Permit MASTER PERMIT
CITY OF T I G A R D
PERMIT #: MST2000 -00129
111, DEVELOPMENT SERVICES DATE ISSUED: 05/16/2000
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171
SITE ADDRESS: 12980 SW 113TH PL PARCEL: 2S103AC -FON09
SUBDIVISION: FONNER WOODS ZONING: R -4.5
BLOCK: LOT: 009 JURISDICTION: TIG
REMARKS: single family path 1
BUILDING
REISSUE: STORIES: 2 FLOOR AREAS REQUIRED SETBACKS REQUIRED
CLASS OF WORK: NEW HEIGHT: 26 FIRST: 1,317 sf BASEMENT: sf LEFT: 5 SMOKE DETECTORS: Y
TYPE OF USE: SF FLOOR LOAD: 40 SECOND: 1,443 sf GARAGE: 573 sf FRONT: 60 PARKING SPACES : 2
TYPE OF CONST: 5N DWELLING UNITS: 1 FINBSMENT: sf RIGHT: 5
VALUE: $ 207,932.52
OCCUPANCY GRP: R3 BDRM: 4 BATH: 3 TOTAL: 2,760.00 sf REAR: 55
PLUMBING
SINKS: 1 WATER CLOSETS: 3 WASHING MACH: 1 LAUNDRY TRAYS: 1 RAIN DRAIN: 100 TRAPS:
LAVATORIES: 4 DISHWASHERS: 1 FLOOR DRAINS: SEWER LINES: 100 SF RAIN DRAINS: 1 CATCH BASINS:
TUB /SHOWERS: 3 GARBAGE DISP: 1 WATER HEATERS: 1 WATER LINES: 100 BCKFLW PREVNTR: 1 GREASE TRAPS:
OTHER FIXTURES:
MECHANICAL
FUEL TYPES FURN < 100K: BOIL/CMP < 3HP: VENT FANS: 4 CLOTHES DRYER: 1
GAS FURN > =100K: 1 UNIT HEATERS: HOODS: 1 OTHER UNITS: 1
MAX INP: btu FLOOR FURNANCES: VENTS: WOODSTOVES: GAS OUTLETS: 1
ELECTRICAL
RESIDENTIAL UNIT SERVICE FEEDER TEMP SRVC /FEEDERS BRANCH CIRCUITS MISCELLANEOUS ADD'L INSPECTIONS
1000 SF OR LESS: 1 0 - 200 amp: 0 • 200 amp: W /SVC OR FDR: 1 PUMP /IRRIGATION: PER INSPECTION:
EA ADD'L 500SF: 5 201 - 400 amp: 201 - 400 amp: 1st W/O SVC /FDR: 00 SIGN /OUT LIN LT: PER HOUR:
LIMITED ENERGY: 401 - 600 amp: 401 • 600 amp: EA ADDL BR CIR: SIGNAL/PANEL: IN PLANT:
MANU HM/SVC /FDR: 601 • 1000 amp: 601 +amps- 1000v: MINOR LABEL:
1000+ amp /volt :
PLAN REVIEW SECTION
Reconnect only:
> =4 RES UNITS: SVC /FDR > =225 A.: > 600 V NOMINAL: CLS AREA/SPC OCC:
ELECTRICAL - RESTRICTED ENERGY
A. SF RESIDENTIAL B. COMMERCIAL
AUDIO & STEREO: VACUUM SYSTEM: X AUDIO & STEREO: FIRE ALARM: INTERCOM/PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM: X OTH: BOILER: HVAC: LANDSCAPE/IRRIG: PROTECTIVE SIGNL:
GARAGE OPENER: CLOCK: INSTRUMENTATION: MEDICAL: OTHR:
HVAC: DATA/TELE COMM: NURSE CALLS: TOTAL # SYSTEMS:
Owner: Contractor: TOTAL FEES: $ 6,106.28
This permit is subject to the regulations contained in the
K & W DEVELOPMENT K & W DEVELOPMENT INC Tigard Municipal Code, State of OR. Specialty Codes and
9155 SW RAMBLER LN 9155 SW RAMBLER LN all other applicable laws. All work will be done in
PORTLAND, OR 97223 PORTLAND, OR 97223 accordance with approved plans. This permit will expire if
work is not started within 180 days of issuance, or if the
work is suspended for more than 180 days. ATTENTION:
Phone: 1 { R I N A L Phone: Oregon law requires you to follow rules adopted by the
U Oregon Utility Notification Center. Those rules are set
Reg #: LIC 77980 forth in OAR 952 - 001 -0010 through 952 - 001 -0080. You
may obtain copies of these rules or direct questions to
OUNC by calling (503) 246 -1987.
