Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
MASTER PERMIT C 1�T OF TIGARD PERMIT #: MST2008 00121 1111 ° COMMUNITY DEVELOPMENT DATE ISSUED: 9/9/2008 TIGARD 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 PARCEL: 2 S 103 D B - 01400 SITE ADDRESS: 13505 SW 110TH AVE ZONING: R - 4.5 SUBDIVISION: MIRA PARK LOT: 010 JURISDICTION: TIG PROJECT: JEBBIA Project Description: Remove and replace deck, from 340 sq ft to 408 sq ft deck. BUILDING REISSUE: STORIES: 1 FLOOR AREAS REQUIRED SETBACKS REQUIRED CLASS OF WORK: OTR HEIGHT: 8 FIRST: 405 sf BASEMENT: sf LEFT. 5 SMOKE DETECTORS: TYPE OF USE: SF FLOOR LOAD: 50 SECOND: sf GARAGE: sf FRONT: 20 PARKING SPACES : TYPE OF CONST: 5N DWELLING UNITS: THIRD: sf RIGHT: 5 VALUE: 7 617.36 OCCUPANCY GRP: R3 BDRM: BATH: TOTAL: 408 sf REAR: 12 PLUMBING SINKS: WATER CLOSETS: WASHING MACH: LAUNDRY TRAYS: RAIN DRAIN: TRAPS: LAVATORIES: DISHWASHERS: FLOOR DRAINS: SEWER LINES: SF RAIN DRAINS: CATCH BASINS: TUB /SHOWERS: GARBAGE DI5P: WATER HEATERS: WATER LINES: BCKFLW PREVNTR: GREASE TRAPS: OTHER FIXTURES: MECHANICAL FUEL TYPES FURN < 100K: BOIL/CMP < 3HP: VENT FANS: CLOTHES DRYER: FURN > =100K: UNIT HEATERS: HOODS: OTHER UNITS: MAX INP: btu FLOOR FURNANCES: VENTS: WOODSTOVES: GAS OUTLETS: ELECTRICAL RESIDENTIAL UNIT SERVICE FEEDER TEMP SRVC /FEEDERS BRANCH CIRCUITS MISCELLANEOUS ADD'L INSPECTIONS 1000 SF OR LESS: 0 - 200 amp: 0 - 200 amp: W /SVC OR FOR: PUMP /IRRIGATION: PER INSPECTION: EA ADD'L 500SF: 201 - 400 amp: 201 - 400 amp: 1st W/O SVC /FDR: SIGN /OUT LIN LT: PER HOUR: LIMITED ENERGY: 401 - 600 amp: 401 - 600 amp: EA ADDL BR CIR: SIGNAL/PANEL: IN PLANT: MANU HM /SVC /FDR: 601 - 1000 amp: 601 +amps- 1000v: MINOR LABEL: 1000+ amp /volt : PLAN REVIEW SECTION Reconnect only: > =4 RES UNITS: SVC /FDR> =225 A.: > 600 V NOMINAL: CLS AREA/SPC OCC: ELECTRICAL - RESTRICTED ENERGY A. SF RESIDENTIAL B. COMMERCIAL AUDIO & STEREO: VACUUM SYSTEM: AUDIO & STEREO: FIRE ALARM: INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM: OTH: BOILER: HVAC: LANDSCAPE/IRRIG: PROTECTIVE SIGNL: GARAGE OPENER: CLOCK: INSTRUMENTATION: MEDICAL: OTHR: HVAC: DATA/TELE COMM: NURSE CALLS: TOTAL # SYSTEMS: This permit is subject to the regulations contained in the Tigard Owner: Contractor: Municipal Code, State of OR. Specialty Codes and all other applicable JOE JEBBIA WALTER BROS CONSTRUCTION LLC laws. All work will be done in accordance with approved plans. This 13505 SW 110TH 11795 SW TUALATIN RD #8 permit will expire if work is not started within 180 days of issuance, or TIGARD, OR 97223 TUALATIN, OR 97062 if the work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through 952 - 001 -0080. You may obtain copies of these rules or direct Phone: 503 - 639 - 1275 Contact #: PRI 503 332 - 5076 questions to OUNC by calling 503.246.6699 or 1.800.332.2344. FAX 503- 855 -3572 Reg #: LIC 178555 TOTAL FEES: $ 277.64 REQUIRED ITEMS AND REPORTS A II At i Issue = � / i N Permittee Signature : ffi r 1 ' Call 503.639.4175 by 7:00 a.m. for an inspection that busin s day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. /3tip5 3 //6 .-1 - 1-- Si= Residential " . - FOR OFFICE USE ONLY' ��q . . City of Tigard "�� EC Date/B y b r r o a �% Permt No.. '5/ 91 13125 SW Hall Blvd., Tigard, Rs Plan Review I 1 W C . ' Phone: 503.639.4171 Fax: 503.598.1960 1 t Date/By. J / '�Q / Or�� j �' F_ Other Permit: TIGARD Inspection Line: 503.639.4175 AUC 1 2 � +"� Date Ready /Bf. l t �y RI See Page 2 for Internet: www.tigard - or.gov Notified/Method:D/ ZIA S Cq Supplemental Information '. '`LL : TYPF AMRI£) • OW t.51- w.. - .. ., ° REQUll ED DATA:.