Loading...
Specifications y � FECEIVED IrtC ,2 0 V 7 60 7 SERIES R 2 2007 �oMMa, I C R_C� 2 ary OF TIGARD ' {, -c lLum DPJt6IO ommercial Package Gas /Electric Units Meets Ashrae 90.1 Standards FEATURES: - • Exclusive integrated gas control board with diagnostics Indu ;,d-draft fan for gas combustion aZ: • ,, bider, dimpled heat exchangers ■ Pre - painted galvanized steel cabinet for long life and quality appearance o o 0,,,.... • Commercial strength base rails with built -in rigging capability • Convertible design for vertical or horizontal supply /return • Non - corrosive, sloped condensate drain pan, meets ASHRAE 62 i a - °° • Two-inch return -air filters • High and low (loss -of- charge) pressure switches and freezestat PGE090, 120, 150 • Direct -spark ignition systems • Refrigerant filter drier • Part load operation using two stages of cooling • Quiet and efficient operation is provided by belt driven evaporator fans • Thru- the -bottom utility connection capability allow power, control wiring, and gas to be routed through unit base pan, minimizing roof penetrations. Warranty: 10 year Heat Exchanger, 5 year compressor, 1 year parts 7).-.14,... OF TIGARD Approved f T t tTnditlonally Approved F 3r only the wgrk. described in: f 1 `� j P59MIT NO. — 7 See �- y ee letter to: Follow 'rANnAg) 4 f I ,Q ,,,,00 To QT,,,,,, Attach Job Address: 0.730 SI JSr�I i i s ..„0 uq co, o` � S � , � ✓ - ----' A � /N. , Date: 0 1-2 -O 7 W j P '• , n C 1 )1. US i RAMst f C Arm-Crib t ® L � � f' _ E 'DWPMEN I • • .M 5 piCTd o NND vcRM.xT' 9r avr sci 3 '. 4 ■ ND�P0 P / vC 0 I RESIDENTIAL AND COMMERCIAL SYSTEMS • SPLIT SYSTEMS • PACKAGED AIR CONDITIONERS • COMBINATION GAS / ELECTRIC UNITS • HEAT PUMPS • AIR HANDLERS • MANUFACTURED HOME AIR CONDITIONERS • GAS, OIL AND ELECTRIC FURNACES International Comfort Products 650 Heil- Quaker Avenue, Lewisburg, TN 37091 509 71 2101 05 . OFFICE 6/23/03 Table of Contents Page Features /Benefits 1 Model Number Nomenclature 2 Unit Specifications 3 -4 Dimensions 5 Performance Data 6 -11 Typical Installation 12 Accessories 13 -16 Controls 17 Guide Specs 18 MODEL NUMBER IDENTIFICATION GUIDE MODEL NUMBER P G E 090 H 224 A PRODUCT FAMILY Package Units Sales Code TYPE GAS HEATING OPTIONS (BTUH) 224 = 224,000 250 = 250,000 H= Heat Pump G = Gas/Electric A = Air Conditioner VOLTAGE I PHASE / HERTZ H = 208/230 -3 -60 DESIGN SERIES L = 460 -3 -60 S = 575 -3 -60 ' COOLING CAPACITY (NOMINAL BTUH) 090 = 7 -1/2 120 = 10 Ton 150 = 12 -1/2 Ton • C ®L . 2 . UNIT SPECIFICATIONS (Legend on Next Page) MODELS COOLING PGE090H PGE090L L PGE090S PGE120H PGE120 " PGE120S PGE150H PGE150L PGE150S ARI Rated Capacity Btuh (Net) 87,000 0t0 136,000 Nominal Tons t Standard CFM 2800 •ttt tt EER t IPLV t 10.4 10.' 10.2 Sound Rating (Bels) Unit Weight (lbs. / kg) 870 t t ELECTRICAL - • I PGE090H I PGEO9OL I PGE090S I PGE120H I PGE120L I PGE120S I PGE150H I PGE150L I PGE15OS • 60Hertz 208/230 460 575 208/230 460 575 208/230 460 Voltage Range Min/Max 187 /254 414 /508 518 /632 187 /254 414 t: t: 518 /632 01 t t COMPRESSOR I RECIPROCATING ` I _ SCROLL I SCROLL -" .t ea RLA t t t •t 15.81130 .•t t .t •t tt t REFRIGERANT TYPE , R -22 Expansion Device Fixed Orifice Device CONDENSER FAN Propeller Type Nominal CFM 6400 ttt 7000 t• tt Watts Input (Total) 600 .tt 650 FLA 1.4 0.7 0.7 1.4 t t t t CONDENSER COIL Enhanced Copper Tubes, Aluminum Lanced fins ., t EVAPORATOR COIL Enhanced Copper Tubes, Aluminum Double Wavy Fins • Rows...Fins/Inch 3...15 3...15 • - Total Face (sq: ft.) •--- - - - - -- - -- ---- -8:9 -- — — 10.0 11.1 EVAPORATOR FAN Centrifugal Type Quantity...Size(in.) 1...15x15 1...15x15 1...15x15 Type Drive Belt Belt Belt Nominal CFM 3000 4000 5000 Max. Continuous Bhp 2.4 2.4 5.25 FLA- 208- 230/460/575V 5.8/2.6/2.6 5.8/2.6/2.6 15.0/7.4/7.4 Motor Frame Size 56 56 56 Fan RPM Range 590 -840 685 -935 900 -1260 Motor