Correspondence Dec.16. 2004 3:19PM No.8356 P. 5 December 15, 2004' "''�'� + "91�iIM1��'►' cirr OF TIGARD OREGON EEA Architects, PC 1230 SW First Avenue, Suite 300 Portland, OR 97204 RE: ALBERTA RIDER ELEMENTARY, 2ND REVIEW Project Information Site Permit: SIT2004 -00029 Construction Type: H - 1BR Tenant Name: Alberta Rider Elementary Occupancy Type: E- 1,A2.1, B, S -1 Address: 14850 SW 132nd Terrace Occupant Load: NA Area: 67,500 Sq Ft Stories: 2 • The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition, and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99- 01) 1999 edition. The following information is required prior to the issuance of a Site Permit: EXCAVATION 1. Complete the enclosed permit application clarifying the Excavation, Grading and Fill volumes. RESPONSE ACCEPTED 12/14/04 2. Clarify the new impervious area. Impervious is defined as building roof areas, sidewalks and paving. The number should be what is new impervious as related to what was existing. RESPONSE ACCEPTED 12/14/04 FIRE REVIEW 3. Complete the enclosed "TVF &R FIRE FLOW and HYDRANT WORKSHEET ". The allowable area permitted and the number of hydrants required will be based on the worksheet. - A 06.6 P1 / - /5 .-,6 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639- 4171PfSIDk503) 684 -2772 Dec.16. 2004 3:19PM No.8356 P. 6 4. Underground Fire Fighting Water Supply. Provide piping sizes and materials, valve equipment cut sheets. All valves shall be listed for use in a fire service application. RESPONSE NOT PROVIDED ACCESSIBILITY 5. Clarify the accessible route to the public way as required by section 1103.1 OSSC. Please indicate slope on the plans. RESPONSE NOT PROVIDED 6. Clarify the detectable warnings that will be provided when the accessible route crosses a vehicular way. See section 1103.2.3.2 OSSC RESPONSE NOT PROVIDED 7. Clarify the total accessible parking as shown on plan page C2.3 = 79 spaces, required minimum number of accessible spaces should be 4. RESPONSE NOT PROVIDED 8. Clarify that Accessible parking access aisles are located on the passenger side of the parking space except that two adjacent accessible parking spaces may share a common access aisle. ORS 447.233, 1104.1 RESPONSE NOT PROVIDED NOTE: Please remember when submitting information to use the enclosed City of Tigard, Letter of Transmittal and provide an item by item response. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents_ Respectfully al Henzel, Senior Plans Examiner Page 2 12/15/2004 t December 15, 2004 CITY OF TIGARD OREGON EEA Architects, PC 1230 SW First Avenue, Suite 300 Portland, OR 97204 RE: ALBERTA RIDER ELEMENTARY, 2 REVIEW Project Information Site Permit: SIT2004 -00029 Construction Type: II - 1HR Tenant Name: Alberta Rider Elementary Occupancy Type: E- 1,A2.1, B, S -1 Address: 14850 SW 132nd Terrace Occupant Load: NA Area: 67,500 Sq Ft Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99- 01) 1999 edition. The following information is required prior to the issuance of a Site Permit: EXCAVATION 1. Complete the enclosed permit application clarifying the Excavation, Grading and Fill volumes. RESPONSE ACCEPTED 12/14/04 2. Clarify the new impervious area. Impervious is defined as building roof areas, sidewalks and paving. The number should be what is new impervious as related to what was existing. RESPONSE ACCEPTED 12/14/04 FIRE REVIEW 3. Complete the enclosed "TVF &R FIRE FLOW and HYDRANT WORKSHEET ". The allowable area permitted and the number of hydrants required will be based on the worksheet. RESPONSE NOT PROVIDE (b\ 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 - 417101(503) 684 -2772 17/15/7004 4. Underground Fire Fighting Water Supply. Provide piping sizes and materials, valve equipment cut sheets. All valves shall be listed for use in a fire service application. Q (60' `(L RESPONSE NOT PROVIDED �..1 e� �C.•� � $ ev i ACCESSIBILITY 5. Clarify the accessible route to the public way as required by section 1103.1 OSSC. Please indicate slope on the plans. �"\ RESPONSE NOT PROVIDED K ) 6. Clarify the detectable that will be provided when the accessible route crosses a vehicular way. See section 1103.2.3.2 OSSC RESPONSE NOT PROVIDED \� `a� i 7. Clarify the total accessible parking as shown on plan page C2.3 = 79 spaces, required minimum number of accessible spaces should be 4. RESPONSE NOT PROVIDED \\,1((/ 8. Clarify that Accessible parking access aisles are located on the passenger side of the parking space except that two adjacent accessible parking spaces may share a common access aisle. ORS 447.233, 1104 \3.\i RESPONSE NOT PROVIDED NOTE: Please remember when submitting information to use the enclosed City of Tigard, Letter of Transmittal and provide an item by item response. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, 107:11 al Henzel, Senior Plans Examiner Page 2 12/15/2004 Susan Ross _Fwd: Alberta Rider Driveway _ Page 1 1 coif 62- / c f eso st.✓ t32No i - i From: Jim Hendryx To: Susan Ross Date: 05/19/2005 7:37:56 AM Subject: Fwd: Alberta Rider Driveway Would you draft up a letter to the School District identifying the process that must be followed. Work with Dick on the specific's Thank you Jim Hendryx Phone 503 639 -4171 ext. 2443 Direct dial 503 718 -2443 Fax 503 684 -7297 »> Dick Bewersdorff 5/17/2005 4:17:40 PM »> The Alberta Rider house driveway was decided as part of the Alberta Rider School application. That was a Type III Hearings Officer decision. We cannot modify that decision. No appeal was made so the decision is final. According to the development code under conditional uses a change in the type and /or location of access ways and parking areas where off -site traffic would be affected is a major modification (18.330.030 B. 2 c.). That means to modify the HO's decision requires a complete hearing process including pre -app, neighborhood meeting, application and hearing review by the HO. The problem with even considering it was the School District used the closing of the driveway in its argument for approval of their emergency access which is about 80 feet away. If the for the school is completed, the need for the emergency access will likely go away but there are separation