Loading...
Permit • CITY OF TIGARD MASTER PERMIT PERMIT #: MST2000 -00349 1 C ' DEVELOPMENT SERVICES DATE ISSUED: 9/25/00 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 SITE ADDRESS: 13344 SW 128TH PL PARCEL: 2S104DA -01900 SUBDIVISION: QUAIL HOLLOW - WEST ZONING: R -4.5 BLOCK: LOT: 005 JURISDICTION: TIG REMARKS: S/F PATH I BUILDING REISSUE: STORIES: 2 FLOOR AREAS REQUIRED SETBACKS REQUIRED CLASS OF WORK: NEW HEIGHT: 26 FIRST: 1,575 sf BASEMENT: sf LEFT: 10 SMOKE DETECTORS: Y TYPE OF USE: SF FLOOR LOAD: 40 SECOND: 1,632 sf GARAGE: 671 sf FRONT: 30 PARKING SPACES : 2 TYPE OF CONST: 5N DWELLING UNITS: 1 FINBSMENT: sf RIGHT: 15 VALUE: $ 240,844.77 OCCUPANCY GRP: R3 BDRM: 4 BATH: 3 TOTAL: 3,207.00 sf REAR: 15 PLUMBING SINKS: 1 WATER CLOSETS: 3 WASHING MACH: 1 LAUNDRY TRAYS: 1 RAIN DRAIN: 100 TRAPS: LAVATORIES: 5 DISHWASHERS: 1 FLOOR DRAINS: SEWER LINES: 100 SF RAIN DRAINS: 1 CATCH BASINS: TUB /SHOWERS: 3 GARBAGE DISP: 1 WATER HEATERS: 1 WATER LINES: 100 BCKFLW PREVNTR: 1 GREASE TRAPS: OTHER FIXTURES: MECHANICAL FUEL TYPES FURN < 100K: BOIL/CMP < 3HP: VENT FANS: 5 CLOTHES DRYER: 1 GAS FURN > =100K: 1 UNIT HEATERS: HOODS: 1 OTHER UNITS: 1 MAX INP: btu FLOOR FURNANCES: VENTS: 1 WOODSTOVES: GAS OUTLETS: 1 ELECTRICAL RESIDENTIAL UNIT SERVICE FEEDER TEMP SRVC /FEEDERS BRANCH CIRCUITS MISCELLANEOUS ADD'L INSPECTIONS 1000 SF OR LESS: 1 0 - 200 amp: 0 - 200 amp: W /SVC OR FDR: 1 PUMP /IRRIGATION: PER INSPECTION: EA ADD'L 500SF: 6 201 - 400 amp: 201 - 400 amp: 1st W/O SVC /FDR: 00 SIGN /OUT LIN LT: PER HOUR: LIMITED ENERGY: 401 - 600 amp: 401 - 600 amp: EA ADDL BR CIR: SIGNAL/PANEL: IN PLANT: MANU HM /SVC /FDR: 601 - 1000 amp: 601 +amps- 1000v: MINOR LABEL: 1000+ amp /volt : PLAN REVIEW SECTION Reconnect only: > =4 RES UNITS: SVC /FDR > =225 A.: > 600 V NOMINAL: CLS AREA/SPC OCC: ELECTRICAL - RESTRICTED ENERGY A. SF RESIDENTIAL B. COMMERCIAL AUDIO & STEREO: VACUUM SYSTEM: AUDIO & STEREO: FIRE ALARM: INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM: OTH: BOILER: HVAC: LANDSCAPE/IRRIG: PROTECTIVE SIGNL: GARAGE OPENER: CLOCK: INSTRUMENTATION: MEDICAL: OTHR: HVAC: DATA/TELE COMM: NURSE CALLS: TOTAL # SYSTEMS: Owner: Contractor: TOTAL FEES: $ 4,269.72 KIMBERLY POLINSKY ECK CONSTRUCTION INC This permit is subject to the regulations contained in the GLEN &KIMB RD ERL S.E. PO BOX 204 Tigard Municipal Code, State of OR. Specialty Codes and 26426 1 63 KENT, 63 98042 PO BOX 204 OR 97140 all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if the work is suspended for more than 180 days. ATTENTION: Phone: Phone: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set Reg #: LIC 114755 forth in OAR 952 - 001 -0010 through 952 - 001 -0080. You may obtain copies of these rules or direct questions to OUNC by calling (503) 246 -1987. REQUIRED INSPECTIONS Erosion 844 -8444 Post/Beam Mechanical Mechanical lnsp Framing Insp Gas Line Insp Appr /Sdwlk Insp Sewer Inspection Underfloor insulation Mechanical Insp . Shear Wall Insp Gas Fireplace Electrical Final Footing Insp Crawl Drain /Backwater Plumb Top Out Exterior Sheathing Insr Insulation Insp Mechanical Final Foundation Insp Footing /Foundation Dr< Electrical Service Low Voltage Rain drain lnsp Plumb Final Post/Beam Structural PLM /Underfloor Electrical Rough In Fireplace Insp Water Line Insp Final inspection Issued By : `_ f / - Permittee Signature : Call (503) 639 -4175 by 7:00 p.m. for an inspection needed the next business day CITY OF'TIGARD Residential Building Permit Application Plan Check # ' '7 A. Rec'd By GI/ 13125 SW HALL.BLVD. New Construction Date Rec'd PAD /-it TIGARD, OR 97223 Single Family Detached Date to P.E. Sr- / ' V 503 - 639 -4171 Date to DST _ -A _ ,,✓ F 503 - 684 -7297 / r) , j' Permit #M3ti Print or Type CalledV PI - St t.: d ( 1' 2 a Incomplete or illegible applications will not be accepted SiaL a ow - a` a 31 Name of Project Name / 0, , ,._ , .. c.. „ 6 „ ,..1 / Job Job !QC/or i�f , of Architect Mailing Address Address Site Address /J � � 9 Z Name ,.• City/Stat Zi Phone Owner Mailing Address Name • 7 ' /6 f ' 1 s E' ci /state zip P ne Engineer Mailing Address � der,- 9ioyz s �l5<r7 41,7,0' City /State Zip Phone General Name / - Contractor .tC � 071�rwele z - -.