Report Lic,3-6 9 - 7 q
r! Form 2a Project Name: Twality Middle School Interior Remodel Page:
SUMMARY
l r
Project 1. Project Twality Middle School Interior Remodel
2. Project Address 14650 SW 97th
3. City /Town Tigard 5. County Washington
4. Building, Gross Area (ft 4,080 6. No. of floors 1
Chapter Type ID Description Attached
Attached Building Envelope Form 3a Building Envelope - General ❑
Forms and 3b Prescriptive Path - Zone 1 ❑
Worksheets 3c Prescriptive Path - Zone 2 ❑
check boxes to ❑
indicate attached 3d Simplified Trade -off (use CodeComp software)
forms and Worksheet 3a Wall U- factors ❑
worksheets
3b Roof U- factors ❑
3c Floor U- factors ❑
Systems Form 4a Systems - General ❑
4b Complex Systems ❑
Worksheet 4a Unitary Air Conditioners - Air Cooled ❑
4b Unitary Air Conditioners - Water Cooled ❑
4c Unitary Heat Pump - Air Cooled ❑
4d Unitary Heat Pump - Water Cooled ❑
4e Unitary AC & Heat Pump - Evaporatively Cooled ❑
4f Packaged Terminal Air Conditioner - Air Cooled ❑
4g Packaged Terminal Heat Pump - Air Cooled ❑
4h Water Chilling Packages - Water and Air Cooled ❑
4i Boiler - Gas -fired & Oil -fired ❑
4j Furnaces and Unit Heaters - Gas and Oil -fired ❑
Lighting Form 5a Lighting - General 0
5b Interior Lighting Power - Occupancy Method
5c Interior Lighting Power - Space -by -Space Method ❑
Worksheet 5a Interior Lighting Power
5b Lighting Schedule
5c Interior Control Credits
Applicant 7. Name 10. Telephone
8. Company 11. Date
9. Signature
Attached No of Pages Description of Document
Documen-
tation
t..
Fnrm 2a 7104C Or_Energy_Forms_2000.xIs 05 -05 -2003
r '
Form 5a Project Name: Twality Middle School interior Remodel Page: 2.
LIGHTING - GENERAL
1
Y
1. Interior Exceptions (Section 1316.1)
Exceptions ❑ No Interior Lighting. The building plans and specifications do not call for new or
Discussion of qualifying altered interior lighting. Skip to item 4, Exterior building Lighting - General, below.
exceptions on page 5 -7. ❑ Exception. The building or part of the building qualifies for an exception from
code lighting requirements. The applicable code exception is Section:
Exception(s)
2. Local Shut - off controls (Section 1316.1.2.1,1)
El Complies. At least one local shut -off lighting control for every 2,000 square feet of
Exceptions lighted floor area and for all spaces enclosed by walls or ceiling height partitions.
Discussion of qualifying This control(s) is detailed in the building plans on drawing number: E2.2
exceptions on page 5 -8. ❑ Exception. The building or part of the building qualifies for an exception. The
applicable code code exception is Section 1316.1.2.1.1, Exception:
Portions of the building that qualify:
3. Office Controls (Section 1316.1.2.1,2)
Exceptions l] Not Applicable. Contiguous office floor area is not over 2,000 square feet.
Discussion of qualifying ❑ Complies. All interior lighting systems are equipped with a separate automatic
exceptions on page 5 -9. control to shut off the lighting and local override switching. These control(s) are
A detailed in the building plans on drawing number. .
❑ Exception. The building or part of the building qualifies for an exception. The
applicable code exception is Section 1316.1.2.1,2, Exception: _
Portions of the building that qualify:
4. Exterior Building Lighting - General
Definition ❑ No Exterior Building Lighting. Skip the rest of this form.
EXTERIOR o Complies. Complete items 5 and 6 below.
BUILDING LIGHTING
illlminah exterior e exter ior
illuminate e the 5. Exterior Building Lighting Controls (Section 1316.1.2.2)
of the building and 0 Complies. The building plans require that all exterior building lighting is equipped
adjacent walkways
and loading areas with automatic controls described in Sec. 1316.1.2.2. These controls are detailed
with or without
canopies. in the building plans on drawing number. E2.1 (existing timeclock controlled relays)
❑ Exception. The exterior building lighting is intended for 24 -hour continuous use.
6. Exterior Building Lighting Power (Section 1316.2.2)
El Complies. The plans do not call for incandescent lamps greater than 10 Watts
for use in exterior building lighting.