issues even for the existing Alberta Rider driveways. The whole thing would be an adjustment to 18.705 H. Access Management standards which requires a 200 foot separation and I don't know how it can meet the standards. It looks like street access to the Alpine View subdivision across the street as well as single family home driveways may come into play also. It is possible that if the emergency access went away and the Alberta Rider driveways could be rebuilt to meet the separation standard on the Rider property but that does not take into account the streets or driveway across the street. To repeat the adjustment would be a major modification to the conditional use permit approved by the HO. Too much information I know! CC: Dick Bewersdorff 5 IT 2.60 -66029 1 t -t % 50 stn/ 1 3 Z /D t1 7.2 ri k ko■fintgaitt Thursday, November 10, 2005 TIG Stephen D. Poage OREGON Project Manager Tigard - Tualatin School District 6960 SW Sandburg St. Tigard, OR 97223 RE Citation and Penalties for Use or Occupancy Without Certificate of Occupancy. This responds to your question to Susan Ross of our office concerning our authority and basis for issuing a Summons and Complaint and seeking penalties of up to $250.00 per day, per violation, in cases of the use or occupancy of a structure, such as the Alberta Rider School, when it has not yet received a Certificate of Occupancy or the final inspection approval required for same. The 2004 Oregon Structural Specialty Code (OSSC) provides, in Section 110.1, that "No building or structure shall be used or occupied ... until the building official has issued a certificate of occupancy therefor as provided herein." OSSC 112.1 provides that "it shall be unlawful for any person, firm, or corporation to ... occupy any building, structure, or equipment regulated by this code, or cause same to be done, in conflict with or in violation of any of the provisions of this code." Tigard Municipal Code (TMC) Chapter 14.04.030 State Codes Adopted adopts the State codes, including the OSSC. TMC 14.04.090.1 provides that "no person shall ... occupy or maintain a building or structure in the City, or cause the same to be done, contrary to or in violation of this chapter." TMC 14.04.090.5 provides that "violation of a provision of this chapter constitutes a Class 1 civil infraction ..." and 14.04.090.6 provides that "each day that a violation of a provision of this chapter exists constitutes a separate violation." TMC 1.16.410 provides that "the civil penalty to be assessed for a specific infraction shall be as follows: 1. For Class 1 infractions, an amount not to exceed two hundred fifty dollars." Accordingly, if a structure such as the Alberta Rider School is put into use or is occupied prior to receiving a Certificate of Occupancy the City of Tigard may issue a Summons and Complaint for the occupancy violation and seek an award of penalties up to $250.00 per day, per violation. Please be advised that it is our general policy and practice to serve such Summonses and seek such penalties in cases where the potential violation and penalties have been explicitly discussed 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 and particularly in cases where a Temporary Certificate of Occupancy and Voluntary Compliance Agreement has been discussed or has been entered into and then violated. I am the City's Building Codes Enforcement Officer and it is my responsibility to serve such Summonses and seek such penalties in the appropriate circumstances. It is my understanding, however, that there should be no great difficulty in completing the outstanding items under BUP2004 -00529 within the thirty (30) day period of the proposed Temporary Certificate of Occupancy and Voluntary Compliance Agreement and, accordingly, I hope and expect that this discussion of the authority for citation and penalties will be purely academic and informational. If you have any questions about any of the above comments, please call me directly at 503- 718 -2426. I have attached copies of the OSSC sections referred to above. r Albert . ields Bu' I ing Codes Enforcement Officer cc: Tom Coffee, Gary Lampella, Hap Watkins, Susan Ross, Rob Saxton. • /Ouiuu�lA�(IO�III���bf �f September 1, 2005 CITY OF TIGARD OREGON Clean Water Services 255o S.W. Hillsboro Highway Hillsboro OR 91123 RE: Permit # 05- 000317 -00 -PE Alberta Rider Elementary School In working with the Tigard - Tualatin School District to begin finalizing the above - reference project, it was found that the District paid a Water Quantity SDC of $14,652.92 on your Permit # 05- 000317- 00 -PE, issued 2/15/05. The District also paid the Water Quantity SDC to the city of Tigard, Permit SIT 2004- 00029. I agreed to assist their representative in a solution to this double payment by contacting Clean Water Services and finding what your policy and role would be in making a refund to the Tigard- Tualatin School District of the Water Quantity SDC that was paid to you in March. Are there certain forms necessary to request a refund? Copies of both permits are attached and I look forward to hearing from you regarding this refund. Sincerely, ue Ross, Permit Coordinator City of Tigard cc: Stephen Poage, Tigard - Tualatin School District Gary Lampella, Building Official 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 CleanWater • Services Permit #: 05 - 000317 - 00 - PE • < co, `' " clear. Inspection Request Line: 503 - 681 -4444 2550 SW Hillsboro Highway hI 6 600 97123 P ► 4 hour notice required for all inspections Project Name: TI - ALBERTA RIDER ELEMENTARY • Project Address: 13040 SW BULL MOUNTAIN RD Issued By: Nichole Vanderzanden Type: Sani /SWM Connection Issued: Feb 16, 2005 Commercial Project Description: 14850 SW 132ND TERRACE Expires: Aug 15, 2005 • Owner Applicant NONE Contractor TIGARD- TUALATIN SCHOOL DIST 23J c/o P NONE 6960 SW SANDBURG ST TIGARD OR 97223 • Number of Equivalent Fixture Units (FU) 540 Treatment Plant Number of Sq Ft 140668 Durham Water District Tigard Permit Fixtures Description.: ` •!Quantit I Y 1 ' • Description Quantity Description . • 'Quantit Dishwasher - Commercial S 1 j I Drinking Fountain J I 8 I I Floor Drain - 3 inch 28 Sink - Bar 