REQUIRED INSPECTIONS
Erosion 844 -8444 Underfloor insulation Plumb Top Out Low Voltage Water Line Insp Final inspection
Footing lnsp Crawl Drain /Backwater Electrical Service Gas Line lnsp Appr /Sdwlk Insp Building Final
Foundation Insp Footing /Foundation Dr; Electrical Rough In Gas Fireplace Electrical Final
Post/Beam Structural PLM /Underfloor Framing lnsp Insulation Insp Mechanical Final
Post/Beam Mechanical Mechanical lnsp Shear Wall lnsp Rain drain Insp Plumb Final
Issued By : �1
i � � / Permittee Signature : eli
Call (50 639 -4175 by 7:00 p.m. for an inspection needed the next business day
` Plan Check # 9 -51
Re
CITY OF TIGARD Residential Building Permit Application cd CBy heck S P
13125 SW HALL BLVD. New Construction
Date Re • MY 0 0
cd
TIGARD, OR 97223 Single Family Detached Date to P.E. ,Y ""
V 503 - 639 -4171 Date to DST s -.7 -G a
F 503 - 684 -7297 1-17 Permit# trjsf.2o4',..' -012
Print or Type Called 5 .-- 9- o O
Incomplete or illegible applications will not be accepted � ��, � a y
i6�KG cc A,IP oL y 1
Name of Project Name �'S co � n
Job r 1,060 Qs y Architect Mai ' Address D
Address site Address
/z go -Si-) II3 p/
City /State Zip Phone
Nape ,
U Name
Owner Mailing Address r 1
G/ 1 Phone g 'J ..Si" ..i" n
City/State Zip lw („✓ Engineer Mailing Address
Pokil.11149 CF 7 Z 3 2 `' -?/ G 7 City /State Zip Phone
General Name
Contractor 5- 4 - 0 1 -E - Describe work Ne4 Addition 0 Alteration 0 Repair O
Mailing Address to be done:
Prior to permit Additional Description of Work:
issuance, a copy City /State Zip Phone
of all licenses �0 ? Cl 3
are required if Oregon Const. Cont. Board Exp. /ate to PROJECT
expired in COT Lic.# 7 D t� VALUATION $ '
database / c/
Mechanical Name CONSTRUCTION ONLY: /,3z ilf-,
Sub- - n' ^ . Sq. Ft. Houser / Sq. Ft. Ga .�
Contractor Mailing Address
Prior to permit /2 i S. ' v,- Indicate the restricted energy installation by the electrical
issuance, a copy City /State • Zip Phone O subcontractor in the following areas
of all licenses Oit � /bVf( -u3 Restricted Audio /Stereo
are required if Or on Const. ont. Board Exp. Date Energy System 5( Alarms
expired in COT Lic.# Installations X Vacuum Irrigation
database System System
Plumbing Name (check all that Other:
Sub- 3 hi-7`S pZU(n.k /z) ( apply)
Contractor
Mailing Address a / Number of Units in Building Unit Number Designation
r d a �tO Has the Subdivision Plat recorded? N/A YES NO
Prior to permit City /Stat Zip Phone 'V
issuance, a copy ,� J tr/Z, 4 171yo 7,R6^- 8 yZ'
of all licenses are Oregon Const. Cont. Board Ex pi
required if Lic.#
expired in COT / 4 / ( rF7 3// q
tst
database Plumbing Lic. # Exp. Date I hearby acknowledge that I have read this application, that the
information given is correct, that I am the owner or authorized agent
of the owner, and that plans submitted are in compliance with
Name Oregon State laws.
Electrical le/MN t'; LE'L I (, - Sigpature of Owner /Agent Dat A
Sub- Mailing Address -�'a�- 01 1 7 4 v
Contact Person Name hone #
5 f
Contractor a� 55& .L/ (gyp , tNILL,, r z -9/6)
City/State Zip Phone
Prior to permit � y � i
issuance, a copy aiejur. A. f 70 /j .6 7 7/26 FOR OFFICE USE ONLY:
of all licenses are Oregon Const. Cont. Board Exp. Date Plat #: _ 6 ,
required if Lic.# Fh r �� g Map/TL #:
expired in COT 1,16 - ,� 5/O3 . - Fa JO7
database Electrical Lic. # Exp. Date Setbacks: Z �' n;
AC 1 Electrical Supervisor Lic. # Exp. Date Engineering Approval: Planning A proval: TIF:
is \dsts \forms\sfd - new.doc 11/20/98
CITY OF TIGARD
13125 S.W. HALL BLVD. •
TIGARD, OR 97223
I ' 1 7 1 -; ;TVFD
IMPORTANT PERMIT NOTICE j MAY 1 9 2000
TEAM ELECTRIC CO BY:
9400 SE CLACKAMAS RD
CLACKAMAS, OR 97015
Electrical Signature Form
Permit #: MST2000 -00129
Date Issued: 05/16/2000
Parcel: 2S103AC -FON09
Site Address: 12980 SW 113TH PL
Subdivision: FONNER WOODS
Block: Lot: 009
Jurisdiction: TIG
Zoning: R
Remarks: single family path 1
Your company has been indicated as the electrical contractor for the permit indicated above. In order for the
electrical permit to be valid, the signature of the supervising electrician is required. Please have the
appropriate individual from your company sign below and return this Electrical Signature Form prior to the
start of the work to the address above, ATTN: Building Dept.
No electrical inspections will be authorized until this completed form is received
OWNER: ELECTRICAL CONTRACTOR:
K & W DEVELOPMENT TEAM ELECTRIC CO
9155 SW RAMBLER LN 9400 SE CLACKAMAS RD
PORTLAND, OR 97223 CLACKAMAS, OR 97 015
Phone #: 503 - 245 -9167 Phone #: 557 -7180
Reg #: su +e %L U5
ELE 3 -225C
Re CeeNED
MAV A 1 010 AN INK SIGNATURE IS REQUIRED ON THIS FO r
tsCT R GC
1�pt,AA X ./L/A % . Signature of Sup_ ising Electrician
If you have any questions, please call (503) 639 -4171, ext. # 310
CITY OF TIGARD
13125 S.W. HALL BLVD. REC TVED
TIGARD, OR 97223 MAY 2 2 2000
IMPORTANT PERMIT NOTICE BY:
3 MOUNTAINS PLUMBING
PO BOX 386
SHERWOOD, OR 97140
Plumbing Signature Form
Permit #: MST2000 -00129
Date Issued: 05/16/2000
Parcel: 2S103AC -FON09
Site Address: 12980 SW 113TH PL
Subdivision: FONNER WOODS
Block: Lot: 009
Jurisdiction: TIG
Zoning: R
Remarks: single family path 1
Your company has been indicated as the plumbing contractor for the permit indicated above. In order for the
plumbing permit to be valid, please have the appropriate individual from your company sign below and return
this Plumbing Signature Form prior to the start of the work to the address above, ATTN: Building Dept.
