Permit • f CITY OF TIGARD
„,,,, ; DEVELOPMENT SERVICES MASTER PERMIT
PERMIT #° ° ° ° ° . ° : MST96 -0556
13125 SW HaII Blvd., Tigard, OR 97223 (503)639-4171 DATE ISSUED: 01/30/97
,` PARCEL: 2S103BD -HG016
SITE ADDRESS...: 1274 - SW 116TH AVE
SUBDIVISION-.....: HUNTER'' LOT . � i 6 LEN • EXPIR JN I NG : R-4.5 PD
BLOCK..........:
Remarks: Path 1
- -- --------------- - ----- - - -- -- BUILDING --------------- ---- - - -- - -- - --- -- - --- -- ---- ----
REISSUE:MST96 -0462 STORIES, ° ..... : 2 FLOOR AREAS- - - - --- ,BASEMENT...: 0 sf REQUIRED SETBACKS - - -- REQUIRED------- - --
CLASS OF WORK.:NEW HEIGHT........:: 23 FIRST • 1198 Si GARAGE • 651 sf LEFT, : 6 SMOKE DETECTRS: Y
TYPE OF USE... :SF FLOOR LOAD • 40 SECOND...: 961 sf FRONT : 20 PARKING SPACES: 1
TYPE OF CONST.:5N DWELLING UNITS: 1, . FINBSMENT::. 0 sf RIGHT : 5
OCCUPANCY GRP.:R3 BDRM: 4 BATH: 3 TOTAL - -: 2159 sf VALUE..$: 155947 REAR • 41
- -------------------- - - -- -- - - ---.- PLUMBING — .- - -- - - ----
SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 0 TRAPS : 0
LAVATORIES • 4 DISHWASHERS... :. 1 FLOOR DRAINS..:-._ 0... SEWER LINE ft.: 0 . SF RAIN DRAINS: 1 CATCH BASINS..: 0
TUB /SHOWERS...: 3 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 100 BCKFLW PREVNTR: 1 GREASE TRAPS..: 0
OTHER FIXTURES: 0
- - - - - -- — - MECHANICAL — ----------------------------- - --
FUEL TYPES--- ---- -, FURN :.(r100K ..1. .0 BOIL /CMP : ( 3HP:' 0'. VENT FANS 4. CLOTHES .DRYERS: 1.,
/GAS/ / / FURN ) =100K ..: 1 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1
MAX INP.: 0—BTU. FLOOR FURNACES: 0., VENTS ° 0. WOODSTOVES.....: 0 . GAS OUTLETS...:: 1 • ,
- - - -- -- ---- -- - -- - -- ELECTRICAL -
- - RESIDENTIAL UNIT -- -- SERVICE /FEEDER -- -TEMP SRVC /FEEDERS- — BRANCH CIRCUITS - -- --- MISCELLANEOUS ---- - -ADD'L INSPECTIONS- -
1m SF OR LESS: 1 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
EA ADD'L 500SF.: 4 201.- 400 aap..: 0 • 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR : 0
LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 6v, amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0
MANF HM /SVC /FDR: 0 601 - 1000 amp.: 0' 601 +amps- 10v v: 0 . MINOR LABEL -10: 0
1000+ amp /volt.: 0 — PLAN REVIEW SECTION --------------- --- --
Reconnect only.: V' ) =4 RES UNITS..:.. SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC OCC:
- ---- - - - - -- - -- ELECTRICAL - RESTRICTED ENERGY - - - -- ----- - - - - -- - --
A. SF RESIDENTIAL ----- ---- - --- - - - - - -. . B. COMMERCIAL ---- — - ----------------- -- - - -- - - - - - --
AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM. -.:. OTH:;. , , ,. X!,..:... BOILER ., • HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL:.
GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICAL OTHR: ••
HVAC . . , DATA /TELE COMM.: • . . • NURSE CALLS • TOTAL # SYSTEMS: 0
Owner: -----------------------------------Contractor: ----------------------------- TOTAL FEES:$ 4244.50
LEGEND HOMES LEGEND HOMES CORPORATION ,
6900 SW HAINES 7160 SW HAZELFERN RD.
SUITE 100.
TIGARD OR 97223 TIGARD OR 97224
Phone #: 620 -8080 • . ., Phone #: 620 - 8080.,.
