Loading...
Plans 1 Illi;4' , >z - EA.:1Z yAR-12) -4--- 2 CITY I F TIGARD - SITE PLAN REVIEW. „,., r. BUILDING PE MIT NO.: 0 .ag a 'M� S 3 t\-.1 E \V I•c�K PLANNING DI ISION: C a ^ 'a � �.. K Required Setba ks: (;il Approved ❑ Not Approved Side: $ Street Side: Front. . b Garage: -. Rear: / .S r • Visual CIearan. e: 1;21 Approved ❑ Not Approved t=xl / / / I ST Fe-c:: :'sax mum E tttl ling Height ...50 feet / / / 7 o .5T ! bU. 'service P ovider Letter Required: Yes ❑ N. / ' / ' / Reeeiv d / i ! / "DT'A 1 Imo'.. 5 Date: '74 Q i l l E NGI. EERIN DEPARTMENT: , / p % ❑ Approve Actual Slope: Approved ❑ Not Approver � ,' Plan: ❑ A ❑ Not Approved / ��' / / f Site , ) /� /` l" Date: �' � f � �� Notes: lo' - o" H outs E_ s tDE yARD CITY 0 TIGARD - SITE PLAN REVIEW BUILDING PERMIT NO: • Street Trees: ❑Approved ❑Not Approved SITE FL/N.1\1 Protected Trees: ❑ Approved ❑ Not A tpproved )4.4 um I'- o" By: Date` Notes: 2E.1=1_ACE LX 13T 11\I G ID 1-- C. i-<, 1 2 I G 2 S \u 13 I S T A. / E. ICJ LA E . yxy Pc>5T Fog WAiZD2p.1 L / HAN.' bR/ 1L 1 11 (TyR) [ 10 -0 ..c TJ'- 6 3'- o' _?,' -6 1 .4 �x ISr LO�v�R _ 17)c__.1-< I _ � yX IZCiEAM oN LIx Po6T C fit- — — — — — — — -le 1 1 1 r2 -o _O 2 _ 3' - 9 " 3' - 9 11 y' -6' n 1 - r- i bN� } 1 0 00, iii �� 0-11) r � - , (Yr� (3 6 STRINGERS I I A ._ __ -. E.xiST 1..oa R EX1 S Hot-,ISE / FL—A- \ ✓I E\\. OF TIGARD App roved ... ... ....um....... I 1.1- Conditionally Approved.—........... [ ] See Letter to: Follow...........—.... [ ] Attached.......... Permit Number.: ' CAP-il - CO .. — Ad. ,�..- :121 _ 2—all ? " _ Byy: Date: `9 l! OFFICE COPY r r - G1.,In.2DRA-.1 L. PER - r Y i I c..A. L CD - - I •L5 I I l 1 I VKEAID5 ". 1 1 �� �� >L 1 H IZ 16 ER-6 A.,T -7 1 %,s EA --\\ i I - tr) I H/1.N 1 1Z".t � PEK `r TYF'I c-A >EGK t'�NT�I L5 • I 2.) 2x1.2 r3E/■f`l l I I X l s _ = o y \l H Po 5 - r ---v- 4__. 2x6 . c 17--c)66 - BR • 5 Hsi PM .= sd ct 6 Z , 1°o6T 13A6E b EXIST pEcK- - 'NN T I I 0 b 1 I Lt - I - tv 12 *K12 - CONIC � I _1 a - - COIJG I '1 FOOT - 11.1 C� 1 - -- pO r I N 4 • 4 31 I I I _ L _ = I- -- _ L - - - -17 EL EVA1 - Io KJ . i 1 /z"_11 -QII • Typical Deck Details YOU CAN USE TO BUILD YOUR DECK (Valid for 2008, check for annual updates) n6,-,r,0 -- ' ` te r 7"' 11 \ \:,...,,,,,,,,,,,, ,,e',---4 / y i3 A:44 qq jr,,,,, 01 , _.,,,,,,.... ski I 3 u • � « �..+"" w?` � ...w ?8 I S$ { j Introduction 2 Lateral Support of Decks 13 Obtaining Permits 2 Joist Hangers 14 General Notes 2 Rim Joist Requirements 14 Getting Started 4 Built -up Beam Requirements 14 Beam, Joist, and Footing Sizes 4 Post -to -Beam Requirements 15 Post Sizes 8 Footings 15 Ledger Attachment Requirements 8 Guardrail Requirements 16 Prohibited Ledger Attachments 10 Stair Requirements 18 Ledger Board Fasteners 11 Stair Handrail Requirements 19 Freestanding Decks 12 Framing at Chimney or Bay Window..20 Name: 1`-) ft•■Z R.r•)P "5 Permit No: Address: I' .� 1 \J.E The use of this typical deck detail package in lieu of submitted drawings applies to single span, one level, single- family residential decks only. Decks must be constructed in strict conformance with the details contained herein. If a permit is required, a copy of this deck detail package must be on the job site and available to the inspector during the inspection process. This guide is intended to help provide typical information needed for constructing a deck; however, you will need to have at least some understanding of typical construction practices in order to complete the project. Typical Deck Details revised 2/08 Page 1 of 27 „fir INTRODUCTION These plans and details are provided to assist you in your deck construction, for obtaining a building permit (when required), or simply to aid you in constructing a deck that does not require a permit. Before proceeding, always check with your local jurisdiction for land use, zoning, or other regulations that may affect your project. When Do I Need A Permit For A Deck? A building permit is required for all decks that are 30 inches or more above grade. A building permit is not required for decks that are less than 30 inches above the ground and not less than 3 feet from a property line. How Do I Use The Plans To Get A Permit? if you need a building permit for your deck, you will need to submit plans of sufficient detail to your local building department to indicate what you want to build. If you are not sure how to draw plans, these plans can be submitted to your local building department for the permit. You will, however, be required to follow the plans and details as provided without any deviation. One thing that will be needed is a site plan that shows an outline of your property (property lines), the house, and outline of where you will be locating the deck and how it will appear. Be sure to indicate any additional existing accessory buildings or structures (shed, pool, retaining walls, etc.). The site plans will need to be drawn to an acceptable scale (you may need to contact your local building department for this), but usually a scale of 118 or 114 of an inch equal to one foot or similar is acceptable. Fill out a building permit application, and submit these plans (along with your site plan). After the plans are reviewed and approved, a permit to construct your deck will be issued (some jurisdictions may even be able to review and approve your plans at the counter, so you can leave with a permit the same day). Consult your local city /county jurisdiction for the number of sets of plans required. For information on contacting your local building departments, visit www.BCD.Oregon.gov, and click on