Loading...
ROW2011-00001 APPLICATION FOR WORK IN RIGHT -OF -WAY (ROW) PERMIT • • = Development Engineering TIGARD • . 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 FAX: (503) 624 -0752 FOR STAFF USE ONLY General Information: WR 607180 Right-of-Way Property Address/Location(s): Abt 12500 SW Karen St. Case No.: , � )/J �D/ 1 ) )0 1 Tigard � Receipt No.: Date: I ) )1/ *Applicant's Name: Portland General Electric Application Accepted By: ,S -r(2047 Rrviced 1/4/09 lFy I • 2 7 / —' g Address: 9480 SW Boeckman Rd REQUIRED SUBMITTAL INFORMATION City /State: Wilsonville OR Zip: 97070 Primary Contact: Lorraine Katz Phone: (503) 570 -4407 Fax: (503) 570 -4420 Submit a scaled sketch of the proposed work to be done Contractor's Name: N/A CCB# Expiration: Professional Engineered Plans are Address: required for: City /State: Zip: • Street Widening Phone: Fax: • Subdivision Infrastructure • Main utility line extension: Plans By: Address: City /State: Zip: Phone: Fax: Description of work: PGE to replace bad order primary & install vault. PGE will be doing the bore & will use a PGE approved contractor. Estimated value of work (within the public right -of -way): $ Is work related to a LAND -USE DECISION? YES NO If so, please specify (MLP, SDR, SUB, etc.) case #: Is the work related to a BUILDING PERMIT? YES NO ■ If so, please specify (BUILDING PERMIT) case #: *NOTE: Person specified as "Applicant" shall be designated "Permitee" and shall provide financial assurance for the work. c:\users lshirteytapptlata\ local\microsoft \w ndows \temporary internet files \content. outlook \gkOsyiwb \city of tigard permit wr 607180.docx N l , t CITY OF TIGARD RIGHT OF WAY PERMIT i COMMUNITY DEVELOPMENT Permit #: ROW2011 -00001 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2421 Date Issued: 01/28/2011 i Parcel: SEG905 Jurisdiction: TIGARD Site address: Subdivision: Lot: Project: Portland General Electric Project Description: About in front of 12500 SW Karen St., PGE to replace bad order primary and install vault. PGE will be doing the bore and will use a PGE approved contractor Owner: FEES PGE Description Date Amount TIGARD, OR 7) L! ; �J� PHONE: 503 - 570 -4407 � , - (JG/ l✓'�' Contractor: PHONE: FAX: Applicant: LORRAINE KATZ 9480 SW BOECKMAN RD WILSONVILLE, OR 97070 PHONE: 503 - 570 -4407 1) Total Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee /Applicant Signature: lbritit Issued By: /` Special Conditions (See Attached) Note: THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for ROW2011 -00001 Type: Condition Name: Status: Severity: ROW 01- CUSTOM CONDITION Applied Notice <Custom Condition goes here> ROW 02- PERMIT & PLAN REQ ON SITE Applied Notice A copy of the permit and all attachments, and a copy of the approved construction plan and all amendments shall be available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's Standards and Specifications and to these General Conditions. Changes to any of the aforesaid must be approved by the City, in advance of work performance. ROW 03 -TRAF CTRL - SPECIF (CITY) Applied Notice The City's standard specification for traffic control is "Manual on Uniform Traffic Control Devices for Streets and Highways ", U.S. Dept. of Transportation, F.H.A., 1988 Ed. ROW 04 -TRAF CTRL -CONTR RESPON FOR Applied Notice Traffic control shall be provided for by the contractor in accordance with the City's standard specification and, also, in accordance with a City (job specific) approved traffic control plan. A copy of the approved traffic control plan shall be available at the work area. ROW 05 -TRAF CTRL -ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time, without having first obtained written approval from the City Engineer. The permit holder is responsible for provision of timely notification of traffic flow disruptions to area wide Emergency Services (Tigard Police Dept., Tualatin Fire & Rescue) and to Tri -Met and Tigard School District. ROW 06 -TRAF CTRL - ADVANCE WARNING Applied Notice Advance warning of imminent traffic disruption shall be provided to the general motoring public by placement of an advance notification sign at each end of the construction area 72 hours (min.) before initiation of construction work. ROW 07 -TRAF CTRL -PRIV PROP ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service and if not, shall be cause for work stoppage until effective access is established. ROW 08 -TRAF CTRL - DEVICES IN PLACE Applied Notice Traffic control devices, flagpersons, etc., shall be in place prior to initiation of construction work and shall be effectively maintained. ROW 09 -TRAF /NOISE CTRL -WORK HRS Applied Notice No work will be permitted during the hours of darkness, nor between 9:00 p.m. to 7:00 a.m. Monday through Friday, nor between 9:00 p.m. to 8:00 a.m. Saturday, nor between 9:00 p.m. to 9:00 a.m. Sunday. ROW 10 -TRAF CTRL -MIN LANE WIDTH Applied Notice Minimum travel lane width shall be eleven (11) feet; pedestrian travel shall also be provided for. ROW 11 -TRAF CTRL -CITY CAN MODIFY Applied Notice • The City reserves the right to add to or modify traffic control requirements as may be necessary to effectively control traffic and to assure public safety. ROW 12 -INSP 24 HR NOTICE REQUIRED Applied Notice The permit holder or his contractor shall notify the City's inspector Zen Dutson, at 503 - 718 -2472 or email at zen @tigard- or.gov, twenty -four (24) hours prior to commencing work, twenty -four (24) hours prior to any staged inspection, and after completing work covered by the permit. ROW 13- HAZARDS -CERT OF INS Applied Notice Maintenance of the work area and approach roads is the responsibility of the permit holder. The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. A copy of the permit holders Certificate of Insurance shall be available at the work area. ROW 14- DEBRIS - MATERIALS Applied Notice The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate cleanup and stoppage of work to accomplish cleanup. ROW 15- EROSION CTRL REQ Applied Notice Effective erosion control is required. Erosion control devices must be installed and maintained meeting D.E.Q. requirements. The City may at any time order corrective action and stoppage of work to accomplish effective erosion control. ROW 16- REPAIRS -LIKE MATERIALS REQ Applied Notice Property disturbed by construction activity shall be seeded with a standard grass mix; shrubs, flowers, barkdust, existing signs, pavement markings, mailboxes, etc., shall be reestablished, reinstalled or replaced, with like kind and