Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
r CITY OF TIGAR® MASTER PERMIT PERMIT #: MST2000 -00087 iA DEVELOPMENT SERVICES D I N A L DATE ISSUED: 04/03/2000 �`�' e 13125 SW Hall Blvd., Tigard, OR 97223 (50�3914� • SITE ADDRESS: 12880 SW 134TH AVE .PARCEL: 2S104AC -11700 SUBDIVISION: DEER POINTE ZONING: R -7 BLOCK: LOT: 008 JURISDICTION: URB REMARKS: New SF - Path 1 BUILDING REISSUE: STORIES: 2 FLOOR AREAS REQUIRED SETBACKS REQUIRED CLASS OF WORK: NEW HEIGHT: 19 FIRST: 1,040 sf BASEMENT: 0.00 sf LEFT: 8 SMOKE DETECTORS: Y TYPE OF USE: SF FLOOR LOAD: 40 SECOND: 770 sf GARAGE: - 422 sf FRONT: 20 PARKING SPACES : 2 TYPE OF CONST: 5N DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT: 12 VALUE: -$ 136,338.66 ' OCCUPANCY GRP: R3 BDRM: 3 BATH: 3 TOTAL: 1,810.00 sf REAR: 29 PLUMBING SINKS: 1 WATER CLOSETS: 3 WASHING MACH: 1 LAUNDRY TRAYS: RAIN DRAIN: 100 TRAPS: LAVATORIES: 4 DISHWASHERS: 1 FLOOR DRAINS: SEWER LINES: 100 SF RAIN DRAINS: 1 CATCH BASINS: TUB /SHOWERS: 2 GARBAGE DISP: 1 WATER HEATERS: 1 ' WATER LINES: 100 BCKFLW PREVNTR: 1 GREASE TRAPS: OTHER FIXTURES: MECHANICAL FUEL TYPES FURN < 100K: 1 BOIL/CMP < 3HP: VENT FANS: 4 CLOTHES DRYER: 1 GAS FURN > =100K: UNIT HEATERS: HOODS: 1 OTHER UNITS: 1 MAX INP: btu FLOOR FURNANCES: VENTS: n WOODSTOVES: GAS OUTLETS: 1 ELECTRICAL RESIDENTIAL UNIT SERVICE FEEDER TEMP SRVC /FEEDERS BRANCH CIRCUITS MISCELLANEOUS ADD'L INSPECTIONS 1000 SF OR LESS: 0 • 200 amp: 0 - 200 amp: W /SVC OR FDR: 1 PUMP /IRRIGATION: PER INSPECTION: EA ADD'L 500SF: 201 • 400 amp: 201 - 400 amp: 1st W/O SVC /FDR: 00 SIGN /OUT LIN LT: PER HOUR: LIMITED ENERGY: 401 • 600 amp: 401 - 600 amp: EA ADDL BR CIR: SIGNAL/PANEL: IN PLANT: MANU HM /SVC /FDR: 601 - 1000 amp: 601 +amps- 1000v: - MINOR LABEL: 1000+ amp /volt : PLAN REVIEW SECTION Reconnect only: > =4 RES UNITS: SVC /FDR > =225 A.: > 600 V NOMINAL: CLS AREAJSPC OCC: ELECTRICAL - RESTRICTED ENERGY . A. SF RESIDENTIAL B. COMMERCIAL AUDIO & STEREO: VACUUM SYSTEM: AUDIO & STEREO: FIRE ALARM: INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM: OTH: BOILER: HVAC: LANDSCAPE /IRRIG: PROTECTIVE SIGNL: GARAGE OPENER: CLOCK: INSTRUMENTATION: MEDICAL: OTHR: HVAC: DATA/TELE COMM: NURSE CALLS: TOTAL # SYSTEMS: Owner: Contractor: TOTAL FEES: $ 2,005.72 • BRADLEY T MILLER CONTRACTOR BRADLEY T. MILLER CONSTRUCTIOTTigaIga rd d Municipal subject to the regulations contained C o i the Codes 17132 SW 123RD AVE 17132 SW 123RD AVE pal Code, State of f O OR. R. Specialty Cs and TIGARD, OR 123RD TIGARD, OR 123RD all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if • work is not started within 180 days of issuance, or if the work is suspended for more than 180 days. ATTENTION: • Phone: Phone: 639 -3533 Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set Reg #: LIC 124720 forth in OAR 952 - 001 -0010 through 952 - 001 -0080. You may obtain copies of these rules or direct questions to OUNC by calling (503) 246 -1987. REQUIRED INSPECTIONS . Erosion 844 -8444 Post/Beam Mechanical Ftng Drain Bsm't Walls Framing Insp Rain drain Insp Mechanical Final Sewer Inspection Underfloor insulation Mechanical Insp Shear Wall Insp Water Line Insp Plumb Final Footing Insp Crawl Drain /Backwater Plumb Top Out Low Voltage Appr /Sdwlk Insp Final inspection Foundation Insp Footing /Foundation Dr: Electrical Service Gas Line Insp Urb St Tree Certif Ltr R Building Final Post/Beam Structural PLM /Underfloor Electrical Rough In Gas Fireplace Electrical Final r • f� �� • Issued By : / / ` Permittee Signature : - 1'' _��_ 7 Call (503) 639 -4175 by 7:00 p.m. for an inspection needed the next business day CITY t RD R�enliat Building Permit appiiC,at on cue 3 - y 9 Reed`By X 43125 SW HALL BLVD. New Structinn • Date Recd 3 -1-/ -cx� TIGARD, OR 97223 Single Family Attached D ate to P.E. 17-,,2217---,�rx,0 V 503 - 684 -7 7� D ate to DST Zoe F 503 -684 -7297 Permit # _ V9 7 Print or Type Called 1 )I Incomplete or illegible applications will not be accepted of Projef 1 / _ Tcm M i l ler E�� (deg - lin�ddress • Job ��r rOl.1'1 L� (.U� i s S fe A res Architect i I160X 44146 Address l i I 1 1 �,, 1 .