SGN2010-00170 CITY OF TIGARD SIGN PERMIT
Permit#: SGN2010-00170
COMMUNITY DEVELOPMENT Date Issued: 10/28/2010
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.639.4171 Parcel: 2S102C1301802
Jurisdiction: Tigard
Name of Business: AutoZone
Business Address: 13407 SW PACIFIC HWY
Applicant/Agent: Paulus, Jaylene
Work Description: Installation of one(1)permanent freestanding sign 4'4 3/8"x 16' 1"
Permanent: Yes Freestanding: Yes Freeway: No
Temporary: Wall: No Electronic: No
Billboard: No Balloon: No
Banner: No A-Board: No
Sign Dimensions: 4'4 3/8"x 16' 1"
Total Sign Area: 70
Wall Area:
Wall Face(Direction):
Sign Height: 15 ft.
Projection From Wall: in.
Illumination: Internal
Materials: Alum.Arlon, Flex faces
Electrical Permit Required: Yes
Building Permit Required: No
Total Permit Fee: $164.00
Conditions:
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and
all other applicable law. All work will be done in accordance with approved plans. A permanent sign must be placed within
90 days from approval date or sign permit shall expire. A temporary sign shall expire 30 days from validity date. A balloon
sign shall expire 10 days from validity date.
Approved By:
iii<PA-.9-A-
Perm Signature: hic....11Z
O
lauf-- Eci71 villo
li q City of Tigard OCT 1 4 2010
Sign Permit Application
Cur),
Trmu I 'lu 1It.x
,ARD
TIGARi at ,, .., `„ ,,
i 4y ;'r:9i iu diiJin
GENERAL INFORMATION
Name of Development/Project
FOR STAFF USE ONLY
Site Pt .. illi —..,.SA � O r 0 �il�
Address/ •,...rV Permit No.:
11 D
Location
Suite/Bldg.# City/State Zip Approved By: / '/O/g,11/0 t f 'l
k(61,4_0:).
��[1i• Date: /aI/`->//!v /o/9 �v
Name ` Receipt#:
Property PM t ,C
� Map/TL#: ,c! C18®f :)
Owner Mailing Address \� Suite Zon __ /�+ing: 2 �
1 `\Q C( .J (e. Allowable Total Area: .1.1: 711 �r)Ljf^/�t CR...
City,
1,'ZZip Phone�
" 1 ViA1 ”i 19%101_aU040\403)6 Electrical Permit Required? XYes 0 No
Tenant or 1 Name
Business NI. Building Permit Required? ❑ Yes 0 No
Name i ba- Rev.7/1/10
is\cwpin\masters\land use applications\sign permit app.doc
Sign ^� ynnnLrb.. ,„2_,L._..
Contractor Mailing Address Suite
City/State Zip Phone REOUIRED SUBMITTAL ELEMENTS
'�`$�1 [•�— _[� � (Note: applications will not be accepted
Ore Const. nt. the.Board License# Exp.Date without the required submittal elements)
(.fl 4/0 / 4 a -/7 0 Completed Application Form
ProposedFreestanding ❑ Freeway 0 2 Copies of Site/Plot Plan,Drawn to Scale
p Permanent
Sign Temporary Roof ❑ Electronic (3 copies,if a building permit is required)
(Check all that ❑ Wall ❑ Other
apply) size requirement: 81/2"x 11",or 11"x 17"
�{ ❑ 2 copies of elevations,drawn to scale
N1 New sign? ❑ Alter to existing sign? (3 copies,if a building permit is required)
Sign Dimensions• ! 3 //x 14 t " size requirement: 81/2 x 11",to 24"x 36"
Total Sign Area(sq.ft.): -7`/1) elf. ❑ $164.00 Fee (Permanent sign,any size)
SiData Total Wall Area(sq.ft.) I - ' CI $52.00 Fee (Temporary sign,any type)
-
(Complete all Direction Wall Faces(circle one):
items in this NOTES:
section) N S E W NE NW SE SW
Height to top of sign(feet): ` 3Fir. • Wall signs do not need to be drawn to scale, but
Projection From Wall(inches): must include dimensions of wall face and sign
Materials:tS tX1 T� placement.
�'Ct>>Q t X • Wall signs do not require site/plot plans.
Will sign have illumination? Yes ❑ No • Freestanding signs over 6 ft. required a building
Type: M Internal U External permit.
Are there any existing freestanding or wall signs at this location,
including wall signs that overlap a tenant space?
