Chapter 6 Wind Loading Exposure category: C Basic wind speed (or city in the future): 90 Equation 6.5.13.3: Component and Cladding Elements Importance factor (1 for residential): 1 Wind pressure P = qh *Cn *G Roof shape: one plane 6.5.10: Velocity pressure Roof angle (degrees): 18 qh = 0.00256 *Kz *Kzt *Kd *VA2 *I Roof zone: 3 Contiguous sq. feet of array: 64 From Table 6 -3: Least width of the building: 20 Kz = 0.88 Obstructed wind flow? TRUE From Figure 6-4: Kzt = 1.00 Local Topograhphical Features From Table 6-4: (choose "standard " or refer to pictures right, and below) Kd = 0.85 Type of hill: none From figure 6 -1: Hill height (h) (ft): V = 90 Slope of hill (degrees): From table 6 -1: Horizontal distance from hilltop to house (x): I = 1 eight from bottom of hill to mean roof height (z): From Velocity Pressure Equation: qh = 15.51 Design Wind Pressures From Figure 6 -19A P (lbs. per sq. ft) = qh *Cn *G Cn (uplift) = -2.14 Pd (downforce pressure) = 16.88 Cn (down) = 1.28 Pu (uplift pressure) = -28.21 From 6.5.8.1 G = 0.85 Max Tributary Area Feet Inches Individual Rows in Portrait X (E -W distance between standoffs) = ' 4 0 Kyocera KD210GX LP Y (N -S distance between standoffs) = 3 5 Amax (sq. ft.) = 0.5 *L *X L (length of panel in ft. perpendicular to rail) 4.93 X = 4.00 Module Rail Max. Span / Cantilever (in) = 77 1/2 36 1/2 Y = 3.42 Max Uplift Force on a Single Standoff L = N/A Pmax (lbs.) = Amax *Pu Amax = 9.85 ( Pmax = -278 Factor of safety = FI *D *NI /Pmax 250 = Fl (pullout capacity of lag (lbs/inch)) Dead Load Calculations 2.50 = D (minimum lag thread depth) DL (lbs/sq. ft.) = (Mm +Mh) /(L *W) 1 = NI (number of lags per standoff) L (length of Kyocera KD210GX LP modules) 4.93 2.25 = Factor of safety W (width of Kyocera KD210GX LP modules) 3.25 Mm (weight of Kyocera KD210GX LP modules) 40.80 Point Load Calculations Mh (weight of hardware per module) = 8.43 PL (Ibs) = Amax *DL PL= 30 DL = 3.08 Version 5_6 • PV • 4 411; v Ac.i.0 RUTY DETAILS: S MODULES: CUSTOMER: DESCRIPTION: Pr, I I my PROJECT MANAGER: PRODUCT GROUP: CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT RESI BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR (36) KYOCERA # KD210GX LPU JOHNSON GARY AND BARBARA SIBLEY JOHNSON RESIDENCE 7.56 kW ROOF MOUNT PV SYSTEM DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MWNIING SYSItM: CUSTOMER ADDRESS TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SOLARCITY CANOPY C AND RAIL 11815 SW WILDWOOD ST )oa NUMBER: 3 93 Vintage Park Drive, Suite 140 DATE: PPA SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT 5033RD, OR 97224 Foster City, CA 94404 IN�RT�' B - 972045 00 T 638 -1028 I F:(650) 638 -1029 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. (1) FRONIUS # IG PLUS 7.5 ( 5033410226 REV (888) -SOL -CITY (765 -2489) I www.solarcity.com MODULE VOLTAGE RATINGS ' Voc: 33.2 VDC Vpmax: 26.6 VDC LINE DRAWING 36 MODULES ON MP1 DC + - *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN THE DC A In ^ n n n n n n n n n ^ STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. ig ig tg ig ig ig 14 ig DI IA ig °° i I — — — — — — — — — — — — — — I DC + , ,- - + 7 " DC- �/ ° I 4, ( 6)AWG #10, USE- 2 /RHW -2, Black GEC AWG #6, Stranded Bare Copper (1)__ 1 i r ° Imp (1) A WG #6 Stranded Bare Co er i i i i PP - - -- -- - -- - - -- - - -- -- - -- -e"°� i i - , • Voc = 398.4 VDC DC+ I , • Vmp = 319.2 VDC Ground Rod; 5/8" x 8', Copper (1) 1 , i I nnnnnnnnn i i • Isc = 8.58 ADC _ 2 12 22is is 2 Ci 2 al 2 ��' D� - - -1 i I • Im = 7.9 ADC � I I I i (N) ARRAY GROUND PER 690.47(D). ; I - - - - - - - - - - - - - - - - NOTE: PER EXCEPTION NO. 2, ADDITIONAL (36) KYOCERA # KD210GX -LPU ' ELECTRODE MAY NOT BE REQUIRED I I PV Module; 210W, 189.8W PTC l I 1 DEPENDING ON LOCATION OF (E) ELECTRODE. i I I i ( 1 ) SHOALS # STG- CBRH -3 -a Combiner Box; 3 String, 90A, 600V, NEMA 4 — ( 1 ) Multi -Cable Connector, 3 Port FRONIUS # IG PLUS 7.5 ( 1 ) #4 - #14 AWG, Same side, Insulated Inverter; 7500W, 240V, 95.5% EFF. I ( 3 ) FERRAZ SHAWMUTT # ATM15 (E) 200 MAIN ELECTRIC SERVICE PANEL LABEL INVERTER: A EGC Dc - DC+ I Fuse; 15A, 600VDC, Midget (E) WIRES & CONDUIT (E) 200 MAIN CIRCUIT BREAKER INSIDE I I I i I i ( 1 ) SQUARE D # HOM240 i i I Breaker; 40A, 2 Pole, 240V ; ; i ( 1 ) AWG #6, THWN -2, Black AC DISCONNECT , INVERTER , g— ( 1 ) AWG IIWN -2, White I--� (E) LOADS PER ART. 690.17 © BOTTOM OF PANEL ; I N I GND –A I • , r— N � , , , ( 1 ) AWG #6, THWN -2, Green EGC ( 1 ) SQUARE D # DU322 , I Dc IDC- IEGC i I U '� Disconnect 60A, 240V, NEMA 1 I G I I i I I — ( 1 ) Conduit Kit; 3/4" EMT MOUNTED NEXT TO SERVICE METER I 1 1 ; • Voc = 398.4 VDC I I I m • A ' I i i I I • Vmp = 319.2VDC • B i I �_ F i EGC j DC • Isc = 25.74 ADC TOP BOTTOM L L DC+ • Imp = 23.7 ADC /� Lt L1 I P _i_ I , LINE -. L2 LOAD • • L2 � N N N I GND _ _ _ _ _ _ _m_ _ _EGC /GEJ ( ) FRONIUS # 42,0201,2923 Z – 6 1 _ EGC /GEC , EGC/GEC 8 JUMPER Inverter Input String Combiner # (2) T &B ADR2 IGEC UNBROKEN THROUGH EQUIP. Lay In Lug; 1 Hole Mount, 2 -14 AWG i 1 #8 JUMPER , DC DISCONNECT 1 INTEGRATED INTO ' (1) AWG #8, THWN -2, Black INVERTER; COMPLIES m TO 12O/240V BOND (N) #6 EGC /GEC TO (E) — ( 1 ) AWG #8, THWN -2, Red WITH NEC. SINGLE PHASE GROUND ROD OR (E) GEC IN UTILITY SERVICE PANEL WITH