Permit A CITY OF TIGARD ��i� DEVELOPMENT SERVICES PE RM I PLUMP T # ING PERMIT (dpi I • PLM98 -0363 - 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639-4171 DATE ISSUED: 10/05/98 1 30\ PARCEL: 2S 1 O3CC--OO5OO SITE ADDRESS...: 15 SW 121ST AVE SUBDIVISION • ZONING: R -4.5 BLOCK • LOT • JURISDICTION: TIG CLASS OF WORK..:OTR GARBAGE DISPOSALS.: 0 MOBILE HOME SPACES.: 0 TYPE OF USE •SF WASHING MACH • 0 BACKFLOW PREVNTRS..: 0 OCCUPANCY GRP..:R3 FLOOR DRAINS • 0 TRAPS : 0 STORIES 0 WATER HEATERS 0 CATCH BASINS • 0 FIXTURES LAUNDRY TRAYS 0 SF RAIN DRAINS • 0 SINKS • 0 URINALS 0 GREASE TRAPS : 0 LAVATORIES • 0 OTHER FIXTURES • 0 TUB /SHOWERS...: 0 SEWER LINE (ft)...: 299 WATER CLOSETS.: 0 WATER LINE (ft)...: 380 DISHWASHERS • 0 RAIN DRAIN (ft)...: 0 Remarks: Installation of sewer line and water line to connect existing house. Owner: FEES FRED PASSMORE type amount by date recpt 7501 SW 195TH PLACE PRMT $ 160.00 DST 10/05/98 98- 309714 ALOHA OR 97007 SPCT $ 8.00 DST 10/05/98 98- 309714 Phone #: Contractor SUNRISE EXCAVATING INC 3351 SW WEST SHORE DR GASTON OR 97119 Phone #: 357 -3576 $ 168.00 TOTAL Reg #..: 90426 REQU INSPECTIONS This permit is issued subject to the regulations contained in the Sewer Inspection Tigard Municipal Code, State of Ore. Specialty Codes and all other Water Line Insp applicable laws. All work will be done in accordance with Misc. Inspection approved plans. This permit will expire if work is not started Final Inspection within 1:. days of issuance, or if work is suspended for more than 186 days. ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952- 8001-8010 through OAR 952 -0081 -9888. You may obtain copies of these rules or direct questions to OUNC by calling (593)246 -1987. s of t • Permittee Si gnat ar +++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ Call 639 -4175 by 7 :00 p.m. for an inspection needed the next business day +++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ CITY OF TIGARD Plumbing Permit Application Plan c 13125 SW HALL BLVD. Commercial and Residential Recd t '). TIGARD, OR 97223 Date Rec'd f 2 "5" Ju (503) 639 -4171 Date to P.E. Print or Type Date to D T Incomplete or illegible applications will not be accepted Permit# Li /t 3& - Related SWR # Called Name of Development/Project FIXTURES (individual) QTY PRICE AMT 1 Job / -1)0■i7 Sink 9.00 Address Street Address 1 .y- Suit Lavatory 9.00 3r W � 1). 5 Tub or Tub /Shower Comb. 9.00 Bldg # City /State Zip Shower Only 9.00 11 GAD q 7,3,2 3 Name Water Closet 9 Ft,H Dishwasher 9.00 Owner Mailing Address ---T“ n Suite Garbage Disposal 9.00 75 SIN i 9 5 f i L Washing Machine City /State Zi Phone 9.00 r� + ct 7 cc.7 6 4 1 , cj/ Floor Drain /Floor Sink 2" 9.00 Name / 7 3" 9.00 V ) rr • 4" 9.00 Occupant Mailing Address Suite Water Heater 0 conversion 0 like kind 9.00 Gas piping requires a separate mechanical permit. City /State Zip Phone Laundry Room Tray 9.00 Urinal 9.00 me E l(e- n 1 " le-9- Other Fixtures (Specify) 9.00 Contractor Mailing Address _ /' 1 ' Suite 9.00 ,535 7 ,..0..) Gv�%�3//J U . 9.00 Prior to permit ity /State Ip Phone Sewer - 1st 100' ��� 30.00 issuance, a copy 1�% Q/i C/ 7//9 35 7- 7 c s"i 25.00 S �o Sewer - each additional 100' of all licenses are Or on Cost. Cont. Board Lic.# Exp. Date required if y , /,9,6, 4 / - / � , - 7 q Water Service - 1st 100' 'r ; / 30.00 30 . co expired in COT Plumbing Lic. # Exp. Date / Water Service - each additional 200' Z 25.00 co. 00 database Storm & Rain Drain - 1st 100' 30.00 Name Storm & Rain Drain - each additional 100' 25.00 Architect Mobile Home Space 25.00 Or Mailing Address Suite Commercial Back Flow Prevention Device or Anti- 25.00 Pollution Device Engineer City /S Zip Phone Residential Backflow Prevention Device* 15.00 (Irrigation timing devices require a separate Describe work to be done: restricted energy permit.) New 0 Repair 0 Replace with like kind: Yes 0 No 0 Any Trap or Waste Not Connected to a Fixture 9.00 Residential 0 Commercial 0 Catch Basin 9.00 Additional description of work: _ dc,)N E i Ex/fi -n ti a. /�LC S / � o Sgi-o