- Describe work New Addition 0 Alteration 0 Repair 0 Mai' g Address to be done: Prior to permit e. , .ea Additional Description of Work: issuance, a copy City/ State Zip Phone of all licenses ,%.-��,t22%:.5 /y 6e_,5' -- /T f are required if Oregon Const. Cont. Boa Exp. Date PROJECT expired in COT Lic.# j t� � r /���J database /177r� 7--/— 02 VALUATION $ / Mechanical Name /� NEW CONSTRUCTION ONLY: Sub- ,re°e7 7<tC Sq. Ft. House: Sq. Ft. Garage_ Contractor Mailing Address ■ Prior to permit Indicate the restricted energy installation by the electrical issuance, a copy City /State Zip Phone subcontractor in the following areas of all licenses Restricted Audio /Stereo are required if Oregon Const. Cont :o r Exp. Date Energy System Alarms expired in COT Lic.# Installations Vacuum Irrigation database (0 36 2, 1 I d System System Plumbing Name �� (check all that Other: Sub - �7,� -c7�s- , /U apply) Contractor Mailing Address Number of Units in Building Unit Number Designation Has the Subdivision Plat recorded? N/A YES NO Prior to permit City /State Zip Phone issuance, a copy of all licenses are Oregon Const. Cont. Boar Exp. Date required if expired in COT Lic.# b 7. database Plumbing Li c.# 2�! Exp. Date I hearby acknowledge that I have read this application, that the information given is correct, that I am the owner or authorized agent L I ' L55 P 6 c / 3, le 1 of the owner, and that plans submitted are in compliance with Name Oregon State laws. Electrical �° / . ''� / -. 7 Le'v .eT /o,? Signature of Owner /Agent Date Sub- Mailing Address f zacc Contact Person Name Phone # Contractor ,��. �/-( o .S r _i ®,s City /State Zip Phone - _�! /�! ye..-6•:..1 eO Prior to permit issuance, a copy FOR OFFICE USE ONLY: of all licenses are . Oregon Const. Cont. Board Exp. Date n 3 Pla #: Map/TL #: required if Lic.# ^ r ' .g J. /O yu /9, /QO0 expired in COT ` "� database EI ical Lic. # Ex•. Da • S s: Zone: ,,L,„,. Pie elvit Electrical Supervisor Li . TIO, e Engineering Approval: Planning Approval: TIF: ll o i:\dsts \forms\sfd- new.doc 11/20/98 CITY OF TIGARD Credit No.: 3 Date Issued: June 8, 2000 • Engineering Authorization Date: June 8, 2000 TRAFFIC IMPACT FEE CREDIT VOUCHER Land Use Casefile No.: 97- 517- PD /S /DHA In accordance with Ordinance 379 Cypress Ventures (name of developer) is entitled to $ 292,254.91 in Traffic Impact Fee Credits that can be applied to TIF EMI Ando charges for development on lot(s) all of the Quail Hollow v WEST Developments. To use this credit, present this form at the time of issuance of the building permit. area Date Permit Numbers Lot Numbers Credit Used Balance Beginning Balance $ 292,254.91 • Balance carried forward to TIF Credit No. • Ordinance 379 provides for an expiration 7 years from authorization. Use Additional pages if necessary. login \viola \tif09.1 CITY OF TIGARD 13125 S.W. HALL BLVD. TIGARD, OR 97223 IMPORTANT PERMIT NOTICE NORTH STAR PLUMBING 1445 SE OREGON ST SHERWOOD, OR 97140 Plumbing Signature Form Permit #: MST2000 -00349 Date Issued: 9 /25/00 Parcel: 2S104DA -01900 Site Address: 13344 SW 128TH PL Subdivision: QUAIL HOLLOW - WEST Block: Lot: 005 Jurisdiction: TIG Zoning: R Remarks: S/F PATH I Your company has been indicated as the plumbing contractor for the permit indicated above. In order for the plumbing permit to be valid, please have the appropriate individual from your company sign below and return this Plumbing Signature Form prior to the start of the work to the address above, ATTN: Building Dept. No plumbing inspections will be authorized until this completed form is received OWNER: PLUMBING CONTRACTOR: GLEN & KIMBERLY POLINSKY NORTH STAR PLUMBING 26426 163RD AVE S.E. 1445 SE OREGON ST KENT, WA 98042 SHERWOOD, OR 97140 — Phone #: 503 - 639 -1279 Phone #: 625 -2679 Reg #: LIC 00090697 PLM 34 -255PB AN INK SIGNATURE IS REQUIRED ON THIS FORM uc ta9.1)0 ture of Authorized Plumber If you have any questions, please call (503) 639 -4171, ext. # 310 STREET TREE CERTIFICATION I, Sfri ,C� /T , OWNER /AGENT FOR 4: (PLEASE PRINT) (PERMIT HOLDER) DO HEREBY CERTIFY THAT THE FOLLOWING LOCATION MEETS WASHINGTON COUNTY LAND USE AND DEVELOPMENT STANDARDS FOR STREET TREE INSTALLATION. ADDRESS: /-1! y /2e? Z;e -C LOT: SUBDIVISION: (ferr< 61A.) le.