RE: PLAN REVIEW - Restaurant FACILITY NUMBER: 34007484
Malai Thai Restaurant
Dear Ms. Ruttanapaibooncharoen:
The Washington County Depaitment of Health and Human Services Environmental Health
Program has received plans for the proposed Malai Thai restaurant to be located at 14297 SW
Pacific Hwy in Tigard, Oregon.
The plans you submitted have been approved subject to the following conditions. If any future
changes are necessary during construction, the changes must be first approved by this office.
WATER AND WASTEWATER
It is our understanding that community water and community sewer are utilized at this facility.
A grease trap or interceptor is shown on your plans. A maintenance schedule must be developed
and followed to prevent grease from being disposed of in the sanitary sewer.
Your plans show a utility mopwashing sink or curbed floor receptacle. Facilities are required to
provide either a mopwashing sink or a curbed floor receptacle for the disposal of wastewater.
Piease submit a revised plan showing either a mopwashin sink or curbed floor receptacle. No
• other fixture may be used for disposal of mopwater. If you plan to install an automatic chemical
dispensing system at your mopwashing station, please contact the local Plumbing Authority for
information on the proper backflow device needed to protect your fresh water.
Please supply a mop - hanging device so mops and similar floor cleaning equipment can be cleaned
and hung between uses.
Be advised that your hot water heater must be of sufficient capacity to meet the peak hot water
demands of your facility. If hot water availability is found to be problematic, additional hot water
generating equipment will be required. Preliminary calculations show that your facility has a peak
demand of approximately 100 GPH. To meet this demand, the recommended minimum capacity of
the water heater would be either 55,000 BTU or 12 KW.
Department of Health & Human Services - Environmental Health Program
155 N First Avenue, Suite 160, MS -5, Hillsboro, OR 97124 -3072
Phone: (503) 846 -8722 • Fax: (503) 846 -4490 • www.co.washington.or.us
Restaurant Plan Review Letter -- Washington County HHS Environmental Health Program Page 2
RESTROOMS
Your original plans show seating for 38 persons and your application shows that your plan was to
add seats. In order to add seats, you would be required to add a second restroom. Since you are not �II
willing to add an additional restroom, the maximum seats you can provide are fifteen.
One restroom is shown on the p lans. Please consult the local Building Department for information
on the ratio of toilets, urinals, and handwashing sinks required for your planned occupancy.
Restrooms must meet all the requirements as described in the Oregon Food Sanitation Rules for
design, construction, and operation. Restroom doors must self -close if they open onto a food or
dining area. There must be at least one covered waste receptacle in the women's restroom.
HANDWASHING
The plans you have submitted show one handwashing sink in the food service area. One
compartment of the three compartment sink will be required to be designated as a
handsink.
The number and placement of handwashing sinks must be adequate to serve all food service
activities including preparation, cooking, dishwashing, serving, bussing, bartending, and
restrooms. Use of handwashing sinks is restricted to handwashing only. Access to each sink
must be kept free for its intended use. Any adjacent work surfaces or clean utensils must be
protected through installation of a splash guard.
All handwashing sinks, including restroom handwashing sinks, must be equipped with dispensed
soap and towels. Common (cloth) towels cannot be used to dry hands. If disposable towels are
used, waste receptacles must be conveniently located near the handwashing facilities.
All handwashing sinks must be supplied with hot and cold water or tempered, water under
pressure. Hot water must reach at least 110 °F within a reasonable time. Metered faucets must be
adjusted to dispense for at least 15 seconds before shutoff.
Handwashing signage must be posted. Handwashing signage is available from this office upon
request.
DISHWASHING AND SANITIZING
The plans show a dishwasher. The dishwasher is assumed to be a commercial model. Home style
dishwashers do not meet code requirements. Machine or water line mounted thermometers must be
provided to indicate water temperatures of the wash and rinse cycles. These thermometers must be
accurate to +2 °F or +1°C. The dishwasher must be capable of reaching proper wash and rinse
temperatures and must waste indirectly to a floor sink. If the dishwasher sanitizes with a boosted
high temperature rinse, the final rinse temperature must reach 160 °F or higher at the dish surface. If
a chemical sanitizer is used, it must meet the requirements of 21 CFR and be dispensed in proper
concentration. An accurate test kit is required to test the sanitizer concentration of the final rinse.