Bearing Ball Ball Ball Maximum Allowable RPM 2100 2100 2100 Motor Pulley Pitch / Diameter Min /Max. (in.) 2.4 / 3.4 2.8 / 3.8 _ 2.8 / 3.8 Motor Shaft Diameter (in.) 5/8 5/8 7/8 Fan Pulley Pitch Diam (in) 7.0 7.0 • 8.0 Belt, Quantitiy...Type... Length (in.) 1...A...49 1...A...49 1...A...52 Pulley Center Line Distance (in) 16.75 -19.25 15.85 -17.50 15.85 -17.50 Speed Change per Full Turn of Movable Pulley 50 50 60 Flange (RPM) Pulley Max. full Turns From Closed Postion 5 5 6 Factory Setting 5 5 5 Factory Speed Setting RPM 590 685 960 Fan Shaft Diam. at Pulley 1 1 1 3 • UNIT SPECIFICATIONS (CONT) MODELS FURNACE SECTION i PGE090 - I PGE120 PGE150 Rollout Switch Cutout Temp (F) 195 195 195 Burner Orifice Diameter (in. .drill size) Natural Gas 120...31 129...30 129...30 Liquid Propane 096...41 102...38 102...38 Thermostat Heat Anticipator Setting (amps) 208/230 v and 575v Stage 1 14 14 14 208/230 v and 575v Stage 2 20 20 20 460 v Stage 1 14 14 14 460 v Stage 2 20 20 20 Gas Input (Btuh) Stage 2 / Stage 1 224,000 / 180,000 250,000 / 200,000 250,000 / 200,000 -- Output.Capacity.(Btuh).- ____- -__ -__ __.__ - - -._— — 1-79,200 - - -- - - -. - 200,-000 -- -• -- — 200;000 - - - - -- - Efficiency (Steady State) ( %) AFUE 80 80 80 Temperature Rise Range 45 -75 40 -70 40 -70 Manifold Pressure (in. wg) Natural Gas 3.5 3.5 3.5 Liquid Propane 3.5 3.5 3.5 Gas Valve Quantity 1 1 1 Gas Valve Pressure Range Psig . 0.180 -0.487 0.180 -0.487 0.180 -0.487 in. wg 5.0 -13.5 5.0 -13.5 5.0 -13.5 Field Gas Connection Size (in.) 3/4 3/4 3/4 HIGH PRESSURE SWITCH (psig • . Standard Compressor 450 +/- 50 450 +/- 50 450 +/- 50 Internal Relief (Differential) Cutout 428 428 428 Reset (Auto.) 320 320 320 LOSS - OF - CHARGE SWITCH (psig) (LOW - PRESS.) • Cutout 7 +l- 3 7 +/- 3 7 +/- 3 Reset (Auto.) 22 +/- 7 22 +l- 7 22 +/- 7 FREEZE PROTECTION THERM OSTAT (F) . Opens 30 +/- 5 30 +l- 5 30 +/- 5 Closes 45 +/- 5 45 +1- 5 45 +/- 5 • - RETURN - AIR FILTERS (THROWAWAY) , _ Quantity...Size(in.) 4...16x20x2 • 4...20x20x2 4...20x20x2 LEGENDS AND NOTES Bhp = Brake Horsepower NOTES: 1. Rated in accordance with ARI Standards 210/240, latest revision (for sizes 090 & 120) or 360, latest revision (for size Legend 150). Bets - Sound Levels 2. ARI ratings are net values, reflecting the effects of circulating EER - Energy Efficiency Ratio fan heat. IPLV - Integrated Part Load Values 3. Ratings are based on: MCA - Minimum Circuit Amps Cooling Standard: 80F db, 67F wb indoor entering air MOCP - Maximum Over- current Protection temperture and 95F db air entering outdoor unit. FLA - Full Load Amps IPLV Standard: 80F db, 67F wb indoor entering air temperture LRA - Locked Rotor Amps and 80F db entering air temperature. Fuse or HACR circuit breaker EXAMPLE: Supply voltage is 460 -3 -60. RLA - Rated Load Amps A B C AB = 452 v Average Voltage = 452 + 464 + 455 Fl BC = 464 v = 3 AC = 455 v 1371 3 NOTES: MOTOR = 457 1. In compliance with NEC requirements for multimotor and combina- Determine maximum deviation from average voltage. tion load equipment (refer to NEC Articles 430 and 440), the over- (AB) 457 - 452 = 5 V current protective device for the unit shall be fuse or HACR breaker . (BC) 464 - 457 = 7 V ■ Canadian units may be fuse or circuit breaker . (AB) 457 - 455 = 2 V 2. Unbalanced 3 -Phase Supply Voltage Maximum deviation is 7 v. Never operate a motor where a phase imbalance in supply voltage is greater than 2 %. Use the following formula to determine the percent Determine percent voltage imbalance. voltage imbalance. % Voltage Imbalance 100 x 7 = 1.53% Voltage Imbalance 457 = 100 x max voltage deviation from average voltage This amount of phase imbalance is satisfactory as it is below the average voltage maximum allowable 2 %. IMPORTANT: If the supply voltage phase imbalance is more than 2 %, contact your local electric utility company immediately . 4