✓7 • BY: DATE: _1- J- <'c / SIGNAT RECEIVED BY: - - DATE: 7— ( - cr / SIGNATURE — CTTY OF TIGAkO'Bi.IILDING INSPECTION DIVISION 0-. , • 24-Hour Inspection Line: 639-4175 Business Line: 639-4171 ?" 2211-1 - OD3Sq: Date Request Eici - 3 — AM PM BLD Location I, 344) O ■ 2-irk-'-'-- 4 Suite MEC Contact Person 1 3 - ;4-4- 1 )-- 1-1- - Ph (*) S L5 - ( 3(') PLM Contractor 6:AA-A Cd \I i7) SH ph(g) (%C - / I?, SWR . . Tenant/Owner ELC Retaining Wall ELR Footing - MOSS: • *: iv . , la.* - - Foundation = E:'';' .' " . ' ' ' : '',,icr.:' . W4A6,., ' FPS Ftg Drain e, SGN Crawl Drain Inspection Notes:tA _ Slab rrit ir 1 1 et.\ SIT Post & Beam rA 4%43 -evv Ext Sheath/Shear , Int Sheath/Shear 4 Framing .A.,A ..ftrat, Insulation Drywall ‘0(1 Drywall Nailing . Firewall Fire Sprinkler '' - -e.A.)7.---QLA-__ dr.—it L.A...--Nr\ /l.l\ 6 Fire Alarm . r\ . Susp'd Ceiling ......./, c / '--. ... ... ---e) 2 (-A 4-- e 1_,.. -- 7,g Gt,Q misc: --WI Fin PART FAIL al ' 33 \ 7._ ' — YVV\S CJ"( S• . 4.--A 2, 2 H A PASS S' 6k) co' Post & Beam Under Slab I 0 l tAd C.2 Top Out Water Service 1. 00 1 -- -1- " G. S C(/\ -6,-,/1 2:2_ 34 A Sanitary Sewer l Rain Drains 1■6 4 CD b ' - ki■j C Final PASS PART FAIL r / Post eam Rough In LO rAJ Gas Line Smoke Dampers 61 - /L t LL,A Final i / tA / PASS PART 'FAIL ( A ( v (4- i /61/ -) ( 4 ' t i ‘ 1 ' Service LI/ A\A - C\ArtokAl ‘ 1 -t.c ( d" • Rough In / ----- UG/Slab Low Voltage tY\/0 4 (--- KA I- g tkkl kk. ) % 5- 6/ % 3 Fire Alarm Final PASS PART- _ FAIL 1 -' 1 ` 3 't V \A-c-3 4 -1/` - d` (-11\ , \ Backfill/Gradin. Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA A- ) Approach/Sidewalk Date 1 7 1- 2-- - /A A Inspector Ex .... ( - 9 Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION Msr GAG —G63rf 24 -Hour Inspection Line: 639 -4175 Business Line: 6394171 BUP • Date Requested /---/ 0 AM PM BLD Location /33 c( 54 / 2-r&I Suite MEC Contact Person Ph f ? — PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation Pe/u" 7 l h 9 �/J , FPS Ftg Drain 7 /�' Crawl Drain Inspection Notes: SGN Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall 401</4' _ z9 ?eve_ w rvr� ] ��� cl Fire Sprinkler (t/ ` � Fire Alarm Susp'd Ceiling Roof Misc: 901) nn �'�( D�� Final I (-014 f_ ms's' � ' " 'pp- 'e U NC PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call or reins ction RE: [ ] Unable to inspect - no access ADA / , pproach /Si dewalk Date / ` O ( Inspector A 1 l�rz t • t r Exet 7 (�� gr FAIL DO NOT REMOVE this inspection record from the job site. 11 CITY OF TIGARD BUILDING INSPECTION DIVISION MST UO 'G 3 ‘/7 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date � Requested 3.- Z AM PM BLD Location / 3 2 `�l 7 3 " / 2-f Suite MEC Contact Person Ph G, P3 PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Ina Sheath /Shear //� / � 00 �_ _ Framing ��/C/ �I Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL .SITE ackfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access AD pproach /Sidew Date 8—Cb& l Inspector //f h- ��/ Ext 1 Final PASS PAR FAIL DO NOT REMOVE this inspection record from the job site CITY OF TIGARD BUILDING INSPECTION DIVISION ier MS„1 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested 3_7 AM PM BLD Location / 3 3 4./ y 5t /2-0' Suite MEC Contact Person Ph 90 6 3,3 PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final 06A/C PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA proach /Sidewa�� Date Inspector /11,Y4, 4,1, k Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGAItD BUtL.Dr1NG INSPECTION DIVISION ` MS - r • � -bo 24 -Hour Inspection Line %39 -4175 Business Line: 639 -4171 f ��� BUP EO Date Requested AM PM BLD Location 13 7.4-4 Sa) 17 -8 -11 4. I Suite MEC Contact Person Ph cf -c9355 PLM Contractor Ph SWR UILG Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing l Firewall 41 Fire Sprinkle ' Fire Alarm Susp'd Ceiling Roof Misc: m PASS PART FAIL PLUMBING e k--- Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAi. Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PART FAIL CSITE '') Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA / Ext l Other Date , / �/ Inspector F1' PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION g 'f 2 AllgT 4 -Hour Inspection Line £39 -4175 Business Line: 639 -4171 BUP Date Requested ' 7 AM • PM BLD Location / 3,Q' a 5 / 2 ir Suite _ MEC Contact Person Ph � f - "3 93 PLM Contractor Ph SWR 1 et 111.11111ra Tenant/Owner 4 g( C -t _ 7 AGM? CG ELC a ll ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing L�J' U ON.1 L_- • • Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling t Deja.)