Loading...
Plans ,:- / I - :71 , ._,; i.,i. 3 , ,' S-- , ..3 7 CI d ) S' J. c ' (3 .'; 1 .._\__ ..-- , .-.,N '-;/\‘' .5\ • r(-• 5 s .',,,\ c•\ c' k = cy- P\1- c_I : ,...-1v\A -. ) --- s:;:). - z): .-: ) (----') ‘.,_...} i 3 <ICNERI5 ..hc=> 1 A A S Y9 ■ ---, I 1 ' C ! ! F o Q I 0 , I , i_ls) 61 1 - C t CO 37 C)* ., :...,., 04. (3) ,47:::'? r7 eh „ eh ,,317 — - . - - - - -- s 0 I ,-,-) ..,,, ,... ..... "J clg4 W .....* dOV r - k rv , .0,E' .) i IFAT • ,:f-:_ I Z C 2) / ::::1* -••••J ,,, V 4(A M fj) AV JOU ., d, ( ""H „°), L BADGER FIRE PROTECTION FIRE SUPPRESSION SYSTEM ® 300 Tested & Listed UL300 Listed and Tested P/N 9127100 U.L. EX -2458 Component Description • A • ,;',, B TOP OF CENTER OF CYLINDER VALVE DISCHARGE PORT " II 1 2 mm I CYLINDER DIAMETER Figure 2 -1. Dimensions of Cylinder and Valve Assembly, P/N B- 12XXXX Refer to Figure 5 -26 for Cylinder Valve details. Table 2 -1. Cylinder and Valve Assembly Specifications Cylinder and Valve Maximum Dimensions Assembly Number Part Model Flow Number A B C B120001 RG -1.25G 4 15 -1/4 in. 13 -3/4 in. 8 in (387 mm) (349 mm) (203 mm) B120002 RG -2.5G 8 21 in. 19 -5/8 in. 9 in. (534 mm) (498 mm) (230 mm) B120003 RG -4GS 12 19 in. 17 -1/2 in. 12 -1/4 in. (483 mm) (444 mm) (311 mm) B120006 RG -4GM 12 24 -3/8 in. 23 in. 10 in. (619 mm) (584 mm) (254 mm) B120005 RG -6G 18 35 -1/8 in. 33 -3/4 in. 10 in. (892 mm) (857 mm) (254 mm) P/N 9127100 2 -3 September 2006 Component Description • , 2 -1.1.1 CYLINDER BRACKETS H A - ' I CYLINDER STRAP CYLINDER STRAP V I 1 orrimmAttttttom I11111U1111Utlili . r IM11t111Nk al ; ��... 1 'fSIIt 1111 ,._...:. HtII1111111111Ulllittlt tl ( t IIIIlI1HIi111Wl1i I f 0 B B 1 r C „ ) va 1 • n f`" c — 'I FRONT VIEW SIDE VIEW Figure 2 -2. Mounting Brackets Table 2 -2. Mounting Bracket Dimensions Dimensions Part No. Model A B C 9197430 RG -1.25G 3 in. 9 -3/8 in. 1 -3/8 in. (76 mm) (238 mm) (35 mm) 9197263 RG -2.5G 4 -1/2 in. 12 in. 2 -1/2 in. (114mm) (305mm) (64mm) 9197414 RG -4GM 4 -1/2 in. 20 -1/2 in. 2 -1/2 in. (114 mm) (521 mm) (64 mm) 9197415 RG -4GS 4 -1/2 in. 11 -1/2 in. 2 in. (114 mm) (290 mm) (51 mm) September 2006 2 -4 P/N 9127100 Component Description 4 Table 2 -5. Range Guard Nozzles 1 Nozzle Type Part Number Flow Number Grooves ADP Nozzle B120011 1 1 F Nozzle B120012 2 2 { ■ ..., loll sio'jr GRW Nozzle B120013 1 3 R Nozzle B120014 1 4 , olio —11 . L i r___) DM Nozzle B120015 3 0 LPF Nozzle B 120022 2 1 & 4 1 l . i LPR Nozzle B 120024 1 Disc & Core September 2006 2 -8 P/N 9127100 , Component Description 2 -2 CONTROLS 2 -2.1 UNIVERSAL CONTROL HEAD (UCH) Control System, P/N B120099 The UCH Control System, P/N B 120099, is used for actuating the Range Guard Cylinder and Valve Assembly. The UCH Control System can be attached to the System Valve Actuator, P/N B 120042 for direct cylinder mounting, or to a wall for remote mounting. Knockouts are provided to accommodate either type of mounting. The controller can be operated with: • Automatic mechanical detection (fusible -links and thermo -bulb links), • Automatic electrical operation, and • Remote and local manual operation. AL ! 11 1 ) ---- r _________ 1 , _..]:).... ,, 7 7 7 ;3 .