No plumbing inspections will be authorized until this completed form is received
OWNER: PLUMBING CONTRACTOR:
K & W DEVELOPMENT 3 MOUNTAINS PLUMBING
9155 SW RAMBLER LN PO BOX 386
PORTLAND, OR 97223 SHERWOOD, OR 97140
Phone #: 503 - 245 -9167 Phone #: 503 - 925 -1342
Reg #: LIC 141187
PLM 34 -368PB
AN INK SIGNATURE IS REQUIRED ON THIS FORM
Signature of Authorized PlumL er
If you have any questions, please call (503) 639 -4171, ext. # 310
-
CITY OF TIGARD BUILDING INSPECTION DIVISION MST Gam/
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
✓
Date Requested / Z - 3 AM PM BLD
Location / 24 $ w 1/3 Suite MEC
Contact Person Ph 70 Y (G 3 � PLM
Contractor Ph SWR
BUILDIN Tenant/Owner ELC
e aining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
1
PART FAIL
PLUMBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
MECHANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
Fire Supply Line
ADA ,h�
Otheoach /Sidewalk Date l �J ��U (1 Inspector �' ��'� Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
_ I
CITY. OF TIGARD esUILDING INSPECTION DIVISION MST ,��- d6'1 z9
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested / Z - 7 AM PM BLD
Location / Z 9 iO 5/.1/13 6 4/ Suite MEC
Contact Person Ph 5-6 76 V4 PLM
Contractor Ph SWR
BUILDII �- Tenant/Owner ELC
- ' g Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear /J >
Framing A /6: r/� c X14/ -A1 C (— Vc it @
Insulation
Drywall Nailing .S /4'0 ,Z, —' @ D Zv. C_,
Firewall
Fire Sprinkler (fife"
Fire Alarm
Susp'd Ceiling GJr r
Roof \ #S b40-445/e--
Misc:
4 - - •SS PART
PLUMBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
- • FAIL
ECHANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
•
PASS PAR
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk _ C7/ -d Inspector Dat nspector E
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION MST 2-‘4 /&?'
24.Hour Inspection Line: 639 -4175 Business Line: 639 - 4171
BUP
Date Requested //- 4- 5 AM PM BLD
Location / 2 f - / Cz Suite MEC
Contact Person Ph 7V--‘0 $ PLM
Contractor Ph SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Final
PASS PART FAIL
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Fin
AS PART FAIL
ECHANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA }�
Approach /Sidewalk Date ° Inspector ), Ext
Other
Final
PASS PART FAIL 0 NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION 2-e,-24' 2 -f
24 -Hour 4nspeotion Line: 639 -4175 Business Line: 639 -4171
BUP .
Date Requested /1- Z 7 AM PM BLD
Location / 90 5 4///3 Suite MEC
Contact Person Ph 7,0y- 603 PLM
Contractor Ph SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes: / /
Slab C ' P p /`� l s S� /' C6 �� U� SIT
Post & Beam /
Ext Sheath /Shear //‘J l /� r74 et , (/ ;� — (one'
Int Sheath/Shear G e An/e // z
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Final
PASS PART FAIL
PLUMBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
MECHANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
EIECTRICA�
Service
Rough b In
Low b 2
Low Voltage
Fi- lar
0 PART FAIL
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin [ ] Please call for rei pection RE: ,f.-- to inspect - no access
Fire Supply Line
ADA
Approach /Sidewalk
Other D Inspectors xt
Final
PASS PART FAIL ' 0 NOT REMOVE this inspection record from the job site.
•
CITY OF TIGARD BUILDING INSPECTION DIVISION MST 0,0> - Ga/z- �
24- HourInspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested //- Z Z AM PM BLD
Location / 2_9 Suite MEC
Contact Person Ph 72q/ , 0Y PLM
Contractor L�},ivt �'- (c- � -iC Ph SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing �/ /� _
Firewall fJ
Fire Sprinkler Vt//in
Fire Alarm
Susp'd Ceiling
Roof
Misc: _
Final 7, -
PASS PART FAIL C
PLUMBING
Post & Beam
Under Slab 15=1. —
Top Out
Water Service A
Sanitary Sewer
Rain Drains
Final L
PASS PART FAIL �l
MECHANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
(ELECTRIC75.
