Loading...
Plans BUP2o - oc . g ld`t co, sv✓ l 2157 /4v COLUMBIA 28395 S.W. Boberg Road, Suite B Wilsonville, OR 97070 -6769 (503) 684 -9123 RooFING AND SHEET NETAL. FAX: ) 68 www.rero -1458 m r 2 Zo , G In - r'/ t\t G-, e ■ Get.. C NH 1o900 5.) /z / Ave", — r/6"44-0, c9/ iV 57 Z& EXPERT SOLUTIONS, GUARANTEED RESULTS \ \ OREGON CCB: 116607 WASHINGTON L & I: CCCDCG COLUMCS038RW CALIFORNIA CLSB: C39 769329 HIC 2001 ROOFING MATERIALS & SYSTEMS DIRECTORY < . 172 ROOF COVERING MATERIALS (TEVT) ROOF COVERING MATERIALS (TEVT) Roofing Systems (TGFU)— Continued Roofing Systems (TGFU)— Continued Surfacing (Optional): #11 ceramic coated roof granules, applied at 50 Surfacing One application of "Gacoflex A -55 Series" (various colors), lbs /sq. applied at 1 -1/2 gal /sq. (15 dry mils). 23. Deck: NC Incline: 2 35. Deck: NC Incline: 1/4 Foam: SWD Urethane Co. "SWD 525b ", 1 in. min. Foam: "Polyfoam 251 ", " Polyfoam 275" or "Polyfoam 303 ", any thick - Base Coat: One or two applications "Gacoflex Ure -Cap 6800" Series, ness. applied at 1 -1/4 gal /sq /application (14-28 dry mils). Base Coat: "Gacoflex UB -64," applied at 1 -1/2 gal /sq. (18 dry mils). Top Coat "Gacoflex Ure-Cap 6800" Series, at 1 -1/4 gal/ sq. (14 dry Trowel Coat: 30/60 mesh crushed walnut shells mixed at a rate of 5 mils). lb /gal with "Gacoflex UB -64," applied at 1 -1/2 gal /sq or "Gacoflex Surfacing (Optional): #11 ceramic coated roof granules, applied at 50 applied at 1 -1/2 gal /sq (18 dry mils) followed by the broadcast Ib /sq (12 dry mils). application of 30/60 mesh crushed walnut shells applied at 7-8 lb/sq. 24. Deck: NC Incline: 1/4 Surfacing: "Gacoflex U -66 ", applied at 1/2 gal /sq. (6 dry mils). Foam: " Polyfoam 251" or " Polyfoam 303 ", 1 in. min. 36. Deck: NC Incline: 2 Base Coat One or two applications "Gacoflex LIB -64", applied at 1.2 Foam: "Polyfoam 275 ", any thickness. Primer: "E-54" (not UL Classified), .0.67 gal /sq. gal /sq /application (14-28 dry mils). Base/Top Coat: "U -62 ", 2.0 gal /sq. Surfacing: "Gacoflex U-66 ", applied at 1 gal/ sq. (12 dry mils). Base Coat: "Gacoflex UB -64," applied at 1 -1/2 gal /sq. (18 dry mils). 25. Deck: NC Incline: 1/4 Trowel Coat: 30/60 mesh crushed walnut shells mixed at a rate of 5 Foam: "Polyfoam 251" or "Polyfoam 303", 1 in. min. lb /gal with "Gacoflex UB -64," applied at 1 -1/2 gal /sq or "Gacoflex Base Coat One or two applications "Gacoflex UB- 7050 ", applied at 1 UB -64 ", applied at 1 -1/2 gal/sq (18 dry mils) followed by the broadcast gal /sq /application (16-32 dry mils). application of 30/60 mesh crushed walnut shells applied at 7-8 lb/sq. Surfacing: "Gacoflex UA -65 ", applied at 1 gal/ sq. (12 dry mils). Surfacing: "Gacoflex U-66 ", applied at 1/2 gal /sq. (6 dry mils). 