Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
71 CITY OF TIGARD BUILDING PERMIT : COMMUNITY DEVELOPMENT Permit #: BUP2011 -00137 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 06/30/2011 . Parcel: 2S104CA03500 Jurisdiction: Tigard Site address: 13672 SW LAUREN LN Project: Hansen Subdivision: HILLSHIRE Lot: 35 Project Description: Installation of solar photovoltaic system. Contractor: JBC ROOFING Owner: HANSEN, JACK 12155 SW GRANT AVE STE B 13672 SW LAUREN LN TIGARD, OR 97223 TIGARD, OR 97223 PHONE: 503 - 968 -1235 PHONE: 503 - 524 -6580 FAX: 503 - 603 -9967 FEES Specifics: Description Date Amount Type of Use: SF Solar Photovoltaic System 06/28/2011 $180.00 Class of Work: ALT 12% State Surcharge - Building 06/28/2011 $21.60 Dwelling Units: 0 Info Process /Archiving - Sm Sheet (up to 06/30/2011 $2.00 Stories: 0 Height: 0 ft 11x17) Bedrooms: 0 Bathrooms: 0 Value: $0 Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $203.60 Required: Required Items and Reports (Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done i a - 'th approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. TENTION: Oregon -w requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 01 -0010 through OAR 9 r 1 -0■90. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 0 1.800.332.2344. Rued By: ( / ,.. Permittee Signature: b. Call 503.639.4175 by 7:00 a.m. for the next available inspection . • . This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential RECEIVED FOR OFFICE USE ONLY Ill City of Tigard Receiv eiv ❑ ,/ :,...a g ' ''' Permit No.: l J J, • .....t 1 4 13125 SW Hall Blvd., Tigard, OR 9722311 IN 2.8 8011 Plan Review` Phone: 503.718.2439 Fax: 503.598.19 0� L Date /B : 0 ,4I _ Q' j. Other Permit: 00000 TIGARD �7 Inspection Line: 503.639.4175 Date Ready /By: 00000 Juris: ® See Page 2 for Internet: www.tigard - or.gov CITY OF 1IGARD Notified /Method: 00000 D UD Supplemental Information RIM DING DIVISION TYP OF Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ❑ New construction ❑ Demolition equipment, materials, labor, overhead, and the profit for the © Addition/alteration /replacement ❑ Other: ❑ ❑ ❑ ❑ ❑ work indicated on this application. 4x " °. Valuation: $00000 " ;` CATEGORY" OF C . .,, © 1- and 2- family dwelling ❑ Commercial /industrial Number of bedrooms: ❑ D ❑ ❑ Accessory building ❑ Multi - family Number of bathrooms: ❑ ❑ ❑ ❑ Master builder ❑ Other: ❑ ❑ 0 ❑ ❑ Total number of floors: ❑ ❑ ❑ ' JOB SITE' INFORMATION AND LOCATION 4 .3 W , , New dwelling area: 000 ❑ ❑ square feet Job site address: 13672 SW Lauren Ln Garage /carport area: ❑ 0 ❑ ❑ 0 square feet City /State /ZIP: Tigard /OR/97223 Covered porch area: 0 ❑ 0 0 ❑ square feet Suite/bldg. /apt. no.: ❑ ❑ ❑ ❑ ❑ Project name: Hansen Solar Deck area: ❑ ❑ ❑ 0 ❑ square feet Cross street/directions to job site: 99W to SW Walnut St. Turn RIGHT. LEFT on Other structure area: 00000 square feet SW 135th Ave. Turn RIGHT on Lauren Ln. 13672 Lauren Ln. on LEFT. REQUIRED " DATA: COMMERCIAL USE CHECKLIST 0 LID 0 0 Permit fees* are based on the value of the work performed. Subdivision: Hillshire Lot no.: 35 Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the Tax map /parcel no.: 251004CA03500 work indicated on this application. : °', t. ' ' DESCRIPTION OF WORK - Valuation: $00000 Installation of Roofing Integrated Photovoltaic system. PV will integrated into Existing building area: 00000 square feet shingled roof. New building area: ❑ ❑ 0 0 0 square feet 00000 Number of stories: 00 0 0 0 PROPERTY,'OWNER .. ; ❑ fTEN1kN't , , , ... Type of construction: ❑ ❑ ❑ 0 ❑ Name: Jack Hansen Occupancy groups: Address: 13672 SW Lauren Ln Existing: 00000 City /State /ZIP: Tigard /OR/97223 New: ❑ ❑ ❑ ❑ ❑ Phone (503)524 -6580 Fax (❑ 0 ❑ ❑ ❑) 0 ❑ ❑ 0 ❑ � � '.t BUILDING PER �` _ gi © APPLYUANT ° r : © CONTACT PERSON , ' (1'tease tajee setre le = Structural plan review fee (or deposit): ❑ 0 ❑ ❑ ❑ Business name: JBC Roofing Contact name: Brad Chisolm FLS plan review fee (if applicable): 0 ❑ ❑ ❑ ❑ Address: 12155 SW Granetve Suite B Total fees due upon application: 00000 City /State /ZIP: Tigard /OR/97223 Amount received: 00000 Phone: (503) 968 -1235 Fax:: (503) 603 -9967 PHOTOVOLTAIC SOLARRPANELSYSTEM TEES* ` H. E -mail: bradc @jbcroofing.com