/UZ__ AMDIAa,-1 Roof CPA SS PART / A� *ire � �!� i� l�lr■ PLUMBING - Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hail, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Date Inspector Ext Final PASS PART FAIL DO NOT REMOVE this inspection ecord from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION ' . M$ • iv 6—�o3yr 24 -hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested ft A PM BLD Location /3 , « s w /ZJ a Suite MEC Contact Person Ph f- 3P 5 PLM Contractor Ph SWR UILDIN Tenant/Owner ELC • g Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Ina Sheath /Shear y� n S Framing , 47 `�W "�S( �-� Insulation w WIT p � U _ A:(?_— c Drywall Nailing V ��/`� �,/� Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof . \ - 1/%--e -- 7.■., (e') G1/4i " k S I �S PART A L ' ` - '�—'L k- ' Y G CAP Post & Beam Under Slab I „ til Top Out Water Service - Sanitary Sewer T r Rain Drains 5 ��� - �_^ ` Ar �a t.... .....--fi 1 ina CHANIOAL Post & Beam Rough In \ /ti \ Gas Line I ) Smoke Dampers na EL CTRICAL Service / \ Rough UG /Slab X , ez. Low Voltage Fire Alarm Final SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA l f Approach /Sidewalk 0 n %/ Other US/A- - e 4L .,, , Date / Inspector �t Ex- Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. • CITY OF TT'IGARD BUILDING INSPECTION DIVISION MST d0 -6 3yr 24 -Hour Inspection Line: 639 -4175 Business Line: 639-4171 / BUP Date Requested 3"/ AM PM BLD Location ) 33 tAy S ct. l 24 bt Suite MEC Contact Person Ph 7' (f -- C* PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain Crawl Drain Inspection Notes: SGN Slab / ALE e.-7L0 191 B u SIT Post & Beam F'r ,J t C u f 444 C �J#9 i G fr C, Z. Pa p74,127) Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: / Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL Service Rough In UG /Slab Low Voltage • harm 014410• ART FAIL Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next i • .ction. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk ✓ l � / Other Date Inspector cT _ Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION - • � . ( ' G a3 <ef f 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 `` BUP Date Requested 3-/ AM / 2j-( PM BLD Location ) 3 2 ( R / 5 ' 1 ' /i Suite ? MEC r Contact Person Ph 9� C 639E 9 PLM Contras r Ph SWR UILDLNO Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain Crawl Drain Inspectio tes: SGN Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing ' ( V ' S D Insulation t-1) \ 4 , i ;� --s'∎ e) S L,�, Wt. Drywall Nailing Vj(� iiY�! " "'V� -rr Firewall CO Fire Sprinkler L� ��✓ Fire Alarm Susp'd Ceiling Roof ` Miss: �.�L 1 in PASS PART _ Post & Beam n� ) Under Slab e V �� k- `v--c Top Out Water Service Sanitary Sewer Rain I -'nsr, 47 r •ART FAIL Post & Beam Rough In Gas Line Smoke Dampers in ASS) PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage / Fire Alarm V Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date 3/ \/0 \ (9 Other Inspector a Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION MST c.,..vO 40 24 - Hour Inspection Line: 639 -4175 Business Line: 639 -4171 �/ • BU f Date Requested 2i '2.d' AM PM BLD Location / 3 3 tl ti S G✓ 7? /Le Suite 'MEC Contact Person Ph PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing � 1 . 74, 49, - -e-�- Firewall Fire Sprinkler / c:) Fire Alarm Susp'd Ceiling "— Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL Service Rough In UG /Slab Low Voltage Fire Alarm ma ASS PART AIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ Unable to inspect - no access ADA / / Approach/Sidewalk Date v �d / Inspec Other E x t Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. OP( OF TIGARD. BUILDING INSPECTION DI`✓ISION ; ( ;,,�r,� 24-Hourtnspection Line: 639 -4175 Business Line: 639 -4171 ,+ BLD BUP Date Request z AM PM / / • Location /3 3 `/ c( 5 6,1 / 01," A Suite MEC Contact Person Ph 9P 37 2i3 PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL 4 ett ost & Beam -- Under SlaL.5A w, h Top Out `` -- 9 ' �y Water Service Sanitary Sewer Rain Drains F• . PART FAIL ANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Z�i j `� ` Other Date / 8 I Inspector Ext3 Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY OF TIGARD BUILDING INSPECTION DIVISION • MST' 2r. = y 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 / BUP Date Requested / Z - i I AM PM BLD Location /,33 ciq S w / Z g t%'t , rK Suite MEC Contact Person Ph 9‘ 4 . 