Specifications
FB4C • LEGACY LINE FAN COIL B r y a n t SIZES 018 THRU 060 Product Data AIR HANDLER TECHNOLOGY AT ITS FINEST The FB4C fan coil combines the proven technology of Bryant fan coil units with Puron ®, the environmentally sound refrigerant, and are loaded with popular features. The design features contoured condensate pans with rugged drain connections, ensuring that little water is left in the unit at the end of the cooling duty cycle. The lack of standing condensate and corrosion free pans improves IAQ and product life, features homeowners appreciate. Standard features include grooved copper tubing and louvered • aluminum fins. Coil circuiting has also been updated to make the most of all Bryant heat pumps and air conditioners. Units come with solid state fan controls, 1 -inch (25mm) thick insulation with R -value of 4.2, multi -speed motors, and fully - wettable coils. Units can accommodate factory- and /or field - installed heaters from 3 to 30 kW. It also should be noted that the unique cabinet design of these fan coils meet new stringent regulations for cabinet air leakage - a requirement of 2% cabinet leakage rate when tested at 1.0 inches of static pressure. The FB4C fan coil design is loaded with popular features. These fan coils utilize the latest in electronic commutation motor (ECM) technology through the use of high efficiency, X -13, blower motors, allowing reliable air delivery with increased static pressure. It comes in a pre - painted (taupe metallic) galvanized steel casing and a factory- supplied power plug for ease of installation. DuraCoat' provides a tin plating of the indoor coil's copper hairpins. This creates a barrier between the corrosion- causing A10083 elements and the coil. All FB4C units are equipped with a piston meter device. STANDARD FEATURES • High efficiency ECM (electronic commutating motor) X -13 motors - all sizes • Integrated motor controls have replaced integrated circuit board • Five available speed tags to meet a wide range of applications • Large, grooved tube, louvered fin coils • Efficient, quiet, time - tested blower housings and diffusers • Sturdy, drainable condensate pans • Cabinet construction features innovations designed to prevent cabinet sweating • Tested for condensate disposal in much tougher conditions than Air Conditioning and Refrigeration Institute requirements • Super -thick R -4.2 insulation with vapor barrier • Pre - painted galvanized steel cabinet (taupe metallic) • Cabinet design meets stringent regulations for 2% cabinet leakage rate when tested at 1.0 inches static pressure • Installation - flexible, multipoise units • Horizontal hanging provisions on cabinet • No tools required to access filter • Newly improved filter rack area filter door insulation added for improved air seal U • Factory - installed heater packages available (5- through 15 -kW) CO • 3- through 30 -kW accessory heaters - field installed u ' • Factory- supplied power plug • Easy plug -in provisions for heater installation • Entry options for high and low voltage wiring hook -up • • Easy coil inspection (removable, snap -in plug on A -coil models) • Leak - preventing sweat connections • Dedicated refrigeration design specific to piston metering device • Designed for manufactured housing applications. ADDITIONAL FEATURES • Factory - installed heater packages available • DuraCoat' coil protection available 2 • MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 • F B 4 C N F 0 1 8 0 0 0 Product Type Heating Size Fan Coil Comfort Series with Puron 00 = No Heat 05 = 5kW Electrical 08 = 8 kW N - 208/230v, 1 ph, 60 Hz 10 = 10kW 15 = 15kW Cabinet Style F - Single Piece Coil Coating 0 = Standard T = DuraCoat'' Capacity 018 = 18,000 024 = 24,000 030 = 30,000 m 036 = 36,000 042 = 42,000 048 = 48,000 060 = 60,000 A lJpPI ISO 9001:2000 rim ...01 CERTIFIED. Pun Use of the AHRl Certified TM y us QM! Mark indicates a manufacturer's n participation in the program For iiif the environmentally sound refrigerant individual products, go to REGISTERED www.ahridirectory.org. DU RACOAT 3 DIMENSIONS ' COIL SHIPPING W1 SHIPPING WT UWT A 8 C D E F G H 3 [OIIf IGURA71011 (LBS) (LBSI SLOPE "A" NON TIN-COATED TIN - COATED FB4CNF018 42 11/16' 14 5/16' 12 1116' 12 5/16• 10 7/16' 18 1/8' 18 5/8' - 12' X - 112 112 754CN7024 42 11 /16' 14 5/16' 12 7/16' 12 5 /16' 10 7/16' 18 1/8' 18 5/8' - 12' X - 112 112 FB4C16030 19 5/8• 17 5/8' 15 3/4' 15 5/8' 15 3/8' 23 1/8' 23 5/8' - 17' X - 122 122 1B4C1F036 49 5/8' 17 5/8' 15 3/4• 15 5/8' 15 3/8' 23 1 /8' 23 5/8' - 17' X - 122 122 FBICNF042 49 5/8' 21 1/8' 19 1/4' 19 1/8' 15 11/16' 23 7/16' 23 1/8' - - - X 157 157 FB4CNF048 49 5/8' 21 1/8' 19 1 /4' 19 1/8' 15 11/16' 23 7/16' 23 1/8' - - - X 157 157 78406060 53 7/16' 21 1/8' 19 1/4' 19 1/8' 19 1/2' 27 1(1' 26 15/16' - - - X 175 175 NOTE: MOTE: ALLON 21• FROM FRONT 1. SERIES DESIGNATION IS THE 11TH POSITION FOR SERVICE OF UNIT PRODUCT NUMBER 2. ALL DIMENSIONS ARE IN 'INCHES' UNLESS NO100. UNIT CONNECTION SIZES SUCTION: 018 8 024 - 5/8' 1.D. SWEAT 22 1/16 030 8 036 - 3/4' 1.D_ SWEAT '� 012 MU 060 - 7/8" I.D. SWEAT X 10 3/16° 11' ll8" LIQUID: 3/8' I.D. SWEAT CONDENSATE: 3/4' FPT I,� 2 1 /8" I 1 OUTLET AIR r 314° ll8 ",1 U I I, � m V - UNIT A /8 3/ 32 °,2'DIA. 6.0. 'S NOTE: MODULAR FOR HIGH VOLTAGE UNITS WILL HAVE ALTERNATE POWER WIRING A TWO-PIECE 718 "DIA. N.O. OPPOSITE SIDE CABINET FOR LOW VOLTAGE e e CONTROL WIRING 7/8', 1 3/32' OPTIONAL FIELD CONVERTED 2' DIA. K.O.'S RIGHT SIDE RETURN OPENING FOR HIGH VOLTAGE (SLOPE COIL UNITS ONLY) POWER WIRING 7/8"DIA. K.O. A - 1 1/2" 1 7/8' FOR LOW VOLTAGE 811 CONTROL WIRING � _ _ _ � 1 15/16' - E 1. o 0 TOP VIEW 1 3/8" d 1 3/16° MAX FOR B 19' MODULAR UNITS 15/16" 1... C —'1 ° DISCONNECT OR 1 3/4' ° CIRCUIT