26. Deck: NC Incline: 1 -1/2 37. Deck: NC Incline: 2 Foam: "Polyfoam 251" or "Polyfoam 303 ", 1 in. min. Foam: "Polyfoam 275 ", any thickness. Base Coat: One or two applications "Gacoflex UB- 6499", applied at 1.2 Primer. "E-54" (not UL Classified), 0.67 gal /sq. gal /sq /application (14-28 dry mils). Base /Coat "U -62 ", 1.25 gal /sq. Surfacing: "Gacoflex A- 5500Q", applied at 1-1/2 gal/ sq. (14 dry mils). Base Coat: "U -62," 0.75 gal/sq. 27. Deck: NC Incline: 1/4 Base Coat (optional): "U -62," 0.75 gal /sq. Foam: "Poly -Iso" or "Poly -Iso Special" with "Polyfoam 251" or "Poly- Base Coat "U-62," 0.75 gal /sq. foam 303 ", 1 in. min. Surfacing (optional): walnut chips at 9 to 11 lbs per sq. Top Coat: Two Applications "Ure-Cap 68" Series coating (various GAF MATERIALS CORP R1306 colors), applied at 1 -3/8 gal /sq /application or three applications, 1361 ALPS RD, WAYNE NJ 07470 applied 1 -1/4 gal /sq /application. "Ruberoid 20" or " Ruberoid Modified Base Sheet' may be utilized as an Top Coat (Optional): "Gacoflex UA-65" Series (various colors), applied alternate to Type G2 base sheets in any of the following Classifications. at 1 gal /sq or "Gacoflex UA -60 ", applied at 1 -1/4 gal /sq (12 dry mils). 1/2 in. thick (min) gypsum board or 1/4 in. thick (min) G-P Gypsum 28. Deck: NC Incline: 1/4 Dens - Deck® may be used in any existing noncombustible deck Classification. Foam: "Poly -Iso" or "Poly -Iso Special" with "Polyfoam 251" or "Poly- When this is done, the resulting roofing system is acceptable for use over foam 303 ", 1 in. min. combustible (15/32 in. min) roof decks. The joints in the gypsum board and Base Coat: One or two applications "Gacoflex UB 64 ", 1 gal /sq/ overlayment board are offset 6 in. with the joints in the deck. If polystyrene is application (12 -24 dry mils). part of the roof system, it must be placed below the overlayment board. Surfacing: "Gacoflex UA -65" Series 1 gal /sq or "Gacoflex UA 60 , Also, multiple plies of " GAFGLAS Ply 4" or "Ply 6" may be adhered to G-P Gypsum LAS Stratavent hot asphalt. applied at 1 -1/4 gal /sq (12 dry mils). " GAFGLAS Stratavent Nailable Base Sheet" may be mechanically attached 29. Deck: NC Incline: 1/4 or hot mopped over noncombustible decks and as a recover over existing roof Foam: "Poly -Iso" or "Poly -Iso Special" with " Polyfoam 251" or "Poly- systems. foam 303 ", 1 in. min. GAFGLAS Perlite Insulation may be utilized as a cover board over "EVER - Base Coat: One or two applications "Gacoflex UB- 7050 ", applied at 1 GUARD" insulation in any of the following systems. gal /sq /application or three applications, applied 1 -1/4 gal /sq/ Unless otherwise indicated, the roof insulation is mechanically fastened, application (16-32 dry mils). adhered with hot mopping asphalt or urethane insulation adhesive. Surfacing "Gacoflex UA-65" Series (various colors), applied 1 gal /sq ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT (12 dry mils) Type G2 asphalt glass mat base sheet ("GAFGLAS #75 Base Sheet" or 30. Deck: NC Incline: 1/2 "GAFGLAS #80 Premimum Base Sheet" ) is a suitable alternate for Type G1 Foam: "Poly -lso" or "Poly -Iso Special" with " Polyfoam 251" or "Poly- asphalt A glass or C rroof indicated below4" or' "GAFGLAS Ply 6') in the foam 303 ", 1 in. min. The roof deck may first be covered with a Type G2 asphalt glass mat base Base Coat: One or two applications "Gacoflex UB- 7050 ", applied at 1 sheet "GAFGLAS Stratavent (Vent -Ply) perforated" or " GAFGLAS Stratavent gal /sq /application or three