Loading...
Correspondence t'r August 12, 1996 , ..r fiSiO,l, i "i o Corili oi CITY OF TNG, " • Master Fire Control 11995 SE Hwy 212 O EGQ � Clackamas, OR 97015 RE: Twality Middle School Building Plan Review 14650 SW 97th PC #: 7 -47c BUP #: 96 -0416 Submittal documents for the above referenced project have been reviewed for conformance with the applicable 1996 Oregon Specialty Codes and other applicable codes and standards. The following comments are noted: iF'l Ex.$PtIVICL.ER. w =aI.. ., 3.,; ° n t1`'� Side -wall spray - sprinklers shall be installed in accordance with UBC, Std. G.. t y) e, There are rooms wider than 12 feet where you have specified a single branch line. Provide protection in accordance with Table 4- 4.2.1. B. The sprinkler layout in many rooms does not meet requirements for spacing, staggering, and distance to end wall specifications [UBC, Std. 9-1-4-4.2.1]. (See Typical C -23, C -26). Provide the sprinkler identification, specifications, and - number of sprinklers in the ���'�� sprinkler schedule on the plan. Pd. if [/3 • Protect all concealed combustible construction such as, but not limited to, soffits, � shafts, etc. r ‘ ', v , , i de prote ct i on fo • oo C- 5 and F -16. TO' ‘Lt y o ( U ; / 7 ( y I A Please sub three cope s of revis s documents and a letter indicating your V U' ' r response to th omments for review. Please call me at (503) 639 -4171 if you _ 1161 have any questions. c_ --L ....xi...A < Sincer lye, y Jim Funk` - -- `_.- 'PLANS EXAMINER , ,: is \cilywide\pc7- 47c .doc �y'��� • G A " �` j 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 MASTER FIRE CONTROL, INC. FIRE PROTECTION SPECIALISTS January 16. 1997 11995 S.E. HWY. 212 CLACKAMAS, ORE. 97015 Jim Funk PH.655 -6992 Plans Examiner City of Tigard 13125 SW Hall Blvd. Tigard, Oregon 97223 RE: Fire Sprinkler Plan Review of Twality Middle School Permit No. 96 -0416 This letter is in response to your plan review letter for Fire Sprinkler System remodel and addition dated August 12, 1996 and addresses the issues you brought up in your letter. 1.A. • ■ t_ e• for these rooms are in accordance with Table 4- ` 7.2 NFPA 13 1996 Edi' ion. e / us � y 1.B. The existing and new nstallation of sidewall sprinklers are in accordance with NFPA 13 1996 edition 4- 9.3.1.1 Exception No.2 and 4 -9.3.2 along with Table 4 -9.2 and Manufacturer Product Data sheets for Extended Coverage Horz S ewall (Included with this letter.). �yI 2. See attached copy of Title Block with list of all new sprinklers install in this remodel. We reused existing sidewalls that where removed from remodeled areas in the new additions. 3. Have complied. 4. These are existing rooms and at the time of the field servey I was unable to access these rooms. I have since been able to get into them and found them to be sprinklered. Please call if you have any questions. R- - •ec full 1/ / 0 40 K 4 lex Romno cc: Michael J. Watt, INC. • .Zittik CITY OF TIGARD OREGON January 21, 1997 Master Fire Control, Inc. 11995 S.E. Highway 212 Clackamas, OR 97015 RE: Twality Middle School Building Plan Review 14650 SW 97th PC #: 7 -47c B U P #: 96 -0416 Submittal documents for the above referenced project have been reviewed for conformance with the applicable 1996 Oregon Specialty Codes and other applicable codes and standards. The following comments are noted: In response to your letter of January 16, 1997, the following items need to be addressed: 4 The Oregon Revised Uniform Building Code Standard 9 -1 is based on NFPA 13, 1994, not 1996. Correct reference to the Standard. 