Reg #..: 60563
This permit. is issued subject to the, regulations. contained in the Tigard Municipal, Code,, State of Ore. Specialty Codes and all other
applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180
days of issuance, or if work is suspended for more than-180 days.
- -------------------------------------------------------- REQUIRED INSPECTIONS ------------ - - - - -- - - - -- - ---
Erosion Canto' Post /Beam Meehan. • Electrical. Serv.i : Fireplace Insp Rain drain Insp Mechanical Final
Grading Inspecti Crawl Drain Electrical Rough Gas Line Insp Water Line Insp Plumb Final
Footing Insp PLM /Underfloor Framing Insp bas Fireplace Water Service In Building Final
Foundation Insp Mechanical Insp Shear Wall Insp Insulation Insp Appr /Sdwlk Insp
Post /Beam Struct. , Plumb Top Out. , Lo • lta e,.... Board..Insp . ,,, e ical Final
Permittee Signature: °�� fj � ',. � -� sued ds,k
/ iv./
Cal f•inspection - E39 -4175,
- - - - - - - - - - . • , , - --
�� /
Plan Check # (- 61 1.
:ITY OF TIG.ARD Residential Building Permit Application d By'
3125 SW HALL BLVD. New Construction Additions or Alterations Date Rec'd /03096
'IGARD, OR 97223 Single Family Detached or Attached -kr, Date to P.E. 12
503) 639 -4171 '\� Date to DST
Print or Type Pi Permit # 1 - OgSb
Called 1-747 Co k, ')6-5513
Incomplete or illegible applications will not be accepted a . ,, . ,u, 2.0
V _. .. —
Name of Subdivision Lot # Name
Job HUNTER'S GLEN 16 LEGEND HOMES
S ite A ress
Address Architect Mailing Address •
127 SW 116th Avenue 6900 SW Haines St. •
Name City /State Zip Phone
LEGEND HOMES Tigard, OR 97223 620 -8080
Owner Mailing Address Name
6900 SW Haines St. FROELICH
City /State
Zip Phone En Mailing Address
Tigard, OR 97223 620 -8080 6969 SW Hampton St.
City /State Zip Phone
Name Tigard, OR 97223 624 -7005
General LEGEND HOMES Describe work ne addition 0 alteration 0 repair 0
Contractor Mailing Address to be done:
6900 S W Haines St. • Additional Description of Work:
City/State Zip Phone
Tigard, OR 97223 620 -8080
Oregon Const. Cont. Board Lic.# Exp. Date
Attach Copy of 060563 6/ 19 / 9 7 Project <_
Current I ��71 --
COT Busines�Tax�r Metro Exp. Date Valuation �� .. ?
Licenses _- GG�� oo CC /f'j 3 NEW CONSTRUCTION ONLY:
Name / J /.2 / /��/
Mechanical SUNGLOW INC. Sq.Ft. Hous /S Sq.Ft.Gage:
Sub- Mailing Address ( � (
Contractor ; 2428 S E 105th Corner Lot . . Yes No Flag Lot �, Yes No
City/State Zip Phone (check one) l _ C' (check on-e) ��
Portland, OR 9721E1,253-7789 Restricted Audio /Stereo /0 Burglar
Oregon Const. Cent. Board Lic.# Exp. Date Energy System Alarm
Attach Copy of ; 48131 Hi- th an, :57-? O 7 Installation p Garage Door HVAC
Current COT Business Tax or Metro • Exp. it ate 11
Licenses ( 3,.2-6 ��- �r41*J -- jr" Opener Systems
Name (check all that Other:
Plumbing i WOLCOTT PLUMBING apply)
Sub '.!ailing Address Will the electrical subcontractor wire for all Yes No
Contractor P O Box 2007 restricted energy installations?
City/State Zip Phone Has the Subdivision Plat recorded? N/A X No
Gresham, OR 97030 667 =9891
Oregon Const. Cont. Board Lic.# Exp. Date Reissue of MST# Solar Compliance
Attach Copy of 7 3g 47 10/19/97 '7 Q / (Calculation Attached)
Current Plumbing Lic. # Exo. Date I hereby acknowledge that I have read this application, that the
Licenses 2 6 - 2 0 8 P B 8/31/97 information given is correct, that I am the owner or authorized agent of
COT Business Tax or Metro # Exp. Date the owner, and that plans submitted are in compliance with Oregon
96 -4281 12/96 State laws.