applications, applied 1 -1/4 gal /sq/ (Vent -Ply) for nailable decks ". Perforated to be mopped and nailable to be application (16-32 dry mils). mechanically attached granule side down. Surfacing: "Gacoflex UA -60" Series (various colors), applied 1 gal /sq As an option Type G2 asphalt glass mat base sheet ( "GAFGLAS #75 Base 31. D (15 ) mils Sheet ", " GAFGLAS #80 Premium Base Sheet" or "GAFGLAS Stratavent eck NC Incline: 2 . (Vent -Ply) for nailable decks" ) may be substituted for G1 asphalt glass fiber sheet Foam: "Poly -Iso" or "Poly -Iso Special" with "Polyfoam 251" or "Poly- the following sysstteems Ply 4" or " GAFGLAS Ply 6 ") as the nailed base ply in foam 303 ", 1 in. min. Bottom ply or base sheet may be solid mopped, spot mopped or mechani- Base Coat: "GacoSil S- 1000 ", applied at 1 gal /sq (10 dry mils). cally fastened. Surfacing: "Gacoflex S- 1000", applied at 1 gal /sq (10 dry mils). Unless otherwise indicated, all insulations may be hot mopped or mechani- 32. Deck: NC Incline: 1 cally fastened. Foam: "Polyfoam 251" or "Polyfoam 303 ", any thickness. "GAFGLAS Flashing" or " Ruberoid" may be used for flashing in any of the Surfacing: "Gacoflex Ure - Shield 7007 ", 40 dry mils. Class A, B or C systems listed below. 33. Deck: NC Incline: 2 When "perlite" is referenced, this includes "GAFTEMP PERMALITE®" or Foam: "Polyfoam 275 ", any thickness. any other UL Classified perlite insulation. Base Coat: "Gacoflex A- 6211 ", 1-1/2 gal /sq (14 dry mils). Crushed stone or slag are suitable alternates for gravel in any of the Class A, Surfacing: "Gacoflex A- 6200" series (various colors), 1-1/2 gal /sq (14 B or C systems listed. dry mils). Structural cement fiber building units are considered suitable to be included 34. Deck NC Incline: 2 as a deck in the following Class A, B or C systems listed over C -15/32 or NC. Foam: Polyfoam 251, "Polyfoam 275" or "Polyfoam 303 ", any thickness. The use of gypsum board under any of the following Class A, B or C systems Y Y Y Y does not adversely effect the rating. The use of 1/2 in. min gypsum board is an Base Coat: One or two applications "Gacoflex UB- 7050 ", applied at 1 acceptable alternate for insulation over C -15/32 decks. gal /sq. /application (16-32 dry mils). The use of polystyrene insulation board between min 3/4 in. perlite board LOOK FOR THE UL MARK ON PRODUCT • 180 ROOF COVERING MATERIALS (TEVT) ROOF COVERING MATERIALS (TEVT) Roofing Systems (TGFU)— Continued Roofing Systems (TGFU)— Continued Membrane: "EverGuard TPO Black ". Membrane: "EverGuard SR ", 40-100 mil (TPA). 14. Deck: NC Incline: 1/2 4. Deck: C -15/32 Incline: 1/2 Insulation: "GAFrEMP", wood fiber, glass fiber or perlite any thick- Base Sheet: One or more layers Atlas Roofing "FR50" mechanically ness. fastened. Membrane: "EverGuard TPO White ". Membrane: One layer "EverGuard TPO Black ", " EverGuard TPO 15. Deck: NC Incline: 1 White" or "EverGuard TPO-EX White" mechanically fastened. Insulation: "GAFT'EMP ", wood fiber, glass fiber or perlite any thick - MAINTENANCE AND REPAIR SYSTEMS ness. Unless otherwise indicated, these constructions are intended for installation Membrane: "EverGuard TPO-EX White ". over an existing Class A, B or C system. 