Service
Rough In
UG /Slab
Low Voltage
,�Fii-- Alarm
• SS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA /
Approach /Sidewalk D // Z�/ � Inspector It y
Other i Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
•
CITY OF TIGARD BUILDING INSPECTION DIVISION MST 2-r/l/G v / Z
24 -Hour Inspection Line: 639 -4175 Business Line: 639-41
BUP
Date Requested lU — / AM PM BLD
Location l Z C ' , V 5 //'3 « Suite MEC
Contact Person Ph 7U PLM
Contractor Ph SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Final
PASS PART FAIL
PLUMBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
MECHANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
S PART FAIL
ITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call fo einspection RE: [ ] Unable to inspect - no access
AD
roach /Sidewal Z 'Zdz0 /J1 i f/.1i2 C &1 t '� l
h er Date Inspector Ext 1
F 441 PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION ,24,(42-00/ay
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
i
BUP
Date Requested AM PM BLD
Location / SW //J 77 Suite MEC
Contact Person Ph 741 - � 6 5 PLM
Contractor Ph SWR
41 BUILDING') Tenant/Owner ELC
e aining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear �)
Framing P1/ /L�i��/sc�,
tl , Iatio
Drywall Nailing Y/SU /.�-c A , afil / c.: /7 'G,Z
Firewall
Fire Sprinkler l %PSCJ 1-.4- 77
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Final
P ASS PART
PLUMBING L
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
- .s :eam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk Date 9 � Inspector Ext
Other
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION MST iwo-co1 Zq
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
/' J BUP
Date Requested c(�/ 00 AM PM BLD
Location l 2-q 0 11 Suite MEC
Contact Person C A/U&1, Ph - 704 tD (S 0 p PLM
Contractor Ph SWR
( BtunCD Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
ost & Beam
hear
Int Sheath /Shear
Framing •
Insulation
Drywall Nailing • '71 : crtr
Firewall
Fire Sprinkler — A - - S a ' ` "' -- '
Fire Alarm
Susp'd Ceiling r ls' a ' ' ', .s1ee*-14.5' ` S <S .TC4 s TCi 4 I-t €S
Roof
Misc: Mt./I-74147— / ,�L�•�rU'
Final
PASS PART FAIL y� VL — C) ' �!aiZli 1 S
PLUMBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
CHAN
s Be
Rough In
Gas Line
Smoke Dampers
Final
PASS . 44211 FAIL
ELECTR
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk Date
Other Cam C' Ins Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION MST ,24944, dp /.'
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested 6 AM PM BLD
Location /,20 g0 4 I 1 1't. Suite MEC
Contact Person ( Ph 704 b) PLM
Contractor Ph SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Final
PASS PART FAIL
:sal' IiirY
.s.-
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Fi
PAS) PART FAIL
MECHANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hail, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach/Sidewalk
Other Date 2- Inspector / 7/34 Ext 3 �
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION MST 1-6M-0012.9
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested S/ IS/ 00 AM PM BLD
Location ) ?--q P o i i, ` S
�� • Suite ��jjZ) 77�� MEC
Contact Person f2Ce Ph ? 3 20 — 2 PLM
Contractor Ph SWR
111__MIS Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
o"unda i n FPS
g Drain SGN
Slab
Crawl Drain Inspection Notes: CAA 1 � ,� ' �)
SIT
Post & Beam Ext Sheath/Shear 1 9/441S I 4 b6 a/L in �� DA
Int Sheath /Shear /�
Framing /.1S GL /1ia/'1 -l0ye— 4,717-c 5 -7� S.J/ -C i,� s
Insulation
Drywall Nailing 4‹ Ss44v..._)
Firewall
Fire Sprinkler dr 2 7Z ' Ivy /--</,,, ,c.,, 14e54./7 5
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Final
ART FAIL
L UMBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
MECHANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
Fire Supply Line
ADA
Approach/Sidewalk S.-------°) p
Other Date S - Inspector Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION MST .? _ff)] 2.
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested PM BLD
Location 1 2- 9g 0 l , � l 72.L/ X'
0 Suite MEC
Contact Person b0 Ph 7 20 PLM
Contractor Ph SWR
I6UIL 311 Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
F.. ea io. FPS
Crawl Drain Inspection Notes:
Claw pom. 2 o0 SGN
` SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing (0" •Ve/r
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc: _
Final
PASS PART4if
PLUMBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
MECHANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk Date � — �� Inspector Ext
Other
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION MST 2-P.00
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 �/
/' BUP
Date Requested S// V O0 AM PM/ BLD
Location 1 2.9 go I 2 L. Suite MEC
Contact Person X010 Ph - 77.0-2, 80 PLM
Contractor Ph SWR
UILDI Tenant/Owner ELC
Retaining Wall ELR
•' ;`,.' Access:
. I rS 77. a FPS
Ftg Drain SGN
Crawl Drain Inspection Notes: r0 �v Slab SIT
Post & Beam
Ext Sheath /Shear /� 1�
Ina Sheath /Shear
C t /V " ( pirer.....4 �V fi - ( e _s
Framing V V��
Insulation
Drywall Nailing ,— •
Firewall ; �$- �'
Fire Sprinkler r/' u v� & ,C ' ' +
Fire Alarm \A/_ n ., k ` ��
Susp'd Ceiling j ` ` � 1 �`
Roof e I ` A (�
Misc:
Final I t
PASS AR FAI �� �� ° AEC.
PLUM I
Post &Beam -
Under alab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
MECHANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
S RT FAIL
IT E
Backfill /Grading
Sanitary Sewer b
Storm Drain U
1I [ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin � \ ' v I Reinspection fee of $
Please call for reinspection RE: Unable to inspect - no access
Fire Supply Line G [ p [ p
ADA _
A • • ac / de � ' a t e �/( 4 /G Inspector " (�` Ext--'
t
Fr' "!_
tilip PART FAIL DO NOT REMOVE this inspection record from the job site.