Jurisdictions. How Big Do The Footings, Beams, And Joists Need To Be? The detail in these plans will help you determine how big the footings, beams, joists, posts, and ledgers need to be. Much of it depends on the size of the deck, what size beams and joists you want to use, and how far apart you want to place the beams, posts, and footings. General Notes 1. All lumber shall be grade #2 Douglas -Fir, Hem -Fir, or better and shall be pressure treated (to resist insect and dry rot) in accordance with American Wood- Preservers' Association Standards (Category). Decking material of redwood or cedar does not require pressure treatment as it has a natural resistance to decay. The pressure - treatment category identified below will be identified on the lumber. The level of treatment depends on the use as follows: a. Decking material, railings, joists, and beams must be treated to a Category UC3B. b. Posts and other woods located on, in, or in contact with the ground must be a Category UC4B. c. Any wood less than six inches above the ground or in contact with concrete must be a Category UC4A. Typical Deck Details revised 2/08 Page 2 of 27 It 2. The level of preservative treatment is noted on the tags fixed to the ends of the wood members. Remember, any time you make a cut, treat the cut end of the wood with a paint -on preservative. Cut ends expose the inner untreated wood to potential moisture and insect damage. 3. All nails shall be "common" or "box" galvanized. It is recommended that "common" nails be used. They have a thicker shank and are stronger than "box" nails. 4. New pressure treatment methods use chemicals that will prematurely corrode standard fasteners, hardware, and flashing when in contact with pressure treated lumber; and as a result, fastener and hardware requirements have changed. Note the following: a. All screws and nails shall be hot - dipped galvanized or stainless steel. b. All hardware (joist hangers, cast -in -place post anchors, etc.) shall be galvanized with 1.85 oz /sf of zinc (0 -185 coating) or shall be stainless steel. Look for products such as "Zmax" from Simpson Strong -Tie or "Triple Zinc" from USP. 5. Decks constructed according to this handout are not designed to support spas or hot tubs. Installation of spas or hot tubs will require additional structural supports. 6. Decks shall not be attached to house overhangs, bay windows, brick veneers, or chimneys. 7. Deck designs that deviate from the conditions of this handout will require a specific plan submission and may require engineering. 8. Inspections: a. A footing, framing, and a final inspection are required on all decks. b. Footing inspections are required PRIOR to the placement of concrete. c. Framing and final inspections may be combined if all portions of the deck framing and mechanical attachments are at least four feet above grade. d. It is the responsibility of the permit holder or the permit holder's representative to notify the city /county who issued the permit when stages of construction are reached that require an inspection. For information on contacting your local building departments, visit www.BCD.Oregon.gov and click on "Jurisdictions." 9. All decking material shall be composed of 2x4, 2x6, or five quarter ( "5/4 ") boards. Attach decking to each joist with two 10d nails or two #8 screws. Decking may be placed from an angle perpendicular to the joists to an angle of 45 degrees to the joists. Decking must have a span length such that each board bears on a minimum of two joists. 10. Plastic or composite decking products may be used as a substitute for conventional wood decking, but installation and span lengths of the substituted material must be in strict conformance with the product listing and the manufacturer's installation instructions. Copies of the manufacturer's installation instructions must be submitted with this handout and permit application. Typical Deck Details revised 2/08 Page 3 of 27 I 11. The sizing for footings, posts, beams, and joists are only to be used in areas (counties) that have an elevation at or below that indicated in Table 1. Areas above those indicated in Table 1 need to consult their local jurisdictions for snow loading to determine if the area is subject to snow loads in excess of 40 pounds per square foot. If the snow loads exceed 40 pounds per square foot, this document cannot be used. 12. Footings for decks constructed according to this handout shall not be placed on ground with a slope greater than 2 horizontal for every 1 vertical. 13. Decks that are greater than six feet in width and attached to the house with doors, windows or openings below must check the to verify the existing headers over those openings can support the additional load added by the deck. Check with your local jurisdiction for the Oregon Residential Code table to verify. Table 1 Snow Load (Maximum Elevation for Counties with a Snow Load of 40 psf or Less) Maximum elevation 750 feet: Benton, Clatsop, Columbia, Coos, Curry, Lincoln, Polk, Tillamook, Washington, Yamhill Maximum elevation 900 feet: Clackamas, Marion, Lane, Multnomah Maximum elevation 1,000 feet: Linn Maximum elevation 2,000 feet: Douglas, Josephine, Sherman, Wasco Maximum elevation 3,000 feet: Baker, Gilliam, Morrow, Umatilla, Union, Wallowa Maximum elevation 4,000 feet: Crook, Deschutes, Grant, Harney, Jefferson, Klamath, Lake, Malheur, Wheeler Cannot be used in Hood River County (minimum 50 psf snow load) Getting Started To effectively use the information contained in this document, you will need to do the following: 1. Determine if your deck requires a permit. Note: even if a permit is not required, zoning regulations (setbacks) and public utility easement restrictions are still applicable. Before proceeding, always check with your local jurisdiction for land use, zoning, or other regulations that may affect your project. 