6 Sink - Bradley J J 8 I Sink - Service I 50 I Washer, Clothes l I Water Closet [ 26 I Urinal II 4 I Fee Description Amount Erosion Control Inspection Fee 1,816.00 • Erosion Control Plan Check' Fee 1,180.40 Sanitary SDC Fee (Connection) 84,375.00 Water Quality SDC 0.00 Water Qua ntity SDC -3- 14,652.92 Sub Total 102,024.32 TOTAL 102,024.32 I HEREBY CERTIFY THAT THE • : . E INFORMATION IS CORRE or CT. S IGNATURE: Y S� Date: Z («, (Qs TIGARD- TUALAT SCOOL DIST 235 c/o RIDER, ALBERTA L: • C ITY OF TIGARD SITE WORK PERMIT II 't DEVELOPMENT SERVICES PERMIT #: 3/10/2 4 -00029 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED : 3/10!2005 SITE ADDRESS: 14850 SW 132ND TERR PARCEL : 2S109AC 02100 SUBDIVISION: ALBERTA RIDER ELEM. SCHOOL ZONING : R - BLOCK: LOT: JURISDICTION : URB CLASS OF WORK: NEW PAVING ?: Y RESO. NO: TYPE OF USE: COM GRADING ?: Y VALUE: 1,000,000.0 EXCV VOLUME: 4,362 cy LANDSCAPING ?: Y FILL VOLUME: .29,000 cy SITE PREP ?: Y ENG FILL ?: Y STORM DRAINS ?: Y SOILS RPT READ ?: Y IMPERV SURFACE: 143,286 sf Remarks: Site work for new elementary school. Owner: FEES TIGARD - TUALATIN SCHOOL DISTRIC • Description Date Amount 6960 SW SANDBURG RD [UBUPLN] PhiCk -Va1u 11/5/2004 TIGARD, OR 97223 $2,652.52 [UFLS] FLS Pln Rv 11/5/2004 $1,632.32 [UBUILD] Prmt Fee -Val 3/10/2005 $4,080.80 Phone: 503 [UTAX] Valu 8% State Surcha) 3/10/2005 $326.46 >[WQUANT] Wtr Quant % 3/10/2005 $15,125.00 Contractor: Total $23,817.10 ROBINSON CONSTRUCTION 21360 NW AMBERWOOD DR - HILLSBORO, OR 97124 -9321 Phone: 503- 645 -8531 REQUIRED ITEMS AND REPORTS Reg #: LIC 63147 m .«� Engineered soils • This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adop =:.y - . -gon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 -00 -0100. You may obtain copies of these rules or direct questions to OUNC by calling (503) 246 -6699. . Is ed By: OA 4' Permittee Signature: ■ (of 05 Call (503) 639 -4175 by 7:00 P.M. for an inspection the net business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. uiuu��ri�r °IV ugtVfi�� ��,�\ March 4, 2005 .4.; CITY OF TIGARD EEA Architects, PC OREGON 1230 SW First Avenue, Suite 300 Portland, OR 97204 RE: ALBERTA RIDER ELEMENTARY REVIEW Project Information Site Permit: SIT2004 -00029 Construction Type: II - 1HR Tenant Name: Alberta Rider Elementary Occupancy Type: E- 1,A2.1, B, S -1 Address: 14850 SW 132nd Terrace Occupant Load: 2,366 Area: 67,849 Sq Ft Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The submitted plans are approved subject to the following. EROSION 1. Erosion control measures shall be in place prior to excavation or grading. FIRE 2. The private fire service main shall be at least 30 inches below grade. 3. The private fire service main shall be flushed thoroughly before connection to the system riser in order to remove foreign materials that might have entered the main during the course the installation. The flow rate shall not be less than the water demand rate of the system. 4. All piping shall be inspected prior to backfill. FIRE DEPARTMENT ACCESS 5. The driveway is considered a fire department access roadway. The driveway, to the point of the "Hammer Head" turnaround, shall be capable of supporting a 12,500 pound wheel point load and a gross vehicle weight of 50,000 pounds. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 ACCESSIBILITY 6. Accessible walkways and routes shall not exceed a running slope of 1 unit vertical in 20 units horizontal (5% slope). Cross slopes shall not exceed 1 unit vertical in 50 units horizontal (2% slope). 7. Accessible parking spaces and access aisles shall be located on a surface with a slope not to exceed 1 unit vertical in 50 units horizontal in all directions. 1104.4.3 OSSC Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC which may not include all of the requirements of the ADA. Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, , r. al Hemel, Senior Plans Examiner • • 1 Dec•16. 2064 3 18 PMba.TLy4e>32' EEA ARCHITECTS No.8356 P. 2E 0 "/e5 MEMORANDUM EEA ARCHITECTS P.C. ) q t ,5(.) ► 3 2-NV X12, 1230 SW FIRST AVENUE, SUITE 300 PORTLAND, OREGON 97204 -3236 S /770760 (/- Do0Z47 a 503.223.6963 / FAX 503.294.0827 1 . 0 • TO: Craig Markus December 15, 2004 Cornerstone Construction Management 5331 SW Macadm Avenue, Suite 377 Portland, Oregon 97239 cc: FROM: Greg Weller 0 b ® FAXED, 3 PAGES / FAX NO.: (503) 295 -1896 El MAILED 0 MESSENGERED SUBJECT: City review comment responses for 12/7/04 memo . FIRE REVIEW; 3_ TVF&R Fire Flow & Hydrant Worksheet was submitted by Cornerstone & Accepted by City 12/15/04. 4. On Civil Drawing, see C2.4 & C2.5 sheets and specifications for underground piping and valve equipment cut sheets. System is also a deferred submittal. ACCESSIBILITY: 5. See sheets C2.1&C2.2 for slopes, and will be further clarified with Westlake's new City submittal via Cornerstone. Accessible route was told to not be required of this project since we have refuge areas, however 6% is provided along the main sidewalk axis running north -south from the main entrance of the building to J street. 6. On Architectural drawing sheet A2.2, detectable warnings are provided at vehicular crossings per 1/112.1 and 17/A2.2. � We have revised the site layout to delete the 8 stalls along the parent drop -off curb line per attached clarifica 010 whi adds to pole signs per ke yno t e 43 8. It is correct to state the current design has the access aisle on the wrong side of the first ADA parking stall_ Due to line Item #7 above, we have revised the ADA parking to simply flip the Western most ADA stall with it's access aisle per attached clarification 007 Page 1 of 1 1 Dec.16. 20045 3 EEA ARCHITECTS No.8356 P. 3E 2/ Ark = 1 'XV @ D- I }- 1......... r 0 0 II „„.,,dre-JhaIIIIIIIIIN,P .. p r .... • AML AM th i I VP... addlillill (10 LAND'CAFt 8 A 16 I I TP r . • . = ll • ' .9 . _ ... Tyl ic, p , yap ... 4CTILE W4 - 4 IN ON ' :. 5214t,IRETE - AID - li 101-0" IMO Aumft ga l i 1 a , la i (-> niiiiis iwniriorni.,• ;woo (-'..\\.„ _ Ii i i...,,s,„,.....0"...-...1.0..e .,,, ,„.„ ,,,,,I.„,,,,...,,0,,,,,,—..,__. : ...„ ...... • ... .,,,„, „,,.........„._,...0,._._...... . 013.5.•ttioo, .t..,-.02.1 .., . 01,.......... v . ....._____,...... vm pr- 10, „:” ......