Commercial and residential prescriptive installation of roof -top mounted Photo Voltaic Solar Panel System. �t ,> CONTRACTORi . , Submit two (2) sets of roof plan with connection details Business name: JBC Roofing and fire department access, along with the 2010 Oregon Solar Installation Specialty Code checklist. Address: 12155 SW Grani Ave Suite B Permit Fee (includes plan review City /State /ZIP: Tigard /OR/97223 and administrative fees): $180.00 Phone: (503) 968 -1235 Fax: (503) 603 -9967 State surcharge (12% of permit fee): $21.60 CCB lie.: 98255 h Total fee due upon application: 201.60 This permit application expires if a permit is t obtain Authorized signature: .. within 180 days after it has been accepted as complete. * Fee methodology set by Tri- County Building Industry Print name: 0 ❑ 0 ❑ El Date: 00000 Service Board. REQUIRED DATA I=wAND2- FAMILYDWELLING' 1: \Building \Permits \BUP- RESPermitApp.doc 02/24/2011 440- 46I3T( I I /02/COM/WEB) City of Tigard RECEIVED '' Building Division • 13125 SW Hall Blvd, Tigard, OR 97223 JUN 2 8 2011 Phone: 503.718.2439 Fax: 503.598.1960 CITY OFTIGARD TI GARD Inspection Line: 503.639.4175 BUILDING DIVISION www.tigard- or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof - Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 13672 SW Lauren Ln City: Tigard Zip: 97223 Owner's Name: Jack Hansen Date: 6/24/11 Contractor's Name: JBC Roofing CCB #: 98255 Design Parameters of the Property /Structure If "Yes ", does not Flood Hazard Is the installatio j Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? N1 N OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure © Yes If "Yes ", qualifies for "C" or less? ❑ N the prescriptive path. Installations on detached Is the Ground Snow single /two - family Load 70 psf or less? dwelling /single /two- If "Yes ", qualifies for family townhomes © Yes the prescriptive path. and /or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If "Yes ", qualifies for © Yes the prescriptive path. above ❑ No 1 1:/ Building /Fortes /Photovoltaic- Checklist.docx Is the construction p Yes Type of material wood and doe If "Yes ", qualifies for the construction qualify ❑ No Construction the prescriptive path. as "conventional light frame" construction? Is the spacing 24 inches or less? Pre - engineered trusses. p Yes If "Yes ", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. © If "Yes ", qualifies for Yes the prescriptive path. ❑ No Is the combined weight p Yes of the PV modules and If "Yes ", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance © Yes If "Yes ", qualifies for with Section 305.4(3) of ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is one Roofing Check the type of ❑ of wood of the three types material roofing material shingle /shake checked, qualifies for Max. two layers the prescriptive path. E of composition shingle. Is the roof mounted p Yes Connections of solar assembly If "Yes ", qualifies for the solar assembly connected to roof ❑ No to the roof framing or blocking the prescriptive path. directly? • 2 1:/Building/Forms/Photo Voltaic- Checkl ist. docx ❑ Yes If "Yes ", ualifies for Is the gauge 26 or less? El No the prescriptive path. 115 lbs for 60 inch spacing or less? If "Yes ", qualifies for ❑ Yes the prescriptive path. • ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If "Yes ", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to 0 E1 0 ❑ ❑ i nc h es Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel • panels? 18 inches or less is less than 18 inches, 110011121 inches qualifies for the prescriptive path. Minimum #10 at 24 inches o /c? Size and spacing of Yes If "Yes ", qualifies for fastener? the prescriptive path. ❑ No Is the roof decking of WSP min. ' /2" thickness, © Yes decking connected to If "Yes ", qualifies for framing members Li No the prescriptive path. w /min. 8d nails @ 6"/12" o /c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the © Yes If "Yes ", qualifies for solar modules module to the roof the prescriptive path. surface. ❑ No 3 t: /Build ing /Forms /Photo Voltaic- Checkl ist.docx e. 4 Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: UniSolar Model Number: PVL -68 Listing Agency: UL 4 l: /Building/ Forms /Photovoltaic- Checklist.docx