Report Seattle Office MAYES TESTING ENGINEERS, INC. V Lymnnod, WA 98036 ph 425.7429360 fax 425.745.1737 Tacama Office 10029 S. Taxma Wad March 9, 2011 SrieE2 Tacoma, WA 98499 01 253.554.3720 City of Tigard kx253.584.3707 Building Official R„tta,d Office 13125 SW Hall Blvd 7911 NE 33rd Owe Tigard, OR 97223 Suite 190 Portland, OR 97211 ph 5032817515 fax 5032817579 RE: FINAL SUMMARY REPORT Auto Zone #3756 Tigard 13405 SW Pacific Highway Tigard, OR Permit No.: BUP 2010 - 00169, BUP 2010 -00215 (Racking) Project No. P10191 Gentlemen: This is to certify that in accordance with Section 1701 of the State Building Code, we have performed special inspection on the below listed items per our daily reports, copies of which have been sent to you. Reinforced Concrete Expansion Anchor Structural Steel Erection and Welding Structural Masonry To the best of our knowledge all work inspected was performed in accordance with, or corrected to conform to, the approved drawings or engineer approved changes and in conformance with the applicable workmanship provisions of the State Building Code and Standards. Respectfully, MAYES TESTING ENGINEERS, INC. • MAYES TESTING ENGINEERS, INC Seat* Office 20225 Cedar yRoa t ""s4 _, rt Suite 110 Lynnwood, WA 98036 ph 425 742 9360 fax 425.745.1737 Project No. P10191 Project AutoZone #3756 Tigard Tacoma 1CO29 S Address 13405 SW Pacific Highway, Tigard, OR SuiieE -2 Permit No. BUP 2010 -00215 Tacoma, WA 99 Bldg Dept. City of Tigard ph 253.584.3720 g P Y 9 fax 253 584.3707 Owner AutoZone Portland Office Engineer Wallace Engineering �190 oie Contractor Corstone Contractors, LLC Portland, OR 97211 ph 503281.7515 fax 503281.7579 Record No. 017 Date March 10, 2011 Weather Indoors Inspection Expansion Anchor Sample(s) none Inspected installed HILTI KB -TZ 3/8 "x3" expansion anchors installed for seismic anchorage of storage racks per drawing sheets 10 -1046 through 10 -1046D (Seizmic Engineering, 09/13/10). Installed storage racks are designated types: A, Al, B, B1, Cl, D, E, G, H, I, K, L and M per sheet 10 -1046A (Seizmic Engineering). Installed anchors were verified to proper installation torque (25 ft lbs per manufacturer) with MTE calibrated torque wrench ( #P385, calibrated 08/20/10). Locations and quantities of installed anchors per drawings. Inspected installed "X" brace strapping per 10 -1046C on type I shelving racks. Straps attached to storage rack framing with #8x3/4" screws per manufacturer's instructions. • 404 vv,r Typical installed strap bracing. Typical installed expansion anchor To the best of our knowledge, items inspected this date are in accordance with approved plans and specifications. Inspector: Aaron VanderPol OBOA # 983 Reviewed by: Page 1 of 1