BREAKER LOCATION • e LOWER, CONTROL, L ACCESS 1 1/4" 19 1 2 1/2° RIGHT SIDE VIEW INLET AIR OIL ACCESS /1111 PANEL INLET AIR FIN 2 5/8" 1T Y 4 t1/16' FITTING ill LIQUID LINE CONNECTION E 8 PANEL ° LIQUID LINE e a e / ' LIQUID LINE SUCTION LINE CONNECTION 3 1/16' CO NNE C T I ON CONNECTION !7� o e 1 '�v +' 0 10 7/16' � � . ° V 01 SUCTION LINE O 2 10 3 /4" J CONNECTION • e ° • CO 6 3/16" 9 1 /2' o 0 o •� ® 9 0 5* OPENING PANEL FILTER ACCESS 1' --- I D SLOPE COIL DETAILS ACCESS PANEL CONFIG FOR • INLET AIR CONNECTION LOCATIONS SHOWN SLOPE COILS FOR UPFLOW OR HORIZ. DOWNFLOW OR HORIZ. FRONT VIEW LEFT APPLICATIONS RIGHT A SHOWN WITH 'A' COIL DETAILS CONNECTION "A" COILS LOCATIONS FOR UPFLOW OR HORIZ. APPLICATIONS DOWNFLOW APPLICATIONS A10005 Fig. 1 - FB4CNF - English 4 • DIMENSIONS (cont.) NOTES: 1 . SL0PF COIL 1. CONDENSATE PAN DRAIN CAPS NOT SHOWN FOR CLARITY. 2. ALL DIMENSIONS ARE IN 'INCHES' UNLESS NOTED. AIRFLOW �" 2 3116' TYP T/16" . 1 1 (2 PLACES(. AIRFLOW _ � 12 PLACES TYP ). i I 3 1/4' mililliT 1 ri ' Z 1' TYP. . F ill G PRIMARY DRAI (2 PLACES). 1 1/4• SECONDARY DRAIN i ; i 1 , SECONDARY DRAI PRIMARY DRAI � G L © 2 7/8" `:_:.a - te: , 7/16' TYP. o (2 PLACES). (4 PLACES). DOWNFLOW 2 3/16" 3 1/4. 2 9/16 m LL (FIELD CONVERTED) TYP. (2 PLACES). UPFLOW PRIMARY DRAIN (AS SHIPPED) SECONDARY DRAI r 5/16' PRIMARY DRAI 13/16 TYP. 1 'x{ r 1 1 SECONDARY DRAI 1 • E ---- --f ' \� 0 1 0 1 5/8• I y 1 1/4" �' ) E 1111,1■7 1 TYPE• 1/16' . 1/2 2 1/8" 1 1/4' TYP.+ �'1 7/8• 1/2" 1 13/16' F TYP.• TYP.. 1 1 5/8• TYP. 7/8' 2 7/8" HORIZ. RIGHT TYP • HORIZ. LEFT 5• (FIELD CONVERTED) (AS SHIPPED) it HORIZONTAL MOUNT LOCATIONS - DIMPLES PROVIDED IN TOP PANEL. A-COT1 AND BACK OF CABINET. IN CABINET BOTTOM. HOLES PROVIDED .136" DIA. HORIZONTAL HANGING HARDWARE TO BE FIELD SUPPLIED. PRIMARY DRAIN 1 13/16' • 1 r-- SECONDARY DRAIN TrP LD CD AIRFLOW 8 O O 7/16' TYP. 1 2 3/16' TYP. li AIRFLOW (/ PLACES( 1 l 2 PLACES(. } ! • 1 4 � TYP• 1 1/2' J • 1 1 /8" J 5116' 1 _ TYP• 7/8' 1 3/16' -- T--1" TYP. TYP• T 7/8" ' � (2 PLACES) F 4 3/4 O G HORIZ. LEFT SECONDARY DRAI DRAIN (AS SHIPPED) PRIMARY DRAI 1 31/16 L. 'AINAAY DRAIN PRIMARY DRAIN 5/16' SECONDARY DRAIN } •{ 1 l2 PLACES). y 6 „, IA F ] QO Pi r 'I 0 3' 1/8 n . - �J 1 1/2' :---mm 7/16' TYP, �{ T (4 PLACES). � Z° } }} = T I 3 1/16' 2 11/16' DOWNFLOW L5.1 /e � 1 3/16' J I 1 /2• 2 3/16• J 4 3 /' T 7 /8• TY P.• TYP. (FIELD CONVERTED) (2 PLACES). 1 13/16' 7/8' UPFLOW HORIZ. RIGHT TYP.. (AS SHIPPED) (FIELD CONVERTED) Al 0006 Fig. 2 - FB4CNF - English 5 DIMENSIONS (cont.) ' . COIL SHIPPING WT SHIPPING WT LNT A B C D E F G H J CWt10UAATION (Kgsl (Kgs) SLOPE 'A' NON TIN- COATED T1N- COATED FB4CNF018 1084.3 363.6 315.9 312.8 265.1 460.4 173.1 - 301.8 X - 50.8 50.8 F8406 1084.3 363.6 315.9 312.8 265.1 460.4 413.1 - 301.8 X - 50.8 50.8 FB4CNF030 1260.5 417.7 400.0 396.9 390.5 587.4 600.1 - 431.8 X - 55.3 55.3 F84CNF036 1260.5 447.7 400.0 396.9 390.5 587.4 600.1 - 431.8 X - 55.3 55.3 F13404F042 1260.5 536.6 489.0 485.8 398.5 595.3 587.4 - - - 0 71.2 71.2 FB4CNF048 1260.5 536.6 489.0 485.8 398.5 595.3 587.4 - - - X 77.2 71.2 FB4CNF060 1357.3 536.6 489.0 485.8 495.3 692.2 684.2 - - - 0 79.4 79.4 NOTE: NOTE: ALLOW 533.4 FROM FRONT 1. SERIES DESIGNATION 1S THE 14TH POSITION FOR SERVICE OF UNIT PRODUCT NUMBER 2. ALL DIMENSIONS ARE IN 'MM' UNLESS NOTED. 