Plans hl CITY OF TI ARD CITY OF TIGARD !t App roved [ v III `ti Conditionally Approved [ ] Building Division • .-, '6,-: ( ] 13125 SW Hall Blvd. - %,_ ,•, See Letter to : Attach Tigard, OR 97223 a h: x ,, Permit N b- . r: 2 - 0 - 503 C r . , Ad, r- ss• e ' o �i�'� www.tigard- or.gov k 1 h B y r ��► Date: �� MN . OFFICE COPY 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof - Mounted PhotoVoltaic Solar Panel System PftiOilitiVili Installation address: . 6 4 1 City: t`6 �, ��i ;� Zip: 1 Owners na - /� Contractors name: c J Contractors CCB number: iC' T 110 a... 4 If "Yes ", does not Flood Hazard Area Is the installation ❑ Yes qualify for the located in a flood prescriptive path, plain/ flood way °t follow OSSC or ORSC for design requirements. Wind Exposure Is the wind "t7-Yes If "Yes ", qualifies for exposure "C" or less No the prescriptive path. Installations on Is the Ground Snow If "Yes ", qualifies for detached single/ Load 70 psf or less. the prescriptive two- family dwelling/ path. path. Ground Snow single/ two - family Load townhomes and /or ❑ No their accessory structures. Installations on all Is the Ground Snow If "Yes ", qualifies for t structures other Load 50 psf or less. the prescriptive or than above ,� v ,,, path. .� tco ❑ No Is the construction material wood and ,L.Yes If "Yes ", qualifies for does the Type of constructions qualify Li No the prescriptive Construction as "conventional path. ry light frame" . construction? Is the spacing 24 If "Yes ", qualifies for Pre - engineered inches or less. the prescriptive trusses. -Yes path, Roof framing ❑ No members Is the spacing 24 If "Yes ", qualifies for Nominal lumber inches or less. the prescriptive Yes path. ❑ No Is the combined 'Yes If "Yes ", qualifies for weight of the PV the prescriptive modules and ❑ No path. racking less than or Solar installation equal to 4.5 psf. Is the solar installation layout in accordance with Yes If "Yes ", qualifies for s Section 305.4(3) of o No the prescriptive the 2010 Oregon path. Solar Code. o Metal Check the type of ❑ Single layer of If roofing material is roofing material. wood shingle/ shake one of the three ,Max. Two layers types checked, Roofing material qualifies for the of composition prescriptive path. shingle. Is the roof mounted .,Yes If "Yes ", qualifies for Connections of the solar assembl o No the prescriptive solar assembly to connected to roof path. the roof framing or blocking directly. Attachment of roof Is the gauge 26 or N o Yes If "Yes ", qualifies for mounted solar less? ❑ No the prescriptive systems directly to \\A-\ path. d standing seam metal panels Page 2 of 4 115 lbs for 60 inch If "Yes ", qualifies for Minimum Uplift spacing or less the prescriptive rating of Clamps: ❑ Yes path. ❑ No 75 lbs for 48 inches If "Yes ", qualifies for spacing or less the prescriptive ❑ Yes path. ' ❑ No If the spacing falls • `\ Spacing of clamps? Minimum 24 inches within 24 inches and 60 inches, qualifies in Maximum 60 inches for the prescriptive path. • If the width of the ' Width of roofing 18 inches or less panel is less than panels? 18 inches, qualifies for the prescriptive in path. ❑ Yes . Size and spacing of Minimum #10 at 24 ❑ No • fastener? inches o/c If "Yes ", qualifies for the prescriptive path. Is the roof decking o Yes If "Yes ", qualifies for of WSP min. ' /2' o No the prescriptive thickness, decking path. a connected to framing members w/ min. 8d nails @ 6 "/12" o /c. Maximum 18 inches Is the height less . If "Yes ", qualifies for Height of the solar from the top of the than or equal to 18 the prescriptive modules module to the roof inches path. surface ❑ Yes ❑ No • • Page 3 of 4 SO ! 4 p nts r r for, r_est.r pave Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. • Minimum size of the plan is 8.5x11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. Structural System must be shown in sufficient detail and clarity to assess whether it Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5x11 inches. • Manufacturer: 't)cetear * Model Number: 240 (b( L eu. * Listing Agency: U�,�,,.. - 03 • f Page 4 of 4 LABELS ELECTRICAL NOTES GENERAL NOTES LEGEND ABBREVIATIONS PHOIOYOLIAIG POINT OF IKItRCONN[CI ION — T WARNING! ELECTRIC SHOCK HAZARD! 1. WHERE ALL TERMINALS OF THE 1. THIS SYSTEM IS GRID- INTERTIED VIA A UL- LISTED O (E) UTILITY METER A AMPERE ( 1) " � I K ,«,.« m ~ A DISCONNECTING MEANS MAY BE ENERGIZED POWER- CONDITIONING INVERTER. AC ALTERNATING CURRENT IN THE OPEN POSITION, A SIGN WILL BE 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. GRID -TIED INVERTER BLDG BUILDING uMG URA PROVIDED WARNING OF THE HAZARDS PER 3. ALL INVERTERS AND ARRAYS ARE NEGATIVELY GROUNDED. ® CONC CONCRETE T1GP.RD SOIarCilly — — = ART. 690.17. 