Loading...
Permit w CITY OF TIGARD MECHANICAL PERMIT Il l 1 COMMUNITY DEVELOPMENT Permit #: MEC2011 -00187 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 04/29/2011 Parcel: 2S113AC00103 Jurisdiction: Site address: 7244 SW DURHAM RD 600 Project: Tolt Subdivision: PACTRUST BUSINESS CENTER Lot: 0 Project Description: Move and add grilles for new tenant. Contractor: OREGON HEATING & AIR CONDITIONING Owner: PACTRUST PO BOX 241 15350 SW SEQUOIA PKWY #300 DUNDEE, OR 97115 PORTLAND, OR 97224 PHONE: 503 - 691 -9699 PHONE: 503 - 624 -6300 FAX: 503 - 691 -8556 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 04/29/2011 $204.14 Class of Work: ALT Type of Const: Plan Review 04/29/2011 $51.04 Occupancy Grp: Occupancy Load: 12% State Surcharge - Mechanical 04/29/2011 $24.50 Stories: Project Valuation: $4,900.00 Fuel Air Handlers Fuel Types: Units < 10000 cfm: Gas Pressure: Units > 10000 cfm: Furnaces Boilers & Compressors Furnaces < 100K BTU: 0 -3 HP: Furnaces >= 100K BTU: 3 - HP: Floor Furnaces: 15 - 30 HP: Unit Heaters: 30 -50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $279.68 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports (Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire /Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is of started within 180 days of issuance, or ' is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the ul s adopted by the Oregon Utility "cation Cente Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0090. •u y •btain a copy of the rules or d' ct questions to OUN alli g 5 .232.1987 or 1.800.332.2344. ' Iss ed By: / Permittee Signature: �I Call 503.639.4175 by 7:00 a.m. for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit ApplicatiREC F FOR OFFICE USE ONLY City of Tigard D ateived A/ 11 7 Permit No.: �l/ ���� M ill • 13125 SW Hall Blvd., Tigard, OR 97223 APR 2 9 2011 y. Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Other Permit: T I G A R h Inspection Line: 503.639 CITY OF TIGA9D Date Ready/By: Juris: ® See Page 2 for Internet: www.tigard or.gov BUILDING DIVISION Notified/Method: Supplemental Information TYPE OF WORK COMMERCIAL FEE* SCHEDULE - USE CHECKLIST Mechanical permit fees* are based on the value of the work ❑ New construction Addition/alteration /replacement performed. Indicate the value (rounded to the nearest dollar) of all ❑ Demolition Other: mechanical materials, equipment, labor, yechead, and profit. Value: $ 4. j G 7/7ZJ CA I OF CONSTRUCTION RESIDENTIAL EQUIPMENT / SYSTEMS FEES* ❑ 1 -and 2- family dwelling Commercial /industrial ❑Accessory building For special information use checklist. ❑ Multi- family ❑ Master builder ❑ Other: Description Qty. I Ea. I Total 1 JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning Job site address: 9z / - ) l v !