Permit • f CITY OF TIGARD „,,,, ; DEVELOPMENT SERVICES MASTER PERMIT PERMIT #° ° ° ° ° . ° : MST96 -0556 13125 SW HaII Blvd., Tigard, OR 97223 (503)639-4171 DATE ISSUED: 01/30/97 ,` PARCEL: 2S103BD -HG016 SITE ADDRESS...: 1274 - SW 116TH AVE SUBDIVISION-.....: HUNTER'' LOT . � i 6 LEN • EXPIR JN I NG : R-4.5 PD BLOCK..........: Remarks: Path 1 - -- --------------- - ----- - - -- -- BUILDING --------------- ---- - - -- - -- - --- -- - --- -- ---- ---- REISSUE:MST96 -0462 STORIES, ° ..... : 2 FLOOR AREAS- - - - --- ,BASEMENT...: 0 sf REQUIRED SETBACKS - - -- REQUIRED------- - -- CLASS OF WORK.:NEW HEIGHT........:: 23 FIRST • 1198 Si GARAGE • 651 sf LEFT, : 6 SMOKE DETECTRS: Y TYPE OF USE... :SF FLOOR LOAD • 40 SECOND...: 961 sf FRONT : 20 PARKING SPACES: 1 TYPE OF CONST.:5N DWELLING UNITS: 1, . FINBSMENT::. 0 sf RIGHT : 5 OCCUPANCY GRP.:R3 BDRM: 4 BATH: 3 TOTAL - -: 2159 sf VALUE..$: 155947 REAR • 41 - -------------------- - - -- -- - - ---.- PLUMBING — .- - -- - - ---- SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 0 TRAPS : 0 LAVATORIES • 4 DISHWASHERS... :. 1 FLOOR DRAINS..:-._ 0... SEWER LINE ft.: 0 . SF RAIN DRAINS: 1 CATCH BASINS..: 0 TUB /SHOWERS...: 3 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 100 BCKFLW PREVNTR: 1 GREASE TRAPS..: 0 OTHER FIXTURES: 0 - - - - - -- — - MECHANICAL — ----------------------------- - -- FUEL TYPES--- ---- -, FURN :.(r100K ..1. .0 BOIL /CMP : ( 3HP:' 0'. VENT FANS 4. CLOTHES .DRYERS: 1., /GAS/ / / FURN ) =100K ..: 1 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1 MAX INP.: 0—BTU. FLOOR FURNACES: 0., VENTS ° 0. WOODSTOVES.....: 0 . GAS OUTLETS...:: 1 • , - - - -- -- ---- -- - -- - -- ELECTRICAL - - - RESIDENTIAL UNIT -- -- SERVICE /FEEDER -- -TEMP SRVC /FEEDERS- — BRANCH CIRCUITS - -- --- MISCELLANEOUS ---- - -ADD'L INSPECTIONS- - 1m SF OR LESS: 1 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 4 201.- 400 aap..: 0 • 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR : 0 LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 6v, amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0 MANF HM /SVC /FDR: 0 601 - 1000 amp.: 0' 601 +amps- 10v v: 0 . MINOR LABEL -10: 0 1000+ amp /volt.: 0 — PLAN REVIEW SECTION --------------- --- -- Reconnect only.: V' ) =4 RES UNITS..:.. SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC OCC: - ---- - - - - -- - -- ELECTRICAL - RESTRICTED ENERGY - - - -- ----- - - - - -- - -- A. SF RESIDENTIAL ----- ---- - --- - - - - - -. . B. COMMERCIAL ---- — - ----------------- -- - - -- - - - - - -- AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM. -.:. OTH:;. , , ,. X!,..:... BOILER ., • HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL:. GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICAL OTHR: •• HVAC . . , DATA /TELE COMM.: • . . • NURSE CALLS • TOTAL # SYSTEMS: 0 Owner: -----------------------------------Contractor: ----------------------------- TOTAL FEES:$ 4244.50 LEGEND HOMES LEGEND HOMES CORPORATION , 6900 SW HAINES 7160 SW HAZELFERN RD. SUITE 100. TIGARD OR 97223 TIGARD OR 97224 Phone #: 620 -8080 • . ., Phone #: 620 - 8080.,. Reg #..: 60563 This permit. is issued subject to the, regulations. contained in the Tigard