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. DC C COMBINER BOX CI'T. CF PHOTOVOLTAIC AZ DISCONNECT 2. EACH UNGROUNDED CONDUCTOR OF THE 5. ALL WORK TO BE DONE TO THE CURRENT UBC. F.,-._4 DC DISCONNECT D DISTRIBUTION PAN�lJ1LD ARNING! ELECTRIC SHOCK HAZARD! MULTIWIRE BRANCH CIRCUIT WILL BE 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT AC DC DIRECT CURRENT OPERATING VOLTAGE V IDENTIFIED BY PHASE AND SYSTEM PER NATIONAL ELECTRIC CODE AS AMENDED BY THE OREGON I—'.-1 AC DISCONNECT EGC EQUIPMENT GROUNDING CONDUCTOR 2 MAXIMCUUM RREN OPERT ATING A ART 210.5. ELECTRICAL SPECIALTY CODE. EXISTING 3. ANATIONALLY- RECOGNIZED TESTING 7. WEEBS ARE A ONE TIME USE ITEM. c COMBINER BOX (E) LABORATORY SHALL LIST ALL EQUIPMENT IN EMT ELECTRICAL METALLIC TUBING SolarCity •' .I,' t ':COH COMPLIANCE WITH ART. 110.3. O DISTRIBUTION PANEL G SOLAR GUARD METER ta. • PHOTOVOLTAIC DC DISCONNECT 4. CIRCUITS OVER 250V TO GROUND SHALL G GALVANIZED WARNING! ELECTRIC SHOCK HAZARD! COMPLY WITH ART. 250.97, 250.92(B) GEC C GROUNDING ELECTRODE CONDUCTOR Voc V 5. DC CONDUCTORS EITHER DO NOT ENTER INDEX ® SOLAR GUARD GATEWAY HDG HOT DIPPED GALVANIZED (,;) ;x A BUILDING OR ARE RUN IN METALLIC PHOTOVOLTAIC MODULE I CURRENT Imp A RACEWAYS OR ENCLOSURES TO THE FIRST PV1 COVER SHEET — Imp CURRENT AT MAX POWER SolarCity .w.:.o1�:,',' - ACCESSIBLE DC DISCONNECTING MEANS PER PV2 SITE PLAN • (E) VENT PIPE INVS INVERTERS ART. 690.31(E). PV3 STRUCTURAL VIEWS Isc SHORT CIRCUIT CURRENT 6. ALL WIRES SHALL BE PROVIDED WITH PV4 UPLIFT CALCULATIONS (E) SKYLIGHT kVA KILOVOLT AMPERE Solar Disconnect STRAIN RELIEF AT ALL ENTRY INTO BOXES PV5 SINGLE LINE kW KILOWATT AS REQUIRED BY UL LISTING. PV6 ELECTRICAL CALCULATIONS (E) CHIMNEY LBW LOAD BEARING WALL 4) 7. MODULE FRAMES SHALL BE GROUNDED AT PV7 CUTSHEETS MIN MINIMUM 1 • WARNING- Electrl ockHazard PV8 CUTSHEETS DO NOT TO • RMINALS THE UL- LISTED LOCATION PROVIDED BY THE NEW Terminals on D • and Load sides MANUFACTURER USING UL LISTED PV9 CUTSHEETS LICENSE NEC NATIONAL ELECTRIC CODE may De enen ed m ,h• open PDSltfon. GROUNDING HARDWARE. NIC NOT IN CONTRACT 8. ALL EXPOSED METAL PARTS (MODULE OR # 180498 NTS NOT TO SCALE DC Disconnect FRAMES, RAIL, BOXES, ETC.) SHALL BE OC ON CENTER GROUNDED USING UL LISTED LAY -IN LUGS P PANEL BOARD LISTED FOR THE PURPOSE. POSTS SHALL BE PL PROPERTY LINES WARNING - EIectTr oc Hazard MADE ELECTRICALLY CONTINUOUS WITH VICINITY MAP PV PHOTOVOLTAIC (5) DO NOT TO CH RMINALS T erminals on b . e and load sides ATTACHED RAIL. — PVC POLYVINYL CHLORIDE may be enen• n Iho Open Position 9 MODULE FRAMES, RAIL, AND POSTS SHALL S SUBPANEL BE BONDED WITH EQUIPMENT GROUND _n, Wand5 SCH SCHEDULE DC VOUSCF IS SIrars PRE SS NT wN[N CONDUCTORS AND GROUNDED AT THE MAIN ('I Mernorial Pi I SS STAINLESS STEEL SOLAR MODULES ARE EXPOSED TO SUNLIGHT ELECTRIC PANEL. SSD SEE STRUCTURAL DRAWINGS 6 10. IF THE EXISTING AC GROUNDING ELECTRODE , 5 Fcrry Rd Crestwood STC STANDARD TESTING CONDITIONS ) WARNING -Dual Power Sour Seco sourco Is photovoltaic system IS A COPPER ROD, THE DC GEC SHALL BE 4 �' T SWI SOLAR WATER HEATER J EITHER #8 THWN -2 RUN INSIDE CONDUIT nreernvF ,,,,,. TYP TYPICAL 7) WARNING - Electric " ° ` ° " Shock HazaL BONDED AT BOTH ENDS, OR #6 BARE Park UP UON UNLESS OTHERWISE NOTED ( ) �" ' " "d r< COPPER RUN ALONG BUILDING AS LONG AS UPS UNINTERRUPTIBLE POWER SUPPLY � Contact authorized servic r for assistance �1 , � '.� IT IS NOT SUBJECT TO PHYSICAL HARM PER V VOLT r CAUTION 8 ART. 250.166(8) &(C), 250.64(8) &(E). IF _ Vmp VOLTAGE AT MAX POWER ` THE EXISTING AC GROUNDING ELECTRODE ISe #��� II� Park Voc VOLTAGE AT OPEN CIRCUIT PV COMBINER Box A CONCRETE- ENCASED ELECTRODE, THE DC ��� �' W WATT (9) WARNING: , GEC SHALL BE A #6 THWN -2 PER ART. I 3R NEMA 3R, RAINTIGHT ELECTRIC SHOCK HAZARD 250.166(D). THE GEC SHALL BE Ix C WARNING ` CONTINUOUS AS DESCRIBED IN ART. no ELE SHOCK HAZARD IF AGR•: 250.64(C). '' Le' ser REV BY DATE COMMENTS ( 1.0 ) F AYLT IG INDICATGD TMG NORMAL . , 'T' GROUNDED CONDUCTORS MAY BEE - ,x GIZED AND UNGROUNDED r ' , S ` ' City Perk REV * 4 4 / 4 / * * f . • ( 11 ) W ARN ING C_>ty�,�,' . e., Y I NVERT ER OUTPUT CONNECTION `4 DO NOT RELOCATE c•+4 THIS OVER CURRENT DEVICE ¢ S P T r , . MARKET: MOOULES: PREMISE OWNER: DESCRIPTION: JOB NUMBER: X44 CONFIDENTIAL - THE INFORMATION HERON .,„ of ,,e, CONTAINED SHALL NOT BE USED FOR THE RESI (26) KYOCERA # KD210GX -LPU OLNEY, JERRY A OLNEY RESIDENCE JB- 972396 00 S= BENEFIT OF ANYONE EXCEPT SOLARCITY INC., DESIGN: MOUNTING SYSTEM: 10460 SW 72ND AVE 5.46 kW ROOF MOUNT PV SYSTEM S o l arCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN JS SOLARCITY CANOPY -C AND RAIL PART TO OTHERS OUTSIDE THE RECIPIENTS DATE ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MERU: PORTLAND, OR 97223 3/25/2011 THE SALE AND USE OF THE RESPECTIVE * (1) FRONIUS # IG PLUS 5.0 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: San Mateo, CA T;(650) 638-1028 I F:(650) PAYMENT TYPE 0) 638 -1029 PERMISSION OF SOLARCITY INC. LEASE 5035457074 COVER SHEET PV 1 (888)-50L-CITY (765-2489) I www.solaraty.com SITE PLAN Scale: 1/8" = 1' } N 10' 0% ©fl TO R W l E -\ t - + I ,- -\ I I I 90' . 