•1'= AND 2- FAMILY DWELLING " El New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all V Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the ' work indicated on this application. . - ` _ CATEGORY .OF' CONST RUCTION •' — . 1- and 2-family dwelling Valuation: $ y g ❑ Commercial /industrial ❑ 4-1= Accessory building ❑ Multi- family Number of bedrooms: / ❑ Master builder ❑ Other: Number of bathrooms: . "JOB SITE INFORMATION AND •.LOCATION, - s Total number of floors: Job site address: j 505 Sy )10 rl G New dwelling area: square feet City /State /ZIP: 1 r#1 0e 9 12� Garage /carport area: square feet Suite/bldg. /apt. no.: // Project name: pet, re yO/Uuo e 4 Covered porch area: square feet Cross street/directions to job site: Deck area: square e feet Other structure area: square feet REQUIRED'DATA: COMMERCIAL- USECIIECKLIST Subdivision: Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the „ ' DSC ERIPTN = IOOF, WOR_ K , - work indicated on this application. 0,6101/e. 10 X3 Gie_GIG 6 id 1 2) 3'/ pe, Valuation: $ Existing building area: square feet New building area: square feet ` PROPERTY OWNER' _ , : - ❑ = TENANT ' Number of stories: Name: j ©E , \ ( b h ; G Type of construction: Address: is cc, S 5 o la Y� 51 Occupancy groups: City /State /ZIP: T; S 6 ,4 Oa ei L 1 f Existing: Phone: ( ) 6 39 - I Z i 5 -- Fax: ( ) New: r APPLICANT ". . ., .. ❑ CO P • yP' °.: -. : , , NOTICE ., '`U Business name: W a t �f 6_0 5 (-„ 5 )- (A , Li...Q All contractors and subcontractors are required to be Contact name: J A � �� licensed with the Oregon Construction Contractors Board W under ORS 701 and may be required to be licensed in the Address: 11115 SW Tula (a t " g-D *6-7 jurisdiction in which work is being performed. If the City/State /ZIP: T I aim 8 ��6a applicant is exempt from licensing, the following reasons 2 apply: Phone: ( 6 337- 5-070 F ax:: (5 3 ) �lSS' 35- 7 2 _ E -mail: P l l - b `) Gp rs rMGRJrx 0 (Ar+nC.G.g t. n2^}' ... ' CONTRACTORS . Business name: / / kr 6 r 5 ex n4'�em tom( ivv. • ' ' • BUILDINGPERMIT , FEES *- .. - • Address: �" se to fee ., ' ('9el..� 5P liAA (G 1-rh D a. to -7 f a„ City /State /ZIP: ' (Plea . l Structural plan review fee (or deposit): 0 � T T�lal4 h� D. lw,62 Phone: ( .5 7 - co') ( Fax: (• ) 8 3 5 07 Z FLS plan review fee (if applicable): CCB lie.: j j g - s Total fees due upon application: e:-//k_, Amount received: Authorized signature: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: J e * f Q ✓ Date: eh ( / ©g * Fee methodology set by Tri -County Building Industry Service Board. I: \Building\Permits \BUP -RES PermitApp.doc 11/6/07 440- 4613T(11/02/COM/WEB) Building Permit Application Checklist One- and Two- Family Dwelling FOR OFFICE USE ONLY City of Tigard Received Permit No a 1 3125 SW Hall Blvd , Tigard, OR 97223 Date/By: :. ; • Phone: 503.639 4171 Fax: 503.598.1960 Associated permits: TIGARD 24- Hour Inspection Line: 503.639.4175 ❑ Electrical ❑ Plumbing ❑Mechanical Internet: www.tigard - or.gov ❑ Other: THE' FOLLOWING ,ITEMS, ARE' REQUIRED ; FOR PLAN REVIEW Yes I No , N/A 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ❑ ❑ 2 Zoning. Flood plain, solar balance points, seismic soils designation, historic district,.etc. . . Cl ❑ ❑ 3 Verification of approved plat /lot. ❑ ❑ ❑ 4 Fire district approval required. Name of district: . ❑ ❑ ❑ 5 Septic system permit or authorization for remodel. Existing system capacity ❑ ❑ ❑ 6 Sewer permit. ❑ ❑ ❑ 7 Water district approval. ❑ ❑ ❑ _ 8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ ❑ ❑ 9 Erosion control ❑ plan ❑ permit required. Include drainage -way protection, silt fence design and location of catch- ❑ ❑ ❑ basin protection, etc. 10 3 Complete sets of legible plans. Must be drawn to scale, showing conformance to applicable local and state ❑ ❑ ❑ building codes. Lateral design details and connections must be incorporated into the plans or on a separate full -size sheet attached to the plans with cross references between plan location and details. P lan review cannot be completed if copyright violations exist. 