Loading...
Permit CITY OF TIGARD i � „ ,, DEVELOPMENT SERVICES MASTER PERMIT - �llid6'li� PERMIT #.. , • ...: MST97 - -004t J . 13125 SW Hall Blvd., Tigard, OR 97223 503 639 -4171 DATE ISSUED: 04 / 4 / 7 PARCEL: 2S103BD -HG034 SITE ADDRESS— : 1254- SW 115TH AVE SUBD I•V LS I ON HUNTER' S ' GLEN ZONING: R -4. 5 PD BLOCK. < — o...: LOT „ ............:034 Remarks: Path 1 — ------------ - ----- ------------------ BUILDING ------------- - - - - -- -------- - - - - -- REISSUE: STORIES : 2 FLOOR AREAS --- - -- -"BASEMENT...: 0 sf REQUIRED SETBACKS - - -- REQUIRED ----- - -- •CLASS OF WORK., :NEW. HEIGHT,,,......,: 18 .FIRST....:' 1192 'if GARAGE,-..;.: 657 sf LEFT:..........: 5 SMOKE DETECTRS: Y TYPE OF USE...:SF FLOOR LOAD : 40 SECOND...: 819 sf FRONT.........: 20 PARKING SPACES: 1 TYPE OF CONST.:5NW_ DWELLING, UNITS :, 1 - . , FINBSMENT: 0..sf RIGHT.... ..... ,• :. 5 OCCUPANCY GRP.:R3 BDRM: 3 BATH: 3 TOTAL - - - - -: 2011 sf VALUE..$: 146152 REAR..........: 26 ------ - - - - -- --- - ----- — PLUMBING. -- . - ---- -- -- - -- ------ ______ SINKS....,,...: 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: '"0 TRAPS • 0 LAVATORIES •4 DISHWASHERS....:. 1. ,FLOOR DRAINS.. :,,. 0, „_ SEWER LINE. ft:,: 0 SF RAIN DRAINS: 1. CATCH BASINS..: 0 TUB /SHOWERS...: 3 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 100 BCKFLW PREVNTR: 1 GREASE TRAPS..: 0 - OTHER FIXTURES: 0 ----- _- - - - - -- ------------ - - - - -- MECHANICAL . FUEL ,TYPES - —=- - -' FURN.�-(,;100K, ..,,,p!'- 0..- _ BOIL /CMP 3HP:.. 0:,.. :VENT , FANS , °..'4...., . CLOTHES.,DRYERS: i /GAS/ / / FURN ) =100K ..: 1 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1 ' MAX INP,..:, .I 0 BTU_ FLOOR FURNACES :, ,0 VENTS • 0... WOODSTOVES „ • ,0,• GAS OUTLETS.:,,:, .1.'',., , . ----- --- - -- -- - -- ---- - - - - -- _, - -. -- RESIDENTIAL UNIT,--,-----SERVICE/FEEDER-7 — TEMP' SRVC /FEEDERS -- . ---BRANCH ,CIRCUITS -- - -- MISCELLANEOUS - -- - -ADD' L INSPECTIONS- - 1000 SF OR LESS: 1 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 4 201 400 •amp,_. p 0 201,:.7 4m amp.:: 0 - 1st W/O SVC /FDR: 0 SIGN/OUT. LIN LT: 0 , PER HOUR • 0 LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL..•: 0 IN PLANT • 0 MANE HM /SVC /FDR: 0 601- 1000 amp. :.0 , 601 +amps -1000 v: 0 . . • MINOR LABEL. -10: 0. . 1!,r,0+ amp /volt.: 0 ----------------------------------- PLAN REVIEW SECIION ------------------ Reconnect. only...: 0- )=4 RES UNITS,.;, • , . ; SVC /FDR)= 225.A.:,.. . )..600•V NOMINAL: .. CLS AREA /SPC OCC: -------- ------------- - - - - -- - ELECTRICAL - RESTRICTED ENERGY -------------------------------------------- , A,, SFRESIDENTIAL---- _-------- --- - -- B. COMMERCIAL- ---- _ ---- --- - - - ------ -------- - - - - -- ----- - - -- - -- AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM : INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR - ALARM..: 0TH: • _,; , :.: X. BOILER,..,..,,,,...: - ... HVAC:........,..: . LANDSCAPE /IRRIG•: PROTECTIVE SIGNL: GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICAL OTHR: .. HVAC DATA /TELE COMM,: NURSE CALLS.:,..: - TOTAL.