560.4 O. UNIT CONNECTION SIZES 258.8 - 279.4 X22.2 SUCTION: 018 0 024 - 15.88 1.D. SWEAT 030 A 036 - 19.05 I.D. SWEAT 51.0 r---25.4 OUTLET AfA r 19.0 042 THRU 060 - 22.23 I.D. SWEAT + LIDUID: 9.53 I.D. SWEAT 1 +/ V CONDENSATE: 19.0 FPT 1 } 7 ALTERNATE CO 22.23, 27.78, 50.80 DIA. K.O.'S Ili FOR HIGH VOLTAGE , NOTE: MODULAR ALTERNATE POK WIRING OPPOSITE SIDE 22.23 DIA. N.O. A TWO -PIECE FOR LOW VOLTAGE CABINET CONTROL WIRING 1 ' OPTIONAL FIELD CONVERTED RIGHT SIDE RETURN OPENING (SLOPE COIL UNITS ONLY( 09113 WILL HAVE A 38.1 • e 22.23, 27.78 50.80 DIA. K.O.'S FOR HIGH VOLTAGE POKER WIRING 22.23 DIA. K.O. ° 47.6 FOR OR LOW VOLTAGE 1 CONTROL WIRING I- III A 30.2 MAX H 19.2 25.4 �• 482.6 MODULAR UNITS TOP VIEW 34.9 41.1 -fi B 6 23.8�f C .� 31.8 --.I • OPENING 53 y II 1 163.5 IISCONNECT OR RIGHT SIDE VIEW CIRCUIT BREAKER LOCATION III INLE AI R :LONER, CONTROL, 8 ELECTRIC HEATER ACCESS PANEL OIL ACCESS /111 PANEL INLET A[A 66.7 ri PAN 119.1 FITTING LIDUID LINE CONNECTION E EL ' LIDUID LINE ° • LIQUID LINE ° SUCTION LINE CONNECTION 77.8 CONNECTION CONNECTION • i III 4 265 1 • • ® 0 SUCTION LINE o 273.0 CONNECTION °) 157.2 211 .3 • r � 1.■ iu!� � O • ' r • - , 127.0 FILTER ACCESS 1 4:11111111111111g OPENING PANEL 25.4 --.- 1... D SLOPE COIL DETAILS ACCESS PANEL CONFIG FOR IN CONNECTION LOCATIONS SHOWN SLOPE COILS LET AIR FOR UPFLOW OR HORIZ. DOWNFLOW OR HORIZ. FRONT VIEW LEFT APPLICATIONS RIGHT APPLICATIONS AND SHOWN WITH 'A' COIL DETAILS CONNECTION „A" COILS LOCATIONS FOR UPFLOW OR HORIZ. APPLICATIONS DOWNFLOW APPLICATIONS A10007 Fig. 3 - FB4CNF - Metric 6 . . , DIMENSIONS (cont.) CO: 1. SI 0PF COI! 1. CONDENSATE PAN DRAIN CAPS NOT SHOWN FOR CLARITY. 2. ALL DIMENSIONS ARE IN NM" UNLESS NOTED. 11.1 TYP AIRFLOW AIRFLOW l2 PLACES )� 1 55.6 TYP. - t I (2 PLACES). _ © -1 -25.4 TYP. 82.6 PRIMARY DRAIN (2 PLACES). F G SECONDARY DRAIN 31.8 Ili SECONDARY DRAIN Pr PRIMARY DRAIN © Iii 73.0 25.4 TYP. 11.1 TYP, 1 31.8 12 PLACES). (/ PLACES). 65.1 U 55.6 82 TYP. C DOWNFLOW (2 PLACES). UPFLOW CD (FIELD CONVERTED) (AS SHIPPED) u ' PRIMARY DRAIN SECONDARY DRAT PRIMARY DRAT 16.0 8.0 . r - TYP , SECONDARY DRAIN (i 1 CD !!! 11.3 � 8.0 . �_ 1 iYP 12.7 12.7 51.0 31.8 TYP.. • 22.2 TYP,. 11.3 46.0 TYP.. TYP.. F 22.2 13.0 HORIZ. RIGHT TYP.. HORIZ. LEFT 121.0 (FIELD CONVERTED) (AS SHIPPED) A -COIL . HORIZONTAL MOUNT LOCATIONS • DIMPLES PROVIDED IN TOP PANEL, AND BACK OF CABINET. IN CABINET BOTTOM. HOLES PROVIDED 3.45 DIA. HORIZONTAL HANGING HARDWARE TO BE FIELD SUPPLIED. P r.