Loading...
Report 07/07/00 FRI 08:38 FAX 503 670 9147 CARLSON TESTING LJ 001 `E�i Carlson Geotechnical Office Salem Office :end Of P.O. Q. Box 23814 4060 Hudson Av _ P O. Box 7918 A Division of Carlson Testing, Inc. Tigard. Oregon 97281 Salem, OR 973' Bend, OR 97708 Geotechnical Consulting Phone (503) 684-3460 Phone (503) 589 -1252 Phone (541) 330 -9155 Construction Inspection and Related Tests FAX (503) 670.9147 FAX (503) 589 -1309 FAX (541) 330 -9163 5 -40D 0 July 6, 2000 CGT No. G0001575 Permit No. FIELD OBSERVATION REPORT DATES COVERED: July 5, 2000 PROJECT: Kaady Car Wash — King City ADDRESS: 15450 SW 116 — King City, OR BY: D. Elton WEATHER: Overcast PURPOSE OF VISIT: Observe Slab Demolition Arrived on site, as requested, to observe basement slab demolition and shallow test pit excavations. I met with Chuck (Ken Leahy Company) and viewed demolition with him. The floor had been demolished with a rock chipper and about 8" diameter holes from chipper were about every 2'. The slab was fractured into pieces about every 2' to 3'. Two shallow test pits were excavated through the demolished slab. In general I observed approximately two feet of 4" rock overlying medium stiff silt. I also discussed the use of material from basement walls for backfill material. We recommend the walls be removed and hauled off site. Based on the observations above, the demolished floor slab appears to be in general compliance with our project memorandum dated 5/17/00. Dennis P. Elton, E.I. Reviewed by: TWB Staff Engineer Note: Our reports pertain to the locations observed at the time of our visit only Information contained herein is not to be reproduced, except in full, without prior authorization from this office. • DE /sab Distribution: Robert Westlund General Contractors, Inc. — Fax 620 -0883 City of Tigard — Fax 684 -7297 RErFJAT a • AUG 0 7 2000 onstruction Inspection & Related Tests Carlson Testing, Inc. Geotechnical Consulting BY: P.O. Box 23814 JOB NO. 000015 75 Tigard, Oregon 97281 3-tit 70, 2000 Phone (503) 684 - 3460 REPORT OF IN -PLACE DENSITY TESTS FAX (503) 684 -0954 Client ROBERT WESTLUND GENERAL CONTRACTOR INC Permit No: Project KAADY CAR WASH - KING CITY 15450 SW 116TH KING CITY OR Material Description 3/4 " -0 RECYCLED ROCK FROM KEN LFAHY CONSTRUCT ION Max. Dry Density 1 ?4 . 2 lbs. /cu. ft. Optimum Moisture 13. 2 % Method of Test AASHTO T - R0 ASTM D2922,D3017 Standard Count Density: 3014 Moisture: 663 SeriaOnx1or 26149 WC. 3440 DATE OF TEST % ADJ. ELEV. FIELD IN - PLACE DENSITY TEST NO TEST LOCATION DEPT PARTICLES DENS. FT. MOISTURE WE TLBS. /CU. DRY / COMPACTION PS SOUTH SIDE -3' - 3' 7- .7 9.3 113.5 103.8 84 PS NORTHEAST CORNER - 4 2 7 -. 7 9.9 123.4 112.3 90 PS SOUTH SIDE -5' — J ' 3 7- 7 11.4 121.4 109.0 88 PS SOUTH SIDE -3' - 3' ! 7... 7 10.0 121.8 110.7 89 Remar .: Density & Moisture Counts 90 REQ -3 AND 957. REQ ABOVE 3' . PS 1 2331, 127 cc : • TY • IIGARD PS 2 2698, 142 PS 3 2821, 157 PS 4 1845, 142 Tested by J. MODERIE /LRO Reviewed By CARL,QN TESTING INC Our re Per t;a i n to ,the m�atgr i s 1 t� l teci� i rispect� >d are 1 r , t �F. • I RECEIVED Construction Inspection .& Related Tests Carlson Testing, Inc. I AUG 0 4 2000 Geotechnical Consulting JOB NO. 00001575 1JY: ___ P.O. Box 23814 Tigard, Oregon 97281 Aug 01, 2000 Phone (503) 684 - 3460 REPORT OF IN - PLACE DENSITY TESTS FAX (503) 684 - 0954 Client ROBERT WESTI . UND GENFRAI CONTRACTOR INC Permit No: Project KAADY CAR WASH - KING CITY 15450 SW 116TH KING CITY OR Material Description 3/4" -fl RFCYCLFD ROCK FROM KFN I FAHY CONSTRUCTION Max. Dry Density 124. 2 lbs. /cu. ft. Optimum Moisture 1 3 - 2 % Method of Test AASHT() T I An ASTM D2922,1)3017 Standard Count. Density: 2.791 Moisture: 607 Serial 000x ler- 14489 NIIC 3440 DATE OF TEST % ADJ. FIELD IN -PLACE DENSITY TEST LOCATION COARSE MAX. ELEV MOISTURE (LBS.Jc U.FT.) TEST NO DEP PARTICLES DENS. FT. % WET DRY COMPACTION PS NORTHWEST CORNER 0 8 /-13 5.3 120.0 114.0 . 92 PS EAST SIDE 0 9 __ -7-1.3 7.9 119.4 110.7 8 - PS SOUTHEAST CORNER 0 1 p A=P 7- - i 3 8.4 108.7 100.3 81 Was not able to retest any areas at -1'. Left copy in Lot 215. Rema s: (.-\ Density & Moisture Counts 957. REQUIRED PS 8 2023, 89 cc : (:.TY OF T I. ARD PS 9 2051, 105 PS 10 2776, 102 Tested by J . MODER IE /KAM • Reviewed By _. CARLSON TESTING INC. O repor psrt.aj to the maeial to ed on�r. Informa tion cont erein is n not to be repro ucte , r except in u I, wit out pr or a orization l ram this office. 15036200883 ROBERT WESTLUND GEN 304 P02 MAY 31 '00 12:40 Robert Westlund, General Contractor, Inc. Specializing in Concrete City of Tigard Attn: Bob Poskins RE: Authorization This is a letter of authorization for Timothy Blackwood, Engineer for Carlson Testing Laboratory, to be special inspector for the Kaady Car Wash project located in King city. 11515 S.W. Durham Road • Tigard, Oregon 97224 -3476 • Business: (503) 598-0618 • Fax: (503) 620 -0883 OR Contractor - 42503 • WA Contractor - ROBERWG141BH