Municipal, Code,, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than-180 days. - -------------------------------------------------------- REQUIRED INSPECTIONS ------------ - - - - -- - - - -- - --- Erosion Canto' Post /Beam Meehan. • Electrical. Serv.i : Fireplace Insp Rain drain Insp Mechanical Final Grading Inspecti Crawl Drain Electrical Rough Gas Line Insp Water Line Insp Plumb Final Footing Insp PLM /Underfloor Framing Insp bas Fireplace Water Service In Building Final Foundation Insp Mechanical Insp Shear Wall Insp Insulation Insp Appr /Sdwlk Insp Post /Beam Struct. , Plumb Top Out. , Lo • lta e,.... Board..Insp . ,,, e ical Final Permittee Signature: °�� fj � ',. � -� sued ds,k / iv./ Cal f•inspection - E39 -4175, - - - - - - - - - - . • , , - -- �� / Plan Check # (- 61 1. :ITY OF TIG.ARD Residential Building Permit Application d By' 3125 SW HALL BLVD. New Construction Additions or Alterations Date Rec'd /03096 'IGARD, OR 97223 Single Family Detached or Attached -kr, Date to P.E. 12 503) 639 -4171 '\� Date to DST Print or Type Pi Permit # 1 - OgSb Called 1-747 Co k, ')6-5513 Incomplete or illegible applications will not be accepted a . ,, . ,u, 2.0 V _. .. — Name of Subdivision Lot # Name Job HUNTER'S GLEN 16 LEGEND HOMES S ite A ress Address Architect Mailing Address • 127 SW 116th Avenue 6900 SW Haines St. • Name City /State Zip Phone LEGEND HOMES Tigard, OR 97223 620 -8080 Owner Mailing Address Name 6900 SW Haines St. FROELICH City /State Zip Phone En Mailing Address Tigard, OR 97223 620 -8080 6969 SW Hampton St. City /State Zip Phone Name Tigard, OR 97223 624 -7005 General LEGEND HOMES Describe work ne addition 0 alteration 0 repair 0 Contractor Mailing Address to be done: 6900 S W Haines St. • Additional Description of Work: City/State Zip Phone Tigard, OR 97223 620 -8080 Oregon Const. Cont. Board Lic.# Exp. Date Attach Copy of 060563 6/ 19 / 9 7 Project <_ Current I ��71 -- COT Busines�Tax�r Metro Exp. Date Valuation �� .. ? Licenses _- GG�� oo CC /f'j 3 NEW CONSTRUCTION ONLY: Name / J /.2 / /��/ Mechanical SUNGLOW INC. Sq.Ft. Hous /S Sq.Ft.Gage: Sub- Mailing Address ( � ( Contractor ; 2428 S E 105th Corner Lot . . Yes No Flag Lot �, Yes No City/State Zip Phone (check one) l _ C' (check on-e) �� Portland, OR 9721E1,253-7789 Restricted Audio /Stereo /0 Burglar Oregon Const. Cent. Board Lic.# Exp. Date Energy System Alarm Attach Copy of ; 48131 Hi- th an, :57-? O 7 Installation p Garage Door HVAC Current COT Business Tax or Metro • Exp. it ate 11 Licenses ( 3,.2-6 ��- �r41*J -- jr" Opener Systems Name (check all that Other: Plumbing i WOLCOTT PLUMBING apply) Sub '.!ailing Address Will the electrical subcontractor wire for all Yes No Contractor P O Box 2007 restricted energy installations? City/State Zip Phone Has the Subdivision Plat recorded? N/A X No Gresham, OR 97030 667 =9891 Oregon Const. Cont. Board Lic.