/
L_
CITY OF TIGARD BUILDING INSPECTION DIVISION sT kv - 66/21
24 -Hour Inspection Line: 639-41 5 Business Line: 639 -4171 o -
� j / BUP
Date Requested 6 AM PM !/ BLD
Location /Z / 5Gi//. 3 Suite Ark C
Contact Person Ph 7G V C6.5 PLM
Contractor Ph SWR
{_ BUILDING ) Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framin
Drywall Nailing V 1 r 0,0_ 4,Q clAr ,./....s-ta
9 ^
Firewall t
Fire Sprinkler
Fire Alarm
Susp'd Ceiling ex G " _J
Roof �
Misc
4;y-ep ,
Fi
PART FAIL 1 A- � `` ( ,, ,�
' BING S ` �� (.v `�j c�y„),, ..4 4.
• Post & Beam /� / � - `
Under Slab �4��. QA,(4... Lt.- 1.��(,�. S cN
Top Out f -
Water Service Q S
Sanitary Sewer f / w a_ / d
Rain Drains J \ T �i T
F PASS PART FAIL /A (—t (*L (f , wA5 . 1-..—&-- C . VYyA A
- MECHANI • `' v �15 Qt c r- G CL - e -
Seam _1 v
Rough In
Gas Line J�
Smoke Dampers i AA J t �-,�.,,_._p�_
Final ` 1 7
PASS PART AILJ _ h ` �� . • _ ...AI. — "
Service
Rough In `
UG /Slab 1
Low Voltage Pi '
Fire Alarm 1 � . L V Final
PASS PART FAIL
1 SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk Date yli 6 6
Inspector Ext-�
Other
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION MST 2// , - 2b /
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested e_ AM PM BLD
Location / Z 4 cv Suite MEC
Contact Person Ph 7i x/ S' PLM
Contractor Ph SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Final
PASS PART FAIL
LUMBI
ost & Beam
Under Slab
Top Out
Water Service
Sanita Sewer
F ..
PA -PART FAIL
HANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk
Dat 5.= //- o0 Inspector Ext
Other
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 ) MST &22 —O ��zY
BUP
Date Requested ` / AM PM BLD
Location / Z9 ,9D "c4///1 re' Suite MEC
Contact Person Ph (76 G 0 51' PLM
Contractor Ph SWR
Tenant/Owner ELC
- e airing Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing__ 'f� � !i/ c7, 4 m„- Insulatj
>
Drywall Nailing i 191# 0.2 /L
Firewall
Fire Sprinkler t� cA IA $c1
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Fi
T FAIL
PLUMBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS_ PART FAIL
ECHANI
Post & Beam
ough I It.
as ine �'
Smoke Dampers
Final '
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk
Other Date Inspector Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION ,20/1,4r GG 0-1
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested -� AM PM BLD
Location /,-4,a .Y //.3 Suite MEC
Contact Person Ph ?G ei —‘.0) PLM
Contractor Ph SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Final
PASS PART FAIL
cLUMBII40.
Post & Beam
Under Slab
To •
-ter Serv -
Sanitary Se
Rain II rains
Fi•
GP PART FAIL
HANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
Fire Supply Line
ADA r
Approach /Sidewalk
Other Date r'10 " 00 Inspector A m., Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION MST pivd -Cu / 2 - �
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested �I �/ AM PM BLD
Location / 2 ' 8'G S4. 1(3 V Suite MEC
Contact Person Ph 7c2 cG 31( PLM
Contractor Ph SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing __
Insulation
Drywall Nailing �/ L� 2 �.�� _
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Final
PASS PART FAIL
PLUMBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
MECHANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PAS$_,PART FAIL
ELECTRIC ,►
.UGJSIab
Low Voltage
Fire Alarm
Final
gr PART FAIL
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
Fire Supply Line
ADA
Approach/Sidewalk
Other D � l ) Inspector
Other Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION
ST .2.e4A, �a� �l
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 1
-
BUP
Date Requested O'' 3() AM PM BLD
Location /09.9 -5 w (�3 / Suite MEC
Contact Person Ph 7 ( PLM
Contractor Ph SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
(F r - 7 c G -z02./ - / - c= >
Insulation
Drywall Nailing 1 '4i t e se. j�j ?v�C�IOiv Z �vo�
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Final
PART FAIL
UMBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
NEEt1 ANI
Post & Beam
oug
as �iri
Smoke Dampers
Final
PASS PART FAI
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
Fire Supply Line
ADA
Approach/Sidewalk
Other Date Inspector Ext
Other
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION & 400 2.e./ti, _ pe /2
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested 8' / AM // /7 PM BLD
Location ( / 5 , //3 Suite MEC
Contact Person Ph 2 ` GG 5 PLM
Contractor Ph SWR
BUILDINGS Tenant/Owner ELC
airing Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
✓ Crawl Drain Inspection Notes:
Slab SIT
✓ Post & Beam C
Ext Sheath /Shear \
Int Sheath /Shear I . . A. t -
su - I 4 .0 _ 4 1
Drywall Nailing ATWYAIP • ` • - , A
Firewall /j, Q O / 1„} N.