2. Determine where your property lines are located and what setbacks your jurisdiction requires from the property line to the edge of the deck. 3. Determine if you have any public easements on your property and whether or not the deck can be constructed over the easement, if applicable (in most cases, you cannot build over a public easement). Typical Deck Details revised 2/08 Page 4 of 27 4. Determine how big and what configuration you want your deck. Note: The drawings contained in this document may indicate square or rectangular configurations; however, configurations can be diamond, trapezoidal, or other shapes as long as the longest spans are used to determine beam, joist, and footing sizes. The deck can have up to a two -foot maximum joist and /or beam overhang. See Figures 1, 2, and 3. Beams must be support on each end by a post and cannot be supported with beam hangers off the house. (Beams are identified as item "A ", posts as item "B ", joists as item "C," and footings as item "D. ") It is recommended that you first determine the joist span "C," and then note what beam and footing sizes you will need. BEAM, JOIST, AND FOOTING SIZES The span of a joist is measured from the centerline of bearing at one end of the joist to the centerline of bearing at the other and does not include overhangs. Maximum joist span lengths are noted in Tables 2 and 3. See Figures 1 and 2 for joist span types. OPTIONAL OVERHANG BLOCKING ., • fk L._ 2' -4' JOIST SPAN MAX MIN SPAN mm 6-0" WITH OVERHANG Figure 1 - Joist Span — Deck Attached At House OPTIONAL OVERHANG r . _ BLOCKING =i ` - e-< , a.�. � � 1 ..._., , .�<..,_R • j r k :c 1 { l I_. JOIST SPAN I Z-0" MAX M N SPAN 5' OVERHANd Figure 2 - Joist Span - Free - Standing Deck Typical Deck Details revised 2/08 Page 5 of 27 • O ='4A.L OV`t t N x t �1 sP tii AT> aNTERM POST LLCATI NM ONLY ., i,_ - �•_�— ...'. —`— _� ._„n., — „s�...,.. , -:i.. e gg 2'41 BEAM 8PPP4 !K AM SPAN Figure 3 - Beam Span Types 5. Tables 2 and' 3 provide you with the information to determine how big the footings, beams, and joists need to be. The size will depend on how big the deck will be and how many footings and posts are going to be used; how far the beam(s) will span from post -to -post (or ledger); and how far the joist will span from beam -to -beam. To start with, contact your local jurisdiction to determine what the assumed soil bearing value is for your area. This document has footing details for soils that can support between 1,000 to 1,500 pounds per square foot (psf) (See Table 2) and soils that can support over 1,500 pounds per square foot (psf) (See Table 3). If you have soil bearing of less that 1,000 psf, you will need to consult with your local jurisdiction. Note: The footing details are based on native soil and not soil that has been • deposited on your property (fill) in depths greater than 12 inches. The footing details require a footing that is a minimum of 18 inches in height so the bottom can be located a minimum of 12 inches below the finished grade and extend six inches above the finished grade. If you have fill material that is greater than 12 inches, your footing will need to extend through the fill to native soil. The footing will need to extend below the finished grade due to the frost depth for your county. See Table 4 to determine this depth. Footings for freestanding decks (those not attached to the house) are not required to be placed below the frost line. Footings for freestanding decks may reduce the footing thickness to a minimum of eight inches. • Typical Deck Details revised 2/08 Page 6 of 27 • TABLE 2 DECKS ON SOIL WITH A 1000 PSF TO 1500 PSF BEARING CAPACITY (Note: All footings are to be placed a minimum of 12 inches below the surface of the finished grade and cannot be placed on fill.) 2x6 joists cannot be used when a guardrail is required. 1.) If you And 2.) you Then 3.) And 4.) the And 5.) they And 6.) the have a beam have posts you can minimum can be footings "D" "A" that is: "B" only span size joist spaced a supporting the supporting the joists you can use maximum posts will need the beam "C ": is: of: to be a spaced: minimum of: 14 "x14 "x 18" or 4x6 or (2) 2x6 6' -0" apart 6' -0" 2x6 24" apart 16" diameter x 18" 18x18 "x 18" or 4x8 or (2) 2x8 8' -6" apart 6' -0" 2x6 24" apart 20" diameter x 18" 20 "x20 "x18" or 4x10 or (2) 10' -6" apart 6' -0" 2x6 24" apart 23" diameter x 2x12 18" 22 "x22 "x18" or 4x12 12' -6" apart 6' -0" 2x6 24" apart 25" diameter x 18" 18x18 "x 18" or 4x6 or (2) 2x8 6' -0" apart 8'-0" 2x6 or 16" a or 20" diameter x 2x8 24" apart 18" (2 ) 2x6 or 16" apart or 20 °x20 "x18" or 4x8 or 8' -0 apart 8' -0" 23" diameter x 2x10 2x8 24" apart 18" 22 "x22 "x18" or 4x10 or (2) g� -6" apart 8 %0 2x6 or 16" apart or 25" diameter x 2x12 2x8 24" apart 18" 2x6 or 16" apart or 22' "x18" or 4x12 11 apart 8' -0" 2x8 24" apart 25 diameter x 18" 2x8 or 16" apart or 18',x18 "x 18" or 4x6 or (2) 2x8 5' -6" apart 10' -0" 2x10 24" apart 20" diameter x 18" 20 "x20 "x18" or 4x8 or (2) 7' -6" apart 10' -0" 2x8 or 16" a or 23" diameter x 2x10 2x10 24" apart 18" 22 "x22 "x18" or 4x10 or (2) g� -0" apart 10'-0" 2x8 or 16" apart or 25" diameter x 2x12 2x10 24" apart 18" 2x8 or 16" apart or 24 "x24 "x18" or 4x12 10' -6" apart 10' -0" 2x10 