Name Signae of Own Date
Electrical GARNER ELECTRIC `�
Con t Perso Nam � Pe
Sub- Mailing Address / 6P i 2
Contractor 21785 SW TV Highwa FO O Flu SE ONLY:
City/State Zip Phone Plat # MapITL #:
Aloha, OR 97006 591 -1320 t Ci �/
Oregon Cons . C nt Board Lic.# Exp. Date C O S - L v `1 6-D 2( 36i)- 1 42
Attach Copy of 74-8-9-6- f � , ..,42Z/
a/q l � Setbacks Zone: Solar. Current Electrical Lic. # Da e Q I
Licenses 34-305C /%/ / 7 - (o/P/ V g- y, � �7
COBusiness ; Metro a # fa e ,�.� T� Engineering Approval: � Pla ' n g Approval: TIP:
sts\mstapp.doc S1 r f p
r (2-3/-16
Permit # Account Description Amount Amt. Pd. Bal. Due
1051 iG _ossc , MST. Permit (BUILD) .573. ' / f751 cu
Plumb. Permit (PLUMB) a .2 S V. 2 i '`
3 c..�+
Mech. Permit (MECH) zip, car,
Ca
ELC /ELR Permit
( ERPRMT) DSO. ` V 02,576.
State Tax (TAX) s c1 . c. S / 5 CI'
,
Bldg: „z E?• /
Plumb: /if L 5
Mech: ..2. L ,
ELC /ELR: f 2. 1 - 0 /
Plan Check
MST: $o f .Z /' 4:- (BUPPLN) //l ` J �� 7 1 .-C)
Plumb: (PLMPLN)
1Vlech: CSC (MECPLN) //- 2.C /- '
//- Z
CDC Review c -P ` (LANDUS) �/0. --\// -
c 5u/R.K. o57.3 Sewer Connection (SWUSA) a2 �u ' , oxa G
Sewer Inspection (SWINSP) Sr 3i
Parks Dev Charge (PKSDC) /0 sti' i /v ,rte
Residential TIF (TIF -R) /67t) /S
Mass Transit TIF (TIF -MT) /2-v / / Z-e
Water Quality (WQUAL)
Water Quantity (WQUANT) / v d //‘ :s
Erosion Control Permit (ERPRMT) 6c/ (- "/
v
Erosion Planck/USA (ERPLAN) 0 .1-0- 151 -' ,,-77.-
Erosion Planck/COT (EROSN) Pv °
Fire Life Safety (FLS)
TOTALS: (o y 7 Ft. So C C. y c 2j . 5 ;1)
i:ldstslmstapp.doc
Rev. 7/96
A. B la i - P • nt . I ard W 8 rkilieet-- • • .
. . ,
Address - 7 /7 5af 7/6 igue Zo '
Box A calculations: North-South n --- " - a l . ^EirmIsi rforttrelot Box A: .
. ‘ , ... \
This dimension is determined by finding the midpoint of the North lot line and drawing .
an inter line perpendicular to that point.
First, determine which property line is the North lot line. TheNorth line is the line
with the smallest angle from a line drawn east-west and intersecting the northern most /
point of the lot.
.--
45 -- •
I
NOMHERN NCERHOIN
LOT UNE 1.01 UP*
.. - N .::- - , ..' -_, - :nil , (".Y . .. ..: - .' - -i - i . North-South
Dimension for Lot:
i
, .
Measure the distance from the midpoint of the North lot line to the South lot linealong - ----,
the described line. , feet
:
. ._
,,.. - .., - ., ,, <3==NOR1H-SOUN 011.46190N .--0.- " -•', :% .' - • ,"... ' v• -. - A ; ' : .-";+ '.' ,
. i — ' . - ,, ' A 3 • ... ' ' * / -." 4. . '''' ''' ' R .
.,.. .-.. ... . - •
e
• ' . ' 1
; o' •- '' '$4 .:-. 7 .; '; ' ''. -; '2 i . , ' ;.0. P-qt1) .