-- 0 , -0„ 10.2,adil --- 1" e ...,........:„:„..............„...: ppp" , ' ' . . 1--PIAN& de TO T 'AL rEJE - Aft :;' Y - C r agh •■• Imr aim gra iv .1 m .,o . ■ elel■ IltSr .......,.........„................/' AI ( N 1 3N , 1 : .. IA 9NV 1112 - 1= .....________ is - 001019w■0011111111 . iii* ‘010 i.\ 0_ AI, , 0% , iiall,_,..16100.470010 , OnT0001011 NOVO IN 0 • Ii0 10011 .00 '10 * 4 it ; zip 111 ' . ' , 000 0°11 10 014 . ■ " ogille *OW 0 VYL@IgrOl Potorgl0 I ... 00°111 ' 0 0.1./ %0 00111 600 01611 , 41100,001001_.00010_, 00 •••••••• ••••• 0 I .4 ora_Mirims 0 okonsesso00.001- 010 ........---4 .... MEM * •? ■ Slilla EL0 111111111 e.■ -el . crr 1011116 . 4CCES515LE FA'KING , • . A, NI I i . . • I , cl 10.22..0‘ ACCESSIBLE PARK'( ALBERTA RIDER ELEm a7C—DAttwr7sr, 42cle O 007 00 CHCoOZO BO OW OCW:(.1r SW 133RD & BULL MOUNTAIN ROAD TIGARb, OREGON 97224 .2 F$ COOLcon_kaotota A . 11 .111.1.4 MICK ArzeoclIATtelmiviirtEole P.G. 1230 SW Prat Ave., •300 PorOand. orsnan 17204 - P. f5O,91 223-OOOst FA, IKOA1 /n.2.4.1F127 1 Dec•16. 2004 3 :18 PM5032940827 EEA ARCHITECTS No•8356 P. 4E 03/85 • ' RIGi<C - (8) STATION UNIT. SEE DETAIL Vie \ - / I P RFOvIDE BT ARD ODOT TOP' SIGN WI TN GALVANIzEo f loor AND caNcRETE / // FOOTIN[; ® 8" WIDE BAR W114 3 G'J' 6OLID CENTt.LINE MARk.ER A 1BTop' PAvEmEU - MAR4CING - / 1 SEE DETAIL ..A.. Q • D0:1 6TIC WATER BACiO-LCW DFYICE WITH VA LT - RI FBR To o1V11_ =s: h ill r/IIMI I <D WATER QUALITY ALITY SWALIB - ER TO CIVIL PR4WlNp$ FOI2 CCNSTT .lCTrot4 AND F. LAe1DBCApw DRAINING FOR FLAWING. / riot USED. / P. S' -0• HIGH cortTIAWOuO ct AfN -LI1 FTNCit WIN QI N SLAT& FOI -LCW TOP OF SLOPE. . LPd.ESS NOTED OTHERWISE. V-6' 1NeIDE PROpERTr LINE WHERE L TED PARRALLEL iffil ® AND ADJACENT TO PROPERTY LIN1 . SEE DETAIL AT WALtGUA7S Not USED. A. 13'-®" Or* - UNLESS NOTED OTHERWISE L Q X 44 -J , �7 HATCH ADJAC -TNT MICE f1E16NT. DOUL� GiJiR! - �U HC GATE ® PRIY$ABLE POROUS FaAVERs p::;;;;;;;;;1 . SWINGING GATE WTf-1 LoOGN3 HAr3P - MATCbi WIDTW OF Wci. 4 A7 WHERE occJR3 OR .. ill +I WIDE 11INf f, I^IEICINT TO 1'tATG EKT N ADJAC FENCE FIEIC,LIT PER I . a TA al I1 -- 4' Dot•TESTIC WATER METER VAULT • REFER TO CIVIL ® S'•.m ° CONTINUOUS DETAIN - FR -CING - PLACE 36. oc,tra1DE PLAY AREA AT 601.111-1 . = kg I _ 0 1 a10E. CiENNTER ON CU CURB AT fLt&T BIDE - OMAR C TIGN. s' ® NOT USED r • Not US):D. . 1 J 1r i ® 4' -0■ 1- CONTINUO-IS CI -FAIN LINK F We N:a, LocATE S° FROM SIDEWALK CR CCt`ICRE -TE Ell? 36. I — li CURB ON BIM DEPICTED (OR Om OUTSIDE TENANCY LpNEB 0 CATo.1 BASIN - JAR TO CIVIL I� 4 O NSA DIQ.41N - IRET-tR TO or ' • , .: .. a • a "'CAL ENT CF (') - PAINT ENTIRELY: WERE _ - OCCU • ADJ S ENT TO -, RS OR EDGE OP PAVING, PRov1DE I2. Op aMAR SPACE. seE DETAI " . 4 FQ$T SIGN =1AGE TO READ. °fD MUILFTE PAJ�CIhU LiI'f1T Fda7f I B At"! TO da00p11 - 1111211. BEE DETAF A1• ` ExTERIOR B-^ , 14 - PL{tGE AS CLOte TO THE I: WILDING EXTNRk2R AS p osel LE - - -rE - DEST • FOR Tt L E.. IFifF1NT RJFY -._ .. I , s , a um r IK Hil . � �: ,,,. ; ,r 1- _ ,�z _,. _ r,v •••, - ..- -ANY G„ PAD mo NTEp TRA 1ERB AND METER BASES - VERIFY REG/U 11E4n WITH UItLrTY Z I ® 60 04=0.1 UNIT PAV�23 cE TERLD ON PLANTER3 EILOCKGUT IN cacRETE SIDEWALK. ER READABLE M NORTI1, 4 2ENERA1TrR Oven a" CON•RV BLAB AT FOctpRINT - SEE ELECTRICAL FOR CLEARANCE6 PROM TRANSFORMER - VERIFr REouIREMENTe wi 4 UTILITY O1PA.4 ® IfRRkGATION BOOSTER - sEE LANDSC.A} _ I j:: 4 Ala lltdii PLACPOLE - DeE DETAIL® I 4 6= BTRBJCTURAL FOR REINFO �CEt r AT WALL/SIaFLUALIC ' 8 M - 41 A6 Rr WALL - SEE DETAIL® > , • EXTENT OE ubR!' TH}8 COMA= /GT E?(TENGS TTO GP RkSuT OP MAY ON ILgbT PRPFERTT LINE ONLY. TlNIO CONTRACT DOES NOT INCLUDE dhow WITHIN RIGA' OF WAY. 11111 ' / 7 J1 1110 .1. mil r /A2 -o DATE 10- 22-•04 1 SITE PLAN COIF No., ALBERTA No., 0208.00 REVISED DRAM E ' ' ' 010 olIcr>D ow SW 133RD & BULL M ROAD TIGARD, ORE 07224 Yr = � �� FILE 02fla_CO10_A100.d.p LII EL_L% Et341CK A88CCIATEB ITEM P,C_ t280 6W Flrat Ava. /93 Portland, Orero i 87204 - PI% CS 031 1:23- 0'29 2 Fax 1603) 221 -0527 ! `tg5O S ca/ 13z•r T 811/1i �� iu ipggll ill May 20, 2005 CITY OF TIGARD OREGON Jer Pratton, ED D Tigard - Tualatin School District 6960 S.W. Sandburg Street Tigard OR 97223 Dear Jer: This letter is regarding Condition No. 13 of the Alberta Rider Elementary School land use approval; more specifically, the condition which requires elimination of the east Rider driveway off of Bull Mountain Road. A meeting was held several weeks ago and a discussion ensued regarding this condition; no conclusion was reached at that time. I have learned, however, that if the School District is considering an appeal for the driveway to remain, it would be a very long and complicated process. First and foremost, the appeal period has long expired. Because the driveway was decided as part of the Conditional Use application, the condition is part of a Type III Hearings Officer decision. We cannot modify that decision. In order to modify the Hearings Officer decision, a complete hearing process, including pre -app meeting, neighborhood meeting, application and hearing review by the Hearings Officer would be required. The School District used this driveway closing in argument for approval of their emergency access which is approximately 80 feet away. Should the emergency access go away once the school is completed, there are separate issues regarding the Rider driveway. It would fall under an adjustment to 18.705 H. Access Management Standards, which requires a 200 -foot separation which may not be achievable in this case. There are clear review criteria for this adjustment, including that there are no other alternative access points and it is not possible to share access. As a result, it would be difficult, if not impossible, to meet the approval criteria. Also consideration would have to be the street access to the Alpine View Subdivision as well as other driveways across the street. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Jer Pratton, ED D Alberta Rider Driveway Condition Page 2 May 20, 2005 To seek an adjustment would be a Major Modification to the Conditional Use Permit approved by the Hearings Officer for CUP 2003 - 00012. This would be a very long process without guarantee of approval. Should you have questions or concerns, please do not hesitate to contact me. Sincerely, James N.P. Hendryx, Community Development Director /sr cc: Stephen Poage, Tigard - Tualatin School District Craig Prosser, Interim City Manager Dick Brewersdorff, Planning Manager Kim McMillan, Private Development Manager December 7, 2004 u�d��i�NUantiQ���'� • • • CITY OF TIGARD EEA Architects, PC OREGON 1230 SW First Avenue, Suite 300 Portland, OR 97204 RE: ALBERTA RIDER. ELEMENTARY • Project Information • Site Permit: SIT2004 -00029 Construction Type:II - 1HR Tenant Name: Alberta Rider Elementary Occupancy Type: E- 1,A2.1, B, S -1 Address: 14850 SW 132nd Terrace Occupant Load: NA Area: 67,500 Sq Ft Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -. 01) 1999 edition. The following information is required prior to the issuance of a Site Permit: EXCAVATION 1. Complete the enclosed permit application clarifying the Excavation, Grading and Fill volumes. 2. Clarify the new impervious area. Impervious is defined as building roof areas, sidewalks and paving. The number should be what is new impervious as related to what was existing. FIRE REVIEW 3. Complete the enclosed "TVF &R FIRE FLOW and HYDRANT WORKSHEET ". The allowable area permitted and the number of hydrants required will be based on the worksheet. 4. Underground Fire Fighting Water Supply. Provide piping sizes and materials, valve equipment cut sheets. All valves shall be listed for use in a fire service application. ACCESSIBILITY 5. Clarify the accessible route to the public way as required by section 1103.1 • OSSC. Please indicate slope on the plans. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 6. Clarify the detectable warnings that will be provided when the accessible route crosses a vehicular way. See section 1103.2.3.2 OSSC 7. Clarify the total accessible parking as shown on plan page C2.3 = 79 spaces, required minimum number of accessible spaces should be 4. 8. Clarify that Accessible parking access aisles are located on the passenger side of the parking space except that two adjacent accessible parking spaces may share a common access aisle. ORS 447.233, 1104.1 Please provide an item by item response. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectful Val He , Senior Plans Examiner • • ALBERTA RIDER ELEMENTARY SCHOOL CONDITIONS OF APPROVAL CUP 2003 -00012 THE FOLLOWING PLANNING CONDITIONS ARE REQUIRED TO BE MET PRIOR TO ISSUANCE OF A SITE PERMIT: 1. The applicant shall place the following note on all construction documents: "The City of Tigard Noise Ordinance prohibits construction activity in excess of 40 decibels between 9:00 p.m. and 7:00 a.m. Monday through Friday, and between 9:00 p.m. and 8:00 a.m. on Saturday and Sunday. 2. The applicant shall submit a final tree removal and protection plan that identifies the trees to be removed and the trees to be protected. Mitigation will then be based on the final tabulation of trees removed to those retained, per Section 18.790.030. 3. The applicant shall provide the City Arborist with a construction sequence including installation and removal of tree protection devices, clearing, grading and paving. 4. The applicant shall notify the City Arborist when tree protection measures are in place so that he may verify that the measures will function properly prior to construction. 5. The applicant shall submit permit drawings that clearly indicate the visual clearance areas for all intersections and access points along with recommendations by the applicant's engineer to achieve clear vision and adequate site distance. THE FOLLOWING ENGINEERING CONDITIONS ARE REQUIRED TO BE MET PRIOR TO ISSUANCE OF A SITE PERMIT: MET 6. A Public Facility Improvement (PFI) permit is required for this project to cover street improvements and any other work in the public right -of- way. Eight (8) sets of detailed public improvement plans shall be submitted for review to the Engineering Department. NOTE: These plans are in addition to any drawings required by the Building Division and should only include sheets relevant to the public improvements. Public Facility Improvement (PFI) permit plans shall conform to City of Tigard Public Improvement Design Standards, which are available at City Hall and at the city's webpage www.ci.tigard.or.us. MET 7. The PFI permit plan submittal shall include the exact legal name, address and telephone number of the individual or corporate entity who will be designated as the "Permittee" and who will provide the financial assurance for the public improvements. For example, specify if the entity is a Corporation, LLC, limited partnership, etc. Also specify the state within which the entity is incorporated and provide the name of the corporate contact person. Failure to provide accurate information to the Engineering Department will delay processing of project documents. 8. Additional right -of -way shall be dedicated to the public along the frontage of Bull Mountain Road to increase the right -of -way to 37 feet from the centerline. The description shall be tied to the existing right -of -way centerline. The dedication document shall be on city forms. Instructions are available from the Engineering Department. MET 9. The applicant shall submit construction plans to the Engineering Department as part of the Public Facility Improvement permit, which indicate that they will construct a half - street improvement along the frontage of Bull Mountain Road. The improvements adjacent to this site shall include A. City standard pavement section for a Collector street from curb to centerline equal to 23 feet; B. Pavement tapers needed to tie the new improvement back into the existing edge of pavement shall be built beyond the site frontage; C. Concrete curb, or curb and gutter as needed; D. Storm drainage, including any off -site storm drainage necessary to convey surface and /or subsurface runoff; E. Six-foot concrete sidewalk with a planter strip; F. Street trees in the planter strip spaced per TDC requirements. Species selection shall be as recommended by the City Arborist. Such trees shall be installed prior to final building inspection. G. Street striping; H. Streetlight layout by applicant's engineer, to be approved by City Engineer; I. Underground utilities; J. Street signs, if applicable; K. Driveway apron, if applicable; L. Adjustments in vertical and /or horizontal alignment to construct SW Bull Mountain Road in a safe manner, as approved by the Engineering Department. MET 10. The applicant's plans shall show installation of bicycle striping, markers, legends and mini - arrows along the Bull Mountain Road frontage. 