Plans . ..
ABBREVIATIONS ELECTRICAL NOTES INDEX LEGEND • + ! • :.'LICENSE
• . : •
•
• • •
1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET
AC AM ER CURRENT MEANS MAY BE ENERGIZED IN THE OPEN PV2 SITE PLAN 0 (E) UTILITY METER (6) OR # 180498
• .•. •• ':
BLDG BUILDING POSITION, A SIGN WILL BE PROVIDED WARNING PV3 STRUCTURAL VIEWS INVERTER W/ INTEGRATED DC t'S!O . . . ; .
CONC CONCRETE OF THE HAZARDS PER ART. 690.17. PV4 UPLIFT CALCULATIONS • • •
2. EACH UNGROUNDED CONDUCTOR OF THE PV5 SINGLE LINE (3),(4),(5),(6) • • •
C COMBINER BOX
D DISTRIBUTION MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PV6 ELECTRICAL CALCULATIONS oc
DIRE PANEL
DC DIRECT CURRENT BY PHASE AND SYSTEM PER ART. 210.5.
PV7 CUTSHEETS F. DC DISCONNECT (4),(5)
r.
EGC EQUIPMENT GROUNDING CONDUCTOR 3. A NATIONALLY - RECOGNIZED TESTING PV8 CUTSHEETS
(E) EXISTING LABORATORY SHALL LIST ALL EQUIPMENT IN PV9 CUTSHEETS �� AC DISCONNECT (3),(4),(5),(6) • „ ... :•• JUR I'SDICTION NOTES
EMT ELECTRICAL METALLIC TUBING COMPLIANCE WITH ART. 110.3. PV10 VENT SPAN DETAIL
G SOLAR GUARD METER 4. CIRCUITS OVER 250V TO GROUND SHALL 0 GALV GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) JUNCTION BOX
GEC GROUNDING ELECTRODE CONDUCTOR 5. DC CONDUCTORS EITHER DO NOT ENTER
CND GROUND BUILDING OR ARE RUN IN METALLIC RACEWAYS GENERAL NOTES DC COMBINER BOX (7),(9) RECEIVED
HDG HOT DIPPED GALVANIZED OR ENCLOSURES TO THE FIRST ACCESSIBLE DC
I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). APR 2 6 2011
Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN 1. THIS SYSTEM IS GRID - INTERTIED VIA A 0 DISTRIBUTION PANEL (1),(2)
INVS INVERTERS RELIEF AT ALL ENTRY INTO BOXES AS UL- LISTED POWER- CONDITIONING INVERTER. CITY OF TIGARD
Isc SHORT CIRCUIT CURRENT REQUIRED BY UL LISTING. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. Lc LOAD CENTER (3),(4),(5),(6)
kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE 3. ALL INVERTERS AND ARRAYS ARE NEGATIVELY BUILDING DIVISION
kW KILOWATT UL- LISTED LOCATION PROVIDED BY THE GROUNDED.
LBW LOAD BEARING WALL
MANUFACTURER USING UL LISTED GROUNDING 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED O DEDICATED PV SYSTEM METER erg d
MIN MINIMUM HARDWARE. 5. ALL WORK TO BE DONE TO THE 2010 OBC — CONDUIT RUN ON EXTERIOR
(N) NEW 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, BASED ON THE 2009 IBC. - -- CONDUIT RUN ON INTERIOR
NEC NATIONAL ELECTRIC CODE RAIL, BOXES, ETC.) SHALL BE GROUNDED USING 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE — GATE
NIC NOT IN CONTRACT UL LISTED LAY -IN LUGS LISTED FOR THE CURRENT NATIONAL ELECTRIC CODE AS AMENDED
NTS NOT TO SCALE PURPOSE. POSTS SHALL BE MADE BY THE OREGON ELECTRICAL SPECIALTY CODE.
OC ON CENTER ELECTRICALLY CONTINUOUS WITH ATTACHED
P PANEL BOARD R
OFFICE COPY
PL PROPERTY LINES 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE
PV PHOTOVOLTAIC BONDED WITH EQUIPMENT GROUND CONDUCTORS
PVC POLYVINYL CHLORIDE AND GROUNDED AT THE MAIN ELECTRIC PANEL.
S SUBPANEL 10. IF THE EXISTING AC GROUNDING ELECTRODE IS VICINITY MAP
SCH SCHEDULE A COPPER ROD, THE DC GEC SHALL BE EITHER
SS STAINLESS STEEL #8 THWN -2 RUN INSIDE CONDUIT BONDED AT
SSD SEE STRUCTURAL DRAWINGS BOTH ENDS, OR #6 BARE COPPER RUN ALONG CITY OF TIGARD
STC STANDARD TESTING CONDITIONS BUILDING AS LONG AS IT IS NOT SUBJECT TO -„ S',N Fans . A pproved
SWH SOLAR WATER HEATER PHYSICAL HARM PER ART. 250.166(B) &(C), g C 4C 1
TYP TYPICAL 250.64(B) &(E). IF THE EXISTING AC GROUNDING 1. Conditionally Approved [ ]
UON UNLESS OTHERWISE NOTED ELECTRODE IS A CONCRETE-ENCASED 4 [ ]
� S'N � S ee Letter to: Follow
UPS UNINTERRUPTIBLE POWER SUPPLY ELECTRODE, THE DC GEC SHALL BE A #6 Q Attached [ ]
VOLT ? SW Ntlhrrew Or
V THWN -2 PER ART. 250.166(D). THE GEC SHALL p, PermitNumberl 0008"
Vmp VOLTAGE AT MAX POWER < Id *Jua
Vo P VOLTAGE AT OPEN CIRCUIT BE CONTINUOUS AS DESCRIBED IN ART. �, 4k (+ Address: 1 SW 11 4 I'M.
W WATT 250.64(C). 4 By: 6' • L. p1 Date: 5• LI. 11
3R NEMA 3R, RAIN TIGHT S t * y SW Guide St a, SW McDonald St co
d
4 Q REV BY DATE COMMENTS
t 10 REV • • r /*/t •
0 r
C4 .-
`y
CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J B-972408 00 PREMISE OWNER: AHJ: TIGARD, OR DESCFIPTION: DESIGN: ` Ibillid '
CONTAINED SHALL NOT BE USED FOR THE FRISIRAS, CHRIS FRISIRAS RESIDENCE TA �'
' ���SoiarCi t y
BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES:
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (20) YINGLI # YL230P 29b 14055 SW 116TH TERR 4.6 KW ROOF MOUNT PV SYSTEM
PART OTHERS OUTSIDE THE ECCIOIENTS
ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM: TH TIGARD , OR 97224 �/1 3055 Clearview Way
THE SALE AND USE OF THE RESPECTIVE SOLARCITY CANOPY -C W/ EXTENDERS
SOLARCITY EQUIPMENT. WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE San Mateo, CA 94402
PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: ) 6 F:(650) 638 -
_EASE (1) FRONIUS # IG 4000 5039682730 COVER SHEET PV 1 4/19/2011 (888) :(65 C 0 lfyn65 38 -102 8 9, I ww 6 3s 8 arc029 ity.com
• • • • ••
• .. • • - ; •
• ••
• • • • •
20' ATTACHMENTS SHALL BE SPACED NO
GATE TO t GREATER THAN 24 INCHES ON CENTER • •
1 IN ANY DIRECTION WHERE ARRAY IS • • • • • • •
❑ LOCATED WITHIN 3 FEET OF A ROOF . : • • • • ••: •
EDLS • • • • • • • • • ••• •••
• ••
0818C 306.4.3 (B)
S • •• S.
