Permit • ... CITY' OF TIGARD MASTER PERMIT e'\ DEVELOPMENT SERVICES PERMIT # • MST97 -0174 ' _!, L 1 j i� . 13125 SW Hall Blvd., Tigard, OR 97223 503 639.4171 DATE ISSUED: 07 / 14 f 97 PARCEL: ES 1 O4BD- 0207500 SITE ADDRESS...:12810 SW 135TH AVE SUBDIVISION •HANDY ACRES ZONING R -6 BLOCK LOT •3c JURISDICTION: TIG Remarks: SF - Path 1 - --------------------------- --------------------- BUILDING - - ---- - _---- _ - -____ — - ______ REISSUE: STORIES • 2 FLOOR AREAS - - - -- BASEMENT...: 0 sf REQUIRED SETBACKS -- REQUIRED------- --- CLASS OF WORK.:NEW HEIGHT • 24 FIRST • 1430 sf GARAGE • 400 sf LEFT : 13 SMOKE DETECTRS: Y TYPE OF USE...:SF FLOOR LOAD • 40 SECOND...: 1407 sf _ FRONT : 24 PARKING SPACES: 2 TYPE OF CONST. :5N DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT • 7 OCCUPANCY GRP.:R3 BORN: 3 BATH: 3 TOTAL - - - -: 2837 sf VALUE..$: 196867 REAR • 90 - ---------- ------------------- __________________ PLUMBING - _______ ___________________ _______ ___ — __________ __ SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 1 RAIN DRAIN ft: 100 TRAPS • 0 LAVATORIES • 5 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 100 SF RAIN DRAINS: 1 CATCH BASINS..: 0 TUB /SHOWERS...: 3 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 1a,, BCKFLW PREVNTR: 1 GREASE TRAPS..: 0 OTHER FIXTURES: 0 -- — -------------------------- MECHANICAL - - — - ----- FUEL TYPES- --- ---_ -- FURN (1. ..: 0 BOIL/CMP ( 3HP: 0 VENT FANS • 4 CLOTHES DRYERS: 1 GAS FURN ) =100K ..: 1 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1 MAX INP.: 0 BTU FLOOR FURNRCES: 0 VENTS • 0 WOODSTOVES • 0 GAS OUTLETS...: 1 - ---------------------- -------- - - - - -- - ELECTRICAL - -- RESIDENTIAL UNIT -- - -- SERVICE /FEEDER - - -- - -TEMP SRVC /FEEDERS— -- BRANCH CIRCUITS -- -- MISCELLANEOUS — - -ADD'L INSPECTIONS - 1000 SF OR LESS: 1 0 - 200 alp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 5 201 - 400 amp..: 0 201 - 400 alp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0 LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 alp..: 0 EA ADDL BR CIR: 0 SIGNAL /PRNEL...: 0 IN PLANT • 0 MANF HM /SVC /FDR: 0 601 - 1',0a amp.: 0 601 +amps- 1m v: 0 MINOR LABEL -10: 0 1000+ amp /volt.: 0 - -- — - - -- — PLAN REVIEW SECTION ------ - - - - -- - Reconnect only.: 0 )=4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC 0CC: - - -- -------- - - - - -- — ELECTRICAL - RESTRICTED ENERGY — -------- - - ---- - - -- A. SF RESIDENTIAL -- -------- --- - -- B. COMMERCIAL- - --------- --- - -- -------- -- AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM..: 0TH: :: X BOILER HVAC • LANDSCAPE /IRRIG: PROTECTIVE GARAGE OPENER..: CLOCK • INSTRUMENTATION: MEDICAL • OTHR: •• HVAC DATA /TELE CO NURSE CALLS....: TOTAL B SYSTEMS: 0 Owner: -- -- - - -- — - -- Contractor: — --- - - - - -- - -- TOTAL FEES:$ 4511.86 BOSILJKA SARICH BOSILJKA INC This permit is subject to the regulations contained in the 12860 SW 135TH AVE 17184 SW SUGAR PLUM CT Tigard Municipal Code, State of Ore. Specialty Codes and all TIGARD OR 97223 ALOHA OR 97'.7 other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is Phone 4: 524 -9007 Phone 4: 642 -0833 not started within 180 days of issuance, or if the work is Reg D..: 009987 suspended for more than 180 days. ATTENTION: Oregon law ___ ---- ---- ___ --------------- __ __— requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-v10 through OAR 952 - 001- ' :. You may obtain copies of these rules or direct questions to OUNC by calling (503)246 -1987. - -------------------------------------------------------- _ REQUIRED INSPECTIONS - Erosion Contol Post /Beam Mechan Electrical Servi Gas' Line Insp Water Line Insp Building Final Grading Inspecti Crawl Drain Electrical Rough Gas Fireplace Appr /Sdwlk Insp Footing Insp PLM /Underfloor Framing Insp Insulation Insp Electrical Final Foundation Insp Mechanical Insp Shear Wall Insp Gyp Board Insp Mechanical Final Post /Beam Struct i Plumb Top 'Lit Low Voltage Rain drain Insp Plumb Final , , Issued By: 9 �,t♦ /� Permittee Signature. !C-' , _A __,,,a ++++++++++++++++++++++++++++++++++++++++++ + + + + + ++ + + + + + +i-+ + +0 + + + + + + + + + + ++ +++ Call 639 -4175 by 6:00 p.m. for an inspection needed the next business day III e Plan Check # '3 1 f- - TY QF TIGARD Residential Building Permit Application Recd By lig9k) .3175_ SW HALL BLVD. New Construction Additions or Alterations Date Recd S -11 ;CARD, OR 97223 Single Family Detached or Attached (Duplex) Date to P.E. 503- 639 -4171 Date to DST G - c `Q ' - :$03 -684 -7297 • Permit # - O ( 7 St Print or Type • Caned - 7-1 -1 67 17-Di Incomplete or illegible applications will not be accepted Name of Project - . Name Job . MLP110 [E kJ'k(J< /i2r, TEc� ar• Address Site Address Architect Mailing Address l�-R Sw��5 / ! /�'" !.e 4.4.5' Sg' //4- .ire 0 2-03- _ City/State Zip Phone • Name ( Q MfS�� 6 17 0 fS - C 6 - /// d4i i�4 - 5)7R c • Name Owner Mailing Address �— fa 6 o S W I..? S - f1 �E Engineer Mailing Address City/State Zip I Phone T c•iJRi) 9�r -2z3� sNICA 9 ° 7 _.._.._... _ 4 - City/State Zip • Phone Name '.general (3OSt Lj / k A /y// ` Describe work New X Addition O Alteration O Repair O n ontractor Mailing Address to be done: l7/q- SL(!_S /l a!/l1 g9Lo 64(Jt Additional Description_of Work: _ City /State Zip Phone L-O /f/- d'I E Q >oo1 6 X 0 533 ) 1., Oregon Const. Cont. Boa Lic.# Exp. Date // attach Copy of - 0 0 ? ,Q 7/ f 6 `/6 - 9/ PROJECT / �� �� 7 w Current COT Business Tax or Metro # Exp. Date _ , ti des VALUATION $ Name ( NEW CONSTRUCT ONO • - .chanical ,S17/ E44 /-/FAT [412- - i- -_9,W -r Sq. Ft House: Sq. Ft . Garage Sub Maiiing Address V--d 3 7 e ontractor P. o Roy laoo,2_ Corner Lot YES NO Flag Lot YES NQ City/State - Zip Phone J � C/7/_ ip.,Gl 0 0. E tilt -92 _ G Gf- e83,3 (check one) (check one) - , Oregon Const Cont. Board uc # Exp. Date t Restricted Audio /Stereo Burglar ttach copy of / -0 C J r .. 9 , Energy System 1 (D Alarm /0 Current COT Business Tax or Metro # Exp. Date Installation � / Garage Door ! 4 HVAC _. Licenses / c a 17 / f 10 - R`T 1 0 Opener '- System ' 0 • Name - (check all th I Other. . , / Plumbing PLc1,l9 ld/ r 6 - .Sy5i 44 CP.// /7RHT s apply) , V L Sub Mailing Address Will the electrical subcontractor wire for all YES NO Contractor i � p Lf f S T �, ,�, 1J2 restricted energy installations? X City/State Zip qr7! Phone Has the Subdivision Plat recorded? N/A Y NO Shc, R bt/Oo p r7q ' G gs 4.3 Oregon Const Cont. Board Lic.