1i. Prior to commencing onsite improvements, the applicant's design and construction plans shall include the left -turn lane with loo -foot of storage for west- bound traffic on Bull Mountain Road at the intersection of 1 33rd Avenue, if the design has not already been completed by others. (Note: Need assurances by Venture Properties). • r p +12. Right -of -way shall be dedicated to the public for at least a cul -de -sac termination of the "F" Street stub on the site as approved by the city. The applicant's Public Facility Improvement permit construction drawings shall indicate that improvements, including at least traffic control devices, concrete sidewalks, driveways aprons, curbs, asphaltic concrete pavement, street trees, streetlights and underground utilities, shall be installed to complete a permanent termination of ,,F Street as a cul -de -sac on the site. Improvements shall be designed and constructed to local street standards. This condition shall not preclude and expressly authorizes dedication and improvement of an extension of F Street from the south edge of' the site along the west edge of the site to the east -west public access road to dimensions, and standards approved by the city. MET 13. The applicant's plan shall show the east Rider driveway eliminated. MET 14. The applicant's plans shall show the proposed access onto Bull Mountain Road as an emergency only access. That access shall be gated or otherwise improved to prevent general public motor vehicle access, but shall be accessible to emergency services providers, pedestrians and bicyclists. The access may be used for general public motor vehicle access only during an emergency or when otherwise approved for that purpose by the Planning Manager. Case Note: No emergency access proposed. 15. Deleted 16. A profile of Bull Mountain Road shall be required, extending 30o feet either side of the subject site showing the existing grade and proposed future grade. 17. Sanitary sewer and storm drainage details shall be provided as part of the Public Facility Improvement (PFI) permit plans. Calculations and a topographic map of the storm drainage basin and sanitary sewer service area shall be provided as a supplement to the Public Facility Improvement permit plans. Calculations shall be based on full development of the serviceable area. The location and capacity of existing, proposed, and future lines shall be addressed. 19. The applicant shall provide a public sanitary sewer main from the intersection of 133rd Avenue and the new east -west street to the stub shown in F Street on the approved Summit Ridge subdivision plans. Note: Assurance required by Venture. 20. The applicant shall extend the public storm sewer in the east -west street to the intersection with 133rd Avenue. Note: Assurance required by Venture. 21. Prior to construction, the applicant's design engineer shall submit documentation of Clean Water Services (CWS) approval of the proposed storm sewer system for review by the city (Kim McMillan). 22. Any extension of public water lines shall be shown on the proposed Public Facility Improvement (PFI) permit construction drawings and shall be reviewed and approved by the City's Water Department, as part of the Engineering Department plan review. NOTE: An estimated 12% of the water system costs must be on deposit with the Water Department prior to approval of the PFI permit plans from the Engineering Department and construction of public water lines. 23. The applicant's plans shall be revised to show a new, public 12 -inch line connecting to the io -inch line in Bull Mountain Road. This 12 -inch line will need to be public in order to serve properties beyond the borders of this site. The 12 -inch line needs to be connected to the waterline shown in F Street on the approved Summit Ridge plans. A public waterline also needs to be extended the full length of the new east -west street, from the site to 133rd Avenue. A minimum 15 -foot public easement will be required where the waterline is located outside of the public right -of -way. 24. The applicant shall provide an on -site water quality facility as required by Clean Water Services Design and Construction Standards (adopted by Resolution and Order No. 00 -7). Final plans and calculations shall be submitted to the Engineering Department (Kim McMillan) for review and approval prior to issuance of the site permit. In addition, a proposed maintenance plan shall be submitted along with the plans and calculations for review and approval. The applicant shall also provide the City with approval from CWS for the water quality facility. 25. An erosion control plan shall be provided as part of the Public Facility Improvement (PFI) permit drawings. The plan shall conform to the "Erosion Prevention and Sediment Control Design and Planning Manual, February 2003 edition ". 28. The applicant shall obtain a 1200 -C General Permit issued by the City of Tigard pursuant to ORS 468.740 and the Federal Clean Water Act. 29. The applicant shall submit preliminary sight distance certification for all driveways and intersections related to this development. Included with the preliminary certification shall be a detailed list of improvements required to produce adequate sight distance. 37. Prior to submittal of permits, the applicant shall pay an addressing fee according to the rate at the time of payment. Contact Shirley Treat, Engineering. THE FOLLOWING PLANNING CONDITIONS ARE REQUIRED TO BE MET PRIOR TO ISSUANCE OF A BUILDING PERMIT: 32. Prior to issuance of building permits, the applicant shall submit a final lighting plan that indicates the lighting levels for the pathways on site. Ensure that all lighting on site will not cause glare (measured as 1 foot candle at the property line) to adjacent properties. This plan shall also address glare onto abutting properties from outdoor field lighting, if applicable. Lights shall be generally oriented towards the school building and not toward the abutting properties. The lighting plan shall include photometric data to demonstrate compliance with the requirement. 