11 S ite /plot plan drawn to scale. T he plan must show lot and building setback dimensions; property corner elevations (if ❑ ❑ ❑ there is more than a 4 -ft. elevation differential, plan must show contour lines at 2 -ft. intervals); location of easements and driveway; footprint of structure (including decks); location of wells /septic systems; utility locations; direction indicator; lot area; building coverage area; percentage of coverage; impervious area; existing structures on site; and surface drainage. 12 Foundation plan. Show dimensions, anchor bolts, any hold -downs and reinforcing pads, connection details, vent size Cl ❑ ❑ and location. 13 Floor plans. Show all dimensions, room identification, window size, location of smoke detectors, water heater, ❑ ❑ ❑ furnace, ventilation fans, plumbing fixtures, balconies and decks 30 inches above grade, etc. 14 Cross section(s) and details. Show all framing- member sizes and spacing such as floor beams, headers, joists, sub- ❑ ❑ ❑ floor, wall construction, roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing, roofing, roof slope, ceiling height, siding material, footings and foundation, stairs, fireplace construction, thermal insulation, etc. 15 Elevation views. Provide elevations for new construction; minimum of two elevations for additions and remodels. ❑ ❑ ❑ Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full -size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing (prescriptive path) and /or lateral analysis plans. Must indicate details and locations; for non- ❑ ❑ ❑ prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor /roof framing. Provide plans for all floors /roof assemblies, indicating member sizing, spacing, and bearing ❑ ❑ ❑ locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ ❑ ❑ systems, see item 22, "Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ ❑ over 10 feet long and /or any beam /joist carrying a non - uniform load. 20 Manufactured floor /roof truss design details. ❑ ❑ ❑ 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas - piping schematic is required ❑ ❑ ❑ for four or more appliances. 22 Engineer's calculations. When required or provided, (i.e., shear wall, roof truss) shall be stamped by an engineer or ❑ ❑ ❑ architect licensed in Oregon and shall be shown to be applicable to the project under review. JURISDICTIONAL SPECIFICS , . { . 23 Three (3) site plans are required for Item 11 above. Site plans must be 8 -1/2" x 11" or 11" x 17 ". ❑ ❑ ❑ 24 Two (2) sets each are required for Items 16, 19, 20 and 22 above. ❑ ❑ ❑ 25 Building plans shall not contain red lines or tape -ons. "Mirrored" building plans will not be accepted. ❑ ❑ ❑ 26 "Reversed" building plans must meet criteria outlined in the Permit & System Development Fees document. ❑ ❑ ❑ 27 "Drawn to scale" indicates standard architect or engineer scale. ❑ ❑ ❑ 28 Site plan to include tree size, type and location per approved project street tree plan (if applicable), and City of Tigard ❑ ❑ ❑ Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations, driplines, ❑ ❑ ❑ and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services' Sensitive Area Pre - Screening Site Assessment form is required for all building additions, ❑ ❑ ❑ including decks, patio covers (over non - impervious surface) and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. I:\ BuildingWermits \BUP- RES- PermitApp doe 03/21/06 440 -4613T( 1 1/02 /COM/WEB) Sep. 9. 