Permit Ah: CITY OF T I G A R D MASTER PERMIT
PERMIT #: MST1999 -00390
'.jli; DEVELOPMENT SERVICES DATE ISSUED: 12/13/99
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171
SITE ADD S: S 12393 SW 114TH TERR ORI l I N A R-4.5 PARCEL: 6 -06400
SUBDIVISION:
"J �v ZONING: R -4.5
BLOCK: LOT: 022 JURISDICTION: TIG
REMARKS: PATH I: New single family dwelling w /attached garage.
BUILDING
REISSUE: STORIES: 2 FLOOR AREAS REQUIRED SETBACKS REQUIRED
CLASS OF WORK: NEW HEIGHT: 22 FIRST: 1,060 sf BASEMENT: sf LEFT: 47 SMOKE DETECTORS: Y
TYPE OF USE: SF FLOOR LOAD: 40 SECOND: 1,035 sf GARAGE: 440 sf FRONT: 20 PARKING SPACES : 2
TYPE OF CONST: 5N DWELLING UNITS: 1 FINBSMENT: sf RIGHT: 5
VALUE: $ 156,901.35
OCCUPANCY GRP: R3 BDRM: 4 BATH: 3 TOTAL; sf REAR: 21
PLUMBING
SINKS: 1 WATER CLOSETS: 3 WASHING MACH: 1 LAUNDRY TRAYS: RAIN DRAIN: 100 TRAPS:
LAVATORIES: 4 DISHWASHERS: 1 FLOOR DRAINS: SEWER LINES: 100 SF RAIN DRAINS: 1 CATCH BASINS:
TUB /SHOWERS: 3 GARBAGE DISP: 1 WATER HEATERS: 1 WATER LINES: 100 BCKFLW PREVNTR: 1 GREASE TRAPS:
OTHER FIXTURES:
MECHANICAL
FUEL TYPES FURN < 100K: BOIL/CMP < 3HP: VENT FANS: 5 CLOTHES. DRYER: 1
GAS FURN > =100K: 1 UNIT HEATERS: HOODS: 1 OTHER UNITS: 1
MAX INP: btu FLOOR FURNANCES: VENTS: WOODSTOVES: GAS OUTLETS: 1
ELECTRICAL
RESIDENTIAL UNIT SERVICE FEEDER TEMP SRVC /FEEDERS BRANCH CIRCUITS MISCELLANEOUS ADD'L INSPECTIONS
1000 SF OR LESS: 1 0 - 200 amp: 0 - 200 amp: W /SVC OR FDR: 1 PUMP /IRRIGATION: PER INSPECTION:
EA ADD'L 500SF: 3 201 - 400 amp: 201 - 400 amp: 1st W/O SVC /FDR: 00 SIGN /OUT LIN LT: PER HOUR:
LIMITED ENERGY: 401 - 600 amp: 401 - 600 amp: EA ADDL BR CIR: SIGNAL/PANEL: IN PLANT:
MANU HM /SVC /FDR: 601 - 1000 amp: 601 +amps- 1000v: MINOR LABEL:
1000+ amp /volt :
PLAN REVIEW SECTION
Reconnect only:
> =4 RES UNITS: SVC /FDR> =225 A.: > 600 V NOMINAL: CLS AREA/SPC OCC:
ELECTRICAL - RESTRICTED ENERGY
A. SF RESIDENTIAL B. COMMERCIAL
AUDIO & STEREO: VACUUM SYSTEM: AUDIO & STEREO: FIRE ALARM: INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM: OTH: BOILER: HVAC: LANDSCAPE/IRRIG: PROTECTIVE SIGNL:
GARAGE OPENER: CLOCK: INSTRUMENTATION: MEDICAL: OTHR:
HVAC: DATA/TELE COMM: NURSE CALLS: TOTAL # SYSTEMS:
Owner: Contractor: TOTAL FEES: $ 4,345.18
• This permit is subject to the regulations contained in the
RIVERSIDE HOMES RIVERSIDE HOMES
Ti
15455 NW GREENBRIER PKWY #140 15455 NW GREENBRIER PKWY all ble law Code, State s. All work will b b done Specialty
BEAVERTON, OR 97006 SUITE 140 all l other Municipal
appllica w and
in
B ITE 14 ON, OR 97006-2115 accordance with approved plans. This permit will expire if
work is not started within 180 days of issuance, or if the
work is suspended for more than 180 days. ATTENTION:
Phone: Phone: Oregon law requires you to follow rules adopted by the
Oregon Utility Notification Center. Those rules are set
Reg #: LIC 70065 forth in OAR 952 - 001 -0010 through 952 -001 -0080. You
may obtain copies of these rules or direct questions to
OUNC by calling (503) 246 -1987.