33. Screening shall be provided on all sides of the project that abut residential property. This requirement may be waived for those properties where the applicant has secured written authorization from these abutting property owners to forgo this screening. 34. . Prior to issuance of building permits, the applicant shall submit a revised landscaping plan that shows: A. Street trees along both sides of West Access Road and one side of SW Bull Mountain Road, and the F Street cul -de -sac (or the eastside of an extended F Street). Species selection shall be as recommended by the City Forester and planted at the required spacing. Such trees shall be installed prior to final building inspection. B. Additional screening (vegetation or a siglfobscuring fence) along the western edge of the bus loading area and the eastern edge of the parking area. C. Dimensions of the landscape islands to demonstrate that tree planting areas have a minimum three feet of width. 35. The applicant shall satisfy the requirements of Section I of Washington County's Land Use and Transportation Department's letters dated June 3 and May 25, 2004, and provide written confirmation from the county that their requirements have been satisfied. 36. The applicant shall revise the site plan to indicate how Section 18.755.050 compliance will be attained. THE FOLLOWING ENGINEERING CONDITIONS ARE REQUIRED TO BE MET PRIOR TO ISSUANCE OF A BUILDING PERMIT: 38. During issuance of the building permits, the applicant shall pay the standard water quantity fee (fee amounts will be the latest approved by CWS). • THE FOLLOWING PLANNING CONDITIONS ARE REQUIRED TO BE MET DURING CONSTRUCTION OF THE PROJECT OR PRIOR TO FINAL INSPECTION /OCCUPANCY: 30. Deleted. Refer to condition #48. 31. Lights and an amplified sound system for the playfield shall not be provided. 39. Applicant shall obtain annexation approval. 4o. The applicant shall ensure that the recommendations of the project arborist regarding tree care have been implemented. 41. The applicant shall satisfy the requirements of Section II of Washington County's Land Use and Transportation Department's letters dated June 3 and May 24, 2004. 47. Prior to placement of any signs on site, the applicant shall apply for a sign permit and supply staff with the appropriate plans to verify compliance with TDC Chapter 18.780. 48. At any time after the school begins operations, if the planning manager finds that the noise level at the south property line of the school exceeds an Leq of 60 dBA, he or she may require the applicant to install noise attenuation measures to reduce noise levels to 60 dBA or may schedule of public hearing before the hearings officer to consider whether such requirements should be imposed. THE FOLLOWING ENGINEERING CONDITIONS ARE REQUIRED TO BE MET DURING CONSTRUCTION OF THE PROJECT OR PRIOR TO FINAL INSPECTION /OCCUPANCY: 18. During construction, the applicant shall provide connection of proposed buildings to the public sanitary sewage system. A connection permit is required to connect to the existing public sanitary sewer system. (Note: Need assurances by Venture Properties). 26. A final grading plan shall be submitted showing the existing and proposed contours. The plan shall detail the provisions for surface drainage of all impervious areas, and show that they will be graded to insure that surface drainage is directed to the street or a public storm drainage system approved by the Engineering Department. For situations where the back portions of the lot drains away from a street and toward • adjacent lots, appropriate private storm drainage lines shall be provided to sufficiently contain and convey runoff. 27. The applicant shall incorporate the recommendations from the submitted geotechnical report by URS Corporation, dated July 2003, into the final grading plan. The geotechnical engineer shall be employed by the applicant throughout the entire .construction period to ensure that all grading, including cuts and fills, are constructed in accordance with the approved plan and Appendix Chapter 33 of the Uniform Building Code. 42. The applicant shall complete the required public improvements, obtain conditional acceptance from the City, and provide a one -year maintenance assurance for said improvements. 43. The applicant shall either place the existing overhead utility lines along SW Bull Mountain Road underground as a part of this project, or they shall pay the fee in -lieu of undergrounding. The fee shall be calculated by the frontage of the site that is parallel to the utility lines and will be $35 per lineal foot. If the fee option is chosen, the amount will be $20,667.50 and it shall be paid prior to final building inspection. 44. The ensure compliance with Clean Water Services design and construction standards, the applicant shall employ the design engineer responsible for the design and specifications of the private water quality facility to perform construction and visual observation of the water quality facility for compliance with the design and specifications. These inspections shall be made at significant stages, and at completion of the construction. Prior to final building inspection, the design engineer shall provide the City of Tigard Inspection Supervisor (Hap Watkins, Building Division) with written confirmation that the water quality facility is in compliance with the design and specifications. 