• ••• ••• •• • •
• • • • • • • • • •
•
LEGEND
VENT SPAN.51* 05 .4 • . 6
DETAIL ON PV10 Q (E) UTILITY METER (6)
MI INVERTER W/ INTEGRATED DC DISCO
30' — -17-1- - - - � FIRE 1'
SETB ' K ® (3),(4),(5),(6) [_..._
H TO R Q FRONT OF HOUSE ® DC DISCONNECT (4),(5)
H
30' 6 AC DISCONNECT (3),(4),(5),(6)
TO t Nn
(TYP) 0 JUNCTION BOX
B
PV3 MP2 ROOF MOUNT ' Q DC COMBINER BOX (7),(9)
PITCH: 30 ARRAY PITCH: 30 rn
AZIMUTH: 180 ARRAY AZIMUTH: 180 Q DISTRIBUTION PANEL (1),(2)
C)
ROOF MATERIAL: Comp Shingle Roof r,
PENETRATION AO SON � U IT STORY: 2 0 LOAD CENTER (3),(4),(5),(6)
A I Low�o
ROOF. . RAFTERS
PV3 + M 30 SIZE: 2x8 O DEDICATED PV SYSTEM METER
P ' �" ' SPACING: 24" O.C. — CONDUIT RUN ON EXTERIOR
MP1 ROOF MOUNT SUPPORT: 2x10 RIDGE BEAM - -- CONDUIT RUN ON INTERIOR
PITCH: 30 ARRAY PITCH: 30 MAX. SPAN: 9' -11" — GATE
_ _ _ _ _ _ _ _
AZIMUTH: 180 ARRAY AZIMUTH: 180
ROOF i r
MATE Comp Shingle Roof PENETRATION ; r DC Inv ,' '¢M °r� D N0 0 5 PLY SHEATHING
STORY: 2 . I
y . L«_� -i
RAFTERS ❑
0
SIZE: 2x8 GATE C 10'
SPACING: 24" O.C. PV3 TO R
SUPPORT: 2x10 RIDGE BEAM
MAX. SPAN: 11' -11" r' — 1 I N
❑ I TOTAL ARRAY AREA: 352' I SITE PLAN w 41911 E
NOTES STRUCTURE MEETS THE I TOTAL ROOF AREA: 2011' I Scale: 1/8" = 1' `+
0.5" PLY SHEATHING PRESCRIPTIVE REQUIREMENTS OF
THE OSISC SECTION 305.4 I TOTAL ARRAY AREA IS -17.5% I S
I OF TOTAL ROOF AREA. I 0 1' 8' 16'
■•• ■
L- J •
CONFIDENTIAL - THE INFORMATION HERON JOB NUMBER: J B-972408 0 0 PREMISE OWNER AH.I TIGARD, OR DES(»'1II : DESIGN: `i tsd
CONTAINED SHALL NOT BE USED FOR THE FRISIRAS, CHRIS FRISIRAS RESIDENCE TA WHOLE ; � ; •
BENEFIT OF ANYONE EXCEPT SOLARCITY INC., HARLOT: MODULES • SolarCity
NOR SHALL IT BE DISCLOSED IN OLE OR IN REST (20) YINGLI # YL23OP -29b 14055 SW 116TH TERR 4.6 KW ROOF MOUNT PV SYSTEM 0
PART TO OTHERS OUTSIDE THE RECIPIENTS 0.EC AGER MOUNTING SYSTEM: ORGANIZATION, EXCEPT IN CONNECTION WITH , PRT MAN TIGARD OR 97224
� 30 55 Clearvewway
THE SALE AND USE OF THE RESPECTIVE SOLARCITY CANOPY -C W/ EXTENDERS PAGE NAME SHEET: REV: DATE S Mateo, CA 94402
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: INSERTER: 638 -1028 I F:(650) 638 -1029
PERMISSION OF soLARaTY INC. _EASE (1) FRONIUS # IG 4000 5039682730 SITE PLAN PV 2 4/19/2011 (888) SOL -C1TY(765 - 2489) I www solardty . corn
'Y r L:1-1-14*:
• • • • • • • • •
..•
• • • S •
• • •
. •
SOLAR PANEL • • • • : ' 34TWEEN• •
ATTACHED WITH MODULE INSTALLATION ORDER • • • •/ . • . •�
FOOTINGS•• •
CLAMPS, " -16 BOLTS, / LOCATE RAFTER, MARK HOLE • •
AND CHANNEL NUT LOCATION, AND DRILL PILOT
SOLARCITY SOLAR RAIL,i (1) HOLE. CUT SHINGLE AROUND _. ' • -- • • • ••• :
EXTENDER & BOLT 1 (4) \ FLASHING. • - . • . . .. - • .
CANOPY CLAMP i ' •—•-•••(•_ ASSEMBLY (3) / SEAL PILOT HOLE AND BOTTOM • • • t : : • • • 1.1
CANOPY FLASHING Al ( OF CANOPY BASE WITH N ' & BRACKET (1) \ POLYURETHANE SEALANT.
/ LAG CANOPY BRACKET INTO
(E) COMP. SHINGLE ' ' (3) RAFTER
s- ��-� »� 1 X
WITH (2) a" DIA. LAG
BOLTS. 2' TYP
(E) ROOFDECKING /'NSTALL CANOPY FLASHING ONTO (E) 2x8 RAFTERS
" DIA LAG BOLT ( BRACKET. ATTACH RAIL WITH ® 24" SPACING
CANOPY BOLT.
(2 -3" EMBED, MIN)
(E) RAFTER STAN DOFF FRONT VIEW OF MOUNTING PLANE
D / B Scale: 1 1/2" = 1' Scale: 1/2 " =1' -0"
i
eh (E) 2x10 Q -� (E) 2x10
�� RIDGE BEAM , RIDGE BEAM
(E) 2x6
11111 (E) 2x8 RAFTER COLLAR TIES
(E) 2x8 ' (E) 2x8 RAFTER
CEILING JOIST
'; ' A (E) 2x8
3 0' CEILING JOIST
A1' -8 "" •' -11"
N (E) LBW
1
RAFTERS: 2x8 @ 24" O.C. STRUCTURE MEETS THE 8 -
(E) LBW 11
SUPPORT: 2x10 RIDGE BEAM PRESCRIPTIVE REQUIREMENTS {
MAX SPAN: 9' -11" OF THE OSISC SECTION 305.4 RAFTERS: 2x8 @ 24" O.C. STRUCTURE MEETS THE
SUPPORT: 2x10 RIDGE BEAM PRESCRIPTIVE REQUIREMENTS
MAX SPAN: 11' -11" OF THE OSISC SECTION 305.4
SIDE VIEW OF MOUNTING PLANE 2
O Scale: 1/4 " =1' -0" A '
SIDE VIEW OF MOUNTING PLANE 1
Scale: 1/4 " =1' -0"
CONFIDENTIAL — THE INFORMATION HEREIN JCB NUMEER J B- 9 7 2 4 0 8 0 0 PREMISE OMNER ANA: TIGARD, OR DESCRIPT k DESIGN: ` 10�� "
CONTAINED SHALL NOT BE USED FOR THE FRISIRAS, CHRIS FRISIRAS RESIDENCE TA � :
N OR 1 IT BE DI�O IN litICEE OIRRCIN MARKET: RE ST M (20) ODULES: YINGLI # YL230P -29b 14055 SW 116TH TERR 4 .6 KW ROOF MOUNT PV SYSTEM • S oiarCity PART TO OTHERS OUTDE THE RECIPIENTS RE (20)
PROJECT MANAmt TIGARD, OR 97224 MOUNTING SYSTEM: / �
ORGANIZATION, EXCEPT IN CONNECTION WITH � /{ 3055 Clearvew Way
THE SALE AND USE OF NE RESPECTIVE SOLARCITY CANOPY -C W/ EXTENDERS PAGE NAME SHEET REV: DALE San Mateo, CA 94402
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE INVERTER: T:(6) 63s -1028 I F:(650) 638 -1029
PEPERMISSION aF soLARCITY INC. _EASE (1) FRONIUS # IC 4000 503968273 STRUCTURAL VIEWS PV 3 4/19/2011
( ass ) -SOL - (765 -2489) wwwsolarciry.com
• • • . •.
