Loading...
Report 4/1/2011 1:24 PM carison 'resting Inc. -> ib035Z43b81 1 Fax Attention to:- From: - Name: 1- 503 - 624 -3681 Name: Emily Helm Company: Carlson Testing, Inc. Date: 04/01/2011 Telephone: 503 -684 -3460 Time: 01:24:13 P Pages: 2 RE: Final Summary Letter(Fisherman's Marine & Outdoor - Pallet Racking / Permit #BUP2011 -00014 / T1104093) Comments /Notes: This is the Final Summary Letter for: Project: Fisherman's Marine & Outdoor - Pallet Racking Address: 10355 SW Cascade Avenue - Tigard, OR Permit #: BUP2011 -00014 Please call if you have any questions. Emily Helm Office Assistant Carlson Testing, Inc. Phone (503) 684 -3460 Fax (503) 670 -9147 The information contained in this email is intended for the individual or entity to which it is addressed. Its contents (including any attachments) are confidential and may contain privileged information. If you are not an intended recipient you must not use, disclose, disseminate, copy or print its contents. If you receive this email in error, please notify the sender by reply email and delete and destroy the message. Bend Office (541) 330 -9155 Geotechnical Office (503) 601 -8250 C arlson Testing, Inc. Eugene Office (541)345 -0289 Salem Office (503) 589 -1252 Tigard Office (503) 684 -3460 Special Inspection FINAL SUMMARY LETTER Date: April 1, 2011 Job #: T1104093 City of Tigard 13125 SW Hall Blvd Tigard, OR 97223 -8199 Attn: Building Department Re: Project Name: Fisherman's Marine & Outdoor — Pallet Racking Address: 10355 SW Cascade Avenue — Tigard, OR Permit #: BUP2011 -00014 Dear Sir or Madam: This is to certify that in accordance with Section 1704.1.2 of the International Building Code, we have performed special inspection of the following item(s) per our inspection reports only: Installation of Expansion Anchors All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. Under all circumstances, the information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. . If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. IV45710(..AA-ka Neil S. Shannon Project Manager NSS /eah cc: Fisherman's Marine & Outdoor — Steve Wills swill @fishermans- marine.com City of Tigard Building Division Eaton General Construction — Eric Eaton Mail / Fax: 503- 489 -0550 P:\Projects\Genera1\201111 Final Letter.doc Bend Office (541) 330 -9155 Geotechnical Office (503) 601 -8250 Inc. Eugene Office (541) 345 -0289 Carlson Testing, n Salem Office (503) 589 -1252 Tigard Office (503) 684-3460 Daily Report of Proprietary Anchors Client: FISHERMANS MARINE & OUTDOOR - STEVE WILLS Project: FISHERMANS MARINE & OUTDOOR - PALLET RACKING CTI Job #: T1104093. Address: 10355 SW CASCADE AVENUE TIGARD OR Jurisdiction: TIG_ARD CTI representative S . HOPPE OBOA 791 was on site this date Mar . 31, 2011 to perform Special Inspection for: Permit BUP2 011 -0 0 014 DFS #(s) PO Number: SCOPE OF INSPECTION Location of proprietary anchors inspected [to include grid lines, elevations (floors) and drawing details]: 1. Checked in with superintendent or client representative. **NAME OF PRODUCT BEING INSTALLED: PORTEOUS E RIC Dame' FASTENER WEDGE ANCHOR. Company: EATON GENERAL CONSTRUCTION 2. Inspection was "IBC" ® Continuous Periodic WAREHOUSE RACK ANCHOR BOLTS AT BASE PLATE (INSTALLED PRIOR TO ARRIVAL). FASTENER USED WAS NOT FASTENER STATED ON PLANS. PLANS STATE 1/2" PROPRIETARY ANCHORS ANCHORS, 3-1/2" MINIMUM EMBED, (2) PER LEG. (4) YesNoN /A PER LEG AND 5 -1/2" ANCHOR WAS USED. 1. Reviewed previous inspection reports? X (CONTINUED IN NOTES) 2. Reviewed evaluation report? Verified following items meet manufacturer's REPORT SUMMARY published installation instructions. 