- T - , ,,., �' - � I * / 9 -7/16 in. =, . i \ , '"� ` (240 mm) \,1 is I }' \ ).y' i I > \ otr--,-.,:_---- , 0 , , i. 0 , IL,iii , s , i\\ k \L 7 . x ., ..„5, . Iiirge , -;,,,, , • 3 -3/4 in. —. 8 -3/16 in. (95 mm) (208 mm) Figure 2 -14. UCH Control System, P/N B 120099 P/N 9127100 2 -13 September 2006 Component Description 2 -2.3.2 UNIVERSAL -LINK HOUSING KIT, P/N 120064 The Universal -Link Housing Kit, shown in Figure 2 -28, consists of the following: Table 2 -12. Universal Link Housing Kit, P/N 120064 Item Quantity 11 -1/2 in. (292 mm) Detector Housing 1 Crimp Sleeves 2 "S " Hooks 2 The items above are used to attach the Fusible -Link or Thermo -Bulb Links to the 1/16 -inch cable leading to the UCH Control System or A+ Control Box. The Universal -Link Housing can be configured as an End -of -Line or In -Line bracket. 1/16 in. CABLE TO CONTROL SYSTEM (NOT SUPPLIED) "S" HOOKS CRIMP SLEEVE l Zg2 marl THERMO -BULB LINK 1 "1'112.111otioot (NOT SUPPLIED) OR FUSIBLE -LINK i F (NOT SUPPLIED) THERMO -BULB LINK OR FUSIBLE -LINK (NOT SUPPLIED) CRIMP SLEEVE 1/2 in. EMT EXAMPLE OF IN -LINE EXAMPLE OF END -OF -LINE CONNECTOR UNIVERSAL HOUSING KIT UNIVERSAL HOUSING KIT "S" HOOK (NOT SUPPLIED) Figure 2 -28. Example of End -of -line and In -line Universal Link Housing Kit, P/N 120064 P/N 9127100 2 -25 September 2006 Component Description 2 -2.3.3 THERMO -BULB LINKS, P/N B12009X -XXX Thermo -Bulb Links, shown in Figure 2 -29, are used in conjunction with Universal -Link Housing Kits (P/N 120064) and/or Detector Housing Kits (P/N 804548). The links are held together with a liquid - filled glass tube (Thermo - Bulb), which bursts at a predetermined temperature, allowing the two halves of the link to separate. The types of Thermo -Bulb links are: • Rapid Response • Standard Response These Thermo -Bulb links are available in various temperature ratings with a minimum/maximum load rating of 0 lb. /50 lb. (0 kg/23kg) (see Table 2 -13). RAPID RESPONSE STANDARD RESPONSE — \ ,, THERMO -BULB LINK THERMO -BULB LINK C Figure 2 -29. Thermo -Bulb Link, P/N B12009X-XXX Table 2 -13. Rapid and Standard Response Thermo -Bulb Link Temperature Ratings Rapid Response Standard Response Maximum Part Numbers Part Numbers 'I Color Exposure Temperature B120095 -165 B120090 -165 165 ° F (74 °C) Red 100 °F (38 °C) B120095 -212 B120090 -212 212 ° F (100 °C) Green 150 ° F (66 °C) B120095 -286 B120090 -286 286 ° F (141 °C) Blue 225 °F (107 °C) B120095 -360 B120090 -360 360 °F (182 °C) Mauve 300 °F (149 °C) — B120095 -450 B120090 -450 450 °F (232 °C) Black 375 ° F (191 °C) B120095 -500 B120090 -500 500 °F (260 °C) Black 475 °F (246 °C) September 2006 2 -26 P/N 9127100 . Component Description 2 -2.4 Remote Manual Releases 2 -2.4.1 REMOTE MANUAL RELEASE, P/N B875572 (UCH ONLY) The Remote Manual Release, shown in Figure 2 -34, is provided as a means of manually actuating the system from a remote location. The Remote Manual Release is attached to the UCH Control System with 1/16 -inch control cable. To actuate the system at the Remote Manual Release, pull out the safety pin and pull hard on the handle. Each Remote Manual Release is supplied with a separate nameplate. This nameplate must be attached to the mounting surface 1 -inch above or below the Remote Manual Release. i b NOV � , 2006 �.,1 I 1 UT k $ ray '. l lir irviNTri "''ir Tye rd. ; . 