1 , Inv; M 4 D;; r TOR TO I ~ W. 8 ATTACHMENTS SHALL BE SPACED NO NOTE GREATER THAN 24 INCHES ON CENTER ARRAY AREA: 428 SQ. FT. IN ANY DIRECTION WHERE ARRAY IS TOTAL ROOF AREA: 3591 SQ. FT. LOCATED WITHIN 3 FEET OF A ROOF 12% ROOF COVERAGE BY ARRAY EDGE, HIP, EAVE OR RIDGE. O6ISC 306.4.3 (B) MP1 ROOF MOUNT PITCH: 25 ARRAY PITCH: 25 7 STRUCTURE AZIMUTH: 180 _ARRAY AZIMUTH: 180 CHANGE MATERIAL: Comp Shingle Roof Q 1 MIN. STORY: 1 o FIRE SETBACK RAFTERS N (�) SIZE: 2x4 `' SPACING: 24" O.C. FRONT OF S UPPORT: 2x4 WEB MEMBER X. HOUSE I NOTES PLYWOOD SHEATHING l B PV3 SHEET NOTES 1® INVERTER, DC DISCONNECT, & WARNING LABELS(3),(4),(5),(6; (2) DEDICATED PV SYSTEM METER. 0 NOT USED. ® UTILITY METER (6). A ® NOT USED. I PV3 © NOT USED. NOTE 0 NOT USED. 45' MP1B IS NOT USED. RAFTER SPANS ARE ® DISTRIBUTION PANEL & WARNING LABELS (1),(2). TO TOO LONG. 9® NOT USED. 0 1' 8' 16' 1 ®. CONDUIT ROUTED ON ROOF Q NOT USED. :_�∎ REFER TO PV1 FOR WARNING LABELS. CONFIDENTIAL — THE INFORMATION HERON MARKET: MODULES: PREMISE CANTER: DESCRIPTION: JOB NUMBER 10 J B -9 72396 00 114 CONTAINED SHALL ` NOT BE USED FOR THE RESI (26) KYOCERA # KD210GX -LPU OLNEY, JERRY A OLNEY RESIDENCE : ; .: BENEFIT OF ANYONE DISCLOSED SOLARCITY INC., DESIGN: MWNTING SYSTEM: A S oIartity NOR SHALL IT BE DISCLOSCLOS ED D IN IN WHOLE OR IN �S SOLARCITY CANOPY -C AND RAIL 10460 SW 72ND AVE 5.46 kW ROOF MOUNT PV S " PART TO OTHERS OUTSIDE THE RECIPIENT'S DAIS ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER INVERTER: PORTLAND, OR 97223 3/25/2011 NE SALE AND USE OF THE RESPECTIVE * (1) FRONIUS # IG PLUS 5.0 3055 CIearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT PAGE NAME: SHEET: REV: San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. TYPE 5035457074 T:(650) 638 -1028 I F:(650) 638 -1029 LEASE SITE PLAN PV 2 (888)-50l-CITY (765-2489) I www.solarcity.com 4' BETWEEN FOOTINGS 4' BETWEEN '� FOOTINGS 'I 1 It if , F — r ,�, N N N N 1 2' TYP- (E) 2x4 TOP CHORD @ 24" SPACING B FRONT VIEW OF MOUNTING PLANE Scale: 1/2 " =1' -0" ATTACHMENTS SHALL BE SPACED NO GREATER THAN 24 INCHES ON CENTER IN ANY DIRECTION WHERE ARRAY IS LOCATED WITHIN 3 FEET OF A ROOF O 1 "- STANDOFF EDGE. HIP, EAVE OR Ri0(iE - Scale: 1 1/2" = 1' 0 305.4.3 (B) (E) 2x4 TOP CHORD SOLAR PANEL INSTALLATION ORDER ATTACHED WITH MODULE / LOCATE RAFTER, MARK HOLE IIII CLAMPS, ' -16 BOLTS, ( LOCATION, AND DRILL PILOT (E) 2x4 AND CHANNEL NUT HOLE. CUT SHINGLE AROUND TRUSS SOLARCITY SOLAR RAIL \ FLASHING COLLAR. (E) 2x4 WEB & BOLT ( - SEAL PILOT HOLE AND BOTTOM MEMBER ♦„ CANOPY BOLT ASSEMBLY 1 a ( 3 ) (2) OF CANOPY BASE WITH .11 - . \7 POLYURETHANE SEALANT. CANOPY FLASHING / LAG CANOPY BRACKET IN & BRACKET (3) RAFTER WITH (1) A DIA. LAG 4 1: i (E) COMP. SHINGLE - �� POST. � BOLT IN HOLE CLOSEST TO �` (E) ROOF DECKING - NSTALL CANOPY FLASHING ONTO -4 8' -1" / 6' -5" / 7' / (E) 2x4 BOTTOM " DIA LAG BOLT ( BRACKET. ATTACH RAIL WITH M (E) LBW TOP CHORD: 2x4 © 24" O.C. CHORD (2- " EMBED, MIN) CANOPY CLAMP. SUPPORT: 2x4 WEB MEMBER MAX SPAN: 8' -1" (E) RAFTER A SIDE VIEW OF MOUNTING PLANE 1A • Scale: 1/4 " =1' -0" CONFIDENTIAL - THE INFORMATION HEREIN YARIET. NODULES PREMISE CANER DESa�IIOk JOB MIR = %kit / CONTAINED SHALL NOT BE USED FOR THE R EST (26) KYOCERA # KD210GX —LPU OLNEY, JERRY A OLNEY RESIDENCE JB- 972396 00 It $ 0.01 ORGANIZATION, EXCEPT IN CONNECTION WITH �TETk P ORTLAND, OR 97223 EENEFlT OF ANYONE EXCEPT SOLARCITY INC., ak MOUNTING SY G ak °if NOR SHALL IT BE DISCLOSED N WHOLE OR IN jS SOLARCITY CANOPY —C AND RAIL 10460 SW 72ND AVE 5.46 kW ROOF MOUNT PV SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'S s PRQECT MANAGER 3/25/2011 THE SALE AND USE OF THE RESPECTIVE * ( FRONIUS # IG PLUS 5.0 3055 Mateo, CA 94402 Way SOLARCITY EQUIPMENT, WITHOUT 111E WRITTEN PAYMENT TYPE PAGE NAYS SHEET. T:(650) 638 028 I CF 160)638 - 1029 PERMISSION O F SCLAROTY INC. L EASE 5035457074 STRUCTURAL VIEWS PV 3 (888)- 501-2 I www.soIatity.com UPLIFT CALCULATIONS Input Variables Calculations and Values Required Variables Design wind pressures based upon: Mean roof height: 15 ASCE 7 -05 Chapter 6 Wind Loading Exposure category: B Basic wind speed (or city in the future): 110 Equation 6.5.13.3: Component and Cladding Elements Importance factor (1 for residential): 1 Wind pressure P = qh *Cn *G Roof shape: pitched 6.5.10: Velocity pressure Roof angle (degrees): 25 qh = 0.00256 *Kz *Kzt *Kd *VA2 *I Roof zone: 2 Contiguous sq. feet of array: 80 From Table 6 -3: Least width of the building: 52 Kz = 0.70 Obstructed wind flow? TRUE From