# SYSTEMS: 0 Owner: ---------------- - --- -- Contractor: ----------------- TOTAL FEES:$ 2788.71 LEGEND HOMES LEGEND HOMES CORPORATION 69v SW HAINES ST 7160 SW HAZELFERN RD. SUITE 100.. TIGARD OR 97223 TIGARD OR 97224 ' ' Phone #: 620- 8',. :.,1. y .. Phone #: 620- 8080. Reg #..: 60563 This permit is• issued subject to the regulations contained in the Tigard., Municipal: Code, State of Ore. Specialty. Codes. and all,ather , applicable laws. All work will be done in accordance with approved.plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended. for more than 180 days. - ---- - - ---- - - - - -- -------- REQUIRED INSPECTIONS - -- ------------------------------------------- Erosion Contol - Post /Beam Meehan. . Electrical. Servi , Fireplace Insp Rain drain Insp. Mechanical Final Grading Inspecti Crawl Drain Electrical Rough Gas Line Insp Water Line Insp Plumb Final Footing Insp . PLM /Underfloor •Framing Insp Gas Fireplace.. _ Water. Service In Building Final Foundation Insp Mechanical Insp Shear Wall Insp Insulation Insp Appr /Sdwlk Insp Post /Beam Struct . Plumb Top;Out . • py Voltage ,.. ; Gyp•Board,.-Insp,, . Electrical Final . 7 t ' Per�mittee Signature 7 9, . .,_ �, id /— Issued By �. �' / 4 r Ca • for inspect Ei.,9..,417.x,,.,,, 1 .. . . Plan Check # OC +721e \ :ITY.OF TIGARD Residential Building Permit Application Recd By �7 3115 SW" HALL BLVD. New Construction Additions or Alterations Date Reed 00/35 IGARD, OR 97223 Single Family Detached or Attached Date to P.E. Z f 0 -al 503) 639 -4171 Date to DST 2 -/ - 7 Print or Type • Permit # ►'1 t'1 00 Su)! 11- Called A'" X17 coy Incomplete or illegible applications will not be accepted Name of Subdivision Lot # Name Job HUNTER'S GLEN 34 LEGEND HOMES Architect Mailing Address Address s ite dress 6900 SW Haines St. 125 115th Avenue Name City /State Zip Phone LEGEND HOMES Tigard, OR 97223 620 -8080 Owner Mailing Address Name 6900 SW Haines St. FROELICH City /State Zi Phone Engineer Mailing Address Tigard, OR 97223 620 -8080 6969 SW Hampton St. City /State Zip Phone Name Tigard, OR 97223 624 -7005 General LEGEND HOMES Describe work new QY addition 0 alteration 0 repair 0 Contractor Mailing Address to be done: 6900 S W Haines St. Additional Description of Work: City/State Zip Phone Tigard, OR 9.7223 620 -8080 Oregon Const. Cont. Board Lic.# Exp. Date Attach Copy of 060563 6/ 19 / 9 7 Project Current COT Business Tax or Metro # Ex . Date Valuation $ Ni /s /- 4 Licenses 1/97 Name 6 NEW CONSTRUCTION ONLY: Name Mechanical SUNGLOW INC. Sq.Ft. House J / Sq.Ft.Garage: Sub- Mailing Address O 5 Contractor ; 2428 S E 105th Corner Lot . Yes . No Flag Lot Yes No -, . City/State Zip Phone (check one) )( (check one) A I Portland, OR 97216 253 -7789 Restricted p Audio /Stereo y a,i,)- Burglar Oregon Const. Cont. Board Lic.# Exp. ate Energy - System Alarm Attach Copy of 148131 '' s3 °/97 Installation 104" Garage Door HVAC Current i COT Business i Tax / Metro # Exp. Date Pr Opener Systems Licenses .1226 ��� Name O i o/ 9(y (check all that Other: Plumbing I WOLCOTT PLUMBING apply) Sub- ' .!ailing Address Will the electrical subcontractor wire for all Yes No P O Box 2 0 0 7 restricted energy installations? X Contractor Has the Subdivision Plat recorded? N/A Yes No City/State Zip Phone A • Gresham, OR 97030 667 -9891 Oregon Const. Cont. Board Lic.