Fire Sprinkler '" r 1 — •
Fire Alarm
Susp'd Ceiling a \ CY Q C , ^ _ n
U ' 1 C�
Roof
A' _lA ✓\ ' o `- 1 vr, 4 S •
Misc:
Final M OM..- - t - ,c-6e s \
PASS PART 40
PLUMBING 4 r
Post & Slab n 1 A- / � % � `
Under Slab l � /) `� GV
Top Out
Water Service of
Sanitary Sewer v '' II
Rain Drains - Kam'
f� lM
Final I/ , I
PASS PART FAIL . i _ Ate _ -i
cHanllc
0
4 1 f Lt Post & Beam � �
/Sir III.
C / Rough I n'� > i
brfcas Line C ` .► AL A. �"r-
Smoke Dampers �1 ■ ■ A • I. - 0 • . •
Final ' .
PASS PART
m
, r Mr , O1 S ��
ELECTRICAL
Service �-�� a _ V_ ■ •
Rough b In U / [ _ a(--65 6�
UG /Slab - /�� e � 1 �� a Sj
Low Voltage
Fire Alarm A. / C
� ,_ n ! ,L- • .., ^ ` '}- /
i
Final I a /�- �/ " ` 'v< PASS PART FAIL d F I
SITE
Backfill /Grading
0 P ‘ 1A/A.;% L (2_r - -\,A ‹\&61A s sue:
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk Date s l I d
Other U Inspector " (./ Ex t q
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION MST -9bV ,041/ Z Cf
24 - Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested f" 3 AM PM BLD
Location / 7 -t /l.3 Suite MEC
Contact Person Ph 7 �&5 ' PLM
Contractor Ph SWR
C13 Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & B m
c Sheath / Shea
'nt Sheath /Shear
Framing 91/7&■<-0 Al /,it,ts G(
Insulation
Drywall Nailing S T17/44. 1 S
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Final
PASS ART FAIL
PLUM
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
MECHANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk
Other Date — Inspector Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION MST 0 2.,cw/i —GU(2y
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested � 7i AM PM BLD
Location /,.Q irti 5 ✓ /13 Suite MEC
Contact Person Ph 264.05 PLM
Contractor Ph SWR
BUILDING ) Tenant/Owner ELC
Ring Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post &
x heath /Shea �-�
Framing 0% /41- (-
Insulation
Drywall Nailing hkigo S o „ /AC & ...—�
Fire wall C
Fire Sprinkler )
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Final
PASS PART FAIL
PLUMBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
'°MECHANIG>
Post & Beam
Rough In
Smoke Dampers
Fin
ASS PART FAIL
TRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspecti +n. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin [ ] Please call for reinspection RE: / [ ] Unable to inspect - no access
Fire Supply Line
ADA
Approach /Sidewalk -"
Date r
Other �" Ins Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION
MST
re _ 9
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested Z- Z 1 AM PM BLD
Location ( Sr72 54,111 C( , Suite MEC
Contact Person - Yd Ph 70i O71 PLM
Contractor Ph SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing _ f� 5 ` s - ar d
Insulation
Drywall Nailing AIL -71 -/_ "" r /Li. AC.
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Final
PASS PART FAIL
PLUMBING
Post & Beam
Under Slab
Top Out
Water Service
Sanitary Sewer
Rain Drains
Final
PASS PART FAIL
MECHANICAL
Post & Beam
Rou h
L.
as Line
�Smo e Dampers
Final '
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk Date 7 7- Inspector Ext
Other
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION
MST ( - ) /491/ Ga�2 y
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
�7 -, / BUP
(
Date Requested -' 24 AM PM BLD
Location /02?/ Sr .Sw 1/ 3 Suite MEC
Contact Person Ph ?D q 4 rie PLM
Contractor Ph SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
Final
PASS PART FAIL
� _UDI181NG
-ost & Beam
Under Slab o e s
Top Out
Water Service
Sanitary Sewer
Rain Drains
F'. .
PAS PART FAIL
MECHANICAL
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk yy�
Other Date Inspector ,%,! ' Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
CITY OF TIGARD BUILDING INSPECTION DIVISION MST -/
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested 2/= - ,d ' AM PM BLD
Location /e % ' 5 // 3 /`-( Suite MEC
Contact Person Ph PLM
Contractor Ph Yo y - o > Y SWR
BUILDING Tenant/Owner ELC
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes: •
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing
Firewall
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof _ 1��/
Misc:
Final /?'/
PASS PART FAIL
,PLUMBING
fast- &-Beam
U b
Water Service
Sanitary Sewer
Rain Drains
gFi l
P 4S PART
ECHANICA
Post & Beam
Rough In
Gas Line
Smoke Dampers
Final
PASS PART FAIL
ELECTRICAL
Service
Rough In
UG /Slab
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin
Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
ADA
Approach /Sidewalk Date 2%S :// Inspector ki Ext„
Other
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.
•
•
MST - Master Permit
I Inspection Description Date Passed By Notes •
Grading
Footing /Setback
Foundation walls
Slab
Footing drain
Waterproof basement walls
Plumbing underslab
Crawl drain
Post/beam plumbing
Post/beam mechanical
Underfloor insulation
Post/beam structural
Shear walls /anchors
Exterior sheathing
Plumbing top -out
Gas line & test
Mechanical rough -in
Electrical rough -in
Electrical service
Low voltage
Sprinkler rough -in
Backflow preventer
Roof nailing
Firewall
Framing
MFG -Home set -up
Insulation
Drywall nailing
Masonry/Reinforcement
Rain drain
Sanitary sewer
Water service
Pump /fill septic tank
Approach /sidewalk
Grading final
Mechanical final
Plumbing final
Electrical final f0S /Final inspection
Special Reports
SWR - Sewer Permit
Inspection Description Date Passed By Notes
Sanitary sewer
Final inspection
INSPECTION RECORD — MST (MASTER) PERMITS
_ _
•• ...
