RE: FINAL SUMMARY REPORT
Auto Zone #3756 Tigard
13405 SW Pacific Highway
Tigard, OR
Permit No.: BUP 2010 - 00169, BUP 2010 -00215 (Racking)
Project No. P10191
Gentlemen:
This is to certify that in accordance with Section 1701 of the State Building Code, we have
performed special inspection on the below listed items per our daily reports, copies of which have
been sent to you.
Reinforced Concrete
Expansion Anchor
Structural Steel Erection and Welding
Structural Masonry
To the best of our knowledge all work inspected was performed in accordance with, or corrected to
conform to, the approved drawings or engineer approved changes and in conformance with the
applicable workmanship provisions of the State Building Code and Standards.
Respectfully,
MAYES TESTING ENGINEERS, INC.
•
MAYES TESTING ENGINEERS, INC
Seat* Office
20225 Cedar yRoa
t ""s4 _, rt Suite 110
Lynnwood, WA 98036
ph 425 742 9360
fax 425.745.1737
Project No. P10191
Project AutoZone #3756 Tigard Tacoma 1CO29 S
Address 13405 SW Pacific Highway, Tigard, OR SuiieE -2
Permit No. BUP 2010 -00215 Tacoma, WA 99
Bldg Dept. City of Tigard ph 253.584.3720
g P Y 9 fax 253 584.3707
Owner AutoZone Portland Office
Engineer Wallace Engineering �190 oie
Contractor Corstone Contractors, LLC Portland, OR 97211
ph 503281.7515
fax 503281.7579
Record No. 017
Date March 10, 2011
Weather Indoors
Inspection Expansion Anchor
Sample(s) none
Inspected installed HILTI KB -TZ 3/8 "x3" expansion anchors installed for seismic anchorage of
storage racks per drawing sheets 10 -1046 through 10 -1046D (Seizmic Engineering, 09/13/10).
Installed storage racks are designated types: A, Al, B, B1, Cl, D, E, G, H, I, K, L and M per sheet
10 -1046A (Seizmic Engineering). Installed anchors were verified to proper installation torque (25 ft
lbs per manufacturer) with MTE calibrated torque wrench ( #P385, calibrated 08/20/10). Locations
and quantities of installed anchors per drawings.
Inspected installed "X" brace strapping per 10 -1046C on type I shelving racks. Straps attached to
storage rack framing with #8x3/4" screws per manufacturer's instructions.
•
404 vv,r
Typical installed strap bracing. Typical installed expansion anchor
To the best of our knowledge, items inspected this date are in accordance with approved plans and
specifications.
Inspector: Aaron VanderPol
OBOA # 983
Reviewed by:
Page 1 of 1