� YV 1 U 1 A YP.. City/State , Phone m iadliz 7 Mtilwr ()Ant.. " Cj nlyo (0 25- 455g � e Owner Mja -iiin ddr Q'"/ JUm M'►1IP.r' 7)1 alVie r 1 1 I Z � J Y11 � 23r Ave. .. ailin Address �y/State Phone_ Engineer X �{yG I r N etizz Cp 2B -35 3 !State Zip Phone General C ( '1 - 111 -10 6525 Contractor 7adi T Mi I Cont. Describe work New Cy' Addition 0 Alteration 0 Repair 0 ail' ddre to be done: Prior to permit 1 , 2, 3(,) 1 . rd Aye. Additional Description of Work: � j /y • issuance, a copy �' /State Phone / !_t4, Oath irn of all licenses Ti ()Q r d O > e _ Il22L 1n39 -3Z53 - are required if Oreg Const: Cont. Board Exp. Date PROJECT to expired in COT Lic.# 1 2 i li20 1dliOIOI VALUATION $ 13 3 �� - database Mechanical Name NEW CONSTRUCTION ONLY: Sub- c A ideatug Sq. Ft. House: Sq. Ft. Garage , / Contractor Mailin Address � ? Prior to permit „L.550 5E Olin., 21 , Indicate the restricted energy installation by the electrical issuance, a copy tate Zip Phone subcontractor in the following areas t !S of all licenses 9 7 1 ) (953 -$ 2-214 Restricted Audio /Stereo are required if Oregon Co t. Cont. Board Exp. Date Energy System Alarms expired in COT Lic.# �\ Installations Vacuum Irrigation database � � 039 10 -17 - W System System Plumbing Name (check all that Other: Sub- A i A 1 1 • apply) . Contractor Mailing Address c' / Number of Units in Building 1 ss Unit Number Designation ✓ J e' / v "t- Has the Subdivision Plat recorded? N/A YE NO Prior to permit C y to Zi one a$ 3q I issuance, a copy i Or N/A Y2/2-3 • l n o6 9 l of all licenses are Oregon Const. Cont. Board Exp. Date required if Lic.# 2_� 8 6 I hearby acknowledge that I hd this application, that the expired In COT V y have rea s a pp database Plumbing Lic. # / 0 Exp. Date � information given is correct, that I am the owner or authorized agent of the owner, and -3 c i' 14 16 (0 13 Oregon State lawshat plans submitted are in compliance with Name Si m .- ne !Agent Date 2- i • 00 Electrical Snter.5tate Elect ...... act me Phone Sub- Mailing Address /P39-3533 Con PO Box 73'4 2-- Pr�n 1�1 i 11er City/State Zip Phone (.5O3) • Prior to pa copy heiZ O� q 393 - 22.2 Issuance, a co 3 FOR OFFICE USE ONLY: of all licenses are Oregon Const. Cont. Board Exp. Date plat #: Map(fL #: • required 'rf Lic.# expired in GOT � " I 'L l 9 .5 .00 1-2-k- 2 1 t 7 q. & - ) 100 database ElectrI,L�c. l t .5q fix. 'n/'0 ^ SetbaFks:,� � Zone: R _ � Electrical Supervisor in Lic. # Ex n. Dat En eeringg Approval: Planning Approval: TI F: 1y 16.07.01 - l ,( AAA ; - Z7 - 2 0, 9 tifr /far - 1 ' L A f sewer age SANITARY* D J LI agency J 155 N. First Ave., Suite 270, Hillsboro, Or., 97124 SURFACE WATER _ J 503 648-8621 1 CONNECTION PERMIT ISSUE DATE 033100 EXPIRATION DATE 092700 EC EXP DATE 033102 PERMIT 110546 STRUCTURE ADDRESS 12880 PROJECT 8173 • STRUCTURE STREET SW 134TH AVENUE LOT 8 BLOCK TYPE CONNECTION— NEW OF DEER POINTE TYPE INSTALLATION— (19) BLD SWR/ERO CON /Stec TYPE OCCUPANCY— (1 ) SINGLE FAMILY PARCEL 291 4AC 11700 QTR SEC 4316 MN 26742 OWNER BRADLEY T. MILLER BU ADDRESS 17132 SW 123RD AVENUE TREATMENT PLANT ROCKCREEK TIGARD OR 97 224 PHONE 639-3533 WATER DISTRICT TIGARD FIXTURE EQUIVALENT DWELLING ING RESIDENTIAL UNITS SERVICE UNITS 0,0 UNITS 1 SERVICE UNITS 1 • CONNECTION FEES SURFACE WATER DEVELOPMENT FEES SEWER CONNECTION 2300.00 ' WATER QUALITY 210400 LESS CREDIT < 210.00> • WATER QUANTITY 290.00 LESS CREDIT < 58,00 ?• EROSION CONTROL INSPECTION 40.00 PLAN CHECK 26.00 SUBTOTAL. 2300.00 SUBTOTAL 298.00 TOTAL 2598.00 APPL NAME JENNIFER PHONE .- ._..____....-___.__ AFFILLIATION REP • REMARKS DEER POINTE LOT 8 PROJ 8173 *24 HOUR NOTICE FOR EROSION CONTROL INSPECTIONS REQUIRED * * * ** Nuu b e JJr;c c0 l f f o r j SPELT ON--- _844 -8444 * * * * ** SIGNATURE 1p . �. ..GP Z . js...ti--:.0 ? ....L. .1.,L A.