Box B calculations: Shade point height for your residence: --- —.. -- - - -- - —
Box B:
1. Determine whether measurements will be based on the peak or eave of your
i
structure. The orientation of the ridge is also important. Which describes
your residence?
la: If the roof line runs North-South, measurements will (circle One) . -
l'■ i
be based on the peak of the roof. _ - , 1:1013a
maim,
1A 1 B 1C 1
---
4$C
1 b: If the roof line runs East-West and the roof pitch is
less than 5/12, measurements'will be based on the
1 h 4 linal Illah
eave.
SHAM FON!' EMS
- .
' 1 c: If the roof line runs East-West and the roof pitch is
5i12 or steeper, measurements will be based on the . tig Rod . i ,
peak. - - - .
OWN PPM RON
,. . ,. , . ..... .......,- .....,..... ,, ,., ,,,....... ,,,- 4
. ..., . '. 1
. ..„...... ..-,-,,,. - ''..1
`. Alitioix,
. �.
Box B. continued r .. , Y ` . Box B:
2. Measure change in elevation from front property line to finished floor elevation. If
the lot slopes up from the front lot line to the foundation, the figure is positive. If ft "
• the lot slopes down from the front lot line to the foundation, the figure 'is negative. \ .
; i
3., Measure distance
from finished floor elevation to the affected peak/eave. + ft . ,
: ft
4. If the roof line runs North - South, deduct three feet. If the roof line runs East - West, - •
deduct nothing- , �,
5. Subtract one foot for each foot of difference in elevation from the front property
line to the rear property line, if the lot slopes up from the front to the rear. If the
lot has no slope or slopes up from the rear to the front, deduct nothing. - ft
6. Total figure for box B: - ft
Box C. Distance to the shade reduction line. .. .. Box C:
1. Measure the distance from the North property line to the foundation near the ft '17.!
affected peak/eave. I t
`
2. Measure the distance from the foundation to the affected peak or eave. '.'.::.`:. :` r k':i =s ti. :eft FF
3. Total figure for box C: ft
t
It is most useful to draw a vertical line to represent the appropriate figure f in box "A" and a ho " tal line to represent the a
appropriate figure found in box "C ". The intersection of the vertical and horizontal lines determines the • e• slue found in box "D ". The value €
in box "D" should be compared to the value in box "B "; if the value'iri box is less than or equal to : value found in box "D ", then
the building is in compliance with the solar balance code. If you have any questions, please contact us at 639 -4171, x304 or at the
Community Development Counter. a
[ • • MAXIMUM PERMITTED SHADE POINT HEIGHT (In Feet) 1 _ _ .
Distance to North -south lot dimension (in f eet)
• shade 0 100+ .95 90 85 80 75 .70 65 60 55:50 45 .40
• reduction line :'`
from northern
Jot line (in feet)
70 40 40 40 41 42 43 44 i..
• 65 38 . _ 38 38 39 40 41 42 43 0
60 36 36 36 37 . 38 39 40 41 42
55 34 34 34 35 36 37 38 39 40 41 .
50 32 32 32 33 34 35 36 37 38 39 40
45 30 30 30 31 32 33 _34 36 37 38 39
40 28 28 28 29 30 31 32 33 34 ; 35 , 36 37 38
35 26 26 26 27 28 29 30 31 32 33 34 35 36
• 30 24 24 24 25 26 27 28 29 30 31 32 33 34
•
25 i 22 22 22 23 24 25 26 27 28 29 30 31 32
20 • 20 20 20 21 22 23 24 25 26 27 28 29 30
15 18 18 18 19 20 21 22 23 24 25 26 27 28
10 16 16 16 17 18 19 20 21 22 23 24 25 26 t`
5 14 14 14 15 16 17 18 19 20 -21 22 23 24
I Box D. Maximum allowed shade point height: feet
I �
hAdocs\nancywenturalsolar.chp .,..... .... .. - ._.... .. ...
Revised 2/26/96 `._
CITY OF TIGARD BUILDING INSPECTION DIVISION
• 24 -Hour Inspection Line: 639 -4175 Business Phone: 639 -4171
Date Requested: //__ (% / A . M . ` ' P.M. MST: /''' 0 55
Location: 4.2-7/ 5 2 Sa 1/ 6 iLl- Al tre-- LOT/ BUP:
Tenant: Suite: Bldg: MEC:
Contractor: Phone: �� .s7 PLM:
Owner: Phone: ELC:
ELR:
SIT:
BUILDING BLDG (con't) PLUMBING MECHANICAL ELECTRICAL SITE
Site Post/Beam .':✓.1 Post/Beam Cover /Service Sewer /Storm
Footing Roof UndFl/Slab Rough -In Ceiling Water Line
Slab Framing Top Out Gas Line Rough -In UG Sprinlder
Foundation Insulation Sewer Hood/Duct Reconnect Vault
Bsmt Damp Drywall Storm Furnace Temp Service MISC.
