Report FROM : THE JAMES L GROVES CO. "PHONE'NO. : 1 503 643 3659 P01 -_ /✓I 5 5- 00113 e I1 Inc. !a �� Construction Inspection & Related Tests Carlson Testing, r /3 5 4> Geotechnlcal Consulting June 12, 1995 P0. Box 23814 Tigard. Oregon 97281 Phone (503) 6843460 CTI #95-3451 _ FAX (503) 684 -0964 Designers NW 125 S.W. Hemlock Street _ Dundee, Oregon 97115 PILE OBSERVATION REPORT BATTALIA RESIDENCE - 135TH AND FERN TIGARD, OREGON At your request, Carlson Testing Inc. (CTI) provided observation of pile installation and load testing at the above single- family home. Pile support was recommended by CTI due to the presence of about 10 to 15 feet of uncompacted fill over the lot. A total of thirty one, 3 -inch diameter driven steel pipe piles and eleven, 4 -inch diameter were driven with an 850 ft -lb impact hammer at more than 500 strikes per minute. CTI observed installation of several of these piles on June 6th and 7th and tested downward loading capacity on one 3 -inch and one 4 -inch diameter pipe pile. The observed piles were terminated when penetration rates reached less than 1 inch penetration in 10 to 15 seconds. Pile lengths reportedly ranged from 22.5 to 44.5 feet. The load testing was performed by jacking on top of the pile against a 43,000 lb trackhoe. The load vs. deflection was recorded. Less than 0.2 inches of deflection was recorded at each pile at maximum sustained loads of about 18 to 19 tons before the trackhoe was lifted. The load Lest data is tabulated below: Pile #27 (3" diam.,34.5 ft) Pile #35 (4 " diem., 28.5 ft) Deflection (in) Load (tons) Deflection (in) Load (tons) 0 3 0 5 .022 5 .006 7 .059 7 .024 9 _072 9 .042 11 .098 11 .060 13 - .122 13 .078 15 .147 15 .094 17 _174 M 17 .107 19 • TO: 1 CAt e FROM_ ('' . - D .._ VtC'C� V �� • t: 6 /1Y/t 54 C1 _ P cs. fir¢ , / aye Q� b INCLUDING 7 S l u Sp THIS P. c V4- - 72 7 1�° t� w►'r ,,,, Z FM A . 6 FG) #: PII1NF r• G V 'i !bS V \3 0 0 113 FROM : THE TAMES L GROVES co. — PHONE'NO. : 1 503 643 3659 P02 0 Page 2 of 2 \tf ` #95 -3451 ; CONCLUSIONS Based on the abrupt change in observed penetration rates, it is our opinion that all piles met practical refusal in bedrock well below the bottom of the existing fill and beneath native silt flood deposits. Based on our observations of pile installation and load testing, it is our opinion that the piles are capable of supporting allowable loads of up to 16,000 lbs. for the 3 -inch diameter pipe piles and 20,000 lbs. for the 4 -inch diameter pipe piles. Our reports pertain to the material inspected only. Information contained herein is noL to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. k'; 1474 ,\ ✓4# ,/ / - t1 1. � , j. } ., e 7 _ 6,..3o -g7 James D. Imbrie, P.E. Geotechnical Engineer cc: J2K Engineering