16. Deck: C -15/32 Incline: Unlimited Class A Bather Board: 1/4 in. G-P Gypsum Dens - Deck ®, mechanically fas- 1. Deck: C-15/32 Incline: 1 / 2 tened. Existing Roof System: Class A asphalt, glass fiber, felt, smooth surfaced Membrane: EverGuard "TPOSR" or "EGSR ", 40-100 mil, mechanically or gravel surfaced"(gravel may be removed). Covered with: fastened. Base Sheet: Type G2, mechanically fastened or adhered with hot 17. Deck: C-15/32 Incline: 1/2 roofing asphalt. Slipsheet: Two or more layers Atlas Roofing "FR 50 ", mechanically Membrane: "Ruberoid® Torch 1" (modified bitumen), heat fused. fastened. Surfacing: Karnak Chemical "Karnak 'No. 97 Fibrated Aluminum Membrane: "EverGuard EGSR ", 40 -100 mil, mechanically fastened. Asphalt Roof Coating", 1-1/2 gal/ sq or Grundy Industries "al -MB 18. Deck: NC Incline: 3/4 Aluminum Roof Coating", at 1 -1 /2 gal/ sq. Insulation: Hunter Panels "H- Shield ", "H- Shield -WF" or Johns Man- 2. Deck: NC Incline: 1/2 vile "E'NRG'Y 2 ", any thickness. Insulation (Optional): Perlite, glass fiber or wood fiber, 2 in. max. Membrane: "EverGuard TPO", 45-60 mil. Base Sheet: Type 15 asphalt organic felt, Type G2 or "Flex Base 60" 19. Deck: C -15/32 Incline: Unlimited (modified bitumen), mechanically fastened or adhered with hot roofing Insulation (Optional): Atlas Roofing " ACFoam I ", Apache Products asphalt. "Apache White Line" or "Apache Pyrox", Hunter Panels "H- Shield ", Membrane: "Ruberoid® Torch 1" (modified bitunlen), heat fused. "H- Shield -WF" or Johns Manville " E'NRG'Y 2 ", "E'NRG'Y -IIA', Surfacing: Gibson- Homans "Black Jack 5176 Fibered Aluminum Roof ,: "E'NRG'Y -1G" or "Barrier Board Plus ", RhoFlex "Isocyanurate GL, GW Covering" or "PC 401 Fibered Aluminum Roof Coating" at 2 gal /sq. ` .;', or HF ", Rmax "Multi- Max ", any thickness. 3. Deck: NC Incline: 1/4 Barrier Board: 1/2 in. min gypsum board with staggered joints (6 in. Existing Roof System: Class A, B or C covered with offset). Membrane: "Ruberoid® Torch 1" (modified bitumen), heat fused. Membrane: "EverGuard TPO", 45-60 mil. Surfacing Gibson- Homans "Black Jack 5176 Fibered Aluminum Roof Class B - Mechanically Fastened Covering" or "PC 401 Fibered Aluminum Roof Coating" at 2 gal /sq. 1. Deck: C -15/32 Incline: 1-1/2 4. Deck: C -15/32 Incline: 1/2 Gypsum Board (Optional): 1/ 2 in., mechanically fastened. Existing Roof System: Class A asphalt, glass fiber, felt, smooth surfaced Slip Sheet: Atlas Roofing "FR -50", 30 mil miry mechanically fastened. or gravel surfaced (gravel may be removed). Covered with: Insulation Apache Building Products "Pyrox White ", 2 in min, Base Sheet: Type G2, mechanically fastened or adhered with hot mechanically fastened. roofing asphalt. Membrane: "EverGuard SR ", 40-100 mil (TPA). Membrane: "Ruberoid® Torch 1" (modified bitumen), heat fused. 