REQUIRED INSPECTIONS
Erosion 844 -8444 Under insulation Plumb Top Out Gas Line Insp Appr /Sdwlk Insp Building Final
Footing lnsp Crawl Drain /Backwater Electrical Service Gas Fireplace Electrical Final
Foundation lnsp Footing /Foundation Dr Electrical Rough In Insulation lnsp Mechanical Final
Post/Bea.- ructural X 14 M /Underfloor Framing Insp Rain drain Insp Plumb Final
Post/: -am Mechanical Mec nical lnsp Shear Wall Insp Water Line Insp Final inspection
Issu d B : :�a //1J �� /-// /l Permittee Signatu : fi �/ ti
y
Call (503) 639— 175 by 7:00 p.m. for an inspection needed the next business day
t,'TY Of TIGARD Residential Building Permit Application Plan Check# / / - mod
1 3125 SW HALL BLVD. New Construction Re d By d //- bZ
TIGARD, OR 97223 Single Family Detached Date to P.E. /t' 0- 7'
V 503 - 639 -4171 (Ne<r Date to DST 1/ -IS -79
F 503 - 684 -7297 Permit Of 'TM f-06.396
Print or Type Called //-073 -cr
l Incomplete or illegible applications will not be accepted 9 k�
° w �L'Di' " ® �
(_Ql tl , PP- sw21 999 - Comae
Name of Project Name
Job LCa lf_tfl (r '(,1'
_ Architect Mailing Address
Address Site Address
2 c (1
12 ` ,� ` it 1 I -I i rrocQ-- City /State Zip Phone
Name -) ,
h1 ucr:oh Idc
Owner Mailing Address Name
1 f j fn fit: (yr"ccnbr(er k(.(39 Tl 1 yb
Engineer Mailing Address
City /State Zip /n� (�,�,, Phone /, _ p/,, g
t) c\'lie r 177 ()A 7 a?W 6? `7 ) - C98 G City /State Zip Phone
General Name
C:', Contractor ` (,t1 LQ �\, C'(,u f" iil Describe work New 0 Addition 0 Alteration 0 Repair 0
Mailing Address to be done:
Prior to permit Additional Description of Work:
issuance, a copy City /State Zip Phone
of all licenses
are required if Oregon Const. Cont. Board Exp. Date PROJECT ,� g(j /,� t. expired in COT Lic.# c I " . iL r_ ) / -- AV VALUATION
database �J 1 T
Mechanical Name NEW CONSTRUCTION ONLY:
Sub- S q. Ft. House: Sa. Ft. garage � / ,/ Contractor ' +� l.r[D —T / „/_' I ndicate "the restricted energy Y
installation b the e lec t cal v
Prior to permit _ _,
issuance, a copy `� subcontractor in the following areas
of all licenses � or-a ( pg.- 22 T 775 Restricted Audio /Stereo
are required if - °...,.,� I Fyn. Uate Energy System Alarms
expired in COT
Installations Vacuum Irrigation
database 4 + .,3 _ 7/9/c0 System System
Plumbing Name (check all that Other:
Sub - ����5�i Pro) i'CE �
I If; l�1 apply) _
Contractor Mailing Address Number of Units in Building Unit Number Designation
ici,36 Sti) I ()I tll __0'f Has the Subdivision Plat recorded? N/A YES NO
Prior to permit City /State Zip Phone
issuance, a copy p y 4. , ' C < ,1 , t- - 7 -
of all licenses are Ore.. Const. Cont. Board Exp. Date
required if Lic.# 9 1 0 V 1
expired in COT l 330 �
database Plumbing Lic. # Exp. Date I hearby acknowledge that I have read this application, that the
information given is correct, that I am the owner or authorized agent
of the owner, and that plans submitted are in compliance with
Name Oregon State laws.