You must also have a method in place to clean and sanitize fixed food contact surfaces and
equipment. If wet wiping cloths are to be used, they must be kept in a clean rinse solution with an
approved sanitizer to prevent bacterial growth.
Restaurant Plan Review Letter -- Washington County HHS Environmental Health Program Page 3
FOOD EQUIPMENT AND PLUMBING
All plumbing fixtures and installations must meet the requirements of the Oregon Uniform
Plumbing Code, including the installation of backflow devices to protect the potable water supply.
The facility must also meet any additional requirements by the City of Tigard.
Drain lines from any fixture or piece of equipment used to hold food or ice must waste indirectly to
a floor sink or floor drain. This typically includes refrigerator condensation lines, ice machines, hot
water heaters, sinks used for food preparation, soda fountains, dishwashing machines, steam tables,
dipper wells, and espresso machines.
Where an air gap is required to prevent contamination from sewage backflow, the distance between
the bottom of the drain pipe and the rim of the floor sink or floor drain must be at least one inch or
two pipe diameters,. whichever is greater. Floor drains and floor sinks must remain accessible for
cleaning and maintenance.
Your plans indicate an indirect waste connection for the dishwasher, ice maker, soda fountain, and
prepsink.
A food preparation sink is shown as one of the compartments of the three- compartment sink. Food
may not be placed into any sink that does not waste indirectly with an approved air gap as described
above. The third compartment of a three- compartment sink may be utilized for food preparation
only if it wastes indirectly. Food may not be placed into sinks of incompatible use such as
handwashing sinks, mopwashing sinks, mop basins, or utility sinks.
Wall- mounted spray guns must terminate above the rim of the sink or basin they serve. Any hose •
bib to which hoses will be attached must be equipped with an approved backflow protection device.
Chemical dispensing systems connected to water supply lines must have approved backflow
protection.
TEMPERATURE CONTROL -
Your menu indicates foods that have a cooling step. A method to rapidly cool these foods must be
provided. - Cothinercial air cooled refrigerators, ice baths,' tr cooling wands are recommended for
cooling foods. When foods are cooled in a refrigerator, they must be left uncovered until cool, and
kept well- separated to encourage air flow. Liquid foods may not be cooled at a depth of greater than
four inches and soft, thick foods may not be cooled at a depth greater than two inches in air - cooled
refrigerators. Large portions of meat should be portioned so that each portion weighs no more than
four pounds. Potentially hazardous foods must be cooled from 140 °F to 70 °F within two hours
and from 70 °F to 41 °F within an additional four hours. The total cooling time may not exceed
six hours.
Your menu indicates foods that have a reheating step. A method to rapidly reheat these foods must
be provided. Potentially hazardous food that has been cooked, cooled and reheated for hot holding
must be reheated within two hours to a temperature of at least 165 °F (74 °C) for 15 seconds.
Potentially hazardous food reheated in a microwave for hot holding must be reheated so that all
parts of the food reach a temperature of at least 165 °F (74 °C) and allowed to stand covered for two
minutes. Ready -to -eat food from a commercially processed package must be reheated to at least
140 °F (60 °C).
Restaurant Plan Review Letter -- Washington County HHS Environmental Health Program Page 4
Refrigerated ready -to -eat potentially hazardous food that is cooked in the facility and held for more
than 24 hours must be date - marked. This food must be consumed within seven days. The date of
preparation is included as the first day in the date - marking system. Food prepared onsite and then
frozen must be date - marked to indicate how long the food may be kept once the product is thawed.
This same rule applies to certain ready -to -eat potentially hazardous foods you purchase, such as deli
meats and dairy products. These foods must be date - marked once packages have been opened.