material. ROW 17- DRAINAGE CONTROL REQ Applied Notice Effective drainage control is required. Drainage shall be controlled within the work site and shall be so routed that adjacent private property, public property and the receiving system is not adversely impacted. The City may, at any time, order corrective action and stoppage of work to accomplish effective drainage control. ROW 18- UTILITIES PRELOCATION REQ Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0080. Copies of the rules may be obtained from the Center by calling (503) 232 -1987. If you have questions about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holders expense. ROW 19- UTILITY LOCATIONAL CONFLICT Applied Notice Contractor must verify all existing utilities for both vertical elevation and horizontal location prior to start of work (pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the permit holders expense. Changes must be approved by the City in advance of work performance. Contractor shall coordinate the work with affected utility agencies. ROW 20- TRENCH - PATCH /SAFETY /LBILITY Applied Notice A temporary hard - surface patch (Cold mix A.C. or Hot mix A.C. base paving) shall be placed on trenches within roadways at the end of each day's work. No trench, on site or off site, shall be left at any time in an unsafe condition. The permit holder is responsible for and is liable for hazards or damage resulting from the work. ROW 21- REPAIRS REQ - INSPTR OPINION Applied Notice Work provided for under the permit shall include repair of existing facilities (roads, ditches, etc.) as may be necessary, in the City Inspectors opinion, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the permit holders expense. ROW 22 -AS- BUILT /ENGR CERTIF REQ Applied Notice At the end of each year, or an a mutually agreeable yearly date, any entity making changes to its facilities in the public right -of -way shall submit complete "as- built" drawings showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineers certification of installation compliance (form attached). ROW 23 -DAILY INSP REPORTS REQ Applied Notice The permit holders Engineer /Inspector shall submit daily inspection reports, on a weekly basis, to the City's Inspector. (see Developer- Engineer Agreement note #5). ROW 24- TESTS /REPTS TO VALIDT CLMS Applied Notice The City's Inspector may, at their discretion, require provision of tests and or reports from the permit holder, permit holder's engineer or contractor to validate claims of material or construction adequacy /compliance. Such tests /reports shall be provided at the permit holder's expense. ROW 25- RELEASE - WAIVER REQ Applied Notice The permit holder shall provide a copy of a properly executed Release & Waiver document to the City for each ownership disturbed by construction activity, as evidence of disturbance resolution and owner satisfaction. ROW 26- MONUMENT PROTECTION REQ Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holders expense. ROW 27 -PROB SOLVING - RESPON PARTY Applied Notice The permit holder shall provide to the City Inspector, in writing, the names and 24 -hour emergency telephone number of two (2) persons who have authority to resolve problems, take corrective action and, in general, will be responsible