Loading...
Plans r ,. . ., •, ' ROCKY MTN. HARDWARE TENANT IMPROVEMENTS rr PROJECT DATA PROJECT TEAM Y II OWNER: TOM CLARKE (h `" C C C C C C C C C C C C BUILDING LOCATION: 7357 SW BEVELAND STREET. I � 12439 SW 22ND AVE. TIGARD, OR 97223 I LAKE OSWEGO 97035 �i ZONING ORDINANCE: CITY OF TIGARD ` 4, _ P GENERAL CONTRACTOR: SEQUOIA WOODS DEVELOPMENT CO. LAND USE ZONE: MUE 12439 SW 22ND AVE. LAKE OSWEGO, OR 97035 ." BUILDING CODE(S): 2003 IBC TYPE OF FACILITY: RETAIL STORE SHEET INDEX _ CONSTRUCTION TYPE: V -B A0.1 TITLE SHEET & PROJECT DATA L.. OCCUPANCY GROUP: M A1.0 LOWER LEVEL TENANT IMPROVEMENT PLAN I1l A1.1 LOWER LEVEL REFLECTED CEILING PLAN I • • e• LOWER LEVEL TENANT IMPROVEMENT SPACE: 895 S.F. •°- 01I OCCUPANT LOAD RETAIL: fl95 S.F / 30 S.F. PER OCC. = 30 OCCUPANTS • • • • . : \,\ TOTAL OCCUPANT LOAD = 30 OCCUPANTS tl eGe I — `�' l‘q / k � 118 S0. FT. EXITS REQUIRED: < 50 OCCUPANTS = 1 REQUIRED EXIT vaN `) �10 i STORAGE 153 SO. FT 1 ) STORAGE _I • � EXITS PROVIDED: 2 J '`` G \AY O F �D v \ o N EXIST MECH. RM 2 E . M I + 1 80 \1 v - .1p ` EXIST. ELE . MECHANICAL, PLUMBING AND FIRE SPRINKLER DESIGN BUILD NOTES II IEaxP. .m. � - SHOWROOM I SCOPE OF WORK TENANT 1 I 627 SP: FT. 1. ALL MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SPRINKLER WORK SHALL BE PROVIDED UNDER A SEPARATE EXIST. EXIST.M N EXIST. IMPROVEMENT SPACE CONTRACT AND PERMIT. SUBMITTALS SHALL BE DEFERRED. ; • O WOMEN ELV. I v I I — , iii 2. IT IS THE DESIGN/ BUILD CONTRACTOR'S RESPONSIBILITY TO CONFORM TO ALL APPLICABLE BUILDING CODES AND TO 1 � �' . PROVIDE ALL DOCUMENTATION REQUIRED TO OBTAIN PERMITS FOR WORK UNDER THEIR CONTRACT. ... .cORRIO�_ • ��. ®y CITY F TI V ' 9 3. THE OWNER AND DESIGNER ARE NOT RESPONSIBLE FOR ADDITIONAL COSTS INCURRED DUE TO DESIGN /BUILD , ® : ¢`. — CONTRACTOR'S ERROR AND OMISSIONS. V _ _ APPrO •• . f f .. I V • Conditionally approved [ l W / / Letter to: Follow [ l V BIDDER DESIGNED ELECTRICAL CRITERIA [ EXISTING TENANT IMPROVEMENT SPACE 1. ELECTRICAL DESIGN CONTRACTOR WILL COORDINATE POWER, SIGNAL AND LIGHTING DESIGN AND PROVIDE ' I ® y Perntitt �'a . = ! r • CALCULATIONS IN CONFORMANCE WITH STATE ELECTRICAL CODE, ENERGY CODE AND BUILDING CODE. 1 4. �AS 3,3. �.. �: 2. ELECTRICAL DESIGN CONTRACTOR WILL REVIEW THE PROGRAM DRAWING AND WILL MEET WITH THE TENANT TO FINALIZE • ir "7• \ '•� �� : -• � "r ' • "'� �! THE EXACT POWER LOCATIONS AND REQUIREMENTS FOR EQUIPMENT. DESIGN WILL PROVIDE FOR CODE REQUIRED AND MAINTENANCE RECEPTACLES. DESIGN