45. The applicant's geotechnical engineer shall submit a final report to the Building Division that indicates all grading work on this site was inspected by said geotechnical engineer, and that it was completed in accordance with Appendix Chapter 33 of the Uniform Building Code. 46. Final sight distance certification for all intersections and driveways associated with this development shall be provided by the applicant's engineer. Planning Staff Contact: Morgan Tracy Engineering Staff Contact: Kim McMillan Permits Coordinator: Sue Ross December 7, 2004 EEA Architects, PC 1230 SW First Avenue, Suite 300 Portland, OR 97204 RE: B.A.P.S. TEMPLE Project Information Site Permit: SIT2004 -00029 Construction Type:II - 1HR Tenant Name: Alberta Rider Elementary Occupancy Type: E- 1,A2.1, B, S -1 Address: 14850 SW 132nd Terrace Occupant Load: NA Area: 67,500 Sq Ft Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99- 01) 1999 edition. The following information is required prior to the issuance of a Site Permit: EXCAVATION Complete the enclosed permit application clarifying the Excavation, Grading and Fill volumes. Clarify the new impervious area. Impervious is defined as building roof areas, sidewalks and paving. The number should be what is new impervious as related to what was existing. FIRE REVIEW Complete the enclosed "TVF &R FIRE FLOW and HYDRANT WORKSHEET ". The allowable area permitted and the number of hydrants required will be based on the worksheet. Underground Fire Fighting Water Supply. Provide supply pipe burial depth, piping sizes and materials, valve equipment cut sheets, vault details, equipment in vaults, details for hydrants and Fire Department Connection (FDC) location that are necessary for the installation of the fire service. All valves shall be listed for use in a fire service application. ACCESSIBILITY Clarify the accessible route to the public way as required by section 1103.1 OSSC. The accessible parking shown on sheet does not provide an accessible route from the access aisle to the proposed structure. 1103.1 OSSC Clarify the detectable warnings that will be provided when the accessible route crosses a vehicular way. See section 1103.2.3.2 OSSC Accessible walkways and routes shall not exceed a running slope of 1 unit vertical in 20 units horizontal (5% slope). Cross slopes shall not exceed 1 unit vertical in 50 units horizontal (2% slope). 1103.2.4.3 OSSC Accessible parking sign shown in detail is required to be 84 inches to the bottom of the sign. Revise the detail. • Total accessible parking as shown on plan page C2.3 = 79 spaces, required minimum number of accessible spaces = 4. Accessible parking access aisles as shown on plan page C2.3 need to be located on the passenger side of the parking space except that two adjacent accessible parking spaces may share a common access aisle. ORS 447.233, 1104.1 Clarify the excavation volumes and impervious areas on the second sheet of the permit application. Please provide an item by item response. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. - Respectfully, Val Henzel, Senior Plans Examiner • ,„„ ,. . March 4, 2005 - +` CITY OF TIGD EEA Architects, PC OREGON 1230 SW First Avenue, Suite 300 Portland, OR 97204 RE: ALBERTA RIDER ELEMENTARY REVIEW Project Information Site Permit: SIT2004 -00029 Construction Type: II - 1HR Tenant Name: Alberta Rider Elementary Occupancy Type: E- 1,A2.1, B, S -1 Address: 14850 SW 132nd Terrace Occupant Load: 2,366 Area: 67,849 Sq Ft Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The submitted plans are approved subject to the following. EROSION 1. Erosion control measures shall be in place prior to excavation or grading. FIRE 2. The private fire service main shall be at least 30 inches below grade. 3. The private fire service main shall be flushed thoroughly before connection to the system riser in order to remove foreign materials that might have entered the main during the course the installation. The flow rate shall not be less than the water demand rate of the system. 4. All piping shall be inspected prior to backfill. FIRE DEPARTMENT ACCESS 5. The driveway is considered a fire department access roadway. The driveway, to the point of the "Hammer Head" turnaround, shall be capable of supporting a 12,500 pound wheel point load and a gross vehicle weight of 50,000 pounds. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 ACCESSIBILITY 6. Accessible walkways and routes shall not exceed a running slope of 1 unit vertical in 20 units horizontal (5% slope). Cross slopes shall not exceed 1 unit vertical in 50 units horizontal (2% slope). 7. Accessible parking spaces and access aisles shall be located on a surface with a slope not to exceed 1 unit vertical in 50 units horizontal in all directions. 1104.4.3 OSSC Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC which may not include all of the requirements of the ADA Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, al Henzel, Senior Plans Examiner 1 ITS 0oa9 I L / gSo 5 w 132'' T February 1, 2005 i in To: Gus Duenas, City Engineer ee r City of Tigard Fr: Stephen D. Poage, Director Capital Projects Tigard Tualatin School District Sub: Bull Mountain Road Street 1 ----- - -- Tigard Tualatin School District and West Hills Development have agreed to bid the Bull Mountain Road Street Improvements as one document and hire one contractor for the work. This work will be permitted under a separate Public Facilities Improvement permit (PFI) which is not attached to the Alberta Rider Elementary School or Arbor Summit Subdivision. AS AO Z St• • D. 'oage, I 'tor apita mprove '-nts Z Tigard- Tualatin School District °, LLLL O J OUZCn _ w — "t' —1:1 _ — — -- LL � a cn n Z° n f (P . • INDIVIDUAL ACKNOWLEDGMENT eAt 01 —a v" �> S � S! .•. •�S4 t S 5 .•! S!� .• .�S .�aS! .'� � 5!a t t!TS .•!:�S N,. t . 5 .!�i a te, State /Commonwealth of O5 N ~ }ss. County of Ct-SWk(N.C'1 ('— S� On this the ' day of k , before Day Month Year me, , the undersigned Notary Name of Notary Public Public, personally appeared . • • 411k•_ Name(s) of Signer(s) 4 rsonally known to me — OR — ❑ proved to me on the basis of satisfactory evidence OFFICIAL SEAL to be the person(s) whose name(s) is /are 26.1. ,:A'° SUE ROSS subscribed to the within instrument, and "� NOTARY PUBLIC - OREGON acknowledged to me that he /she /they COMMISSION N0.375152 MY COMMISSION EXPIRES DEC. 1, 2007 executed the same for the purposes therein stated. WITNESS my hand and official seal. A . _J// 4111 Signature o Notary Public Other Required Information (Printed Name of Notary, Residence, etc.)