IRREVERSIBLE M2 (1 ) AWG #10, THWN -2, White NEUTRAL CRIMP PER ART. 250.64(C) (1 ) AWG #6, THWN -2, Green EGC /GEC (1) COOPER # B Line Meter Socket 011 (1 ) Conduit Kit; 3/4" EMT Meter Socket; 125A, 4- 14AWG, Ring Type • Vmp = 240 VAC • Imp = 31.3 AAC METER TO BE PROVIDED BY UTILITY PV ,,, MOUNTED NEXT TO SERVICE METER 5 NI OJSTO� I + ,, PRO�cr MANAGER GD : P: CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT MOOD ES MER: DESCRIPTION: � (36) KYOCERA # KD210GX -LPU JOHNSON, GARY AND BARBARA SIBLEY JOHNSON RESIDENCE �� RESI BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR 7.56 kW ROOF MOUNT PV SYSTEM SoiarC DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MOUNIING SYSTEM: CUSTOMER ADORES& TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE S OLARCITY CANOPY C AND RAIL 11815 SW WILDWOOD ST TIGARD, OR 97224 q8 NUMBER 393 Vintage Park Drive, Suite 140 DATE: PPA SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT IN ER Foster City, CA 94404 JB- 972045 00 T:(650)638 -1028 I F:(650) 638 -1029 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. (1) FRONIUS # IG PLUS 7.5 (240) 5033410226 REV: (888) -SOL -CITY (765 -2489) I www.solarcity.com MODULE VOLTAGE RATINGS Voc: 33.2 VDC Vpmax: 26.6 VDC LINE DRAWING 36 MODULES ON MP1 DC + *MODULE CURRENT RATINGS ARE SHOWN AS In AND Imp IN THE DC A In n n n n n n n n n n n STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. lA W W W W W W W �.11 r4 °C I - - - - - - - - - - - - - - - --- —6N.D, I DC + L . I ' °C _ r , i i $ AWG #6, Stranded Bare Copper (1) I GEC I ( AWG 10, USE-2/RHW-2, Black ig W W NI ig ig ig I I I ( 1 ) AWG #6, Stranded Bare Copper I I - - -- -- - -- - - -- - - -- -- - -- -� I • Voc = 398.4 VDC DC+ I I • Vmp = 319.2 VDC I Ground Rod; 5/8" x 8', Copper (1) �J I I _ I • Ise = 8.58 ADC n n nnnnnnnnnn - i , ~I �_ �ig ig Wig Wig �W14 � D � I • Imp = 7.9 ADC I I (N) ARRAY GROUND PER 690.47(D). ; I - - - - - - - - - - - - - - - - - - - - - i NOTE: PER EXCEPTION NO. 2, ADDITIONAL I ' (36) KYOCERA # KD210GX -LPU I I I I ELECTRODE MAY NOT BE REQUIRED I I PV Module; 210W, 189.8W PTC -1 I , DEPENDING ON LOCATION OF (E) ELECTRODE. = - L - - ; � I ( 1 ) SHOALS # STG-CBRH-3-a I I j Combiner Box; 3 String, 90A, 600V, NEMA 4 1 �1 — ( 1 ) Multi -Cable Connector, 3 Port FRONIUS # IG PLUS 7.5 (1) ' #4 - #14 AWG, Same side, Insulated Inverter; 7500W, 240V, 95.5% EFF. ( 3 ) FERRAZ SHAWMUTT # ATM15 (E) 200 MAIN ELECTRIC SERVICE PANEL LABEL INVERTER: A EGCI DC- DC+ Fuse; 15A, 600VDC, Midget (E) WIRES & CONDUIT I � (E) 200 MAIN CIRCUIT BREAKER INSIDE ( 1 ) SQUARE D # HOM240 I I Breaker; 40A, 2 Pole, 240V ( 1 ) AWG #6 THWN -2 Black AC DISCONNECT INVERTER i o (1) AWG #6, THWN -2, White (E) LOADS PER ART. 690.17 ® BOTTOM OF PANEL ; © _ GND - GF I • , I I I I I (1 ) AWG #6, THWN -2, Green EGC ( 1 ) SQUARE D # DU322 , I DC IOC- IEGC 111 U • Disconnect; 6OA, 24OV, NEMA 1 I ; G I ' I I ( Conduit Kit; 3/4" EMT MOUNTED NEXT TO SERVICE METER i i I I i I i • Voc = 398.4 VDC • A ' I i ' ' • Vmp = 319.2 I • B i I I L _ F i EGC DOJ • Isc = 25.74 ADC TOP BOTTOM L _ L DC+ • Im = 23.7 ADC /'� L1 — __ L1 I P /--' LINE \ L2 LOAD - ♦ — .- L2 I N N II N 1 _ — — — _ _ _ _ _ —M- — _ EGC /GEJ ( 2 ) FRONIUS # 42,0201,2923 Z _ z EGC /GEC GND EGC/G # JUMPER Inverter Input String Combiner L ' 1 i GEC (2) T La e In Lug; 1 Hole Mount, 2 -14 AWG UNBROKEN THROUGH EQUIP. #8 JUMPER DC DISCONNECT INTEGRATED INTO (1 ) AWG #8, THWN -2, Black INVERTER; COMPLIES TO 120/240V BOND (N) #6 EGC /GEC TO (E) — SINGLE PHASE GROUND ROD OR (E) GEC IN (1) AWG #8, THWN -2, Red WITH NEC. UTILITY SERVICE PANEL WITH IRREVERSIBLE (1 ) AWG #10, THWN -2, White NEUTRAL CRIMP PER ART. 250.64(C) (1 ) AWG #6, THWN -2, Green EGC /GEC (1) COOPER # B Line Meter Socket 011 (1 ) Conduit Kit; 3/4" EMT Meter Socket; 125A, 4- 14AWG, Ring Type • Vmp = 240 VAC • Imp = 31.3 AAC METER TO BE PROVIDED BY UTILITY PV f4 lb.. r. MOUNTED NEXT TO SERVICE METER 5 .417 s -,,,,,,, 0 I dim V Az1.O S()1_ARCTfYOEIAILS MODULES: CUSTOMER: DESCRIPTION: I / t . PROJECT MANAGER: PRODUCT GROUP: CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT RESI BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC. NOR (36) KYOCERA # KD210GX -LPU JOHNSON GARY AND BARBARA SIBLEY JOHNSON RESIDENCE 7.56 kW ROOF MOUNT PV SYSTEM i 'ty. DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MOUNIING SYSTEM: CUSTOMER ADDRESS: TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SOLARCITY CANOPY C AND RAIL 11815 SW WILDWOOD ST NOMg�. 393 Vintage Park Drive, Foster City, CA 94404 JOB Suite 140 TIGARD, OR 97224 DATE: PPA SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT INVERTER: ]B- 972045 00 T:(650)638 -,028 I F:(650)638 -,029 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. (1) FRONIUS # IG PLUS 7.5 ( 5033410226 REV: (888) -SOL -CITY (765 -2489) I www.solarcity.com 1. Conductor Sizing per Art 690.8(6)(1) Module: 36 Kyocera KD210GX -LPU 189.8 Inv Pwr W PTC Voltage Drop Calculations Version 5_6.4 a. Conductor must have 30 deg. ampacity >= 125% of continuous current per Art 215.2(A)(1). Inverter 1: 1 Fronius IG Plus 7.5 -1 (240) 95.5% 7,500 Vdrop = (Imp) * (2 * Length) * (Resistance) / (Vmp) Module: Imp (A) Max. Length (ft) Wire • b. Conductor must have (after corrections for conditions of use) Inverter 