8 3-5/8 in. ' z SELF \ (92.2 mm) X- 4® 41 l L ; r.. 1 *)0►�11 0 a 1 . 1 4 v � � * , ,- 1 -1/2 in. (38 mm) Figure 2 -34. Remote Manual Release, P/N B875572 P/N 9127100 2 -31 September 2006 Component Description . • 2 -3.4 Electric Gas Valve, P/N 9197XXX Electric Gas Valve (Figure 2 -41) operates on (12OV, 60 Hz) which powers a solenoid holding the valve open. This valve is controlled by a pressure switch or microswitch and the Manual Reset Relay Box. See Paragraph 2 -3.5. Upon system actuation, the valve closes, stopping the gas flow to the appliance(s). A loss of electrical power will also cause the Electric Gas Valve to close. See Table 2 -18 for a list of the electric gas valve sizes. All Electric Gas Valves must be installed horizontally with the solenoid up. Note: The electric gas valve and the Manual Reset Relay must be specifically UL listed for use with the Range Guard system. SOLENOID ss' a 5 JM'°, }v " Z mei 4 illa " YkF. ,.. I 0 Figure 2 -41. Electric Gas Valve, P/N 9197XXX Table 2 -18. Electric Gas Valve Sizes Size Part Number 1/2 in. (13 mm) 9197017 3/4 in. (19 mm) 9197018 1 in. (25 mm) 9197019 1 -1/4 in. (32 mm) 9197020 1 -1/2 in. (38 mm) 9197021 2 in. (51 mm) 9197022 2 -1/2 in. (64 mm) 9197444 3 in. (76 mm) 9197445 September 2006 2 -38 P/N 9127100 Component Description • • 2 -3.5 Manual Reset Relay for Electric Gas Valve, P/N 9101735 The Manual Reset Relay Box (Figure 2 -42 and Figure 2 -43) provides DPDT contacts rated for 6 amps at 115 Vac and prevents immediate reopening of the Electric Gas Valve (P/N 9197XXX). Figure 2 -43 shows the Manual Reset Relay Box used before 2006. Note: The Electric Gas Valve and the Manual Reset Relay must be specifically UL listed for use with the Range Guard system. POWER ON (l FIRE SYSTEM ELECTRIC GAS VALVE RESET UISTED Figure 2 -42. Manual Reset Relay Box, P/N 9101735 I t f RESET BUTTON ON TOP OF BOX I CAUTION I GAS BURNERS MUST BE IN OFF POSITION BEFORE RESETTING RELAY TURN OFF POWER SOURCE BEFORE REMOVING THIS COVER MANUAL RESET RELAY TYPE RB -2 0 6 AMP, 115 VAC - PILOT DUTY 125 VA 0 k CD Figure 2 -43. Manual Reset Relay Box, P/N 9101735 (Used Before 2006) P/N 9127100 2 -39 September 2006 System Design • 3- 6.1.1.2 Ducts 50 to 100 inches in Perimeter Two ADP nozzles, P/N B120011, pointing in the same direction are required for protection of ducts with perimeters greater than 50 inches and less than or equal to 100 inches. Ducts can be of unlimited length (refer to Figure 3 -30). For other option of ducts up to 75 perimeter inches (See Figure 3 -32). Note: All Range Guard systems are listed by UL for use with the exhaust fan either on or off when the system is discharged. �r— DUCT T HOOD X '/4X 1/2x �I , ,�� %d ' / MAX. DIAMETER 31.83 in. (809 mm) /4X /2X NOZZLES TO BE ALONG ONE 25 mm) E � Q t • CENTERLINE AT THE POINTS. MAX. M SID ID NOOZZLES ES TO TO BE 0 - 6 in. in. (0 -152 mm) UP FROM ENTRANCE OF VERTICAL DUCT MAX. DIAGONAL 11.78 in. (300 mm) MAX. DIAGONAL TYP. (2) ADP NOZZLES 11.78 in. (300 mm) SQUARE RECTANGULAR ROUND ADP NOZZLE 0 to 6 in. (0 to 152 mm) DUCT ENTRANCE C OF VERTICAL DUCT I , - — i ' ' — - OF HORIZONTAL DUCT 14 2 - 4 in. (51 mm - 102 mm) A ADP NOZZLE )11(/ � ` AIM POINT NOZZLE TIP TO DUCT HIP VERTICAUHORIZONTAL DUCT Figure 3 -30. Duct Protection Using Two ADP Nozzles, P/N B120011 September 2006 3 -36 P/N 91927100 System Design . 