# Exp. Date Reissue of MST# Solar Compliance Attach Copy of 7 3g 47 10/19/97 '7 Q / (Calculation Attached) Current Plumbing Lic. # Exo. Date I hereby acknowledge that I have read this application, that the Licenses 2 6 - 2 0 8 P B 8/31/97 information given is correct, that I am the owner or authorized agent of COT Business Tax or Metro # Exp. Date the owner, and that plans submitted are in compliance with Oregon 96 -4281 12/96 State laws. Name Signae of Own Date Electrical GARNER ELECTRIC `� Con t Perso Nam � Pe Sub- Mailing Address / 6P i 2 Contractor 21785 SW TV Highwa FO O Flu SE ONLY: City/State Zip Phone Plat # MapITL #: Aloha, OR 97006 591 -1320 t Ci �/ Oregon Cons . C nt Board Lic.# Exp. Date C O S - L v `1 6-D 2( 36i)- 1 42 Attach Copy of 74-8-9-6- f � , ..,42Z/ a/q l � Setbacks Zone: Solar. Current Electrical Lic. # Da e Q I Licenses 34-305C /%/ / 7 - (o/P/ V g- y, � �7 COBusiness ; Metro a # fa e ,�.� T� Engineering Approval: � Pla ' n g Approval: TIP: sts\mstapp.doc S1 r f p r (2-3/-16 Permit # Account Description Amount Amt. Pd. Bal. Due 1051 iG _ossc , MST. Permit (BUILD) .573. ' / f751 cu Plumb. Permit (PLUMB) a .2 S V. 2 i '` 3 c..�+ Mech. Permit (MECH) zip, car, Ca ELC /ELR Permit ( ERPRMT) DSO. ` V 02,576. State Tax (TAX) s c1 . c. S / 5 CI' , Bldg: „z E?• / Plumb: /if L 5 Mech: ..2. L , ELC /ELR: f 2. 1 - 0 / Plan Check MST: $o f .Z /' 4:- (BUPPLN) //l ` J �� 7 1 .-C) Plumb: (PLMPLN) 1Vlech: CSC (MECPLN) //- 2.C /- ' //- Z CDC Review c -P ` (LANDUS) �/0. --\// - c 5u/R.K. o57.3 Sewer Connection (SWUSA) a2 �u ' , oxa G Sewer Inspection (SWINSP) Sr 3i Parks Dev Charge (PKSDC) /0 sti' i /v ,rte Residential TIF (TIF -R) /67t) /S Mass Transit TIF (TIF -MT) /2-v / / Z-e Water Quality (WQUAL) Water Quantity (WQUANT) / v d //‘ :s Erosion Control Permit (ERPRMT) 6c/ (- "/ v Erosion Planck/USA (ERPLAN) 0 .1-0- 151 -' ,,-77.- Erosion Planck/COT (EROSN) Pv ° Fire Life Safety (FLS) TOTALS: (o y 7 Ft. So C C. y c 2j . 5 ;1) i:ldstslmstapp.doc Rev. 7/96 A. B la i - P • nt . I ard W 8 rkilieet-- • • . . . , Address - 7 /7 5af 7/6 igue Zo ' Box A calculations: North-South n --- " - a l . ^EirmIsi rforttrelot Box A: . . ‘ , ... \ This dimension is determined by finding the midpoint of the North lot line and drawing . an inter line perpendicular to that point. First, determine which property line is the North lot line. TheNorth line is the line with the smallest angle from a line drawn east-west and intersecting the northern most / point of the lot. .-- 45 -- • I NOMHERN NCERHOIN LOT UNE 1.01 UP* .. - N .::- - , ..' -_, - :nil , (".Y . .. ..: - .' - -i - i . North-South Dimension for Lot: i , . Measure the distance from the midpoint of the North lot line to the South lot linealong - ----, the described line. , feet : . ._ ,,.. - .., - ., ,, <3==NOR1H-SOUN 011.46190N .--0.- " -•', :% .' - • ,"... ' v• -. - A ; ' : .-";+ '.' , . i — ' . - ,, ' A 3 • ... ' ' * / -." 4. . '''' ''' ' R . .,.. .-.. ... . - • e • ' . ' 1 ; o' •- '' '$4 .:-. 7 .; '; ' ''. -; '2 i . , ' ;.0. P-qt1) . Box B calculations: Shade point height for your residence: --- —.. -- - - -- - — Box B: 1. Determine whether measurements will be based on the peak or eave of your i structure. The orientation of the ridge is also important. Which describes your residence? la: If the roof line runs North-South, measurements will (circle One) . - l'■ i be based on the peak of the roof. _ - , 1:1013a maim, 1A 1 B 1C 1 --- 4$C 1 b: If the roof line runs East-West and the roof pitch is less than 5/12, measurements'will be based on the 1 h 4 linal Illah eave. SHAM FON!' EMS - . ' 1 c: If the roof line runs East-West and the roof pitch is 5i12 or steeper, measurements will be based on the . tig Rod . i , peak. - - - . OWN PPM RON ,. . ,. , . ..... .......,- .....,..... ,, ,., ,,,....... ,,,- 4 . ..., . '. 