Electrical /Joie I kcir iC Sign ...01 e of Owner /Agent J' Date
Sub- Mailing Address '.Pi7d ( M
Contractor ( 3 .-- 7s SE "7l I th ' Contact 'erson Na / �y1�(�� Phone #
r(2rJ �� r "" ' ` � _'6RSto
City /State Zip Phone
Prior to permit / �y v
issuance, a copy 1 1/, 311 K 1 d3 j IP66`V 1.4. FOR OFFICE USE ONLY:
of all licenses are Oregon Const. Cont. Board Exp. Date Plat #: Ma /TL : •
#
r fin if Lic. / t3� , A o � / F P 5 - 44
expired in COT WO �/l� �/ I �� � o 3 �� eciR
database Electrical Lic. # �� Exp. Date Se Z R
.C
Electrical Supervisor Lic. # Exp. Date Engirpe�� Approval: Planning pproval: TIF:
//
is \dsts \forms\sfd - new.doc 11/20/98
CITY OF TIGARD BUILDING INSPECTION DIVISION MST M99
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested q Q0 AM PM BLD
Location 2 q 3 1/ T !:/T 1 Suite MEC
Contact Person 19,0 Ph "l y ? , .5 y, q ' / PLM
Contractor Ph SWR
UILDI Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing SEE A �rr !-L i o A272
Insulation
Drywall Nailing A — A* < i , r . * 2
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Mis :
.ASS PART
- �..
PL I BING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final's
PAS T FAIL
CHANICA
Post & Beam
Rough In
Gas Line
Smoke Dampers
PART (
RICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final .�
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk)
Other Date 7- ,C7 Inspector C Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
4 - 05 - 2000 11 :55AM FROM FIRESIDE DIST 15036205699 P. 1
+� w 4vvov_ e. tvx i r v: Mle.A4 1 1 L. I L< 1 9j8bbeVAI P. 1
ea ff kbr
The first na furplaces
p
HEATILATOR, A DIvssaon of Hearth Technologies Ino., 1915 W. Saunders Stract, Mt, Pleasant, Iowa, 52641
'Telephone .319/385 -9211 - FAX 800.259 -1549
Fireside Distributors of Oregon April 5. 2000
16389 SW Boons Petry Rd
Portland. OR 97224
Fun 503.620 -5699
RE: Caliber B•Vent Desiguets/ Mantle Heights
Mitch,
This tatter :s tv cosrfitn the lrtaette height for the Caliber Designer 8- Vents. The correct mantic height is 4r from the
base of the unit. for all mantic projections 0 -12 "- 'the origatal Installation Instruction* had the incorrect mantle height
at 46" on the drawing, but had the correct a2" mantle height in the paragraph above the drawing.
The current installation Instructions reflect the correct 42" mantle height on the drawing.
hole 014 has cleared up any confusion. Please call if you need any further help
Regards,
Bet eras
Heats ator Technical Services
CITY OF TIGARD BUILDING INSPECTION DIVISION )%9 QQ 3 , 0
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
�/ BUP
Date Requested 'J' 2 -7/4064 AM PM BLD
Location 2 .5 i 1 et Suite MEC
n
Contact Person Y Al t 1, Ph 44'3 - PLM
Contractor Ph SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Final
PASS P RT FAIL
UM IN)
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
cFi
AO PART FAIL
"MECHANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA �j /
Approach /Sidewalk Date .J 2 ?! (i Inspector / 7 � 7 Ext
Other
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION j gq1 9-00 ?q
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
`/ BUP
Date Requested 3/ Z 00 AM PM 1c BLD
Location 231 3 1 ) t ` . Suite MEC
Contact Person WifidWiar Ph T7(D 2t2c PLM
Contractor Ph SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Fire wall
Fire Sprinkler /l
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Final
PASS PART FAIL
PLUMBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
MECHANICAL
Post & Beam
Rough In
Gas Line -
Smoke Dampers
Final
PASS PART FAIL
EECTifIC
Service
Rough In
UG /Slab _
Low Voltage
Fire • rm
PART FAIL
ackfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk
Other Date Inspector Ext
Final
PASS PART FAIL DO OT REMOVE this inspection record from the job site.
4/26/00 Activities for Case #: MST1999 -00390
2:11:01 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA005 Application received 11/12/99 GEO RECD No Hold GEO 11/17/99
MSTA008 Permit Created 11/17/99 GEO DONE No Hold GEO 11/17/99
MSTA010 Check for prcl. restrict. 11(17199 GEO DONE No Hold GEO 11/17/99 There is a 15' easment along
the rear of the property, and an
eight foot (8') PUE along the
frontage of both 114th Place
and Walnut Glen.