-:SA---.:.L _:.; E ................. ISSUED BY HUMPHREJ �d L: Permit Conditions: e applicant agrees to comply with all rules and regulations of the Unified Sewerage Agency, including those regarding erosion control. { A 24 -hour notice is required for erosion control inspections. The inspection request number is 844 -8444. When calling for an inspection, please refer to the permit, project and lot numbers. The permit expires one hundred eighty (180) days from the date of issuance. The Agency does not guarantee the accuracy of the location of side sewer lateral. 7/93 WHITE - USA, BLUE - Accounting, GREEN - Inspection, YELLOW - Customer • , . INSPECTED BY DATE COWTRACIOR/INSTALLER TYPE OF PIPE DIAMiTEA OF PIPE i • , inspector, Please sketch below or atth 8 01'6 following informatiom I Street & nearest cross street 2 Location of structure being ser0A 3 Route of service line from siluctdr to property line where it connects to the service lifer include length diameter of service line, depth at,J14: WOcture & property line, dimensthns referencing lifi4 f.(1 Structure, property lines and/or corners, etc. 4 North arrow • • 1900,03-31 08:13 #988 P.01/01 FROM 1, . FROM : - RI TZ EISENSTE IN PHONE NO. : 503 628 4560 Mar. 31 2000 09:55pm pt , L■ 37 ( .. . , . ... .:. ... :•.,... 44 ... ---:-. ' . Ven.tureProperties .. .c."• . ,,..„. INCORPORATED . . • . . . ... . . . • • . . • CTeating . • • . . . .: ., • . • . - ... , - • .. . • " ., . Tomonotirs .:. . ... . . • .. • • . :.: • , ., , , • • • ' • ommunicie • . • .-. , . . .. .. ....„.- -- : • •Macil...'“,:eAx.g% .. .. • . .. ... , - • . . .• • - .• • '. • • ,•Taday. • • . . • • • • . . ' . ' . . • . :... . • Trir,'- :. c',F T11 T6. . • • • /...- • .... •• -•• . Buile.J..c . .a... ilitpzilltr.eni, • • • . . . . ...-• ."- • ' • :` • • . • . ' • Re: .TR (ltz for lots I 54, 8 DezePsimnib.,- • -.. ... ,..- • ..: . .. •.-- 4. ; .. . : :.'_...,'. , - .1).i, wborriii - wiry t. . • • . • . - • 'y'criturc•P:cp.-1 inc. obtained Traffic kinr.NICIFCC Crc.xlix dOring Ttl,C, C.C ilf the • - ... • Dec/ 'Foit.g.4,1 stibdivision,. ■Alu.luts: andit.): Don MoriNstitu :Alm.= 'have, tailizerd ibust.: lultr.iilz :;•r 1 ...: . "... • .• . . $2,0 U, c•er lot when rzg,.i permit to constroitt homes. Vdr4. has now. Aoki K. . . .3 end 8 in Doer POitlie in iirtuilell T. Niiila Comir.Ictien en:: WifibCfl to convey the TiF credit • . ' • .'. .....- . ' ''' .' ' • . 1.,..I7'.:4' C.; i 0 for ea01. of thei:tt !els to 3rAdley 'r. rs.li!e flittaw. alt,i;pry V1:.f: ihrw . .• . . . . '. .. -- ' ;.' . • OW4c-T LT, intx i ,3 and 8 to u:4.4.-. tbc . .FIF , ert when ptriiimili.-:;tikii;v, „,-,..-!-.q ftv i : .. I ..- . . Sineoloiy. . 1 . .. . . . I . - . . .. i i . W--. • 1 . . • • . • . , .:. - . " .. -- ••:: Ksqly Ritz • • • • :.. • Vick; Prmideril, ' • . . 1) 5Li . . .,, . - . . •,. . 9---- • . • . . ... :::_.-,:•:.:, •,: _ .... • • • ....•.... .... .:. • . •,. .. .. rO• . („,,,v)/(P 5. .•::•. ,:. • . ,9_,..t. . L /c). _• • . . . . . • ... • s... . • ... ..:.: . . ,,. , , • ... • •. . .,...:..„.. ............. 4230 Galewood Street, Suite 100 • Lake Oswego, OR 97035 • 503.387,7600 • fax 503,387.7617 5 • . - . .:. ..,. , . . . • • CITY OF TIGARD 13125 S.W. HALL BLVD. TIGARD, OR 97223 • IMPORTANT PERMIT NOTICE RECEIVED INTERSTATE ELECTRIC INC APR 6 an PO BOX 7342 COMMUNITY DEVELUPMLm SALEM, OR 97303 -0068 Electrical Signature Form Permit #: MST2000 - 00087 Date Issued: 04/03/2000 Parcel: 2S104AC - 11700 • Site Address: 12880 SW 134TH AVE Subdivision: DEER POINTE Block: Lot: 008 Jurisdiction: URB Zoning: R -7 Remarks: New SF - Path 1 Your company has been indicated as the electrical contractor for the permit indicated above. In order for the electrical permit to be valid, the signature of the supervising electrician is required. Please have the appropriate individual from your company sign below and return this Electrical Signature Form prior to the start of the work to the address above, ATTN: Building Dept. No electrical inspections will be authorized until this completed form is received OWNER: ELECTRICAL CONTRACTOR: BRADLEY T MILLER CONTRACTOR INTERSTATE ELECTRIC INC 17132 SW 123RD AVE PO BOX 7342 TIGARD, OR 97224 SALEM, OR 97303 -0068 Phone #: 503 - 639 -3533 Phone #: MBL 393 -2223 Reg #: uc 117121 SUP 00 1479S ELE 24 -354C AN INK SIGNATURE IS REQUIRE • 1 . HIS