❑ Yes xNo
If"yes",a list or diagram of all sign dimensions and square (OVER FOR SIGNATURES)
footage must also be submitted.
City of Tigard I 13125 SW Hall Blvd.,Tigard,OR 97223 I 503-718-2421 I www.tigard-or.gov I Page 1 of 2
I hereby acknowledge that I have read this application,that the information given is correct, that I am
the owner or authorized agent of the owner, and that plans submitted are in compliance with the City
of Tigard.
DA"1'ED this ) day of ()C.:ft:)J)1Lt_- ,20 10
4111, •
S.: e .f Owner/Agent
kN-1ca/v,?e"192a6,, s sD ?-34v • zZ//
Contact Person Name Phone No.
City of Tigard I 13125 SW Hall Blvd.,Tigard,OR 97223 I 503-639-4171 www.tigard-or.gov I Page 2 of 2
_ • RECE1V
__{D
)
OCT 2
`; 20.0
ELECTRICAL CONCR c)
CONDUIT CITY TIGA ,i i
PLAN VIEW E, I 6.-;/,-,pr Nr.-.r_Fp1
OTT. CONCRETE: 2.3 CU. YDS.
i - 16'-1" SIGC
-
I
I
i-,-,. gir D
�n1 Zra
ELECTRICAL
a / .• - (-DISCONNECT
�I I Auto Parts o Acce�s,sories o Advice
i 2
0
0 010 3/4" x 0.365" WALL(10" SCH. 40) ASTM A-252 Gr. 3
/--STEEL PIPE EMBEDDED IN FOUNDATION TO WITHIN 3" OF BOTTOM
In
TO CREATE CONCRETE COVER UNDER POLE.
JUNCTION
BOX--Nri
6" BELOW
GRADE
1 GRADE
a
:ss.rl - I' .
•
PER j \ \f: .• 11 •'1 ?
LOCAL CODE •% i. •.i -
ELECTRICAL .. :I ' I1
/,
CONDUIT ', . 1'•;r
a f II
c.
:
O V • 1 • •t j
0 t.
o O
t '' 03'-0" CONCRETE.. ' r; I� : •. ��cc)r.70,- -.
•
, .tI t7 `•069 PE.
I ,r • I
I / v
3" •
•t � �\'�/: `r'A,t•,SPY :'
[CLEAR
ac
\�i r :�S14: - ,.
} ‘,>,-•V%`% EXPIRES 0144
ELEVATION VIEW SITE: AutoZone
Store No. 3786
13405 South West Pacific Highway
Tigard, Oregon 97223
FOUNDATION QESIGN NOTES: A)05 Oel 10 REL FOR PERMITTING J.HOGAN
1. Concrete shall have a minimum compressive strength of 3000 PSI at 28 days. vI an 1 eexerltat I OWNED
2. Caisson footing designed using a soil bearing force of 100 PSF per foot Lateral. Robert—James & Associates Inc.if this soil condition does not exist, it is the Erector's responsibility to have a new
base designed for the existing soil conditions by a Licensed Structural Engineer. 12255 West 187th Street, Mokena Illinois 60448-9737
phone:708-479-8385 fox:708-479-8395 email: rja370comcast.net
DESIGN WINDLOADi
Based on the Oregon Structural Specialty Code (2006 IBC) 'N'E 1 5'-O" OAH DIRECT BURY SINGLE POLE
using Exposure C and 100 mph winds. PYLON FO 4'-4 3/4" x 16'- 1" ID SIGN
xlhet ff 0.MilNNS .050d is I5MLE DRAWING NUMBER SHEET REV.
RaaD" J.HOGAN TE 05 Ocl 10 1 NONE 1010010 ion 1 A
IN CITY OF TIGARD RECEIPT
13125 SW Hall Blvd.,Tigard OR 97223
• 503.639.4171
TIGARD
Receipt Number: 180169 - 10/28/2010
CASE NO. FEE DESCRIPTION REVENUE ACCOUNT NUMBER PAID
SGN2010-00170 Sign Permit 1003100-43115 $143.00
SGN2010-00170 Sign Permit-LRP 1003100-43117 $21.00
Total: $164.00
PAYMENT METHOD CHECK# CC AUTH.CODE ACCT ID CASHIER ID RECEIPT DATE RECEIPT AMT
Check 28149 KPEERMAN 10/28/2010 $164.00
Payor: MEYER SIGN CO. OF OREGON, INC.
