Loading...
Permit A. CITY OF TIGARD DEVELOPMENT SERVICES • BUILDING PERMIT PERMIT # BUP99 -0030 13125 SW Hall Blvd ., Tigard, OR97223(503)639 -4171 DATE ISSUED: 02/18/99 PARCEL: 1S135A8 -00100 SITE ADDRESS...: 10255 SW 90TH AVE SUBDIVISION TOWN OF METZGER ZONING:R -4.5 BLOCK • LOT °005 JURISDICTION:TIG REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION - CLASS OF WORK.:NEW FIRST . 2152 sf N: S: E: W: TYPE OF USE...:CMS SECOND : 0 sf PROTECT OPENINGS? TYPE OF CONST.: 5N .... 0 sf N: S: E: W: OCCUPANCY GRP.:E1 TOTAL . 2152 sf ROOF CONST: FIRE RET ?: OCCUPANCY LOAD: 82 BASEMENT.: 0 sf AREA SEP. RATED: STOR.: 1 HT: 0 ft GARAGE...: 0 sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD 0 psf LEFT: 0 ft RGHT: 0 ft FIR SPKL:N SMOK DET..:Y DWELLING UNITS: 0 FRNT: 0 ft REAR: 0 ft FIR ALRM:N HNDICP ACC:Y BEDRMS: 0 BATHS: 0 IMP SURFACE:' 0 PRO CORR:N PARKING: 0 VALUE. $ : 53750 Remarks : New modular structure at Metzger Elementary School. c Owner: -• FEES TIGARD TLN DISTRICT #23J type amount by date recpt 13137 SW PACIFIC HWY PRMT $ 44.50 DEB 02/18/99 99- 313019 TIGARD OR 97223-0000 PLCK $ 28.93 DEB 02/18/99 99- 313019 FIRE $ 17.80 DEB 02/18/99 99- 313019 . Phone #: 503 -620 -1620 PRMT $ 60.00 DEB 02/18/99 99- 313019 SPCT $ 5.23 DEB 02/18/99 99- 313019 Contractor: - PLCK $ 60.00 DEB 02/18/99 99- 313019. MODERN BUILDING SYSTEMS INC FIRE $ 60.00 DEB 02/18/99 99- 313019 PO BOX 110 9493 PORTER RD AUMSVILLE OR 97325 Phone #: 503- 749 -4949 $ 276.46 TOTAL Reg #..: 000046 -- REQUIRED ACTIONS or INSPECTIONS--- - This permit is issued subject to'the regulations contained in the Footing Insp Tigard Municipal Code, State of Ore. Specialty Codes and all other Foundation Insp applicable laws. All work will be done in accordance with MFG Structure Fo approved plans. This permit will expire if work is not started Framing 'lisp within 180 days of issuance, or if work is suspended for more Appr /Sdwlk Insp than 180 days. ATTENTION: Oregon law requires you to follow the MFG Structure Se rules adopted by the Oregon Utility Notification Center. Those Final Inspection rules are set forth in OAR 952- 001 -0010 through OAR 952- 00101987. You many obtain a copy of these rules or direct questions to OUNC by calling (503)246 -1987. • Permittee Signature: -4 Issue• By: / ` /.4 4 1 _,��_;. +++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ Call 639 - 4175 by 7:00 p.m. for an inspection needed the next business day +++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ L. CITY OF TIGARD Commercial Building Permit Application - , Recd By ' r ' 1"3125 SW HALL BLVD. New Construction and Additions Tate Recd /—P - Date to P.E. / -,2 Es- -s7- Cr-- --6-- TIGARD, OR 97223 , 1 Date to DST Pao i getkp (503) 639 -4171 Permit #eQ p -- 45 Print or Type RelatedSyVR# Incomplete or illegible applications will not be accepted Called .)