MSTA012 Plans routed to Plans Examiner 11/17/99 GEO SENT No Hold GEO 11/17/99
MSTA026 Plans approved by Pln Examiner 11/18/99 BT2 DONE No Hold BT2 11118/99
MSTA030 Reviewed plans routed to DSTS 11/18/99 BT2 DONE No Hold BT2 11/18/99
MSTA700 Erosion 844 -8444 11/18/99 11/18/99 No Hold BT2 11/18/99
MSTA705 Footing lnsp 11/18/99 11/18/99 12/21/99 KBS PASS No Hold KBS 12/21/99 #-1- see foundation notes
MSTA706 Foundation lnsp 11/18/99 11/18/99 12/21/99 KBS PASS No Hold KBS 12/21/99 #-1- initial erosion control app
#2 -2- install anchoor bolts size
& spacing as shown
#-3- ufer rod tag
MSTA710 Post/Beam Structural 11/18/99 11/18/99 1/6/00 KS PASS No Hold AKJ 1/6/00
MSTA711 Post/Beam Mechanical 11/18/99 11/18/99 1/6/00 KS PASS No Hold AKJ 1/6/00 1) underfloor pim app
2) supp furnace plenum at crawl
space with metal straps to adj
framing members
3) contractor will install
additional crawl drain at front of
struc
MSTA713 Crawl Drain /Backwater valve 11/18/99 11/18/99 12/22/99 MS PASS No Hold RB 12/22/99
MSTA717 PLM /Underfloor 11/18/99 11/18/99 1/6/00 MRS PASS No Hold MRS 1/6/00
MSTA720 Mechanical Insp 11/18/99 11/18/99 2/9/00 KS FAIL No Hold AKJ 2/9/00 1) no pressure on gas piping
2) provide clearance at fireplace
3) firestop above both fireplaces
4) complete venting at fireplace
5) hard pipe heat duct at gar
wall
6) conn exhaust vents
7) secure insul shield at attic
MSTA722 Plumb Top Out 11/18/99 11/18/99 2/8/00 MRS PASS No Hold AKJ 2/8/00
MSTA723 Electrical Service 11/18/99 11/18/99 2/11/00 TLP PASS No Hold AKJ 2/13/00
MSTA724 Electrical Rough In 11/18/99 11/18/99 2/11/00 TLP PASS No Hold AKJ 2/13/00
MSTA725 Framing Insp 11/18/99 11/18/99 2/15/00 KS FAIL No Hold AKJ 2/15/00 provide app plans on site
MSTA726 Shear Wall lnsp 11/18/99 11/18/99 2/10/00 KS FAIL No Hold AKJ 2/10/00 incomplete several hd's not
installed
MSTA735 Gas Line lnsp 11/18/99 11/18/99 2/9/00 KS FAIL No Hold AKJ 2/9/00 no pressure
Page 1 of 3
4/26/00 Activities for Case #: MST1999 -00390
2:11:01 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA752 Rain drain lnsp 11/18/99 11/18/99 12/27/99 MRS PASS No Hold AKJ 12/27/99
MSTA760 Water Line Insp 11/18/99 11/18/99 12/27/99 MRS PASS No Hold AKJ 12/27/99
MSTA765 APPr /Sdwlk Insp 11/18/99 11/18/99 3/7/00 MW PASS No Hold AKJ 3/7/00
MSTA790 Electrical Final 11/18/99 11/18/99 3/21/00 CD PASS No Hold AKJ 3/21/00
MSTA797 Plumb Final 11/18/99 11/18/99 3/27/00 MRS PASS No Hold AKJ 3/27/00 need to locate house dean out
MSTA799 Building Final 11/18/99 11/18/99 3/27/00 KBS FAIL No Hold AKJ 3/27/00 1) final erosion control app
2) need final plm app
3) post st address
4) seal void at furnace plenum
at stem wall and spot nails
5) seal all pen. at gar also supp
b vent at horiz and adjust collar
6) provide install manual for
fireplace
7) provide access at crawl space
8) need area well at range
exhaust duct at ext
MSTA032 DST Post - Review Completed 11/23/99 GEO DONE No Hold GEO 11/23/99
MSTA080 (F) Ready to issue 11/23/99 GEO DONE No Hold GEO 11/23/99 Need TIF Voucher prior to
issuance.