2008 2:24PM No. 6993 P. 1 • X 47 - 'j CleanWater Services P } � ECE/ � - Our commiment is clear. '° SEP 9 2008 CITY OF TIGARD BUILDING DIVISION September 09, 2008 Walter Bros Construction 11795 SW Tualatin Rd Tualatin OR 97062 RE: Deck addition located at 13505 SW 110 Ave, Tigard, OR CWS file 08-002749 (Tax map 2S103DB Tax lot 01400) Clean Water Services has received your Sensitive Area Certification for the above referenced site. District staff has reviewed the submitted materials including site conditions and the description of your project. Staff concurs that the above referenced project will not significantly impact the existing Sensitive Areas found near the site. In light of this result, this document will serve as your • Service Provider letter as required by Resolution and Order 07 -20, Section 3.02.1. All required permits and approvals must be obtained and completed under applicable local, state, and federal law. This letter does NOT eliminate the need to protect Sensitive Areas if they are subsequently identified on your site. • If you have any questions, please feel free to call me at (503) 681-3605 Sincerely, • Chuck Buckallew Environmental Plan Review Site plan attached 2550 SW Hillsboro Highway a Hillsboro, Oregon 97123 Phnna (ct111 FA1 -1Ann 0 rm.,- ('n1f AR1.3FI1 • winiw rIoanllVaforcan,iroc nrn 1 5)0 ' D 7 " r Z Vila �?(ti(- RECEIVED AUG 2 02003 ortrii) � 6 U LL�DING TIGARD E ,, q _DIVISIo T7,2-(7-1 il "vy ' 3 `� Z�' psi✓ h �- ;,tII i 2' r r t,IetJ ,let k- I z- 1 ti j: i,: ^q bp( 1 Ar i-Ux /ti SD' Z$lo30130 /`f �� r S' ' K } / ,, ` L Sc CI Y OF TIG ' 1 - ' ' LAN REVI W BUILDIN el / ' Street Trees" Approved /�1(J P T 1 ,-� Approved ❑ Not Approved A Notes: < , Date: $ p4D c2 CITY OF TIGARD. SITE LAN REVIEW _ BUILDING PERMIT NO.: !MR ; dr Wes► PLANNING DIVISION: Required Setba5lcs: 2'Approved ❑ Not A roved Side: / Street Side: / I. oot. Ga . age: - Rear: I k 7 visa's, Clearance: (Approved ❑ Not Approved Maximum Building Height ....V. feet � ❑ No p . a .-- -�-- -- - �- �-° �_w' er € rovider Re "fps c qui r r . Yes4� F-1 APPROVAL "�P� 44 ir Illg Received CITY E "t IG PL& DIVISION B : likic a( Jtr• Ct Dat l /ber t ENGINEERING DEPARTMENT: Ir Actual ope: =% ' Approved . __ DP ❑ Not Approved Q�. �pP DATE a l a' - t i� �,�(._ Approved I� A roved By: Date4 8 � e ----- Site PI ; w. Notes: ! `— - >> NOTICE OF TYPE I DECISION lM U THE T (VAR) AD J s N ( AR) 2008 -000v $ %ISA MIRA PARK LOT 10 REAR YARD SETBACK ADJUSTMENT 120 DAYS = 11/21/2008 SECTION I. APPLICATION SUMMARY FILE NAME: MIRA PARK REAR YARD SETBACK ADJUSTMENT CASE NO.: Adjustment (VAR) VAR2008 -00017 PROPOSAL: The applicant has requested a 20% adjustment to the rear yard setback to reduce the setback from 15 feet to 12 feet to accommodate construction of a deck on lot 10 of the Mira Park Subdivision. APPLICANT: Walker Bros. Construction 11795 SW Tualatin Rd., ## 67 Tualatin, OR 97062 OWNER: Joe Jebbia 13505 SW 110 Avenue Tigard, OR 97224 LOCATION: 13505 SW 110 Avenue; Washington County Tax Assessor's Map 2S103DB, Tax Lot 1400. COMPREHENSIVE PLAN DESIGNATION: R Low DensityResidential. ZONING DESIGNATION: R-4.5: Low Density Residential District. The R-4.5 zoning district is designed to accommodate detached single - family homes with or without accessory residential units at a minimum lot size of 7,500 square feet. Duplexes and attached single - family units are permitted conditionally. Some