'_ . - . _ ' `_`_aw ' - _
UPLIFT CALCULATIONS ..'• • '' • •
..• • • • • - ••• ;••
•• • •
_ . . .
Input Variables Calculations and Values
• •
Required Variables Design wind pressures based upon: • • • • • • • • •
•
Mean roof height: 25 ASCE 7 -05 Chapter 6 Wind Loading • • • •. •. • •. • •
Exposure category: C •
Basic wind speed (or city in the future): 85 Equation 6.5.13.3: Component and Cladding Elements
Importance factor (1 for residential): 1 Wind pressure P = qh *Cn *G ... "• . •
• . . . • •
• • • • •
Roof shape: pitched 6.5.10: Velocity pressure ; ... • •
Roof angle (degrees): 30 qh = 0.00256 *Kz *Kzt *Kd *VA2 *I
Roof zone: 3
Contiguous sq. feet of array: 70 From Table 6 -3:
Least width of the building: 25 Kz = 0.94
Obstructed wind flow? FALSE From Figure 6-4:
Kzt = 1.00
Local Topograhphical Features From Table 6-4:
(choose "standard "or refer to pictures right, and below) Kd = 0.85
Type of hill: none From figure 6 -1:
Hill height (h) (ft): V = 85
Slope of hill (degrees): From table 6 -1:
Horizontal distance from hilltop to house (x): I = 1
eight from bottom of hill to mean roof height (z):
From Velocity Pressure Equation:
qh = 14.78
Design Wind Pressures From Figure 6 -19B
P (lbs. per sq. ft.) = qh *Cn *G Cn (uplift) = -0.90
Pd (downforce pressure) = 16.33 Cn (down) = 1.30
Pu (uplift pressure) = -11.31 From 6.5.8.1
G = 0.85
Max Tributary Area Feet Inches
Individual Rows in Portrait X (E -W distance between standoffs) = I 4 0
Yingli YL230 P -29b Y (N -S distance between standoffs) = ' 2 8
Amax (sq. ft.) = 0.5 *L *X
L (length of panel in ft. perpendicular to rail) 5.42
X= 4.00 Module Rail Max. Span / Cantilever (in) = 90 42 1/2
Y = 2.67 Max Uplift Force on a Single Standoff
L = N/A Pmax (lbs.) = Amax *Pu
Amax = 10.83 I Pmax = -122
Factor of safety = FI *D *NI /Pmax
250 = Fl (pullout capacity of lag (lbs/inch))
Dead Load Calculations 2.50 = D (minimum lag thread depth)
DL (Ibs/sq. ft.) = (Mm +Mh) /(L *W) 2 = NI (number of lags per standoff)
L (length of Yingli YL230 P -29b modules) 5.42 10.25 = Factor of safety
W (width of Yingli YL230 P -29b modules) 3.25
Mm (weight of Yingli YL230 P -29b modules) 43.70 Point Load Calculations
Mh (weight of hardware per module) = 8.03 PL (Ibs) = Amax *DL
I PL= 32
DL = 2.94 Version 6_8
CONFIDENTIAL - THE INFORMATION HEREIN J06 NUMBER: J B- 9 7 2 4 0 8 0 0 PREMISE OWNER: AN,: TIGARD, OR DESCRIPTION: DESIGN: ` v b idd
CONTAINED SHALL NOT BE USED FOR THE TA � z f � i
FRISIRAS, CHRIS FRISIRAS R ES I DE N CE ./', �
BENEFIT SHALL OF IT ANYONE
BE E DISCLOSED D IN WHOLE INC., MARKET: MODULES:
) YINGLI # YL230P -29b
NOR 14055 SW 116TH TERR 4.6 KW ROOF MOUNT PV SYSTEM ' y
SH IT BE DCLOSD IN WHOLE OR IN REST (20
PART TO OTHERS OUTSIDE THE RECIPIENTS PR0.ECT MANAGER MOUNTING SYSTEM: �
ORGANIZATION, EXCEPT IN CONNECTION WITH T IGARD, OR 97224 /! 3055 Clearview Way
THE SALE AND USE OF THE RESPECTIVE SOLARCITY CANOPY —C W/ EXTENDERS PAGE NAME: SHEET: ROY: DATE: San Mateo, CA 94402
SOLARCITY PERMISSION EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE INVERTER: (65 I F:(650) 638 - 1029
PERMISION OF SOLARCITY INC. _EASE (1) FRONIUS # IG 4000 503968 UPLIFT CALCULATIONS PV 4 4/19/2011 (888) -S -CITY 0) (765 - 638 102 2489) I www solarclry.com
• : • • • •
MODULE VOLTAGE RATINGS • • • • • • • • • • • . • • • • • • •
Voc: 37 VDC • • • • . • • •
•
Vpmax: 29.5 VDC
- (20) YINGLI # YL230P -29b
*MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN THE PV Module; 230W, 206.6W PTC, MC4 ram eR • •• • ••• S.
DC STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. • : • • • • •
(4) AWG #1d USr 2 /RHW -2, Black
METER NUMBER: 23138288 r (N) ARRAY GROUND PER 690.47(D). NOTE: PER , _ _ _ o - (1 ) AWG #6, Stranded Bare Copper
EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE : � i I I i I i �J �J •1
H I • :' •'1 )eald : Kii; :, " :EM
I REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE. : I _ _ 1r_ Pi oc- I • :. :•Vo>r' : =;�71J YD�
I I J Pi A' A Pi ii Pi ei ei Pi GND I I • • •• •• Vnip •= VDC
AWG #6, Stranded Bare Copper (1 ) --- . r GEC , - Q ' I ISC = 8.4 ADC
16 MODULES ON MP1 I •
I • Imp = 7.8 ADC
I 4 MODULES ON MP2
Ground Rod; 5/8" x 8', Copper (1) -; I � (1 ) SHOALS # STG.ICU.M4.F
L J Connector; MC4 U -Joint Connector, Female
(1 ) CUTLER- HAMMER # BR225 i i ( 1 ) SHOALS # STG.ICU.M4.M
Breaker; 25A, 2 -Pole I I Connector; MC4 U -Joint Connector, Male
25A PV BACKFEED EGC DC - DC+ LOCATED UNDER ARRAY
AC DISCONNECT
(E) 200A MAIN ELECTRIC SERVICE PANEL PER ART. 690.17
(E) 200A/2P MAIN CIRCUIT BREAKER FRONIUS # IG 4000 (1 )- ( 2 ) AWG USE-2/RHW-2, Black
# 10, USE -2 /
Inverter; 4000W, 240V, 500VDC, 94% EFF. i i 1 AWG #6, Stranded Bare Copper EGC
THOMAS AND BETTS PANEL TBB20(20 LABEL INVERTER: A ( ) pp
(E) WIRES AND CONDUIT Q (1) Conduit Kit; 3/4" EMT • Voc = 370 VDC
(1) AWG #10, THWN -2, Black I '
'
'- ( 1 ) AWG #10, THWN -2, Red r i i • Vmp = 295 VDC
- ( 1 ) AWG #10, THWN -2, White Neutral INVERTER
❑N i i • Isc = 16.8 ADC
•�`. 4.R.- - ( 1) AWG #10, THWN -2, Green EGC GFP i LINE • Imp = 15.6 ADC
• D
( E) LOADS - (1) Conduit Kit 1/2" EMT GN
Z Ii . In IC
I I I
�, i G o �i � ill!