2: MN String: 7.9 50 C AWG 1C at Max Ave Hi: 80 deg F >= continuous current per Table 310.16. Module: Vdrop = (7.90 A * 100 it • 0.00124 Ohms) / 292 V = 0.34% Inverter 3. Branch: 1 23.7 I 50 IE AWG 01 at Max Ave Hi: 80 deg F c. Evaluate conductor temperature at terminations per 110.14(C). Module: Vdrop = (23.70 A * 100 ft * 0.00049 Ohms) / 292 V = 0.40% Ampacity of wire derated for conditions of termination must Inverter 4: Total voltage drop in DC conductors = 10.73 %1 be >= continuous current *1.25. All string terminations are Inverter: 1 31.30 I 10 ID AWG 0E1 at 240V rated at 90' C. Total: modules Total Inv Pwr ,e,4L 4 „ PTC Vdrop = (31.30 A * 20 ft * 0.00078 Ohms) / 240 V 0.20% Photovoltaic Module Electrical Specifications: Total STCr , 56QQ Combined' 31.25 I 0 ID AWG 00 at 240V 2. OCP Sizing Der Art 690.8(6)(1) Voc= 21V deg F deg C Vdrop = (31.25 A * 0 ft * 0.00078 Ohms) / 240 V 0.00% a. Round up to next size per Art 240.4(6) Vmp= 26.6 V Record Low Temp: 8 Total voltage drop in AC conductors = 0.20% P � P� 9 p Isc= ° '1 ; 8.58 A Max Average Hi Temp: 80 Total voltage drop in AC and DC conductors = 0.94% Imp = 7.9 A Record Hi Temp: 106 3, Conductor Sizing per Art 690.8(B)(1) Tvoc= 0 V /deg C a. Conductor must have 30 deg. ampacity >= 125% of continuous Tisc= '"'' , "-.-r , mA /deg C current per Art 215.2(A)(1). String Type A and 2 Combined Strings Type A Voc Correction Method Trot di Branch Circuit Type A 12 modules per series string Pronius IG Plus 7.5 -1 (240) a M 1 3'strings per branch 1 -way wire length: 50 ft b. Conductor must have (after corrections for conditions of use) 12'kyocera KD21OGX -LPU Inverter Min Vdc Input: Vdc ' >= continuous current per Table 310.16. Voc= ( 398.4 V Min Vmp at Max Temp: le, Vdc Voc= V Vmp= )' 319.2 V Max Voc at Min Temp: _. , ;Vdc IVmp= V c. Evaluate conductor temperature at terminations per Art Isc = 8.58 A Inverter Max Vdc Input: Vdc Isc= A 110.14(C). Ampacity of wire derated for conditions of Imp= (' 7.9 A Max String Size: Imp= A termination must be >= continuous current 1.25. All branch Icont= 3. 10.73 A Art 690.8(A)(1) 1 -way wire length: 50 ft Icont= A Art 690.8(A)(1) terminations are rated at 75' C min. 1.a Try C AWG 10 USE- 2/RHW -2 at 90 deg C: Table 310.16 3.a Try THWN -2 at 90 deg C: Table 310.16 1 ' Icont * 1.25 = (Amps) Icont * 1.25 = (Amps) 13.4 3r „ F 30 deg C ampacity = 4. OCP Sizing. 30 deg C ampacity = I 3.b Icont= (Amps) a. Round up to next size per Art 240.4(B) 1.b Icont= (Amps) , 10.73 Start ampacity Start ampacity 40 Temp. derate ( % =F) 5. Conductor Sizing Der Art 690.8(6)(1) Temperature derate ( % =F) 0.58 Cndt. fill derate ( %_ #) a. Conductor must have 30 deg. ampacity >= 125% of continuous Conduit fill derate ( % = #) 1 Derated ampacity I current per Art 215.2(A)(1). Derated ampacity 23.20 I Term 1 Term 2 Temp table b. Conductor must have (after corrections for conditions of use) 1.c Icont *1.25= (Amps) 13.41 3.c Icont *1.25= (Amps) >= continuous current per Table 310.16. Ampacity r 40 Ampacity c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of I I termination must be >= continuous current *1.25. All inverter 2 Icont * 1.25 = (Amps) 13.41 3.d OCP size = output terminations are rated at 75' C. OCP size = 15 Combined Inverter Output Service Voltage= 240 Volts Inverter Type A Output Total Inverter Power= Watts 1 -way wire length: 0 ft 1 -way wire length: 10 ft Icont = # of inverters *max inverter current Art 690.8(A)(1) 6. OCP Sizing 'ronius IG Plus 7.5 -1 (240) a. Round up to next size per Art 240.4(8) Icont= 31.30 A Art 690.8(A)(1) Icont = (Amps) 4 Icont *1.25 = (Amps) 39.13 A Art 690.8(6)(1) 6 Icont *1.25 = (Amps) l A Art 690.8(6)(1) 7 Conductor Sizing per Art 690.8(8)(1) OCP size = ry e A Art. 240.6(A) OCP size = A Art. 240.6(A) a. Conductor must have 30 deg. ampacity >= 125% of continuous 5.a Try THWN -2 at 90 deg C: Table 310.16 7.a Try THWN -2 at 90 deg C: Table 310.16 current per Art 215.2(A)(1). Icont * 1.25 = (Amps) Icont * 1.25 = (Amps) 30 deg C ampacity = I. 30 deg C ampacity = I b. Conductor must have (after corrections for conditions of use) 5.b Icont= (Amps) 1.30 7.b Icont= (Amps) ; .rte ; ° ! >= continuous current per Table 310.16. Start ampacity Start ampacity Temperature derate ( % =F) Temp. derate ( % =F) c. Evaluate conductor temperature at terminations per Art Conduit fill derate ( % = #) Cndt. fill derate ( %_ #) 110.14(C). Ampacity of wire derated for conditions of Derated ampacity I Derated ampacity I termination must be >= continuous current *1.25. All inverter 5.c Icont *1.25= (Amps) , 9.13, 7.c Icont *1.25= (Amps) r 9;.06 output terminations are rated at 75' C min. Ampacity Ampacity I PV ` �114 I MODULES: CUSTOMER: DESCRIP D I I ON: ' O • PROJECT MANAGER: 001.1C C • OUP: CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT (36) KYOCERA # KD210GX -LPU JOHNSON, GARY AND BARBARA SIBLEY JOHNSON RESIDENCE REST BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR 7.56 kW ROOF MOUNT PV SYSTEM i ty DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MWN11NG SYSS1134: CUSTOMER ADDRESS TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SOLARCITY CANOPY C AND RAIL 11815 SW WILDWOOD ST TIGARD, OR 97224 JOB NUMBtIt 393 Vintage Park Drive, Suite 140 Foster city, CA 94404 DATE: PPA SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT INVLRTtR: JB- 972045 00 T:(650) 638 -1028 I F:(650) 638 -1029 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. (1) FRONIUS # IG PLUS 7.5 (240) 5033410226 REV: (888)- soy -CITY (765-2489) I www•solarcity.com L Conductor Sizing per Art 690.