Plans NOTES THIS DETAIL REcE TVr r '' ` -- 2 92011 04 MOUNT 135' FIXED TEMPERATURE HEAT DETECTOR TO ` A'T SHAFT WITHIN 18 INCHES OF EACH SPRINKLER HEAD IN CITYOFTIGARD ELEVATOR MACHINE ROOM • ELEVATOR LOBBY OS MOUNT SMOKE DETECTOR WITH AUXILIARY CONTACTS IN BUILDING DIVISION .�.� ELEVATOR LOBBY ON CEILING TO WITHIN 60 INCHES OF 0 ELEVATOR DOOR. ROUTE WIRE TYPICAL. 1 ® ® SHUNT TRIP /FUSED DISCONNECT 11 09 TO ELEVATOR CONTROLLER /DRIVE FOR ELEVATOR RECALL, i 111 SEE WIRING SCHEMATIC. ii �Eil►�►TOR`CAR O 10 TO SHUNT TRIP CONTROL OF ELEVATOR POWER 0)1, © ELEVATOR LOBBY 15 TO FIRE ALARM SYSTEMS SUPERVISED MONITORING CIRCUIT. 1 r T g II 0 0 0 0 ~ �© ° 10 9 T ® TYP ZS SILENT KNIGHT SK4 FIRE ALARM CONTROL PANEL 0 lil PULL STATION 0�� NEV ADDED DEVICES © SMOKE DETECTOR GI ELEVATOR •►] CONTROLLER/ OH HEAT DETECTOR DRIVE ELEVATOR LOBBY ' OR - ❑T TAMPER O O P P ® FLOW o S 1 iF SYSTEM SENSOR SYNCHRONIZED HORN/ADAPTER STROBE — — — — — — — — ( DUCT DETECTOR ELECTRICAL ROOM Li CABLE DESIGNATIONS! p CROSSTICKS INDICATE TYPE AND QUANTITY A = 18/2 FPLR ELEVATOR ELEVATION PLAN o o S, s - 14/2 FPLR m =EXISTING A H (PL) ' NEW LOCATION EXISTING 0 RISER DIAGRAM SYMBOL LIST > le -0 A N ` r DEVICE TYPE GENERAL SUPERVISORY 1ST FLEUR 2ND FLOOR SHUNT 0 ADDRESS(ES) ALARM ALARM RECALL RECALL TRIP 0 I\ 1011 1012 1013 v MANUAL PULLS YES NO PC NO No r lDot ND 00 a) N N STOKE DETECTOR YES Mn NO Mn 3 ' ` 1002 C) WATER FLOW YES MO IO NO NO Z 4C. /Y 1003 LL VALVE TAMPER MD YES MO MO NO Q O O 1004 co ! HEAT DETECTOR YES NO NO NO YES 2 � 0') TT�� 1005 y TEAT DETECTOR YES NO NO MO YES 1006 CITY OF TIGARD N k SMOKE DETECTOR YES PC NO YES No Approved ('t E 11) r SMOKE I DETECTOR YES MI NO YES NO Conditionally Approved . ( ): T 1008 For only the work as described in:�J KE SMO DETECTOR YES No YES NO MO PERMIT NO. I C) s 5 TAI •! N 0 1009 SMOKE DETECTOR YES NO YES NO NO See Letter to: Follow ( ): toto VALVE TAMPER MO YES MI r10 NO c.,,14. Job Addre�ss / J S - C ) - 1 / ^ GOU) t ) 7 T . ( ): ° " Q "` YO 1012 By: M/�\� Date: �:1 �y // DAM MAItO4 S. DUCT DETECTOR YES NO NO NO MO 1013 VALVE TAMPER NO YES NO NO IO 1014 L , .c CF OI IPNfR np fIPPPAT T fINC _ Gtubal Projeu Vatue. SILENT Project Name: Pittman Brooks Standby Hours: 24 KNIGIIT Pro j eetiD: I Alarm Mins:I 5 Prepared By:I KO Derating Factor: _ 1 2 SK -4 Calculations Date: 3,18.2011 Voltage Drop Warning Version 02.25 09 Threshold ,ya :i 10 Max MAC Current: 2.5 Amps Panel ID: I SK -4 Model: SK -4 Fire Alarm Control Panel *Max Panel Current: 3.0 Amps Location: !RISER ROOM Volts: 24 VDC *Maximum panel current can be 6.0 Amps with optional transformer Ckt.# Circuit Name Qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm & Type 1000 Ft. One -Way Ohms EO L SK -4 SK -4 Main Control 1 0.085 0.175 SK -XRM24 110VAC Optional Transfmr. NA NA SK -CAC4 Class Converter Module 0.000 0.000 SK -4XTM Polarity Reversal Module 0.000 0.000 SK -4XZM _ Zone Relay Module 0.000 0.000 SK -4XLM LED Interface Module _ 0.000 0.000 SK -RZA4 Remote Annunciator IDC -1 ELEVATOR / HALLWAY 0.001 0.040 IDC -2 RISER ROOM 0.000 0.040 IDC -3 Initiating Device Ckt 3 _ 0.000 0.000 IDC -4 Initiating Device Ckt 4 0.000 0.000 NAC -1 Notification Appl Ckt 1 0.000 0.000 #18 Stranded 6.39 85 1.09 20.40 0.00% NAC -2 Notification Appl Ckt 2 0.000 0.000 #18 Stranded _ 6.39 15 _ 0.19 20.40 0.00% Non -Rst Pwr Non - Resettable Power 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Reset Pwr Resettable Power 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Total Standby Current (Amps) 0.086 0.255 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 2.057 0.021 Total Alarm AH Required Command Shortcuts Total Combined AH Required 2.08 Multiply By The Derating Factor 1.20 Print Page Minimum Battery AmpHours Required 2.49 Configure Circuits 511.1:\ f x GHT Circuit Configuration Project Name: Pittman Brooks Project ID: 0 Prepared By: KO Date: 3/18/2011 Ckt. Number: IDC -1 Panel ID: SK -4 Ckt. Name: ELEVATOR / HALLWAY Power Limited 40mA Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 System Sensor 2W -B 0.0001 0.0400 0.0001 0.0400 4 System Sensor 2W -B 0.0001 0.0400 0.0005 0.1600 *Unused 0.0000 0.0000 0.0000 0.0000 *Unused 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Totals 0.0006 0.0400 *Refer to Silent Knight Compatibility Document for # of compatible devices per IDC Ckt. Number: IDC -2 Panel ID: SK -4 Ckt. Name: RISER ROOM Power Limited 40mA Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 System Sensor 2W -B 0.0001 0.0400 0.0001 0.0400 User Defined 0.0000 0.0000 0.0000 0.0000 User Defined 0.0000 0.0000 0.0000 0.0000 User Defined 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Totals 0.0001 0 0400 *Refer to Silent