%j../)7, ljYyrh (requires site plan showing placement) 46.75 City /State /ZIP: / V (l✓ Furnace 100,000 BTU (ducts/vents) 46.75 / / /Furnace 100,000+ BTU (ducts/vents) 54.91 �� /(/ C��[1 Suite/bldg. /apt. no.: 60z; Project name: 1j,4�f Heat pump (requires site plan showing placement) 61.06 Cross street/directions to job site: Duct work 23.32 7 �Of Hydronic hot water system 23.32 / Residential boiler (radiator or hydronic) 23.32 Unit heaters (fuel -type, not electric), in -wall, in -duct, suspended, etc. 46.75 Subdivision: Lot no.: Flue /vent for any of above 23.32 Other: 23.32 Tax map /parcel no.: Other fuel appliances: DESCRIPTION OF WORK Water heater 23.32 � l °(/ Gas fireplace 33.39 �/�/( r 6 �Flue vent vent for water heater or gas yuritt' fireplace 23.32 Log lighter (gas) 23.32 Wood/pellet stove 33.39 Wood fireplace /insert 23.32 PR ERTY OWNER I ❑ TENANT Chimney/liner /flue /vent 23.32 Other: 23.32 Name: ‘/)11 ra . Environmental exhaust and ventilation: Address: Range hood/other kitchen equipment 33.39 City /State /ZIP: Clothes dryer exhaust 33.39 Phone: Single -duct exhaust (bathrooms, ( ) Fax: ( ) toilet compartments, utility rooms) 23.32 APPLICANT ,1 CONTACT PERSON Attic /crawlspace fans 23.32 �) / 4 L Other: 23.32 Business name: Fuel i m P p g: Contact name: C // d. /eh i nz y $14.15 for first four; $4.03 for each additional Address: K., 1 Furnace, etc. Gas heat pump City /State /ZIP: Ov ,0e az Qj 71(< Wall/suspended/unit heater Phone: (i/53) v./ 5 Rt& I Fax: : ( ) /! Water heater E -mail: / l ,, Fireplace �,/jtf L 0 a V� £ &41') l i e. ) Range CO CT Barbecue /4) l i Clothes dryer (gas) Business name: (j ' � t -C ... ., Address: ( /1 MECHANICAL PERMIT FEES* ) .! Other: q (/ (/ City/State /ZIP: O _,/XO a, 7l/ S Subtotal Phone: 01 ) se;-. 2-i? 51 Fa ( ) Minimum permit fee ($90.00) Plan review (25% of permit fee) CCB lic.: I ', 2 ( 'z_� State surcharge (12% of permit fee) l TOTAL PERMIT FEE 1 Authorized signature: a This permi application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: IT . i 7 � 7/iLf1�,Date: 7 1 j • Fee methodology set by Tri -County Building Industry Service Board I: \ B uilding \Permits'MEC- PermitApp.doc 09/09/10 �^' 440-4 17T(11 /0 OM/WEB) Mechanical Permit Application - City of Tigard Page 2 - Supplemental Information Commercial & Multi- Family Fee Schedule: Total Valuation: Permit Fee: $0.00 to $500.00 Minimum fee $69.06 $500.01 to $5,000.00 $69.06 for the first $500.00 and $3.07 for each additional $100.00 or fraction thereof, to and including $5,000.00. $5,000.01 to $10,000.00 $207.21 for the first $5,000.00 and $2.81 for each additional $100.00 or fraction thereof, to and including $10,000.00. $10,000.01 to $50,000.00 $347.71 for the first $10,000.00 and $2.54 for each additional $100.00 or fraction thereof, to and including $50,000.00. $50,000.01 to $100,000.00 $1,363.71 for the first $50,000.00 and $2.49 for each additional $100.00 or fraction thereof, to and including $100,000.00. $100,000.01 and up $2,608.71 for the first $100,000.00 and $2.92 for each additional $100.00 or fraction thereof. Note: All new commercial buildings require 2 sets of plans. I:\Building\Permits\MEC- PermitApp.doc 09 /09/10 2 I 1 I t IMAM DOOR IN QOM) >dn 62 f 8..8..r el.arna. .rarao a a.r.a... 1.11 arr....rn....w 6111111111111111111 1 .111.11.1111i111111111•11111111111 0 11.611111111111111.1•111111111111111111111111 (0 :/ e € Q I , �^ fDr -! Scope of Work ikki b V� ) ® �; �0 Q , ' • Oregon Heating and Air Conditioning will perform the following scope of work: ol, i 1 >N _ �JJ 1. Ducting and air - distribution as drawn. Ma I -- ,�, L/"1 C I Equipment Schedule r1 • " t• .. 