Specifications LEIGH'J pooF IEVICE, IAC
February 12, 1997 •
Specifications for Metzger Elementary - Area "4"
1.) Tear off existing roof membrane and roof down to sheathing.
2.) Apply one (1) layer of 2.5 Polyiso roofing insulation, apply one (1) layer of
1/2" fiberboard, both layers secured with mechanical fasteners.
3.) Apply three (3) plies of Tremco composites ply set in Burmastic adhesive at
the total rate of nine (9) Gals. Per 100 Sq. Ft.
4.) Apply flood coat of Tremco's Ecolastic at the rate of five (5) gals. Per 100 Sq.
Ft, embed 1/4" / 10 crushed gravel at the rate of 300 Lbs. Per 100 Sq. Ft.
5.) Flash curbs and HVAC units with Tremco HP4510 Hypolon sheet set in
adhesive.
6.) All sheet metal items to be 26 Ga. Prepainted metal.
CITY OF TBGARD : ..._
Approved
Con. +tt;onalfy Approved [
For only the work as described in:
FED NO /31 S9 ___
s ._ _ i[::i' to: F-01lOW
Attach L T; _
755 Alpine Avenue • P.O. SOH 14 • McMinnville. OP 97128
C503) 472 -0031 • C503) 364 -1938 • Foci (503) 434 -5491