Figure 6-4: Kzt = 1.00 Local Topograhphical Features From Table 6-4: (choose "standard "or refer to pictures right. and below) Kd = 0.85 Type of hill: none From figure 6 -1: Hill height (h) (ft): V = 110 Slope of hill (degrees): From table 6 -1: Horizontal distance from hilltop to house (x): I = 1 eight from bottom of hill to mean roof height (z): From Velocity Pressure Equation: qh = 18.43 Design Wind Pressures From Figure 6 -19B P (lbs. per sq. ft.) = qh *Cn *G Cn (uplift) _ -2.00 Pd (downforce pressure) = 12.53 Cn (down) = 0.80 Pu (uplift pressure) = -31.33 From 6.5.8.1 G = 0.85 Max Tributary Area Feet Inches Individual Rows in Portrait X (E -W distance between standoffs) = 4 0 Kyocera KD210GX -LP I Y (N -S distance between standoffs) = 2 6 Amax (sq. ft.) = 0.5 *L *X L (length of panel in ft. perpendicular to rail) 4.93 X= 4.00 Module Rail Max. Span / Cantilever (in) = 74 34 1/2 Y = 2.50 Max Uplift Force on a Single Standoff L = N/A Pmax (Ibs.) = Amax *Pu Amax = 9.85 Pmax = -309 Factor of safety = FI *D *NI /Pmax 250 = Fl (pullout capacity of lag (lbs/inch)) Dead Load Calculations 2.50 = D (minimum lag thread depth) DL (lbs/sq. ft.) = (Mm +Mh) /(L*W) 1 = NI (number of lags per standoff) L (length of Kyocera KD210GX -LP modules) 4.93 2.02 = Factor of safety W (width of Kyocera KD210GX LP modules) 3.25 Mm (weight of Kyocera KD21OGX LP modules) 40.80 Point Load Calculations Mh (weight of hardware per module) = 7.97 PL (Ibs) = Amax *DL I PL= 30 DL = 3.05 Version 6_8 CONFIDENTIAL THE INFORMA71ON HERON MARKET: MODULES PREMISE MINER DESIMPTION: JOB NUMBER: , 6 ∎44 CONTAINED SHALL NOT BE USED FOR THE RESI (26) KYOCERA # KD210GX -LPU OLNEY, JERRY A OLNEY RESIDENCE J B-972396 00 �- SoiarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., DESIGN: MOUNTING sYSTEU: 10460 SW 72ND AVE ' 5.46 kW ROOF MOUNT PV SYSTEM NOR SHALL IT BE DISCLOSED IN WHOLE OR IN jS SOLARCITY CANOPY -C AND RAIL PART TO OTHERS OUTSIDE THE RECIPIENT'S DATE ORGANIZATION, EXCEPT IN CONNECTION Will PROJECT MANAGER: WRIER: PORTLAND, OR 97223 3/25/2011 THE SALE AND USE OF THE RESPECTIVE * (1) FRONIUS # IG PLUS 5.0 3055 Clearview Way 94402 SOLARCITY EQUIPMENT, NITHOUT THE WRITTEN PAYMENT TYPE: PAGE NAME SHEET: REV: T:(650) 638 at I CA 944) 6381029 PQ7AISSION OF SOLARCITY INC. LEASE 5035457074 UPLIFT CALCULATIONS PV 4 (888)- SOL -CfTY(765 -2489) I www.soIarcity.corn MODULE VOLTAGE RATINGS Voc: 33.2 VDC Vpmax: 26.6 VDC LINE DRAWING *MODULE CURRENT RATINGS ARE SHOWN AS In AND Imp IN THE DC A STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. 26 MODULES ON MP1A Dc. nnnnnnnn/ilnnnn DC METER NUMBER:IN24540039 1111 1111 1111 lig 1111 :41 1111 1111 1111 Nil Nil ilIl Nil -- I r - {_ -- r - -- - - -- -- -- -- - -- - - -- -- - GND I 4, I � 1 AWG AW6 -#6 #10, Stranded USE -2 /RHW -2Bare Copper , Black AWG #6, Stranded Bare Copper (1) IGEC I DC+ i o� , nn nnn we. re n n n D� _ • ( 1 Conduit Kit; 3/4" EMT Ground Rod; 5/8" x 8 , Copper 1 Z� Z� Z Z Z� Z Z Z Z Z � / pP ( ) ; W • Voc = 431.6 VDC � I I �- -- - -- - - -- -- - -- - - -- -- - - - -� ' , • Vmp = 345.8 VDC • Isc = 8.58 ADC • Imp = 7.9 ADC (N) ARRAY GROUND PER 690.47(D). I I (26) KYOCERA # KD210GX -LPU I ( P NOTE: PER EXCEPTION NO. 2, ADDITIONAL ' ' PV Module; 210W, 189.8W PTC I I ELECTRODE MAY NOT BE REQUIRED ; I I f" I (1)SHOALS # STG.ICU.M4.F DEPENDING ON LOCATION OF (E) ELECTRODE. I i i Connector; MC4 U -Joint Connector, Female L. -I FRONIUS # IG PLUS 5.0 ( 1 ) I I — (1 ) SHOALS # STG.ICU.M4.M Inverter; 5000W, 277V/240V/208V, 96 %/95.5 %/95.5% EFF. I ' Connector; MC4 U -Joint Connector, Male (E) 200A MAIN ELECTRIC SERVICE PANEL LABEL INVERTER: A EGC DC - DC+ LOCATED UNDER ARRAY (E) WIRES & CONDUIT (E) 200A MAIN CIRCUIT BREAKER INSIDE I I r I I I I I I I I I z-- (1) CUTLER-HAMMER # BQC230230 INVERTER i_ _._L v o 2) AWG #10, USE -2 /RHW -2, Black •� Breaker; 30A -30A, Quadplex (2x2 Pole), Common Trip I ©i GND GFP _ 1 i °— 1 AWG #6, Stranded Bare Copper EGC (E) LOADS PV BACKFEED I I ; 1 Conduit Kit; 3/4" EMT • •-- AC DISCONNECT -. N I Dc+ IDC- IEGC • Voc = 431.6 VDC 1 + PER ART. 690.17 I I ; I I I I • Vmp = 345.8 VDC R3 �� A I I I I EEGC I I • Isc = 17.16 ADC • B I I L_ _ DC • Imp = 15.8 ADC L_ - - L - - DC+ BOTTOM ~ TOP /'� Li I I 1 �-1 N f-^ N _ EGC /GECJ ( 2)FRONIUS # 42,0201,2923 - z GC /GEC �_ E Inverter Input String Combiner 1 \ \ — (2) T &B ADR2 + G EC Lay In Lug; 1 Hole Mount, 2 -14 AWG ,_ \ 1 AWG #10, THWN -2, Black #8 JUMPER GE # I -70S (1) o — 1 AWG #10, THWN -2, Red DC DISCONNECT Meter; FORM 2S 1 AWG #10, THWN -2, White NEUTRAL INTEGRATED INTO COOPER # B Line Meter Socket 011 ( 1 ) — INVERTER; COMPLIES I TO 120/240V BOND (N) #6 EGC /GEC TO (E) = Meter Socket; 125A, 4- 14AWG, Ring Type — 1 AWG #6, THWN -2, Green EGC /GEC WITH NEC. SINGLE PHASE EUFER OR (E) GEC IN MOUNTED INSIDE AT INVERTER — (1 