FO' ►! X . L ��'.d /,- " ' 4 S'gnature of Sup rising Electrician If you have any questions, please call (503) 639 -4171, ext. # 310 CITY OF TIGARD 13125 S.W. HALL BLVD. TIGARD, OR 97223 IMPORTANT PERMIT NOTICE RECEIVED APR 0 6 2000 A + R PLUMBING INC 2967 SE MAPLE ST BY: HILLSBORO, OR 97123 Plumbing Signature Form Permit #: MST2000 -00087 Date Issued: 04/03/2000 Parcel: 2 S 104AC -11700 Site Address: 12880 SW 134TH AVE Subdivision: DEER POINTE Block: Lot: 008 Jurisdiction: URB Zoning: R - Remarks: New SF - Path 1 Your company has been indicated as the plumbing contractor for the permit indicated above. In order for the plumbing permit to be valid, please have the appropriate individual from your company sign below and return this Plumbing Signature Form prior to the start of the work to the address above, ATTN: Building Dept. No plumbing inspections will be authorized until this completed form is received OWNER: PLUMBING CONTRACTOR: BRADLEY T MILLER CONTRACTOR A + R PLUMBING INC 17132 SW 123RD AVE 2967 SE MAPLE ST -- .. TIGARD, OR 07224 HILLSBORO, OR 97123 Phone #: 503 - 639 -3533 • Phone #: 648 -2964 Reg #: LIC 00042286 PLM 34 -149PB AN INK SIGNATURE IS REQUIRED ON THIS FORM x Signature of Authorized Plumber . If you have any questions, please call (503) 639 -4171, ext. # 310 CITY OF TIGARD BUILDING INSPECTION DIVISION MsT ddo �7 24 -Hour Inspection Line: 639 -4175 Business Line: 639 - 4171 BUP Date Requested / 1 2 • AM PM BLD Location - -g l ! 7 Suite ( MEC Contact Person Q - 'i1 //1,! y Ph PLM 6 • Contractor Ph SWR BUILDING . ° s Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab Cam. /� '�—�" :SGT` IT Post & Beam -7 Ext Sheath /Shear d / 9 © =:Z. Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: i SS PART FAIL P UMBING • Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL, ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading • Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk 7-C Other Date 7 -C� - Inspector Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST AtiU0 -®doi7 24 -Hour Inspection Line: 639 -4175 +. Business Line: 639 -4171 BUP Date Requested 6 - 3 AM PM BLD Location 49- $'' / 3 y Suite MEC Contact Person hl /1/-61 Ph -r / 75' PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: ` �® Slab �G°'�'� < SIT Post & Beam !/ , Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line ,Smoke Dampers Final PA PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage F larm Fi ASS ART FAIL �5YTE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: / [ ] Unable to inspect - no access ADA Approach /Sidewalk Date 7 e' V InS actor `, 1111r./ ' Other Inspector Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION Msr tV19C,i• Gz)03 24 -Hour Inspection Line: 639 -4175 I,. Business Line: 639 -4171 ..... BUP Date Requested W e 0 AM PM BLD Location 4: gC U 7;J / ti Suite MEC V Contact Person Ph .20 ( (7 / PLM Contractor Ph SWR BUILDING � -_`; Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam 1'/ , Q �� Ext Sheath /Shear CAI/ ! /��/ Int Sheath /Shear / Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final P T FAIL U MBING • P Under Slab Top Out Water Service Sanitary Sewer R ' rains PART FAIL M CHANICAL • Post & Beam Rough In • Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Other oach /Sidewalk Date 77 3/ ( Inspector t! K Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. • v,` CITY OF TIGARD BUILDING INSPECTION DIVISION MST sa30°Oao87 24 -Hour Inspection Line: 639 -4175 o • Business Line: 639 -4171 BUP Date Requested r CP /t 0/06 AM PM BLD Location 1 2-$ D0 ) S"1 ` r ,, , Suite MEC Contact Person J -FCC Ph Lo 3q3C PLM Contractor Ph SWR BUILDING '. ` >a °. Tenant/Owner ELC Retaining Wall ELR Footing Access: . Foundation FPS Ftg Drain // �� SGN Slab Crawl Drain Inspection Notes: r�:.