Correspondence July 20, 2005 �_' FA
CITY OF TIGARD
Carleton Hart Architecture OREGON
Brad Simmons
322 NW 8 Ave
Portland, OR 97209
RE: GREENBURG OAKS — STORAGE ROOM ADDITION
Project Information
Site Permit: BUP2005 -00311 Construction Type: V - B
Tenant Name: Greenburg Oaks Occupancy Type: S -2
r Address: 1 SW 91 Ave Occupant Load: (1)
Area: Add: 182 sq. ft. Stories: 1
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004
edition; and 2003 International Fire Code as amended by TVF &R. The submitted plans are
approved subject to the following conditions.
1. All exit doors shall be openable from the inside without the use of a key or any special
knowledge or effort. 1008.1.8 OSSC
2. Special Inspection: Special inspection is required for Epoxy Bolts. The special inspection
agency shall furnish inspection reports to the Engineer /Architect of Record, the General
Contractor, LMC Inc. and the City of Tigard, Building Division, attention Hap Watkins.
All discrepancies shall be brought to the immediate attention of the general contractor for
correction. The special inspector shall submit a final signed report stating whether the
work requiring special inspection was, to the best of the inspector's knowledge, in
conformance with the approved plans and specifications and the applicable workmanship
provisions of the code. 1704 OSSC
3. American with Disabilities Act (ADA): It shall be the responsibility of the Architect,
Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the
ADA requirements for the structure. The City of Tigard reviews the plans and inspects the
structure only for compliance with Chapter 11 of the OSSC, which may not include all of
the requirements of the ADA.
4. Live Loads Posted: The live loads for which each floor has been designed to exceed 50
psf shall be conspicuously posted by the owner in that part of each story in which they
apply, using durable metal signs, and it shall be unlawful to remove or deface such notices.
The occupant of the building shall be responsible for keeping the actual load below the
allowable limits. 1603.3 OSSC
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
•
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be
maintained on the jobsite. The plans shall be available to the Building Division inspectors
throughout all phases of construction. 106.3.1 OSSC
Certificate of Occupancy: No building or structure shall be used or occupied until the Building
Official has issued a certificate of occupancy 110.1 OSSC
Premises Identification: Approved numbers or addresses shall be provided for all new buildings
in such a position as to be plainly visible and legible from the street or road fronting the property.
When submitting revised drawings or additional information, please attach a copy of the enclosed
City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in
tracking and processing the documents.
Resp r
Val Henzel,
Senior Plans Examiner
•