2 Submit three (3) revised sets of plans, each containing the correct information in the title block. Please call m---a (503) 639 -4171 if you h. - any questions. ) Sincerely, 1 '� r s i- 1 ^' • , 3� ' fl Ai Id r Jim Funk il .4 U � e ' A, 72,j,e PLANS EXAMINER 3 o T: IPRMSYSDOCUMENT \BUP96_04.16TC7 -47C2 • • 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Mar -16 -98 07:07A M J Watt Inc. 503 236 0558 P.01 03/13/98 FRI 17:24 FAX 503 598 1980 CITY OF TIGARD [6001 • SkT tiNG TIE STANDARD FOR SER l<I E EXCELLENCE •I1' Facsimile To: Mike Kurilo, Project Manager Company: Michael J. Watt, Inc. Phone: 238 -0866 Fax: 236 -0558 From: Jean Heitschmidt, email: jean@ci.tigard.or.us Company: City of Tigard Building Division Phone: (503) 639 -4172, ext. 420 (5 :00 -11:00 pm) Fax: (503) 684 -7297 Date: March 13,1998 Pages including this page: 5 COMMENTS: I have received a copy of the inspection report for Twality Middle School that you faxed to on Hudson today. As you know, final approvals are not valid until the plans and permits are approved and issued by the Building Official. Your designer has not responded to the plan review letter; the plans have not been approved; the permit for fire protection (BUP96-0416) has not been issued; and the fee has not been paid ($128.63). In a conversation with you several months ago, you told me that the school district was picking up that permit and that it was not part of your contract. I have enclosed the leading edge of the plans for That work. It looks like you are the applicant rather than the school district. Without the fire protection permit, the related structural permits can't be approved. Please contact your subcontractor and resolve these issues as soon as possible. The School District is in violation of UBC standards and has been notified that the City and the Construction Contractor's Board have no choice but to penalize the applicants if final approvals are not received by March 31,1998. cc: Ron Hudson 15 V V6PccV City of Tigard, 13125 SW Hall Blvd h .r _ v� Mar -16 -98 07:O8A M J Watt Inc. 503 236 0558 P -04 03/13/98 FRI 17:26 FAX 503 598 1a8U Page No. 1. LOG NOTES FOR CASE NO.: BUP96 -0416 TIGARD TUALATIN SCHOOL DIST 14650 SW 97TH AVE 03/13/98 By Date Text of log note JT 12/02/97 The following information was data entered into description by Jim Funk April, 1997. It has been transferred to log notes for ease in reading:;; NOTE: continue this information throughout permits issued to Twality. Years ago, TVFR agreed to an alternate to requirements for fire protection of chases for mechanical installations, but unprotected voids were still allowed as density of .10 over 3,000 sq.ft. was provided. See NFPA 13. Most current is the understanding reached with Gene Birchill TVFR on 4/9/97 and Allen Crisanaz, PE for MRE & Assoc doing a mechanical up grade on the school. when opening a concealed comb void, draft and or fire stops will be installed. If the area is enlarged, it will be protected by the buildings fire suppression system. JT 12/02/97 a conversation i had with Jim Funk today. Jim stated hth tl for came into his office (some time ago) g if Jim this fire suppression permit. Jim stated yes, but permit had not been issued, Tom looked at plans and then went out and did an inspection. Jeanne T. • [\ 03/18/98 09:39 $`503 684 7297 CITY OF TIGARD 1J001 :1: :x: *: : :x : :$::::x ;$ :1:u :m:I::x *$x:I :$ *:s: ACTIVITY REPORT :s ** *********411-1.1.