10 ` •°~• * Fsh � � Ventilation Requirements- based on 2010 OMSC table 403.3 i. I y � _��� I ! i RTU2 -multi -zone En 10. _ 4". , ! Office- 700 sft breathable zone vs. r ,.. l,4V Conference - 200 sft breathable zone q c ," tat» Reception- 200 sft breathable zone = I EPA. b . Ez = 0.8 (supply and return in ceiling) . . \ 1 o itt i r,, 0�1 =`' ` - Vpz = 1200 cfm I f e r�I / .2-e7 / bra ;. t Net 700 sft office- 1 ' 7 1 2 - h-7 1 , � ` � Persons -5cfm X 5p /1000sft = 20 cfm Pz= 4 czr �: I Area- 0.06 cfmisft = 42 cfm 0-14. Z r �+ a . t . _ Vbz = 62 cfm a a V , V 78 c f m 1 EN .ICE " 14 i t T PtI lWt 1_ 4 Zp =0.04 r+1,3 , ism , MEN 44 1 - -J Net 200 sft conf- 1 I14 J + I I ® `� _ : Ell Persons -5cfm X 50p /1000sft = 50 cfm Pz =10 ■ f it� '1 .. .. �«...„ . .. .. 1 _ =^�F : Area- 0.06 cfm /sft = 12 cfm ---- -�-� • ` a Vbz = 62 cfm I ti I ��! ,� , I p !FIN_ . Voz= 78 cfm r ° _ ' � � , lir7bff8 M Zp =0.04 MN gli ..� , 1 d : MI = a 1� J , ' gig" Net 200 sft recent- . (26 4;1 x*i_ 1111 1 g ti'i )1 # t=t! . ` Persons -5cfm X 30p /1000sft = 30 cfm Pz =6 1 � �, - �, Ar ea- 0.06 cfm /sft = 12 cfm I ■ (X) :t d I 16 � � , ' '111 , ; I I I ,� V bz = 42 cfm ! i 1 I It� ,. a r — 7 Voz = 53 cfm TO !WAN -. _ Zp =0.03 1 e ` P,.111 ti E to iit d a I I Uncorrected OAI- 4, I illy r1 c � D° 1 >T. Vou= 100 +66 =166 cfm Vot = 208 cfm i ' SA = 1900 cfm t 1 .4446 I I 1 RA = 1690 cfm 1 4 WO F"+ ` R OSA = 210 cfm O NA I i VII 1 I ` *' r Ai�11 «BIB 1 °regon Heati au.c.no.s ng Il k t oe& r ,V ■ _ o— 1 I - , t 1- sots -: • #, c. __n____ _ _.,- _ T__.__�_ v. r .,,; _,,r.. _. 1 r t. ,. www.oregonheating.com ' . i I ' I f ' I I _ = II I I Mechanical General Notes: ( 1/ i/4 ■ Oregon Heating & A/C, Inc. 1. All ducting 9 galvanized ducting. be 26 a minimum alvanized steel ductin . Max 5' flex. PHONE NUMBERS MAILING ADDRESS OPERATIONS CONTRACTOR LICENSE 2. Heating and cooling ducting to be designed to not exceed 0.5 wc positive (supply) and 0.5 wc negative (return). 503 -691 -9699 PO Box 241 19300 SW 118 Ave Oregon CCB 172126 3. Provide programmable thermostat. 5 degree deadband minimum. 7 day. Microprocessor.Set program for night energy savings. 503-691-8556 (Fax) Dundee, OR 97115 Tualatin, OR 97062 Washington OREGOHC900BN 4. Seal ducting with UL listed mastic tape. 5. Max leakage rate of OSA or exhaust dampers to be 4 cfm/sft @ 1.0 sp. ? 1� M IC 20 I I — 00 I g' 7 1 6. Insulate all supply and return duct min. R4 foilback. OSA duct to be insulated R4 minimum. 7Z/-1-4 S puRHA,44 R9 )6)e) 1 Mi I III Irr . I I I *A Ti) sc L. PIPIRION I i u 01111•11 UMW 011 t 1, 9 4 4