WILL INCLUDE FIRE ALARM SYSTEM IF REQUIRED, COORDINATED AND EXTENDED a FROM BUILDING FIRE ALARM SYSTEM. OUTLETS, PHONE AND DATA JACKS SHOWN ON ARCHITECTURAL PLANS (IF ANY) YS` • ARE MINIMUM REQUIRED AND MAY NOT INCLUDE ADDITIONAL OUTLETS REQUIRED BY CODE OR FOR MANTENANCE. le 3. ELECTRICAL DESIGN CONTRACTOR WILL COORDINATE HIS WORK WITH THE DESIGNER AND WITH THE HVAC AND FIRE �\ 04 SPRINKLER DESIGN /BUILD CONTRACTORS. /� Occupan» Type 4. ELECTRICAL DESIGN /BUILD CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ALL DEVICES, INCLUDING BUT NOT LIMITED �� SIDEWA _ O eep pg nCy/L0• TO: STROBES, ANNUNCIATERS AND EGRESS LIGHTING, REQUIRED BY ALL APPLICABLE CODES. POWER AND LIGHTING ALK 1 + ► —� DE �, . b � 0 DRAWINGS INCLUDED IN THIS DOCUMENT ARE FOR DESIGN PURPOSES ONLY. ANY DEVICE REQUIRED BY CODE OR BY Co n s trllet iQn Type „ es CALFDESIGNAND NOT CTOR'S S EXPENSEECTRICAL DESIGN /BUILDERS BASE BID SHALL BE INSTALLED AT THE The Mann , • , ,or / a / ,.e. ode / M _ .� bil GENERAL NOTES EXIT PATH TO :,�Ing PUBLIC WAY Eleet - - -•� • 1. ALL MATERIALS AND WORKMANSHIP SHALL COMPLY WITH THE 2003 INTERNATIONAL BUILDING CODE, THE AMERICANS MISS ngin, WITH DISABILITIES ACT, AND ALL STATE, COUNTY OR LOCAL REGULATIONS. Sh Drawings 2. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, MATERIAL SAMPLES AND COLOR DRAW DOWNS FOR DESIGNER REVIEW Other PRIOR TO CONSTRUCTION. SHOP DRAWINGS AND BIDDER DESIGN WORK SHALL REVIEWED FOR DESIGN INTENT ONLY. N 5.02.06 EXITING PLAN A0.0 SCALE: 1" = 20' COVER SHEET I / +/- 11' -3" _ +/- 22' -0" / (ALIGN WALL W/ EXISTING) , KEY NOTES I NOTE: (E) INDICATES EXISTING CONSTRUCTION. (N) I INDICATES NEW CONSTRUCTION. ALL NOTES ARE FOR NEW WORK UNLESS OTHERWISE NOTED I STORAGE STORAGE 153 SQ. FT. 118 SQ. FT. 1. ALIGN FACE OF (N)WALL W FACE OF (E)WALL N 2. 3' -0" X 7' -0' S.C. DOOR ASSEMBLY I 3. PAIR OF 3' -0" X 7' -0' S.C. DOORS - TYP. EXIST. MECH. RM. 2 EXIST. MECH. RM. 1 T __A__ (727 00 Ni,_ _, I �' C EXIST. ELEV. a EQUIP. RM. M WALL LEGEND EXISTING WALL CONSTRUCTION + TO REMAIN NEW 2 x 4 WD. STUD WALL EXIST. MEN 0 EXIST. EXIST. CONSTRUCTION W/ 5/8' GYP. 0 0 WOMEN ELEVATOR BD. EA. SIDE DESIGN CENTER SHOWROOM 1 627 SQ. FT. . L__J t__1 r L--- I1 [1_,-1 EXIST. CORRIDOR 40' i —1 �H ■ I 1 I 1 - ____.) 1 LI L _ _ J EXISTING TENANT IMPROVEMENT SPACE _ I E O I j, \ . .c.' X() . 0.NY AN. elyv n w _ 0 0. 5.02.06 , `' N A1.0 o � � �\ '.; V TENANT IMPROVEMENT FLOOR PLAN i 2 °Q064 SCALE: 1/8" = 1' — O" TENANT IMPROVEMENT