Loading...
Report / 7/ F /2 �9/ smt/ 1.5/NO�6 SIEMENS WATER TECHNOLOGIES 11606 NE 66th Circle, Suite 101 Vancouver, WA 98662 TRAINING AND 0 & M MANUAL REVIEW RECORD General Data Customer Name: WOLCOTT PLUMBING/THE KNOLL @ TIGARD PO #: 072010 - 25/072010 -26 Name Company � A.74 P/h Customer Key Contact: Jot cif ti � � Phone/Ext #: 3- 0 91-7 Pubvi Gig. a� � Attendees: X s" r c,V r 1 U �ri / At. Lc/ J / /had Siemens Water Teelinologies Custo er 2-/ //// ji Date Date Comments: 1/1 /'� f� /5'h 11 4A C PA I-! O &M Revised 5/10/96 SIEMENS WATER TECHNOLOGIES 5717 NE 121st Ave Vancouver, WA 98682 SIEMENS 2/16/2011 START UP REPORT CUSTOMER CONTACT NAME THE KNOLL AT TIGARD NAME JOE BRADSHAW ADDRESS 12291 SW KNOLL DRIVE PHONE 503 - 223 -6327 CITY /ZIP TIGARD OR, 97223 PROJECT# 105823/105824 UV SKID MODEL# SSUV -10 RECIRCULATION PUMP MODEL# CHI2 -20 UV MODEL D VOLTAGE 120 vac VOLTAGE 120VAC AMP RATING 9.8 FLA INTENSITY 254nM ACTUAL AMPS 7.1 AMPS OUTLET PSI 11psi ALSO FILTER INLET 10PSI FILTER OUTLET FLOW NA HP .5HP SPECIAL NOTES /INSTRUCTIONS UV LIGHT TO BE CHANGED EVERY 12 MONTHS. FILTER TO BE CHANGED EVERY 30 DAYS OR AT A DIFFERENTION PRESSURE OF 10 ABOVE STARTING POINT. 3 SIEMENS WATER TECHNOLOGIES 5717 NE 121st Ave Vancouver, WA 98682 2/16/2011 START UP REPORT CUSTOMER CONTACT NAME THE KNOLL AT TIGARD NAME JOE BRADSHAW ADDRESS 12291 SW KNOLL DRIVE PHONE 503 - 223 -6327 CITY /ZIP TIGARD OR, 97223 PROJECT# 105823/105824 BAG PREFILTER MODEL# BFNP11 316SS INLET OUTLET PRESSURE NA NA # OF HOUSINGS 1 ELEMENT TYPE 30 micron bag filter # OF ELEMENTS 1 TANK LEVELS ON OFF HIGH LEVEL ALARM 20 cm. SUMP PUMP FILL 61 cm. 20 cm. CITY WATER FILL 61 cm. 20 Cm. LOW LEVEL SHUT -OFF 124 cm. (DISTRIBUTION SKID) 124 cm. (UV SKID) SUMP PUMP MODEL# GRUNDFOS 96001542 VOLTAGE 230 VAC DISCHARGE NA 3 PHASE SPECIAL NOTES /INSTRUCTIONS FILTER SHOULD BE CHANGED OUT EVERY 30 DAYS OR AT 10PSI DP WHICH EVER COMES FIRST. 3 SIEMENS WATER TECHNOLOGIES 5717 NE 121st Ave Vancouver, WA 98682 SIEMENS 2/16/2011 START UP REPORT CUSTOMER CONTACT NAME THE KNOLL AT TIGARD NAME JOE BRADSHAW ADDRESS 12291 SW KNOLL DRIVE PHONE 503 - 223 -6327 CITY /ZIP TIGARD OR, 97223 PROJECT# 105823/105824 DISTRIBUTION PUMP(S) MODEL# CRNE 10 -2 VFD Pump & Motor, 2HP, 3Ph, 60Hz, 460/480V, TEFC, 42gpm ca 30psi VOLTAGE 480 V DISCHARGE 48 PSI AMP RATING 7.6 AMP OVERLOAD 20 AMP BREAKER ACTUAL AMP 5.2 AMP ROTATION CCW FLOW NA GPM PUMP PRIME YES BAG FILTER MODEL# BFNP11 316SS INLET OUTLET PRESSURE 48 48 # OF HOUSINGS 1 ELEMENT TYPE 50 micron bag # OF ELEMENTS 1 SPECIAL NOTES /INSTRUCTIONS FILTER TO BE CHANGED OUT EVERY 30 DAYS OR AT 10 DP WHICH EVER COMES FIRST. 3 FLA4 ot cro l (Q 8' SIEMENS WATER TECHNOLOGIES 5717 NE 121st Ave Vancouver, WA 98682 SNE ENS 2/16/2011 START UP REPORT CUSTOMER CONTACT NAME THE KNOLL AT TIGARD NAME JOE BRADSHAW ADDRESS 12291 SW KNOLL DRIVE PHONE 503 - 223 -6327 CITY /ZIP TIGARD OR, 97223 PROJECT# 1 0582 3/1 05824 UV SKID MODEL# SSUV -10 RECIRCULATION PUMP MODEL# CHI2 -20 UV MODEL D VOLTAGE 120 vac VOLTAGE 120VAC AMP RATING 9.8 FLA INTENSITY 254nM ACTUAL AMPS 7.1 AMPS OUTLET PSI 11psi ALSO FILTER INLET 10PSI FILTER OUTLET • FLOW NA HP .5HP SPECIAL NOTES /INSTRUCTIONS UV LIGHT TO BE CHANGED EVERY 12 MONTHS. FILTER TO BE CHANGED EVERY 30 DAYS OR AT A DIFFERENTION PRESSURE OF 10 ABOVE STARTING POINT. 