I, 14 • • Vmp = 240 VAC I I , - I I I I I
I I I I I ( 1 ) CUTLER - HAMMER # DH361UGK
f
• Imp = 16.67 MC I I I I I I EGC DC - DC Disconnect; 30A, 600Vac, Non - Fusible, NEMA 1
14 14 �n 1 f 11 I LOAD BI -WIRED TO USE FULL RATING
• L - ••• I L r - - I - -1 I I LOCATED IN GARAGE NEXT TO INVERTER
I BOTTOM • • TOP L1 I I I LEez_ _ _ J ,
I
1 1- L2 I LDC- J
N N I DC+
c EGC EGCJ I 6 U Z - - - (1) AWG #10, THWN -2, Black
TO 120/240V
, 4- (1 ) AWG #10, THWN -2, White
SINGLE PHASE L GE - GEC _ - -GEC - ( 1 ) AWG #6, THWN -2, Green GEC
UTILITY SERVICE I GE # I -70S ( 1 ) - (1) Conduit Kit; 1/2" EMT
I I I , Meter; FORM 2S
COOPER # B Line Meter Socket 011( 1) Voc = 370 VDC
•
BOND (N) #6 GEC TO (E) UFER AT I Meter Socket; 125A, 4- 14AWG, Ring Type Vmp = 295 VDC
PANEL WITH IRREVERSIBLE CRIMP i LOCATED IN GARAGE NEXT TO INVERTER • Isc = 16.8 ADC • PER ART. 250.64(C) t (i) AWG #6, Solid Bare Copper GEC Imp = 15.6 ADC
CONFIDENTIAL - THE INFORMATION HEREIN ,p8 NUMBER J B-972408 0 0 PREMISE OWNER A111 TIGARD, OR DESCRIPTION: DESIGN: ` I i ►1i i
CONTAINED SHALL NOT BE USED FOR THE FRISIRAS, CHRIS FRISIRAS RESIDENCE TA :s ' , �,'
r OF NO OR E SHALLLL IT ED I OLE IN I '' MODULES: 2 14055 SW 116TH TERR 4.6 KW ROOF MOUNT PV SYSTEM T�� solaity
PART TO OTHERS OUTSIDE THE RECIPIENT'S RESI (20) YINGLI # YL230P -29b
ORGANIZATION, EXCEPT IN CONNECTION WITH PROECT MANAGER MOUNTING SYSTEM: ' TIGARD, OR 97224
:iii Clearview Way
THE SALE AND USE OF NE RESPECTIVE SOLARCITY CANOPY -C W/ EXTENDERS
SOLARCITY EQUIPMENT, IM1HOUT THE WRITTEN PAGE NAME SHEET: REV: DATE San Mateo, CA 94402
PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: T:(650) 638 -10:(650) 638 -102
_EASE (1) FRONIUS # IG 4000 5039682730 SINGLE LINE PV 5 4/19/2o11 (888)- sa-C11 (765-2489) F I www .solar2,9 ty.com
..
1. Conductor Sizing per Art 690.8(B)(1) . • •• • •
a. Conductor must have 30 deg. C ampacity >= 125% of continuous ELECTRICAL CALCULATIONt' :: • • • '.• •• •
. . •
current per Art 215.2(A)(1).
Module: 20 Inv Pwr W PTC StrLen Voltage Drop Calculations Version 5_7.5
b. Conductor must have (after corrections for conditions of use) >= Inverter 1: 1 , :s j 10 Vdrop = (Imp) * (2 * Ljngtlyt * jResistance)• / ( ip) ..
Module: Imp (A) apt. tength.(ft: leWite • : :
continuous current per Table 310.16. Inverter2: String: 7.8 : • 50: : AWG 1C • �a IV ikve Hi: 90 deg F
Module: Vdrop = (7.80 A * iii ft • * 0.0012$ Ohms / 260 V = 0.37%
c. Evaluate conductor temperature at terminations per 110.14(C). Inverter 3: Branch: I 15.6 I 40 1C AWG 101 at Max Ave Hi: 90 deg F
Ampacity of wire derated for conditions of termination must be Module: Vdrop = (15.60 A * 80 ft * 0.00124 Otgns)./. 264V = 0.59%
>= continuous current *1.25. All string terminations are rated at Imerter4: Jatarlprtagedrop •in12l:coQd4tols= 10.97 %I
90' C. Inverter: I 16.67 I 10 : :.•IC G!1d a=24V
Total: modules Total Inv Pwr PTC Vdrop = (16.67 A * 20 ft! _,0d1$ C me) 4 • 2ete V 0.17%
2. OCP Sizing per Art 690.8(8)(1) Photovoltaic Module Electrical Specifications: Total STC Combined) 16.67 I 0 IC AWG 1C1 at 240V
Voc= _ V deg F deg C Vdrop = (16.67 A * 0 it * 0.00120 Ohms) / 240 V 0.00%
a. Round up to next size per Art 240.4(B) Vmp= i 2 V Record Low Temp: 23 Total wltage drop in AC conductors = 0.17%
Isc= i A Max Average Hi Temp: 896 Total wltage drop in AC and DC conductors = 1.13%
3. Conductor Sizing per Art 690.8(B)(1) Imp= p 7 A Record Hi Temp: 106
a. Conductor must have 30 deg. C ampacity >= 125% of continuous Twc= -0.1 V /deg C
current per Art 215.2(A)(1). Tisc= mA /deg C I
String Type A and 2 Combined Strings Type A Voc Correction Method: ` Branch Circuit Type A 10 modules per series string
Fronius IG4000 2 strings per branch 1 -way wire length: 40.ft
b. Conductor must have (after corrections for conditions of use) >= 1D Yingli Y -29b., Inverter Min Vdc Input: Vdc
continuous current per Table 310.16. voc= 3 V Min Vmp at Max Temp: Vdc Voc= V
Vmp= i, 2 V Max Voc at Min Temp: Vdc Vmp= V
c. Evaluate conductor temperature at terminations per Art 110.14(C). Isc= 8 A Inverter Max Vdc Input: Vdc Ilse= A
Ampacity of wire derated for conditions of termination must be Imp= A Max String Size: Imp= A
>= continuous current *1.25. All branch terminations are rated at lcont= A Art 690.8(A)(1) 1 -way wire length: - < "a ft Icons= A Art 690.8(A)(1)
75' C min. 1.a Try USE- 2/RHW -2 at 90 deg C: Table 310.16 3.a Try 11-IWN-2/USE-2 at 90 deg C: Table 310.16
Icont * 1.25 = (Amps)
4. OCP Sizing Icons * 1 = (Amps) 30 deg C ampacity = ' -- I
30 deg C ampacity = I 3.b Icont= (Amps) .. 21.00
a. Round up to next size per Art 240.4(B) 1.b lcont= (Amps) 1 Start ampacity 40
Start ampacity 1 4 Temp. derate ( % =F) 0.58
5. Conductor Sizing per Art 690.8(B)(1) Temperature derate ( % =F) 0.58 Cndt. fill derate ( %_ #) = 1
a. Conductor must have 30 deg. C ampacity >= 125% of continuous Conduit fill derate ( % = #) 1 Derated ampacity MIL 23.2 I
current per Art 215.2(A)(1). Derated ampacity ibiliaill I Term 1 Term 2
Temp table
1.c Icont *1.25= (Amps) 3.c Icont*1.25= (Amps) 26.25 26.25
b. Conductor must have (after corrections for conditions of use) >= Ampacity Ampacity 35 35
continuous current per Table 310.16.
