FIELD INSPECTION REPORT
DATES COVERED: October 6, 2010
PROJECT: Express Store #2049 @ Washington Square — Tenant Improvement
ADDRESS: 9585 SW Washington Square Rd — Tigard, OR
INSPECTOR: L. Warfield — COP#601, WABO #WAR049960, OBOA #361, ICBO #0870272
I 10 -06 -10 - Grouting
As requested, CTI representative was on site to observe grout infill of an existing CMU wall on grid 26 at new
opening location (refer to detail `B' on sheet S061). Contractor discovered that existing CMU wall is partially
grouted at 2' on center, vertically. The detail on sheet 6.1 specifies all cells to be fully grouted above the new
opening. Holes were cut into the empty cells at 2 course down from the beam on grid 26 at roof line, for the
width of new opening. Cells wee filled with a 3/8" grout from Knife River (mix #60N3R2S0 with intrusion aid
added at plant). Height of grout pour was approximately 16'. Slump was approximately 9 ". Grout was placed
with a line pump and was not vibrated. There were no samples cast as these were no CMU block to make
grout samples per ASTM methods.
* ** CHECK ONE BOX ONLY*** YES NO
1. This is a preliminary inspection only. — OR —
2. The work inspected conforms to acceptance criteria listed above. If "No," the portions of the work that
are non - conforming items are clearly stated above and will be added to the NCL. Remaining portions ❑ ❑
of the work, which are not preliminary in nature, are to be considered as conforming.
Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced,
except in full, without prior authorization from this office. Under all circumstances, the information contained in
this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this
report is prepared. No party other than those to whom CTI has distributed this report shall be entitled to use or
rely upon the information contained in this document. If there are any further questions regarding this matter,
please do not hesitate to contact this office.
Respectfully submitted,
CARLSON, ESTING, INC.
/ "
Jame-/" . Hietpas
Proj: Manager
/
/
L! / / dk
c. Horizon Retail Construction — Jimmy Guardalabene
City of Tigard Building Division
Paul J Ford & Company
Shremshock Architects Inc
10 -06 -10 fr 129 doc