Masonry Ceiling Rain Drain A/C UG Slab
Shear /Sheath Fire Spklr /Alm Crawl/Found Dr Heat Pump Low Volt
Approved Approved Approved Approved Approved
Appr /Sdwlk Not Approved oved Not Approved • Not Approved Not Approved
FINAL ( FINAL FINAL FINAL
i
Mawr . I .
\i
tr (
2 .... _ I .
k I\
O Call for reinspection 0 Reinspection fee of $ required before next inspection 0 Unable to inspect
Inspector:
Z Date: / ') Page / of j
05/30/2000 Activities for Case #: MST96 -00556 EXPIRED
11:46:53 AM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA005 Application received 12/30/1996 JH RECD PHN 12/31/1996
MSTA008 Permit Created 12/31/1996 B PEND PHN 12/31/1996
MSTA010 Check for prcl. restrict. 12/30/1996 PHN 12/31/1996
MSTA012 Plans routed to Plans Examiner 12/31/1996 B PEND PHN 12/31/1996
MSTA026 Plans approved by RPE 01/06/1996 RT PASS BT2 01/06/1997
MSTA030 Reviewed plans routed to DSTS 01/06/1996 RT PASS BT2 01/06/1997
MSTA032 DST Post - Review Completed 01/07/1997 DRA PASS DST 01/07/1997
MSTA700 Erosion Control Insp 844 -8444 PHN 12/31/1996
MSTA703 Grading Inspection PHN 12/31/1996
MSTA705 Footing Insp 02/05/1997 KS APP KBS 02/06/1997 _ .
MSTA706 Foundation Insp 02/06/1997 GS APP GES 02/06/1997
MSTA710 Post/Beam Structural 02/14/1997 KS APP KBS 02/18/1997
MSTA711 Post/Beam Mechanical 02/14/1997 KS APP KBS 02/18/1997
MSTA713 Crawl Drain PHN 12/31/1996
MSTA717 PLM /Underfloor 02/14/1997 MS PASS MRS 02/18/1997
MSTA720 Mechanical Insp 04/01/1997 RB FAIL RB 04/02/1997 see framing this date
MSTA722 Plumb Top Out PHN 12/31/1996
MSTA723 Electrical Service 03/27/1997 MJR PASS MJR 03/31/1997
MSTA724 Electrical Rough In 03/27/1997 MJR PASS MJR 03/31/1997 paddle fan in family and M.
bedroom
Page 1 of 4
05/30/2000 Activities for Case #: MST96 -00556 EXPIRE
11:46:53 AM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA725 Framing Insp 04/01/1997 RB FAIL RB 04/02/1997 gas line test; soffit heat duct in
garage; exhaust venting
disconnected; insulate duct
above ceiling in attic; firestop at
ceiling /floor level for B -vent
chase; strap plate -to -beam in
L.R.; add stud over header
between dining /kitchen; add
nails in hanger at nook; strap
plate 2x4 to 2x6 wall behind
garage; support notched studs
behind furnace; attic access
needed for garage; starp
glu -lam in master bedrm;
laminate studs at base of stairs;
strap glu -lam at stairs;
re- support bored out floor joist
in garage ; side nail hanger at
post in garage; provide stud at
rear wall of garage at 3"
sanitary line- support floor
above.
MSTA726 Shear Wall Insp 03/14/1997 KS N/R KBS 03/14/1997 #-1- canceled by request
MSTA727 Low Voltage PHN 12/31/1996
MSTA735 Gas Line Insp 04/01/1997 RB FAIL RB 04/02/1997 low pressure for test
MSTA736 Gas Fireplace PHN 12/31/1996
MSTA740 Insulation !asp 04/10/1997 KS APP KBS 04/11/1997
MSTA745 Gyp Board Insp 04/16/1997 KS APP KBS 04/17/1997
MSTA755 Rain drain Insp 02/10/1997 MS PASS MRS 02/11/1997
MSTA761 Water Service Insp 02/10/1997 MS PASS MRS 02/11/1997
MSTA765 Appr /Sdwlk Insp 04/15/1997 LT PASS RB 04/16/1997 1. PLACE BOARDS FOR
WINGS. 2. BE PREPARED TO
PROTECT FINISH.