# Exp. Date Reissue of MST#: Solar Compliance Attach Copy of t.7 ii1,,, i R 3 -,Z2 - %,r (Calculation Attached) i Current Plumbing Lic. # Exp Da I hearty acknowledge that I have read this application, that the Licenses 3 - Q� /� j•� ! / , information given is correct, that I am the owner or authorized COT Business Tax or Metro # p. to agent of the owner, and that plans submitted are in compliance -• J0 - 6^ / -91 A with Oregon State laws Name Signature of •` en/ • g - nt Date Electrical Cf/yB (/ ,GfC 7'R,(G /Ii. _:i u# /. , _ . ' I �-30 -9 Sub- Mailing Ad Tess Contact` onNamy i 1 � / Phone # Contractor Igo . 1 U� L� -=�L •� Sd •G9 „tip 9 on FOR OFFI r 9U E • LY: City/State C'f}.(// �nRE I h g'7g Pat #: MaplTl.#: • O on Cons Cont. Board Lic.# Ez Date o t + - 2_ 6 \ LA - 9. +teach Copy of ; _' O 7/ /- j Setba is Zo�le: Solar. Current Electrical Lic. # Ex p. Date „ 16,, tlk - (c-1 Licenses , 3 -- /1.24 Engineering A pr val: Plann Approval: TIF: + COT B lsmess Tax or Aetro Exp., Date t ; e V x CO 1 111 L 4� OD ( 3 �'� i :1s pp.doc { east) 1/9 0)60/149 o i 1 - Permit # Account Description • Amount Amt, Pd. Bal. Due rnsf97 OW MST. Permit (BUILD) 173 SO 6" 675. .4 ' �, L .V Plumb. Permit (PLUMB) 0 2,25, 25 Mech. Permit - (MECH) " I" `E' . ELC /ELR Permit (ELPRMT) Z 7,5" . a 76' State Tax - - (TAX) ‘/ 03 -- 64 e, Bldg: 3,3. r/ - P lumb: / / . ;" t � . • ,, Mech. - -- -- . - ._._- -- -- - - -- -- ELC /ELR: /3, 1 ✓ Plan Check MST: ( BUPPLN) 2/13g , ° " '- // / r9,. ' Plumb: ' (PLMPLN) Mech: (MECPLN) . �/ _z� -�. //, z; c P �8 P a 5' a6 .� CDC Review d pe, ptiJ LANDUS) E. ' g9' 2z - S4 7G s Sewer Connection • (SWUSA) -&�- -- — 4(00/ Y Reimbursement District . ( ) _ • -. Sewer inspection -- (SW1NSP) _ •�� - —3 C - Parks Dev Charge • (PKSDC) /DSO 1.7- / o 3 Residential TIF (TIF -R) /S 70 ' /570 Mass Transit TIF (TIF -MT) / Zv r / ZD Water Quality (WQUAL) "' ''ri'r ■ D Water Quantity (WQUANT) _ - Erosion Control Permit - ( ERPRMT) - Erosion Planck/USA (ERPLAN) °° "" ' Erosion Planck/COT (EROSN) 1/4_____2-- r ev Fire Life Safety (FLS) _ TOTALS: 1 .1Z s Z 6 5 L./ i:hfapp.doc (dst)1%9j : -1. SI 1. , .,/--- )-opi 1 tco L • Solar Balance Point Standard Worksheet Address Box A calculations: North -South dimension for the lot. Box A: This dimension is determined by finding the midpoint of the North lot line and drawing an intersecting line perpendicular to that point. - First, determine which property line is the North lot line. The North lot line is the line with the smailest angle from a line drawn east -west and intersecting the northern most : • point of the lot. 45° . woman v� w N North -South Dimension for Lot: Measure the distance from the midpoint of the North tot line to the South lot line along the described line. a y� w. v. µ ° ms ► S� _ . _ m _ , .. __ _ feet N ,. , Box B calculations: Shade point height for your residence. Box B: 1. Determine whether measurements will be based on the peak or eave of your Which describes structure. The orientation of the ridge is also important.-_ -------- ------ ,...,_ w __. your residence? la: If the roof line runs North-South, measurements will (circle one) Maw be based on the peak of the roof. . corn: uuu AMU *CM .