# Exp. Date Reissue of MST# Solar Compliance Attach Copy of 9 3 10/19/97 (Calculation Attached) Current Plumbing Lic. # Exo. Date I hereby acknowledge that I have read this application, that the Licenses 2 6 - 2 0 8 P B 8/31/97 information given is correct, that I am the owner or authorized agent of COT Business Tax or Metro # Exp. Date the owner, and that plans submitted are in compliance with Oregon 96-4281 12 / 9y State laws. . Name Sig re of 0 er /Age Date �i Electrical GARNER ELECTRIC ' • °�� // Sub- Mailing Address Con t Perso a me P o d a,,p 21785 SW TV Highway ��� l _ Contractor FOR OFFICE USE ONLY: City/State Zip Phone Plat # ' Map/TL #: Aloha, OR 97006 591 -1320 _ z Oregon Const. Cont. Boa d Lic.# Ex . ate - i5`�. 47 0 Lf1 61; Z f 36� - 146632/ Attach Copy of . //6 7 .L/ K/ /�9/97 S etbacks ' J Zone: Solar: � Current Electrical Lic. # Exp. Date ) / Licenses 34-305C /O 197 R-4(.cP COT Business Tax o � > `at 97 Engineering Approval: Planning Approval: TIF: ists\mstapp.doc /O �:! y �� etro # / � -5l1E PI4 actctQ ka- . t-7 Permit # Account Description Amount Amt. Pd. Bal. Due `nsfy7oo4d MST. Permit (BUILD) ,5150, s _ SS. Plumb. Permit (PLUMB) 225, 22S Mech. Permit (MECH) i j / S, t/S ELC /ELR Permit (ELPRMT) 250. w 250 '` i' State Tax (TAX) S,3 . s' 53, Bldg: 2 2 s3_ / Plumb: //, 22: Mech: 2, Z ELC /ELR: / Z. 5--',.:.-- Plan Check MST: (BUPPLN) 3321-L � / ..f-'--- Plumb: (PLMPLN) Mech: (MECPLN) //, L�� /J - - CDC Review (LANDUS) lo, CIX.150 - 20 sw242-004L( Sewer Connection (SWUSA) ,2-, 0 i vv • • Sewer Inspection (SWINSP) 3. � s 3C, Parks Dev Charge (PKSDC) 105D a ' /05'0. Residential TIF (TIF -R) / ' q -„ /ww Mass Transit TIF (TIF -MT) / "' - �I –C In11.� " /' L I a, Water Quality (WQUAL) Water Quantity (WQUANT) /U U. i lot' 6 Erosion Control Permit (ERPRMT) 6 °J 6 Erosion Planck/USA (ERPLAN) o , 4i, Erosion Planck/COT (EROSN) a 2 - 0. - A. „7- Fire Life Safety (FLS) TOTALS: S 031 - 0 . 5, "�I is \dsts\mstapp.doc Rev. 7/96 51� -- 1 _...Q © A (..7 N 0 124 TRACT 'B' 12449 BAM:1 LN Id l- 2453 ,,,,,,„ 5 ,, -' ■ ' ' Q235 454124S5 24°50 .„.... 4-'1 CO ..1: • ' 2519 ei (1) - 2526 e . 0 * 2514 1 2537 (./) 540 . --" 19 ■ * I 4 .. . = 557 ui 1 0 ERROL ST i . ___, ( • -I Crl 0 " 12554 1! iv Z 12 (3 2 1 II\ ,'" '...k 1 . 1257 4n:A i 0 1 g 5 2g83 86 m 562 i 0 CA 7c) ra - m CCI < r , vy C 0 (I) ( Q 3 2615 2 E.-7. 10 609 m 12602 1 N\ t w 262612621 ‘c' 1 co Fri Q2e53 , - Pl• (.0 G 279 2648 264\ i CARMEN ST. C 1 3 27°12 W 2703 (ft, I - - 716 / C 2727 127'20 , . _ ii ii": . .., .- eii_ . U� S j REE 9 W p,L al � - 7 ® 0 ff r J ,-` m G1� m tD [D 9, 4- s rn a o 12440 r R fD e ; r • R' < gl, 1 SW 4 BAM B I L LN 11577 N ID Cu ! r - �I (D Q, 0 ti M rKD 12454 A```` i N x. v . n m w o cn 12455 :. ' 4 - - ----1._l_ r � 12 �.I_ 12453 ` ^' • q :l 12450 - - , P c 1 2511 • 12526 12519.: • • 12514, �'' 12517 V • "'12 ' 1237 ';' !; . _' 12549 rn CP SW ERROL ST . -® 12540 = (' : 12555 � 12557 012 62 . ., - 6 Cn t t _ 12562 rn 12575 p I V N. 12586 12583 z AG5: (`) ,, - 0 C ' g 'ci N �-/ 1280 s * � 12602 2609 '`'C� Frl C!) -1 `� . • 12615 b � C CA .. 