390 PLM Contractor Ph SWR ` BUILDI Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Framing ath /Shear b I ;2 -.1 (Va. � L-QC �� S � a io ► a Nailing 1 1 / 4 --e s / ) SR-- 4 ' - • FirewaN Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PART FAIL UMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date /1- —// Inspector ' Other Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. IF • • CITY CIF BUILDING INSPECTION DIVISION • 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 MST GU 3 • BUP • ' Date Requested / L - 6 AM PM BLD Location /3 34` 5 w / ire> Suite IIAEC Contact Person /34-6 Ph "14 - X 39_3 PLM Contractor Ph SWR UILDiu Tenant/Owner ELC P Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear I lation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misr;: Fin - PART FAIL • BING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading • Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach/Sidewalk Date A 4 O Inspector Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. 3. • , CITY,OI TIGARD BUILDING INSPECTION DIVISION g 24 -Hour Inspection Line: 639 -4175 Business Line: 639-4171 MST. �.�vt� -GV 3y/ / BUP Date Requested / - - S AM PM •BLD • Location (3 3 (1(1 5 w /z 9 Suite MEC Contact Person Ph ?4 f -( 96 PLM Contractor Ph SWR BBLIttDll Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear ns`1" ulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final , 41/ Ok PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL "Frost & Beam moke Dampers Fi. . PART FAIL RICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Date d Inspector 4/e/A,/ Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. • j • •CRY OP TIGARD BUILDING INSPECTION DIVISION ' .• ' • f 24-flour Inspection Line: 639 -4175 Business Line: 639 -4171 ' MST „- rte , l BUP Date Requested // 31) AM PM BLD Location 3 3 (f ..51 /L4 r"A ®K Suite MEC Iry Contact Person Ph ?0 3 ffO PLM Contractor / A , A/ G (14 0"if Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing ` Firewall .. Fire Sprinkler i�� //_ ,■t�l Fire Alarm / Susp'd Ceiling Roof Misc: Final PASS PART FAIL 4' a / AJ( (/9 7 441 PLUMBING NMI 0,I} -6 l-e— r S /Xi,/i L A/ Post & Beam /� Top Under Slab Pi , s / / /+ 'l , / f0� Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam � ) Rough In Gas Line Smoke Dampers Final PASS PART FAIL CZ Service 4tgu2 Ja-' UG /Slab Low Voltage Fire Alarm PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ I Unable to inspect - no access ADA Approach /Sidewalk Other Date I / ` 3V- 9fD Inspector E Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. - • .CITY OF BUILDING INSPECTION DIVISION • s i-GU 3v/ 24 -H6 r Inspection Line: 639 -4175 Business Line: 639 -4171 Date Requested //' 2 4 AM PM BLD, Location / 3 3 4i K 5 6✓ /Z -i it Suite MEC - Contact Person a Ph ,5 - jG 1— f 3 PLM �/ Contractor Ph 724 � 016 - BUILDING Tenant/Owner ELC (YA )- . tO( Retaining Wall ELR ('v ) Footing Access: Foundation FPS Ftg Drain SGN (,)'1V Crawl Drain Inspection Notes: Slab SIT Post &Beam 1-Y Ext Sheath /Shear , Int Sheath /Shear r` Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final P PART FAIL 0 K:',i :1I A u Post & Beam op 0 ater Service OW Sanitary Sewer a■l/ Rain Drains Fi • PART FAIL HANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA l D /f � Approach /Sidewalk Date !!! l i /7j" 1 / U Inspector c..� EX Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. • • • CITY OF TIGARD BUILDING INSPECTION DIVISION MST — G d 3 • 24 -I-tour Inspection Line: 639 -4175 Business Line: 639 -4171 • • • BUP Date Requested t%z AM PM • BLD {, Location /3 3 c( e( .547/27 Suite MEC Contact Person Ph ,9 ? C3,3 PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final PASS PART FAIL U Post & Beam Under Slab / Water Service Sanitary Sewer Rain Drains Final ] PAS • FAIL MECHA AL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk x I �' U Other Date Inspector Ext Final C/ PASS PART FAIL DO NOT REMOVE this inspection record from the job site. • CITY OP TIGARD BUILDING INSPECTION DIVISION ' ' 24 -Hou Inspection tine: 639 -4175 Business Line: 639 -4171 MST • BUP Date Requested fi-.