3. Verified minimum embedment depth of the 1. Work inspected was: ® Completed 0 In progress anchors. x 4.Verified installation of the anchors. 2. Completed work inspected was not in compliance with X IN Approved plans and specifications ❑ Shop drawings 5. Verified anchor diameter. x 6. Verified steel grade. x RFI 0 Design change Submittal N/A 7. Verified hole diameter. x Document #(s) Dated: 8. Verified type of drill bit used. x 9. Verified hole cleaning method. x 3. Noncompliance item(s) were noted this date, details on — 10. Verified adhesive application. x following page(s). Yes No N/A 11. Verified edge distance. x 4. Noncompliance item(s) were reinspected this date, details 12. Verified spacing. x on following page(s). 1=1 Yes No N/A 13. Verified installation torque. x ❑ Conform ❑ Remain in progress Evaluation report number 8,z. date: Report(s) findings were discussed and left with NONE ERIC of EATON GENERAL CONSTRUCTION Name of product being installed Batch Number N/A Expiration Date N/A Based on the Code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. See additional report page(s). 0 Distribute attachments. Page 1 of Daily Report of Proprietary Anchors For: 03/31/2011 CTI Job #: T1104093. Project: FISHERMANS MARINE & OUTDOOR - PALLET RACKING Notes: (CONTINUED FROM LOCATION) THE FOLLOWING NON - COMPLIANCE ITEMS WERE ADDED: -NCL #1: PER PLAN - WAREHOUSE ANCHOR BOLTS TO BE KWIK BOLT TZ, 1/2" DIAMETER - 3 -1/2" MINIMUM EMBED. BOLTS INSTALLED WERE PORTEOUS FASTENER CO WEDGE ANCHORS - 1/2" DIAMETER AND 5 -1/2" LONG. -NCL #2: PER PLAN - (2) ANCHORS PER LEG TO BE INSTALLED. (4) ANCHORS PER LEG WERE INSTALLED, TORQUE UNKNOWN. 3/31/11 (UPDATE): NCLS #1 & 2 HAVE BEEN CLEARED. THEY ARE APPROVED AS BUILT PER RFI -002 & PROJECT MANAGER NEIL SHANNON PHONE CONVERSATION WITH AOR JERRY CONDUFF OF CONDUFF ARCHITECTURE. In some cases more than one box may be checked for a given item on the front page. Our reports pertain to the material tested/inspected only. Information contained herein is not to be reproduced, except in fi without prior authorization from this office. Under all circumstances, the information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. Reviewed By: Neil Shannon Review Date: 04/01/2011 SH /EAH FISHERMANS MARINE & OUTDOOR - STEVE WILLS SWILLS @FISHERMANS - MARINE.COM TO: CITY OF TIG_ARD BUILDING DIVISION EATON GENERAL CONSTRUCTION - ERIC EATON MAIL /FAX /503- 489 -0550 Carlson Testing, lnc. Iticonipleted Items List (NCL) Apr 04, 2011 T1104093. Project Name: FISHERMANS MARINE & OUTDOOR - PALLET RACKING Project Address: 10355 SW CASCADE AVENUE TIGARD OR Permit No: BUP2011 -00014 P.O. No: Project Manager: NEIL S . SHANNON Item # Insp. Dale Item Description Compliance CTI Sign -Off Date Corrected 1 SH 03/31/2011 PER PLAN - WAREHOUSE ANCHOR BOLTS TO BE KWIK BOLT APPROVED AS BUILT PER NEIL S. SHANNON 03/31/2011 TZ, 1/2" DIAMETER - 3 -1/2" MINIMUM EMBED. BOLTS RFI -002 & PHONE INSTALLED WERE PORTEOUS FASTENER CO WEDGE ANCHORS CONVERSATION WITH AOR - 1/2" DIAMETER AND 5 -1/2" LONG. JERRY CONDUFF OF CONDUFF ARCHITECTURE. 2 SH 03/31/2011 PER PLAN - (2) ANCHORS PER LEG TO BE INSTALLED. APPROVED AS BUILT PER NEIL S. SHANNON 03/31/2011 (4) ANCHORS PER LEG WERE INSTALLED, TORQUE RFI -002 & PHONE UNKNOWN. CONVERSATION WITH AOR JERRY CONDUFF OF CONDUFF ARCHITECTURE. FISHERMANS MARINE & OUTDOOR - STEVE WILLS TO :CITY OF TIGARD BUILDING DIVISION EATON GENERAL CONSTRUCTION - ERIC EATON Page: 1