Knight Compatibility Document for # of compatible devices per IDC Ckt. Number: IDC-3 Panel ID: SK -4 Ckt. Name: Initiating Device Ckt 3 Power Limited 40mA Qty Device Current Draw Each Current Draw Total _ Standby Alarm Standby Alarm *Unused 0.0000 0.0000 0.0000 0.0000 *Unused 0.0000 0.0000 0.0000 0.0000 *Unused 0.0000 0.0000 0.0000 0.0000 *Unused 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Totals 0.0000 0.0000 *Refer to Silent Knight Compatibility Document for # of compatible devices per IDC SYSTEM $ SENSOR 5600 Series Mechanical Heat Detectors System Sensor's 5600 series mechanical heat detectors .4 offer a low -cost means for property protection against fire, and for non - life - safety installations where smoke detectors are inappropriate. Features Multiple configurations. The 5600 series offers a full -line of • Multiple configurations for installations: configurations to accommodate a broad range of applications. Both - Single and dual circuit models single- and dual - circuit models are available for low- and high - - Fixed temp and combination fixed temp/rate-of-rise temperature ratings with either fixed temperature or combination 135°F or 194 °F ratings. fixed temperature /rate -of -rise (ROR) activation. The ROR element of the fixed /ROR models is restorable to accommodate field- testing. • Plain housing for residential installations (Model 5601 P) • Easy -to -use terminal screws Installation flexibility. To satisfy a variety of installation needs, • A broad range of back box mounting options: the 5600 series easily mounts to single -gang and octagonal back - Single gang boxes. And these models accommodate four- square back boxes, - 3.5" and 4" Octagonal when used with a square to round plaster ring. The reversible - 4 with square to round plaster ring mounting bracket permits both flush- and surface -mount back box installations. • Reversible mounting bracket Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/rate -of -rise units are marked FX/ROR.The 5600 series also provides a post- activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. Agency Listings 41> MEA LISTED APPROVED approved ICI .. i... 199 0 E !2101204.227 Specifications Architectural /Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number , listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single- circuit or a dual - circuit type, normally open. The detector shall be rated for activation at either 135 °F (57 °C) or 194 °F (90 °C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature /rate -of -rise thermal sensor. The rate -of -rise element shall be activated by a rapid rise in temperature, approximately 15 °F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4 -inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14 -22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate -of -rise element of combination fixed temperature /rate -of -rise models shall be restorable, to allow for field- testing.The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical /Operating Specifications Maximum Installation Temperature 5601R 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624:150°F (65.6 ° C) Operating Humidity Range 5 to 95% RH non - condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height 1.69 inches (4.3cm) Alarm Temperature 5601 P, 5603, 5621, and 5623: 135°F (57 5602, 5604, 5622, and 5624: 194°F (90°C) Weight 6 oz (170 grams) Rate -of -Rise Threshold 15 (8.3 ° C) rise per minute (models 5601P, 5602, 5621, and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact Ratings 6-125VAC/ 3A 6- 28VDC /1A 125VDC / 0.3A 250VDC /01 A Input Terminals 14 -22 AWG A r i ' ! I ? ' , � O AM. 'J'4 . Miami 5601P 5602, 5622 5603, 5623 5604, 5624 5621 Ordering Information Identification Method Temperature Model Circuit on Exterior Rating Activation Ut Protected Spacing -10 Foot Ceiling" 5601 P Single None 135°F (57°C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5602 Single Lettering 194 °F (90 °C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 152m) 5603 Single Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194°F (90 °C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 135°F (57°C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 152m) 5622 Dual Lettering 194 °F (90 °C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 Dual Lettering 194 °F (90 °C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) °NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. Sens " + �/ \ �r STErl 3825 Ohio Avenue • St. Charles, IL 60174 µ� a ''2 SysSySensor i'IE 5 S seta le'to3tan9evithoutrutsesiiat session of syste lour om tor Phone: 800-SENSOR2 • •Fax 630-377-6495 c�rert product irkx ranm. 1-0 /0 ev�:t seaustee A05-0.351-002 • 11/06 • rne7E SYSTEM �..