❑ Exception. The building plans indicate luminaires with incandescent lamps greater
than 10 Watts, but they are 5 percent or less of the total installed exterior lamps.
Total number of exterior lights:
Total number of exterior incandescent lights:
3 ,_ .\\,...,..,..
. . ,
. . .
, ,
4.
7104C Or Enerav Forms 2000.xls 05 -05 -2003
' Form 5b Project Name: Twality Middle School Interior Remodel Page: 2
INTERIOR LIGHTING POWER - Occupancy Method
Lighting (a) (b) (c) (d) (e) (f)
Budget Ceiling Floor Area Max Power Lighting
Group Occupancy Use Height (sq ft) Density Power Budget
(W /sq ft) (W )
Retail or Retail lighting, department stores, drug
Merchandise M stores, markets, etc. Any varies -
(Group M only)
— — -- under 15ft 1.2 -
E 1 II Educational occupancies K -12 V
Other occupancy — — — - - - - - -- 15ft or more 4,255 1.5 6,383
Use Types l
See page 5 -11 for I B -, — — ‘' under 15ft n/a -
instructions _
— — — — -- 15ft or more n/a
I under 15ft n/a
-
E IV V
I - -- 15ft or more n/a -
- - — — -- under 15ft n/a -
IF 'V 1
— 15ft or more n/a
I — — —._ — — under 15ft n/a -
H I - V
— — - - -- 15ft or more n/a -
I -- — — - -- - - - - -- under 15ft n/a -
I V w
I -- - - - - -- 15ft or more n/a =
- under 15ft n/a
R - — — -- - -� 15ft or more n/a -
I 1. Total Interior Lighting Power Budget (Watts) for building. 6,383
Track 2. Total length of track lighting (ft) 0
Lighting 3. Line 2 multiplied by 37.5 Watts /ft 0
Power 4. Total amperage of circuit breaker(s) serving track lighting (amps) 0
5. Voltage of circuit breaker serving track lighting (volts) 0
6. Wattage of circuit breaker serving track lighting (line 4 x line 5) 0
7. Track Lighting Power (lesser value of line 3 or line 6) -
i
Building's 8. Track Lighting Power (line 7) -
Lighting 9 Total Interior Lighting Power from Worksheet 5b + 7,376
Power 10. Total Control Credit from Worksheet 5c - 1,475
11. Total Adjusted Lighting Power = 5,901
(line 8 + line 9 - line 10)
12. Does design meet budget? Line 11 must be no greater than line 1. YES
F
L 'S Z
4---
r...... nh 71040 Or Enemy Forms 2000.xls 05 -05 -2003
Worksheet 5a Project Name: Twality Middle School Interior Remodel Page: L
LIGHTING SCHEDULE
ID is the ( (b) ( c ) (e)
identification I Type Lam W
number or letter Yp P / Ballast Description Power _ _ p ( ) _
used in your plans A M Halide HID V 1-MH400 1 -MAG STD
or specification i ° 461
v I' Wattage
* Enter the number and type of lamps V V Wattage
in the luminaire.
See Table 5b for V _ — _ _i V Wattage
typical lamp codes v O Wattage
** Enter the V _ V Wattage
number and type of ---
ballasts in the -- -- _ ___ _ —__ -- -- — _— ° Wattage
luminaire. For Wattage
fluorescent and - — .