I I
c. Evaluate conductor temperature at terminations per Art 110.14(C). 2 Icont * 1.25 = (Amps) 3.d OCP size =
Ampacity of wire derated for conditions of termination must be OCP size = Combined Inverter Output
>= continuous current *1.25. All inverter output terminations are service Voltage= 240 Volts
rated at 75' C. Inverter Type A Output Total Inverter Power= Watts 1 -way wire length: 0 ft
1 -way wire length: 10 ft Icont = # of inverters *max inverter current Art 690.8(A)(1)
Icons= A Art 690.8(A)(1) Icons = (Amps)
6. OCP Sizing 4 Icons *1.25 = (Amps) A Art 690.8(8)(1) 6 Icons *1.25 = (Amps) A Art 690.8(B)(1)
a. Round up to next size per Art 240.4(B) OCP size = A Art. 240.6(A) OCP size = A Art. 240.6(A)
5.a Try THWN -2 at 90 deg C: Table 310.16 7.a Try THWN -2 at 90 deg C: Table 310.16
7. Conductor Sizing per Art 690.8(B)(1) Icont * 1.25 = (Amps) Icont * 1.25 = (Amps)
a. Conductor must have 30 deg. C ampacity >= 125% of continuous 30 deg C ampacity = I 30 deg C ampacity = 40
5.b Icons= (Amps) 16. 7.b lcont= (Amps) 16.67
current per Art 215.2(A)(1). Start ampacity i Start ampacity ao
Temperature derate ( % =F) 0.91 Temp. derate ( % =F) i 0.91
b. Conductor must have (after corrections for conditions of use) >= Conduit fill derate ( % = #) 1 Cndt. fill derate ( % = #) - 1
continuous current per Table 310.16. Derated ampacity 36.E I Derated am acity 36.4 I
5.c Icont *1.25= (Amps) 0 7.c Icont *1.25= (Amps) , 20.83
c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity Ampacity 35
Ampacity of wire derated for conditions of termination must be I I
>= continuous current *1.25. All inverter output terminations are
rated at 75' C min.
CONFIDENTIAL - THE INFORMATION HERON 48 NUMBER J B-972408 00 PREMISE MER AH,k TIGARD, OR DESCRIPTION: DESIGN: , 014
CONTAINED SHALL NOT BE USED FOR THE FRISIRAS, CHRIS FRISIRAS RESIDENCE TA 6 :: �� .
BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES 14055 SW 116TH TERR 4.6 KW ROOF MOUNT PV SYSTE �I, SOlarCity
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST (20) YINGLI # YL230P -29b
PART TO OTHERS OUTSIDE THE RECIPIENTS
ORGANIZATION, EXCEPT IN CONNECTION WITH PRQECT MANAGER MOUNTING SYSTEM: TIGARD, OR 97224
THE SALE AND USE OF NE RESPECTIVE SOLARCITY CANOPY -C W/ EXTENDERS �/ 3055 Teo Way
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE INVITER: PAGE NAME SHEET: REV: DATE: San Mateo, , CA CA 94402 T:(650) PERMISSION OF SOLARCITY INC. _EASE (1) FRONIUS # IC 4000 5039682730 ELECTRICAL CA PV 6 4/19/2011 ( 888) SOT- CITY (7662489) (1650 . olaraty.com
• • • ••
• LABELS :.•
• • PV MODULE •
WARNING! ELECTRIC SHOCK HAZARD!
( =:,,�..,,, • • •
oecaenw MOM SOM. - • • • • • • • • •• • ont
AtAxuruLl nq KM orrrM • • • • • � • •
aaa V
• • • • • • • • • •
• SalarCit w _ YINGLI 230W MODULE (YL230?'-29b) -•• •••
y ° :c
PHOTOVOLTAIC DISCONNECT ELECTRICAL PARAMETERS I -V CUVES
WARNING! ELECTRIC SHOCK HAZARD! • - . • • • • •
YIN SOLAR Electrical parameters at STC(1000 VW, 25 AM 1.5G according to gb90 4y • • • •Q1.«`• - •
OPERATING VOLTAGE V • • • • • • •
fiAl • •�� --
. (2) MAXIMUM OPER Power Yonr Life
ATING • • A o
YINGLI 230W MODULE Power teleran. teleran. I %I • • 0113•• —V
CURRENT
�
tv Mehl. eftlekay I %1 14.1 a
Sola sty. /seel sa. 'cn rT. Vatteg. at Par s, V,,. IVI 29.: 1 [ Va ape
wrwLan Ar OUR COMPANY °
— IOOOwhn' — 600WA«' — 200W/m -- '
OLTAIC DC DISCONNECT Yingli Solar is a vertically integrated manufacturer Oee• nwt•v_ Evi 37.0 — 60ow/nr — loowhiY
WARNING! ELECTRIC SHOCK HAZARD! of solar photovoltaic modules. Under one roof we Sheri-ca. cornet I IA1 e.40
- _ -._. _. 39.0In
(3) v manufacture our ingots, wafers, cells and modules. Me,,,tn,,�n•te (VI uu600voc:lEC:L000\DC z0" v„,,, V 37.2«,
Eat A This ensures that we can tightly control our material Mar. series lose rat'. IA1 15
Imp A and production quality, offering our customers leading
product durability and sustainable performance backed THERMAL PARAMETERS
.. SolarCitY ..0.A LKAAart.CON by our 25 year limited power warranty',
NOCT (tte•i•al ope atue CM Ise rernaru 1 °51 46.1-2
PERFORMANCE Tomeeratare eaalNeieet.ftrr ..h •
rrt Irr.rnetI,, [ %/ °CI 0.06 ./- 0.01 s
Solar Disconnect » High efficiency, multicrystalline solar cells with high T...r.fem a.tTa.e 4Yart..wp V. (y.Jee 0.3 -0 Grou dhoks a A s
: -eat k
n ma nt• FUrEII P t% / °51 0.45. S' a N
transmission and textured glass deliver a module wat •ne.. pT / -o.os 8 �
(4) series efficiency of upto14.1 %, minimizing installa- TerlperwreeedflehrtoftheWPM..V.. I %I -0.n./ -0.02 e a
WAR NING - Elecln ock Hazard tion costs and maximizi the kWh output of your Tenearetm enfhsiat of IN Woman [w1 °C1 -0.05 al -0.01 Maun!in! side
DO NOT TO iERMINALS system per unit area. , 4 -032x616 in fir—is
Terminals on b Band Load sides l MECHANICAL PARAMETERS Orange holes f- !
may be e ner , ed m the Open Position » Power tolerance of +/ -3% minimizing PV system NYa c 8-0016 i1 F A ' A
mismatch losses. DI..s(elgti/will/dachaslel) 65.0/39.0/2.0 ,I r i , ••
s-1 =A
Tinniness wit leaven Ms Del 2.0
QUALITY & RELIABILITY NeyYt('1 4 3T ; _____ 05 In
DC Disconnect » Robust, corrosion resistant aluminium frame inde-
w<www. — pendently tested to withstand wind loads of 50 psf J..l.. l.a Or.t.ei ntrN /nmw du.YN1 P6s
M "
Judi. Nx eineedens ONO /el. /tYletaess lisp , _ 6.0/4.8/1.0 y ■
ensuring a stable mechanical life for your modules. t
PnIU.e USE pale (Nets IYl /ANSI 47.2, 12 .t
WARNING - Electric ,. lock Hazard » Take confidence in our modules with a 5 year isms- c ' i t
5 DO NOT TO H ERMINALS Mpnk. USE•2 ea.( 4TT /12
ted product warranty and a 25 year limited power 1
Terminals on b c and Load sides I
in
may be ere Jed m the Open Position warranty. PYI cnucto Oype/ peddle. dy tlPEAbtanre and self-locking / 11'65 » Modules protected by box during transportation and Fred LNp(mstr rl /ulLYaealanll repDeredvlass.3zmnt ' s _ 1
with 20 modules in a box on -site waste is minimized. Cell OC VOLTAGE la ALWAYS PRESE MT WHEN tyre (peeuty / leranly. / Wed /wi [i.0 so i PdyLr2stauhw i 6.w a 61a 1 T'�IR
SOLAR MODULES APE EXPOSED TO SUNLIGHT "fir
» Modules Independently tested to ensure compliance rnp. t.MM•I st anodised aluminum alloy /Silver SECTION A —
with certification and regulatory standards. - - --
(6) » Manufacturin faclllt certified to 1509001 qualit OPERATING CONDITIONS WARNING -Dual Power Sources
9 Y y
Second source Is photovoltaic system Management System standards. yeresat t.ne.retan [•e1 - 40towt Solar modules are electrical generating
M.a. rd. 1Na [retl so
',WARNING n equipment, and should only be handled or ins
- Electi ShOCk Hazer , WARRANTIES
No user avrvinoabw pans muae if
7 N M.. sees 1.4 [ESn m Called by professional installers. Read the in
struction manual in its entirety before hand-
( ) Contact authorized servieer for asalatance °' \ \� s -year limited product warranty• ling, installing, and operating Yingli modules.