-- DRAIN 16.0 I SECONDARY DRAT �w • ....._ emE= • AIRFLOW 55.6 TYP. -- O 11.1 TYP. 1 �(2 PLACES) •• PRIMO: ! O • I 1_ AIRFLOW (/ PLACES) i tr' F- tTTPi 2.7 •::- L � - } -�.. i 3b.1 119.2 - B YP � 22.2 30.2 25.1 TYP. F 120.6 •O O G TYP. 200. (2 PLACES) 77.8 SECONDARY DRAIN H O R I Z . LEFT SECONDARY DAAI Li t . (AS SHIPPED) PRIMARY DRAIN • PRIMARY DRAIN 'UNARY DRAIN B.0 SECONDARY DRAIN ,' 0 I TYP.. F • • • •. 1 O I (2 PLACES)• - T . / ,- • I O 1 O 79.1 , r I T r lo. i t ( a 11.1 TY. �1J (4 PLACES). 38.1 I MI } 7 7.8 L68.3 DOWNFLOW • . I T 55.6 120.6 U 9.2 TYP. (FIELD CONVERTED) /6 ° 20°.0 - 2 Ti2.�J 12 PLACES). UPFLOW TYP. 22.2 �{ (AS SHIPPED) HORIZ. RIGHT TYP,. (FIELD CONVERTED) A10008 Fig. 4 - FB4CNF - Metric 7 PHYSICAL DATA , , , • FACTORY DIMENSIONS ORDERING NO. INSTALLED NOMINAL COOLING SHIPPING HEAT (kW) CAPACITY (Btuh) Height Width Depth WEIGHT FB4CNF018(0,T)00 F64CNF018(O,T)05 5 18,000 42 -11/16 in. 14 -5/16 in. 22 -1/16 in. 112 lb 1084mm 363mm 560mm 51 kg FB4CNF018(0,T)08 8 FB4CNF024(0,T)00 - 42 -11/16 in. 14 -5/16 in. 22 -1/16 in. 1121b FB4CNF024(0,T)05 5 24,000 1084mm 363mm 560mm 51 kg FB4CNF024(0,T)10 10 FB4CNF030(0,T)00 - 49 -5/8 in. 17 -5/8 in. 22 -1/16 in. 122 lb FB4CNF030(0,T)08 8 30,000 1260mm 447mm 560mm 55 kg FB4CNF030(0,T)10 10 FB4CNF036(0,T)00 49 -5/8 in. 17 -5/8 in. 22 -1/16 in. 122 lb FB4CNF036(0,T)10 10 36,000 1260mm 447mm 560mm 55 kg FB4CNF036(0,T)15 15 FB4CNF042(0,T)00 - 49 -5/8 in. 21 -1/8 in. 22 -1/16 in. 1571b FB4CNF042(0,T)10 10 42,000 1260mm 536mm 560mm 71 kg -r FB4CNF042(0,T)15 15 m FB4CNF048(0,T)00 - 49 -5/8 in. 21 -1/8 in. 22 -1/16 in. 1571b FB4CNF048(0,T)10 10 48,000 1260mm 536mm 560mm 71 kg FB4CNF048(0,T)15 15 FB4CNF060(0,T)00 - 60 000 53 -7/16 in. 21 -1/8 in. 22 -1/16 in. 1751b FB4CNF060(0,T)15 15 1357mm 536mm 560mm 79 kg SPECIFICATIONS FB4C 18 24 30 36 42 48 60 EVAPORATOR COIL Face Area (sq. ft) 2.23 2.23 2.97 2.97 4.45 4.45 5.93 Configuration Slope Slope Slope Slope A A A Metering Device (Teflon -ring piston) EA52PT061 EA52PT063 EA52PT067 EA52PT070 EA52PT076 EA52PT080 EA52PT090 Puron Refrigerant FILTER* 21- 1 /2 -in 13 -in 16- 3/8 -In 19- 7 /8 -in (546 mm) X (330 mm) (417 mm) (505 mm) BLOWER ASSEMBLY Blower Motor (X -13) HD42AR225 HD44AR240 HD42AR226 HD44AR241 - HD44AR242 HD46AR250 HD46AR251 HP 1/3 1/2 1/3 1/2 1/2 3/4 3/4 CFM 600 800 1000 1200 1400 1600 1750 *Filter must be field - supplied for FB4C units. • 8 Attachment is to roof joist SIDE VIEW i" lag bolt and 1.5" unistrut typical ROOF JOIST threaded rod HEATER 16GA, WIRE • a All- thread Refrigerant Lines Flue Piping Supply Air Duct 41 A/C Coil Drain Pan Return Air duct Condensate Drain y 1 2 Angle Air Filter ii 6 -189.5 APPLIED THERMAL INNOVATION" July, 2009 Gas -Fired Power Vented Unit Heaters Propeller &Blower Models • MODEL HD MODEL HDB n y . < VIiiiiiiiik -•• 'II , k F iii 1 ° F e a c , t ' f MODEL