FIELD OBSERVATION REPORT
DATES COVERED: July 5, 2000
PROJECT: Kaady Car Wash — King City
ADDRESS: 15450 SW 116 — King City, OR
BY: D. Elton
WEATHER: Overcast
PURPOSE OF VISIT: Observe Slab Demolition
Arrived on site, as requested, to observe basement slab demolition and shallow test pit
excavations. I met with Chuck (Ken Leahy Company) and viewed demolition with him. The
floor had been demolished with a rock chipper and about 8" diameter holes from chipper were
about every 2'. The slab was fractured into pieces about every 2' to 3'.
Two shallow test pits were excavated through the demolished slab. In general I observed
approximately two feet of 4" rock overlying medium stiff silt.
I also discussed the use of material from basement walls for backfill material. We recommend
the walls be removed and hauled off site.
Based on the observations above, the demolished floor slab appears to be in general
compliance with our project memorandum dated 5/17/00.
Dennis P. Elton, E.I. Reviewed by: TWB
Staff Engineer
Note: Our reports pertain to the locations observed at the time of our visit only Information
contained herein is not to be reproduced, except in full, without prior authorization from this
office.
•
DE /sab
Distribution: Robert Westlund General Contractors, Inc. — Fax 620 -0883
City of Tigard — Fax 684 -7297
RErFJAT
a • AUG 0 7 2000 onstruction Inspection & Related Tests
Carlson Testing, Inc.
Geotechnical Consulting
BY: P.O. Box 23814
JOB NO. 000015 75 Tigard, Oregon 97281
3-tit 70, 2000 Phone (503) 684 - 3460
REPORT OF IN -PLACE DENSITY TESTS FAX (503) 684 -0954
Client ROBERT WESTLUND GENERAL CONTRACTOR INC
Permit No:
Project KAADY CAR WASH - KING CITY
15450 SW 116TH KING CITY OR
Material Description 3/4 " -0 RECYCLED ROCK FROM KEN LFAHY CONSTRUCT ION
Max. Dry Density 1 ?4 . 2 lbs. /cu. ft. Optimum Moisture 13. 2 % Method of Test AASHTO T - R0
ASTM D2922,D3017
Standard Count Density: 3014 Moisture: 663 SeriaOnx1or 26149 WC. 3440
DATE OF TEST % ADJ. ELEV. FIELD IN - PLACE DENSITY
TEST NO TEST LOCATION DEPT PARTICLES DENS. FT. MOISTURE WE TLBS. /CU.
DRY /
COMPACTION
PS SOUTH SIDE -3' - 3'
7- .7 9.3 113.5 103.8 84
PS NORTHEAST CORNER - 4
2
7 -. 7 9.9 123.4 112.3 90
PS SOUTH SIDE -5' — J '
3
7- 7 11.4 121.4 109.0 88
PS SOUTH SIDE -3' - 3'
!
7... 7 10.0 121.8 110.7 89
Remar .: Density & Moisture Counts
90 REQ -3 AND 957. REQ ABOVE 3' . PS 1 2331, 127
cc : • TY • IIGARD PS 2 2698, 142
PS 3 2821, 157
PS 4 1845, 142
Tested by J. MODERIE /LRO Reviewed By CARL,QN TESTING INC
Our re Per t;a i n to ,the m�atgr i s 1 t� l teci� i rispect� >d are 1 r , t �F.
• I RECEIVED
Construction Inspection .& Related Tests
Carlson Testing, Inc. I AUG 0 4 2000 Geotechnical Consulting
JOB NO. 00001575 1JY: ___ P.O. Box 23814
Tigard, Oregon 97281
Aug 01, 2000 Phone (503) 684 - 3460
REPORT OF IN - PLACE DENSITY TESTS FAX (503) 684 - 0954
Client ROBERT WESTI . UND GENFRAI CONTRACTOR INC
Permit No:
Project KAADY CAR WASH - KING CITY
15450 SW 116TH KING CITY OR
Material Description 3/4" -fl RFCYCLFD ROCK FROM KFN I FAHY CONSTRUCTION
Max. Dry Density 124. 2 lbs. /cu. ft. Optimum Moisture 1 3 - 2 % Method of Test AASHT() T I An
ASTM D2922,1)3017
Standard Count. Density: 2.791 Moisture: 607 Serial 000x ler- 14489 NIIC 3440
DATE OF TEST % ADJ. FIELD IN -PLACE DENSITY
TEST LOCATION COARSE MAX. ELEV MOISTURE (LBS.Jc U.FT.)
TEST NO DEP PARTICLES DENS. FT. % WET DRY COMPACTION
PS NORTHWEST CORNER 0
8
/-13 5.3 120.0 114.0 . 92
PS EAST SIDE 0
9 __
-7-1.3 7.9 119.4 110.7 8
- PS SOUTHEAST CORNER 0
1 p A=P
7- - i 3 8.4 108.7 100.3 81
Was not able to retest any areas at
-1'. Left copy in Lot 215.
Rema s: (.-\
Density & Moisture Counts
957. REQUIRED PS 8 2023, 89
cc : (:.TY OF T I. ARD PS 9 2051, 105
PS 10 2776, 102
Tested by J . MODER IE /KAM • Reviewed By _. CARLSON TESTING INC.
O repor psrt.aj to the maeial to ed on�r.
Informa tion cont erein is n not to be repro ucte , r except in u I, wit out pr or a orization l ram this office.
15036200883 ROBERT WESTLUND GEN 304 P02 MAY 31 '00 12:40
Robert Westlund, General Contractor, Inc.
Specializing in Concrete
City of Tigard
Attn: Bob Poskins
RE: Authorization
This is a letter of authorization for Timothy Blackwood, Engineer for Carlson Testing