I Limited power warranty.: 10 years at 90% of the minimum rated
CAUTION \ power out put, 25 years at 80% of the minimum rated power output z PACKAGING
- (8)
QUALIFICATIONS Et u NanYrdnvlaNPnWYtON zo
IEC612t5, IEC61730, UL1703, Class C Fire Rating, 1509001 ` Bu sire 0.0 /win ► / dglY [fill
PV COMBINER BOX "'TN a
A Bex midst [Ilsl li
(a/ WARNING: �"e C �� US u � E w R � � J Yingli Green Energy Americas, Inc.
. ELECTRIC SHOCK HAZARD •In compliance .al• our warranty Terms and Conditions ', ft."
� usatSyingll solaccom
Tel: .1 (888) 686 -8820
( WARNING Included specafictima Ineded In lCO dataaheet are eae, I ..
3 and serve only lor comparisons d different module types
ELECT SHOCK HAZARD IF A GROUND specifications arc sublecr to change without noti ce. YINGLI O
SLAR
FAULT IS INDICATED.THE NORMALLY
GROUNDED CONDUCTORS MAY BE ENER
GIZED AND UNGROUNDED www.yinglisolar.com
www.yingllsolaccom Peat Ee.g we
WARNING
"
11 J INVERTER OUTPUT CONNECTION
DO NOT RELOCATE
THIS OVER CURRENT DEVICE
CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J B-972408 00 PREMISE OWNER: AHJ: TIGARD, OR DESCRIPTION: DESIGN: ` Ib bile '
CONTAINED SHALL NOT BE USED FOR THE FRISIRAS, CHRIS FRISIRAS RESIDENCE TA w
� a :
NOR BENEFIT
SHALL WHOLE OF ANYONE EXCEPT SOLAR INC., MARKET: MODULES:
14055 SW 116TH TERR 4.6 KW ROOF MOUNT PV SYSTEM ' I ' So I arC ty
NOR SHALL IT BE DISCLOSED IN OR IN REST (20) YINGLI # YL230P -29b
PART A IZ TO O OUTSIDE THE RECIPIENT'S PROJECT MANAGER: MOUNTING SYSTEM: TIGARD, OR 97224 �
ORGANIZATION, EXCEPT IN CONNECTION WITH 1 / Ii 3055 Clearview Way
THE SALE AND USE OF THE RESPECTIVE SOLARCITY CANOPY -C W/ EXTENDERS
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Mateo, CA 94402
PERMISSION OF SOLARCITY INC. PAYMENT TYPE INSERTR: 5039682730 Pv 7 4/19/2011 T:(650)638 -1028 I F:(650) 638 -1029
EASE (1) FRONIUS # IG 4000 CUTSHEETS (888)- SOL- CITY(765 -2489) I www.solarcity.com
• • • . ••
• • .. • • • •
. .. :.•
•
INVERTER ' • • • •
• •
. • • . • • • •
•• • •••• • •
• • • • • • : ••• •••
• •
•
FRONIUS IG
•• .5 • . FRONIUS IG 4000 / 5100 / 4500 -LV - Specifications • • ' • : :.. '
• .
. • . • .•. ....... •
• • . • •
S S
DC Input Data FROMM IG 4000 FROMUS IG 5100 FRONDS 4500 -W
Recommended PV power 3000 - 5000 Wp 4000 - 6300 Wp 3600 - 5500 Wp
Max. DC input voltage 500 V 500 V 500 V
Operating DC voltage range 150 - 450 V 150 - 450 V 150 - 450 V
Max. usable DC Input current 26.1 A 332 A 29.3 A
AC Output Data FRONIUS IG 4500 -LV
Maximum output power 040° C 4000 W I 51 W 4500 W
Nominal AC output voltage 240 V 208 V
Utility AC voltage range 212 - 264 V (240 V +10%/ -12%) 183 - 227 V
Maximum AC current 16.7 A 21.3 A 21.6 A
Maximum utility back feed eugri It 0.0 A I 0.0 A 0.0 A
Operating frequency rage 59.3 - 60.5 Hz (60 Hz nom)
Total harmonic distortion < 5 %
Pow Factor (cos ph) 1 S
Goners! Data IG 4000 _ FROMUS JO 8100 I FROMUS tai 45OOd1f
Max. efficiency 95.2 % 95.2 % 94.4 %
Consumption in stand -by _ - < 0.1 W (night)
Consumption during operation 15 W
Enclosure NEMA 3R if
Size (Ixwxh) 28.4x16.5x (720 x 418 x 223 mm) -
Weight 42 lbs. (19 kg) i
Ambient temperature range -5 to 122 °F ( -20 to +50 °C) `s
Cooing controlled forced ventilation
Integrated DC and AC disconnects standard UL approved DC & AC disconnects
Protections AM111101111111.11.1i g
Ground fault protection Internal GFDI, in accordance with UL 1741
DC reverse polarity protection Internal diode 5 .
Islanding protection Internal. in accordance with UL 1741, IEEE 1547 $
Over temperature Output power derating 1J
Surge Protection Internal DC & AC protection, Tested to 6 kV "
Com • nee -
Safety UL 1741 t 1
EMI - - - FCC Part 15; Class A & $ g g
Anti- (standing protection UL 1741, IEEE 1547 g
Ground fault detector and interrupter Compliant with NEC Art. 690 requirements, UL 1741 ri 1
Miscellaneous -
Maximum AC over current protection Two-pole, 30 A circuit Weaker th — z i
AC wire sizing Use maximum AWG 8194 °F (90 °C) copper wire E. %
DC wire sizing Use maximum AWG 6194 °F (90 °C) copper wire ; 1
AC disconnect 32 A - — A'?
DC disconnect 40 A e
. Es
Wanamy - 10 year Premium Warranty is Standard
�
3=
Distributed by i—ir7r7iL15 X =
le
l E
Fronius USA LLC n i
Solar Electronic Division
:7
• 10421 Citation Drive
Suite 1100 Brighton, Mi 48116
Phone: 810- 220 -4414
Fax: 810-220-4424
E -Mail: pv- ustifronius.com e
www.fronius- usa.com
. 01,.......■•••■■ Th
CONFIDENTIAL - THE INFORMATION HERON JOB NUMBER J B -9 7 2 4 0 8 00 FREUISE OWNER AHJ: TIGARD, OR DESCRPTICN: DESIGN: ` %bid
CONTAINED SHALL NOT BE USED FOR THE FRISIRAS, CHRIS FRISIRAS RESIDENCE TA :';,,,
BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES I � � � So l a CC i
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (20) YINGLI # YL230P -29b 14055 SW 116TH TERR 4.6 KW ROOF MOUNT PV SYSTEM
PART TO OTHERS OUTSIDE THE RECIPIENTS
ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM: TIGARD, OR 97224 m
THE SALE AND USE OF THE RESPECTIVE SOLARCITY CANOPY —C W/ EXTENDERS �� 3055 Clea vewWay
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE San Mateo, CA 94402
PERMISSION OF SOLARCITY INC. PAYMENT TYPE INVERTER: 5039682730 19 T:(650) 638 -1028 I F:(650) 638 -1029
LEASE (1) FRONIUS # IG 4000 50396 2011 CUTSHEETS PV 8 / / (BBB)- NOL- CITY(765 -2489) I enovsolarcity.com
• ••
1 • ••_ _ •:$
•• •• ' •• • ••
••. • . . . • • •
••• • •• •• S. •
. -
• •
• • • • • • • • •• •• •
• MOUNTING HARDWARE ••.••• • •
• •
• • • • • S .:....