4 ft. NOZZLE ( 1.2 m) ..., DUCT t/ ,;.. 4 ft . DUCT 1/ d 4 ft. (1.2 m) (1.2 m) .o° 9a'' t '''''' tl .11.';'- .� NOZZLE � (44 1 0 ft. `4 20 ft. (3 m) 74C (6 m) Oft. NOZZLE (1.2 m))/ "V" FILTER BANK COVERAGE "V" FILTER BANK COVERAGE 10 ft. (3 m) PLENUM 20 ft. (6 m) PLENUM NOZZLE a" � 3 /4 H `��� 1 H f "V" FILTER BANK COVERAGE (END VIEW) /� 4 ft. NOZZLE " 1.2 ( m) D c ) '∎ DUCT 1/ DUCT (1.2 m) �, 4 ft. 1/ I. (1.2 m) 7 l I t''''' # iri NOZZLE ,,, � 10 ft. 20 ft. (3 m) /4` O ft. • (6 m) � (1.2 m))/ NOZZLE SINGLE FILTER BANK COVERAGE SINGLE FILTER BANK COVERAGE 10 ft. (3 m) PLENUM 20 ft. (6 m) PLENUM ♦1113 WIf- i 3/4 H d--4.‹.. 0- H ti� I -► I SINGLE BANK FILTER COVERAGE (END VIEW) Figure 3 -28. ADP Protection Nozzle, P/N B120011 September 2006 3 -34 P/N 91927100 System Design • 3 - CYLINDER FLOWS After finding how many nozzles of each type are required for a system, the sum of all the nozzle flow numbers is used to determine the number and size of the cylinders required, in accordance with the cylinder flow number limits given below. Table 3 -30. Cylinder Flow Number Limits Maximum Flow Numbers of Cylinders Cylinder Flow Number RG -1.25G 4 — Single Cylinder Only (cannot manifold) RG -2.5G 8 — Single Cylinder Systems Only (cannot manifold) RG- 4GS/RG4GM Can manifold up to 4 cylinders 1 Cylinder 12 2 Cylinders 24 3 Cylinders 36 4 Cylinders 48 RG -6GS Can manifold up to 2 cylinders' 1 Cylinder 18 2 Cylinders 36 ' Only like cylinders can be manifolded (i.e., four RG -4GS or 4GM; two RG6G) September 2006 3 -42 P/N 91927100 - System Design 3 -4 APPLIANCES Table 3 -1 lists the various appliances and nozzle type used to protect that appliance. Table 3 -1. Appliance References Appliance Reference Nozzle Flow Number Deep Vat Fryer Single Vat Deep Fryer with Drip Boards Paragraph 3 -4.1 F 2 18 -1/2 in. x 24 -1/2 in. Deep Fat Fryer Paragraph 3 -4.2 F 2 Split Vat Deep Fat Fryer Paragraph 3 -4.3 F 2 14 in. x 14 in. (356 mm x 356 mm) Deep Fat Fryer Paragraph 3 -4.4 F 2 Single Vat Deep Fryer with Drip Boards less than 1 in. Paragraph 3 -4.5 F 2 (25 mm) Split Vat Deep Fat Fryer (Low Proximity) Paragraph 3 -4.6 ADP 1 Deep Fat Fryer (Low Proximity) Paragraph 3 -4.7 LPF 2 Krispy Kreme Model 270 d/h Doughnut Fryer Paragraph 3 -4.8 ADP 1 Ranges Four - Burner Range Paragraph 3 -4.9 R 1 Two- Burner Range Paragraph 3 -4.10 R 1 Single Burner Range Paragraph 3 -4.11 R 1 Four -Burner Range Paragraph 3 -4.12 LPR 1 Broilers Upright Broilers Paragraph 3 -4.13 ADP 1 Charbroilers (Lava, Pumice, Ceramic, or Synthetic Rock) Paragraph 3 -4.14 F 2 Gas Radiant/Electric Charbroiler Paragraph 3 -4.15 GRW 1 Natural or Mesquite Charcoal Charbroiler Paragraph 3 -4.16 ADP 1 Mesquite Logs Charbroiler Paragraph 3 -4.17 DM 3 Chain Broiler (Closed -Top) Paragraph 3 -4.18 ADP 1 Chain Broiler (Open -Top) Paragraph 3 -4.19 ADP 1 Griddle - Flat Cooking Surface Paragraph 3 -4.20 ADP 1 Wok Paragraph 3 -4.21 GRW 1 Tilt Skillets (Braising Pans) Paragraph 3 - 4.22 F 2 P/N 91927100 3 -5 September 2006