Loading...
Permit CITY OF TIGARD ELECTRICAL PERMIT DEVELOPMENT PERMIT #: ELC97-0614 ~="��"�"�~~" "°""�"�" SERVICES DATE ISSUED: 09/16/97 'nL 13125 SW Hall 8Nd Tigard, 099720(503) 639-4171 PARCEL: 2S103BD-00900 SITE ADDRESS...:12540 SW 121ST AVE SUBDIVISION • ZONING:R-4.5 BLOCK • LOT • JURISDICTION: URB Project Description: Replace existing elect. serivce with a new 200 amp service and four (4) branch circuits for an existing single family dwelling. ---RESIDENTIAL UNIT---- ---TEMP SRVC/FEEDERS---- MISCELLANEOUS 1000 SF OR LESS • 0 0 — 200 amp • 0 PUMP/IRRIGATION • 0 EACH ADD'L 500SF...: 0 201 — 400 amp . 0 SIGN/OUT LINE LTG..: 0 LIMITED ENERGY : 0 401 — 600 amp • 0 SIGNAL/PANEL • 0 MANF. HM/ SVC/FDR..: 0 601+amps-1000 volts.: 0 MINOR LABEL (10)...: 0 ----SERVICE/FEEDER---- ----BRANCH CIRCUITS ---ADD'L INSPECTIONS--- 0 — 200 amp • 1 W/SERVICE OR FEEDER: 4 PER INSPECTION • 0 201 — 400 amp : 0 1st W/O SRVC OR FDR.: 0 PER HOUR • 0 401 — 600 amp • 0 EA ADD'L BRNCH CIRC: 0 IN PLANT • 0 601 — 1000 amp • 0 PLAN REVIEW SECTION 1000+ amp/volt • 0 >=4 RES UNITS • > 600 VOLT NOMINAL..: Reconnect only • 0 SVC/FDR >= 225 AMPS..: CLASS AREA/SPEC OCC.: Owner: — FEES STEVEN P ALLEN type amount by date recpt 12540 SW. 121ST AVENUE PRMT $ 80.00 GEO 09/16/97 97-299283 TIGARD OR 97223 5PCT $ 4.00 GEO 09/16/97 97-299283 Phone #: 590-3671 Contractor: OWNER $ 84.00 TOTAL REQUIRED INSPECTIONS Rough—in Elect'l Service Phone #: Underground Cove Elect'l Final Reg #..: 999999 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Oregon Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-N10 through OAR 952-001-1'; . You ay obtain a copy of these rules or direct questions to (1UNC by calling )246-1987. Permittee Signature: , �� Issued By: P �~ OWNER INSTALLATION ONLY — The installation is being d on property I own which is not intended for sale, lease, or rent OWNER' S SIGNATURE : ATE: 67 - �'� -�� ~� � x +~ v u� � CONTRACTOR INSTALLATION ONLY --- SIGNATURE OF SUPR. ELEC'N: DATE: �� , `- ��' -x ^r— � / LICENSE NO: +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Call 639-4175 by 6:00 p.m. for an inspection needed the next business day +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ CITY OF TIGARD Electrical Permit Application Plan Check # 13125 SW HALL BLVD. Rec'd By TIGARD OR 97223 Date Recd Date to P.E. Phone (503) 639 -4171, x304 Date to DSI Print or Type Inspection (503) 639 -4175 Incomplete or illegible will not be accepted Permit # tC C o � l 'O� /�f Fax (503) 684 -7297 Called 1. Job Address: �1 4. Complete Fee Schedule Below: Name of Development 5 �O Number of Inspections per permit allowed Name (or name of business) Service included: Items Cost Sum I Address / 25 O 5ci, / ZI 5 4a. Residential - per unit q 1000 sq. ft. or less $110.00 4 i City /State /Zip , tt -d Or 3 Each additional 500 sq. ft. or portion thereof $25.00 1 Commercial ❑ Residential Limited Energy $25.00 Each Manuf'd Home or Modular Dwelling Service or Feeder $68.00 2 2a. Contractor installation only: (Attach copy of all current licenses) 4b. Services or Feeders Electrical Contractor Installation, alteration, or relocation OIL Address 200 amps or less _L. $60.00 ((ft) 2 201 amps to 400 amps $80.00 2 City State Zip 401 amps to 600 amps $120.00 2 Phone No. 601 amps to 1000 amps $180.00 2 Job No. Over 1000 amps or volts $340.00 2 Reconnect only $50.00 2 Elec. Cont. Lice. No. Exp.Date OR State CCB Reg. No. Exp.Date 4c. Temporary Services or Feeders COT Business Tax or Metro No. Exp.Date Installation, alteration, or relocation 200 amps or less _Silie $50.00 2 Signature of Supr. Elec'n 201 amps to 400 amps $75.00 2 401 amps to 600 amps $100.00 2 Over 600 amps to 1000 volts, License No. Exp.Date see "b" above. Phone No. 4d. Branch Circuits New, alteration or extension per panel 2b. For owner installations: a) The fee for branch circuits with purchase of service or Print Owner's Name S'4Cc 1e 1 en feeder fee. Address 1 2.S 1 /Q Su.) 121 3 Each branch circuit i $5.00 20 2 Tl ` a r State are. Zip b) The fee for branch circuits City Q d p without purchase of Phone Ne. 5 'jO -- 47 I service or feeder fee. First branch circuit $35.00 2 The installation is being made on property I own which is not Each additional branch circui $5.00 2 intended for sale, lease or rent. 4e. Miscellaneous / (Service or feeder not included) Owner's Signature l'. ■G� Each pump or irrigation circle $40.00 2 Each sign or outline lighting $40.00 2 3. Plan Review section (if required):* Signal circuit(s) or a limited energy panel, alteration or extension $40.00 2 Minor Labels (10) $100.00 Please check appropriate item and enter fee in section 5B. 4 or more residential units in one structure 4f. Each additional inspection over Service and feeder 225 amps or more the allowable in any of the above System over 600 volts nominal Per inspection $35.00 Classified area or structure containing special occupancy Per hour $55.00 as described in N.E.C. Chapter 5 In Plant $55.00 g am * Submit 2 sets of plans with application where any of the above apply. 5. Fees: g _ j Not required for temporary construction services. 5a. Enter total of above fees $ ■ ��_ 5% Surcharge (.05 X total fees) $ 9 NOTICE Subtotal $ 5b. Enter 25% of line 5a for PERMITS BECOME VOID IF WORK OR CONSTRUCTION AUTHORIZED IS Plan Review if required (Sec.3) $ NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK Subtotal $ IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. ❑ Trust Account # Total balance Due $ I: \DSTS \ELC96.APP Rev 9/96 CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP Date Requested AM PM BLD Location ZS Lk) 1 7/ Si AVE E Suite MEC Contact Person Ph / PLM Contractor. `loll o / l Ph S1 1) _3 - t SWR �1 BUILDING Tenant/Owner ELC 9 d -00tP Retaining Wall ELR Footing Access: n Foundation FPS Ftg Drain IIICCC...eee Crawl Drain Inspection Notes: (l ,' SGT Slab Je �'� / SIT Post & Beam Ext Sheath /Shear ( ViVE Int Sheath /Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm "s� Susp'd Ceiling Roof Misc: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Top Out Water Service Sanitary Sewer Rain Drains Final PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final PASS 1 FAIL . 5ECTRICA Service Rough In UG /Slab Low Voltage Fire Alarm ART FAIL SITE- - Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next i section. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: J Unable to inspect - no access ADA Approach /Sidewalk Other Date �� Inspector A.._ ,i �h�jl Ext Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site.