3 • SIEMENS WATER TECHNOLOGIES 5717 NE 121st Ave Vancouver, WA 98682 SIEMENS 2/16/2011 START UP REPORT CUSTOMER CONTACT • NAME THE KNOLL AT TIGARD NAME JOE BRADSHAW ADDRESS 12291 SW KNOLL DRIVE PHONE 503 - 223 -6327 CITY /ZIP TIGARD OR, 97223 PROJECT# 105823/105824 BAG PREFILTER MODEL# BFNP11 316SS INLET OUTLET PRESSURE NA NA # OF HOUSINGS 1 ELEMENT TYPE 30 micron bag filter # OF ELEMENTS 1 TANK LEVELS ON OFF HIGH LEVEL ALARM 20 cm. SUMP PUMP FILL 61 cm. 20 cm. CITY WATER FILL 61 cm. 20 cm. LOW LEVEL SHUT -OFF 124 cm. (DISTRIBUTION SKID) 124 cm. (UV SKID) SUMP PUMP MODEL# GRUNDFOS 96001542 VOLTAGE 230 VAC DISCHARGE NA 3 PHASE SPECIAL NOTES /INSTRUCTIONS FILTER SHOULD BE CHANGED OUT EVERY 30 DAYS OR AT 10PSI DP WHICH EVER COMES FIRST. 3 SIEMENS WATER TECHNOLOGIES 5717 NE 121st Ave Vancouver, WA 98682 2/16/2011 START UP REPORT CUSTOMER ,CONTACT NAME THE KNOLL AT TIGARD NAME JOE BRADSHAW ADDRESS 12291 SW KNOLL DRIVE PHONE 503- 223 -6327 CITY /ZIP TIGARD OR, 97223 PROJECT# 105823/105824 DISTRIBUTION PUMP(S) MODEL# CRNE 10 -2 VFD Pump & Motor, 2HP, 3Ph, 60Hz, 460/480V, TEFC, 42qpm ca 30psi VOLTAGE 480 V DISCHARGE 48 PSI AMP RATING 7.6 AMP OVERLOAD 20 AMP BREAKER ACTUAL AMP 5.2 AMP ROTATION CCW FLOW NA GPM PUMP PRIME YES BAG FILTER MODEL# BFNP11 316SS INLET OUTLET PRESSURE 48 48 # OF HOUSINGS 1 ELEMENT TYPE 50 micron bag # OF ELEMENTS 1 SPECIAL NOTES /INSTRUCTIONS FILTER TO BE CHANGED OUT EVERY 30 DAYS OR AT 10 DP WHICH EVER COMES FIRST. 3 • ►pLAA .o10- 6-OI(o 7zq1 Ste✓ 141_o(1 Dr. Gary Noble From: Terry Proudfoot [ tproudfoot @wolcottplumbing.com] Sent: Thursday, March 03, 2011 7:14 AM To: Gary Noble Cc: Tom Twells Subject: FW: STARTUP REPORT AND TRAINING ATTENDANCE SHEET Attachments: Start -up Report The Knoll .pdf; Training Doc.pdf Good morning Gary, attached is the paper work you requested on The Knoll rainwater harvesting system. • From: Mbanugo, Nkechi (WT) [mailto:Nkechi.Mbanugo @ siemens.com] Sent: Wednesday, February 16, 2011 2:41 PM • To: Terry Proudfoot Subject: STARTUP REPORT AND TRAINING ATTENDANCE SHEET • Terry, Attached are the startup data report and training attendance sheet «Start-up Report The Knoll .pdf» «Training Doc.pdf» Please forward to the appropriate parties. • • Thank you, Nkechi Mbanugo Project Manager SIEMENS Water Technologies Corp. 601 South Snoqualmie Street Seattle, WA 98108 email: nkechi.mbanugo @siemens.com office phone: (206)267 -3512 cell phone: (206)617 -0651 fax: (206)329 -0712 www.siemens.com/water Confidentiality Note: This e -mail message and any attachments to it are intended only for the named recipients and may contain legally privileged and /or confidential information. If you are not one of the intended recipients, please do not duplicate or forward the e-mail message and immediately delete it from your computer. 1