Conduit Kit; 3/4" EMT UTILITY SERVICE PANEL WITH IRREVERSIBLE • Vmp = 240 VAC CRIMP PER ART. 250.64(C) • Imp = 20.8 AAC CONFIDENTIAL THE INFORMATION HERON MARKET: MODULES PREMISE ONNER DESCRIPTION: JOB NUMBER ' ∎ �� 4 CONTAINED SHALL NOT BE USED FOR THE REST (26) KYOCERA # KD210GX -LPU OLNEY, JERRY A OLNEY RESIDENCE JB- 972396 00 :; , � BENEFIT OF ANYONE EXCEPT SOLARCITY INC., DESIGN: MOUNTING S1S1EM NOR SHALL IT BE DISCLOSED IN WHOLE OR IN JS SOLARCITY CANOPY -C AND RAIL 10460 SW 72ND AVE 5.46 kW ROOF MOUNT PV SY ,� � �SolarCity PART TO OTHERS OUTSIDE THE RECIPIENTS DATE ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: INVERTER: PORTLAND, OR 97223 3/25/2011 THE SALE AND USE CF THE RESPECTIVE * (1) FRONIUS # IG PLUS 5.0 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: San Mateo, CA 94402 PAYMENT TYPE PERMISSION OF SOLARCITY INC. T:(650) 638 -1028 F:(650) 638 -1029 LEASE SINGLE LINE PV 5 (888)- SOL-CITY (765 -2489) I www.solarc,ty.com 1. Conductor must per Art .8(8)(1) ELECTRICAL CALCULATIONS a. Conductor must t deg. 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). Module: 26 Kyocera KD210GX -LPU 1891 Inv Pwr W PTC Voltage Drop Calculations Version 5_7 3 b. Conductor must have (after corrections for conditions of use) >= Inverter t 1 Fronius IG Plus 5.0 -1 (240} 95.S 5,000_ Vdrop = mp) • (2 * Length)' (Resistance) / (Vmp) . continuous current per Table 310.16. Module: Imp (A) Max- Length (ft) Wire Inverter 2 String: 7.9 40 I AWG 1C at Max Ave Hi: 80 deg F Module- Vdrop = (7 -90 A * 80 ft *0.00124 Ohms) 1 317 V = 0 25% c. Evaluate conductor temperature at terminations per 110 . 14 (C). Inverter 3: Branch: I 15.8 I 60 IC AWG to at Max Ave Hi: 80 deg F . Ampacity of wire derated for conditions of termination must be Module: Vdrop = (15.80 A k 120 ft * 0.00124 Ohms) I 317 V = 0.74% >= continuous current *1.25. All string terminations are rated at Inverter 4: Total voltage drop in DC conductors =10.99 %1 90' C. Inverter. I 20.80 I 10 lc AWG 'ICI at 240V Total: modules Total Inv Pwrir 111111111111111.111PTC Vdrop = (20.80 A * 20 ft ' 0.00120 Ohms) l 240 V 0.21% 2. OCP Sizing per Art 690.8(B)(1) • I , • r..' . .. i . . i . ' •.t.: Total STC 5,461 Combined! 20.83 I 0 IC AWG 1fr1 at 240V a. Round up to next size per Art 240.4(B) Vac= V deg F d- 8 C Vdrop = (20.83 A • 0 ft *0_00120 Ohms) l 240 V 0.00% Vmp= V Record Low Temp: 8 Total voltage drop in AC conductors = 0.21% 3. Conductor Sizing per Art 690.8(6)(1) lsc= A Max Average Hi Temp= 80 " �::: p ' : : � Total voltage drop in AC and DC conductors = 1.20% 1 : ; ,;; - a. Conductor must have 30 deg. C ampacity >= 125% of continuous Imp= A Record Hi Temp: 106 41.11•1 Tvoc= Vfdeg C current per Art 215.2(A)(1). Tisc= mAjdeg C I String Type A and 2 Combined Strings Type A Voc Correction Method: Table 690.7 Branch Circuit Type A 13 modules per series string b. Conductor must have (after corrections for conditions of use) >= Fronius IG Plus 5 0-1 (240) Voc Correction Factor_ 1.0, 2 strings per branch 1-way wire length: 60 ft continuous current per Table 310.16. 13 Kyocera KD210GJlLPIJ Inverter Min Vdc Input: Vdc Voc= 431.6 V Min Vmp at Max Temp: OT Vdc Voc= 431.6 V c. Evaluate conductor temperature at terminations per Art 110.14(C). Vmp = 345.8 V Max Voc at Min Ternp. , Vdc IVmp= 34.5.8, V Ampacity of wire derated for conditions of termination must be In= 8.50 A Inverter Max Vdc Input: Vdc 1st= 17- A >= continuous current *1.25. All branch terminations are rated at Imp= 7.9 A Max String Size: Imp= A 75' C min. Icont= 10.73 A Art 690.8(AX1) 1-way wire length: 40 ft Ic on t= 2 A Art 690.8(Ax1) 1.a Tr C AMC?' 10 USE- 2JRHW -2 at 90 deg C: Table 310.16 3.6 Try 1 : THWN- 2IUSE -2 at 90 deg C: Table 310.16 Icont * 1.25 = (Amps) 4. OCP Sizing Icons " 1 2n = (Amps; 13.41 30 deg C ampacity = I a. Round up to next size per Art 24-0.4(B) 30 deg C ampacity = 40 3.b lcont= (Amps) 1.b !cant= (Amps! 10.73 Start ampacity 5. Conductor Sizing per Art 690.8(B)(1) start ampacity 40 Temp- derate (96 =F) - '' - -- a. Conductor must have 30 deg. C ampacity >= 125% of continuous Temperature derate ( % =F) 0.58 end. fill derate ( % te r) y ` Zvi current per Art 215.2(A)(1). Conduit fill derate (%) 1 Derated ampacity I Derated ampacity 23.20 Term 1 Term 2 b. Conductor must have (after corrections for conditions of use) >= Temp table continuous current per Table 310.16. 1.c Icont *125= (Amps: 13.41 3.c Icont*1 25= (Amps) Ampacity 40 Ampacity c. Evaluate conductor temperature at terminations per Art 110.14(C). I I Ampacity of wire derated for conditions of termination must be 2 Icons • 1.25 = (Amps) " 13 3.d OCP size = >= continuous current *1.25. All inverter output terminations are OCP size = 15 , Combined Inverter Outer rated at 75' C. Service Voltage= 240 Volts Inverter Type A Output Total Inverter Power= Watts 1 -way wire length: 0 ft 6. OCP Sizing Fronius [GM, 5.0 (240) 1-way wire length: 10 ft Icont = # of irwerters max inverter current Art 690.8(AX1) a. Round up to next size per Art 240.4(B) Icont= A Art 690.8(AX1) Icont = (Amps) . 