1 . ..„...... ..-,-,,,. - ''..1 `. Alitioix, . �. Box B. continued r .. , Y ` . Box B: 2. Measure change in elevation from front property line to finished floor elevation. If the lot slopes up from the front lot line to the foundation, the figure is positive. If ft " • the lot slopes down from the front lot line to the foundation, the figure 'is negative. \ . ; i 3., Measure distance from finished floor elevation to the affected peak/eave. + ft . , : ft 4. If the roof line runs North - South, deduct three feet. If the roof line runs East - West, - • deduct nothing- , �, 5. Subtract one foot for each foot of difference in elevation from the front property line to the rear property line, if the lot slopes up from the front to the rear. If the lot has no slope or slopes up from the rear to the front, deduct nothing. - ft 6. Total figure for box B: - ft Box C. Distance to the shade reduction line. .. .. Box C: 1. Measure the distance from the North property line to the foundation near the ft '17.! affected peak/eave. I t ` 2. Measure the distance from the foundation to the affected peak or eave. '.'.::.`:. :` r k':i =s ti. :eft FF 3. Total figure for box C: ft t It is most useful to draw a vertical line to represent the appropriate figure f in box "A" and a ho " tal line to represent the a appropriate figure found in box "C ". The intersection of the vertical and horizontal lines determines the • e• slue found in box "D ". The value € in box "D" should be compared to the value in box "B "; if the value'iri box is less than or equal to : value found in box "D ", then the building is in compliance with the solar balance code. If you have any questions, please contact us at 639 -4171, x304 or at the Community Development Counter. a [ • • MAXIMUM PERMITTED SHADE POINT HEIGHT (In Feet) 1 _ _ . Distance to North -south lot dimension (in f eet) • shade 0 100+ .95 90 85 80 75 .70 65 60 55:50 45 .40 • reduction line :'` from northern Jot line (in feet) 70 40 40 40 41 42 43 44 i.. • 65 38 . _ 38 38 39 40 41 42 43 0 60 36 36 36 37 . 38 39 40 41 42 55 34 34 34 35 36 37 38 39 40 41 . 50 32 32 32 33 34 35 36 37 38 39 40 45 30 30 30 31 32 33 _34 36 37 38 39 40 28 28 28 29 30 31 32 33 34 ; 35 , 36 37 38 35 26 26 26 27 28 29 30 31 32 33 34 35 36 • 30 24 24 24 25 26 27 28 29 30 31 32 33 34 • 25 i 22 22 22 23 24 25 26 27 28 29 30 31 32 20 • 20 20 20 21 22 23 24 25 26 27 28 29 30 15 18 18 18 19 20 21 22 23 24 25 26 27 28 10 16 16 16 17 18 19 20 21 22 23 24 25 26 t` 5 14 14 14 15 16 17 18 19 20 -21 22 23 24 I Box D. Maximum allowed shade point height: feet I � hAdocs\nancywenturalsolar.chp .,..... .... .. - ._.... .. ... Revised 2/26/96 `._ CITY OF TIGARD BUILDING INSPECTION DIVISION • 24 -Hour Inspection Line: 639 -4175 Business Phone: 639 -4171 Date Requested: //__ (% / A . M . ` ' P.M. MST: /''' 0 55 Location: 4.2-7/ 5 2 Sa 1/ 6 iLl- Al tre-- LOT/ BUP: Tenant: Suite: Bldg: MEC: Contractor: Phone: �� .s7 PLM: Owner: Phone: ELC: ELR: SIT: BUILDING BLDG (con't) PLUMBING MECHANICAL ELECTRICAL SITE Site Post/Beam .':✓.1 Post/Beam Cover /Service Sewer /Storm Footing Roof UndFl/Slab Rough -In Ceiling Water Line Slab Framing Top Out Gas Line Rough -In UG Sprinlder Foundation Insulation Sewer Hood/Duct Reconnect Vault Bsmt Damp Drywall Storm Furnace Temp Service MISC. Masonry Ceiling Rain Drain A/C UG Slab Shear /Sheath Fire Spklr /Alm Crawl/Found Dr Heat Pump Low Volt Approved Approved Approved Approved Approved Appr /Sdwlk Not Approved oved Not Approved • Not Approved Not Approved FINAL ( FINAL FINAL FINAL i Mawr . I . \i tr ( 2 .... _ I . k I\ O Call for reinspection 0 Reinspection fee of $ required before next inspection 0 Unable to inspect Inspector: Z Date: / ') Page / of j 05/30/2000 Activities for Case #: MST96 -00556 EXPIRED 11:46:53 AM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA005 Application received 12/30/1996 JH RECD PHN 12/31/1996 MSTA008 Permit Created 12/31/1996 B PEND PHN 12/31/1996 MSTA010 Check for prcl. restrict. 12/30/1996 PHN 12/31/1996 MSTA012 Plans routed to Plans Examiner 12/31/1996 B PEND PHN 12/31/1996 MSTA026 Plans approved by RPE 01/06/1996 RT PASS BT2 01/06/1997 MSTA030 Reviewed plans routed to DSTS 01/06/1996 RT PASS BT2 01/06/1997 MSTA032 DST Post - Review Completed 01/07/1997 DRA PASS DST 01/07/1997 MSTA700 Erosion Control Insp 844 -8444 PHN 12/31/1996 MSTA703 Grading Inspection PHN 12/31/1996 MSTA705 Footing Insp 02/05/1997 KS APP KBS 02/06/1997 _ . MSTA706 Foundation Insp 02/06/1997 GS APP GES 02/06/1997 MSTA710 Post/Beam Structural 02/14/1997 KS APP KBS 02/18/1997 MSTA711 Post/Beam Mechanical 02/14/1997 KS APP KBS 02/18/1997 MSTA713 Crawl Drain PHN 12/31/1996 MSTA717 PLM /Underfloor 02/14/1997 MS PASS MRS 02/18/1997 MSTA720 Mechanical Insp 04/01/1997 RB FAIL RB 04/02/1997 see framing this date MSTA722 Plumb Top Out PHN 12/31/1996 MSTA723 Electrical Service 03/27/1997 MJR PASS MJR 03/31/1997 MSTA724 Electrical Rough In 03/27/1997 MJR PASS MJR 03/31/1997 paddle fan in family and M. bedroom Page 1 of 4 05/30/2000 Activities for Case #: MST96 -00556 EXPIRE 11:46:53 AM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA725 Framing Insp 04/01/1997 RB FAIL RB 04/02/1997 gas line test; soffit heat duct in garage; exhaust venting disconnected; insulate duct above ceiling in attic; firestop at ceiling /floor level for B -vent chase; strap plate -to -beam in L.R.; add stud over header between dining /kitchen; add nails in hanger at nook; strap plate 2x4 to 2x6 wall behind garage; support notched studs behind furnace; attic access needed for garage; starp glu -lam in master bedrm; laminate studs at base of stairs; strap glu -lam at stairs; re- support bored out floor joist in garage ; side nail hanger at post in garage; provide stud at rear wall of garage at 3" sanitary line- support floor above. MSTA726 Shear Wall Insp 03/14/1997 KS N/R KBS 03/14/1997 #-1- canceled by request MSTA727 Low Voltage PHN 12/31/1996 MSTA735 Gas Line Insp 04/01/1997 RB FAIL RB 04/02/1997 low pressure for test MSTA736 Gas Fireplace PHN 12/31/1996 MSTA740 Insulation !asp 04/10/1997 KS APP KBS 04/11/1997 MSTA745 Gyp Board Insp 04/16/1997 KS APP KBS 04/17/1997 MSTA755 Rain drain Insp 02/10/1997 MS PASS MRS 02/11/1997 MSTA761 Water Service Insp 02/10/1997 MS PASS MRS 02/11/1997 MSTA765 Appr /Sdwlk Insp 04/15/1997 LT PASS RB 04/16/1997 1. PLACE BOARDS FOR WINGS. 