in case of an emergency. The permit holder shall notify the City Inspector, in writing, of any /all assignment changes. ROW 28- CONSTR SAFETY - RESPON PARTY Applied Notice The permit holder shall cause his contractor to provide to the City Inspector, in writing, the name and 24 hr emergency telephone number of a designated "Competent Person" responsible for construction safety as per OR -OSHA, Chap. 437, Div. 3 Construction, Subdivision P - Excavations. The contractor shall notify the City Inspector of any /all assignment changes. ROW 29- ESMT /RT OF ENTRY - RESPON Applied Notice It is the sole responsibility of the permit holder to provide for proper right -of -entry and /or easements prior to starting work. Proof of right -of -entry, or properly executed easements, shall be provided to the City. The City shall in no way be construed to be liable for the permit holder's failure to obtain or provide for proof of right -of -entry or easements. I r 01823- 00535/ \ V ` ' 7 I PL 06 y\ 06848 ' lZ I C AA - - __ _ _ _ _ - - I1 1973 -20 . I I' g : 0 • • 01826- 1 00580/ F I' Y 01 026- PL 06006 06006 .-, .00 1982 -20 I - to CU - 'PL - 80592 PGE CONTRACTOR TO EXTEND 8. REROUTE ,>. a B 100 2967 EXTG 4' PVC FROM I SPLICE POINT TO VT 110 -I - _ -- -- p ., 80592 0 I - - - — BY CONTRACTOR, EXTEND INEW 4' PVC i x I Q 1 975 -2 FROM INEW) VT 110 TO VT 6343. H- a Q r - OPEN I I Q REMOVE EXTG 3 - •2 1L JKT"IN - EVTG '- FU I VT 063 N 0 r--.. 0 ° "C ='� - 4' PVC TO- SPLICE _POINT. - LJ N \ 1- GO I 1 3 a ' 01826- OPEN I `O ° I I C-2 AL XLP JKT -DI L . • FLD6X03 I ..I ¢ � ' % B-2 AL XLP JETT -D -- - Fn • 06003 OPEN \ '\ \ S ' / A - 2 AL XLP JKTI-D • CONTRACTOR TO 2003 -20 V \ ;n a x I/ � g REPAIR SIDEWALK 0 _ \\ '\\ i __. — __ - ' i 01823- - p- C - 2 q REMOVE i �l S KAREN ST ' PL 0 0'6847 6:826- O / 00350/ :! XL ! : sTD6 VTIOSO6 CHECKLIST - ' 27 C 25 '582 AL -TD 2I I • xa �� � ❑ 826 \ BC -2 AL - Tx - D BOOM PO 00059 OI 826- 00560/ O7 E261 VT 00: i 0 OACKHOE 00340/ f� V P zoo -;0 / OPEN` r Pct TRENCH x Ea+iRAaoa oLC60' OPEN' PL 06001 \ P1991,20 96005 l /.l 1 -to cu -ix A 25 60859 I 01826- 01826- �99 PO 00058 i 1 Q LOCALES X CONTRACTOR 002900 Al - 0 a 0 1 12580 , 12520 1 i 2500 P FLA STAKNG PL 05999 S PL 0 0060 l SW KAR EN _ ' SW KAREN SW KAREN SW KAR ;L _ .. � �n �, 06001 __ J GGING A 2 AL ,.% - - K i r . 1988 -20 J69393 - 72 .� TREETRIM • ( LANDSCAPE X SDEWALK APR VT 05905 v # ASEMENT X Lo LO PERMITS K TOAD ROW N I CUTSHEET N J68766 -72 A 50 12454 uc CR.VER, nunis 455XW 1 12504 rj SIUTDOWN 01826 SW KAREN CDSLOLER 003'.0/ ,2 0 / $Ip11DOWN PL 06000 I I V VT 06678 DOOR RANGER CONTACT COMPANT GREW IC REPLACE miSSING TAG 0 01 05906 PH. C. DATE TILE LEGEND CONSTRUCTION NOTES SFEXT -N NEW PGE FACILITIES TO BE INSTALLED • U , I. CUSTOMER TO PROVIDE ALL TRENCHING AND BACEFILLINL. TRENCH i0 BE 660 -PGE SWITCH VAULT. 4= j 1 �`y� ¢ 36 INCHES DEEP AND 24 RICHES WIDE, MEASURED FROM FATAL GRATE. PROVIDED & INSTALLED OR CUSTOMER lull F 2. CONDUIT or NECESSARYI WILL BE GRAY. SCHEDULE 40. ELECTRICAL GRADE. Q FAULT INDICATOR 4F p PVC CONDCONCH, Ran NYLON PuIL STRINGS IMIN.500 LBS. TESTI. Safe, F PGE 10 DETERMINE THE AND R OF CONDUITS NSiALL CUTOUT WOTIC Cv,. t MAINTAIN 12 VERTICAL T 1 24 HO ANO 21 nOR120Nte RI CLEARA CHES CLEARANCE BETWEEN ' SIZE F AS NOTED tl Safe GAS ANO OTHER UBR.IFIES. 