4 Icont *125 = (Amps) 26 00 A Art 690 8(BX1) 6 (cant "1.25 = (Amps) -' • 1'A Art 690.8(8x1) 7. Conductor Sizing per Art 690.8(B)(1) OCP size = 3Q Art. 240.6(A) OCP size = A Art. 240.6(A) a. Conductor must have 30 deg. C ampacity >= 125% of continuous 5.a Try C AWG 10 THWN -2 at 90 deg C: Table 310.16 l.a Try `} : THWN - at 90 deg C Table 310.16 current per Art 215.2(A)(1). !cant • 1.25 = (Amps) Icont* 1.26 = (Am Amps) 4 30 deg C ampacity = 40 I 30 deg C ampacity = _ 40 • b. Conductor must have (after corrections for conditions of use) >= 5 . b lcont= (Amps) 20.80 7.b Icont= (Amps) 20 83 Start ampacity 40 Start ampacity 46" continuous current per Table 310.16. Temperature derate (96=F) J.91 Temp. derate ( % =F) 0 91 Conduit fill derate ( %=t) int 1 Cndt_ fill derate ( %_# 1 c. Evaluate conductor temperature at terminations per Art 110.14(C). Berated ampacity 36.4 I Berated ampacity 36.4 I Ampacity of wire derated for conditions of termination must be 5.c Icons "1.25= (Amps) 26.00 7.c Icont *1.25= (Amps) 25.04 - >= continuous current *1.25. All inverter output terminations are Ampacity 35 Ampacity 35 - rated at 75' C min. CONFlDEN11AL - THE INFORMATION HEREIN MARKET: MODULES : PREMISE OVER DESCI PIOR JOB NUMBER _ : 1 CONTANED SHALL NOT BE USED FOR THE RESI (26) KYOCERA # KD210GX -LPU OLNEY, JERRY A OLNEY RESIDENCE JB- 972396 00 ; , BENEFIT OF ANYONE EXCEPT SLUMP( INC., OMR MOONING SISTER 5.46 kW ROOF MOUNT PV SYSTEM ° �� S oiarCity. ei NOR SALL IT BE DISCLOSED N WHOLE OR IN JS SOLARCITY CANOPY -C AND RAIL 10460 SW 72ND AVE � PART TO 01HERS OUTDE THE RECIPIENTS DAZE ORGANIZATION, EXCEPT IN CONNECTION W11H PROJECT MANAGER �1t PORTLAND, OR 97223 THE SALE AND USE CF THE RESPEC11VE * i n FRONIUS # IG PLUS 5.0 3/25/2011 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT DE WRITTEN PAYMENT TYPE: PAGE NAME SHEET T:(650) 63a M a t I C 9 9 4 50 638 -1029 PERMISSION OF SOLARCITY INC. LEASE 5035457074 ELECTRICAL CALCULATIONS PV 6 (888)-501-CITY (765 -z4a9) I www.solardty.com PV MODULE �a °° � � KD21OGX -LPU Ao ..1t � C� KY 0 C E R2 ELECTRICAL CHARACTERISTICS a Current - Voltage characteristics of Photovoltaic Current - Voltage characteristics of Photovoltaic t e ow Module KD210GX -LPU al various cell temperatures Module KD210GX -LPU at various irradiance levels � Q , Cal c e p CUTTING EDGE TECHNOLOGY ""°"�"" """ � '"` 210 WATT Asa pioneer with 35 years in solar. Kyocera demonstrates • �.. leadership in the development of solar energy products. ' '` mrr� HIGH EFFICIENCY MULTICRYSTAL Kyocera's Kaiterl Philosophy, commitment to continuous ' • - ' • PHOTOVOLTAIC MODULE improvement, is shown by repeatedly achieving world record s "` s „UMW cell efficiencies. ! .� ■. Kyocera Quality Built In: a r OE - New frame technology allows for end mounting with 2400 Pa a 1 . � ■■ w (50 psf) or wind speeds of 130 mph (ASTM E18.30) and V traditional mounting under 5400 Pa (113 psf) to support • w ■ • ' w a a -■ increased snow bad wow.) *mow UV stabilized aesthetically pleasing black anodized frame II - Supported by major mounting structure manufacturers SPECIFICATIONS Easily accessible grounding points on all four corners for fast installation • Physical SpSCIflptlofta ur:..rao Proven junction box technology ■� - Quality locking plug-in connectors to provide safe & - de 030 r whw.) connections - (MOW ' aft NO gi P Kyocera manufactures and assembles solar cells and modules at its own worldwide production sites using a true vertical !' ■ integration process. This superior approach gives Kyocera 3f _g 1, KIY2100X -LPU complete control over every step of the manufacturing process, producing modules with the industry's tightest power tolerance, S , a+1.1 NEC 2008 Compliant promising high quality and efficiency. r r � UL 1703, Class C - Superior Built -In Quality IEC 61215 - Proven Superior Field Performance - Tight Power Tolerance Cate 25 Year Warranty +: - 5 Year Workmanship Warranty - r•rrra Anew) • Specifications •Briar Pwdww.we weer emend 1Sr Lahr. (1T• • Cele McYmn Power Piled 21AV c+svv-01d Number per Module 1 54 Mennen Power V bred sem - •.; r!r� 2 Me.eun Poser Owed O.4rd 7.90A • Mad . Clnrederiesee i:14 - g 1 P � " i t gai Open circa Valve s Ned 5J31t LMperXYN19hXDeptl1 fOr� ei :.aj,I �'7 ?4, 71 w A lit" y� r shw Chid C Current t B.58A AWfit 11101.7b0 j 'rl ..i rrxYrrr'tiiiYli r `T'i�c / ry ---,..,.---...r.........,..------ .. / M er�r�/ r r �' _www�. sw�� e �. u uJ f -. =: M r i , , V"/ Nom! <I rJ 9RS r�rir..+Iw , .....74Iwir_I� r I �/' n • KW Cad! (, r,�fae .