24" apart 27 d x 18" Typical Deck Details revised 2/08 Page 7 of 27 • 1.) If you And 2.) you Then 3.) And 4.) the And 5.) they And 6.) the have a beam have posts you can minimum can be footings "D" "A" that is: "B" only span size joist spaced a supporting the supporting the joists you can use maximum posts will need the beam "C ": is: of: to be a spaced: J I minimum of: 18 "x18 "x18" or 4x6 or (2) 2x8 5' -0" 12'-0" 2x10 2x12 or 16 24 " ' ' apart or 20 „ diameter x 18” 20 "x20 "x18" or 4x8 or (2) 6' -6" 12' -0" 2x10 or 16" apart or 23" diameter x 2x10 2x12 24" apart 18„ 4x10 or (2) 2x10 or 16" apart or 22;x22 "x18" or 2x12 8'-6" 12'-0" 2x12 24 apart 25" diameter x 18" 24 "x24 "x18" or 2x10 or 16" apart or 4x12 10' -0" 12' -0" 2x12 24" apart 27" diameter x 18" 18 "x 18 "x 18" or 4x6 or (2) 2x8 4' -6" 16' -0" 2x12 16" apart 20" diameter x 18" 22 "x22 "x18" or 4x8 or (2) 6' -0" 16' -0" 2X12 16" apart 25" diameter x 2x10 18" 4x10 or (2) 24 "x24 "x18" or 2x12 7' -6" 16' -0" 2X12 16" apart 27" diameter x 18" 26 "x26 "x18" or 4x12 9' -0" 16' -0" 2x12 16" apart 30" diameter x 18" Typical Deck Details revised 2/08 Page 8 of 27 TABLE 3 DECKS ON SOIL WITH A 1500 PSF OR GREATER BEARING CAPACITY (Note: All footings are to be placed minimum of 12 inches below the surface of the finished grade and cannot be placed on fill.) 2x6 joists cannot be used when a guardrail is required. 1.) If you And 2.) you Then 3.) And 4.) the And 5.) they And 6.) the have a beam have posts you can minimum can be footings "D" "A that is: "B" only span size joist spaced a supporting the supporting the joists you can use maximum posts will need the beam "C ": is: of: to be a spaced: minimum of: 12 "x 12 "x 18" or 4x6 or (2) 2x6 6' -0" apart 6' -0" 2x6 24" apart 14" diameter x 18" 15x15 "x 18" or 4x8 or (2) 2x8 8' -6" apart 6' -0" 2x6 24" apart 17" diameter x 18" 16 "x16 "x18" or 4x10 or (2) 10' -6" apart 6' -0" 2x6 24" apart 18" diameter x 2x12 18" 18 "x18 "x18" or 4x12 12' -6" apart 6' -0" 2x6 24" apart 20" diameter x 18" 14x14 "x 18" or 2x6 or 16" apart or 4x6 or (2) 2x8 6' -0" apart 8' -0" 2x8 24" apart 16" diameter x 18" 16 "x16 "x18" or 4x8 or (2) 2x6 or 16" apart or „ 2x10 8' -0" apart 8' -0" 2x8 24" apart 18 diameter x 18" 18 "x 18 "x 18" or 4x10 or (2) g' -6" apart 8' -0" 2x6 or 16" apart or 20" diameter x 2x12 2x8 24" apart 18„ 18 "x18 "x18" or 2x6 or 16" apart or 4x12 11' -0" apart 8' -0" 2x8 24" apart 20" diameter x 18" 14 "x 14 "x 18" or 2x8 or 16" apart or 4x6 or (2) 2x8 5' -6" apart 10' -0" 2x10 24" apart 16" diameter x 18" 16 "x16 "x18" or 4x8 or (2) 7' -6" apart 10' -0" 2x8 or 16" apart or 18" diameter x 2x10 2x10 24" apart 18" 18 "x18 "x18" or 4x10 or (2) „ 2x8 or 16” apart or 2x12 9'-0" apart 10'-0" 2x10 24" apart 20" diameter x 18" 20 "x20 "x18" or 4x12 10' -6" apart 10' -0" 2x8 or 16" apart or 23" diameter x 2x10 24" apart 18„ Typical Deck Details revised 2/08 Page 9 of 27 • 1.) If you And 2.) you Then 3.) And 4.) the And 5.) they And 6.) the have a beam have posts you can minimum can be footings "D" "A" that is: "B" only span size joist spaced a supporting the supporting the joists you can use maximum posts will need the beam "C ": is: of: to be a spaced: minimum of: 14 "x14 "x18" or 4x6 or (2) 2x8 5' -0" 12' -0" 2x10 or 16" apart or 16" diameter x 2x12 24" apart 18" 4x8 or (2) 2x10 or 16" apart or 16;,x16 "x18" or 2x10 6' -6" 12' -0" 2x12 24" apart 18 diameter x 18" 4x10 or (2) 2x10 or 16" apart or 18"x18"x18" or 2x12 8' -6" 12' -0" 2x12 24" apart 20" diameter x 18" 20 "x20 "x18" or 4x12 10' -0" 12 ° -0" 2x10 or 16" apart or 22" diameter x 2x12 24" apart 18" 15 "x15 "x18" or 4x6 or (2) 2x8 4' -6" 16' -0" 2x12 16" apart 17" diameter x 18" 4x8 or (2) 18 "x18 "x18" or 2x10 6' -0 16' -0 " 2X12 16" apart 20" diameter x 18" 4x10 or (2) 20 "x20 "x18" or 7' -6 16' -0 " 2X12 16" apart 23" diameter x 2x12 18" 22 "x22 "x18" or 4x12 9' -0" 16' -0" 2x12 16" apart 25" diameter x 18" Table 4 Frost Depth Counties with a frost depth of 12 Benton, Clackamas, Clatsop, Columbia, Coos, inches: Curry, Lane, Lincoln, Linn, Marion, Polk, Tillamook, Washington, Yamhill Counties with a frost depth of 18 Crook, Deschutes, Douglas, Jackson, Jefferson, inches: Josephine, Multnomah Counties with a frost depth of 24 Baker, Gilliam, Grant, Harney, Hood River, inches: Klamath, Lake, Malheur, Morrow, Sherman, Umatilla, Union, Wallowa, Wasco, Wheeler Typical Deck Details revised 2/08 Page 10 of 27 • 6. After determining the soil bearing capacity, frost depth, sizes for the footings, posts, beams, and joist from the table, mark the information in the space provided below: a. Soil Bearing Value: I , c3o psf. b. Frost Depth: , 1 ;' inches. c. Footing Size: I ±J " x i x 1 , spaced V c apart. d. Post Size: '-I x S , spaced i v ' apart. e. Beam Size: (z) x , spaced ' apart. f. Joist Size: Q x 3 , spaced I ri apart. 7. Determine if you will be connecting to a band board (rim joist), see Figure 5; a concrete wall, see Figure 6; or a sill plate, see Figure 7. Note: This document cannot be used with masonry walls. 