-14 AM PM BLD Location / 3 3 4( b Suite MEC Contact Person Ph f 4 PLM Contractor Ph SWR BUILDIN Tenant/Owner ELC - e arcing Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam /2P Ext Sheath e Int Sheath /Shear Framing /is Tp. e rid .t-/ T 6To 7 �Agl Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: Final Mg PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Date / / - //n— Inspector /f_ Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. • • • CITY OF T,IGARD •BUILDING • INSPECTION DIVISION • ' G iG • 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 MST iC� �� BUP • Date Requested //- AM PM . BLD . Location /33 V C/ S w / L4 Suite MEC Contact Person Ph fq &r 3 f3 PLM Contractor Ph SWR UILDING Tenant/Owner ELC Rea Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheat Int Sheath! ear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access Fire Supply Line ADA Approach /Sidewalk Other Date // 9 — Inspector Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. • CITY dF'TIGARD• BUILDING INSPECTION DIVISION i • - • •—� 24`•(lour Inspection Line: 639 -4175 Business Line: 639 -4171 141ST V • // BLIP ' Date Requested i/ - / Y AM PM BLD Location / 3.3 (it-( 5 4 / - Suite MEC Contact Person /74-i Ph PLM Contractor Ph SWR CLD[_ Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam ..1101.771. i:7{.yiTx.0 Framing Insulation Drywall Nailing Firewall Fire Sprinkler C �`�'L -��' ��� b■. AA, ) 1 1Dl Fire Alarm Susp'd Ceiling 2 C- • '' k Roof Misc: I /JEIE AN1SM, . Final 'ASS ) PART FAIL BING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call r reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date 11 i Inspector Ext Other Final PASS PART FAIL DO NOT EMOVE this inspecti record from the job site. • . • • • . CITY OF TIGARD BUILDING INSPECTION DIVISION . 744 -lour Inspection Line: 639 -4175 Business Line: 639 -4171 MST • BUP Date Requested -� /� AM PM . BLD. Location /3 3 V y . S c� / ?r Suite MEC Contact Person flu 6 Ph 9 3/ � PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam fa ` I�T - � ' f- ii1L•y itto eath /She - Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof 1 1\ �� o R Misc: JJ tt 11 �� Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE BackfilUGrading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other D ate Inspector Ext Final PASS PART FAIL _ DO NOT REMOVE this inspection record from the job site. • CITY ( ,TI6ARD BUILDING INSPECTION DIVISION • I . 24 =Hour Inspection Line: 639 -4175 Business Line: 639 -4171 • • _ , BUP • Date Requested l(J —/ 7 i AM PM • BLD• Location /35 K Suite MEC Contact Person Ph 9 ff - X03 f3 PLM Contractor Ph SWR �BUILDI Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: SIT + � Po — st & Bea Sfieath/Shear Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Misc: 'ART FAIL • MBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final e t t fflikow , FAIL ough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Date /6 / ®d Inspector Ext Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. • ,• CITY dF•TIGARDr BUILDING INSPECTION DIVISION = . T 3y • 24 Hour•Inspection Line: 639 -4175 Business Line: 639 -4171 • BUP - r Date Requested ! —/ AM PM - BLD • Location 13.3 4t q .540 /2_kt fie Suite MEC Contact Person Ph 967 - - P31, PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear ' ) Framing - c 5• (6 Insulation \0)2._ C C ,�"^' - � f ,k 4 w _ + /� 377 Drywall Nailing ��' 1� �.