� � �1 Post & Beam / p SIT Ext Sheath /Shear — l � b Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler s� Fire Alarm ©k TO POO K Susp'd Ceiling Roof Misc: I Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SIT'` Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA 1 •ac i•ew` Date I I L CV Inspector Witit Ext +18 Fi PART FAIL DO NOT REMOVE this inspection record from the job site. • CITY OF TIGARD BUILDING INSPECTION DIVISION MST 200 Q`)0g 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 � BUP Date Requested S I ''/(,��yJ AM PM 2r BLD Location Suite MEC Contact Person li -e,{') nit ' "4 Ph 6 31" 35 PLM Contractor Ph SWR ILDIN _ Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain '� -�( SGN Crawl Drain Inspection Notes: n Slab //� SIT Post & Beam fi Ext Sheath /Shear Int Sheath /Shear Framin • Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc• a PAS PART FAIL BI NG Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date 31/el ev Inspector 010 " . Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 2- - -000 &7 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested yi-voo AM PM BLD Location ('7 ' D I 3L Suite MEC Contact Person ' ',/1Vl.rq �_ Ph C 3 / G 3533 PLM Contractor 41 4/44 ' 1- 7 119 -- ' Ph SWR BUILDING - Tenant/Owner ELC Retaining Wall ELR Footing Access: • Foundation FPS • Ftg Drain SGN • Crawl Drain Inspection Notes: Slab SIT Post & Beam ` Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler �� �'`�' — - Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL CTR L Service cf oT n U(3/8 ab Low Voltage Fire Alarm PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk ,r j Other Date - 0-0 Inspector • _ xt Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST ?An - 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested 5(1 00 AM PM BLD Location l 2) V 1 3 le ' Suite MEC Contact Person Ton YIAZ - - Ph Co 35 - 3S ?j3 PLM Contractor Ph SWR BUILDINGr ; Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing , . L Insulation Drywall Nailing / L� / Firewall ■ Fire Sprinkler 7 Fire Alarm Susp'd Ceiling / /// / — l .405c Roof Misc: `���� , Final PASS PART FAIL ZtUMBII] Post & Beam Under Slab o O Water Service Sanitary Sewer Rain Drains S PART FAIL CHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Date . 1 Inspector Ext Final PASS PART FAIL ' 0 NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST it 0 -0008 7 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Date Requested .5/ 17/03 AM PM BLD Location 1 � S gO 13 t S Suite MEC Contact Person �P,1)Y1 W-e , Ph (D 39-3.533 .PLM Contractor Ph SWR • , ® �: Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain Crawl Drain Inspection Notes: ^ SGN l 6 - 't1�mQ Is lab ,� SIT Post & Beam g (' /d o l ( S / f lartEr Ext S r (/ Insulation A Drywall Nailing Firewall Fire Sprinkler 1 j Fire Alarm N� q er Q Susp'd Ceiling V Roof Misc: • Final PASS PART J PLUMBING ° Post & Beam _ 2 I Top :Out Water Service Sanitary Sewer t Rain Drains ?dS1 � Final PASS PART FAIL Post & Beam h In Gas Line Smoke Dampers Final PASS PART FA ELECTRICAL ROUT CYO /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access Fire Supply Line ADA / J 7 / l � Approach /Sidewalk Date J `j — l U 6 Inspector ^ - � Ext J Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 201 OOo 7 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 1 BUP / Date Requested S// g /DO AM )'C PM BLD Location `"! '44 ) Suite MEC Contact Person jl ✓14c`A L Ph 60 ;q - 3S 33 PLM Contractor Ph SWR (611ILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: �, „ / i Slab � �0,/` L �` J SIT Post & Beam Ext Sheath /Shear Int heath /Shear ramm Insulation Drywall Nailing 4 /,2 AET Firewall Fire Sprinkler (4,/ Ete 1. Bv& te (57s. S ar Fire Alarm ©e 4,- t�rG Susp'd Ceiling -� Roof Misc: ei.71 �� 4-14o) Fi lg ti Z PART FAIL E'^N — 4 p 4 d'J Z/ eesci Q.ti d , 06 PLUMBING Post & Beam i • Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PA FAIL VIFCHANICA Post & Beam Cough II Gamine Smoke Dampers ART FAIL ` hTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Date /44 in Inspector /p - ,r_• Ext Final III PASS PART FAIL DO NOT REMOVE this inspection record from the job site. v e,p ITY OF TIGARD BUILDING INSPECTION DIVISION °2°a61 000(7 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 irj / - BUP IS VI7 Date Requested S`' 7"� 0 AM P M /(� G � BLD Location fd Suite - MEC Contact Person Ph PLM Contractor Ph SWR or - s (i ii ) ',- ` Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation Jv5( .?, ,)4' � FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam t E, - I" SI-- • - - 11 I – - . s rami . IL .. k t..../% t..../% / CA T C_e Le `–ki `-L. J insu ation Drywall Nailing ' C i V i . Firewall r- 2S , , (. C { t Q f( (:_ * Fire Sprinkler I • L .. _e C•'�� Fire Alarm �. • ! Susp'd Ceiling AN ' v �/ ,Q Roof ID 4 C /0 5-32-4- �7 ul&. 