12626 o N A ` 1 V C 12639 12622 0 - 126%8 m Z I C 12653 P1 12664 _ 680 N 12 oa co ,_ co 1269 e _. D c., , SW CARMEN ST. 0 -, . 12703` - wm 12719`. 12712 - O 12720 12.727 C (�) 4�. I • t. \! CITY OF TIGARD BUILDING INSPECTION DIVISION . 24 -Hour Inspection Line: 639 -4175 Business Phone: 639 -4171 Date Requested: 0 i 9 7 A.M. P.M. MST: 9 Location: /256- lin `� . 1 BUP: Tenant: Suite: Bldg: MEC: Contractor: Phone: ...5 PLM: Owner: Phone: ELC: ELR: SIT: BUILDING i n't) PLUMBING MECHANIC ELECTRICAL SITE Site •r• r : eam Post/Beam - os r team Cover /Service Sewer /Storm Footing Roof UndFl/Slab Rough -In Ceiling Water Line Slab Framing Top Out Gas Line Rough -In UG Sprinkler Foundation Insulation Sewer Hood/Duct Reconnect Vault Bsmt Damp Drywall Storm Furnace Temp Service MISC. Masonry Ceiling Rain Drain A/C UG Slab Shear /Sheath Fire Spklr /Alm Crawl/Found Dr Heat Pump Low Volt ,Approve Approved (proved Approved Approved Appr /Sdwlk roved Not Approved Not Not Approved Not Approved FIN FINAL FINAL FINAL FINAL 0 w - � ` c. • rL I 1 G. i.e. 5 1--1 . i bk5 EN . r 0 Call for reinspecti 0 Reinspection fee of $ ' required before next inspection 0 Unable to inspect • Inspector: r • Date: ��y /9 Page of • 5/30/00 • Activities for Case #: MST97 -00040 1:54:56 PM Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes . MSTA005 Application received 2/13/97 JD RECD BON 2/14/97 MSTA008 Permit Created 2/14/97 B PASS BON 2/14/97 MSTA010 Check for prcl. restrict. 2/14/97 . B PASS BON 2/14/97 MSTA012 Plans routed to Plans Examiner 2/14/97 B PASS BON 2/14/97 MSTA026 Plans approved by RPE 2/19/97 RT PASS BT2 . 2/19/97 MSTA030 Reviewed plans routed to DSTS 2/19/97 RT PASS BT2 2/19/97 MSTA032 DST Post - Review Completed 2/24/97 B PASS BON 2/24/97 MSTA700 Erosion Control lnsp 844 -8444 BON 2/14/97 MSTA703 Grading Inspection BON 2/14/97 MSTA705 Footing Insp 3/3/97 KS APP KAS 3/3/97 MSTA706 Foundation Insp 3/4/97 KS APP KBS 3/4/97 MSTA710 Post/Beam Structural 3/12/97 KS APP KBS 3/13/97 MSTA711 Post/Beam Mechanical 3/12/97 KS A/N KBS 3/13/97 #-1- support furnace plenum at crawl from beam above MSTA713 Crawl Drain BON 2/14/97 MSTA717 ?LM /Underfloor 3/11/97 MS PASS MRS 3/11/97 MSTA720 Mechanical Insp BON 2/14/97 MSTA722 Plumb Top Out 4/14/97 MS FAIL MRS 4/15/97 no test upstairs MSTA724 Electrical Rough In 4/18/97 TLP FAIL TLP 4/21/97 service panel not properly labeled MSTA725 Framing Insp 4/23/97 KS DIS KBS 4/24/97 #-1- add nailers to support gypsum at mechanical soffits #-2- add stud above double • garage header at plate splice and strap across #-3- truss clips each side of girder truss #-4- additional nailing needed at ledger supporting rafters liv /rm #-5- provide attic access liv /rm #-6- ventilate bay #-7- support fl joist notched for plumbing excessive MSTA726 Shear Wall Insp 4/10/97 KS APP KBS 4/11/97 MSTA735 Gas Line lnsp 4/23/97 KS APP KBS 4/24/97 #-1- gas piping pt tst =23 psi for 15 minutes MSTA740 Insulation lnsp 4/25/97 KS APP JT 7/22/97 UPDATED FOR KEN. INSPECTION SLIP WAS IN FILE BUT NOT ON TIDEMARK. JT MSTA745 Gyp Board Insp 5/2/97 KS APP KBS 5/2/97 MSTA755 Rain drain Insp 3/5/97 MS PASS - MRS 3/6/97 Page 1 of 2 5/30/00 Activities for Case #: MST97 -00040 1:54:56 PM • Assigned Hold Updated Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes MSTA760 Water Line Insp 3/5/97 MS " PASS MRS 3/6/97 MSTA765 Appr /Sdwlk Insp • 5/6/97 PI • PASS RB 5/7/97 OK MSTA790 Electrical Final 6/13/97 BRP FAIL J *H 6/13/97 Flex conduit under island counter is not grounded (Art. 250 -75 NEC) Receptable • outdoor -rear not CFCI . protected (Art. 210- 8(3)NE). Interior of panel needs cleaning - panel cover bent, paint . chipped, door does not operate . smoothly. (Art. 110 -12c) Circuit breaker ID? (Art. 384 -13 NEC) Fire detectors -smoke detector circuit should be identified. Security system circuit needs . ID. MSTA795 Mechanical Final 6/24/97 KS PASS J *H 6/24/97 MSTA797 Plumb Final 6/13/97 MS PASS J *H 6/13/97 Clean out needs to be brought down to grade. MSTA799 Building Final 6/24/97 KS PASS J *H 6/24/97 • MSTA080 (F) Ready to issue 2/24/97 B PASS BON 2/24/97 MSTA092 (F) Issue combination permit 2/24/97 JMH PASS DST 2/24/97 MSTA095 Issue plumbing signature form 3/4/97 JMH RECD JT 7/28/97 MSTA097 Issue electric signature form 3/10/97 JMH RECD JT 7/28/97 . MSTA722 Plumb Top Out 4/16/97 MS PASS MRS 4/16/97 MSTA723 Electrical Service 4/23/97 TLP PASS TLP 4/23/97 MSTA724 Electrical Rough In 4/23/97 TLP PASS TLP 4/23/97 MSTA790 Electrical Final 6/22/97 BRP FAIL J *H 6/22/97 • not Panel schedule acceptable. Mechanical • protection under counter not complete, Romex is exposed. Panel door is damaged, cover is damaged. MSTA790 Electrical Final 6/23/97 BRP PASS J *H 6/23/97 THE FINAL IS APPROVED IF ACCEPTED BY GENERAL CONTRACTOR. MSTA799 Building Final 6/23/97 KS FAIL J *H 6/25/97 1. Provide handrail at exterior . deck also skirt board at throat of tread and riser. CALL FOR REINSP MSTA725 Framing Insp 7/22/97 4/25/97 KS APP JT 7/22/97 UPDATED FOR KEN. INSPECTION SLIP IN FILE BUT NOT ON TIDEMARK. JT MSTA960 (F) Issue Cert. of Occupancy 6/24/97 JT S *W 8/21/97 mailed 8/21/97 Page 2 of 2 ti- Page No. 1 CASE HISTORY FOR CASE NO.: MST97 -0040 LEGEND HOMES 12562 SW 115TH AVE 08/21/97 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By MSTA005 Application received / / / / 02/13/97 RECD JD 02/14/97 BON MSTA008 Permit Created / / / / 02/14/97 PASS B 02/14/97 BON MSTA010 Check for prcl. restrict. / / / / 02/14/97 PASS B 02/14/97 BON MSTA012 Plans routed to Plans Examiner / / / / 02/14/97 PASS B 02/14/97 BON MSTA026 Plans approved by RPE / / / / 02/19/97 PASS RT 02/19/97 BT2 MSTA030 Reviewed plans routed to DSTS / / / / 02/19/97 PASS RT 02/19/97 BT2 MSTA032 DST Post- Review Completed / / / / 02/24/97 PASS B 02/24/97 BON MSTA080 (F) Ready to issue / / / / 02/24/97 PASS B 02/24/97 BON MSTA092 (F) Issue combination permit / / / / 02/24/97 PASS JMH 02/24/97 DST MSTA095 Issue plumbing signature form / / / / 03/04/97 RECD JMH 07/28/97 JT MSTA097 Issue electric signature form / / / / 03/10/97 RECD JMH 07/28/97 JT MSTA700 Erosion Contol / / / / / / 02/14/97 BON MSTA703 Grading Inspection / / / / / / 02/14/97 BON MSTA705 Footing Insp / / / / 03/03/97 APP KS 03/03/97 KAS MSTA706 Foundation Insp / / / / 03/04/97 APP KS 03/04/97 KBS MSTA710 Post /Beam Structural / / / / 03/12/97 APP KS 03/13/97 KBS