$03)(11 Module: 36 Kyocera KD21OGX -LPU 189.8 Inv Pwr W PTC Voltage Drop Calculations Version 5_6.4 a. Conductor must have 30 deg. ampacity >= 125% of continuous current per Art 215.2(A)(1). Inverter 1: 1 Fronius IG Plus 7.5 -1 (240) 95.5% 7,500 6,525 Vdrop = (Imp) * (2 * Length) * (Resistance) / (Vmp) Module: Imp (A) Max. Length (ft) Wire b. Conductor must hove (after corrections for conditions of use) Inverter 2: String: 7.9 50 C AWG 1C at Max A e Hi: 80 deg F >= continuous current per Table 310.16. Module: Vdrop = (7.90 A * 100 It * 0.00124 Ohms) / 292 V = 0.34% Inverter 3: Branch: I 23.7 I 50 IE AWG 0E1 at Max Ave Hi: 80 deg F c. Evaluate conductor temperature at terminations per 110.14(C). Module: .v Vdrop = (23.70 A * 100 ft * 0.00049 Ohms) / 292 V = 0.40% Ampacity of wire derated for conditions of termination must Inverter 4: Total voltage drop in DC conductors = 10.73 %I be >= continuous current *1.25. All string terminations are Inverter: I 31.30 I 10 ID AWG 0 at 240V rated at 90' C. Total: modules Total Inv Pwr , ,." 7,500 6,525 PTC Vdrop = (31.30 A 20 ft * 0.00078 Ohms) / 240 V 0.20% 2. OCP Sizin per Art 690.8 B (1 Photovoltaic Module Electrical Specifications: Total STC' 7,560 Combined 31.25 I 0 ID AWG 011 at 240V g P O ) Voc= , °"" 3. ' deg F deg C Vdrop = (31.25 A * 0 ft * 0.00078 Ohms) / 240 V 0.00% a. Round up to next size per Art 240.4(B) Vmp= 26.6 V Record Low Temp: 8' - 13.333 Total voltage drop in AC conductors = 0.20% Isc= 8.58 A Max Average Hi Temp: 80 6.6667 Total voltage drop in AC and DC conductors = 0.94% Imp= , 7.9 A Record Hi Temp: 106 41 3. Conductor Sizing per Art 690.8(B)(1) Tvoc= ' -0.12 V /deg C a. Conductor must have 30 deg. ampacity >= 125% of continuous Tisc= m A mA/deg C current per Art 215.2(A)(1). String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc da Branch Circuit Type A ' 12 modules per series string ' Fronius IG Plus 7.5 -1 (240) 3'strings per branch 1 -way wire length: 50 ft b. Conductor must have (after corrections for conditions of use) 12 Kyocera KD210GX -LPU Inverter Min Vdc Input: 1 230 Vdc ' >= continuous current per Table 310,16. Voc= 398.4 V Min Vmp at Max Temp: 246 Vdc Voc= V Vmp= 319.2 V Max Voc at Min Temp 454 Vdc Vmp= V c. Evaluate conductor temperature at terminations per Art Isc= 8.58 A Inverter Max Vdc Input I 600, Vdc Isc= A 110.14(C). Ampacity of wire derated for conditions of Imp= ;; 7.9 A Max Stnn Size: 15a Imp= A termination must be >= continuous current *1.25. All branch Icont= "10.73 A Art 1-way 690.8(A)(1) 1 wire length: 50 ft Icont= A Art 690.8 A O( 1) terminations are rated at 75' C min. 1.a Try C AWG 10 USE- 2/RHW -2 at 90 deg C: Table 310.16 3.a Try THWN -2 at 90 deg C: Table 310.16 ' Icont * 1.25 = (Amps) Icont * 1.25 = (Amps) r 13 ° "°` 30 deg C ampacity = I 4. OCP Sizing 30 deg C ampacity = 40 I 3.b lcont= (Amps) a. Round up to next size per Art 240.4(B) 1.b Icont= (Amps) 10.73 Start ampacity Start ampacity 40 Temp. derate ( % =F) 5. Conductor Sizing per Art 690.8(B)(1) Temperature derate ( % =F) 0.58 Cndt. fill derate ( %_ #) a. Conductor must have 30 deg. ampacity >= 125% of continuous Conduit fill derate ( % = #) 1 Derated ampacity I current per Art 215.2(A)(1). Derated ampacity 23.20 I Term 1 Term 2 Temp table b. Conductor must have (after corrections for conditions of use) 1.c Icont *1.25= (Amps) 13.41 3.c Icont *1.25= (Amps) >= continuous current per Table 310.16. Ampacity a„ Ampacity c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of I I termination must be >= continuous current *1.25. All inverter 2 Icont * 1.25 = (Amps) 3.d OCP size = output terminations are rated at 75' C. OCP size = Combined Inverter Output Service Voltage= 240 Volts Inverter Type A Output Total Inverter Power= Watts 1 -way wire length: 0 ft trs tG1 s 7. 'i 1 -way wire length: 10 ft Icont = # of inverters *max inverter current Art 690.8(A)(1) 6. OCP Sizing 'fr a. Round up to next size per Art 240.4(B) lcont= A Art 690.8(A)(1) Icont = (Amps) 4 Icont *1.25 = (Amps) - " §i 39,13,A Art 690.8(B)(1) 6 Icont *1.25 = (Amps) , ;; ;: .9.,(116,A Art 690.8(B)(1) 7. Conductor Sizing per Art 690.8(B)(1) OCP size = A Art. 240.6(A) OCP size = A Art. 240.6(A) a. Conductor must have 30 deg. ampacity >= 125% of continuous 5.a Try 11WN -2 at 90 deg C: Table 310.16 7.a Try THWN -2 at 90 deg C: Table 310.16 current per Art 215.2(A)(1). Icont * 1.25 = (Amps) Icont * 1.25 = (Amps) 30 deg C ampacity = I 30 deg C ampacity = I b. Conductor must have (after corrections for conditions of use) 5.b Icont= (Amps) 30; 7.b lcont= (Amps) > ° ,+ >= continuous current per Table 310.16. Start ampacity Start ampacity Temperature derate ( % =F) Temp. derate ( % =F) c. Evaluate conductor temperature at terminations per Art Conduit fill derate ( % = #) Cndt. fill derate ( %_ #) 110.14(C). Ampacity of wire derated for conditions of Derated ampacity I Derated ampacity I termination must be >= continuous current*1.25. All inverter . Icont *1.25= (Amps) 39.13 7.c Icont *1.25= (Amps) % • 06 output terminations are rated at 75' C min. Ampacity Ampacity I I 6 � MawLL CUSTOMER: DESCRIPnON: P / t . PRO,ECT MANAGER: ODUCT P: CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT RESI BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR (36) KYOCERA # KD210GX -LPU JOHNSON GARY AND BARBARA SIBLEY JOHNSON RESIDENCE / 7.56 kW ROOF MOUNT PV SYSTEM i DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE /AWING N1ING SYSIEM: CUSIGMER ADDRESS t TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SOLARCITY CANOPY C AND RAIL 11815 SW WILDWOOD ST 1D6 NUMBER: 393 Vintage Park Drive, Suite 140 DATE: PPA SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT INVERTER: nGARD, OR 97224 Foster City, CA 94404 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. ( FRONIUS # IG PLUS 7.5 (240) 5033410226 JB- 972045 00 REV: (888)-50L-CITY (765.2489) (Iss www.solarcity.com PV MODULE ,0 r KD21 OGX -LPU �° KY O C E Ra ELECTRICAL CHARACTERISTICS rc� e y6 0 O Current- Voltage characteristics of Photovoltaic Current - Voltage characteristics of Photovoltaic � o Module KD210GX -LPU at various cell temperatures Module KD2I0GX -LPUat various irradiance levels te ta 21 a WATT A sa pioneer CUTTING EDGE TECHNOLOGY := = with 35 years in solar, Kyocera demonstrates __nMEll ___1_ leadershi p in the development of solar energy products. '" Kyocera•s Kaizen Philosophy, commitment to continuous s == s . M.= � V_ � '_ HIGH EFFICIENCY MULTICRYSTAL PHOTOVOLTAIC MODULE improvement, is shown by repeatedly achieving world record ! -_`_ cell efficiencies. ! .__M"I' I • !\It ___` I i , ..dill• , _,1 `ME- Kyocera Quality Built In , ,s. I - New frame technology allows for end mounting with 2400 Pa 2 , ___tI. r �E,�'i� (50 psf) or wind speeds of 130 mph (ASTM E1830) and •__-1,11 :1===.1t IN 4 traditional mounting under 5400 Pa (113 psf) to support o le w w e w w w increased snow load °"°'" '"0"iN1 I ' „ - UV stabilized, aesthetically pleasing black anodized frame �? - Supported by major mounting structure manufacturers SPECIFICATION' Easily accessible grounding points on all four corners for I . � ' fast installation I Ph ysical Specifications ur:•.0�) i , "" "` - Proven junction box technology - Quality locking plug -in connectors to provide safe & quick 1214 40 •°•U••^) 4 1 A ' > connections 70 g flaw) Kyocera manufactures and assembles solar cells and modules 11.1111.1111111 4 -1 ''1 4 1{{ at its own worldwide production sites using a true vertical .....■j N�I integration process. This superior approach gives Kyocera ICD210iX —LPU complete control over every step of the manufacturing process. =MEM.; .� ' t+ producing modules with the industry's tightest power tolerance, ..... : _ _ H , NEC 2008 Compliant promising high quality and efficiency. i■.■■■■ UL 1703, Class C Superior Built -In Quality ■■■ IEC 61215 - Proven Superior Field Performance 11111111.111. H r Tight Power Tolerance t6c 13 - 25 Year Warranty ■■■.■., - - 5 Year Workmanship Warranty ( +;i,,,rnr,,, 0(0 as.) IN Specifications ■ Bedded Wawa Wes WNW VWCeeirssPIIIT ■M e _. , Warm Power P l 210W(46IJ -reef Weber per Module 104 - - - Mcdn anPow*beeWM O 23eV 9 : ; a Madneen Pow Current O W 7.10A • Width awedelelee r � � r R � � ea � ` r•#4e 's vre .. Open Omit t* 312V IAr X Wldh X Depth WeM�1i1 r . ° ` F' ':" ,mss L .r .$i. t . ow tot rrar rrr " fi e �`,w.tlr Short Clot CunrttlW 3.1eA w.iq,t 1 .7EeJ ' `,�'.`? >S�`oi rlr w rrr a� Ml 10 Ce hr f �� r ' r 4 7 ; % — wrtg��� ;,�,�"�Irr" ,1r ! l- Tempe Caelided —1.20)(10 Wt i aw_ -v � ,,,. ..%' - ` ' • • or A „:„......„...4,,,, _� ss's �' y — Tempemlure Coeacira ti.ltix1O4Alt ��rt.ese.swgwwlrYlb. . a A . ,..,,,,,,...-4.44,- ° � �es5/ . n 11/ 41 vo ".• aer oo:re..-eerene_r-reopwot s -•.r 4 yr 7-77,-; ' d _ ./ < . r > - 1-,,. / i 411, 111n tM g h X WIdIh X Dep Ut ' ° _ - � _ MledmunPays4T d 1 411/ .aK r r , .. / M eximur n Power ?$1V ^ -d i ` — f �� MEW= Paver Current 3110V 'Operatin g — --KC r ° /� r _ e, - sonat a Terriperun a rne u a� Mrm"'" F'" �sA ,, ( 2A �,'� , - r "T ?‚a ,�..rra.wo.*�.r.+:oee - rn.wae..nre.�+mwrp.+.w / iso 1001 end 110 Corned and aMpewed : 1; i : rig KHOC. ER2 . - - , �_ .�r 223-96@0toll fres 80042&2929 fax SOLAR y ti ' r i,1 h _F,,, ~ f� 7 -� �� ?` ! ' _ l P V + t, ►ti 7 . s a MODULES: CUSTOMER: DESCRIPTION: P.m i PROJECT MANAGER: P OD c OU : CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT (36) KYOCERA # KD210GX -LPU JOHNSON, GARY AND BARBARA SIBLEY JOHNSON RESIDENCE � REST BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR 7.56 kW ROOF MOUNT PV SYSTEM S O DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MOUNTING SYSTEM: CUSTOMER ADDRESS S OLARCITY CANOPY C AND RAIL 11815 SW WILDWOOD ST JOB NUMBER 393 Vintage Park Drive, Suite 140 TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE TIGARD, OR 97224 Foster City, CA 94404 DATE: PPA SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT INVER IER: JB- 972045 00 T:(650) 638 -1028 I F:(650) 6384029 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. (1) FRONIUS # IG PLUS 7.5 (240) 5033410226 REV: (888)•SOL -CITY (765 -2489) 1 www.solarcity.com PV MODULE � <��,��� �( r (� KD210GX -LPU cli ,:::...,41,1110.2. KY L. E 11a ELECTRICAL