8. See Figures 14 to 36 for bracing, connection, built -up beam, footing, guardrail, handrail and stairway details. POST SIZES Post sizes are 4x4 minimum for decks six feet or less above the ground and 4x6 for decks over six feet above the ground. Decks with posts over ten feet above the ground cannot be used and require an engineered design. Use a minimum 4x6 post under all beam splices. LEDGER ATTACHMENT REQUIREMENTS General: There are several methods for attaching a ledger board to the house. How it is attached depends on how the house is constructed and where the ledger will be attached. Ledger board attachments to the existing exterior wall shall be constructed in accordance with Figures 5 through 7. When attachments are made to the existing house band board, it shall be capable of supporting the new deck. If this cannot be verified or conditions at the existing house differ from the details herein, then a free- standing deck is required (See section on Free - Standing Decks.). You must verify the existing conditions in the field prior to applying for a building permit. Compliance with all the requirements herein is critical to ensure the structural stability of your deck. Siding and Flashing: Siding or the exterior finish system must be removed prior to the installation of the ledger board. Flashing is required at any ledger board connection to a wall of wood - framed construction and shall be composed of copper (attached using copper nails), stainless steel, UV- resistant plastic, or galvanized steel coated with 1.85 oz/sf of zinc (G -185 coating). Manufactured Wood Joist: The term "MWJ" denotes manufactured 6r /. wood "I" joists. See Figure 4. Examples of manufactured wood joists are TJI, GPI, and LPI. Older homes constructed with MWJs may only include a plywood band board, while some newer homes may have 1' - inch manufactured wood rim joists. In these cases, a freestanding deck �i or a full plan submission is required. 1 Figure 4: MWJ Profile 2/08 Page 11 of 27 • EXTERIOR SHEATHING CONT FLASHING W/DRIP EDGE BEHIND BUILDING PAPER OR WATERPROOF EXISTING WALL II MEMBRANE EXISTING 2X DECKING OVER RIM (BAND) DECK JOIST MEI WI! 2X FLR JOIST I 2X LEDGER EXISTING WALL , (2) 318" LAG SCREWS OR FRAMING OR (2) 414 WOOD SCREWS OR CONCRETE WALL (1) SIMPSON SOS SCREW (SHOWN DASHED) ; OR EQUAL eg SPACING "S" Figure 5 — Attachment of Ledger Board to Band Board with Lag or Wood Screws (See Figure 11 for Spacing "S"). • 8RACING "S" , JOIST SPAN (2) 318' DIA LAG SCREWS (2)414 WOOD SCREWS SIMPSON SOS 114 X 3 1/2" 0 < SPAN s, 8' - r' — 2`4 10 16 16" 8' SPAN 10' 5* 8" 16" • 10"‹ SPAN:414' 4" 8" 12" 14"< SPAN 416' 3* 5" 9' Typical Deck Details revised 2/08 Page 12 of 27 .. • , EXTERIOR CONT FLASHING W/ DRIP SHEATHING EDGE BEHIND BUILDING PAPER OR WATERPROOF EXISTING WALL MEMBRANE DECKING OVER EXISTING 2X — 1 DECK JOIST RIM (BAND) , ' I, . ii . L i w j ... 41 . a . iftri.- i r 1 2X FLR I 2X LEDGER W/ 1/2" DIA BOLTS JOIST OR MWJ I STAGGERED AT SPACING "S" LOCATE FIRST BOLT 2" FROM EXISTING WALL END OF LEDGER. FRAMING OR CONCRETE WALL i (SHOWN DASHED) Figure 6 — Attachment of Ledger Board to Band Board with Bolts. (See Figure 11 for Spacing "S"). JOIST SPAN SPACING "S" 0 < SPAN .5 8i 10" 8' < SPAN 5 10' 8" 10'< SPAN s14' 6" 14`< SPAN 5.16' 5,, SEE FIGURE 11 FOR DETAIL Typical Deck Details revised 2/08 Page 13 of 27 CONCRETE WALL DECKING OVER DECK JOIST 11"="41111-11111110101 1 101. if 2X LEDGER WI 112" DIA EXPANSION ANCHORS STAGGERED AT SPACING "S" WITH MINIMUM 21/? EMBEDMENT, Figure 7 — Attachment of Ledger Board to Concrete Wall. (See Figure 11 for Spacing "S"). JOIST SPAN SP S" 0 < SPAN „<.. 8' 18" < SPAN s 10'< SPAN 414 10" 14'< SPAN 1B 5" SEE FIGURE 11 FOR DETAIL Typical Deck Details revised 2/08 Page 14 of 27 • PROHIBITED LEDGER ATTACHMENTS Attachments to the ends of premanufactured open web joists, to brick veneers, and to house overhang /bay windows are strictly prohibited; see Figure 8 through Figure 10. In such cases the decks shall be free - standing. See section on Free - Standing Decks. hi . �,r; �rela tlaor isusses — um IIII , - 0, - 0 M P de ck f deck 1• " : lI / a jc� [� � i� gist Il II! . ` � � ' �� t i.r�111� � I� 00.-=-44 pr � bick or III �� ,, ve neer mason II _ chimney Figure 8: No Attachment Figure 9: No Attachment Figure 10: No Attachment To Open Web Trusses To Brick Veneer To House Overhang LEDGER BOARD FASTENERS All fastener types shall be spaced per the tables provided with Figures 5 through 7 and installed per Figure 11. All fasteners shall be installed with washers and must be thoroughly tightened. Adequacy of connections shall be verified by the building inspector. If a ladder is required to access the ledger board fro inspection, one must be provided by the property owner, permit holder, or their representative. WHERE SIMPSON SOS SCREWS 1 112" ARE USED, STAGGER SCREWS / " TOP AND BOTTOM 0 a o \ .- -C' EQ..., o �c ` PLATE BEYOND EC) _..4 9 0 0 C / I SPACING "S" Figure 11 - Ledger Board Fastener Spacing and Clearances Thru - bolts: Thru -bolts shall have a minimum diameter of 1 /2". Lead (pilot) holes for thru -bolts shall be 17 /32" to 9 /16" in diameter. Thru -bolts must be equipped with washers at the bolt head as well as the nut. Thru -bolts are those where a hole is drilled all the way through the wood members and a nut and washer are attached to complete the connection. Typical Deck Details revised 2/08 Page 15 of 27 Expansion (Wedge) Anchors: Use expansion anchors when attaching a ledger board to a concrete wall as shown in Figure 7. Bolt diameters of the anchors shall be a minimum of IA"; in some cases, this may require an anchor size of 5 /8". Minimum embedment length shall be 2'/2". Expansion anchors must have washers. IMPORTANT NOTE: Expansion anchors must be installed as required by the manufacturer's instructions. This may include cleaning the holes drilled in the concrete to ensure they are free of dirt, debris, and moisture. Improper installation of the anchors can result in catastrophic failure and collapse of the deck. Copies of the manufacturer's installation instructions must be submitted