2. Deck: NC Incline: 1 Surfacing: Gibson - Homans "Black Jack 5176 Fibered Aluminum Roof 1,7 Base Sheet Type G3, hot mopped or nailed. Covering" or "PC 401 Fibered Aluminum Roof Coating" at 2 gal /sq. Insulation: Firestone Building Products "Iso- 95+GL ", Atlas Roofing 5. Deck: C -15/32 Incline: 1 "ACFoam II" or Johns Manville "E'NRG'Y 2G ", any thickness. Existing Roof: Class A BUR covered with: , Membrane: " EverGuard SR ", 40-100 mil (TPA). Insulation: Isocyanurate, 1 in. min, covered with 1/2 in. fiberboard. . 3. Deck: NC Incline: 1/2 Membrane: EverGuard SR ", 40 -100 mil (TPA), mechanically fastened. Base Sheet Type G3, hot mopped or nailed. 6. Deck: C -15/32 Incline: 1 Insulation: Celotex "Energy -Loc" or "Top -R -II", any thickness. Existing Roof: Class A BUR covered with: Membrane: " EverGuard SR ", 40 -100 mil (TPA). Insulation: Isocyanurate, 1 in. min, covered with 1/2 in. fiberboard. 4. Deck: C -15/32 Incline: 1/2 Membrane: "EverGuard FB ", 40-100 mil (TPA). Slipsheet One or more layers Atlas Roofing "FR 50", mechanically Class B fastened. 1. Deck: C-15/32 Incline: 1/2 Membrane: EverGuard " TPOSR" or "EGSR ", 40-100 mil, mechanically Existing Roof System: Class A or B covered with: fastened. Base Sheet: Celotex "Celo -Glas Cap Sheet ", granule surface down. Deck: C -15/32 Incline: 1/2 Membrane: "Ruberoid® Torch 1" (modified bitumen), heat fused. Slipsheet One or more layers Atlas Roofing "FR 10" or "FR 50", Surfacing: Karnak Chemical "Karnak No. 97 Fibrated Aluminum mechanically fastened. Asphalt Roof Coating" at 1 to 2 gal / sq. Insulation: Apache "Pryox" or Atlas Roofing " ACFoam II" 2 in. min, 2. Deck: NC Incline: 1/2 mechanically fastened. Existing Roof System: Class A or B gravel or smooth surfaced, covered Membrane: EverGuard "TPOSR" or "EGSR ", 40-100 mil, mechanically with: fastened. Base Sheet: Type G2 or G3 (inverted), mechanically fastened or adhered Class C - Mechanically Fastened with hot roofing asphalt. 1. Deck: C -15 /32 Incline: 1-1/2 Membrane: "Ruberoid® Torch 1 ", heat fused. Gypsum Board (Optional): 1/2 in., mechanically fastened. Surfacing: Henry "No. 523 Fibered Aluminum" at 1 to 2 gal /sq ft or Insulation: Rmax "Ply I" or "Multi- Max ", Apache Building Products GEO Industries "No. 923 Fibered Aluminum" at 1 to 2 gal / sq ft. "Pyrox White ", Firestone Building Products "Iso 95+GL ", Atlas Roofing 3. Deck: C -15/32 Incline: 1/2 " ACFoam II", Johns Manville " E'NRG'Y 2G ", 1 -1/2 in. thick min, Existing Roof System: Class A or B covered with: mechanically fastened or hot mopped. Base Sheet Celotex "Celo -Glas Cap Sheet", granule surface down. Membrane: "EverGuard SR ", 40 -100 mil (TPA). Membrane: "Ruberoid® Torch 1" (modified bitumen), heat fused. 2. Deck: NC Incline: 1-1/2 Surfacing: Gibson - Homans "Black Jack 5176 Fibered Aluminum Roof Gypsum Wallboard (Optional): 1/2 in., mechanically fastened. Covering" or "PC 401 Fibered Aluminum Roof Coating" at 2 gal / sq. • Insulation/Slip Sheet Polystyrene, 1-4 in. thick covered with glass fiber 4. Deck: NC Incline: 1/2 slip sheet. Existing Roof System: Class A or B gravel or smooth surfaced, covered Membrane: "EverGuard SR ", 40 -100 mil (TPA). with: 3. Deck: C -1 1/2 T & G Incline: 1 Base Sheet Type G2 or G3 (inverted), mechanically fastened or adhered Barrier Board: 3/8 in., min plywood. with hot roofing asphalt. LOOK FOR THE UL MARK ON PRODUCT