2. BE PREPARED TO PROTECT FINISH. MSTA790 Electrical Final 06/06/1997 BRP PASS J *H 06/06/1997 MSTA795 Mechanical Final 06/12/1997 RB FAIL J *H 09/16/1997 • MSTA•97 Plumb Final 06/06/1997 MS PASS J *H 06/09/1997 Page 2 of 4 05/30/2000 Activities for Case #: MST96 -00556 11:46:53 AM EXPIRE Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA799 Building Final 06/10/1997 RB FAIL J *H 06/12/1997 1. Seal range vent within cabinet. 2. Gas connector and shut off missing at fireplace within family room. 3. Weatherstrip main door. 4. Bottom stepping in straight run should be greater than 3/8" variance. this is not a winder staircase, design flaw. 5. Cap rear yard rain drain. 6. AC unit amp 24/24 min (30/30), max 40/40 10 Seer Rheem. 7. Do you have a sprinkler permit signoff? 8. Post address. 9. CALL FOR REINSPECTION. MSTA080 (F) Ready to issue 01/07/1997 DRA PASS DRA 01/07/1997 Needs renewal for Tigard Bus Tax on Wolcott. MSTA092 (F) Issue combination permit 01/30/1997 DRA PASS DRA 01/30/1997 MSTA095 Issue plumbing signature form 02/06/1997 DRA PASS RB 02/06/1997 RECD SIGN FORM 2 -5 -97 MSTA097 Issue electric signature form 02/10/1997 DRA PASS KAS 02/10/1997 Recd sign form back 2- 10 -97. MSTA726 Shear Wall lnsp 03/19/1997 GS APP GES 03/19/1997 corrections on jobsite card left by ks are appr MSTA726 Shear Wall Insp 03/18/1997 KS DIS KBS 03/31/1997 #-1- HTT holdowns missed at garage wing walls, nail panel at 3/12 o/c #-2- nail panel #-4- 6/12 o/c #-3- mst straps missed at rear of structure #-4- nail generic panels at 6/12 o/c MSTA735 Gas Line Insp 04/04/1997 KS DIS KBS 04/07/1997 #-1- pressure not adequate for test MSTA725 Framing Insp 04/04/1997 KS DIS KBS 04/07/1997 #-5- support thermostat wire top of fireplace #-6- insulate entire heat ducts at garage MSTA720 Mechanical lnsp 04/07/1997 KS APP KBS 04/08/1997 MSTA725 Framing lnsp 04/07/1997 KS APP KBS 04/08/1997 MSTA735 Gas Line Insp 04/08/1997 KS DIS KBS 04/10/1997 #-1- won't hold pressure MSTA735 Gas Line Insp 04/09/1997 KS DIS KBS 04/10/1997 #-1- won't hold pressure MSTA735 Gas Line Insp 04/14/1997 KS APP KBS 04/15/1997 #-1- gas piping pt test= 30 psi for twenty minutes Page 3 of 4 05/30/2000 Activities for Case #: MST96 -00556 11:46:53 AM EXPIRED Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA799 Building Final 06/12/1997 RB FAIL J *H 09/16/1997 Bldg. final held over until decision regarding stepping determined. Jim Funk and Bob Poskin have determined that the State of Oregon will need to provide and alternate interpretation to allow stepping as built at the present time. See file, interpretation did not result in allowance of the alternate stepping as built. Stepping needs to be corrected. MSTA799 Building Final VLN NOTE VLN 03/10/1999 Inspection request for research to George S. 3110/99. MSTA945 Request inspection research 03/27/2000 JMT DONE No Hold JMT 03/27/2000 SECOND REQUEST MSTA153 Expired by limitation 04/18/2000 HAP DONE No Hold AKJ 04/26/2000 card sent to contractor • Page 4 of 4