January 29, 2004 ' 14.
CITY OF TIGARD
OREGON
Brian Greenwood
Dull Olson Weekes Architects
319 SW Washington Street #200
Portland, OR 97204
RE: SITE WORK FOR EXISTING MIDDLE SCHOOL
Project Information
Site Permit: SIT2003 -00037 Construction Type: VN
Tenant Name: Twality Occupancy Type: E -1
Address: 14650 SW 97 Avenue Occupant Load: NA
Area: 5,180 Sq Ft Stories: 1
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC)
1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999
edition. The submitted plans are approved subject to the following.
EROSION
• Erosion control measures shall be in place prior to excavation or grading.
FIRE
• The private fire service main shall be at least 30 inches below grade.
• The private fire service main shall be flushed thoroughly before connection to the
system riser in order to remove foreign materials that might have entered the main
during the course the installation. The flow rate shall not be less than the water
demand rate of the system.
• All piping shall be inspected prior to backfill.
ACCESSIBILITY
• Accessible walkways and routes shall not exceed a running slope of 1 unit vertical in
20 units horizontal (5% slope). Cross slopes shall not exceed 1 unit vertical in 50
units horizontal (2% slope).
• Accessible parking spaces and access aisles shall be located on a surface with a slope
not to exceed 1 unit vertical in 50 units horizontal in all directions. 1104.4.3 OSSC
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall
be maintained on the jobsite. The plans shall be available to the Building Division inspectors
throughout all phases of construction. 106.4.2 OSSC
American with Disabilities Act (ADA): It shall be the responsibility of the Architect,
Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA
requirements for the structure. The City of Tigard reviews the plans and inspects the structure
only for compliance with Chapter 11 of the OSSC which may not include all of the
requirements of the ADA.
Premises Identification: Approved numbers or addresses shall be provided for all new
buildings in such a position as to be plainly visible and legible from the street or road
fronting the property.
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter o ransmittal. The letter of transmittal assists the City of
Tigard in tracking and proce :'1iYlhe documents.
Respect y
rianB ; ,
Senio -• ' Tans Ex. er
DEC -09 -2004 11:51 SJO CONSULTING ENGINEERS P.003
15575 SW SCquoirf ,,--/ T2e03 -Ova' 3 7
Parkway Suite 14
PpNfpnd. 011 97224
P-Oac v 77 , t A , . . _ .
SW
CONSULTING
ENGINEERS, INC
December 9, 2004
City of Tigard
13125 SW Hall Blvd
Tigard, OR 97223 FILE COPY
Attn: Hap Watkins
Building Division .
Re: Twality Middle School Renovation Project Stormwater Facilities
MMD2003 -00017
Dear Hap:
The engineering design for stormwater quality at Twality Middle School incorporated two (2)
filter catch basins manufactured by Stormwater Management, Inc. Detention was provided
by a small surface pond and a flow control manhole. I visited the site at various stages of
construction and confirm that the installation of the quality and detention facilities are in
conformance with the design and specifications.
Sincerely,
if /IF
/MP ' 1
Mark Wharry, P.E.
Principal
cc: Brian Greenwood / DOWA
Nick Harris / Cornerstone
0:12401 TTSD- Twality \DOCS\LETTER \120904hw.wpd
503/226-3921
f ax:226 - 3926
TOTAL P.003