high intensity V V Wattage
discharge lamps, — -
typical V 4 r Wattage
abbreviations are: —
V _ ® Wattage
MAG STD for
Magnetic Standard Wattage
V V Wattage
MAG EE for Energy r — — - -- — — — -- —
Efficient Magnetic V ' V Wattage
ELECT for V V Wattage
Electronic V 1 r Wattage
_ See Table 5b for 'V i YS J � =m � 1 . Wattage
other ballast - - - -" — ----- _ - — -
abbreviations j 1 r Wattage
VI I V Wattage
V V Wattage
-- - --- - -- - -- - - - - - --
- IF Wattage
- - - - --
er V Wattage
1r V Wattage
— — l- - ------- - - - - -- — f Wattage
— — — — — e Wattage
■ -- - -- . - -- - - [ ® Wattage
— --- ------- — - — -- -- --- -- Wattage
User Defined Fixtures - Cut Sheets must be included to verify wattage of complete luminaire
ID Fixture and Lamp Description Power
\\W
\ A/nrlechoaf Sa 7104C Or Energy Forms 2000.xls 05 -05 -2003
Worksheet 5b Project Name: Twality Middle School Interior Remodel Page: 5
INTERIOR LIGHTING POWER Worksheet No 5b -1
* Enter the (a) (b) ( C) (d) (e) (f)
quantity for every
non - exempt Room or Quantity of Luminaire Lighting Power
luminaire. Do not
consider track Sheet No. Room or Plans Designation Luminaire ID Luminaires* Power (Watts) (d) x (e)
lighting on this
E2.2 Gymnasium Lighting Plan IA V 16 461 7,376
worksheet. Track
lighting is 1 v 0 0
accounted for on v
Form 5b 0 0
v 0 0
Additional i --
pages may be 1 1 V 0 0
necessary if
building has more v 0 0
rooms than there V
are lines in this _ 0 0
form V 0 0
I v 0 0
I Div 0 0
v 0 0
i Iv 0 0
H 0 0
v 0' 0
v 0 0
0 0
_
Iv 0 0
iv 0 0
v 0 0
0 0
I 0 0
I v 0 0
v 0 0
I 0 0
v 0 0
TV
0 0
H 0 0
IF YOU DO NOT HAVE ENOUGH SPACE FOR ALL YOUR FIXTURES, USE ADDITIONAL PAGES RIGHT
• Worksheet 5b -1 Total 7,376
Other Pages o Description (optional) Worksheet Totals
List the additional Worksheet No. P (P )
worksheets necessary 7,376
to catalog all 5b -1
luminaires in building 5b -2
5b -3 -
,y -
. 5h-4
its`` Total Interior Lighting Power (of all worksheets) 7,376
Worksheet No 5b -1
r -
7104C Or Enemy Forms 2000.xls 05 -05 -2003
f.
Worksheet 5c Project Name: Twality Middle School Interior Remodel Page: 6
INTERIOR CONTROL CREDITS if applicable
Definitions (a) (b) (c) (d) (e) (f)
# of Luminaire Power
LUMEN
MAINTENANCE Luminaires Power Control Code Adjustment Control Credit
CONTROL Room or Plans Designation w /Controls (Watts) i (see below) Factor (b) x (c) x (e)
A device capable of Gymnasium Lighting Plan 16 461 Ms V 0.20 1,475.2
maintaining a preset '
SS
illumination level by 0 0 0.10 0.0
automatically 0 0 ss I V 0.10 0.0
adjusting the
luminaire power. 0 0 I ss I V 0.10 0.0
DAYLIGHT SENSING 0 0 SS V 0.10 0.0
CONTROL 0 0 ss V 0.10 0.0
A device that 0 0 ss 0.10 0.0
automatically adjusts
the power input to 0 0 ss - 0.10 0.0
electric lighting near
windows to maintain 0 0 ss v 0.10 0.0
desired workplace
illumination, taking 0 0 SS w 0.10 0.0
advantage of daylight. 0 0 I SS V 0.10 0.0
Should be capable of
reducing electric 0 0 ss V 0.10 0.0
power to 50 percent
or less of maximum 0 0 SS V 0.10 0.0
power. Three typical 0 0 SS I 0.10 0.0
types of daylight
sensing controls are: 0 0 I ss I V 0.10 0.0
Single- stepped 0 0 SS I V 0.10 0.0
control - Automatically
turns a light on or off 0 0 j SS � V 0.10 _ 0.0
when daylight levels
exceed lighting 0 0 SS v 0.10 0.0
requirements SS I
0 0 0.10 0.0
Multi- stepped 0 0 ss 1 - 0.10 0.0
dimming - Dims light
in discrete steps. For 0 0 SS V 0.10 0.0
example, dims light I by 25 percent, 50 0 0 I SS v 1 0.10 0.0
percent, 75 percent 0 Q Ss v 0.10 0.0
and off.
0 0 Ss 1 0.1 0 0.0
Continuous dimming - 1
Dims light in a 0 0 I SS v 0.10 0
continuous fashion
0 0 nss V i 0.10 0.0
0 0 ss V , 0.10 0.0
0 0 ss I - 0.10 0.0
1. Total Control Credits (Watts) 1,475
Power Automatic Lighting Control Control Code Power Adjustment Factor
Adjustment Single -Step On /Off Dimming SS 0.10
Factors Daylight Sensing Multiple Stepped Dimming MS 0.20
Continuous Dimming CD 0.30
Lumen Maintenance LM 0.10
r
,,,,...1........... Ge. 71n4C. flr Fnernv Fnrms 2000 xIs 05 -05 -2003