$1.1.1 ' ' 1 ' ' 1 ' ' ' ' ' ' '.k h: %f: TRANSMISSION OK TX/RX NO. 0549 CONNECTION TEL 503 656 0782 CONNECTION ID START TIME 03/18 09:37 USAGE TIME 02'01 PAGES 3 RESULT OK Post -it Fax Note 7671 Dale I f,d'Ify 1pagoes . To r//nv7[A From m / M CoJDept /T /� Av. Co. 7/ tr /q n Phone # Phone # f Fax #3--(/ ^ 6 3 _ 4 , C ; : 2 2 _ Fax # cS 4'4 "7 )` 1 -1.. ., CITY OF TIGARD OREGON . January 21, 1997 Master Fire Control, Inc. 11995 S.E. Highway 212 Clackamas, OR 97015 RE: Twality Middle School Building Plan Review 14650 SW 97th PC #: 7-47e BUP #: 96 -0416 Submittal documents for the above referenced project have been reviewed for conformance with the applicable 1996 Oregon Specialty Codes and other applicable codes and standards. The following comments are noted: In response to your letter of January 16, 1997, the following items need to be addressed: 42 The Oregon Revised Uniform Building Code Standard 9 -1 is based on NFPA 13, 1994, not 1996. Correct reference to the Standard. fip Submit three (3) revised sets of plans, each containing the correct information in the title block Please call m - (503) 639 -4171 if you h any questions. Sincerely, 1 )1 t t . _.,�_ . ,,/, Ai ,. 03/17/98 TUE 13:26 FAX 503 598 1960 CITY OF TIGARD U001 **** * ** *.* *** *** * ** * ** * ** TX REPORT * ** * * * * * * * * * * * * * * * * * * * ** TRANSMISSION OK TX /RX NO 0721 CONNECTION TEL 6560782 CONNECTION ID ST. TIME 03/17 13:25 USAGE T 00'41 PGS. SENT 1 RESULT OK CITY OF TIGARD OREGON January 21, 1997 Master Fire Control, Inc. 11995 S.E. Highway 212 Clackamas, OR 97015 RE: Twality Middle School Building Plan Review 14650 SW 97th PC #: 7 -47c BUP #: 96 -0416 Submittal documents for the above referenced project have been reviewed for conformance with the applicable 1996 Oregon Specialty Codes and other applicable codes and standards. The following comments are noted: In response to your letter of January 16, 1997, the following items need to be addressed: 1. The Oregon Revised Uniform Building Code Standard 9 -1 is based on NFPA 13, 1994, not 1996. Correct reference to the Standard. 2. Submit three (3) revised sets of plans, each containing the correct information in the title block. Please call me at (503) 639 -4171 if you have any questions. Sincerely, Jim Funk p `, ,S IN �qZ P n F T UALATIN VALLEY FIRE & RESCUE FIRE PREVENTION V ;` 4755 S.W. Griffith Drive . P.O. Box 4755 . Beaverton, OR 97076 . (503) 526 -2469 . FAX 526 -2538 u 'RF April 30, 1997 Jim Funk, Senior Plans Examiner i ) e City of Tigard Y g 13125 S.W. Hall Blvd. 9n T arcs, Oregon 97223 Re: Twality Junior High 14650 S.W. 97 Avenue 6189A- 003 -000 Dear Jim: Because of the history of sprinkling the above captioned facility, the fire district is willing to support a policy of not extending automatic sprinkler protection into existing void areas and concealed spaces unless those void areas and concealed spaces are made larger. This decision is based on the fact that the existing automatic sprinkler protection that is installed in the school is based on a .10 density with an application area of 3,000 square feet as prescribed in National Fire Protection Association Standard 13 when combustible concealed spaces are not provided with automatic sprinkler protection. The fire district is in support of providing automatic sprinkler protection in void and concealed spaces when void and concealed spaces are made larger or when extensive modifications are made to the building. This building was provided with automatic sprinkler protection during an extensive remodel where it was found that large continuous non -draft stopped/fire blocked void spaces were found running through the building. At that time a decision was made to ask the school district to provide automatic sprinkler protection in the building and the design criteria was chosen at that time. "Working" Smoke Detectors Save Lives Jim Funk April 30, 1997 Page 2 If there are any further questions, please call me at 526 -2469. Sincerely, Gene Birchill, DFM Plans Examiner GB:kw cc Ron Hudson Tigard School District Allen Crisanaz