(.J Firewall Fire Sprinkler Fire Alarm I - Susp'd Ceiling + / Li✓� ty C L �� Roof `AA5 ' ∎i e & 7 \J —J c/\ N/U 27 1MS Misc: Final PASS PART FAIL LUMBI ost & Bs4tra> Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final 4 ' Mss PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG(Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA '^ / '� Approach /Sidewalk Date V 1210 0 Inspector EX Z 1 9 Other Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. • ,- CITY O TIGARD BUILDING INSPECTION DIVISION • ' ' MST ` >-uu • 2A -Hbur Inspection Line: 63974175 Business Line: 639 -4171 ' . • BUP • Date Requested /o-. / / AM PM ' BLD• Location,) 33 1 /y 5 w /2-7 &SA Suite MEC Contact Person Ph ,' ,'- 3 f U PLM Contractor Ph SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing le r� / Insulation Drywall Nailing I A '% // i/ � Firewall �� � � , Fire Sprinkler / A - Fire Alarm / Susp'd Ceiling _ Roof / Misc: i / . wA , �! Final PART FAIL ~ _ - ��� '1 11)Wv— 7--1.Z-Z----------- 0 Un er lab Top Out Water Service Sanitary Sewer Rain Drains F c •A PART FAIL •..I . ► Roug - rn Gas Line Smoke Dampers I A PART FAIL TRI CAL Service 1 Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access Fire Supply Line ADA 7 Approach /Sidewalk i J� ,( Other Date ' U u Inspector � � Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. CITY.OF TIGARD BUILDING INSPECTION DIVISION 24.1-Iour.Inspection Line: 639 -4175 `Business Line: 639 -4171 MST 1�lir UL� 3 � 9 • / BUP • Date Requested < - AM PM . BLD . Location x33 V .S k Suite MEC Contact Person 5/"P �-� Ph �(�/ .3 70 PLM Contractor Ph SWR I Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Dr -•- SGN Inspection Notes: •. SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation 1 Drywall Nailing U Firewall Fire Sprinkler _ Fire Alarm Susp'd Ceiling Roof Misc: Fi PART FAIL UMBING Post & Beam Under Slab Top Ou Final PART FAIL CHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk J 0 1 r1/ f Other Date l / G Inspector Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. S - • • O ' Cnil0F:"7IGARD BUILDING INSPECTION DIVISION - • ' ' - ci 24 Jioar Inspection Line: 639 -4175 Business Line: 639 -4171 M S T V e U, �' �� I / • • BUP • • Date Requested 9 l 2 - 7 AM PM . BLD Location ( 3 `I( � C , C ) 1 ? M Pi Suite MEC Contact Person Ph 16 9- 6 PLM Contractor Ph SWR BUILDING Tenant/Owner ELC -- - •• • Wall ELR ooti • Access: ouna - FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear 1 Int Sheath /Shear Framing - /; re,Ai d r° Le7V/P c. Insulation Drywall Nailing G' r z' C Firewall Fire Sprinkler ? /Ai S7144..• lit! Leo ' A.s 4-S ..5344 44 A/ /:d S a /7-4.1C 1102 Fire Alarm Susp'd Ceiling h7.1f Roof Fi / / AS PART FAIL ' ' ` — re — Yc�cf 0 7 �--- /A., ' • PL MBING 6P , r_ --7-- (--- o Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL ' MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final PASS PART FAIL SITE Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hail, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other Date 5: 2 7 Gl i Ins Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. F • CITYb . TIGARD BUILDING INSPECT • . • 'r SIO` - . _ • • -Hour inspection Line: 639 -4175 'Bd. mess L' e: 639 -4171 / A BUp Date Requested q( 2101 • , _ ' BLD Location l SG) c.2.44- Pi Suite MEC Contact Person Ph `'O? — 023e PLM Contractor Ph SWR I I UJLDING� Tenant/Owner PLC Re ' "•g Wall ELR o a • • 40,4 Access: ound g gain , ` " SGT A. Crawl Drain Inspection Notes: , Slab SIT Post & Beam Ext Sheath /Shear Ina mingth /Shear 0 1.ev\c, y \'s Framing � ��� �i� Drywall Insulation C" U �i Drywall Nailing C. ` Fire S NO—, / (,�& Fire Sprinkler V C.N e..' Fire Alarm 7 2_ \ V 1 Susp'd Ceiling ( Roof Misc: ,9 ^ ` ,, Final �S V S �.?°V ' v V `S Qe J 1-- `� �`" �, .� PASS PART �� PLUMBING f �� Post & Beam Under Slab /� Top Out L� V `-A5 %-' S SAS Water Service Sanitary Sewer Rain Drains Final . PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS PART FAIL ELECTRICAL Service Rough In UG /Slab Low Voltage Fire Alarm Final P S PART FAIL IT Bac fill /Grading Sanitary Sewer t p, Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA A roach /Sidewalk V7/40/6 /� , Z 1 9 acr s , ate Inspector � (/' Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. • a . ' • .� • r+ r • MST — Master Permit ' • • • • Inspection Description Date Passed By Notes Grading ' Footing /Setback y- Z7- 00 Foundation walls q- Z7- 06 Slab Footing drain - Waterproof basement walls - - Plumbing underslab Crawl drain f 1 Qrj 1 ha Post/beam plumbing ,a'G /-73 Post/beam mechanical / /0 6 12'74 Underfloor insulation I Post/beam structural /0-/ 7,0 0 Shear walls/anchors r / /-c-oo Exterior sheathing {1 r /6/ V //?! Plumbing top -out ` 1(i7 Ga it; iV-1.4/6 & .'