+ - - nri -4 r ri iili / - v _ - - - -- S - _ ._ C•■� � /p Aiwa.. Lbelperd d VOC -129x10 Vlt: / ,x.,1:74 ,��YY _ dr i7rs ees�ri� Addendum CosI r �iiiiiri3 iii rii t, rr w =�1� I:- _ �� r /r ri � ii�i ! kMre disc 5.15X10 Arc ■ a r m SOS ar.rrrrr • .. •. -.+/ie :. -.i ot+. rv Jrt / N 1Z ���� / //.IIr►/ Ar %+ri ,r::e 7..".. ■ sio: u.wwrtwuo�+wrr.w.rs LrrgerXYMdhXDeptli �w GS�Nr�ai irr %, rrl- -;.7'; ^r � ZZ. IN /!rl 1i1/ / /!/ { //! .i si s�r � /a llw�a/ /�I ; � � sri - <..i iis/ ir" ' /' . /1 • j / / / /�/ ./,�,�1!' �fI �� %� ,'MGci PCodn MI5 ■ earner Prewr..rw r 11oMan' AEI a ir- /s ill =lY / /yam �/�I /� J % /.l�r %.;'1 / /f! %/ `r r•rdi. / / Alaimo Poser Thad 141•41 141•41 1 11 a/ p<.��l�i /,y.► �rri,� filiiirs .t►ir i�►ii ■Odra Medrew+fbrrvtrip.lv.�i eetV `fire Aran rsttr , / t /1I �t - 7 4 ', / f , II /I I A Machin, • POWC w.dtwf► UNA . — " # : °ii : Ii AK 1I AMU" .' I� /ow Comm tValeg Sow 'owrer.9Tw toc -9o� �. l �*-�w f ! 1 / / Iii,: i �� _ '� � ��/ /� I -- Shod crest Current Pee) eetA dw�nee Fuse to i sA r ifir �, - Aber �r h is ��, ��, iii .,...a...a, ,..�., oR - mr,wrr•r•..e.r .ark ! yy ii/f _ � � �/� ® end �� te.d.nd n...er.d 190 9001 �I 1 — _ . ■ , CaKHOCERa . www.lryocerasolaccom SOLAR by KYOCERA 800-223-9M toll free 800-523-2329 fax . .. � 'Dlr�.� CONFIDENTIAL - THE INFORMATION HEREIN MARKET: MODULES PR[>ag (riNER DESCRIPTION: JOB NUMlll7t ` ���� i CONTAINED SHALL NOT BE USED FOR THE RESI (26) KYOCERA # KD210GX –LPU OLNEY JERRY A OLNEY RESIDENCE JB- 972396 00 NOR SHALL IT BE DISCLOSED IN WHOLE Ce IN / �� BENEFIT OF ANYONE EXCEPT SOLARCITY INC., DESIGN: MOUNTING SYSTEM: 10460 SW 72ND AVE SolarCI L �S SOLARCITY CANOPY –C AND RAIL 5.46 kW ROOF MOUNT PV SYSTE PART TO OTHERS OUTSIDE THE RECIPIENTS DATE ORGANIZATION, EXCEPT IN CONNECTION KITH PROJECT MANAGER: INSERTER: PORTLAND OR 97223 THE SALE AND USE CI THE RESPECTIVE * (1) FRONIUS # IG PLUS 5.0 3/25/2011 3055 Clear ew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE PAGE NAYS SHEET: REV T:(650) 638 I C(sso) 38 - 1029 PERMISSION OF SOLARCITY INC. LEASE 5035457074 CUTSHEETS PV 7 (888)- SOLCITY (765 -2489) I www.solarcity.com INVERTER . INPUT DATA Frain** 10 Plus 8A4 w 8.1 -1 N , 5A -1 w , I eA -1 ew 8-1 ew Ve 4 -1 a rrwr, Recommended PV-Power 2600 -3450 3200 -4400 4260 -6750 5100 -6900 1 7. 6360 -8600 I 10.0 -1 8500 -11600 I 11 9700 -13100 1 1144, 12.04 10200 -13800 a MPPT - Voltage Range 290... 600 V a DC Startup Voltage 246 V Max. Input Voltage CAt too wino 14•r ( - to•q in open octal eperamry 600 V • Nominal Input Current 8.9 A 10.5 A 13,8 A 16.6 A 20.7 A 27.6 A 31.4A 31.4 A 33.1 A Max. usable Input Cun.M 14.0 A 17.8 A 25.4 A 28.1 A 96.1 A 46.7 A 69.5 A 533A 56.1 A 3 Admissible conductor size (DC) No. 14 - 6 AWO - Ntxnber of DC Input Term inak 6 • Max. Current per DC Input Terminal 20 A: Bus bar available for higher input currents OUTPUT DATA Freaks. 10 Plea a.0 -1 1M , 9.0.1 N , 8.0 -1 00 , 6A - ear 7.6 ee0 18.0 - ea 114 - ee, 11.43 j1.0-2,,,, _ Nominal output power (Pao..e) 9000 W 3000 W 6000 W 6000 W 7600 W 9006 W 11400 W 11400 W 12000 'W Mao. continuous output power - E 1 O4'F OM'O) 208 V / 240 V / 277 V 5000 W 3800 W 5000 W 6000 W 7500 W 0995 W 11400 W 11400 W 12000 W = Nominal AO output vo8ags 200V/240V/277V 208V/240V 277 V Operating AC voltage range 208V 185 - 229 V (-12 /.10 %) (default) 240V 211- 264V(- 121 +10 %) i 277 V 244 -305 V ( -12 / +10 %) 3 Max. continuous 208 V 14.4 A 19.3 A 24 0 A 28 B A 56.1 A 48.1 A 54.8 A 31.8 A• no. - output currant 240 V 12.6 A 15.8 A 20 8 A 25 0 A 91.9 A 41.7 A 47.6 A 27.4 A• n.e. 277 V 10.8 A 137 A 18.1 A 21 7 A 27.1 A 36.1 A 41.2A rte. 14.4 A. Admissible oonduotor size (AC) No 14 - 4 AWO Max. continuous W91ty back lead current 0 A _ Nominal output frequency 60 H7 Operating frequency range 59 3 - 60 5 Nz d Total harmonic distortion 3 % Power factor 1 7 GENERAL DATA Erosive 10 Plus I a.0 -1 Yet I a.1 -1 ref I 6.0-1 „ I 6.0-1 ee, I 7.6 -1 ref I 10.0.1 ver I 11.4 -1 1 11.4 -3 e.e. 1 12.0.3 erwn = Max. Efficiency 96 2 % CEC E18oienoy 208 V 95.0 96 95.0 % 96.5 % 96.5 % 56 0 % 95.0 94 55.6 94 96.0 % n.a. E 240 V 96.6% 96.696 96.6% 960% 95 95.5 96 . 0 9 4 96.6 n. a. 9 . z 277 V 96.694 96.696 96.0% 56096 96096 96.6% 96.0% n.a. 96.0% Consumption in standby (night) < 1 W a a Consumption during operation I 8 W I 15 W I 22 W Cooling Controlled forced ventilation, variable fan speed Enclosure Type NEMA 3R = 3 Unit Dimensions (We Hs D) 17.10 24.Bx 0.8 in. 17.1 x 364 x 5.6 in. 171o46.1 x96 in Power Stack Weight 91 lbs. (14 kg) 57 lbs. (26 kg) 82 IDs (37 kg) Wiring Compartment Weight 24 lbs. (11 kg) 26 lbs. (12 kg) 26 lbs. (12 kg) E Admissible ambient operating temperature -4 ... 122x1 ( -20 ... +80eC) _ Compliance 1 UL 1741 - 2005. IEEE 1547.2000 IEEE 1547.1. AN8IAEEE C62.41, FCC Part 15 AS B. NEC Article 69D, C22 2 No. 1071-01 (Sept. 2001) 1 PROTECTION g DEVICES Fronius 10 Plus 3.0 -1 pa, 3.1 -1 an l 8A-1 1e, I 6.04 eel 7.64 vet I 19.0 -1 _, I 114 -1 a 11.4 .8.. 