4 C--- S u c 4I t1--- Misc: Final �� -` ` 5 P ASS PART AIL � \ - C. _ • PLUMBING 7�, : c-"-SN Post & Beam , Under Slab ‘ri ‘NA-3 . Top Out Water Service S'" r • 'Lt./ 0 �y�t • Sanitary Sewer Rain Drains e 4 a AJ Q CI C!i tAA-X_ 5 • Final PASS PA5 FAIL - i L� y-1. ' CHANI a - ma oI s TS & I p ost & Ream ough n (. r `3 ( � � SG --r/L1 e ine _ V Smoke Dampers f. -, - "r-...••/ ( `'C_— _ /N Final - - -- — _ PASS PART ��, S ELECTRICAL M 11`,„,v--0,1,3 ✓!Service ea Ve_ . . / Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA �/� !� Other / heoach /Sidewalk Date /� Ins pector " `- �`` `°' Ex t' Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 7 — 07/0 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested 5// S AM PM BLD Location is O I 3 Suite MEC Contact Person !/ d / tL /L4 ( Col/ f • Ph PLM Contractor _eOb Ph ‘`7 - 2 SWR BUILDING __ � - Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS g Ft Drain SGN wl Drai X �f Inspection Notes: S SIT Post & Beam Ext Sheath /Shear • Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: F ia PART FAIL PLUMBING Post & Beam _ Under Slab Top Out fliain D•a Fi P PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ I Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access Fire Supply Line ADA Approach /Sidewalk Other Date --577 o Inspector i / Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 21DOU 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested S O D AM PM BLD e Location 12-1'1 0 1 / L , Suite MEC Contact Person 11 �P'�/L. Ph (P 3q- 3S 3 3 PLM Contractor Ph SWR BUILDING , . Tenant/Owner ELC Retaining Wall ELR • Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Framing Insulation 4 / -kS /G� _ 9 /) S / tion l-� / , Drywall � Drywall Nailing Firewall Fire Sprinkler r - Fire Alarm -C?; � a { C � Susp'd Ceiling U Roof Misc: �� —� `/L-AN , Final \ i 1 ' PASS PART FAIL PLUMBING /�� �n� ; /� Post & Beam Under Slab ( S 6� Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL C IIECHANIC4LD Post & Beam - ou• 11. _ Smoke Damper Final PASS PART FAI ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date O 5 0 Inspector Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION Msr Z -07 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BU Date Requested SHOO A0 c --- PM BLD. • Location 1ZgD I3L11 -. Suite MEC Contact Person Ph Le 6 /9 &I (7 PLM Contractor Ph SWR BUILDING ° : ° Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PAS ART FAIL CUMB Post & Beam Under Slab Top Out Water Service Sanitary Sewer F•": PART FAIL CHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA ) ` Approach /Sidewalk G j r � Other Date Inspector Ext, Final PASS PART FAIL DO N6 REMOVE.this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested - S / AM PM BLD Location 2-q g 0 � f � ' " -(1 -€. Suite MEC Contact Person ,T Y t-le Ph (0 39 -3S 3? PLM Contractor Ph SWR (0 Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath/ ar ath /Sh �� Framing % 4' 4/(� Insulation Drywall Nailing ,V4,4.- CAih c.= %rdaS Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PA RT AI PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk r ct Date Inspector nspeo t Other Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST _ 000 20 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 44/7://on BUP Date Requested AM PM BLD Location 12 0 I 3 J -e, Suite MEC Contact Person 04 014 4, Ph '7 T?'( / ? 7 PLM Contractor Ph SWR BUILDING. Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Apo Final I PASS ART FAIL f 'PLUMBI f Post & Beam Under Slab Top Out lat2r be pb' a n Dr Final i PASS PART MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers - Final - PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access Fire Supply Line ADA Approach /Sidewalk )7 7 Other Date `Inspector � Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION j 2000 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 f' Date Requested L7 /Z( /C�0 AM �C PM BLD Location 1 Z �i� ,� " ( �� - Suite MEC Contact Person en/I/P•1 p/v. Ph 6931-3S) PLM Contractor Ph SWR Tenant/Owner ELC Retaining Wall ELR • Footing Access: Foundation FPS Ftg Drain SGN r awl Dr. Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Dia ' i / / 1 At' ,/. , (/) .51 . Insulation o Drywall Nailing ► , mo`-� ba pe/) QsSGZ. �s Firewall • t Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Fin • _ PART FAIL UMBI H' ost & Bea no ab Top Out Water Service er .gtG , z or i �_ PART FAIL ANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach/Sidewalk Date Q' /Z 0 Inspector /1 E:? Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST 1'0D3 7 . 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 Date Requested u V AM �c PM BLD _Location [ 2 - ( ggD 1 -1 Suite MEC Contact Person C )2J V oC4/- Ph (L23 '9 -3S 3 PLM Contractor Ph SWR • UILDI Tenant/Owner ELC • Retaining Wall ELR Footing Access: Foundation FPS Ft: Drain SGN •l f-.►454' -:i Inspection Notes: Slab lir SIT .ost & B-. ��• Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Fina •AS -11 PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL QPost & Beam" Rough in Gas Line Smoke Dampers • Final A PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ • ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA /�" - � fe Approach /Sidewalk f-( �i� � � /J � ._ Other Date Inspector " �' Ext. Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION Z _ o �g -) 24 -Hour Inspection Line: 639 -4175 . Business Lin i4:, 639 171 I 4 BUP Date Requested YOD iS AM PM BLD tt�� Location I �- c� D %D I 3te _ Suite MEC Contact Person OUWAL Ph '7g i VOL PLM Contractor Ph SWR ILDIN Tenant/Owner ELC Retaining Wall oNA 0 ELR 9.0...p"` ivl Access: FPS .undatio, " Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Ina Sheath /Shear \ J\ /� C ,�: � /✓ �� g- �- v , Framing r d ` �'�- Insulation Drywall Nailing 7 Z-e1N- . - Fire wall \_ S .- , Fire Sprinkler ■ Fire Alarm Susp'd Ceiling Roof Z Misc: 4 Fin.. • � PART FAIL 1 Q • BING \ S Post & Beam — 7 Under Slab • Top Out \ Water Service / / ^/� ,......%/` Sanitary Sewer Rain Drains . ,C -r c ) C..."-- C 9/ Qom\ Final PASS PART FAIL ,„,, _ - •.. - MECHANICAL Post & Beam ' k ILIFI ` Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm - Final i _ S PART FAIL • 1 :: c fill /Grading Sanitary Sewer i 1 d Storm Drain All D e : , [ j Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin QJ! Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA /�, �/ Approach /Sidewalk • Date 4/ 1 3/ 0 ` Inspector 4. EXt > J .Il!111 p A4/, e o<GfM F'•: wie PART FAIL DO NOT REMOVE this inspection record from the job site. 6/15/00 Activities for Case #: MST20O0 -00087 7:07:02 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA005 Application received 3/21/00 KJP RECD No Hold BON 3/27/00 MSTA008 Permit Created 3/27/00 BON DONE No Hold BON 3/27/00 MSTA010 Check for prcl. restrict. 3/27/00 BON DONE No Hold BON 3/27/00 MSTA012 Plans routed to Plans Examiner 3/27/00 BON DONE No Hold BON 3/27/00 MSTA026 Plans approved by Pln Examiner 3/27/00 BT2 DONE No Hold BT2; 4/6/00 MSTA030 Reviewed plans routed to DSTS 3/27/00 BT2 DONE No Hold BT2 4/6/00 MSTA700 Erosion 844 -8444 No Hold RB 4/14/00 Approved on 4 -11 -00 by CPB. MSTA704 Sewer Inspection - 4/27/00 MRS FAIL No Hold AKJ, 4/27/00 not ready • MSTA705 Footing lnsp 4/13/00 RB PASS No Hold RB 4/14/00 Mono Pour. MSTA706 Foundation lnsp 4/13/00 RB PASS No Hold RB 4/14/00 Ufer tagged. I 1. Maintain seismic restraint req'mts as per approved plans , and engineering. 2. Provide adequate ventilation. 