All refrigeration must be capable of holding foods at 41°F or below. Refrigerators and freezers that
do not have integral built -in thermometers must be equipped with a thermometer that is accurate to
within 2 °F. It is recommended that refrigeration temperature logs be kept.
Refrigeration units that have condensation drain lines must waste indirectly to the sewer through a
floor drain, hub drain, or other approved waste water receptacle.
FOOD STORAGE, DISPLAY, AND SERVING
If there will be self - service, please contact this office for additional information and requirements.
Self - service areas must have a smooth, nonabsorbent floor covering such as vinyl, tile, or the
equivalent extending out 30 inches on each side to which the public has access.
All food or food items in the facility which are within customer reach and are not prepackaged must
be protected from customer contamination by a sneeze shield or other approved means. Please see
the enclosed NSF pamphlet for information on sneeze shield requirements.
Lights over food storage, food preparation, utensil washing, and food display areas must be
shielded, coated, or otherwise shatter resistant.
Food may not be stored under exposed or unprotected sewer lines or water lines, except where
automatic fire protection sprinkler heads may be required by law.
All equipment and storage of food, food containers, and single service utensils must be on shelves
at least six inches above the floor except where storage is on wheeled platforms or four inch high
sealed bases. Metal pressurized containers or cased canned goods may be stored on the floor.
Storage shelves must be smooth, impervious, and easily cleanable.
GENERAL REQUIREMENTS
Your plans show designated facilities for storage of employees' personal items. The facilities
shown on the plan are approved.
All floor, wall, and ceiling surfaces must be smooth, durable, sealed, and easily cleanable.
Acoustical tiles are indicated for the food service preparation area. Washable ceiling tiles are
recommended. If ceiling tiles becomes soiled, and they cannot be cleaned, replacement will be
required. Where walls and ceilings are painted, high gloss paint is recommended. It is also highly
recommended that walls behind cooking equipment, dishwashing equipment, and the mopwashing
sink be covered with a durable, washable backsplash.
Restaurant Plan Review Letter -- Washington County HHS Environmental Health Program Page 5
If floor cleaning will take place using a wet mopping method, base coving is required on all
wall/floor junctures and no gaps shall exist larger than 1 /32nd of an inch. If water flush cleaning
methods are used, the floors must be provided with drains and be graded to drain, and the wall/floor
junctures must be coved and sealed with no gaps.
Gaps in floors, doors, walls, or ceilings around plumbing or electrical work must be filled in to
prevent rodent and insect access and entrance. Exposed utility lines and pipes cannot be installed
horizontally on the floor.
All equipment must be installed so as to be moveable or properly sealed to facilitate proper
cleaning. Floor- mounted equipment, unless readily moveable, must be sealed to the floor, installed
on a concrete or otherwise smooth base at least four inches high, or elevated on legs to provide at
least a six inch clearance between the floor and equipment.
Outside garbage storage areas or enclosures must be large enough to store the garbage and refuse
containers and must be kept clean. Garbage and refuse containers, dumpsters, and compactor
systems located outside must be stored on or above a hard, nonabsorbent surface such as cement or
asphalt that is kept clean and maintained in good repair.
This facility and its operation must meet all the Oregon Food Sanitation Rules and Statutes. Please
refer to OAR Chapter 333, Divisions 150, 157, 158, and 160 for details. A complete copy of the
rules may be obtained from www.ore•on. ov /dhs /.h/foodsafet /docs /foodsanitationrulesweb. .df.
All food service workers who handle food, drink, or utensils must have a current Food Handler
Card. For additional information call the Food Handler Information Line at (503) 846 -3460.
OBTAINING APPROVAL TO OPERATE
Your plans show seating for 15 patrons. Your restaurant license application and license fee
have been received. A pre- opening inspection must be conducted by this office prior to
license approval and operation. Please contact this office at (503) 846 -8722 at least one week
prior to operation to schedule this inspection.
Sincerely,
0
Janis McBride, Senior REHS
Environmental Health Program
Enclosure: NSF Diagram
c: Matt Poole, EHS, Environmental Health Program
Brian Blalock, City of Tigard