(t osN ZZ°lZ- Name of Development/Project Job Metzger Modular Addition Existing Building ❑ New Building El Address Street Address Suite 10255 SW 90th Aver Building Bldg # City /State Zip Data Portland, OR 97223 Existing Use of Building or Property: Name Property Tigard- Tualatin School District School Owner Mailing Address Suite Proposed Use of Building or Property: 13137 SW Pacific Hwy, School City /State Zip Phone No. Of Stories: —Tigard, OR 97223 503 - 620 -1620 1 Occupant Name Sq. Ft. Of Project: Metzger Elementary School 2152 Name Occupancy Class(es) Contractor Modern Building Systems= El • Prior to permit- Mailing Address Suite Type(s) of Construction issuance, a copy PO Box 110 5N of all licenses • are required if City /State Zip Phone Will this project have a Fire Suppression System? expired dattabaseeT Aumsville, OR 97325 503- 749 -4949 Yes ❑ No �] Oregon Const. Cont. Board Lic.# Exp. Date Americans with Disabilities Act (ADA) Valuation X 25% = $ Participation 4637 10/2/00 Complete Accessibility Form Name Project $ 3 406 c__ Architect Selig /Lee`Rueda Valuation Mailing Address Suite ���v ■ 213 SW Ash St. 201 _ Plans Required: See Matrix for number of sets to submit City /State • " Zip - -Phone - - - on back Portland, OR 97204 503 - 224 -0173 - Engineer Name - I hereby acknowledge that I have read this application, that the information Modern Building Systems given is correct, that.LaM the owner or authorized agent of the owner, and Mailing Address Suite that plans su minted areein� c ompliance with Oregon State Laws. PO Box 110 ' - S'w'at e vuner /Agee Date J 7 City /State Zip Phone --- _..,..__� .. . 2.Z / 1 (1 �� Aumsville, OR 97325 503 - 749 -4949 Contact Person Name Phone Ron Hudson 503 - 684 -2235 Indicate type of work: New 0 Addition 0 Demolition 0 Accessory Structure 0 Foundation Only 0 Alteration 0 • Repair 0 Other 0 FOR OFFICE USE ONLY Description of work: Map(rL # tt " 4 : /� Land Use , _ ,- r Notes y} At Parks: Estimated # of Employees FTI w 44 `' , If the above figure is not supplied at the time of application, the city will i 4 -J # � " It'd ' :•� .'` :q�� '.+#'. �, '��S _,�_3d� -7 ¢:; ..'�Tr,` calculate the fee based upon the number of parking spaces. r Note: Site Work Permit Application must precede or accompany Building )-' 4 60k) I Permit Application ' V �/� L \COMNEW.DOC (DST) 5/98 --L . • • COMMERCIAL PLAN SUBMITTAL REQUIREMENT MATRIX app1iaton For an eIetrcaf submittal, the pphtatian must contain '''' ''''' . ' ' '' • ' ''''' ''' ' ' ' ' ' ' '' ' ..•„. .••••• i ff!apiR.:00:ow i lijo i iropepo.-.00!! .. 40.0 : -..#upolittolpt:J307.rtiv.itottiiiAmai:a: COM .... ........... „. ......................... . .. signature of the supervisnig electrician beftre plan review will be cducted After plan review approval, PIaris Examnier w11 contact the appitcant t request additional plan sets for dsthbution purposes (Copy for Contractor City, Washinton County, Tualatin ............ Valley ..... Fire & .... TYPE OF SUBMITTAL Plans ... .. KEY: Submitted S (Private) 1 S = Site Work B (New or Add) 1 B = Building F (New or Add or Alt) 3 F = Fire Protection System M (New or Add or Alt) 1 M = Mechanical B & M (New or Add) 1 P = Plumbing P (New, Add, or Alt) 2 E = Electrical B & M & P (New or Add) 2 New = New Building • E (New, Add, or Alt) - 2 - Add = Addition B & F & M & P & E 3 Alt = Alternation to Existing (New , Add) Building • • NOTES: 1:\dsts\forms\matrxcorn.doc 10/29/98 CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 _� BUP Date Requested 3-;.4-1-619 AM PM BUp `lc - Oa& I Location ier IO2SS gaf Suite MEC Contact Person . Ph Sg ?S JY PLM or Contractor Ph 6%4 - 23S 3 SWR BUILDIN Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: /�,��r� Slab SIT 'WV a Post & Beam Ext Sheath /Shear „4 Int Sheath /Shear Framing Insulation r ' Drywall Nailing • / a . /A`' Firewall 'i%Q Fire Sprinkler /54 P - 5 Fire Alarm Sus 'd Ceiling G_ (� } 5 Roof Misc: PART FAIL Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final �o PASS PART FAIL C1 (p\ MECHANICAL . � ck/ �� Post & Beam Rough In Gas Line 4R Smoke Dampers Final PASS PART FAIL ELECTRICAL Service PC(j) Rough InUG /Slab Low Voltage Fire Alarm Final PART FAIL Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk .3 ^r�1 ' Vt, p O Ext Date - V Ins ector ; P.AS' PART FAIL DO NOT REMOVE this ins ection record from the job site. 01" P J Page No. 1 CASE HISTORY FOR CASE NO.: BUP99 -0030 TIGARD TLN DISTRICT #23J 10255 SW 90TH AVE 03/26/99 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By BUPC950 (F) Issue Cert. of Occupancy / / / / 03/24/99 03/26/99'JT BUPF005 Application received / / / / 01/22/99 RECD DRA 01/27/99 GEO BUPF008 Permit Created / / / / 01/27/99 DONE GEO 01/27/99 GEO BUPFO10 Check for prcl. restrict. / / / / 01/28/99 TIF fee letter sent on 1/18/99. Geo DONE 01/28/99 GEO BUPFO12 Plans routed to Plans Examiner / / / / 01/28/99 SENT GEO 01/28/99 GEO BUPF026 Plans approved by PE / / / / 01/30/99 APPR RDP 01/29/99 RDP IR BUPF030 Reviewed plans routed to DSTS / / / / 01/30/99 APPR RDP 01/29/99 RDP BUPF032 DST Post- Review Completed / / / / 01/29/99 Hold until site permit issued. This DONE DEB 01/29/99 DRA permit is in the HOLD area. BUPF032 DST Post- Review Completed / / / / 02/17/99 Site permit is ready to be issued. 'Hold MEMO B 02/17/99 BON status released. BUPF052 Hold Release to Pending Status / / / / 02/16/99 ok to issue - hold is for the issuance RDP 02/16/99 RDP of site permit. BUPF080 (F) Ready to issue / / / / 02/17/99 Applicant must be issued site permit MEMO B 02/17/99 BON before issuing this building permit. BUPF092 (F) Issue building permit / / / / 02/18/99 DONE DEB 02/18/99 DRA BUPF705 Footing Insp / / / / / / _ 01/27/99 GEO BUPF706 Foundation Insp / / / / 03/05/99 PIERS APP. PASS RC 03/05/99 ROC BUPF708 MFG Structure Footing Set -Up / / / / / / 01/27/99 GEO BUPF725 Framing Insp / / / / / / 01/27/99 GEO BUPF750 Appr /Sdwlk Insp / / / / / / 01/27/99 GEO BUPF775 MFG Structure Set -Up Final / / / / / / 01/27/99 GEO BUPF780 Case Finaled / / / / 03/24/99 PASS AKJ 03/24/99 AKJ BUPF799 Final Inspection / / / / 03/09/99 NEED LIT EXIT SIGNS FAIL RC 03/10/99 ROC NE3ED TO PERFORM PULL TEST ON ALARM NEED 11 SQ FT OF VENT UNDERFLOOR ACCESS TO UNDER FLOOR MUST BE READILY ACCESSIBLE OCC WITH OUT APPROVAL PRINCIPAL OF SCHOOLNOTIFIED BUPF799 Final Inspection / / / / 03/24/99 PASS RC 03/24/99 AKJ