e- Insp. of Existing Plumbing 40.00 per /hr p- it>/' -7"f. 1)_._ g kV/ el__ , Specially Requested Inspections 40.00 per /hr Rain Drain, single family dwelling 30.00 Are you capping, moving or replacing any fixtures? Grease Traps 9.00 Yes O No O If yes, see back of form to indicate work performed by QUANTITY TOTAL fixture. FAILURE TO ACCURATELY REPORT FIXTURE Isometric or riser diagram is required if Quantity Total is > 9 Get. WORK COULD RESULT IN INCREASED SEWER FEES. *SUBTOTAL Q I hereby acknowledge that I have read this application, that the information ; 'C ' given is correct, that I am the owner or authorized agent of the owner, and 5% SURCHARGE p that plans submitte are in compliance with Oregon State Laws. Signal / rier /Agent Date * *PLAN REVIEW 25% OF SUBTOTAL .02.4-0--*--- Je Required only if fixture qty. total is> 9 / ` TOTAL A6 Contact Person me Phone 4j fi g -p r S /`7 C Q Z .-(S f *Minimum permit fee is $25 + 5% surcharge, except Residential Backflow Prevention Device, which is $15 + 5% surcharge * *AII New Commercial Buildings require plans with isometric or riser diagram ( " 1 ''' and plan review �j 1:ldststplumapp.doc 7 /2/98 ^ 3 7 PLEASE COMPLETE: .................... . Fixture Type Quantity by Work Performed New Moved Replaced Removed /Capped' Sink Lavatory Tub or Tub /Shower Combination Shower Only Water Closet Dishwasher Garbage Disposal Washing Machine Floor Drain /Floor Sink 2" 3" 4" Water Heater Laundry Room Tray Urinal Other Fixtures (Specify) COMMENTS REGARDING ABOVE: I: Wstskplumapp.doc 777/98 CITY OF TIGARD BUILDING INSPECTION DIVISION al - -- 24 -Hour Inspectio Line: 639 -4175 i E3usiness Line: 639 -4171 BUP ) � te - quested AM PM [ _2 l � BLD Location t {i: 4 1.8 S 1 \. 0 Suite MEC Contact Pera 0 • - ' / Ph 3_57- R (i/6 - q O 6 3 Contractor &SS on 0.1-Q-/ Ph ,2 -- / 5 / SWR BUILDING Tenant/Owner ELC Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear JGL 1. ) `'t'C, �� '° „` n � /� 1� ��%i'J 1 Framing r- - (✓ Insulation rr /�_ �, 1� , / Drywall Nailing J I �_ [ Fire wall 1 Yil ' / Fire Sprinkler Fire Alarm Susp'd Ceiling Roof � ,Q, \ r Misc: Final ` A S T�ii J ' t ! ��� v-1-L____e_7 PASS PART FAIL ( - ,.�U� Post & Beam Under Slab / �� .� UV ( ,�`�/ Q �j� \.L.-e S -1/('\/ VV\ Top Out QNater Se vic `�L 0 \ S Sanitary Sewer / Rain Drains 1 1. {- ,(� ` (flA., Q 9.- / le c._., PASS PART FAIL L. At _ AL■L —• AN: N M P1 8,11[3 NICAL 1 MIL .., _. k - - • • - - Y - 0 • - - - ‘ - 1 - eam e ' 1L R In �J .r AL A. �t I _ ` l_, - Smoke Dampers C AAr1. `„ D - • Final Y �J� PASS PART FAIL ELECTRICAL -, Service Rough In UG/Slab e (-)` t"` 5 5 QM Low Voltage \A AS (n ` /1 ,...., e s Fire Alarm 1, �J (1L/ FPal It PASS PART FAIL - i r I SITE - I OM tu_1(\ 1 / � rr IO _ •� • „e l Backfill /Grading U ./IA.3, " Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before ne • : section. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA Approach /Sidewalk Other D 1 ` v - ` c( Inspector `\ 1 CY— Ext Final PASS PART FAIL 0 N T REMOVE this inspection record from the job site. 5/10/00 Activities for Case #: PLM98 -00363 2:31:35 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes PLMA003 Application received 10/5/98 DEB RECD DST 10/5/98 PLMA005 Create Permit 10/5/98 DEB DONE DST 10/5/98 PLMA799 Final Inspection DST 10/5/98 PLMA705 Sewer Inspection 1015/98 10/26/98 RB FAIL RB 10/26/98 0937 am Septic tank pump ticket and fill ticket req'd. No test on sewer. 3034 (green) piping prohibited w /in 5 -feet of building. Maintain proper depth of sanitary line & 30 gpm flow /slope capacity. PLMA710 Water Line Insp 10/5/98 11/2/98 RB PASS RB 11/2/98 1 -1/2" SERVICE MAINTAIN DEPTH OF TRENCH FOR • WATER LINE. PLMA740 Misc. Inspection 10/5/98 DST 10/5/98 PLMA050 (F) Issue permit 10/5/98 DEB MEMO DST 10/5/98 Per instructions of Jill A. okay to issue this plumbing without issueing the sewer permit at this time. The sewer permit is to be issued at the same time as the SOP permit. PLMA705 Sewer Inspection 12/29/98 RB PASS J *H 10/30/98 See SWR98 -0274 PLMA800 Case Finaled 12/11/98 JT 12/11/98 Page 1 of 1