A . CITY OF TIGARD MASTER PERMIT
.f P DEVELOPMENT SERVICES DATES ISSUED: 5/16/00 0 -0
- 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171
SITE ADDRESS: 12980 SW 113TH PL I � PARCEL: 2S103AC -FON09
SUBDIVISION: FONNER WOODS r 1./ ONING: R -4.5
BLOCK: LOT: 009 JURISDICTION: TIG
REMARKS: single family path 1
BUILDING
REISSUE: STORIES: 2 FLOOR AREAS REQUIRED SETBACKS REQUIRED
CLASS OF WORK: NEW HEIGHT: 26 FIRST: 1,317 sf BASEMENT: sf LEFT: 5 SMOKE DETECTORS: Y
TYPE OF USE: SF FLOOR LOAD: 40 SECOND: 1,443 sf GARAGE: 573 sf FRONT: 60 PARKING SPACES : 2
TYPE OF CONST: 5N DWELLING UNITS: 1 FINBSMENT: sf RIGHT: 5
VALUE: $ 207,932.52
OCCUPANCY GRP: R3 BDRM: 4 BATH: 3 TOTAL: 2,760.00 sf REAR: 55
PLUMBING
SINKS: 1 WATER CLOSETS: 3 WASHING MACH: 1 LAUNDRY TRAYS: 1 RAIN DRAIN: 100 TRAPS:
LAVATORIES: 4 DISHWASHERS: 1 FLOOR DRAINS: SEWER LINES: 100 SF RAIN DRAINS: 1 CATCH BASINS:
TUB /SHOWERS: 3 GARBAGE DISP: 1 WATER HEATERS: 1 WATER LINES: 100 BCKFLW PREVNTR: 1 GREASE TRAPS:
OTHER FIXTURES:
MECHANICAL
FUEL TYPES FURN < 100K: BOIL/CMP < 3HP: VENT FANS: 4 CLOTHES DRYER: 1
GAS FURN > =100K: 1 UNIT HEATERS: HOODS: 1 OTHER UNITS: 1
MAX INP: btu FLOOR FURNANCES: VENTS: WOODSTOVES: GAS OUTLETS: 1
ELECTRICAL
RESIDENTIAL UNIT SERVICE FEEDER TEMP SRVC /FEEDERS BRANCH CIRCUITS MISCELLANEOUS ADD'L INSPECTIONS
1000 SF OR LESS: 1 0 - 200 amp: 0 - 200 amp: W /SVC OR FDR: 1 PUMP /IRRIGATION: PER INSPECTION:
EA ADD'L 500SF: 5 201 - 400 amp: 201 - 400 amp: 1st W/O SVC /FDR: 00 SIGN /OUT LIN LT: PER HOUR:
LIMITED ENERGY: 401 - 600 amp: 401 - 600 amp: EA ADDL BR CIR: SIGNAL/PANEL: IN PLANT:
MANU HM /SVC /FDR: 601 - 1000 amp: 601 +amps- 1000v: MINOR LABEL:
1000+ amp /volt :
PLAN REVIEW SECTION
Reconnect only:
> =4 RES UNITS: SVC /FDR> =225 A.: > 600 V NOMINAL: CLS AREA/SPC OCC:
ELECTRICAL - RESTRICTED ENERGY
A. SF RESIDENTIAL B. COMMERCIAL
AUDIO & STEREO: VACUUM SYSTEM: X AUDIO & STEREO: FIRE ALARM: INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM: X OTH: BOILER: HVAC: LANDSCAPE/IRRIG: PROTECTIVE SIGNL: //
GARAGE OPENER: CLOCK: INSTRUMENTATION: MEDICAL: OTHR:
ilhi HVAC: DATA/TELE COMM: NURSE CALLS: TOTAL # SYSTEMS:
Owner: Contractor: TOTAL FEES: $ 6,106.28
t . "%si l
K & W DEVELOPMENT K & W DEVELOPMENT INC This permit is subject to the regulations contained in the
9155 SW RAMBLER LN 9155 SW RAMBLER LN Tigard Municipal Code, State of OR. Specialty Codes and
IN d i
PORTLAND, OR 97223 PORTLAND, OR 97223 all other applicable laws. All work will be done in
accordance with approved plans. This perm it will expire if
work is not started within 180 days of issuance, or if the
work is suspended for more than 180 days. ATTENTION:
%
Phone: Phone: Oregon law requires you to follow rules adopted by the
Oregon Utility Notification Center. Those rules are set
C
Reg #: LIC 77980 forth in OAR 952 - 001 -0010 through 952 - 001 -0080. You
may obtain copies of these rules or direct questions to
OUNC by calling (503) 246 -1987.