MSTA711 Post /Beam Mechanical / / / / 03/12/97 # -1- support furnace plenum at crawl A/N KS 03/13/97 KBS from beam above MSTA713 Crawl Drain / / / / / / 02/14/97 BON MSTA717 PLM /Underfloor / / / / 03/11/97 PASS MS 03/11/97 MRS MSTA720 Mechanical Insp / / / / / / 02/14/97 BON MSTA722 Plumb Top Out / / / / 04/14/97 no test upstairs FAIL MS 04/15/97 MRS MSTA722 Plumb Top Out / / / / 04/16/97 PASS MS 04/16/97 MRS MSTA723 Electrical Service / / I / 04/23/97 PASS TLP 04/23/97 TLP MSTA724 Electrical Rough In / / / / 04/18/97 service panel not properly labeled FAIL TLP 04/21/97 TLP MSTA724 Electrical Rough In / / / / 04/23/97 PASS TLP 04/23/97 TLP MSTA725 Framing Insp / / / / 04/23/97 # -1- add nailers to support gypsum at DIS KS 04/24/97 KBS mechanical soffits # -2- add stud above double garage header at plate splice and strap across # -3- truss clips each side of girder truss # - 4- additional nailing needed at ledger supporting rafters liv /rm # -5- provide attic access liv /rm # -6- ventilate bay # -7- support fl joist notched for plumbing excessive MSTA725 Framing Insp 07/22/97 / / 04/25/97 UPDATED FOR KEN. INSPECTION SLIP IN APP KS 07/22/97 JT FILE BUT NOT ON TIDEMARK. JT MSTA726 Shear Wall Insp / / / / 04/10/97 APP KS 04/11/97 KBS • Page No. 2 CASE HISTORY FOR CASE NO.: MST97 -0040 LEGEND HOMES 12562 SW 115TH AVE 08/21/97 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By MSTA735 Gas Line Insp / / / / 04/23/97 #-1- gas piping pt tst =23 psi for 15 APP KS 04/24/97 KBS minutes MSTA740 Insulation Insp / / / / 04/25/97 UPDATED FOR KEN. INSPECTION SLIP WAS IN APP KS 07/22/97 JT FILE BUT NOT ON TIDEMARK. JT MSTA745 Gyp Board Insp / / / / 05/02/97 APP KS 05/02/97 KBS MSTA755 Rain drain Insp / / / / 03/05/97 PASS MS 03/06/97 MRS MSTA760 Water Line Insp / / / / 03/05/97 PASS MS 03/06/97 MRS MSTA765 Appr /Sdwlk Insp / / / / 05/06/97 OK PASS PI 05/07/97 RB MSTA790 Electrical Final / / / / 06/13/97 Flex conduit under island counter is not FAIL BRP 06/13/97 J *H grounded (Art. 250 -75 NEC) Receptable outdoor -rear not CFCI protected (Art. 210- 8(3)NE). Interior of panel needs cleaning - panel cover bent, paint chipped, door does not operate smoothly. (Art. 110 -12c) Circuit breaker ID? (Art. 384 -13 NEC) Fire detectors -smoke detector circuit should be identified. Security system circuit needs ID. MSTA790 Electrical Final / / / / 06/22/97 2nd inspection: FAIL BRP 06/22/97 J *H Panel schedule not legible, half -words not acceptable. Mechanical protection under counter not complete, Romex is exposed. Panel door is damaged, cover is damaged. MSTA790 Electrical Final / / / / 06/23/97 THE FINAL IS APPROVED IF ACCEPTED BY PASS BRP 06/23/97 J *H GENERAL CONTRACTOR. MSTA795 Mechanical Final / / / / 06/24/97 PASS KS 06/24/97 J *H MSTA797 Plumb Final / / / / 06/13/97 Clean out needs to be brought down to PASS MS 06/13/97 J *H grade. MSTA799 Building Final / / / / 06/24/97 PASS KS 06/24/97 J *H MSTA799 Building Final / / / / 06/23/97 1. Provide handrail at exterior deck FAIL KS 06/25/97 J *H also skirt board at throat of tread and riser. CALL FOR REINSP MSTA960 (F) Issue Cert. of Occupancy / / / / 06/24/97 mailed 8/21/97 JT 08/21/97 S *W