MSTA092 (F) Issue combination permit 12/13/99 DEB DONE No Hold DEB 12/13/99
MSTA095 Issue plumbing signature form 12/16/99 SLT RECD No Hold ST 12/16/99
MSTA097 Issue electric signature form 12/16/99 SLT RECD No Hold ST 12/16/99
MSTA720 Mechanical Insp 2/13/00 2/13/00 2/11/00 MRS FAIL No Hold AKJ 2/13/00 not enough pressure on gas 10
lbs 15 min
MSTA735 Gas Line Insp 2/13/00 2/13/00 2/11/00 MRS FAIL No Hold AKJ 2/13/00 see mech insp 2/11
MSTA780 «REINSPECTION» 2/13/00 2/13/00 2 /11/00 MRS PAID No Hold GEO 2/14/00 failed gasline 2/11 $50.00
Paid re- inspection fee on
2/14/00, receipt #00- 321691.
MSTA050 Hold for 2/13/00 AKJ DONE No Hold AKJ 2/13/00 reinspect fee due 2/11
MSTA055 Hold Release to Issued 2/14/00 GEO PAID No Hold GEO 2/14/00 re- inspection fee paid on
2/14/00, receipt #00-321691,
$50.00. Replease hold.
MSTA726 Shear Wall lnsp 2/15/00 2/15/00 2 /15/00 KS FAIL No Hold AKJ 2/15/00 provide app plans on site
MSTA720 Mechanical Insp 2/15/00 2/15/00 2 /15/00 KS FAIL No Hold AKJ 2/15/00 provide app plans on site
MSTA735 Gas Line Insp 2/15/00 2/15/00 2/15/00 KS PASS No Hold AKJ 2/15/00
Page 2 of 3
4/26/00 Activities for Case #: MST1999 -00390
2:11:01 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA725 Framing lnsp 2/16/00 2/16/00 2/16/00 KS FAIL No Hold AKJ 2/16/00 1) provide detail for glulam
carrying partial floor load at gar
. 2) nail ledger supp rafters at
fam room
3) add stud at plate splice mstr
bdrm
4) strap plates at upper bay
5) temp glazing above tub
6) provide clearance at comb
air duct to vent at upper
fireplace
MSTA720 Mechanical Insp 2/16/00 2/16/00 2/16/00 KS FAIL No Hold AKJ 2/16/00 see framing 2/16/00
MSTA720 Mechanical Insp 2/21/00 2/21/00 2/18/00 KS PASS No Hold AKJ 2/21/00
MSTA725 Framing Insp 2/21/00 2/21/00 2/18/00 KS PART No Hold AKJ 2/21/00 1) need temp glazing above tub
2) hd's missed
MSTA726 Shear Wall Insp 2/21/00 2/21/00 2/18/00 KS FAIL No Hold AKJ 2/21/00 see framing 2/18
MSTA725 Framing Insp 2/22/00 2/22/00 2/22/00 KS PART No Hold AKJ 2/22/00 glazing above tub needs to be
temp on back order. Will check
at final, window has been
marked with masking tape
MSTA726 Shear Wall lnsp 2/22/00 2/22/00 2/22/00 KS PART No Hold AKJ 2/22/00 see framing 2/22
MSTA740 Insulation Insp 2/22/00 2/22/00 2/22/00 KS PART No Hold AKJ 2/22/00 see framing 2/22
MSTA095 Issue plumbing signature form 3/22/00 SLT RECD No Hold ST 3/22/00 Change of contractor
MSTA795 Mechanical Final 3/30/00 KBS FAIL No Hold AKJ 3/30/00 locked
MSTA799 Building Final 3/30/00 KBS FAIL No Hold AKJ 3/30/00 locked
MSTA795 Mechanical Final 3/31/00 KBS FAIL No Hold AKJ 4/2/00 see bldg final 3/31
MSTA799 Building Final 3/31/00 KBS FAIL No Hold AKJ 4/2/00 1) provide vertical distance to
mantels
2) remove wood and debris at
crawl
3) suppp sst gas tubing in crawl
MSTA795 Mechanical Final 4/7/00 KBS PASS No Hold AKJ 4/9/00 see att letter re: fireplace
mantel height
MSTA799 Building Final 4/7/00 KBS PASS No Hold AKJ 4/9/00
MSTA960 (F) Issue Cert. of Occupancy 4/7/00 KS DONE No Hold ST 4/26/00 4 /26 /00- mailed to owner /BT /file
Page 3 of 3