civic and institutional uses are also permitted conditionally. APPLICABLE REVIEW CRITERIA: Community Development Code Chapters 18.370, 18.390 and 18.510. SECTION II. DECISION Notice is hereby given that the City of Tigard Community Development Director's designee has APPROVED the above request subject to certain conditions of approval. The findings and conclusions on which the decision is based are noted in Section IV of this decision. VAR2008 -00017 - SETBACK ADJUSTMENT PAGE 1 OF 3 NOTICE OF TYPE I DECISION r r THIS APPROVAL SHALL BE VALID FOR 18 MONTHS Y' . FPO THE EFFECTIVE DATE OF THIS DECISION i K SECTION III. BACKGROUND INFORMATION Site Information and Proposal Description: The subject parcel is Lot 10 of the Mira Park Subdivision (plat recorded in September 1971) located between SW Park and SW Fairhaven Streets west of Hwy 99. The subject parcel is 8,000 square feet in size. The proposal is to reduce the standard 15 -foot rear yard setback to 12 feet to accommodate construction of a deck SECTION IV. APPLICABLE REVIEW CRITERIA AND FINDINGS COMPLIANCE WITH COMMUNITY DEVELOPMENT CODE SECTIONS: Tigard Development Code Section 18.370.020 allows the following development Adjustments by means of a Type I procedure: Front yard setbacks. Up to a 25% reduction of the dimensional standards for the front yard setback required in the base zone. Setback of garages may not be reduced by this provision. Interior setbacks. Up to a 20% reduction of the dimensional standards for the side and rear yard setbacks required in the base zone. Lot coverage. Up to 5% increase of the maximum lot coverage required in the base zone. The applicant has requested an Adjustment to the rear yard setback to allow construction of a deck The required setback is 15 feet. Provided the following criteria are met, a 3 -foot reduction of this setback may be allowed because it reduces the setback by 20 percent, which is the maximum allowed for interior setbacks. A development Adjustment shall be granted if there is a demonstration of compliance with all of the applicable standards: A demonstration that the Adjustment requested is the least required to achieve the desired effect; The adjustment is being requested to allow a 12 -foot deep deck in the 24 -foot deep rear yard, as indicated on the applicant's site plan. The information submitted by the applicant shows that the proposed setback reduction would be the minimum necessary to achieve the cesired effect. The proposed adjustment request is in compliance with this standard. The Adjustment will result in the preservation of trees, if trees are present in the development area; The proposed deck will replace an existing deck with 2 feet of additional depth, 8 feet above ground. Therefore, this standard does not apply. The Adjustment will not impede adequate emergency access to the site; VAR2008 -00017 - SETBACK ADJUSTMENT PAGE 2 OF 3 NOTICE. OF TYPE I DECISION The proposed rear yard setbac,. adjustment will reduce the setback to �� feet, whereas the minimum setback for fire safety is 3 feet from the property line and 6 feet between buildings. The rear yard of the subject property backs up to a green space approximately 100 feet deep. Therefore, the adjustment will not adversely affect emergency access to the subject dwelling or adjacent dwelling, consistent with this standard. There is not a reasonable alternative to the Adjustment which achieves the desired affect. Alternatives to the proposed adjustment would be to limit the deck expansion. However, as shown above, no public purpose would be served and the desired effect would not be achieved. Therefore, there