3. Place anchor bolts as per approved plans and engineering. MSTA710 Post/Beam Structural No Hold BT2 3/27/00 MSTA711 Post/Beam Mechanical No Hold BT2 3/27/00 MSTA712 Underfloor insulation No Hold BT2 3/27/00 . MSTA713 Crawl Drain /Backwater valve 4/21/00 RB PASS No Hold RB 4/21/00 MSTA714 Footing /Foundation Drain No Hold BT2 3/27/00 MSTA717 PLM /Underfloor 4/21/00 RB PASS No Hold RB 4/21/00 MSTA718 Ftng Drain Bsm't Walls No Hold BT2 3/27/00 MSTA720 Mechanical Insp 5/8/00 RB FAIL No Hold RB 5/8/00 1. POST ADDRESS> 2. Exhaust venting disconnected thru -out. 3. Fireplace not installed at time of inspection. 4. Soffit ductwork in garage. 5. Does return air upstairs suffice for the entire house? According to the contractor - Yes. MSTA722 Plumb Top Out 5/17/00 MRS PASS No Hold AKJ 5/17/00 1) house needs address • 2) missing nail plates clothes washer waste MSTA723 Electrical Service 5/17/00 CD PASS No Hold AKJ 5/17/00 MSTA724 Electrical Rough In 5/17/00 CD PASS No Hold AKJ 5/17/00 Page 1 of 3 6/15/00 Activities for Case #: MST2000 -00087 7:07:02 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA725 Framing Insp 5/17/00 RB FAIL No Hold AKJ 5/17/00 elec not app as of this date, 2nd notice to post address insp denied and terminated MSTA726 Shear Wall Insp 5/2/00 KBS FAIL No Hold AKJ 5/2/00 1) renail panels where nails are overdriven 2) nail gable ends MSTA728 Low Voltage No Hold BT2 3/27/00 MSTA735 Gas Line lnsp 5/8/00 RB PASS No Hold RB 5/8/00 Tagged- 380715 MSTA736 Gas Fireplace No Hold BT2 3/27/00 MSTA752 Rain drain Insp 4/21/00 RB FAIL No Hold AKJ 4/27/00 Not Ready. MSTA760 Water Line lnsp 4/27/00 MRS FAIL No Hold AKJ 4/27/00 not ready MSTA765 Appr /Sdwlk lnsp No Hold BT2 3/27/00 MSTA767 Urb St Tree Certif Ltr Recd No Hold BT2 3/27/00 MSTA790 Electrical Final No Hold BT2 3/27/00 MSTA795 Mechanical Final No Hold BT2 3/27/00 MSTA797 Plumb Final No Hold BT2 3/27/00 MSTA798 Final inspection No Hold BT2 3/27/00 MSTA799 Building Final No Hold BT2 3/27/00 = MSTA032 DST Post - Review Completed 3/31/00 BON DONE No Hold BON 3/31/00 MSTA080 (F) Ready to issue 3/31/00 BON DONE No Hold BON 3/31/00 Needs USA sewer permit and TIF voucher before issuing this permit. MSTA092 (F) Issue combination permit 4/3/00 KJP DONE No Hold KJP 4/3/00 MSTA095 Issue plumbing signature form 4/6/00 SLT RECD No Hold ST 4/6/00 MSTA097 Issue electric signature form 4/6/00 SLT RECD No Hold ST 4/6/00 MSTA710 Post/Beam Structural 4/21/00 RB PASS No Hold • RB 4/21/00 MSTA711 Post/Beam Mechanical 4/21/00 RB PASS No Hold RB 4/21/00 MSTA752 Rain drain lnsp 4/27/00 MRS FAIL No Hold AKJ 4/27/00 not ready MSTA752 Rain drain Insp 5/4/00 MRS PASS No Hold AKJ 5/4/00 MSTA704 Sewer Inspection 5/15/00 MRS PASS No Hold AKJ 5/15/00 MSTA752 Rain drain Insp 5/15/00 MRS PASS No Hold AKJ 5/15/00 MSTA761 Water Service Insp 5/15/00 MRS PASS No Hold AKJ 5/15/00 MSTA726 Shear Wall Insp 5/17/00 RB FAIL No Hold AKJ 5/17/00 see framing 5/17 MSTA720 Mechanical Insp 5/17/00 RB FAIL No Hold AKJ 5/17/00 see framing 5/17 Page 2 of 3 6/15/00 Activities for Case #: MST2000 -00087 7:07:02 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA726 Shear Wall Insp 5/17/00 RB PASS No Hold RB 5/18/00 2nd Inspection This Date. MSTA727 Exterior Sheathing Insp 5/17/00 RB PASS No Hold RB 5/18/00 2nd Inspection This Date. MSTA720 Mechanical lnsp 5/17/00 RB FAIL No Hold RB 5/18/00 2nd Inspection This Date. See Framing this date. MSTA725 Framing lnsp 5/17/00 RB FAIL No Hold RB 5/18/00 2nd Inspection This Date. 1. Studs missed w /in cripple walls of garage. 2. Support coat closet in garage. 3. Coat closet 2X4 construction- maintain R -21 insulation req'mts. • 4. Plumbing top -out req'mts not met. 5. Secure dryer vent in laundry room. 6. Insulate / Flame Spread fireplace cavity. 7. Over -bored /Notched floor -_ joists at family room and Kitchen - fix needed. 8. Hanger missed - above garage opening. 9. Soffit ductwork in garage. 10. Remove debris in crawl space. MSTA725 Framing Insp 5/18/00 RDP PASS No Hold AKJ 5/18/00 repair method a) run 2x4 on both sides of joist where is penetrating ok at insul b) run 2x4 top and bottom on 2" cut on one side MSTA740 Insulation lnsp 5/18/00 RDP PASS No Hold AKJ 5/18/00 MSTA720 Mechanical Insp 5/18/00 RDP PASS No Hold AKJ 5/18/00 Page 3 of 3