with this handout and permit application. Lag Screws: Lag screws shall have a minimum diameter of and and shall be hot - dipped galvanized or stainless steel. Lag screws may be used only when the field conditions match those shown in Figure 12. You must verify the existing conditions in the field prior to applying for a building permit and installing lag screws. Compliance with all the requirements herein is critical to ensure the structural stability of your deck. See Figure 12 for lag screw length and shank requirements. All lag screws shall be installed with washers. Lag screws are those where a pilot hole is drilled into the wood members that are to be connected together and the lag is screwed into the hole, a washer is required on the lag head, but no nut and washer is needed on the screw end. lag screws must be not dipped galvanized of 111101K stainless steel only ' strew must penetrate beyond band bcardirim 1-1.Z shank length rrtust extend t t ugh List a Mu 1411uM of tl2° (no threads) existing band board /elm joist Figure 12 - Lag Screw Requirements Lag Screw Installation Requirements: Each lag screw shall have lead (pilot) holes drilled as follows: 1) drill a 3 /8" diameter hole in the ledger board, 2) drill a /16" diameter hole into the solid connection material of the existing house. DO NOT DRILL A 3 /8" DIAMETER HOLE INTO THE SOLID CONNECTION MATERIAL. The threaded portion of the lag screw shall be inserted into the lead hole by turning. DO NOT DRIVE WITH A HAMMER. Use soap or a wood - compatible lubricant as required to help facilitate tightening. Each lag screw shall be thoroughly tightened. Typical Deck Details revised 2/08 Page 16 of 27 FREESTANDING DECKS RIM JOK7 --1 Decks that are free- 1 standing do not utilize the 111111 exterior wall of the existing house to support vertical } ., '� or lateral loads. Support at ` < or near the house is , .: '-" ? ` . � .; ' provided by an additional. ,,44 beam and posts. See .a.3 I b .= Figure 13. Beam size is ° , ›, - -K '_ y `� ' ~ ~ GRAZE ! determined by Table 2 or i 1 i Table 3. i '` L ` -- Figure 13 - Free - Standing Deck LATERAL SUPPORT OF DECKS Decks greater than 30- inches above grade shall resist lateral loading and movement by the following methods: ILL I r i F 41fire'.rA. _ _.� �-1.`11 2� THROUGH CROSS —` '" 3 -,; . -. T nr EACH BRACE r ` \ ',. I g I ///// \ I \ � gpp ° V «,...,. , gg g — .. f '' 2 ; -. SOLID BLOCK AT INTERSECTION OF WOOD BRACES W TH (1) 3i3` DIA THROUGH BOLT (TYPICAL) Figure 14 DIAGONAL BRACING REQUIREMENTS Diagonal Cross Bracing: Provide diagonal cross bracing as shown in Figure 14. Bracing shall be located between posts parallel to beams and bolted by a minimum 3 /8" ! diameter through -bolt at each end to the posts as shown. Diagonal bracing shall also be located perpendicular to beams, and in such cases, bracing shall be bolted to the post and joist above the post location. If the deck is free - standing, diagonal bracing must be provided on all the posts and in both directions. Bracing shown in figure 14 is required in every bay between posts for decks with joist spans up to 8 feet. Decks with joist spans greater than 8 feet require an engineered design. Typical Deck Details revised 2/08 Page 17 of 27 ! • Attachment to House: Lateral support is provided for one -half of the deck by the attachment of the deck rim joist to the existing house as shown in Figure 15 (the beams and posts furthest from the house still require the diagonal bracing as shown in Figure 14). The existing exterior wall must have sheathing consisting of structural wood panels with a minimum thickness of 3/8 ", and the fasteners shall attach to an existing band board or wall stud. The deck rim joist may also attach to a concrete wall, but not to a brick veneer. You must verify this condition in the field prior to utilizing this method. Fasteners shall be 16" on center and must penetrate existing wall studs. See also the provisions noted on page 11. Flashing over the rim joist is required and must be installed in accordance with the flashing provisions noted on page 11. REMOVE SIDING AT RIM JOIST LOCATION T PRIOR TO INSTALLATION EXTERIOR SHEATHING . MIN. THICKNESS - 318" CONTINUOUS TIIJUt)U FLASHING WITH DRIP EDGE EXISTING WALL --.e_ i - FASTENERS a '16" O.C. ,. ;. `Sij +;, 1" MIN. SEE rAsLF 5 1" MIN.. Figure 15 - Attachment to House Lateral Support Table 5 Attachment to House Joist span Required Fasteners to each Stud or 16 inches o.c. max. 0'< span < 8' (3) #10 x 4 wood screws 8'< span < 10' (4) #10 x 4 wood screws 10'< span < 14' (6) #10 x 4 wood screws 14'< span < 16' (6) #10 x 4 wood screws JOIST HANGERS Joist hangers, as shown in Figure 16, shall have a minimum capacity of 1,000 pounds. Joist hangers used shall be manufactured for their intended lumber size. Joist hangers shall be galvanized with 1.85 oz/sf of zinc (G -185 coating) or shall be stainless steel. Figure 16 - Typical Joist Hangers Typical Deck Details revised 2/08 Page 18 of 27 Joist -to -Beam Connection: Each joist shall . 11 f natkd ma $dt�e f y tre in5W1lad e Ch a "' � "' "� be attached to the beam as shown in Figure lieu 61 toe -naffs • I f a 17. Mechanical fasteners shall be galvanized UMW \' with 1.85 oz/sf of zinc (G -185 coating) or shall be stainless steel. Figure 17 - Joist -to -Beam Detail Rim Joist Requirements: Attach a - - --- s cua DECKI , G TO continuous rim joist to Tap OF RIM ,O \ "WITH x 3" f Cil the ends of joists as ,,300 sew,,, ac,. Jam \ shown in Figure 18..., Please note that the rim are required at ends of joists associated with free - �r� " �� , RIM JOIST TO standing decks. END of EA,Cil JOIST Minimum rim joist WITH 5. 