Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
26GA. CONT. 3" BAIT STRIP SPECIFICATIONS WITH #8 TEK SCREW - 14' -0 [168] 023" O.C. BOTH SIDE —I CONSTRUCTION: / / (IF TOP CAP CAN'T I WALL: 31/2" WOOD- FRAME, POLYURETHANE, F -I -P COOLER BE INSTALLED) 3/8" X 6" LAG BOLT CEILING: 3 )4" WOOD- FRAME, POLYURETHANE, F -I -P AND WASHER 023" O.C. 1" X 61" CONT. 26GA. FINISH: GALV. STEEL TOP CAP METAL WALL: ST /G EXTERIOR WITH #8 X 5/8' TEK CEILING: ST /GALV. INTERIOR SCREWS 023" O.C. 1 CEILING PANEL ST /GALV. EXTERIOR ilir CAULKING I ACCESSORIES: � 1 EA. - 36 X 80' HINGED COOLER DOOR NSF GASKET— g o NSF GASKET 2 EA. - COMPACT FLUORESCENT LIGHT FIXTURE o 2z WOOD SHIP LOOSE (BULB INCLUDED) FOAA1 td a b r 0 — 2 WITH METERLOT LIGHT # 1 WAL PANEL Q a • - 36" X 80" FLEX BARRIER PLASTIC CURTAIN IN 0 CEILING TO WALL �i i o g. DOWN CEILING x _ - g E ; CEILING IS DESIGNED FOR "NO STORAGE" GON STICKER / M EXTERIOR ! a w c'. l FOAM 2X4 CAULKING • . : 4 v C rn /-M METAL P l n n I� i V I�. Z t� � :. � ,20 C7 n VIII ; ► o T ° NM V PLUG BUTTO CAM LOCK FASTENER ao! �� ' � O ..=, r PLAN VIEW ,� p SILICONE CD INTERIOR EN 3=` a • _ PANEL TO PANEL SUBMITTAL DRAWING s os � �1 AhtirsSIGNED & RETURNED BY _ o o L 2 ''.... TO BE SHIPPED ON 05125/10 __ 1 E XTERIOR INTERIOR ❑ NOT APPROVED - REVISEANDRESUBMIT I IF ❑ APPROVED AS NOTED - MANUFACTURE AS NOTED 3/4' X 3/4" X 16GA. APPROVED AS IS - MANUFACTURE AS DRAWN o GALV, STEEL ANGLE °f WALL PANE #14 X 234 TEK 1 4 7 SCREWS CaVE X30 ®a HILTI DRNE PINS 7 WITH MIN. 1 1/2' d EMB. 0 23" 0.C. (ESR 2269) FRONT ELEVATION 25675) 0 ^ 'l l WALL TO CONCRETE FLOOR A c<j CI) REV. aTE DESCRIPTION _ REM. B1' , ! , J SECTION 340 OF THEEN RGY POLICY A D ERVATION AC US,C, 6311) (gUE7C1) J ©OO r-IM ©D u WALLS, CEILINGS, FLOORS AND DOORS 11210 INLAND AVE. MIRA LOMA, CA 91752 M eans Temp 3�" 4" 5" 5�" Federal Law min. R= TEL: (951) 361 -0886 FAX: (951) 361 -0906 "� JOB COSTNER Cooler's 55 R =25.4 R =29.1 R =38.4 R=40 R =25 EQUIPMENT WHOLESALERS Freezer's 20 R =32.4 R =40.8 R=44.7 R =32 PORTLAND, OR °R'" e. REKEMA D'A"NG N Floor's _ 20 R =28.4 R =32.4 R=40.8 R=44.7 R =28 DATE 04/28/10 101339 - ASTM method C: - 518 COOLER DEAL' 3/8 " =1' - 0" 1 • r 26GA. CONT. 3" BATT STRIP SPECIFICATIONS - WITH #8 TEK SCREW - 14' -0" [1681 023" O.C. BOTH SIDE CONSTRUCTION: x Y (IF TOP CAP CAN'T