CHARACTERISTICS Current - Voltage characteristics of Photovoltaic Current - Voltage characteristics of Photovoltaic Module KD210GX -LPU al various cell temperatures Module KD210GX -LPU at various irradiance levels 210 WATT CUTTING EDGE TECHNOLOGY Asa pioneer ° "" ° ""f " _„" �TM �� • with 35 years in solar, Kyocera demonstrates - HIGH EFFICIENCY MULTICRYSTAL leadership in the development of solar energy products. $11.11111.1r= $11.11111.1r= ■'' +rr I Kyocera's Kaizen Philosophy, commitment to continuous • PHOTOVOLTAIC MODULE improvement, is shown by repeatedly achieving world record 3 __ M a • -ere, I cell efficiencies. . == =Ill 1 • es.rr It I Kyocera Quality Built In: __M5UUR . it New frame technology allows for end mounting with 2400 Pa __"M"• ' ( - (50 paf) or wind speeds of 130 mph (ASTM E1830) and ' 1111.M11111111. • • traditional mounting under 5400 Pa (113 psf) to support • to >n s • ,. e s o " - increased snow load � M w0,02 M UV stabilized, aesthetically pleasing black anodized frame - Supported by major mounting structure manufacturers SPECIFICATIONS - r- - - Easily accessible grounding points on all four corners for i 1 fast installation • Physical Specifications um•..Jt.) ■ a }. - Proven junction box technology - Quality locking plug -in connectors to provide safe & quick tes sera wpa.enl ueere0 connections ' a.ae 7 "I ' Mr) Kyocera manufactures and assembles solar cells and modules I fi- at its own worldwide production sites using a true vertical T ' KD210Gx -LPU integration process. This superior approach gives Kyocera >i complete control over every step of the manufacturing process. producing modules with the industry's tightest power tolerance, t +++ $ NEC 2008 Compliant promising high quality and efficiency. I H UL 170., Class C - Superior Built -In Quality i IEC61215 - Proven Superior Field Performance ' l i , Tight Power Tolerance Celt - 25 Year Warranty i - 5 Year Workmanship Warranty . ,r.ro • Specifications • ■ar eal pmenom. .i r $WN..ITmQamillarCsrc3 ■G8. _' - Mincer= Minc Pawn (Peed 210W (+e r /-ra9 Number per Module 1 54 �."1, N X Depth maximum Pow 28.1IV ma r A " , « «t +- .% * J r-,t= rx' POW Girrint hgpl 7.1W1 ■ t1.deY Orn�Ml.1p x _ . . - a te„ ° ca. s . : . _ • „ , , ` 1 /- . r € �r Open Circuit Vdps NW 331V Length X Wirth X Depth tY1rBl Ma81 t s '" r. wl ;7 * r r /kit �7j .+"e'° ShM CIaRCaraml ae8.5104 W 1 / ./" � ,'s" ;", A . V- . .. 2t '.t•s 1� S ` 7, . . " ` ty re ilMMndtac OM Cable ° °"° $IINe "i�.�it'� 4 ' i t ' y � . . ! r � Temperature faoelident d' f,1bx10• A!t • Jumada lax Ger.chrtatics $ ' ,r , rp t' ,r+ p }, ` 4! f , e a .. , erc:ir�+- rt- 'I— �r�nw..re Webb • " -'"` ' ° .t om , . ! � _, e - lair - ■ �flel I_1__M1. M S101ah�. HOGS Nei a reed. P� ,r '` • - maximum t1W _ ! -y *1 r } r ~ Maximum P v fusee) 29IV Mcdn.rn Paver Clrlcrlt ir 692A • otbm , . ' y ' f ' / r - > - Open Grail VaR.p. tVai 90 'CP• m9 Ammar, �0> ^ 80� Y b �' a '� l s r 8hortCiroeA rent � : B. A r�anun 15� / rr ,. �. , . ,, t' ., y � i .aerla.r 1:23~22 u eat 'rhi.enq.an.eW mall Mil" I . r ' y y ,. f 7--...77,/ ..f.: - . - ' 190 e001 end 19014401 osrtifimd and RaOabr.d ' , . i . 1 / ' r KICERa wYtlgooarasdlae ovm SOLAR by KYOCERA tall free 23x3 fax � . P V „11(14 7 -4..„ s ■ • MODULES: CUSTOMER: DESCRIPTION: ' � ►� PROJECT ANA GER : CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT REST BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR (36) KYOCERA # KD210GX -LPU JOHNSON GARY AND BARBARA SIBLEY JOHNSON RESIDENCE ' M RODU T P M OUNTING SYSIEA: CUSTOMER ADORESS 7.56 kW ROOF MOUNT PV SYSTEM it DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE S OLARCITY CANOPY C AND RAIL 11815 SW WILDWOOD ST TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE TIGARD, OR 97224 JOB NUMBER: 393 Vintage Park Drive, Suite 140 DATE: PPA SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT INVERTER: R: 00 Paeter28 I F CA :( S444a 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. (1) FRONIUS # IG PLUS 7.5 (240) 5033410226 REV: T:( 638-1028 s5o) 638 -toes (888) -SOL -CITY -CITY (765 -2489) I www.solarcity.com INVERTER INPUT DATA Fronius IG Plus 3 0 1 s r 3.8-1 ur 5.0-1 us 60 -1 ur 7.5-1.. 10.0-1 uw 174 -1 uw 11.43 12.0 -3 m Recommended PV -Power (Wp) 2500 -3450 3200-4400 4250 -5750 5100 -6900 8330 -8600 8500 -11500 9700 -13100 9700 -13100 10200 -13800 F MF'PT- Voltage Range 290 ... 500 V 6 DC Startup Voltage 245 V Max. Input Votage lat 1000 Wlmr --- ___ - -- e F. 14 oirq ,n °parr circuit cceranorq 800 V E Nominal lnpUt Citent 8.3A 10.5A 13.8A 16.8A 20.7A 27.6A 31.4A 31.4 33.1A Max. usable Input Current t4.0 A its* 23A A 28.1 A 351 A 46.7 A 53.3A. 53.3 A 56. t A is Admissible conductor size (DC) Nn 14 - 6 AWG Number of DC fnpuf Terminals 6 Max. Current per DC Input Terminal 20 A; Bus bar available for higher input currents OUTPUT DATA Fronius IG Plus 3.0 -1 ur 3.8 -t mi 5.0-1 uw 6.0 -t ua 7.5 -1 uxi 10.0 -1 ua 11.4 -1 uw 11.4 -3 uro, 12.0 -3 8 Nominal output power (P,, 3000 W 3800 W 5000 W 6000 W 7500 W 9995 W 11400 W I 11400 W 12000 W Max. continuous output power i 104 (40 ° C) 200 V /240 V i 277 V 3000W 3800W 5000W 6000W 7500W 9995W 11400W 11400W 12000W Nominal AC output voltage 208V/240V/277V 208V/ 240V 277V g Opaaling AC voltage range 208V 183- 229V(- 12 /al° %) (default) 240V 211 - 264V(- 127410 %) 271V 244- 305V(- 12/410 %) Max. continuous 208 V 14.4 A 18.9A 24.0A 28.8 A 96.1 A 48.1 A 548 A 31.6 A` n.a. output anent 240 12.5 15.8A 20.8A 25.OA 31.3A 41.7A 47.5A 2 /A A' n.a. ^s 277 10.8A 13.7A 18.1A 213A 27.1A 36.1A 4t.2A n.a. 14AA' Admissible conductor sir: (AC) No. 14 - 4 AWG Max. continuous utility back feed current 0 A Nominal output frequency 60 Fh. Operating frequency range 59.3 - 50.5 NZ 1 Total harmonic distortion <3 % Power factor 1 GENERAL DATA Pennies IG P194 I 3.0-1 ua , I 3.8 -1 I 5.0-1 urns 6.0-1 i 7.5-1.., L10.0 -1 u ,, L 11.4-1 ra „ I 11.4 -3 emu 1 12.0 -3 z ,, Max. Efficiency -. .. 