MODEL BDP ODEL PDP INDOOR '!' SOLUTIONS • DESIGN FEATURES - ALL UNITS II/IODINE. INDOORZ SOLUTIONS • Tubular Heat Exchanger Power Vented Unit Power Vented Unit Heater, 150- 400MBH Heaters, 30- 125MBH For commercial or industrial applications that require higher For residential. commercial or industrial applications that requ input ratings, the PDP /BDP is available in ratings that range a low profile unit, Modine offers the Hot Dawg®. Capable of from 150,000 to 400,000 Btu /Hr in either natural or propane gas. being installed just one inch below the ceiling, the superior quality of the Hot Dawg makes it a preferred choice for a Figure 2.3 - Figure 2.4 - variety of applications, including garages and workshops. Propeller Unit Heater Blower Unit Heater Figure 2.1 - Hot Dawg Figure 2.2 - Hot Dawg Propeller Unit Heater Blower Unit Heater .�, i v _------ , /i...s ,,,, ,, : , , � s' ;: Model HD Model HDB Model PDP Model BDP Table 3.1 - Standard Features and Factory Options 1) Model Feature HD HDB PDP BDP Aluminized steel cabinet (gauge indicated) 22 ga. 22 ga. 20 ga. 20 ga. r Low profile casing design d Baked -on polyester powder paint for durability and corrosion resistence • • 0 Adjustable air- deflector blades • L. Fans engineered for quiet operation • Q Totally enclosed fan/blower motors (standard on sizes 100 -400) • • ' C Fingerproof fan guard (optional on PDP units) d Two L- shaped mounting brackets (standard on sizes 30-75, accessory on sizes 100 -125) f i Adjustable mounting brackets for level hanging ra 0 Hinged tool -less bottom pan entry Multi -tap 3 -speed motors, certified to 0.8" W.C. external static pressure • Adjustable motor sheaves, certified to 0.5" W.C. external static pressure • 80% thermally efficient • d ar Aluminized steel heat exchanger (409 stainless steel optional) • CFI C = Tubular heat exchanger • • m = es, burner on each heat exchanger tube for reliable performance, ease of t C serviceability and low sound level on flame ignition/extinction Aluminized steel bumer (409 stainless steel optional) , • CSA certification for commericial and industrial use in the US and Canada • CSA certification for residential use in the US and Canada ,- Factory- installed power exhauster • Controls for natural gas (propane optional) • Single stage gas controls (two stage and mechanical modulation optional) =n High limit safety control 9. Differential pressure switch for proof of venting U Flame roll -out safety switch Direct spark ignition with continuous retry control system i'j Intermittent pilot ignition with continuous retry control system Control terminal board and low voltage terminal connections • Gas control step down transformer with 24V gas controls • Fan delay timer • O See page 13 for Field Installed Accessories 6 -189.5 3 GENERAL PERFORMANCE DATA - MODELS HD & PDP MOD/NE INDOOR I I . SOLUTIONS Table 6.1 - Propeller Unit Model HD and PDP General Performance Data Model HD Sizes Model PDP Sizes 30 45 60 75 100 125 150 175 200 250 300 350 400 • Btu /Hr Input .r 30,000 45,000 60,000 75,000 100,000 125,000 150,000 175,000 200,000 250,000 300,000 350,000 400,000 Btu /Hr Ouput ID 24,000 36,000 48,000 60,000 80,000 100,000 120,000 140,000 160,000 200,000 240,000 280,000 320,000 Entering Airflow (CFM) 505 720 990 1160 1490 1980 2180 2550 2870 3700 4460 4870 5440 @ 70 °F Outlet Velocity (FPM) 523 725 653 769 565 747 931 959 819 1053 1123 1068 1016 Air Temp. Rise ( °F) 44 46 45 48 50 47 51 51 52 50 50 53 54 Max. Mounting 10 10 12 14 12 16 16 17 15 19 21 20 19 Height (Ft.) n Heat Throw (Ft.) @ 25 27 36 38 42 56 55 59 51 67 74 70 69 Max Mtg Ht Motor Type 3; SP SP PSC PSC SP PSC PSC PSC PSC PSC PSC PSC PSC Motor HP 1/15 1/15 1/12 1/12 1/12 1/8 1/8 1/6 1/6 1/3 1/2 3/4 3/4 Motor RPM 1550 1550 1625 1625 1050 1625 1625 1075 1075 1075 1075 1125 1125 Table 6.2 - Propeller Unit Model HD and PDP Operating Electrical Data Supply Model HD Sizes Model PDP Sizes a Power Code Voltage 30 45 60 75 100 125 150 175 200 250 300 350 400 Motor Amps 2.4 2.4 1.2 1.2 2.7 2.2 2.3 2.7 2.7 5.4 7.5 8.8 8.8 115V 01 (115V) Total Amps 3.7 3.7 2.5 2.5 4.7 4.2 4.0 5.1 5.1 7.7 9.8 11.1 11.1 . 1 Phase Transformer kVA n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 01 (115V) with Transformer kVA 0.5 0.5 0.5 0.5 1.0 1.0 0.5 1.0 1.0 1.0 1.5 1.5 1.5 208V Transformer 208V Total Amps 2.05 2.05 1.38 1.38 2.60 2.32 2.21 2.82 2.82 4.26 5.42 6.14 6.14 1 Phase Motor Amps 1.0 1.5 1.5 03 (208V) n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Total Amps 1.9 2.8 2.8 01 (115V) with Transformer kVA 0.5 0.5 0.5 0.5 0.75 0.75 0.5 0.75 0.75 1.0 1.5 1.5 1.5 230V Transformer 230V Total Amps 1.85 1.85 1.25 1.25 2.35 2.10 2.00 2.55 2.55 3.85 4.90 5.55 5.55 1 Phase Motor Amps 1.0 1.5 1.5 2.5 3.5 4.4 4.4 02 (230V) n/a n/a n/a n/a n/a n/a Total Amps 1.9 2.8 2.8 , 3.7 4.7 5.5 5.5 208V 01 (115V) with Transformer kVA 0.5 0.5 0.5 0.5 1.0 1.0 0.5 1.0 1.0 1.0 1.5 1.5 1.5 3 Phase Transformer 208V Total Amps 2.05 2.05 1.38 1.38 2.60 2.32 2.21 2.82 2.82 4.26 5.42 6.14 6.14 230V 01 (115V) with Transformer kVA 0.5 0.5 0.5 0.5 0.75 0.75 0.5 0.75 0.75 1.0 1.5 1.5 1.5 3 Phase Transformer 230V Total Amps 1.85 1.85 1.25 1.25 2.35 2.10 2.00 2.55 2.55 3.85 4.90 5.55 5.55 460V 01 (115V) with Transformer kVA 0.5 0.5 0.5 0.5 0.75 0.75 0.5 0.75 0.75 1.0 1.5 1.5 1.5 3 Phase Transformer 460V Total Amps 0.93 0.93 0.63 0.63 1.18 1.05 1.00 1.28 1.28 1.93 2.45 2.78 2.78 575V 01 (115V) with Transformer kVA 0.5 0.5 0.5 0.5 0.75 0.75 0.5 0.75 0.75 1.0 1.5 1.5 1.5 3 Phase Transformer 575V Total Amps 0.74 0.74 0.50 0.50 0.94 0.84 0.80 1.02 1.02 1.54 1.96 2.22 2.22 , X Ratings shown are for elevations up to 2,000 ft. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. (In Canada see rating plate.) Reduction of ratings requires use of a high altitude kit. ;2 Data taken at 55 °F air temperature rise. At 65F ambient and unit fired at full -rated input. Mounting height as measured from bottom of unit, and without deflector hoods. (a; All motors used are produced. rated and tested by reputable manufacturers in accordance with NEMA standards and carry the standard warranty of both the motor manufacturer and Modine. All motors are 115V single phase motors with built -in thermal overload protection. Model sizes 30 -75 are open motors, sizes 100 -400 are totally enclosed. 6 6 -189.5 DIMENSIONAL DATA - MODEL PDP v ODINE INDOOR a E SOLUTIONS Propeller Units - Model PDP Figure 19.1 - Dimensional Drawings M _ A ...__— C — H --F f DO ie � k —► W I ~ —x ~IC AA i y� F K 1 { . E B 1ji i F 1 ' l i , 1— LL v MODINE BB I - ] i. EE D (OPENING) L (MIN. DISTANCE TO WALL) Table 19.1 - Dimensions (inches) — PDP O Figure 19.2 - Combustible Material and Service Clearances Dimension Model Number Symbol PDP 150 PDP 175 PDP 200 PDP 250 PDP 300 PDP 350 PDP 400 4 A 21 23 -1/2 25 -5/8 25 -5/8 28 -5/8 33 -5/8 40 t B 35 -1/4 35 -1/4 40 -1/4 40 -1/4 40 -1/4 40 -1/4 40 -1/4 C 22 22 25 25 25 25 25 D 18 -9/16 21 -1/16 23 -3/16 23 -3/16 26 -3/16 31 -3/16 37 -1/2 Access i F E 20 20 24 24 24 24 24 Side i F F 12 12 13 -1/2 13 -1/2 14 — — 1 I. -.-By G 6- 9/16 6-9/16 7 -1/2 7 -1/2 7 -1/2 7 -1/2 7 -1/2 i F • • - i 1- H 17 -3/8 19 -7/8 22 22 25 30 36 -3/8 J 0) 5 5 5 6 6 6 6 9o/NE K (Mounting 3/8 -16 3/8 -16 3/8 -16 3/8 -16 3/8 -16 3/8 -16 3/8 -16 + Holes) c.p D L n 35 -13/16 35 -9/16 40 -3/4 40 -3/4 40 -3/4 40 -3/4 44 -3/16 i M 29 -13/16 29- 9116 34 -3/4 34 -3/4 34 -3/4 34- 11/16 38 -3/16 W - - - - - 5 5 x - - ' - - - 16 16 Table 19.2 - Combustible Material AA 8 8 9 9 9 9 9 Clearances O BB 7 -1/4 7 -1/4 7 -1/4 7 -1/4 7 -1/4 7 -1/4 7 -1/4 Access Non - Access Top of Power Model Side Side Top Bottom Exhauster CC — — — — — — — Size (A) (B) (C) (D) (Not shown) DD 2 -3/4 2 -3/4 3-3/8 3 -3/8 3 -3/8 3 -3/8 6-13/16 150-175 1 1 4 12 2 EE 30 -1/2 30 -1/2 32 -7/8 32 -7/8 32 -7/8 32 -7/8 32 -7/8 200 -400 1 1 5 12 3 LL 31 -1/8 31 -1/8 34 -7/8 34 -7/8 36 -1/4 35 -1/2 40-1/2 ,, Provide sufficient room around the heater to allow for Gas Connections ;5 1/2 1/2 1/2 1/2 1/2 3/4 3/4 proper combustion and operation of fan. Free area Fan Diameter 16 18 20 20 22 22 24 around the heater must not be less than 1 -1/2 times Approx. Weight 168 175 239 239 269 338 418 the discharge area of the unit. () Do not use propeller units with duct work. c'', For some models, this is the dimension of the vent transition outlet supplied. © PDP 150 through PDP 300 — 2 holes (and the level hanging adjustment feature). PDP 350 through PDP 400 — 4 holes. (Listed is the hole diameter and threads per inch to accept threaded rod). n, Dimension equals overall plus 6 ". li For natural gas; may vary depending on control availability. 6 -189.5 19