--► / IA 1B l NOP 1 b: If the roof line runs East -West and the roof pitch is less than 5/12, measurements will be based on the eave. s • • 1c: If the roof line runs East- -Nest and the roof pitch is 5/12 cr steeper, measurements will be based on the , . n peak. sCo. SmoCt Box B. continued Box B: 2. measure change in elevation from front property line to finished floor elevation. If the lot slopes up from the front lot line to the foundation, the figure is positive. If I the lot slopes down from the front lot line to the foundation, the figure is negative. ft 3. Measure distance from finished floor elevation to the affected peak/eave. + 27' 0f, ft 4. If the roof line runs North - South, deduct three feet If the roof line runs East -West, - ft deduct nothing. - S. Subtract one foot for each foot of difference in elevation from the front property line to the rear property line, if the lot slopes up from the front to the rear. If the lot has no slope or slopes up from the rear to the front, deduct nothing. _ ". ft 6. Total figure for box B: 0 2f:4 .-.pu/ ft Box C. Distance to the shade reduction line. Box C. 1. Measure the distance from the North property line to the foundation near the, , • 1 ? j ft affected peak/eave. . 2. Measure the distance from the foundation to the affected peak or eave. + I y ft • 3. ' Total figure for box C: ' . t . .:' .. • 2- ft it is most useful to draw a vertical line to represent the appropriate figure found in box 'A' and a horizontal Gibe to represent the appropriate figure found in boat 'C. The intersection of the vertical and horizontal lusts determines the value found in box 'O'. The value in box 'D' should be compared to the value in box 'B'; if the value in box 11' is lea than or equal to the value found in box 'O', then the building is in compliance with the solar balance code. If you have any questions, please contact us at 639 -4171, x304 or at the Community Development Counter. MAXIMUM PERMUTTED SHADE POINT HEIGHT (In Feet) ! . Distance to North -south lot dimension an feet) -. _. ..., shade 100+ 95 90 85 80 75 70 65 60 55 . 50 - 45 40 reduction fin from northern '. : . • int gnr fin fert4 70 - - ' 40 40 40 41 42 43 44 65 38 38 38 39 40 " 41 - 42 43 ' 60 36 ,36 36 37 38 39 40 41 42 . 35 34 _ • 34 34 35 36 37 38 39 40 41 30 32 32 32 33 34 35 36 37 38 39 40 4 3 30 30 30 31 32 33 34 35 36. 37 38 39 40 23 23 23 29 30 31 32 33 34 35 36 37 38 33 26 26 26 27 28 29 30 31 32 33 34 35 36 30 - 24_ 24 24 25 26 27 28 29 30 31 31 32 33 34 25 '2 22 22 23 24 25 26 27 (8[ 29 30 31 32 20 20 20 20 21 22 23 24 25 26 27 28 29 30 15 18 18 18 19 20 21 22 23 24 25 26 .27 28 10 16 _ 16 16 17 18 19 20 21 22 23 24 25 26 5 - 14 14 14 15 16 17 18 19 20 21 22 23 24 Box D. Maximum allowed shade point height: 2 °a. feet - - CU �, 28 4) key h:kdozirtancykvertarritsolar.c4o Revised 212 26,6 aorieeMiallail CITY OF TIGARD BUILDING INSPECTION DIVISION MST CI' --0 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 U b BUP (. P • 70 Date Requested 1 , ( AM PM BLD Location (2? 1 0 .(A) 13 5 ' v _-- Suite ll MEC Contact Person i((M Ph 5 " // — .70-0 7 PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN • Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof F ART FAIL PLU G Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL m.. Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Opheoach /Sidewalk Date - c" )-- - C V ( .6 Inspector �! Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. • 06/08/2000 Activities for Case #: MST97 -00174 . • 3:11:55 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA005 Application received 05/23/1997 B • RECD BON 06/03/1997 MSTA008 Permit Created 06/03/1997 B PASS BON 06/03/1997 MSTA010 Check for prcl. restrict. 06/03/1997 B MEMO BON 06/03/1997 Remember conditions of approval for MLP96 -0013 MSTA012 Plans routed to Plans Examiner 06/03/1997 B PASS BON 06/03/1997 MSTA026 Plans approved by Pln Examiner 06/03/1997 RT PASS BT2 06/03/1997 MSTA030 Reviewed plans routed to DSTS 06/03/1997 RT PASS BT2 06/03/1997 MSTA032 DST Post- Review Completed 06/06/1997 GEO PASS GEO 06/06/1997 Needs owner /contractor Bus Tax/METRO, CCb expires on • 6/14/97 - mech cont. CCB update, Bux Tax/METRO - plumb contractor CCB update - elect. contractor needs Sup Lic #. • MSTA700 Erosion Control lnsp 844 -8444 BON 06/03/1997 MSTA705 Footing lnsp 07/24/1997 TLP PASS J *H 08/17/1997 MSTA706 Foundation lnsp 07/29/1997 RB PASS J *H 08/18/1997 Post address: No post/beam inspection until erected. Provide adequate vents as per 1430 sq ft - provide w /in 3' of corners. MSTA710 Post/Beam Structural 08/11/1997 KS APP KBS 08/11/1997 MSTA711 Post/Beam Mechanical 08/11/1997 KS A/N KBS 08/11/1997 #-1- this in spection does not include gas piping MSTA713 Crawl Drain 08/11/1997 RAB PASS J *H 08/11/1997 MSTA717 PLM /Underfloor 08/07/1907 MS PASS MRS 08/07/1997 MSTA720 Mechanical Insp 11/03/1997 RC FAIL J *H . 11/10/1997 Not ready. MSTA722 Plumb Top Out 10/19/1997 MS PASS MRS 10/30/1997 MSTA723 Electrical Service 11/07/1997 MJR PASS MJR 11/12/1997 MSTA724 Electrical Rough In 11/07/1997 MJR PASS MJR 11/12/1997 Page 1 of 4 06/08/2000 Activities for Case #: MST97 -00174 3:11:55 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA725 Framing Insp 11/10/1997 RC FAIL J *H 11/12/1997 1. Min. tread depth on stairs must be 9- inches on circular stairs. 2. Maximum nose on tread is 1.25 inches. 3. Plans do not show a room above living room - resubmit plans for roof- ceiling -joist approval. 4. Fireblock stair on wall side and where stair wall exceeds 10 -feet ceiling by upstairs bath • in upstairs and mechanical chase. 5. Strap walls, entry where plates do not cross at bonus room. 6. Provide hanger on truss supported by girder truss. 7. Strap all other walls where plates do not cross intersecting walls. OK TO INSULATE. CALL FOR FRAMING REINSPECTION. MSTA726 Shear Wall Insp 06/30/1998 RC PASS J *H 07/01/1998 • MSTA727 Low Voltage 06/30/1998 RC PASS J *H 07/01/1998 MSTA735 Gas Line lnsp 08/12/1997 KS FAIL J *H 08/15/1997 Call for pressure test for gas piping after all piping has been installed. MSTA736 Gas Fireplace 11/18/1997 RB PASS • J *H 11/18/1997 MSTA740 Insulation Insp 11/14/1997 KS PASS J *H 11/14/1997 MSTA745 Gyp Board lnsp 11/19/1997 GL PASS J *H 11/19/1997 MSTA755 Rain drain Insp 08/11/1997 RAB PASS J *H 08/11/1997 Pending rip rap at outfall of rain drains. MSTA760 Water Line Insp 02/13/1998 WA PASS J *H 02/13/1998 PVC water service okay -- pressure reducing valve at meter location. MSTA765 Appr /Sdwlk lnsp 12/12/1997 MH PASS S *W 12/15/1997 MSTA790 Electrical Final 02/26/1998 BRP PASS B *P 02/26/1998 MSTA795 Mechanical Final 03/04/1998 RB FAIL J *H 03/04/1998 All appliances must be in working order. NOT READY MSTA797 Plumb Final 03/26/1998 TLP FAIL J *H 03/27/1998 Call for reinspection when water heater working. • • Page 2 of 4 • 06/08/2000 Activities for Case #: MST97 -00174 • 3:11:55 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA799 'Building Final 07/10/1998 RC FAIL ROC 07/10/1998 1. blocked found. vent at front of house must be cleared. 