Correspondence September 14, 2010 016 '4
\� r
p � 14 _ 6
CO
ry G s p l \S \ � James G. Pierson, Inc.
.. \\. Since ,945 .
City Hall - Building Department V 5
Attention: Special Inspection Section
A NC ' " eE�`
13125 SW Hall Blvd
Tigard, Oregon 97223 -8199
FINAL SUMMARY SPECIAL INSPECTION REPORT
- 7 69 '5 SW Gonzaga Street Tigard, Oregon
For: National Safety Co. - New Office Building
Permit BUP2009 -00077
This memorandum will confirm that structural construction is complete on the above project and
to the best of our knowledge as Structural Engineer of Record, has been accomplished in accordance
with our design intent and in compliance with the contract documents of the above permit.
Special Inspection was provided by Carlson Testing Inc. in accord with the permit
requirements of the project. We are in receipt of the Final Summary Letter by Carlson Testing Inc.
dated September 13 2010 which indicates that the required inspections and tests were performed
and the work found in compliance with approved plans and modifications thereof. There are no
outstanding issues in regard to tests or inspections reported therein or know by us to exist.
Based upon this information and upon our knowledge of the canopy work completed, we
believe that the construction delineated by the above noted permit is satisfactorily completed, and we
recommend that the permit be closed out in accord with the City of Tigard procedures.
Sincerel yours
4 _00 PROFF
O
. ®
R. GD_
EXPIRES: JUNE. 30,
Peder R. Golberg, PE /SE
Consulting Structural Engineers
320 S.W. Stark, Suite 535 Portland, Oregon 97204 Tel: (503) 226 -1286 Fax: (503) 226 -3130
Rick Bolen
From: Walter Barnett
Sent: Thursday, January
•
07, 2010 7:08 AM
To: Rick Bolen
Subject: FW: National Safety
• Office Building
•
From: Cheryl Caines
Sent: Wednesday, January 06, 2010 11:41 AM
To: Albert Shields; Walter Barnett; Dick
Bewersdorff
Subject: FW: National Safety Office Building
•
FYI
From: Cheryl Caines
Sent: Wednesday, January 06, 2010 11:40 AM
To: 'skourtes @aol.com'
Subject: National Safety Office Building
Mr. Skourtes,
•
It has come to my attention that the street side
windows have been modified on your building
at 7095 SW Gonzaga. A site visit revealed that
one of the windows has been removed and
another was relocated near the east end of the
building.
Based on the plans provided, 270 square feet is
required to meet the 50% window coverage.
The approved plans show 285 sq ft. One
window at 30 sq ft was removed — reducing the
coverage to 255 sq ft. Please ask your architect
to provide calculations to show how the 270 sq
ft minimum will be met.
Thank you.
Cheryl Caines
•
Associate Planner ••
City of Tigard - f ail
(503) 718 -2437 � , / 'j'
1
{
DISCLAIMER: E- rnails sent or received by City
of Tigard employees are subject to public record
laws. if requested, e -mail may be disclosed to
another party unless exempt from disclosure
under Oregon Public Records Law, E -mails are
•
retained by the City of Tigard in compliance with
the Oregon Administrative Rules "City General
•
Records Retention Schedule.'
•
•
2
4e1/11 18 :05 503- 224 -5536 DTL r�RCHITECTP;
... r- PAGE E12
.
DiBeTnedetto January 11, 2010
Thams01
�,iciin st,on�:; Building Department
1L�retnitc�otH City of Tigard
aiz
Portinnd, OR 97239 Re: Proposed Office Building at 7105 SW Gonzaga St., Tigard, Oregon
(303) 2 Permit No. BUP2009 -00077
k ax(SCC4) 214593
esseeetleeeenees Response to Inspector
This permit is currently under construction and the following remarks are in
response to issues recently raised by the building inspector at the site.
1. The Oregon Faon- Residential Energy Code requires R -13 insulation for
exterior framed walls. The exterior walls were frame with 2xe studs for
structural reasons, and the drawings indicate R -19 bait insulation
between the studs, per the Code footnote for framed walls that ems
Insulation should be to the fu11 depth of the cavity. The building owner
. informs us that he used an R -13 batt that has expanded to the full cavity
2. The drawings indicate to brace and support the suspended ceiling system
per requirements of a City of Portiand Code Guide. The requirements
should have been per the 401 - Oregon document issued by the Oregon
State Building Codes Division. Document 401 - Oregon supersedes the
details shown on the drawings.
3. The emergency -only exit door at the south elevation is shown to be
recessed from the face of the building. Tigard Planning Department has
concluded that this door need not be recessed, and the owner will install
the door flush with the building face.
4. A window on the first floor of the south elevation has been moved near
the east end of the building, per the attached drawing..
Sincerely .
Michael Medias, CSI, CCS
DiBenedetto /Thornson/Livingstone Architects, P.C. .
Cc: John Skourtes
e
A. T 75ittronknra. TATA
Sa+m G. Tt,Q,xwa. MA '•
Don i+r nrwes..W
Micron. Melba. G5