Loading...
Correspondence • - ee) CITY OF TIGA RD • OREGON March 3, 1988 Paul J. Vogt PO Box 25549 Portland, OR 97225 -0549 RE: WCTM 1S1 36CA TL 700 Thank you for your concern on address assignment on the above listed property. After field checking the home, we agree that a better address assignment should be 11100 SW 78th Avenue, Tigard, Oregon 97223, as you suggested. Effective immediately, the address of 11128 SW 78th our office initially assigned is invalid and 11100 SW 78th Avenue is effective. We apologize for any inconvenience this may have caused you or your builder, Herb Morissette. We have notified the postal service, utilities, city and county agencies of this and have amended our records. If you have any questions, please give our office a call at 639 -4171. Sincerely, Zavra- Laura Freeman Engineering Technician /Cartographer cs/3520D (3e cc: 4e Building rb Morissette i g ity of Tigard Building Department 13125 SW Hall Blvd., P.O. Box 23397, Tigard, Oregon 97223 (503) 639 -4171 / / //// 7,4;iiilik CITY OF TIQA RD ORE GON January 27, 1989 Mr. Paul Voght 11100 SW 78th Ave. Tigard, OR 97223 Re: 1S1 36CA/700, Permit #870303 Dear Mr. Voght, As discussed on the morning of January 27, 1989, the floor beam in question is not over -span. The beam is a 4" x 8" DF #2 which will support the required 40 lbs. DL and 10 lbs. LL up to a span of 11.53 ft., as evidenced by the calculations given you. The existing span is 10 ft. -0 in. +/ -. As this is within loading limits for this use, I feel the requirements of the Uniform Building Code and the State of Oregon Building Code have been met. If I may be of further assistance, please contact me at 639 -4171. Sincerely, George Steele Building Inspector jlh cc: Herb Morissette Builders, Inc. 13125 SW Hall Blvd., P.O. Box 23397, Tigard, Oregon 97223 (503) 639 -4171 TOE: Herb Morissette Builders, Inc. 10400 SW Allen Blvd. RECEIVED Beaverton, OR 97005 DEC 1 5 1988 FROM: Paul J. & Patricia R. Vogt, Home Owner (639 -5554) 1 T01 -'S3W ..7_a h�--A e l Community Qom lopment Tigard, OR 97223 -2716 Re: YOUR FIRM'S RESPONSE TO Our Request for Construction and Warranty Corrections /Repair by your LETTER OF December 1, 1988. (Copy Enclosed) We do not agree with your action /conclusion on correction of the construction and warranty items! Since we have received your response, we have had an independent certified partial structural inspection conducted. A copy of this Inspection Report (Dated December 8, 1988) is ATTACHED. (The cost of this inspection will be reimbursed to us by either you, the Builder, the Cri:�y of T gard3• & /or FHA!) . Multiple G;i -ty -of�..:T.iga•rd & FHA construction inspections failed to report the FIRE /LIFE SAFETY and STRUCTURAL UB code violations and a certificate of occupancy was issued. The Report shows that the b ^i`ld nag- T-i-n.spe;pt -ior-► missed structural defects and that the home construction DOES NOT fully meet UBC building code: improper fire wall construction- Fire /Life Safety requirements and a missing floor support causing an overspan. Structural shifts in the home already have occurred that have required at least 3/8" be removed off the top of one door so that it could be closed. Also there has been, and is, water under the house as the result of an improper drainage situation, and as a result, there is an ineffective vapor barrier condition. It is now over 8- months, and we, the OWNER, refuse to BE PUT OFF ANY LONGER. Your INACTION AS THE BUILDER, DENYING THERE ARE PROBLEMS, OR REFUSING TO MAKE NECESSARY CODE CORRECTIONS AND THE NEEDED REPAIRS AS GUARANTEED UNDER THE BUILDER'S ONE -YEAR WARRANTY has got to come to a screeching halt! THEREFORE, before conditions /relations further erode : 1. All corrections shall be made by the BUILDER, under your construction responsibilities and by our homeowner's one -year warranty, within 21 days of certified receipt of this Notice, including re- inspections (without expense to the Owner). 2. Provide evidence to the Owner that the appropriate corrections have been made as evidenced bylege Ni i;;c -_ o . ,coT•r. c• E,0li4 iit having been issued and received ; and iz yv,; ,cohp co-r o-n L6:t te sent as notification to the Owner's lending institutions, and the involved governmental agencies. 3. That at least, the following construction corrections and warranty - covered repairs shall be satisfactorily made: A. Correct the foundation support and fire /life safety construction conditions. Assure a proper draft seal along wall footing on the inner garage wall. Also finish other dry wall coverage in the garage as requested and promised. Resolve the moisture situation. Put in place, the missing floor foundation support. - n. Re -seal tub /shower wall crack in upstairs bathroom. C. Completely repair poor plaster condition on the living room ceiling in the bay window section. Repair /Patch /Paint the plaster cracks and bulges (from popped nails) on spots throughout the house. Enclosures cc: FHA, Attorney, Home Builders Assn. State HB Bd., BBB ERNEST J. FORSMAN P. O. Box 6235 Aloha, Oregon 97006 (503) 684 -5638 December 8, 1988 Mr. and Mrs. Vogt 1110 S.W. 78th Tigard, Oregon 97228 Dear Paul and Pat: Upon conducting a partial structural inspection of"the crawl area and garage wall adjoining the staircase of your residence, I found that a support post for the floor beam system is missing. Also, a hazardous condition exists in that the garage firewall adjoining the staircase does not provide a fire -stop in accordance with Oregon Amended UBC Section 2516 2(c), page 203, and Section 4304 (a) and (b), page 613. This condition exists due to the misalignment of the concrete foundation wall to the wood- framed firewall. It, in my opinion, does not constitute a structural problem, but it does, however, result in a draft which does not comply with building codes. Sincerely,�� Ernest J. Forsman Oregon State Structural A Level Certification #3405 w _ HE � ORISSErTE 9iItDiRS INC. 7470 S.W. 76th • Portland, Oregon 97223 • 246 -8803 (0 Pat and Paul Vogt 1 December 1988 11128 S.W. 78th Avenue Tigard, Oregon 97223 RE: Final Check List Dear Mr. And Mrs. Vogt, Pat and I have discussed the items in your letter dated 11 -30 -88 and we feel that items 3 and 4 are warrantable but items 1 and 2 are not. We will schedule our drywall subcontractor to take care of items 3'and 4 as soon as possible. He will contact you and make an appointment. Thank you, Steve Girar• Warranty Mgr. cc: FHA Home . Builders Board • • Final Check List For the Builder. Herb florisette at 11100 SW :8th Avenue, Tigard, Paul'& Pat Uogt, e35 -555`1 1. Finish plastering walls in garage, foundation support and seal along wall footing on inner garage wall. 2. Re -caulk tubishower bead in upstairs bathroom 3. Repair poor piaster ,job on ceiling area above h, .y w.indom `i. Repair plaster cracks and popped rails on piaster wails " throughout house. 11;30/88 cc. • •