4 ES. ALL ELBOWS TO BE 0 36 INCH HAM) RADIUS. COMMON SENSE BENDS MUST BE FACTORY LADE. RIGID STEEL OR POE APPROVED FIBERGLASS BENDS ARE REQUIRED FOR RUNS OF ISI FEET OR LONGER.OR FOR ANY LENGTH INSTALL 3 - •2 AL JET PRIMARY IN N T PVC CONDUIT RUN WITH MORE THAN LBO DECREES IN BENDS. PVC SCHEDULE 40 BENDS ARE ACCEPTABLE PROVIDED & INSTALLED BY PEE CONTRACTOR FOR RUNS OF 150 FEET OR LESS. THE MAXIMUM TOTAL BENDS RI ANY CONDUIT T Roll RUN IS (UNLESS OTHERWISE SPECIFIED) ZTO DEGREES INSTALL 3 - •2 AL JET PRIMARY IN EXTG 4" PVC CONDUIT 3. CUSTOMER RESPONSIBLE FOR ROAD CROSSINGS. USE ONLY CRAY, SCHEDULE 40. PROVIDED & INSTALLED BY PGE ELECTRICAL GRADE, PVC CONDUIT WITH NYLON PILL STRINGS 0..500 LBS. IESTI. 1 4. SINGLE PRIMARY INSTALLATIONS - CONDUIT 10 EXTEND A MINIMUM OF 10' FROM {� / / //I CUSTOMER SEMENT TO PROVIDE SIDE W X K 5 ' vzccn EA BEHIND TRANSFORMER PLO. 5. ALL PGE TRANSFORIAERS 70 BE INSTALLED VICINITY MAP BUILDING. RALLOROVERHANGAND 4 FEET B N O N COMBUSTIBLE MWO FROMANYFIRE HYDRANT. PGE TRANSFORMERS MUST BE WITHIN 15 FEET OF A DRIVEABLE AREA. ALWAYS MAWTAW IO FEET CLEARANCE w FRONT OF ALL TRANSFORMERS. AS -BUILT VERIFICATION This document occurately F'I aQ ' VT -00110 ^,: : 6. CuSTOMER TRENCH AND FLOOD CONFIGURATIONS MUST BE INSPECTED BY PGE PRIOR & NESC VIOLATIONS CORRECTED represents FIELD construction. F GF 0 . ' -- � 1 1__ W C,':'3.,%5 NE I S DC4i10vS TO BACKFLLING. PLEASE CALL 503 •136 -5850 TWO DAYS PRIOR TO INSPECTION. Foreman: Date: SW II I I _ S .. _ _ - _ _ ___ _ f \ f1, PROVED 6v PGE. 7. DESIGN 1S BASED ON STANDARD UNDERGROUND EQUIPMENT. NON.STANOARD UNOGERGROUNO EOURUENi MAY BE AN OPTION Al AN ADDITIONAL [051 i0 THE CUSTOMER. SIX/Engineer: Data - ¢ _ / e i0OVET 4R4GP Oef Y PGD TO sEt L1 FINeL Designer: Date: m _ ' - ' _ = E, BE. sew Per ganOGenerol corn www Por tlondGener of biz www Eor lhAdvdntoge,com PPN _ / ° Qc NOT CR055 TITLE JOB N0. a � . > r - qC> �O, ! 6 V - - ' 9 ° 5 LAW BEFORE YOU DIG: OREGON w REQUIRE$ YOU TO REOU UTILITY LOCATION PGE - REPLACE B/0 CABLE 607180 9 l 1 - - " - P _U _ - _ , Si ALI SOU )- lB 2 BUSINESS DAYS CWCUIT SIZE 4.1N I F ' � - SW KTNEFINE V S i91NG IN PI IN IEEE PvC. NOTIFICATICATION CENTER ERIOR TO EXCAVATION. FOR LOCATES CALL THE OREGON UTILI TER AT BIT ` TIGA - 13362 17X22 1 - - 1 I /GE DESCRIPTION SCALE a A G, _ .,a- Joe STC �' A • l,\ 660-PCE CONTACT "EN FOREMAN ano /oF CDNOUT wSPECTOR 7 To Io ` / REPLACE B/0 PRIMARY. INSTALL VAULT I' =60' P - '� \ SWITCH VAULT WORKING INSPECTION OUIRED PRI PRIOR D EXCAVATION. 0 ti ■ N SW W _ <AREN S % CONDUIT INSPECTION RE R TO BACKFI OCATION vt e 9 $ PGE w1LL NOT INSTALL WIRE UNTIL TRENCH IS 100'/. BACKFILLED. ABT 12500 SW KAREN S7, TIGARD: WA CO .5 - - �\ � DATE SECT10N151 wORR WITH SHEET J - - N A Qj / JIM K ' : "' � AC EK ' WIL SONVILLE 10/6/2010 021 -030 • ' GENERA FORE � I OF 1 _ '�P LAT CREW CENTER 6' PHONE: (5031612 -5502 CELL: 969 - 6103 DESIGN BY PHONE 14031 655 B4 - sw waLr+uT sl _ I_ � 3•. r F eJ „ Know what's below. SW LE O 97 RM RD LORRAINE KATZ 570-4407 BRIG 0 -4407 BRIGAN TE WOE SONE S0- 4IALIST : JEFF BDER C before ou wls Wasarvv0.LE. OR BTO7D 655 -84 I � PHHONE: :15031 (5031570 -4404 CELL: 849 -654BN- 6SR8 Y 41 9• OPOPTL4ND GENERAL ELECTRIC C0.- ALl RIGHTS RESERVED