�,5 Gas line & test 1 Z 7G Cr Mechanical rough -in / Z5/6 L 2 4 2 Electrical rough -in f/ 3 D - Electrical service // -3° - BOO Low voltage Sprinkler rough -in ' Backflow preventer Roof nailing Firewall Framing Jv 6p /tl 4 MFG -Home set -up Insulation t'L-1•-od r,.A Drywall nailing - - /lVfl- Masonry/Reinforcement - Rain drain b134el k Sanitary sewer (072/44 "-./' Water service 1 2/A e ,7 Pump /fill septic tank Approach /sidewalk 3 / 7CA ✓y1 Grading final i7--t? I te Mechanical final 3 l,0 1 Plumbing final V) / Electrical final 3/I / la Final inspection 3---t/- Special Reports SWR - Sewer Permit S uh2 altrov — 00 2 3 cp I Inspection Description Date Passed By Notes Sanitary sewer Final inspection INSPECTION RECORD - MST (MASTER) PERMITS 1 •- ! . . ' . , , \ CITY OF T A D MASTER PERMIT ' PERMIT #: MST2000 -00349 # DEVELOPMENT SERVICES DATE ISSUED: 9/25/00 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 SITE ADDRESS: 13344 SW 128TH PL PARCEL: 2S104DA -01900 SUBDIVISION: QUAIL HOLLOW - WEST ZONING: R -4.5 BLOCK: LOT: 005 JURISDICTION: TIG REMARKS: S/F PATH I BUILDING REISSUE: STORIES: 2 FLOOR AREAS REQUIRED SETBACKS REQUIRED CLASS OF WORK: NEW HEIGHT: 26 FIRST: 1,575 sf BASEMENT: sf LEFT: 10 SMOKE DETECTORS: Y TYPE OF USE: SF FLOOR LOAD: 40 SECOND: 1,632 sf GARAGE: 671 sf FRONT: 30 PARKING SPACES : 2 TYPE OF CONST: 5N DWELLING UNITS: 1 FINBSMENT: sf RIGHT: 15 VALUE: $ 240,844.77 OCCUPANCY GRP: R3 BDRM: 4 BATH: 3 TOTAL: 3,207.00 sf REAR: 15 PLUMBING SINKS: 1 WATER CLOSETS: 3 WASHING MACH: 1 LAUNDRY TRAYS: 1 RAIN DRAIN: 100 TRAPS: LAVATORIES: 5 DISHWASHERS: 1 FLOOR DRAINS: SEWER LINES: 100 SF RAIN DRAINS: 1 CATCH BASINS: TUB /SHOWERS: 3 GARBAGE DISP: 1 WATER HEATERS: 1 WATER LINES: 100 BCKFLW PREVNTR: 1 GREASE TRAPS: OTHER FIXTURES: • MECHANICAL FUEL TYPES FURN < 100K: BOIUCMP < 3HP: VENT FANS: 5 CLOTHES DRYER: 1 GAS FURN > =100K: 1 UNIT HEATERS: N00DS: 1 OTHER UNITS: 1 MAX INP: btu FLOOR FURNANCES: VENTS: 1 WOODSTOVES: GAS OUTLETS: 1 ELECTRICAL RESIDENTIAL UNIT SERVICE FEEDER TEMP SRVC /FEEDERS BRANCH CIRCUITS MISCELLANEOUS - ADDL INS "t: CTIONS 1000 SF OR LESS: 1 0 - 200 amp: 0 - 200 amp: W /SVC OR FDR: 1 PUMP/IRRIGATION: PER INSPECTION: EA ADD'L 500SF: 6 201 - 400 amp: 201 • 400 amp: 1st W/O SVC/FDR: 00 SIGN /OUT LIN LT: PEP HOUR: LIMITED ENERGY: 401 • 600 amp: 401 - 600 amp: EA ADDL BR CIR: SIGNAL/PANEL: IN PLANT: MANU HM /SVC /FDR: 601 - 1000 amp: 601 +amps- 1000v: MINOR LABEL: 1000+ amp /volt : PLAN REVIEW SECTION Reconnect only: > =4 RES UNITS: SVC /FDR> =225 A.: > 600 V NOMINAL: CLS AREA/SPC OCC: ELECTRICAL - RESTRICTED ENERGY _ A. SF RESIDENTIAL B. COMMERCIAL AUDIO & STEREO: VACUUM SYSTEM: AUDIO & STEREO: FIRE ALARM: INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM: OTH: BOILER: HVAC: LANDSCAPE/IRRIG: PROTECTIVESiGNL: GARAGE OPENER: CLOCK: INSTRUMENTATION. MEDICAL: OTHR: 1 HVAC: DATA/TELE COMM: NURSE CALLS: TOTAL # SYSTEMS: Owner: Contractor: TOTAL FEES: $ 4,269.72 This permit is subject to the regulations contained in the GLEN & KIMBERLY POLINSKY ECK CONSTRUCTION INC Tigard Municipal Code, State of OR. Specialty Codes and 26426 163RD AVE S.E. PO BOX 204 all other applicable laws. All work will be done in KENT, WA 98042 SHERWOOD, OR 97140 accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if the work is suspended for more than 180 days. ATTENTION. Phone: Phone: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set Reg #: LIC 114755 forth in OAR 952 - 001 -0010 through 952 -001 -0080. You may obtain copies of these rules or direct questions to OUNC by calling (503) 246 -1987. ti REQUIRED INSPECTIONS Erosion 844 -8444 Post/Beam Mechanical Mechanical Insp Framing Insp Gas line Insp Appr /Sdwlk lnsp Sewer Inspection Underfloor insulation Mechanical lnsp . Shear Wall Insp Gas Fireplace Electrical Final Footing Insp Crawl Drain /Backwater Plumb Top Out Exterior Sheathing Ins F Insulation Insp Mechanical Final Foundation Insp Footing /Foundation Dr; Electrical Service Low Voltage Rain drain Insp Plumb Final gi Post/Beam Structural PLM /Underfloor Electrical Rough In Fireplace Insp Water Line lnsp Final inspection Issued By : - ` •' / - Permittee Signature 1 – 7— Call (503) 639 -4175 by 7:00 p.m. for an inspection needed the next business day