410x T Ml dimensions shall be 1 'A'OCD SCREW'S JOI ST equal to the dimensions of the joist. Figure 18 - Rim Joist Connection Built -Up Beam 10d nail or #1d 2-fasteners, each end Requirements: wood screw, typ_ Built -up beams shall be ° ' + • ' + assembled 9 9 ! I . . • v �,, in accordance with Figure 19. - . +► —•6 The nailing tarp.. tYP- pattern shall be Figure 19 - Built -Up Beam Detail staggered as shown. POST - TO - BEAM REQUIREMENTS The post -to -beam connection shall be made with premanufactured mechanical connectors. Mechanical connectors shall be galvanized with 1.85 oz/sf of zinc (G -185 coating) or shall be stainless steel as shown in Figure 20. Post -to -beam connections may also be accomplished using a minimum 4x6 post notched for a 4x beam as shown in Figure 21. All thru -bolts shall have washers at the bolt head and nut. Typical Deck Details revised 2/08 Page 19 of 27 • • 2" MIN. l__ I2I 2X MAIM . , ' _4.,. 2.112" DIR THRU ,, (2) 2X BEAM °'-' �;; - BOLTS AND f._ � WASHERS POST TO BE ,... �� 1112 (�}(N _ _ CONro r., 1 ,14 4 X �i MIN 4X6 MIN. ____, mot .., _� �.. NOTCH POST TO i 3m,. ACCOMODATE BEAM Figure 20 - Post -to -Beam Requirements Figure 21 - Post -to -Beam Requirements FOOTINGS See Table 2 or 3 for footing PRE size and footing thickness CAST - IN - PLACE and Figure 22 for post attachment requirements. All 6" MIN `, ' 4 4 / „, POST ANCHOR footings shall bear on solid fi ..A ground. Bearing conditions shall be verified in the field by i your local jurisdiction during the footing inspection, prior to 16" SQUARE OR placement of concrete. 18" DIA. ROUND Footings closer than 3' -0" to the existing exterior house Figure 22 - Typical Footing Detail wall must bear at the same elevation as the existing wall footing. Do not construct footings over utility lines or enclosed meters. Call 1- 800 - 332 -2344 before you dig. Premanufactured post anchors shall be galvanized with 1.85 oz/sf of zinc (G -185 coating) or shall be stainless steel. Post anchors shall be capable of supporting a minimum of 3,000 pounds. Where bracing is required by figure 14, the post anchors must be rated for horizontal (seismic) forces. Footings must extend below the frost depth for your area. See Table 4 for the frost depths in your county. Footings for freestanding decks (those not attached to the house) are not required to be placed below the frost line. Footings for freestanding decks may reduce the footing thickness to a minimum of eight inches. Note: Footings for decks constructed according to this handout shall not be placed on ground with a slope greater than 2 horizontal for every 1 vertical. Footings adjacent to the top of a retaining wall must be set -back from the top of the wall a distance equal to the height of the wall, or be placed below grade an amount equal to the height of the retaining wall. Typical Deck Details revised 2/08 Page 20 of 27 GUARDRAIL REQUIREMENTS Decks less than 30" above grade are not required to have a guardrail; however, if one is installed, you must follow these requirements. All decks and stairways over 30" above grade require guardrails. All guardrails shall be constructed in strict conformance with the figures herein; any deviations require a plan submission. 4 X 4 POST, TYP, 4' -0" MAX SPACING 2 X 2 PICKET, TYP. DO NOT NOTCH I / 2 X 6 OR 5/4 BOARD RAIL CAP t 2 D Fn 2X4ATTOP —___ OPENINGS SHALL NOT ATTACH PICKETS AT TOP AND BOTTOM WITH SEE GUARD POST ALLOW THE PASSAGE 2- #8 SCREWS OR 2- 8d ATTACHMENT DETAILS OF A 4" DIA SPHERE SPIRAL SHANK NAILS EACH. Figure 23 — Typical Guardrail Detail • Any prefabricated wood, plastic, or manufactured guardrail system purchased from a home center store, lumber company, or somewhere similar will also require a plan submission. The guardrail shall be designed to withstand a concentrated load of 200 pounds anywhere along its length, and the infill area is designed to withstand a load of 50 pounds on a square foot area. Guardrail Post Attachment: There are three options for guardrail attachment provided, you may choose one that suites your needs or provide a design for approval. Guardrail posts shall be spaced per Figure 23 and attached per Figures 24, 25 or 27 and 26, 29. Note: 2x8 minimum joists are required for Figures 24 and 25, and minimum 2x10 joists for Figure 27. Holdowns, tie plates, bolts, nuts and washers must be hot dipped galvanized with 1.85 oz/sf of zinc (G -185 coating) or shall be stainless steel. Look for products such as "Zmax" from Simpson Strong -Tie or "Triple Zinc" from USP. i Typical Deck Details revised 2/08 Page 21 of 27 • • • 4X4 POSTS (PICKETS SIMPSON HD2A HOLDOWN & RAIL,S NOT SHOWN WI (2) 5/8" DIA. GALV. FOR CLARITY) THROUGH BOLTS WI .7 DECKING WASHERS AT FAR SIDE (2) 5/8" DIA, GALV, THROUGH 1 1/2" Mu, .* BOLTS Wi WASHERS • 1 1/2' MIN. (3)1 ed NAILS AT EACH JOIST ___ 2 X 8 MIN, DECK JOISTS 2 X 8 RIM JOIST POST ON OUTSIDE Figure 24 - Guardrail Attachment Option 1 4X4 POSTS (PICKETS SIMPSON HD2A HOLDOWN & RAILS NOT SHOWN W/ (2) 5/8" DA. GALV, FOR CLARITY) THROUGH BOLTS W/ DECKING, . WASHERS AT FAR SIDE (2) 5/8" DIA, GALV. THROUGH 1,2n „F Boas wi WASHERS me,g6clie / 1 44.317 . (3) Il S v I S A A IN T LESS CH ST J E 0 E is L T - r 2 X 8 MIN. DECK JOISTS 2 X 8 Rim JOIST • RIM JOIST ON OUTSIDE Figure 25 - Guardrail Attachment Option 2 • Typical Deck Details revised 2/08 Page 22 of 27 • s• 4X4 POSTS (PICKETS SIMPSON HD2A HOLDOWN & RAILS NOT SHOWN WI (2) 5/8" DIA. GALV. . FOR CLARITY) — THROUGH BOLTS WI WASHERS AT FAR SIDE DECKING —\ (2) 5/8" DIA. GALV. THROUGH .