is no reasonable alternative to the proposed adjustment. FINDING: Based on the analysis above, the adjustment standards have been satisfied. SECTION V. PROCEDURE AND APPEAL INFORMATION Notice: Notice was mailed to the applicant and owners. Final Decision: A setback Adjustment is a Type I procedure. As such, the Director's decision is final on the date it is mailed or otherwise provided to the applicant, whichever occurs first. The Director's decision may not be appealed locally and is the final decision of the City. THIS DECISION IS FINAL ON AUGUST 11, 2008 AND BECOMES EFFECTIVE ON AUGUST 12, 2008. estions : If you have any questions, please call the City of Tigard Planning Division, Tigard City Hall, 13125 SW Hall Boulevard, Tigard, Oregon at (503) 639 -4171. G avu 4 '' Auist 11, 2008 APPROVED BY: ry pagee� DA'1'B AAsociate!Planner VAR200S -00017 - SETBACK ADJUSTMENT PAGE 3 OF 3 NOTICE OF TYPE I DECISION J � �� C ITY of TIGARD • /� \ �\ j' i j i GEOGRAPHIC INFORMATION SYSTEM �� `" ' ; \\ __- v► _ VICINITY MAP / P i VAR2008- 00017 1 1 \ I , , , 37_, , , , , \ ;_____ 1 _ PARK ST MIRA PARK � \--- i SE'1'1�ACK • 5�� I - I ------ - - + ADJUSTMENT G� L ' GS Q �' M I RA C� m n 1 i 71:3 r�� V1/\01.,:r , COOK LN LEGEND: 111 w C 1' IIII �'� r Q j SUBJE v 2 WANE SI ,__ .. 1 _ cl ,__ _ = i1 • :.„, rs_ FAIRHAVEN ST FAIRHAVEN ° 5 , . Tigard Area Map Q - N / FAIRHAVEN 0 60 120 180 240 300 Feet Q 1 "= 248 feet I la _ VI r 7 Gs NT j P L Information on this map is for general location only and [--- ______ should be verified with the Development Services Divisn. -- Trr--- I - - - - T� 13125 SW Hall Blvd I io Tigard, OR 97223 (503) 639 -4171 I _ - 1 I http /lwww.cl.tigard or.us Community Development Plot date: Aug 11, 2008; C: \magic\MAGICO3.APR :,:----;--;.- - CITY OF TIGARD BUILDING DIVISION PERMIT #: IVIST2006-00121 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 9/9/2008 Phone: (503) 639-4171 Aodtapitlt Inspection Requests (24 Hrs.): (503) 639-4175 A f'- i..... INSPECTION WORKSHEET FOR DATE: 9/18/2008 TIME: 7:00AM PAGE: 4 SITE ADDRESS: 13505 SW 110TH AVE CLASS OF WORK: SUBDIVISION: MIRA PARK LOT #: 010 TYPE OF USE: PROJECT NAME: JEBBIA DESCRIPTION: Remove and replace deck, from 340 sq ft to 408 sq ft deck. OWNER: JEBBI A, JOE PHONE #: 503-639-1275 CONTRACTOR: WALTER BROS CONSTRUCTION LLC PHONE #: 503-332-W76 Inspection Request Scheduled For: Date: 9/18/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 299 Final inspection 075642-01 503-332-5076 N VS Corrections /Comments/ Instructions: 6_ 6e- -lie PASS n PARTIAL APPROVAL CANCEL n NO ACCESS I I FAIL fl CALL FOR INSPECTION n ADDITIONAL FEES ASSESSED Inspector: 23-S Date: /8 Sefd g Phone #: (503) 718- 24/23 CITY OF TIGARD BUILDING DIVISION PERMIT #: IVIST20013-00121 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 9/9/2008 Phone: (503) 639-4171 Inspection Requests (24 Hrs.): (503) 639-4175 . ANAtiii! V i*\ „J- AI INSPECTION WORKSHEET FOR DATE: 9/11/2008 TIME: 7:00AM PAGE: 2 SITE ADDRESS: 13505 SW 110TH AVE CLASS OF WORK: SUBDIVISION: MIRA PARK LOT #: 010 TYPE OF USE: PROJECT NAME: JEBBI A DESCRIPTION: Remove and replace deck, from 340 sq ft to 408 sq ft deck. OWNER: JEBBI A, JOE PHONE #: 503639-1275 CONTRACTOR: WALTER BROS CONSTRUCTION LLC PHONE #: 503-332-5076 Inspection Request Scheduled For: Date: 9/1'112008 Pour Time: 2:00 Code # . Inspection Description Confirm # Contact # Message 205 Footing 075380-01 503-332-5076 Corrections/Comments/Instructions: OK QOU 0 PARTIAL APPROVAL 0 CANCEL El NO ACCESS EI FAIL I I CALL FOR INSPECTION 0 ADDITIONAL FEES ASSESSED Inspector: Date: //Se.-5c Phone #: (503) 718- 2.11XI