Total Payments: $164.00
Balance Due: $0.00
Page 1 of 1
ca e
D/F PYLON SIGN 4'- 4 3/4" x 16'- 1" x 15' OAH (QTY 1) 3/16"=1' 63965
JONES SIGN AutoZone#3756
Quality Grade Square Footage Face Voltage/Circuit Lighting Amps Mounting Pole Anchoring Footin• 13405 SW Pacific Highway
SHOPDRAWING 2-Commercial 70 Double- Flex 120v/(1)20 amp circ. Internal 3 10 Saddle Direct Embed Caison Tigard, OR
Conceptual Artwork
(- )
1 3/4"x 1 3/4"STEEL ANGLE
17'-1" , / SADDLE MOUNT SYSTEM Date
1 1 I_
AkeSales
iv TOP VIEW DETAIL
W
/Ara
►e _
J
iir. roji
J File Location
1AI It' .d Iit OMKr-1=2-1 ilL'L I'LI (x2)12"INCH EYEBOLTS / _
FOR LIFTING
FLEX FACE VIEW 1-/ Construction Drawing
6" (BLEED) FRONT VIEW VIEW DETAIL SIDE VIEW DETAIL (�Sotka
2'-6"
16'-1"CABINET ; Date
16'-1"CABINET /
1 (x2)1/2"LIFTING EYES 1 (9.29.10
1 3/4"x 1 3/4"STEEL ANGLE 1"x 2"x.125
SADDLE MOUNT SYSTEM ALUMINUM TUBE BLEED PRIME ONLY TOP SECTION
3"RETAINER i�, OF POLE(TYP) Project Manager
BLACK * FRAME SYSTEM
N r ® 1) j
P-z G I File Location
Le i
'a �_/,--/ r"Zane®
�V ^ DISCONNECT SWITCH ON CAB.TYPICAL N:\_ 4l
NATIONAL ACCfSutoZone\Sites\Tigard,OR
f� 7� 4 / 3756\Work Order 63965/63965.pdf
10 rt" 6/2 I —Gl lt•11'IaY^`iJ_L.1.1:--2-141.1�l tL_1•\tlel�r -- t —` e_____.---
` 1 I
—
\ INr RADIUS , INEMENIIESEENNEENIEEMEMEE
/ 7"RADIUS \ '-"' Revision Notes
WHITE ARLON SIGN TEC FLEX FACES Q (16)48"HO FLUORESCENT
SCREEN PRINTED GRAPHICS TUBES FIOUNTED VERTICALLY 0422.10 MW Updated per site
oDAY LIGHT BULBS PAINT BOTTOM BLACK
in
.--1 Ln P-1
TEC SCREW TO
012.75"x 375 WALL FASTEN FLEX MATERIAL
36'-3"OA LENGTH TO SIGN CABINET
v
i0
N E A. 4 x 6"HOLE CUT @ 18"FROM GRADE FOR ELECTRICAL CONNECTION
AGRADE UMINUM COVER FOR TORCHED HOLE PAINTED P-1 This Drawing Last Updated on:
1 . i I
COLOR VIEW iOMI PAGE 1 09.29.10'
314"PVC CONDUIT w/PRIMARY
ELECTRICAL WIRING BELOW Finishes
GRADE PER LOCAL CODE
-Paint
19 MIIII P-1 AKZO NOBEL-SIGN4212
o+
I I P-2 White Primer
03'-0"
-SCREEN PRINT COLORS
/
i 5P-1 PMS 165 C
IIS SP-2 BLACK C100%M100%Y100%K100%
CITY OF TIGARD x2"x.125 MN SP-3 PANTONE 485 C
Approved —[ 3"CLEARANCE FOR WATER EXCLUSION WITALUHMRETAINERINUMTUBE FRAME
Conditionally Approved _ [ 3"ALUMINUM RETAINER
.063 PRE-FINISHED BLACK 7.,,...,Ifielle)
For only the work a d scribed i ALUMINUM
PERMIT NC3, s��a�1v,-vv i� 7 /
See Letter o: Follow .-...—.-.-».-...-.-.•••-C 17 I SHEETED WITH.063 PRE-FINISHED
At C - --"[ I BLACK/WHITE ALUMINUM
Job Ad e 7 SA) P'
by: Date
FLEX ATTACH DETAIL PANTONE 165 C BLACK PANTONE 485 C
cl00%
M100%
NTS Y100%
K100%