•• ••
• • . • • • • ..••.S••
i iiiii—iiiimit �� \ _� APPROVED INSTALLATION METHOD • ••• • • ••
���_
• Roots (brackets) are to be mounted no further
RESIDENTIAL SOLAR MOUNTING SYSTEM than Wapart.
• Rafters must be located. Pilot holes must be drilled into I F- <I
Canopy is the strong, safe, waterproof mounting system for structurally attaching the center of rafters 1 28 1 2.5
solar panels to composition shingle and wood shake roofs. A715 grade 50 high • Shingle course immediately above penetration shall be cut 2 33 1 3
strength structural steel with durable corrosion resistant coating provides more using provided template to accommodate flashing. 3 43 2 2.5
strength than aluminum and better corrosion resistance than stainless steel. Bracket- • Local wind conditions, exposure, roof angle, and position 4 50 2 3
style attachment allows for shingle flashings to completely cover penetrations, of array on roof will determine design wind pressure.
This dud assumes 15 sq. n. or fewer per panel
providing excellent long -term waterproofing. Standard installation of Canopy applies when design wind and minima 1.5 penetrations p. r panel. neee
pressures are found to be 28psf or lower and requires one •PAr values to be calculated according to ASCE 7-05.
21/2-inch lag bolt in the primary position. For all other cases.
• Precision engineered bracket geometry provides stiffest see chart to right.
uplift resistance of any moulting bracket. Rated to 500 IDs. • _.-----1 • Flashing is to be inserted under course of shingles above
• A715 grade 50 high strength structural steel provides --- penetration and pressed down over root until it snaps
more strength than aluminum. - \ into place.
• Proven /5 year corrosion resistant hot -dip galvanized .o f.---- • Rail is attached with rail locking clamp. . ��
-1
coating. Laboratory tests shcw canopy has better corrosion
•
resistance than common stainless steel,
• Shingle -style flashing completely covers penetration, providing G Flashing
better long term leak protection than neoprene cone flashings. • . ei 2 Lags and Washers
! 3: Root - Bracket • ' 1
rf
• Shingle Flashing locks in place for best water proofing ,
4' Root - Bracket i
5 I. t
• 2x 5/16 lag bolts �. 5 - Flashing installed / i - � ' = 7 i ..a
• 2x 5/16 flat washer u, • j I Rail installed ' - ma - y �� --
--- rj
_
• Canopy root precision engineered mounting bracket R� ! ` �� .- ...�. .- .S �o sr�
r: L___-- 8 " OC M ax \ . - . -
� � !i��
• Roof rafter 10 :- -- -+ - - -.. ..- -- - --° -- • -
• Rail 1��; s " �.
11
4" IarCiiy
� 888 -SQL -CITY I 888-765-2489 I WWW.SOLARCITY.COM
CONFIDENTIAL - NE INFORMATION HEREIN JOB NUMBER: J B -9 72408 0 0 PREMISE OWNER: AIIJ TIGARD, OR DESCRIPTION: DESIGN: ` bki4 '
CONTAINED SHALL NOT BE USED FOR THE FRISIRAS, CHRIS FRISIRAS RESIDENCE TA 44.1:ir,,�� B •
N OF ANYONE N WHOLE INC., yAEL MODULES:
NOR OR SHALL IT T BE � DI DISCLOSCLOS ED D IN WHOLE LE RESI IN ESI (20) 20) YINGLI # YL230P -29b 14055 SW 116TH TERR 4.6 KW ROOF MOUNT PV SYSTEM ,,,' ouncil
PART TO OTHERS OUTSIDE THE RECIPIENTS MET MANAGER MO(I(Tp(G m ly; TIGARD, OR 97224 �
ORGANIZATION, EXCEPT IN CONNECTION WITH f : './ 3055 Clearview Way
THE SALE AND USE OF THE RESPECTIVE SOLARCITY CANOPY -C W/ EXTENDERS
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV DATE: San Mateo, CA 94402
INVE
PERMISSION OF SOLARCITY INC. PA YMEN T TYPE RTQt 5039682730 4 rt 011 T:(650) 638 -1028 I F:(650) 638 -1029
LEASE (1) FRONIUS # IG 4000 CUTSHEETS PV 9 19 /L (888) - SQL- CITY (765 -2489) I www.solarcity.com
• • • • • • •••
• • • •• •• • • • •
• oo
••• • •• • •• • • • • •
• • • ••
• • • • • • • • • •
• • •
SPANNING VENTS • • • . ; •• • •• •
•. • •
••••'' : :••' •
• • • •• • ••• •••
• •
SPANNING PHOTOVOLTAIC MODULES OVER VENTS
• •' •
MINIMUM VENT HEIGHT IS 6 "ABOVE THE SURFACE OF THE ROOF PER 2010 CPC SECTION 906.1 . :• •:• ••• ,, .• ••
. ••• r• ' :
- 2010 CPC SECTION 311.5 STATES NO FITTING, FIXTURE, AND PIPING CONNECTION, APPLIANCE, : DIAMETER • • • • 2''MIN CLEAR SPAN
DEVICE, OR METHOD OF INSTALLATION THAT OBSTRUCTS OR RETARDS THE FLOW OF WATER, VENT SPANNING DETAIL TO UNDERSIDE
• WASTES, SEWAGE, OR AIR IN THE DRAINAGE OR VENTING SYSTEMS, IN AN AMOUNT GREATER OF MODULE
• THAN THE NORMAL FRICTIONAL RESISTANCE TO FLOW, SHALL BE USED UNLESS IT IS INDICATED SCALE: 1 1/2 " =1' -
AS ACCEPTABLE IN THIS CODE OR IS APPROVED PER SECTION 301.1 OF THIS CODE. THE 0 , —
ENLARGEMENT OF A THREE (3) INCH (80MM) CLOSET BEND OR STUB TO FOUR (4) INCHES
(100MM) SHALL NOT BE CONSIDERED AN OBSTRUCTION ". FROM THIS SECTION, IT IS CLEAR THAT % 6
MOUNTING SOLAR MODULES OVER A VENT IN A MANNER THAT WILL NOT HAVE A GREATER SOLAR PANEL / VENT HEIGHT
FRICTIONAL RESISTANCE TO AIR FLOW WOULD BE ACCEPTABLE. ATTACHED WITH MODULE FROM TOP OF
CLAMPS
EQUATIONS: �� ___.111kROOFIN MATERIAL
THE FRICTIONAL RESISTANCE TO FLOW IS DIRECTLY PROPORTIONAL TO THE AREA THAT THE AIR SOLARCITY SOLAR RAIL /�
CAN FLOW THROUGH. IN THE VENT, THAT IS THE CROSS — SECTIONAL AREA OF THE VENT PIPE: Y //
SOLAR MODULE \ Avent = 7r*R STANDOFF BRACKET
AND POST \•
WHEN THE AIR EXITS THE VENT, THE AREA IT HAS TO FLOW THROUGH IS THE CIRCUMFERENCE OF /
THE VENT TIMES THE VERTICAL DISTANCE BETWEEN THE VENT AND THE MODULE ABOVE (IN THIS ROOFING MATERIAL /
CASE, WE ARE LEAVING THE DIAMETER BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF
THE PANEL). THIS METHODOLOGY ASSUMES THE WORST —CASE SCENARIO OF MOUNTING THE PLYWOOD '+I VENT PIPE
MODULES HORIZONTALLY OVER THE VENT. IN ACTUALITY, THE MODULES WILL BE TILTED WHICH (E) RAFTER
WILL OFFER MORE AREA FOR AIR TO FLOW THROUGH.
