Loading...
Report 3(1P2.4 - 00/ 95 7921 so/ V1/4sw V &TON SQUIf RE RD h erl(n T T 7499 SW Tech Center Dr. Ste. 145 T i OR. 97223 nxcxLTe Ph: 503-443-3799 Fax:503- 620 -2748 503.443.3799 REPORT OF CONCRETE CYLINDER TEST Project Number: 10- 3075 -000 Report Number: 16536 Project: H & M WASHINGTON SQUARE Client: PLEGER -HENRY ARCHETECTURE Address: 15640 N 7TH ST, SUITE B9 PHOENIX, AX 85022 Attn: FIELD TEST CONDITIONS AND RESULTS (ASTM C31 Date Placed: 9/20/2010 Time Sampled: 12:30PM Location of Sample: 2ND FLOOR METAL SLAB, INTERIOR OF BUILDING, WEST SIDE OF SPACE. Supplier: ROSS ISLAND Truck Number: 210 Ticket Number: 476272 Mix Number: 3531C Design Strength: 3 5 0 0 psi Time Batched: 11 : 51AM Time Placed: Batch Size: 11 yds. Slump: 7. 0 in. (ASTM C 143) Air Content: 1.5 % (ASTM C 173) Concrete Temp: 70 OF Ambient Temp: 54 °F Water Added: 0 gal . Technician: N FRAZIER LABORATORY TEST RESULTS . (ASTM . C 39) Test Percent of Type of Specimen Date Age Load Diameter Area Strength Design Fracture A 9/27/2010 7 41030 4.00 12.57 3270 93% Cn B 10/18/2010 28 62900 4.00 12.57 5010 143% Cc C 10/18/2010 28 66510 4.00 12.57 5290 151a Cn D =H 0 4.00 12.57 Remarks: TYPES O / FRACTURE c i L g U I Type 1 Type 2 P Ty3 Copies to: i Type 4 Typ5 Type 6 Reported by: J I e ANS ACCREDITED 7409 SW Tech Center Dr. Ste. 145 .4004 Tigard. OR. 97223 d=1,mwm Ph: 503-443-3799 Fax:503-620-2745 503.443.3799 REPORT OF CONCRETE CYLINDER TEST Project Number: 10-3075-000 Report Number: 16537 Project: H & M WASHINGTON SQUARE Client: PLEGER- HENRY ARCHETECTURE Address: 15640 N 7TH ST, SUITE B9 PHOENIX, AX 85022 Attn: FIELD TEST CONDITIONS AND RESULTS (ASTM C 31) Date Placed: 9/2 0/2 0 1 0 Time Sampled: 2: 55AM Location of Sample: 2ND FLOOR METAL SLAB, INTERIOR OF BUILDING, WEST SIDE OF SPACE. Supplier: ROSS ISLAND Truck Number: 76 Ticket Number: 47 62 B1 Mix Number: 3 53 1C Design Strength: 3500 ps Time Batched: 1: 4 OAM Time Placed: Batch Size: 9 yds . Slump: 6 . 75 in, (ASTM C 143) Air Content: 1. 75 % (ASTM C 173) Concrete Temp: 70 .F Ambient Temp: 54 °F Water Added: o gal . Technician: N FRAZIER LABORATORY TEST RESULTS (ASTM C 39) Test Percent of Type of Specimen Date Age Load Diameter Area Strength Design Fracture A 9/27/2010 7 40870 4.00 12.57 3250 93% Cn 3 10/18/2010 28 63020 4.00 12.57 5020 143% Cn C 10/18/2010 28 60490 4.00 12.57 4810 137% Cn D=H 0 4.00 12.57 Remarks: TYPES OF FRACTURE Ty", Type 2 Type 3 Copies to: E Ej TYP64 Type 5 Type 6 Reported by: erfe Ir."5 ACCREDITED