MSTA790 Electrical Final 06/06/1997 BRP PASS J *H 06/06/1997
MSTA795 Mechanical Final 06/12/1997 RB FAIL J *H 09/16/1997
•
MSTA•97 Plumb Final 06/06/1997 MS PASS J *H 06/09/1997
Page 2 of 4
05/30/2000 Activities for Case #: MST96 -00556
11:46:53 AM
EXPIRE
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA799 Building Final 06/10/1997 RB FAIL J *H 06/12/1997 1. Seal range vent within
cabinet. 2. Gas connector and
shut off missing at fireplace
within family room. 3.
Weatherstrip main door. 4.
Bottom stepping in straight run
should be greater than 3/8"
variance. this is not a winder
staircase, design flaw. 5. Cap
rear yard rain drain. 6. AC unit
amp 24/24 min (30/30), max
40/40 10 Seer Rheem. 7. Do
you have a sprinkler permit
signoff? 8. Post address. 9.
CALL FOR REINSPECTION.
MSTA080 (F) Ready to issue 01/07/1997 DRA PASS DRA 01/07/1997 Needs renewal for Tigard Bus
Tax on Wolcott.
MSTA092 (F) Issue combination permit 01/30/1997 DRA PASS DRA 01/30/1997
MSTA095 Issue plumbing signature form 02/06/1997 DRA PASS RB 02/06/1997 RECD SIGN FORM 2 -5 -97
MSTA097 Issue electric signature form 02/10/1997 DRA PASS KAS 02/10/1997 Recd sign form back 2- 10 -97.
MSTA726 Shear Wall lnsp 03/19/1997 GS APP GES 03/19/1997 corrections on jobsite card left
by ks are appr
MSTA726 Shear Wall Insp 03/18/1997 KS DIS KBS 03/31/1997 #-1- HTT holdowns missed at
garage wing walls, nail panel
at 3/12 o/c #-2- nail panel #-4-
6/12 o/c #-3- mst straps missed
at rear of structure #-4- nail
generic panels at 6/12 o/c
MSTA735 Gas Line Insp 04/04/1997 KS DIS KBS 04/07/1997 #-1- pressure not adequate for
test
MSTA725 Framing Insp 04/04/1997 KS DIS KBS 04/07/1997 #-5- support thermostat wire top
of fireplace #-6- insulate entire
heat ducts at garage
MSTA720 Mechanical lnsp 04/07/1997 KS APP KBS 04/08/1997
MSTA725 Framing lnsp 04/07/1997 KS APP KBS 04/08/1997
MSTA735 Gas Line Insp 04/08/1997 KS DIS KBS 04/10/1997 #-1- won't hold pressure
MSTA735 Gas Line Insp 04/09/1997 KS DIS KBS 04/10/1997 #-1- won't hold pressure
MSTA735 Gas Line Insp 04/14/1997 KS APP KBS 04/15/1997 #-1- gas piping pt test= 30 psi
for twenty minutes
Page 3 of 4
05/30/2000 Activities for Case #: MST96 -00556
11:46:53 AM EXPIRED
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA799 Building Final 06/12/1997 RB FAIL J *H 09/16/1997 Bldg. final held over until
decision regarding stepping
determined. Jim Funk and Bob
Poskin have determined that
the State of Oregon will need to
provide and alternate
interpretation to allow stepping
as built at the present time.
See file, interpretation did not
result in allowance of the
alternate stepping as built.
Stepping needs to be corrected.
MSTA799 Building Final VLN NOTE VLN 03/10/1999 Inspection request for research
to George S. 3110/99.
MSTA945 Request inspection research 03/27/2000 JMT DONE No Hold JMT 03/27/2000 SECOND REQUEST
MSTA153 Expired by limitation 04/18/2000 HAP DONE No Hold AKJ 04/26/2000 card sent to contractor
•
Page 4 of 4