1 12.0 -a r,nn Ground fault protecton internal OFD! (ground Fault Detector /Interrupter); in accordance with UL 1741 -2005 and NEC Art. 690 9 DC reverse polarity protection Internal diode y lalending protection Interna4 in accordance with UL 1741 -2005, IEEE 1647 - 2003 and NEC 2 Over temperature Output power deriding / active cooling _ • per Phase FDl7iu5 Fronius USA LLC Solar Electronic Division 10421 Citation Once. Suite 1100. Brighton. Michigan, 48116 - E -Mail: pv- usclronius.c0m • www.fronlus- uaa.00m e CONFIDENTIAL -THE INFORMATION HERON MARKET: MODULES: PREMISE OWNER: DESCRIP110N: JOB NUMBER: %„id CONTANED SHALL NOT BE USED FOR THE RESI (26) KYOCERA # KD210GX -LPU OLNEY, JERRY A OLNEY RESIDENCE JB- 972396 00 la al N BENEFIT OF IT BE EXCEPT SOLARCITY INC., DESKS MOU SYSTEM: 10460 SW 72ND AVE Pk PART TO OTHERS OUTSIDE IN WHOLE THE RECIPIENTS jS SOLARCITY CANOPY -C AND RAIL 5.46 kW ROOF MOUNT PV SYSTEM DATE i4 S ola ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER INVERTER: PORTLAND, OR 97223 3/25/2011 THE SALE AND USE OF THE RESPECTIVE • (1) FRONIUS # IG PLUS 5.0 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: PAGE NAME SHEET: REV: T:(650) 638-1028 , C 944 638 -1029 PETtMSSKk1 OF soLARaTY INC. LEASE 5035457074 CUTSHEETS PV 8 (888)-50L-CITY (765 -2489) I www.solarcity.com . MOU NTING HARDWARE , I IIII[ 43 ■ 1'� \ \"� APPROVED INSTALLATION METHOD • Roots (brackets) are to be mounted no further RESIDENTIAL SOLAR MOUNTING SYSTEM than 8'apart. • • Rafters must be located- Pilot holes must be drilled into Canopy is the strong, safe, waterproof mounting system for structurally attaching the renter of rafters 1 28 1 2.5 solar panels to composition shingle and wood shake roofs. A715 grade 50 high • Shingle course immediately above penetration shall be cut 2 33 1 3 strength structural steel with durable corrosion resistant coating provides more using provided template to accommodate hashing. 3 43 2 2.5 strength than aluminum and better corrosion resistance than stainless steel. Bracket- • Local wind conditions, exposure, root angle, and position I + 50 2 3 style attachment allows for shingle flashings to completely cover penetrations, of array on roof will determine design wind pressure This chart assumes 15 sq. h or rover per pivot Standard installation of Canopy applies when design wind and minimum 1.5 penetrations per panel. providing excellent long -term waterproofing. pressures are found to be 28pst or lower and requires one ' psi varies m be calculated according to Asa 7-05. 2'h inch lag bolt in the primary position. For all other cases. • Precision engineered brcket geometry provides stiffest see chart to right uplift resistance of any mounting bracket. Rated to 500tH. • --"Th • Flashing is to be inserted under course of shingles above • A715 grade 50 high strength structural steal provides l-------- penetration and pressed down over rout until it snaps roue strength than alumnunr �� into place. • Proven 75 year corrosion resistant hot -dip galvanized .4,110t___,------------- .4,110t___,------------- • Rail is attached with rail locking clamp. t • coating. Laboratory tests show canopy has better corrosion resistance than common stainless steel • Shingle -style flashing completely covers penetration, providing • Flashing 11 better Icing term leak protection than neoprene cone fleshings. Lags and Washers 1 1 • Root- Bracket si • Shingle Flashing locks in place for best water proofing • + 421 • Root-Bracket installed 1 ..' 2x 5/16 lag bolts I 1 • Flashing installed �. - - : t i -: a • 2x 5/16 flat washer I //" s, • 1 i • Rail i ns t a ll e d � ..•• J - - - • • Canopy root precision engineered mounting bracket l` � !` • -_ I w? � illilly i i T�J 8 " OC Max - `` , '� 9 R oo f rafter '`.w \= 9 Rail ' eeitfo �" SOlarCitY. • 888 -SQL -CITY 1 888 - 765 -2489 I WWW.SOLARCITY.COM CONFIDENTIAL — THE "FORMATION HEREIN MARKET: MOOIN.ES: PRIME OWIER: DESCRP110N: NIMIBEIt X10114 . CONTAINED SHALL NOT BE USED FOR NE RESI (26) KYOCERA # KD210GX -LPU OLNEY, JERRY A OLNEY RESIDENCE J B -9 7239 6 00 It„ BEEFIT OF ANYONE EXCEPT SOLARCITY INC., DEM MOWING SYSI 10460 SW 72ND AVE 5.46 kW ROOF MOUNT PV SYSTEM ,' S oiai1 i 1y NOR N SHALL IT BE DISCLOSED" WHOLE OR IN JS SOLARCITY CANOPY -C AND RAIL PART TO OTHERS OUTSIDE THE RECIPIENT'S DATE ORGANIZATION, EXCEPT IN CONNECTION WITH SECT MANAGER INMTER: PORTLAND, OR 97223 3/25/2011 THE SALE AND USE CF THE RESPECTIVE * (1) FRONIUS # IC PLUS 5.0 3055 cleavlew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PATIENT TYPE: PAGE NAME SHEET. REV' T:(650) 3a loz8 I C(650) 638 PERMISSION OF SOLARCITY "` LEASE 5035457074 CUTSHEETS PV 9 (888)- Sa{riY(765 -2489) I www.solarcity.com