2. need full bearing for top of steps on porch. 3. vapor barrior • must cover entire underfloor. 4. • need handrail on one side of back stairs. 5.support vent for . " weight and displacement. 6.fill • all holes in gar. wall. MSTA080 (F) Ready to issue 07/01/1997 B MEMO BON 07/01/1997 Various elements of contractors licensing is expired. MSTA095 Issue plumbing signature form 08/01/1997 SW RECD S *W 08/01/1997 MSTA097 Issue electric signature form 07/24/1997 SW RECD S *W 07/24/1997 MSTA092 (F) Issue combination permit 07/14/1997 B PASS BON 07/14/1997 MSTA726 Shear Wall Insp 10/10/1997 KS FAIL J *H 10/11/1997 1. Provide MST#48 straps at rear bay and upper level at gable end. MSTA720 Mechanical Insp 11/10/1997 RC PASS J *H 11/12/1997 MSTA725 Framing lnsp 11/14/1997 KS PASS J *H 11/14/1997 1. Framing approved as per correction list of 111097, RC. 2. Item #3 on correction list (no floor load, attic access only). 3. Install eave baffles where missed. MSTA735 Gas Line lnsp 11/25/1997 KS FAIL J *H 12/09/1997 no pressure MSTA735 Gas Line lnsp 12/01/1997 KS PASS J *H 12/09/1997 MSTA704 Sewer Inspection 02/13/1998 WA PASS J *H 02/13/1998 3 -inch ABS Sanitary Sewer okay, tested to overflow. MSTA795 Mechanical Final 03/26/1998 TLP PASS J *H 03/27/1998 MSTA797 Plumb Final 04/15/1998 TLP PASS J *H 04/16/1998 Page 3 of 4 06/08/2000 Activities for Case #: MST97 -00174 3:11:55 PM • Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA799 Building Final 06/30/1998 RC FAIL J *H 07/01/1998 1. Remove organic material from underfloor. 2. Vapor barrier must cover entire floor and up wall 12- inches. 3. Max. spacing on guardrail inter -? is 4- inches. 4. Need guardrail and • handrail on porch steps. 5. Max riser height is 8- inches. 6. Pad for AC must be 3- inches above surrounding grade. 7. Fill all holes in exterior sideing. 8. Need permanent address on house. 9. Provide full bearing for top of stair jack - porch. 10. Need final USA approval. 11. Min. guardrail height from finished flor must be 36- inches. 12. Support vent for weight and displacement. 13. ? 14. Protect furnace and AC lines from vehicular damage. 15. Support gas line in garage. 16. Fill all holes in garage wall ceiling with approved material. 17. Need latch on door to underfloor. 18. All exterior doors on house must be weathertight. NOTE: Tread is 8- inches to 8 1/2 inches (ostly 8- inches.) MSTA780 «REINSPECTION» 07/10/1998 RC PAID DST 07/13/1998 2nd Failed final Paid 98- 307280 07/13/98 jsd MSTA799 Building Final 07/17/1998 RC PASS J *H 07/22/1998 MSTA050 Hold for 09/14/1998 JMT JT 09/14/1998 e-mail to Ron,Jean,Hap. Holding C/O for final on Sit97 -0175 and inspection on voided SWR97 -0175. Confirm when ready to process MSTA945 Request inspection research 06/08/2000 JMT DONE No Hold JMT 06/08/2000 MSTA202 Hold Release to Issued Status 06/08/2000 JMT DONE No Hold JMT 06/08/2000 site expired, sewer void MSTA960 (F) Issue Cert. of Occupancy 07/17/1998 RC DONE No Hold JMT 06/08/2000 Page 4 of 4