Correspondence July 31, 2003 X CITY • FF TIG :: ._F; OREGON Jackie Root Zaik/Miller Associates 2340 NW Thurman, Suite 201 Portland, OR 97210 RE: SITEWORK @ TIGARD CHURCH OF GOD Project Information Site Permit: SIT2003 -00020 Construction Type: VN Tenant Name: Tigard Church of God Occupancy Type: B Address: 15750 SW 98 Avenue Occupant Load: NA Area: 2,875 Sq Ft Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The plans are approved subject to the following: EROSION • Erosion control measures shall be in place prior to excavation or grading. ACCESSIBILITY • Accessible walkways and routes shall not exceed a running slope of 1 unit vertical in 20 units horizontal (5% slope). Cross slopes shall not exceed 1 unit vertical in 50 units horizontal (2% slope). • Accessible parking spaces, access aisles and accessible route to public way shall be indicated on sheet AO Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of instruction. 106.4.2 OSSC Respect • Ian : ock, • Senior Plans Examiner 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 4,004 II I��illlj (I �\ July 31, 2003 CITY OF TIGARD OREGON Jackie Root Zaik/Miller Associates 2340 NW Thurman, Suite 201 Portland, OR 97210 Y:. RE: SITEWORK @ TIGARD CHURCH OF GOD Project Information Site Permit: SIT2003 -00020 Construction Type: VN Tenant Name: Tigard Church of God Occupancy Type: B Address: 15750 SW 98 Avenue Occupant Load: NA Area: 2,875 Sq Ft Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The plans are approved subject to the following: EROSION • • Erosion control measures shall be in place prior to excavation or grading. ACCESSIBILITY • Accessible walkways and routes shall not exceed a running slope of 1 unit vertical in 20 units horizontal (5% slope). Cross slopes shall not exceed 1 unit vertical in 50 units horizontal (2% slope). • Accessible parking spaces, access aisles and accessible route to public way shall be indicated on sheet AO Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC Respec y, Bria aloe , Se , Plans Examiner 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 July 28, 2003 ����0 V �i ITY OF TIGARD JUL 3 0 2003 OREGON Jackie Root Zaik/Miller Associates CITY OF TIGAHU 2340 NW Thurman, Suite 201 BUILDING DIVISION Portland, OR 97210 RE: SITEWORK @ TIGARD CHURCH OF GOD Project Information Site Permit: SIT2003 -00020 Construction Type: VN Tenant Name: Tigard Church of God Occupancy Type: B Address: 15670 SW 98 Avenue Occupant Load: NA Area: 2,875 Sq Ft Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The following information is required prior to the issuance of a Site Permit: EXCAVATION 1. The foundation plan has used an allowable soil.bearing pressure of 2500 per square foot (psf). Provide a soils report to justify psf loading. FIRE REVIEW 2. Complete the enclosed "TVF &R FIRE FLOW and HYDRANT WORKSHEET ". The allowable area permitted and the number of hydrants required will be based on the worksheet. ACCESSIBILITY 3. Clarify the accessible route to the public way as required by section 1103.1 OSSC. 4. Clarify the detectable warnings that will be provided when the accessible route crosses a vehicular way. See section 1103.2.3.2 OSSC 5. Accessible parking and access aisles appear on the South side of the Administration Building, on sheet Cl I think. They are not identified. Provide curb cut type ramps or any other method approved by the code for accessible access aisle. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 6. Identify the accessible route from the access aisle on the plans including landings. Accessible walkways and routes shall not exceed a running slope of 1 unit vertical in 20 units horizontal (5% slope). Cross slopes shall not exceed 1 unit vertical in 50 units horizontal (2% slope). 1103.2.4.3 OSSC 7. Provide a detail for an accessible parking sign and clarify the location. FYI, the bottom of the sign is required to be 84 inches form grade. FYI The plans do not indicate a connection to the sanitary sewer? The Plumbing Code does not permit plumbing pipes to run parallel to a foundation footing if they are in the zone of influence of the footing. The Sanitary and Storm Sewer are close to the footing in a couple of places and depth is not indicated. Please provide an item by item response. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectful , ria f alock, S i or Plans Examiner