REQUIRED INSPECTIONS
Erosion 844 -8444 Post/Beam Mechanica Mechanical Insp Framing lnsp Gas Line Insp Appr /Sdwlk Insp
8
Footing Insp Underfloor insulation Plumb Top Out Shear Wall Insp Gas Fireplace Electrical Final
Foundation lnsp Crawl Drain /Backwate Plumb Top Out Shear Wall Insp Insulation Insp Mechanical Final
Foundation lnsp Footing /Foundation Dr Electrical Service Low Voltage Rain drain lnsp Plumb Final
Post/Beam Structural PLM /Underfloor Electrical Rough In Gas Line Insp Water Line Insp Final inspection `
NI
Issued By : Permittee Signature :
Call (503) 639 -4175 by 7:00 p.m. for an inspection needed the next business day %.440
8/16/00 Activities for Case #: MST2000-001 29
2:32:40 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
:n •
MSTA005 Application received 4/26/00 KSP No Hold BT2 5/3/00
r
MSTA008 Permit Created 5/3/00 BT2 DONE No Hold BT2 5/3/00 r 1
J
MSTA010 Check for prcl. restrict. 5/3/00 BT2 DONE No Hold BT2 5/3/00
MSTA012 Plans routed to Plans Examiner 5/3/00 BT2 DONE No Hold BT2 5/3/00
MSTA026 Plans approved by Pln Examiner 5/3/00 BT2 DONE No Hold BT2 5/3/00
MSTA030 Reviewed plans routed to DSTS 5/3/00 BT2 DONE No Hold BT2 5/3/00
MSTA700 Erosion 844 -8444 No Hold BT2 5/3/00
MSTA705 Footing Insp 5/19/00 RB PART No Hold AKJ 5/21/00 1) muck footing at rear 20 ft of
dwelling
2) extract roots from footing
3) maintain seis req as per PF
and ABC
4) provide an adeq keyway
MSTA706 Foundation Insp 5/24/00 KBS FAIL No Hold AKJ 5/24/00 not ready
MSTA710 Post/Beam Structural No Hold BT2 5/3/00
MSTA711 Post/Beam Mechanical 6/6/00 KBS PART No Hold AKJ 6/6/00 1) strap built up mud sill at front
of structure
2) add post at notched 4x12
beam
3) provide sleeve at sst gas
tubing in contact with plenum
4) remove wood forms
MSTA712 Underfloor insulation No Hold BT2 5/3/00
MSTA713 Crawl Drain /Backwater valve No Hold BT2 5/3/00
MSTA714 Footing /Foundation Drain No Hold BT2 5/3/00
MSTA717 PLM /Underfloor 6/2/00 MRS PASS No Hold AKJ 6/4/00
MSTA720 Mechanical lnsp No Hold BT2 5/3/00
MSTA722 Plumb Top Out 7/26/00 MRS FAIL No Hold MRS 7/26/00 no test upstairs
MSTA723 Electrical Service No Hold BT2 5/3/00
MSTA724 Electrical Rough In No Hold BT2 5/3/00
MSTA725 Framing Insp No Hold BT2 5/3/00
MSTA726 Shear Wall Insp 8/2/00 KBS FAIL No Hold KBS 8/3/00 #-1- provide app plans site
MSTA728 Low Voltage .
No Hold BT2 5/3/00 •
MSTA735 Gas Line Insp 7/27/00 KBS FAIL No Hold KBS 7/27/00 #-1- sleeve sst gas tubing .
penetrating metal flashing @ •
furnace •
MSTA736 Gas Fireplace •
No Hold BT2 5/3/00
+
MSTA740 Insulation lnsp +
No Hold BT2 5/3/00
Page 1 of 2
8/16/00 Activities for Case #: MST2000-001 29
2:32:40 PM
Assigned Hold Updated •
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA752 Rain drain Insp 8/11/00 EH PASS No Hold AMS 8/11/00
MSTA760 Water Line Insp No Hold BT2 5/3/00 _-
,
MSTA765 Appr /Sdwlk Insp No Hold BT2 5/3/00
MSTA790 Electrical Final No Hold BT2 5/3/00
MSTA795 Mechanical Final No Hold BT2 5/3/00
MSTA797 Plumb Final No Hold BT2 5/3/00
MSTA798 Final inspection No Hold BT2 5/3/00
MSTA799 Building Final No Hold BT2 5/3/00
MSTA032 DST Post - Review Completed 5/9/00 GEO DONE No Hold GEO 5/9/00
MSTA080 (F) Ready to issue 5/9/00 GEO DONE No Hold GEO 5/9/00
MSTA092 (F) Issue combination permit 5/16/00 GEO DONE No Hold GEO 5/16/00
MSTA095 Issue plumbing signature form 5/22/00 SLT RECD No Hold ST 5/22/00
MSTA097 Issue electric signature form 5/19/00 SLT RECD No Hold ST 5/19/00
MSTA706 Foundation Insp 5/25/00 KBS PASS No Hold AKJ 5/25/00
MSTA722 Plumb Top Out 7/27/00 MRS PASS No Hold MRS 7/27/00
MSTA735 Gas Line Insp 8/2/00 KBS PASS No Hold KBS 8/3/00 # -1- gas piping pt test- 19 psi
for 15 minutes tag # 380046
MSTA726 Shear Wall Insp 8/3/00 KBS PART No Hold KBS 8/3/00 # -1- tighten nuts @ garage
holdowns also install straps
above
MSTA093 (F) Reprint Permit 8/9/00 ZZZ DONE No Hold ZZZ 8/9/00
MSTA761 Water Service Insp 8/9/00 EH PASS No Hold AMS 8/10/00
MSTA704 Sewer Inspection 8/9/00 EH PASS No Hold AMS 8/10/00
Page 2 of 2