�� SENSOR' Photoelectric Smoke Detectors x x System Sensor i series smoke detectors represent significant advancement in conventional detection. The i family is founded on three principles: installation TM ease, intelligence, and instant inspection. Features Installation ease.The i line redefines installation ease with its Plug-in detector line, mounting base included plug -in design. This allows an installer to pre -wire bases (included with heads).The large wire entry port and in -line terminals provide • Large wire entry port ample room for neatly routing the wiring inside the base. The base • In -line terminals with SEMS screws accommodates a variety of back box mounting methods as well as Mounts to octagonal and single gang back boxes, 4-square back direct mounting with drywall anchors. To complete the installation, i • boxes, or direct to ceiling heads plug into the base with a simple Stop -Drop 'N Lock" action. • Stop -Drop 'N Lock attachment to base Intelligence. i detectors offer a number of intelligent features • Removable detector cover and chamber to simplify testing and maintenance. Drift compensation and • Built in remote maintenance signaling smoothing algorithms are standard with the i line to minimize nuisance alarms. 2 -wire P detectors can generate a remote LED- • Drift compensation and smoothing algorithms indicated maintenance signal when connected to the 2W -MOD2 • Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the P Wide angle, dual color LED indication protocol.The SENS -RDR, a wireless device, displays the sensitivityof P • detectors in terms of percent - per -foot obscuration. • Loop testing via EZ Walk feature • Built -in test switch Instant inspection. The i series provides wide -angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out -of- sensitivity, alarm, or freeze trouble. When connected to the 2W -MOD2 loop test/maintenance module or a panel with the i protocol, the EZ Walk loop test feature is available on 2 -wire i detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings MEA MSFM C 01) �S LISTED APPROVED I CI approved approved 091 3011446 7272 - 1653:152 290 -01 -E 2093 3180932 (]j Smoke Detector Specifications Architectural /Engineering Specifications Smoke detector shall be a System Sensor i Series model number , listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W -B, 4W -B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135 °F (57.2°C). The detector shall include a mounting base for mounting to 31/2-inch and 4 -inch octagonal, single -gang, and 4 -inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre - wiring of the base and the head shall be a plug -in type.The detector shall have a nominal sensitivity of 2.5 percent - per -foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual - color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT -B, 4WT-B) conditions. When used in conjunction with the 2W -MOD2 module, 2 -wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24 V non - polarized Minimum: 8.5 V Maximum: 35 V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2 -wire: 50 pA maximum average; 4 -wire: 50 pA maximum average Maximum Alarm Current 2 -wire: 130 mA limited by control panel; 4 -wire: 20 mA @12 V, 23 mA @ 24 V Peak Standby Current 2 -wire: 100 pA; 4 -wire: n/a Alarm Contact Ratings 2 -wire: n /a; 4 -wire: 0.5 A @ 30 V AC/DC Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W -B and 4W -B: 32 °F to 120 °F (0 °C to 49 °C); 2WT-B and 4WT-B: 32 °F to 100 °F (0 °C to 37.8 °C) Operating Humidity Range 0 to 95% RH non- condensing Thermal Sensor 135 °F (57.2 °C) fixed Freeze Trouble 2WT-B and 4WT-B only: 41 °F (5 °C) Sensitivity 2.5 %/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2cinch octagonal back box 4 -inch octagonal back box Single -gang back box 4 -inch square back box with a plaster ring Direct mount to ceiling LED Modes Power -Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W - No 2 -wire 130 mA max. limited by control panel 2WT Yes 2 - wire 130 mA max. limited by control panel 4W - No 4 -wire 20 mA @ 12 V, 23 mA @ 24 V 4WT-B Yes 4 -wire 20 mA @ 12 V, 23 mA @ 24 V Accessories 2W - MOD2 2 - wire loop test / maintenance module RT Removal / replacement tool SENS - RDR Sensitivity reader A77 -AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter T SYSTEM *2009 System Sensor 3825 Ohio Avenue • St. Charles, IL 60174 ?roduc speofxano ssuojec to change withoutnouce. Visit systemsensorcom for SENSOR Phone: 800- SENSOR2 • Fax: 630-377-6495 current product 'n fo rm a°°n,i ndu d 'ng the latest veroonof this °a°sheet A0S -031 &007.6/09 • #2169