WALL: 4" FOAM- FRAME, POLYURETHANE, F -I -P FREEZER BE INSTALLED) 3/8" X 6" LAG BOLT CEILING: 4" FOAM- FRAME, POLYURETHANE, F -I -P i AND WASHER 023" O.C. FLOOR: ONE (1) LAYER POLYURETHANE, OF 3/4" (BUILT -IN) ON TOP 1" X 6{h" CONT. 26GA. GALV. STEEL TOP CAP WITH 8 X 5/8" TEK METAL FINISH: SCREWS 023" O.C. ST /GALV. EXTERIOR CEILING PANEL WALL: ST /GALV. INTERIOR CAULKING CEILING: ST /GALV. INTERIOR " 1 ST /GALV. EXTERIOR FLOOR: .050 SM /ALUM, INTERIOR W /NON SKID STRIP NSF GASKET — no ST /GALV. EXTERIOR o NSF GASKET ° 2z WOOD ACCESSORIES: pi 1 EA. - 36" X 80 HINGED FREEZER DOOR V- WALL PANEL = FOAM SELF - CLOSING o I #2 2 SHIP LOOSE (BULB FLUORESCENT FIXTURE N CEILING TO WALL 1 EA. - LIGHT SWITCH WITH PILOT LIGHT 1 EA. - 2" DIAL THERMOMETER EXTERIOR 1 EA. - HEATED AIR VENT #1825 1 EA. - 36" X 80 FLEX BARRIER PLASTIC CURTAIN FOAM STUDS -,�\ - CAULKING NOTE: LAG DOWN CEILING -METAL THE CEILING IS DESIGNED FOR "NO STORAGE" - f--------CL-...„,......40-------- FOAM p;� OREGON STICKER `_ 1 Will 5 / 3' 5' PLUG BUTTON CAM LOCK FASTENER 048 "O.C. MAX. PLAN VIEW SILICONE - INTERIOR PANEL TO PANEL SUBMITTAL DRAWING MUST BE SIGNED & RETURNED BY _ 05L06110 a. ® Q EXTERIOR INTERIOR TO BE SHIPPED ON 05125110 U 0 NOT APPROVED - REVISE AND RESUBMIT P3' WALL PANEL 0 APPROVED AS NOTED - MANUFACTURE AS NOTED O 1 1/2" X 6 1/2" X 160k- 3/4 X 3/4" X 16GA. 0 APPROVED AS IS - MANUFACTURE AS DRAWN o GALV. STEEL ANGLE r GALV. STEEL ANGLE '- "v, 0 #14 X 114 TEK #14 X 3" TEK PRdDdIEp7 DD UEs OD �� SCREWS 023" O.C. � SCREWS 023" O.C. DD G414fs �OC�3G� r` #12 K SCREWS FLOOR PANEL 012" 0.C. / / / /7/0 / / / / //% ® HILTI DRIVE PINS 1 WITH MIN. 1 1/2" EMB. 0 23" O.C. (ESR 2269) FRONT ELEVATION (LARR 25675) WALL TO PRE -FAB FLOOR A REV. 5EE OESCRIPTIDR REV. ar FEDERAL LAW EFFECTIVE 1/1/2009 OUe1TOIJVIJ ©OOII OH& SECTION 340 OF THE ENERGY POLICY AND CONSERVATION ACT (42 U.S.C. 6311) WALLS, CEILINGS, FLOORS AND DOORS 11210 INLAND AVE. MIRA LOMA, CA 91752 TEL: (951) 361 -0886 FAX: (951) 361 -0906 Means Temp 34" 4" 5" 54" Federal Law min. R= Joe CUSTOMER Coolers 55 R =25.4 R =29.1 R =38.4 R-40 R =25 EQUIPMENT WHOLESALERS Freezer's 20 R =32.4 R=40.6 R =44.7 R =32 PORTLAND, OR O' RE REKEMA D''' "D "O Floors 20 R =28.4 R =32.4 R=40.6 R=44.7 R =28 wa 04/28/10 101339 - ASTM method C - 518 FREEZER SCM.E 3/8 " =1' -O"