96.2 % CEC Efficiency 288 V 95.0 % 95.0 % 95.5 % 95.5 % 95.0 % 950 % 95.5 % I 950 % n.a. E 240 96.5% 95.5% 95.5% 96.0% 95.5% 95.5% 96.0% 98.5% na _ 277 V 95.5 % 95.5 % 98.0 % 96.0 % 96.0 % 966 % 060% n a- 966 % Consumption in standby (night) < 1 W Consumption during operation 8 W l 15 W I 22 W • Cooling Cannoned traced ventilation, variable tan speed Enclosure Type NEMA 3R e Unit Dimensions(Wx11301 17-ix 248 x9.6 in. 17.1x 38.4 a 9.6 in. 17.1 x 48.1x 9.6 in. - Power 81=819e10it 31 cr. (14 it)) 57 IDs. (26 kg) 82 lbs. (37 kg) Wiring Comps' tment Weight 24 bs. (11 kg) 28 lbs. (12 kg) 26 lbs. (12 kg) _ Admissible ambient operating temperature -4 ... 122°F ( -20 ... 450 °C) Compliance I UL 1741 -2005. [EE 1547 -2003. IEEE 1547.1. ANSI/IEEE C62.41, FCC Part 15 A6 B, NEC Article 890, C22. 2 No. 107.1 -01 (Sept. 2001) PROTECTION € V DEVICES Fronius IG Plus 3.0 -1 sly 3.8 -1 us 5.0 -1 uw 6.0 -1 va 7.5 -1 aw 10.0 -1 ues 11.4 -1 up I 11.4 -3 sa. 12.0 -3 e,,,, Ground fault protection Internal GI- UI (Ground Fault Detector /Interrupter): in accordance with Ut. 1741 -2005 and NEC Art. 690 fi DC revwse polarity protection Internal diode (standing protection Internal; in accordance with UL 1741 -2005, IEEE 1547 -2003 and NEC F Over temperature Output power derailing / active cooling -A ' per Phase Grunius F Fronius USA LLC Solar Electronic Division 10421 Citation Drive. Suite 1100, Brighton, Michigan, 48116 E -Mail: pv- usfronius.com www.fronius- usa.com g PV `��I4 8 •41- CfODULES: CUSTOMER: DESCRIPTION: P , i,, I • PROJECT MANAGER: ' P GROUP: CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT RESI BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR (36) KYOCERA # KD210GX -LPU JOHNSON, GARY AND BARBARA SIBLEY JOHNSON RESIDENCE MOU M OUNTING SYSTEIA: CUSTOMER ADDRESS S OLARCITY CANOPY C AND RAIL CUSTOMER 7.56 kW ROOF MOUNT PV SYSTEM t DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE SW WILDWOOD ST TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE TIGARD, OR 97224 JOB NUMBER: 393 Vintage Park Drive, Suite 140 SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT Foster City, CA 94404 DATE: A INVERTER: 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. (1) FRONIUS # IC PLUS 7.5 (240 5033410226 JB- 972045 00 REV: T: -2 F:(650)638 -1029 (888) -SOL -CITY (765 -2489) I www.solarcity.com INVERTER INPUT DATA Frnnius IG Plus I 3.0-1 1 3.8-1.. I 5.0-1 w I 6.0 -1 7.6 -1 0 ., 10.0 -1 .. 11.4 -1 11.4 -3 12.0 -3 xyr Recommended PV -Power (Wp) 2500-3450 3200-4400 1 4250 -5750 5100.6900 1 6350.88600 8500 - 115011 9700.43100 f 9700 -13100 1 10200 - 13800 ,r MPPT - Voltage Range 230 ... 500 V DC Startup Voltage 245 V Max. Input Voltage tat 1000 W /m' u °F ( -10 - C) In open circuit operation) 600 V E Nominal Input Curets 8.3A 10.5A 13.8A 16.8A 20.7A 27.6A 31.4A 31.4A 33.1# Max. usable Input Current 14.0 A 17.8 A 234 A 28.1 A 35.1 A 461 A 533 A 3.3.3 A 56.1 A $ Admissible conductor size (DC) No. 14 - 6 AWG $ Number of DC Input Terminals 8s Max. Qxreni per DC Input Terminal 20 A; Bus bar available for higher input currents P. OUTPUT DATA Fronius IG Plc 3.0 -1 „„, 3.8 -1 5.0 -1 , 6.0 -1 „ 7.5-1 „,„ 10.0-1 u , r 114-1 „,„ 1 11.4 -3 0+. 12.0-3. 8 Nominal ouVut power (P,, 3000 W 3800 W 5000 W 6000 W 7500 W 0995 W 11400 W 1 11400 W 12000 W G Max. continuous output power 104'F (40 °C) 208 V /240 V / 277 V 3000W 3800W 5000W 8000W 7500W 0995W 11400W 11400W 12000 W Nominal AC output voltage 208V/240V/277V 208V/240V 277V € Operating AC cottage range 208 V 183 - 229 V ( -12 I +10 %) (default) 240 V 2t1 - 284 V (- 121 +t0 %) 277 V 244 -3051/ ( -12 / +10 %) Max. continuous 208V 14.4A 18.3A 24.0A 28.8A 38.1A 48.1A 543A 31.6 A` n.a. e output current 240V 12.5A 15.8A 20,8A 25.6A 313A 41.7A 47.5A 274 A' be. i 277 V 10.8A 13.7 A 18.1 A 21.7 A 27.1 A 36.1A 41.2 A n.9. 144A Admissible conductor slze (AC) No 14 - 4 AWG s Max. continuous utility beck feed arrant 0 A i" Nominal output frequency 60 Ftz 1 Operating frequency range 59.3 - 60.5 Hz 2 Total harmonic distortion <3 % Power factor 1 GENERAL DATA Fronius IG Plus [ a.o-1 as I 3.8 -1,r, I 5.0 - j 6.0.1 ss J 7.5-1 era J 10.0 -1 U 1 11.4 -1 0 ., 't 11.43 00 . 1 12.0_3 i Max. Efficiency 96.2 % CEC Efficiency 208 V 95.0 % 95.0 % 95.5% I 95.5 % 95.0 % 95.0 % 95.5 % I 95.0 % n.a. 8 240 V 95.5 % 05.5 % 95.5 % 96.0 % 415.5 % 95.5 % 98.0 % 95.5 % n.a. 277 V 95.5 % 95.5 % 66.0 % 96.0 % 96.0 % 96.0 % 96.0 % I n.a. 96.0 % c Consumption in standby (right) < 1W {' Consumption during operation I OW I 15 W I 22 W t' Coding Cannoned traced ventilation, variable fan speed Enclosure Type NEMA 3R P !knit Dimensions (W x H x01 17.1x 24.6x 9.6 in. 17.1x 38.4 x 9.6 in. 17.1x 48.1x 9.6 in. Power Stack Weight 31 Ds. (141g) 57 lbs. (26 kg) 82 84.437 kg) - Wirig Compartment Weight 24 bs. (11 kg) 26 lbs. (12 kg) 20 bs. (12 kg) 2. Admissible ambient venting temperature -4 .. 