Agap = C *CLEARANCE = (7r*D) *D LAG BOLT
Agap = (71**2 *R) *(2 *R)
Agap = 4 *7r*R
4 *7r*R > 7r*R2 NOTE : SOLAR MODULE ATTACHED TO ROOF BY
STANDOFFS SIZED TO CREATE APPROPRIATE CLEARANCE
FROM THE EQUATIONS ABOVE, IT IS EVIDENT THAT MOUNTING THE MODULES IN THIS MANNER DETERMINED TO THE LEFT
ALLOWS FOUR TIMES THE AMOUNT OF AIR FLOW ABOVE THE VENT THAN IN THE VENT ITSELF.
VENT HEIGHT WILL BE A MINIMUM OF 6 INCHES ABOVE THE ROOF, OR THE MINIMUM VALUE
ALLOWED BY LOCAL BUILDING CODE.
MINIMUM CLEARANCE BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF THE SOLAR MODULE
GLASS SHALL BE AT LEAST THE DIAMETER OF THE VENT.
IN THE DIRECTION OF THE SLOPE OF THE ROOF, THERE SHALL BE A GAP OF AT LEAST 1/2 INCH
BETWEEN MODULES.
THE ROOF SLOPE MUST HAVE A MINIMUM INCLINATION OF 10' OR THE PANELS MUST BE SLOPED
AT A MINIMUM INCLINATION OF 10'.
CONFIDENTIAL — THE INFORNATION HEREIN JOB NUMBER J B-972408 00 PREMISE OWNER AH..k TIGARD, OR DESCRIPTION: DESIGN: ` 064
CONTAINED SHALL NOT BE USED FOR THE FRISIRAS, CHRIS FRISIRAS RESIDENCE TA : ; ,: -
�� T OF ANYONE EXCEPT SOLARCITY INC., yA : MODULES: 14055 SW 116TH TERR 4.6 KW ROOF MOUNT PV SYSTEM
�I, S��a
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST (20) YINGLI # YL230P -29b
NOR S
PART TO OTHERS OUTSIDE THE RECIPIENT
ORGANIZATION, EXCCEPT T IN CONNECTION WITH S PROJECT MANAGER MOUNTING SYSTEM: TIGARD, OR 97224
THE SALE AND USE OF THE RESPECTIVE SOLARCITY CANOPY —C W/ EXTENDERS � // 3055 Clearview Way
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Mateo, CA 94402
aSSION OF SOLARCITY INC. PV 10 4/19 2011 LE ASE TYPE: WIRIER:
FRONIUS # IC 4000 5039682730 VENT SPAN DETAIL 7:(650)638-1028 I F:0)
(65638 - 1029
/ (888)- SOL {IfY (765 -24 www .solarcity.com
•
.1k CITY • F TIGA "D
Building Division
13125 SW Hall Blvd.
Tigard, OR 97223
503.639.4171
www.tigard- or.gov
I L
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof - Mounted
PhotoVoltaic Solar Panel System
Installation address: /4056 5I V 11 ( 0 444. �e ,/
City: T 9 GGl'C� Zip 8722
Owners name. Fr Slra --
Contractors name: cio %r (l p 7 0190ra /On'
Contractors CCB number: /sr� qr
[�+!!.'�i • � .. ASV L'f L� �9� l kJ�iY � 1t k i b XY[ i rr
If "Yes ", does not
qualify for the
Flood Hazard Area Is the installation ❑ Yes prescriptive path,
located in a flood No follow OSSC or
plain/ flood way
ORSC for design
/ requirements.
r�
Wind Exposure Is the wind Yes If "Yes ", qualifies for
exposure "C" or less No the prescriptive
path.
Installations on Is the Ground Snow If "Yes ", qualifies for
detached single/ Load 70 psf or less. the prescriptive
two - family dwelling / Yes path.
Ground Snow single/ two - family
Load townhomes and /or ❑ No
their accessory
structures.
Installations on all Is the Ground Snow If "Yes ", qualifies for
structures other Load 50 psf or less. the prescriptive
than above /Yes path.
❑ No
Is the construction j
material wood and dyes If "Yes ", qualifies for •
does the
Type of constructions qualify ❑ No the prescriptive
Construction as "conventional
path.
light frame"
construction?
Is the spacing 24 If "Yes ", qualifies for
Pre - engineered inches or less. the prescriptive
trusses. Li Yes path.
Roof framing ❑ No
members Is the spacing 24 If "Yes ", qualifies for
Nominal lumber inches or less. the prescriptive
'Yes path.
❑ / No
d
Is the combined Yes If "Yes ", qualifies for
weight of the PV the prescriptive
modules and ❑ No path.
racking less than or
Solar installation equal to 4.5 psf.
Is the solar
installation layout in /Yes If "Yes ", qualifies for
accordance with the prescriptive
Section 305.4(3) of ❑ No path.
the 2010 Oregon
Solar Code.
❑ Metal
Check the type of ❑ Single layer of If roofing material is
roofing material. wood shingle/ shake one of the three
/Max. Two layers types checked,
Roofing material qualifies for the
of composition prescriptive path.
shingle.
Is the roof mounted e(Yes If "Yes ", qualifies for
Connections of the solar assembl ° No the prescriptive
solar assembly to connected to roof path.
the roof framing or blocking
directly.
Attachment of roof Is the gauge 26 or ❑ Yes If "Yes ", qualifies for
mounted solar less? the prescriptive
systems directly to ° No path.
standing seam i 1 j)k
metal panels
Page 2 of 4
•
115 lbs for 60 inch If "Yes ", qualifies for
Minimum Uplift spacing or less the prescriptive
rating of Clamps: CI Yes path.
❑ No
75 lbs for 48 inches If "Yes ", qualifies for
spacing or less the prescriptive
❑ Yes path.
❑ No
If the spacing falls
Spacing of clamps? Minimum 24 inches within 24 inches and
V1( 60 inches, qualifies
in Maximum 60 inches for the prescriptive
path.
If the width of the
Width of roofing 18 inches or less panel is less than
panels? 18 inches, qualifies
for the prescriptive
in path.
o Yes
Size and spacing of Minimum #10 at 24 o No
fastener? inches o/c If "Yes ", qualifies for
the prescriptive
path.
Is the roof decking ❑ Yes If "Yes ", qualifies for
of WSP min. 1/2" ❑ No the prescriptive
thickness, decking path.
connected to
framing members w/
min. 8d nails @
6 "/12" o /c.
Maximum 18 inches Is the height less If "Yes ", qualifies for
Height of the solar from the top of the than or equal to 18 the prescriptive
modules module to the roof inches path.
surface IYes
❑ No
Page 3 of 4
x�n
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read,
Minimum size of the plan is 8.5x11 inches.
Attach a simple structural plan showing the roof framing (rafter size, type,
and spacing) and PV module system racking attachment.
Structural System must be shown in sufficient detail and clarity to assess whether it
Plan meets the prescriptive construction requirements as listed earlier above in
the matrix.
Minimum size of the plan is 8.5x11 inches.
PN Modules
* Manufacturer:
* Model Number: w. 30 P - 2 q
* Listing Agency: (AL /703
Page 4 of 4