// 801 TS WI WASHERS a vig ../ —i - 2 X 8 MIN. RIM JOIST • 2 X a MIN.—' —2X BLOCKING WI SIMPSON A34 DECK JOISTS FRAMING ANGLE AT EACH SIDE AT EACH END (4 TOTAL) POST SUPPORTED ON PARALLEL FRAMING Figure 26 — Guardrail Attachment Fraiming Parallel to Framing 2 X 6 TOP RAILING CONNECT TO POST W (2) #10 X 3" WOOD 2 X 2 PICKET @ 5 1/2" 0,C, MAX. SCREWS (MAY BE — Al (ACH PICKETS AT TOP AND FLAT OR VERTICAL) y BO r I OM W/(2) #8 WOOD SCREWS OR (2) ad SPIRAL 2, X 4 sarrom SHANK RAILING. CONNECT NAILS EACH, TO POST W;(2) I 4 X 4 POST #10 X 3" WOOD I 2-112" DIA. THROUGH SCREWS —V A - 1 r BOLTS W/ OVERSIZED MAX 1 WASHER_ (1 1/2" DIA. MIN.) Biome:EA 1 • 1" MIN, ,; 0 I_W_Ash \ 1 112' AMU ' - A . 6 A 1" MIN. ' 1 1141 — 2pr - \ L6 X 3 X 1/4 X 0'-9" \ -2 X 10 MIN. STEEL ANGLE W/(2) \ 3/4" DIA. THROUGH BOLTS W1(2) VERTICAL SHORT SLOTTED HOLES Figure 27 — Guardrail Attachment Option 3 Typical Deck Details revised 2/08 Page 23 of 27 • (2) 3/4" DIA. THROUGH BOLTS NM 4 X 4 POST 2 X 18 JOIST OR = 2 X 10 BLOCKING Wi SIMPSON A34 I A. FRAMING ANGLE AT EACH SIDE AT EACH END, (4 TOTAL) 2 X 10 RIM JOIST SECTION A-A Figure 28 — Guardrail Attachment Section for Option 3 2 X 8 TOP RAILING CONNECT TO POST W (2) #10 X 3°' WOOD 2 X 2 PICKET @ SCREWS ( RAILING MAY BE " 5 1/2 D.C. MAX. FLA1 OR VERTICAL) V\ I ATTACH PICKETS 2 X a E3OTTOM AT TOP AND BOTTOM —4. — RAILING. CONNECT --- _21 W1(2) #8 WOOD TO POST W1(2) ( ., 7 4:) SCREWS OR (2) 8d #10 X 3 WOOD I SPIRAL SHANK - DECKING SCREWS I NAILS EACH. \ 4 X4 POST DECK / . = FRAMING — SEE GUARD POST ATI ACHMENT DETAILS Figure 29 — Guardrail Railing and Picket Detail Typical Deck Details revised 2/08 Page 24 of 27 • STAIR REQUIREMENTS Stairs, stair stringers, and TREAD IATEta FROM N stair guardrail shall meet the NOT «4b`IAFF, G't t 7-11SER MAY BE CP F'@N. ONE ANOTIER 9Y BUT %MU. t2O ALLOW requirements shown in Figure MORE THAN 316` THE €o.ma OF '\ 4 DIA SPHERE 30 through Figure 36. All \, stringers shall be minimum �'�'' ' = 2x12. A level landing > - X RlS ;., j WIDTH - j minimum 3 feet by 3 feet is h1E7csNT SHALL N T € DtTA FROM ONE .. -,\ '�. RISERS!, t;t.G1 1_I? ?l f1f�i required at the top (usually ANOTHER 3YMORE ; this is the deck) and at the TttA^11T ....- if i,� � „� R051N bottom (usually a concrete J NOSING S t NOT pad) of the stairway. ANO°1? R!3Y'NI,O E • THAN :VT Figure 30 - Tread and Riser Detail • f i r „..---1 / -7 MAX SPAN = e' -O' 'M2 STR7N3'ERS [ f 1 MAX SPAN = 15'4' AJAX SPAN = ;Cr-3' At) STRINGERS f CUT STRINGER SOLID STRANGER GER Figure 31 — Stair Stringer Requirements I attach 2x tread material vi; stringer 2-#8 screws or 2 -Sd nails per 2x material board at each stringer or ledger . ' • AIIIPAPP. E ifiMat f �1� , >� 1 stringrs 2x4 ledger, each side, full depth of tread; attach / 4-10d nails or #8 wood screws CUT STRINGER SOLID STRINGER 1 Figure 32 — Tread Connection Requirements Note: The stair design in this document is for a three -foot wide maximum stairway with minimum 2x tread material. Plastic or composite decking products may be used for stair treads; however, they may require additional stair stringers for bracing. Check with the manufacturer's requirements. Typical Deck Details revised 2/08 Page 25 of 27 • 5' -O' max between posts stair guardrail required for stairs with a total �a� rise of 3fY or more 4 see TYPICAL GUARDRAIL c. I DETAILS for more information /110 0 R stair guardrail height: 34" measure from nosing of step � .�...: triangular opening shall not permit the passage of a 6' diameter sphere Figure 33 — Stair Guard Requirements BAND BOARD OR OUTSIDE JOIST — 1111111111MM1•111111111111111 1, SLOPED HANGER OR LS5O EACH SIDE Figure 34 — Stair Stringer Connection Detail STAIR HANDRAIL REQUIREMENTS All stairs with four or more risers shall have a handrail on one side. Handrails shall be graspable and shall be of decay- resistant and /or corrosion- 3 -1/2" max. num resistant material. See Figure 35. The hand grip 1 -in min 1 portion, if circular, shall be between naaxirafl 1 and 2" in cross section. Shapes other than circular shall have a perimeter dimension 17 between 4" and not greater than 6 with a corrosion-resistant maximum cross sectional dimension of 2 All handrail hardware shapes shall have a smooth surface with no sharp Figure 35 — Handrail Requirements corners. Handrails shall run continuously from a point directly over the lowest riser to a point directly over the highest riser and shall return to the guard at each end. See Figure 36. Handrails may be interrupted at guardrail posts only at a turn in the stair. Typical Deck Details revised 2/08 Page 26 of 27 �_- F-- : w LT a) . I . Li. .J «) Q .. a 0 Z r 0 1- (7) z ,;-, 0 ct 1, _ _ ,_ _ , cy) z ..... _ _ ____ . _ _ _ _ _ ..._ _ _ .._._ HANDRAIL - i C I HANDRAIL SHALL Emit RETURN AT EACH END . UM -- 4x4 PT POSTS EMBEDDED IN CONCRETE a 36" MAX SPAN . , .. '. ,. BETWEEN ,4 • . STRINGERS ' I FOOTING: 12" x 12" Figure 36 — Miscellaneous Stair Requirements FRAMING AT CHIMNEY OR BAY WINDOW All members at a chimney or bay window shall be framed in accordance with Figure 37. Headers with a span length greater than 6' -0" require a plan submission. 1 6'-0" maximum decking may • 1 extend 6" max. /ii / /ice / /�f ///sir �. f " r / ,. chi / chimney or o r bay �� bay windo a utdo w ledger 4. 'J' . t board i ir ir ir V ,. r . I double joist, double joist double header 2- 1/2'A dia. thru.bolt each side hanger, typ. r - or lag screws at ledger PLAN SECTION Figure 37 - Requirements for Framing at Chimney or Bay Window Typical Deck Details revised 2/08 Page 27 of 27