122°F ( -20 ... u30°C) Il Compliance I UL 1741 -2005, EEE 1547 -2003 IEEE 1547.1. ANSVIEEE C6241. FCC Part 15 At) D, NEC Arhcle 690,C.22. 2 No. 107.1 -01 (Sept. 20011 PROTECTION 1 #, DEVICES Froniw IG Rua 3.0 -1 ve 3.8 -1 uw 5.0-1 us 6.0 -1 V r 7.54 10.0-1 ua 11.4 4 .. 11.4 -3 coo 12.0 -3 E. Ground fault protection Internal Lk UI (Ground Fault Detector /interrupter); in accordance with UL 1741 -2005 and NEC Art. 890 - ..4 DC rename polarity protection Internal diode Wending protection Internal; in accordance with UL 1/41-2005, IEEE 1547 -2003 and NEC E Over temps ahue Output power denoting / active coding ' per Phase F110171 K Fronius USA LLC Solar Electronic Division < 10421 Citation Drive. Suite 1100, Brighton. Michigan, 48116 E -Mail: pv- usciyfronius.com g www.froniu5 usa.com 8 8 �MOD: PROJECT MANAGER: PODCT GROUP: COFIDENTIAL - KYOCERA # KD210GX - LPU JOHNSON, GARY AND BARBARA SIBLEY BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR 756 kW ROOF MOUNT PV SYSTEM i DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MOUNTING SYSTEM: CUSTOMER ADDRESS: S OLARCITY C ANOPY C AND RAIL 11815 SW WILDWOOD ST JOB NUMBER: 393 Vintage Park Drive, Suite 140 TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE TIGARD, OR 97224 DATE: PPA INVE FER: Foster City, CA 94404 SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITH (1) F RONIUS # IG PLUS 7.5 (240) JB- 972045 00 T(650)638 -1028 1 4:(650)638 -1029 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. 5033410226 REV: (888) -SOL -CITY (765 -2489) I www.solarcity.com MOUNTING HARDWARE 11111 i pritil--EI �` I` APPROVED INSTALLATION METHOD • Roots (brackets) are to be mounted no further RESIDENTIAL SOLAR MOUNTING SYSTEM than 8 "apart. • Rafters must be located. Pilot holes must be drilled into Canopy is the strong, safe, waterproof mounting system for structurally attaching the center of rafters 1 28 1 t 2.5 i I solar panels to composition shingle and wood shake roofs. A715 grade 50 high • Shingle course immediately above penetration shall be cut 2 33 1 3 ; strength structural steel with durable corrosion resistant coating provides more using provided template to accommodate flashing. 3 43 2 2.5 I strength than aluminum and better corrosion resistance than stainless steel. Bracket- • Local wind conditions, exposure, roof angle, and position a 50 1 - 2 I 3 style attachment allows for shingle flashings to completely cover penetrations, of array on roof will determine design wind pressure. This chart assumes 15 w. n. Of fewer per panel providing excellent long -term waterproofing. Standard installation of Canopy applies when design wind and minimum 1.5 penetrations per panel pressures are found to be 28psf or lower and requires one •psr values In be calculated accadingm ASLE 7 - 05. 21 -inch lag bolt in the primary position. For all other cases, • Precision engineered bracket geometry provides stiffest see chart to right. uplift resistance of any mounting bracket. Rated to rr00 lbs. • • Flashing is to be inserted under course of shingles above • A715 grade 50 high strength structural steel provides - penetration and pressed down over root until it snaps more strength than aluminum. / " - into place. J J1 • Pmven 75 year corrosion resistant hot-dip galvanized � • Rail is attached with rail licking clamp. V coating. Laboratory tests show canopy has better corrosion resistance than common stainless steel. ▪ Shingle -style flashing completely cs penetration, {smvkTng Flashing better long tens leak protection than neoprene cone fleshings. �� 0 Lags and Washers i I Root- Bracket II t' Shingle Flashing locks in place for best water proofing f' . 4. Root•Bracket installed i c 2 2x 5/16 lag bolts ( 5 I I ins Flashing installed i . ice -- 3 2x 5/16 flat washer e • ! { .......1„.L..........---7 I 6 Rail install - -� -:., �- -- ®: 1 ' _ . - <<,., ,. I 4 Canopy root precision engineered mounting bracket I; = I� „ Ir.•.�� T 8 - OC Max • �_ - �� - 1 -, - - � J �;� S R oof rafter S�_ 4 ®` ,' `� - -"` g Rail 1 ®_-. • S olarC i ty® 888 -SOL -CITY 1 888 - 765 -2489 I WWW.SOLARCITY.COM Pv �* t1!� 9 �" s ■ V AL1.0 S OLAROFr LIEIAILS: MODULES CUSTOMER DESCRIPTION: I ! ' /I If 1�� I PROJECT MANAGER: PRODUCT GROUP: CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT RESI BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR (36) KYOCERA # KD21OGX -LPU JOHNSON GARY AND BARBARA SIBLEY JOHNSON RESIDENCE 7.56 kW ROOF MOUNT PV SYSTEM DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MOBNIING SYSTEM: CUSTOMER ADDRESS: TP THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SOLARCITY CANOPY C AND RAIL 11815 SW , OR 97224 ST JOB NUMBER: 393 Vintage Park Drive, Suite 140 DATE: PPA INVE Foster City, CA 94404 SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITH OUT INVERIER: ( 1) FRONI # IG PLUS 7.5 1(2443) 503341022 3B-972045 00 REV: T:(6 5o) 638 -1028 I F:(650) 638 -1029 7/26/2010 THE WRITTEN PERMISSION OF SOLARCITY INC. (888) -SOL -CITY (765 -2489) I www.solarcity.com